-- ============================================================================= -- Copyright (c) 2004-2015 Hangzhou H3C Tech. Co., Ltd. All rights reserved. -- -- Description: -- This MIB module is for configuring and monitoring Fibre Channel -- over Ethernet (FCoE) related entities. -- Reference: -- Version: V1.2 -- History: -- V1.0 created by h06247 -- V1.1 Added h3cFCoEFIPSnoopingTable by zhangchangjun 02876. -- Modified the range of h3cFCoECfgDATov by wangyuqiang 08530. -- V1.2 Added h3cFCoEVlanCfgTable by chengzhipeng 04378 2014-05-09 -- Modified the range of h3cFCoECfgDATov by chengzhipeng 04378. -- Added h3cFCoEFIPSnoopingFCFTable, h3cFCoEFIPSnoopingENodeTable, -- h3cFCoEFIPSnoopingVNTable and h3cFCoEFIPSnoopingIfCfgTable by -- h06247 2014-11-12 -- ============================================================================= H3C-FCOE-MIB DEFINITIONS ::= BEGIN IMPORTS h3cCommon FROM HUAWEI-3COM-OID-MIB MODULE-IDENTITY, OBJECT-TYPE, Unsigned32 FROM SNMPv2-SMI -- [RFC2578] RowStatus, TimeStamp, TruthValue, MacAddress, TEXTUAL-CONVENTION FROM SNMPv2-TC -- [RFC2578] SnmpAdminString FROM SNMP-FRAMEWORK-MIB -- [RFC3411] InterfaceIndex, InterfaceIndexOrZero FROM IF-MIB -- [RFC2863] VlanIndex FROM Q-BRIDGE-MIB -- [RFC4363] T11FabricIndex FROM T11-TC-MIB -- [RFC4439] fcmInstanceIndex FROM FC-MGMT-MIB -- [RFC4044] H3cFcNameId FROM H3C-FC-TC-MIB; h3cFCoE MODULE-IDENTITY LAST-UPDATED "201411120000Z" ORGANIZATION "Hangzhou H3C Technologies Co., Ltd." CONTACT-INFO "Platform Team Hangzhou H3C Technologies Co., Ltd. Hai-Dian District Beijing P.R. China http://www.h3c.com Zip: 100085" DESCRIPTION "This MIB module is for configuring and monitoring Fibre Channel over Ethernet (FCoE) related entities. This MIB defines a Virtual FC (VFC) Interface as an object that represents either a VF_Port or a VE_Port on an FCoE Forwarder (FCF). VFC interfaces can be created either statically (by management request) or dynamically (at the time of FIP based FLOGI or ELP request). Other terminologies used in this MIB are defined by the H3c FCoE standard, as defined in the FC-BB-5 specification. This MIB also supports configuration of the following objects: - Mapping of FCoE VLAN-ID used to carry traffic for a Fabric - FC-MAP value used by the FCF operating in FPMA mode - FIP snooping related objects" REVISION "201411120000Z" DESCRIPTION "Added h3cFCoEFIPSnoopingFCFTable, h3cFCoEFIPSnoopingENodeTable h3cFCoEFIPSnoopingVNTable and h3cFCoEFIPSnoopingIfCfgTable." REVISION "201203280000Z" DESCRIPTION "Initial version of this MIB module." ::= { h3cCommon 120 } h3cFCoEObjects OBJECT IDENTIFIER ::= { h3cFCoE 1 } h3cFCoEConfig OBJECT IDENTIFIER ::= { h3cFCoEObjects 1 } H3cFCoEVfcBindType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Defines the different methods to identify (or bind to) - the ENode associated with a particular VF_Port VFC - the remote-FCF associated with a particular VE_Port VFC interfaceIndex(1) - This type is used only when an ENode or remote-FCF is directly connected to the local FCF via one of the local Ethernet interfaces, in which case the value contains the ifIndex of said Ethernet interface. macAddress(2) - This type is used when an ENode or remote-FCF is reachable from the local FCF over a (Layer-2) Ethernet network. A FIP frame from an ENode or remote-FCF is associated to a VFC only if the frame's source MAC address is the same as the MAC Address bound on that VFC." SYNTAX INTEGER { interfaceIndex(1), macAddress(2) } -- -- FCoE