-- ================================================================== -- Copyright (C) 2002 by H3C TECHNOLOGIES. All rights reserved. -- -- Description: This file describes the hw MIB implementation of perormance -- Reference: the content of this file include part description from RFC1757 -- Version: V2.0 -- History: -- v1.0 Created by Qizhenglin, 2002.8.15 -- v1.1 2004-7-6 xiejianping -- merge HUAWEI-RMON-EXT-MIB to HUAWEI-LswPERFORMANCE-MIB and change -- module name from HUAWEI-LswPERFORMANCE-MIB to HUAWEI-RMON-EXT-MIB -- V2.0 2004-10-12 updated by gaolong -- Import from SNMPv2-SMI instead from RFC-1212 -- Import hwInternetProtocol, rmonExtend instead define them in the MIB. -- Change ACCESS to MAX-ACCESS. -- Change value of STATUS from mandatory to current. -- Remove value range from PriAlarmEntry definition. -- Adjust text format of the whole file. -- ================================================================== -- ================================================================== -- -- Varibles and types be imported -- -- ================================================================== HUAWEI-RMON-EXT-MIB DEFINITIONS ::= BEGIN IMPORTS DisplayString FROM RFC1213-MIB OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI OwnerString FROM IF-MIB trapDestEntry, trapDestIndex FROM RMON2-MIB EntryStatus FROM RMON-MIB hwLocal,hwInternetProtocol, rmonExtend FROM HUAWEI-3COM-OID-MIB; -- ================================================================== -- -- ======================= definition begin ========================= -- -- ================================================================== performance MODULE-IDENTITY LAST-UPDATED "200303150000Z" -- March 19, 2003 at 16:05 GMT ORGANIZATION "Hangzhou H3C Tech. Co., Ltd." CONTACT-INFO "Platform Team Hangzhou H3C Tech. Co., Ltd. Hai-Dian District Beijing P.R. China http://www.h3c.com Zip:100085 " DESCRIPTION " " REVISION "200303150000Z" -- March 19, 2003 at 16:06 GMT DESCRIPTION "The initial revision of this MIB module." ::= { rmonExtend 4 } prialarmTable OBJECT-TYPE SYNTAX SEQUENCE OF PriAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of alarm entries." ::= { performance 1 } prialarmEntry OBJECT-TYPE SYNTAX PriAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of parameters that set up a periodic checking for alarm conditions. For example, an instance of the alarmValue object might be named alarmValue.8" INDEX { prialarmIndex } ::= { prialarmTable 1 } PriAlarmEntry ::= SEQUENCE { prialarmIndex INTEGER, prialarmInterval INTEGER, prialarmVariable DisplayString, prialarmSympol DisplayString, prialarmSampleType INTEGER, prialarmValue INTEGER, prialarmStartupAlarm INTEGER, prialarmRisingThreshold INTEGER, prialarmFallingThreshold INTEGER, prialarmRisingEventIndex INTEGER, prialarmFallingEventIndex INTEGER, prialarmStatCycle INTEGER, prialarmStatType INTEGER, prialarmOwner OwnerString, prialarmStatus EntryStatus } prialarmIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic sample at a particular interval for an object on the device." ::= { prialarmEntry 1 } prialarmInterval OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The interval in seconds over which the data is sampled and compared with the rising and falling thresholds. When setting this variable, care should be taken in the case of deltaValue sampling - the interval should be set short enough that the sampled variable is very unlikely to increase or decrease by more than 2^31 - 1 during a single sampling interval. This object may not be modified if the associated alarmStatus object is equal to valid(1)." ::= { prialarmEntry 2 } prialarmVariable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGER (INTEGER, Integer32, Counter32, Counter64, Gauge, or TimeTicks) may be sampled. Because SNMP access control is articulated entirely in terms of the contents of MIB views, no access control mechanism exists that can restrict the value of this object to identify only those objects that exist in a particular MIB view. Because there is thus no acceptable means of restricting the read access that could be obtained through the alarm mechanism, the probe must only grant write access to this object in those views that have read access to all objects on the probe. During a set operation, if the supplied variable name is not available in the selected MIB view, a badValue error must be returned. If at any time the variable name of an established alarmEntry is no longer available in the selected MIB view, the probe must change the status of this alarmEntry to invalid(4). This object may not be modified if the associated alarmStatus object is equal to valid(1)." ::= { prialarmEntry 3 } prialarmSympol OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { prialarmEntry 4 } prialarmSampleType OBJECT-TYPE SYNTAX INTEGER { absoluteValue(1), deltaValue(2), speedValue(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The method of sampling the selected variable and calculating the value to be compared against the thresholds. If the value of this object is absoluteValue(1), the value of the selected variable will be compared directly with the thresholds at the end of the sampling interval. If the value of this object is deltaValue(2), the value of the selected variable at the last sample will be subtracted from the current value, and the difference compared with the thresholds. This object may not be modified if the associated alarmStatus object is equal to valid(1)." ::= { prialarmEntry 5 } prialarmValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the statistic during the last sampling period. For example, if the sample type is deltaValue, this value will be the difference between the samples at the beginning and end of the period. If the sample type is absoluteValue, this value will be the sampled value at the end of the period. This is the value that is compared with the rising and falling thresholds. The value during the current sampling period is not made available until the period is completed and will remain available until the next period completes." ::= { prialarmEntry 6 } prialarmStartupAlarm OBJECT-TYPE SYNTAX INTEGER { risingAlarm(1), fallingAlarm(2), risingOrFallingAlarm(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The alarm that may be sent when this entry is first set to valid. If the first sample after this entry becomes valid is greater than or equal to the risingThreshold and alarmStartupAlarm is equal to risingAlarm(1) or risingOrFallingAlarm(3), then a single rising alarm will be generated. If the first sample after this entry becomes valid is less than or equal to the fallingThreshold and alarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingAlarm(3), then a single falling alarm will be generated. This object may not be modified if the associated alarmStatus object is equal to valid(1)." ::= { prialarmEntry 7 } prialarmRisingThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "A threshold for the sampled statistic. When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval was less than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is greater than or equal to this threshold and the associated alarmStartupAlarm is equal to risingAlarm(1) or risingOrFallingAlarm(3). After a rising event is generated, another such event will not be generated until the sampled value falls below this threshold and reaches the alarmFallingThreshold. This object may not be modified if the associated alarmStatus object is equal to valid(1)." ::= { prialarmEntry 8 } prialarmFallingThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "A threshold for the sampled statistic. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is less than or equal to this threshold and the associated alarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingAlarm(3). After a falling event is generated, another such event will not be generated until the sampled value rises above this threshold and reaches the alarmRisingThreshold. This object may not be modified if the associated alarmStatus object is equal to valid(1)." ::= { prialarmEntry 9 } prialarmRisingEventIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The index of the eventEntry that is used when a rising threshold is crossed. The eventEntry identified by a particular value of this index is the same as identified by the same value of the eventIndex object. If there is no corresponding entry in the eventTable, then no association exists. In particular, if this value is zero, no associated event will be generated, as zero is not a valid event index. This object may not be modified if the associated alarmStatus object is equal to valid(1)." ::= { prialarmEntry 10 } prialarmFallingEventIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The index of the eventEntry that is used when a falling threshold is crossed. The eventEntry identified by a particular value of this index is the same as identified by the same value of the eventIndex object. If there is no corresponding entry in the eventTable, then no association exists. In particular, if this value is zero, no associated event will be generated, as zero is not a valid event index. This object may not be modified if the associated alarmStatus object is equal to valid(1)." ::= { prialarmEntry 11 } prialarmStatCycle OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { prialarmEntry 12 } prialarmStatType OBJECT-TYPE SYNTAX INTEGER{ forever(1), during(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { prialarmEntry 13 } prialarmOwner OBJECT-TYPE SYNTAX OwnerString MAX-ACCESS read-write STATUS current DESCRIPTION "The entity that configured this entry and is therefore using the resources assigned to it." ::= { prialarmEntry 14 } prialarmStatus OBJECT-TYPE SYNTAX EntryStatus MAX-ACCESS read-write STATUS current DESCRIPTION "The status of this alarm entry." ::= { prialarmEntry 15 } hwrmonEnableTable OBJECT-TYPE SYNTAX SEQUENCE OF HwrmonEnableTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of enable rmon entries." ::= { rmonExtend 5 } hwrmonEnableTableEntry OBJECT-TYPE SYNTAX HwrmonEnableTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of parameters that set up a hwrmonEnableTable" INDEX { hwrmonEnableIfIndex } ::= { hwrmonEnableTable 1 } HwrmonEnableTableEntry ::= SEQUENCE { hwrmonEnableIfIndex INTEGER, hwrmonEnableStatus INTEGER } hwrmonEnableIfIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Specify an interface to enable rmon." ::= { hwrmonEnableTableEntry 1 } hwrmonEnableStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specify an interface to enable rmon." ::= { hwrmonEnableTableEntry 2 } hwTrapDestTable OBJECT-TYPE SYNTAX SEQUENCE OF HWTrapDestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the trap destination Extend Table for providing, via SNMP, the capability of configure a trap dest." ::= { rmonExtend 6 } hwTrapDestEntry OBJECT-TYPE SYNTAX HWTrapDestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines an entry in the hwTrapDestTable." AUGMENTS { trapDestEntry } ::= { hwTrapDestTable 1 } HWTrapDestEntry ::= SEQUENCE { hwTrapDestVersion INTEGER } hwTrapDestVersion OBJECT-TYPE SYNTAX INTEGER { snmpv1(1), snmpv2(2), snmpv3andauthen(3), snmpv3andnoauthen(4), snmpv3andpriv(5) } MAX-ACCESS read-create STATUS current DESCRIPTION "The version for trap destination. This object may not be modified if the associated trapDestStatus object is equal to active(1)." DEFVAL { snmpv1 } ::= { hwTrapDestEntry 1 } -- extend from Remote Network Monitoring Traps rmonExtendEventsV2 OBJECT-IDENTITY STATUS current DESCRIPTION "Definition point for pri RMON notifications." ::= { rmonExtend 0 } pririsingAlarm NOTIFICATION-TYPE OBJECTS { prialarmIndex, prialarmSympol, prialarmSampleType, prialarmValue, prialarmRisingThreshold } STATUS current DESCRIPTION "The SNMP trap that is generated when an alarm entry crosses its rising threshold and generates an event that is configured for sending SNMP traps." ::= { rmonExtendEventsV2 1 } prifallingAlarm NOTIFICATION-TYPE OBJECTS { prialarmIndex, prialarmSympol, prialarmSampleType, prialarmValue, prialarmFallingThreshold } STATUS current DESCRIPTION "The SNMP trap that is generated when an alarm entry crosses its falling threshold and generates an event that is configured for sending SNMP traps." ::= { rmonExtendEventsV2 2 } END