Globals per Switch in a Fibre Channel Management Instance -- Fibre Channel Management instance is defined in [RFC4044] as a -- separable managed instance of Fibre Channel functionality. -- Fibre Channel functionality may be grouped into Fibre -- Channel management instances in whatever way is most -- convenient for the implementation(s). -- -- RFC4044 also defines the fcmSwitchTable as a table of -- information about Fibre Channel switches which are managed -- by Fibre Channel management instances. Each Fibre Channel -- management instance can manage one or more Fibre Channel -- switches. The Switch Index, fcmSwitchIndex, is -- IMPORTed from the FC-MGMT-MIB as the index value -- to uniquely identify a Fibre Channel switch amongst -- those (one or more) managed by the same Fibre -- Channel management instance. -- In this MIB, the same fcmSwitchIndex is used to -- identify each FCF and to distinguish it from other -- FCFs and from other Fibre Channel switches. -- -- h3cFCoECfgTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cFCoECfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table facilitates configuration of FCoE parameters on a per Fibre Channel management instance." ::= { h3cFCoEConfig 1 } h3cFCoECfgEntry OBJECT-TYPE SYNTAX H3cFCoECfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "There is one entry in this table for each Fibre Channel management instance." INDEX { fcmInstanceIndex } ::= { h3cFCoECfgTable 1 } H3cFCoECfgEntry ::= SEQUENCE { h3cFCoECfgFcmap OCTET STRING, h3cFCoECfgDynamicVfcCreation TruthValue, h3cFCoECfgDefaultFCFPriority Unsigned32, h3cFCoECfgDATov Unsigned32, h3cFCoECfgAddressingMode INTEGER } h3cFCoECfgFcmap OBJECT-TYPE SYNTAX OCTET STRING (SIZE (3)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object configures the FC-MAP value used by the FCF when operating in FPMA mode. The default value is 0EFC00h, as written in the standard." REFERENCE "Fibre Channel - Backbone - 5 (FC-BB-5), section 7.6 and table 47" DEFVAL { '0EFC00'h } ::= { h3cFCoECfgEntry 1 } h3cFCoECfgDynamicVfcCreation OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object is set to 'true' to enable, or 'false' to disable, the dynamic creation of VFC interfaces on this FCF. When set to 'true', VFC interfaces are dynamically created as and when a FIP-based FLOGI or ELP request is received." DEFVAL { false } ::= { h3cFCoECfgEntry 2 } h3cFCoECfgDefaultFCFPriority OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The FIP priority value advertised by the FCF to ENodes by default. h3cFCoEStaticVfcFCFPriority configured for a VFC interface overrides this setting for the ENode associated with the VFC." DEFVAL { 128 } ::= { h3cFCoECfgEntry 3 } h3cFCoECfgDATov OBJECT-TYPE SYNTAX Unsigned32 (4..600) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "The Discovery_Advertisement_Timeout value configured for the FCF. This is used as the timeout value in seconds by the FCF to send periodic Discovery Advertisements." DEFVAL { 8 } ::= { h3cFCoECfgEntry 4 } h3cFCoECfgAddressingMode OBJECT-TYPE SYNTAX INTEGER { fpma(1), spma(2), fpmaAndSpma(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Addressing mode(s) supported by the FCF. Implementations should fail SetRequests for unsupported modes." ::= { h3cFCoECfgEntry 5 } h3cFCoEVLANTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cFCoEVLANEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "In fabrics in which VLANs are deployed, this table facilitates configuration of VLAN and Virtual Fabric associations in an FCoE network. In such fabrics, FCoE forwarding for a fabric is over a VLAN in a (Layer-2) Ethernet network. That is, reachability between the ENode/remote-FCF and an FCF for a given fabric is determined by the reachability provided by the Ethernet network on the corresponding VLAN. An active entry in this table indicates which VLAN is used to transport FCoE traffic for a particular Virtual Fabric. If VLANs are not deployed or not enabled, entries in this table are ignored by the bridge. Some implementations may allow traffic from only one Virtual Fabric to be transported over a given VLAN. Such implementations should prevent multiple entries with the same VLAN-ID from being created in this table. Modifying existing VLAN-Virtual Fabric associations is not possible. The specific row must first be deleted and then a new one created." ::= { h3cFCoEConfig 2 } h3cFCoEVLANEntry OBJECT-TYPE SYNTAX H3cFCoEVLANEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "There is one entry in this table for each VLAN that is designated to transport FCoE traffic for a given Virtual Fabric." INDEX { fcmInstanceIndex, h3cFCoEVLANIndex, h3cFCoEFabricIndex } ::= { h3cFCoEVLANTable 1 } H3cFCoEVLANEntry ::= SEQUENCE { h3cFCoEVLANIndex VlanIndex, h3cFCoEFabricIndex T11FabricIndex, h3cFCoEVLANOperState INTEGER, h3cFCoEVLANRowStatus RowStatus } h3cFCoEVLANIndex OBJECT-TYPE SYNTAX VlanIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the VLAN-ID that the FCoE FCF function is being enabled for." ::= { h3cFCoEVLANEntry 1 } h3cFCoEFabricIndex OBJECT-TYPE SYNTAX T11FabricIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the Fabric Index of the Virtual Fabric traffic which is to be transported over the VLAN identified by h3cFCoEVLANIndex." ::= { h3cFCoEVLANEntry 2 } h3cFCoEVLANOperState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Operational state of this VLAN-Virtual Fabric association entry. The 'up' state is achieved when both the Virtual Fabric and VLAN are valid." ::= { h3cFCoEVLANEntry 3 } h3cFCoEVLANRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this conceptual row. The RowStatus becomes active on successful creation of an entry." ::= { h3cFCoEVLANEntry 4 } h3cFCoEStaticVfcTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cFCoEStaticVfcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table facilitates the creation and deletion of static VFC interfaces. While VFCs can be dynamically created based on FIP FLOGI/ELP requests, operators may want to associate certain pre-configured policy for a particular ENode or a remote-FCF. In such cases static VFC creation becomes necessary. In addition to being creating, a static VFC also needs to be associated to an ENode or remote-FCF. The VFC binding provides such an association. The binding does not need to be specified when the row for a VFC is created, but may be specified later." ::= { h3cFCoEConfig 3 } h3cFCoEStaticVfcEntry OBJECT-TYPE SYNTAX H3cFCoEStaticVfcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "There is one entry in this table for each statically created VFC Interface." INDEX { fcmInstanceIndex, h3cFCoEStaticVfcIndex } ::= { h3cFCoEStaticVfcTable 1 } H3cFCoEStaticVfcEntry ::= SEQUENCE { h3cFCoEStaticVfcIndex Unsigned32, h3cFCoEStaticVfcFCFPriority Unsigned32, h3cFCoEStaticVfcBindType H3cFCoEVfcBindType, h3cFCoEStaticVfcBindIfIndex InterfaceIndexOrZero, h3cFCoEStaticVfcBindMACAddress MacAddress, h3cFCoEStaticVfcIfIndex InterfaceIndex, h3cFCoEStaticVfcCreationTime TimeStamp, h3cFCoEStaticVfcFailureCause SnmpAdminString, h3cFCoEStaticVfcRowStatus RowStatus } h3cFCoEStaticVfcIndex OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This index uniquely identifies a static VFC entry in this table." ::= { h3cFCoEStaticVfcEntry 1 } h3cFCoEStaticVfcFCFPriority OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "If this VFC is for a VF_Port this object is used to configure FCF priority to be advertised to the ENode associated with the VFC." DEFVAL { 128 } ::= { h3cFCoEStaticVfcEntry 2 } h3cFCoEStaticVfcBindType OBJECT-TYPE SYNTAX H3cFCoEVfcBindType MAX-ACCESS read-create STATUS current DESCRIPTION "The mechanism to identify the ENode associated with this VFC if it is of type VF_Port or to identify the remote-FCF associated with this VFC if it is of type VE_Port." ::= { h3cFCoEStaticVfcEntry 3 } h3cFCoEStaticVfcBindIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-create STATUS current DESCRIPTION "This object is applicable only when the local FCF is directly connected to an ENode or remote-FCF over a specific Ethernet interface, in which case this object contains the ifIndex of said Ethernet interface. If the ENode or remote-FCF is not directly connected to the FCF, this value of this object is zero." ::= { h3cFCoEStaticVfcEntry 4 } h3cFCoEStaticVfcBindMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This object is applicable when the ENode or remote-FCF to which the local FCF is connected is identified by a MAC address. A FIP frame from an ENode or remote-FCF is associated with this VFC only if the source MAC address in the frame is the same as the value of this object." ::= { h3cFCoEStaticVfcEntry 5 } h3cFCoEStaticVfcIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex of this Virtual FC interface." ::= { h3cFCoEStaticVfcEntry 6 } h3cFCoEStaticVfcCreationTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The timestamp of this entry's creation time." ::= { h3cFCoEStaticVfcEntry 7 } h3cFCoEStaticVfcFailureCause OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The cause of failure for the last bind operation. This object will be zero length if and only if the bind is successful." ::= { h3cFCoEStaticVfcEntry 8 } h3cFCoEStaticVfcRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this conceptual row. The RowStatus becomes active on successful creation of a VFC. The VFC does not need to be bound for the row to be active, but the VFC must be bound before becoming operational." ::= { h3cFCoEStaticVfcEntry 9 } -- -- FIP Snooping related objects used to configure FIP Snooping -- on a (FIP-aware) Ethernet Bridge -- h3cFCoEFIPSnoopingTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cFCoEFIPSnoopingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "FCoE provides increased flexibility, but with this flexibility new challenges arise in assuring highly robust Fabrics. The FCF does not have the complete control that a Fibre Channel switch has. Ethernet bridges commonly provide a feature called Access Control Lists (ACLs). Properly configured ACLs may emulate a point-to-point link by providing the traffic enforcement previously discussed. Furthermore, the FIP protocol has been designed to enable Ethernet bridges to efficiently monitor FIP frames passing through them. This data facilitates the automatic configuration of these ACLs. In addition, the automatic configuration is possible independent of any other ACLs that may be in use in the network for other applications. And FIP Snooping is to maintain these ACLs." ::= { h3cFCoEConfig 4 } h3cFCoEFIPSnoopingEntry OBJECT-TYPE SYNTAX H3cFCoEFIPSnoopingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "There is one entry in this table for each VLAN that is designated to ensure that only valid FCoE traffic is allowed." INDEX { fcmInstanceIndex, h3cFCoEFIPSnoopingVLANIndex } ::= { h3cFCoEFIPSnoopingTable 1 } H3cFCoEFIPSnoopingEntry ::= SEQUENCE { h3cFCoEFIPSnoopingVLANIndex VlanIndex, h3cFCoEFIPSnoopingEnable TruthValue, h3cFCoEFIPSnoopingFcmap OCTET STRING } h3cFCoEFIPSnoopingVLANIndex OBJECT-TYPE SYNTAX VlanIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the VLAN-ID that the FIP Snooping function is being enabled for." ::= { h3cFCoEFIPSnoopingEntry 1 } h3cFCoEFIPSnoopingEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to enable or disable FIP Snooping on an Ethernet Bridge." DEFVAL { false } ::= { h3cFCoEFIPSnoopingEntry 2 } h3cFCoEFIPSnoopingFcmap OBJECT-TYPE SYNTAX OCTET STRING (SIZE (3)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object configures the FC-MAP value associated with the FIP snooping Ethernet Bridge." DEFVAL { '0EFC00'h } ::= { h3cFCoEFIPSnoopingEntry 3 } -- VLAN FCoE Configuration h3cFCoEVlanCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cFCoEVlanCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table contains FCoE related configurations and information of VLANs. An entry in this table is created when the corresponding VLAN is created and FCoE is enabled for the VLAN, as well as deleted when the VLAN is deleted or FCoE is disabled for the VLAN. If the switch mode is not FCF-NPV mode, all the operations on any object in this table result in errors." ::= { h3cFCoEConfig 5 } h3cFCoEVlanCfgEntry OBJECT-TYPE SYNTAX H3cFCoEVlanCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry used for managing the FCoE related configurations of a VLAN." INDEX { h3cFCoEVLANIndex } ::= { h3cFCoEVlanCfgTable 1} H3cFCoEVlanCfgEntry ::= SEQUENCE { h3cFCoEVlanCfgFcmap OCTET STRING, h3cFCoEVlanCfgFCFPriority Unsigned32, h3cFCoEVlanCfgDATov Unsigned32, h3cFCoEVlanCfgRowStatus RowStatus } h3cFCoEVlanCfgFcmap OBJECT-TYPE SYNTAX OCTET STRING (SIZE (3)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object configures the FC-MAP value used by the FCF in a VLAN when operating in FPMA mode. If this object is not configured, the default value is 0EFC00h." DEFVAL { '0EFC00'h } ::= { h3cFCoEVlanCfgEntry 1 } h3cFCoEVlanCfgFCFPriority OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "The FIP priority value advertised by the FCF in a VLAN to ENodes by default. If this object is not configured, the default value is 128." DEFVAL { 128 } ::= { h3cFCoEVlanCfgEntry 2 } h3cFCoEVlanCfgDATov OBJECT-TYPE SYNTAX Unsigned32 (4..600) UNITS "seconds" MAX-ACCESS read-create STATUS current DESCRIPTION "The Discovery_Advertisement_Timeout value configured for the FCF in a VLAN. This is used as the timeout value in seconds by the FCF in a VLAN to send periodic Discovery Advertisements. If this object is not configured, the default value is 8." DEFVAL { 8 } ::= { h3cFCoEVlanCfgEntry 3 } h3cFCoEVlanCfgRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Now only three states are supported: createAndGo, active, and destroy." ::= { h3cFCoEVlanCfgEntry 4 } -- FIP Snooping FCF information h3cFCoEFIPSnoopingFCFTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cFCoEFIPSnoopingFCFEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table contains the remote FCF information on device." ::= { h3cFCoEConfig 6 } h3cFCoEFIPSnoopingFCFEntry OBJECT-TYPE SYNTAX H3cFCoEFIPSnoopingFCFEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains information about a FCF for a VLAN." INDEX { fcmInstanceIndex, h3cFCoEFIPSnoopingFCFVLANIndex, h3cFCoEFIPSnoopingFCFIfIndex, h3cFCoEFIPSnoopingFCFMAC } ::= { h3cFCoEFIPSnoopingFCFTable 1 } H3cFCoEFIPSnoopingFCFEntry ::= SEQUENCE { h3cFCoEFIPSnoopingFCFVLANIndex VlanIndex, h3cFCoEFIPSnoopingFCFIfIndex InterfaceIndex, h3cFCoEFIPSnoopingFCFMAC MacAddress, h3cFCoEFIPSnoopingFCFSwitchName H3cFcNameId, h3cFCoEFIPSnoopingFCFFabricName H3cFcNameId, h3cFCoEFIPSnoopingFCFENodeCount Unsigned32 } h3cFCoEFIPSnoopingFCFVLANIndex OBJECT-TYPE SYNTAX VlanIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the VLAN-ID whose FIP Snooping function gets ready on the FCF." ::= { h3cFCoEFIPSnoopingFCFEntry 1 } h3cFCoEFIPSnoopingFCFIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "This index uniquely identifies an Ethernet interface that connects to the FCF." ::= { h3cFCoEFIPSnoopingFCFEntry 2 } h3cFCoEFIPSnoopingFCFMAC OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "The MAC address of the Ethernet interface on the FCF directly connected to the local device." ::= { h3cFCoEFIPSnoopingFCFEntry 3 } h3cFCoEFIPSnoopingFCFSwitchName OBJECT-TYPE SYNTAX H3cFcNameId MAX-ACCESS read-only STATUS current DESCRIPTION "The switch name of the FCF." ::= { h3cFCoEFIPSnoopingFCFEntry 4 } h3cFCoEFIPSnoopingFCFFabricName OBJECT-TYPE SYNTAX H3cFcNameId MAX-ACCESS read-only STATUS current DESCRIPTION "The fabric name of the FCF." ::= { h3cFCoEFIPSnoopingFCFEntry 5 } h3cFCoEFIPSnoopingFCFENodeCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of ENodes that log in through this Ethernet port." ::= { h3cFCoEFIPSnoopingFCFEntry 6 } -- FIP Snooping ENode information h3cFCoEFIPSnoopingENodeTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cFCoEFIPSnoopingENodeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table contains the ENode information on the local device." ::= { h3cFCoEConfig 7 } h3cFCoEFIPSnoopingENodeEntry OBJECT-TYPE SYNTAX H3cFCoEFIPSnoopingENodeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains information about an ENode for a VLAN." INDEX { fcmInstanceIndex, h3cFCoEFIPSnoopingENodeVLANIndex, h3cFCoEFIPSnoopingENodeIfIndex, h3cFCoEFIPSnoopingENodeMAC } ::= { h3cFCoEFIPSnoopingENodeTable 1 } H3cFCoEFIPSnoopingENodeEntry ::= SEQUENCE { h3cFCoEFIPSnoopingENodeVLANIndex VlanIndex, h3cFCoEFIPSnoopingENodeIfIndex InterfaceIndex, h3cFCoEFIPSnoopingENodeMAC MacAddress, h3cFCoEFIPSnoopingENodeName H3cFcNameId } h3cFCoEFIPSnoopingENodeVLANIndex OBJECT-TYPE SYNTAX VlanIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the VLAN-ID whose FIP Snooping function gets ready on the ENode." ::= { h3cFCoEFIPSnoopingENodeEntry 1 } h3cFCoEFIPSnoopingENodeIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "This index uniquely identifies an Ethernet interface that connects to the ENode." ::= { h3cFCoEFIPSnoopingENodeEntry 2 } h3cFCoEFIPSnoopingENodeMAC OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "The MAC address of the ENode." ::= { h3cFCoEFIPSnoopingENodeEntry 3 } h3cFCoEFIPSnoopingENodeName OBJECT-TYPE SYNTAX H3cFcNameId MAX-ACCESS read-only STATUS current DESCRIPTION "The node name of the ENode." ::= { h3cFCoEFIPSnoopingENodeEntry 4 } -- FIP Snooping VN information h3cFCoEFIPSnoopingVNTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cFCoEFIPSnoopingVNEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table contains the virtual N_Port information on the local device." ::= { h3cFCoEConfig 8 } h3cFCoEFIPSnoopingVNEntry OBJECT-TYPE SYNTAX H3cFCoEFIPSnoopingVNEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains information about a virtual N_Port." INDEX { fcmInstanceIndex, h3cFCoEFIPSnoopingVNVLANIndex, h3cFCoEFIPSnoopingVNENodeIfIndex, h3cFCoEFIPSnoopingVNENodeMAC, h3cFCoEFIPSnoopingVNFCFMAC, h3cFCoEFIPSnoopingVNMAC } ::= { h3cFCoEFIPSnoopingVNTable 1 } H3cFCoEFIPSnoopingVNEntry ::= SEQUENCE { h3cFCoEFIPSnoopingVNVLANIndex VlanIndex, h3cFCoEFIPSnoopingVNENodeIfIndex InterfaceIndex, h3cFCoEFIPSnoopingVNENodeMAC MacAddress, h3cFCoEFIPSnoopingVNFCFMAC MacAddress, h3cFCoEFIPSnoopingVNMAC MacAddress, h3cFCoEFIPSnoopingVNName H3cFcNameId, h3cFCoEFIPSnoopingVNFCFIfIndex InterfaceIndex } h3cFCoEFIPSnoopingVNVLANIndex OBJECT-TYPE SYNTAX VlanIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object identifies the VLAN-ID through which a virtual N_Port logs in to the FCF." ::= { h3cFCoEFIPSnoopingVNEntry 1 } h3cFCoEFIPSnoopingVNENodeIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "This index uniquely identifies an Ethernet interface that connects to the ENode." ::= { h3cFCoEFIPSnoopingVNEntry 2 } h3cFCoEFIPSnoopingVNENodeMAC OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "The MAC address of the ENode." ::= { h3cFCoEFIPSnoopingVNEntry 3 } h3cFCoEFIPSnoopingVNFCFMAC OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "The MAC address of the FCF." ::= { h3cFCoEFIPSnoopingVNEntry 4 } h3cFCoEFIPSnoopingVNMAC OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "The MAC address of the virtual N_Port." ::= { h3cFCoEFIPSnoopingVNEntry 5 } h3cFCoEFIPSnoopingVNName OBJECT-TYPE SYNTAX H3cFcNameId MAX-ACCESS read-only STATUS current DESCRIPTION "The port name of the virtual N_Port." ::= { h3cFCoEFIPSnoopingVNEntry 6 } h3cFCoEFIPSnoopingVNFCFIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This index uniquely identifies an Ethernet interface that connects to the FCF." ::= { h3cFCoEFIPSnoopingVNEntry 7 } -- FIP Snooping Config type of Ethernet h3cFCoEFIPSnoopingIfCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cFCoEFIPSnoopingIfCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table is used to configure FIP Snooping working mode of the Ethernet interface on the localdevice." ::= { h3cFCoEConfig 9 } h3cFCoEFIPSnoopingIfCfgEntry OBJECT-TYPE SYNTAX H3cFCoEFIPSnoopingIfCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains information about FIP Snooping working mode of the Ethernet interface." INDEX { fcmInstanceIndex, h3cFCoEFIPSnoopingIfCfgIfIndex } ::= { h3cFCoEFIPSnoopingIfCfgTable 1 } H3cFCoEFIPSnoopingIfCfgEntry ::= SEQUENCE { h3cFCoEFIPSnoopingIfCfgIfIndex InterfaceIndex, h3cFCoEFIPSnoopingIfCfgPortType INTEGER } h3cFCoEFIPSnoopingIfCfgIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "This index uniquely identifies an Ethernet interface." ::= { h3cFCoEFIPSnoopingIfCfgEntry 1 } h3cFCoEFIPSnoopingIfCfgPortType OBJECT-TYPE SYNTAX INTEGER { fcf(1), enode(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The FIP Snooping working mode of an Ethernet interface on the local device. The FCF mode means that the Ethernet interface must connect to an FCF. The ENode mode means that the Ethernet interface must connect to an ENode." ::= { h3cFCoEFIPSnoopingIfCfgEntry 2 } END