GUDEADS-ESB7213-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Unsigned32 FROM SNMPv2-SMI OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF; gudeads MODULE-IDENTITY LAST-UPDATED "201904041600Z" -- Apr 4, 2019, 4:00:00 PM ORGANIZATION "GUDE Systems GmbH" CONTACT-INFO "Von-der-Wettern-Str. 23 51149 Cologne Germany https://www.gude.info" DESCRIPTION "Expert Power Control 7213 MIB" REVISION "201904041600Z" -- Apr 4, 2019, 4:00:00 PM DESCRIPTION "" -- 1.3.6.1.4.1.28507 ::= { enterprises 28507 } epc7213NTPClient OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.66.1.5.15 ::= { esb7213IntSensors 15 } epc7213NTPUnixTime OBJECT-TYPE SYNTAX Unsigned32 UNITS "s" MAX-ACCESS read-only STATUS current DESCRIPTION "show received NTP time as unixtime (secs since 1 January 1970)" -- 1.3.6.1.4.1.28507.66.1.5.15.2 ::= { epc7213NTPClient 2 } epc7213NTPLastValidTimestamp OBJECT-TYPE SYNTAX Unsigned32 UNITS "s" MAX-ACCESS read-only STATUS current DESCRIPTION "show seconds since last valid NTP timestamp received" -- 1.3.6.1.4.1.28507.66.1.5.15.3 ::= { epc7213NTPClient 3 } epc7213NTPTimeValid OBJECT-TYPE SYNTAX INTEGER { notime(0), valid(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Show if valid Time is received" -- 1.3.6.1.4.1.28507.66.1.5.15.1 ::= { epc7213NTPClient 1 } esb7213ExtSensorName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "A textual string containing name of a external Sensor" -- 1.3.6.1.4.1.28507.66.1.6.1.1.32 ::= { esb7213SensorEntry 32 } esb7213AirPressure OBJECT-TYPE SYNTAX Integer32 UNITS "1 hPA (hectopascal) ~ 1 milibar" MAX-ACCESS read-only STATUS current DESCRIPTION "actual air pressure" -- 1.3.6.1.4.1.28507.66.1.6.1.1.5 ::= { esb7213SensorEntry 5 } esb7213DewPoint OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 degree Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "dew point for actual temperature and humidity" -- 1.3.6.1.4.1.28507.66.1.6.1.1.6 ::= { esb7213SensorEntry 6 } esb7213DewPointDiff OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 degree Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "difference between dew point and actual temperature (Temp - DewPoint)" -- 1.3.6.1.4.1.28507.66.1.6.1.1.7 ::= { esb7213SensorEntry 7 } esb7213POE OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "0 = no POE, 1 = POE available" MAX-ACCESS read-only STATUS current DESCRIPTION "signals POE availability" -- 1.3.6.1.4.1.28507.66.1.5.10 ::= { esb7213IntSensors 10 } esb7213POEEvt NOTIFICATION-TYPE OBJECTS { esb7213POE} STATUS current DESCRIPTION "Power over Ethernet changed" -- 1.3.6.1.4.1.28507.66.3.6 ::= { events 6 } gadsESB7213 OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.66 ::= { gudeads 66 } -- Notification Types -- events OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.66.3 ::= { gadsESB7213 3 } -- Scalars and Tables -- esb7213Objects OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.66.1 ::= { gadsESB7213 1 } esb7213CommonConfig OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.66.1.1 ::= { esb7213Objects 1 } esb7213SNMPaccess OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.66.1.1.1 ::= { esb7213CommonConfig 1 } esb7213TrapCtrl OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3" -- 1.3.6.1.4.1.28507.66.1.1.1.1 ::= { esb7213SNMPaccess 1 } esb7213TrapIPTable OBJECT-TYPE SYNTAX SEQUENCE OF Esb7213TrapIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "list of all Trap receiver" -- 1.3.6.1.4.1.28507.66.1.1.1.2 ::= { esb7213SNMPaccess 2 } esb7213TrapIPEntry OBJECT-TYPE SYNTAX Esb7213TrapIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "an entry containing management informations regarding the list of trap receivers" INDEX { esb7213TrapIPIndex } -- 1.3.6.1.4.1.28507.66.1.1.1.2.1 ::= { esb7213TrapIPTable 1 } Esb7213TrapIPEntry ::= SEQUENCE { esb7213TrapIPIndex Integer32, esb7213TrapAddr OCTET STRING } esb7213TrapIPIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each receiver slot." -- 1.3.6.1.4.1.28507.66.1.1.1.2.1.1 ::= { esb7213TrapIPEntry 1 } esb7213TrapAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..99)) MAX-ACCESS read-write STATUS current DESCRIPTION "DNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot." -- 1.3.6.1.4.1.28507.66.1.1.1.2.1.2 ::= { esb7213TrapIPEntry 2 } esb7213DeviceConfig OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.66.1.2 ::= { esb7213Objects 2 } esb7213IntActors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.66.1.3 ::= { esb7213Objects 3 } esb7213ExtActors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.66.1.4 ::= { esb7213Objects 4 } esb7213IntSensors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.66.1.5 ::= { esb7213Objects 5 } esb7213ExtSensors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.66.1.6 ::= { esb7213Objects 6 } esb7213SensorTable OBJECT-TYPE SYNTAX SEQUENCE OF Esb7213SensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.66.1.6.1 ::= { esb7213ExtSensors 1 } esb7213SensorEntry OBJECT-TYPE SYNTAX Esb7213SensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { esb7213SensorIndex } -- 1.3.6.1.4.1.28507.66.1.6.1.1 ::= { esb7213SensorTable 1 } Esb7213SensorEntry ::= SEQUENCE { esb7213SensorIndex Integer32, esb7213TempSensor Integer32, esb7213HygroSensor Integer32, esb7213InputSensor INTEGER, esb7213AirPressure Integer32, esb7213DewPoint Integer32, esb7213DewPointDiff Integer32, esb7213ExtSensorName OCTET STRING } esb7213SensorIndex OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.66.1.6.1.1.1 ::= { esb7213SensorEntry 1 } esb7213TempSensor OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 degree Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "actual temperature" -- 1.3.6.1.4.1.28507.66.1.6.1.1.2 ::= { esb7213SensorEntry 2 } esb7213HygroSensor OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 percent humidity" MAX-ACCESS read-only STATUS current DESCRIPTION "actual humidity" -- 1.3.6.1.4.1.28507.66.1.6.1.1.3 ::= { esb7213SensorEntry 3 } esb7213InputSensor OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "logical state of input sensor" -- 1.3.6.1.4.1.28507.66.1.6.1.1.4 ::= { esb7213SensorEntry 4 } -- Conformance -- esb7213Conf OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.66.2 ::= { gadsESB7213 2 } -- Groups -- esb7213Groups OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.66.2.1 ::= { esb7213Conf 1 } -- Compliance -- esb7213Compls OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.66.2.2 ::= { esb7213Conf 2 } esb7213BasicGroup OBJECT-GROUP OBJECTS { esb7213TrapCtrl, esb7213TrapIPIndex, esb7213TrapAddr, esb7213POE, esb7213SensorIndex, esb7213TempSensor, esb7213HygroSensor, esb7213InputSensor, esb7213AirPressure, esb7213DewPoint, esb7213DewPointDiff, esb7213ExtSensorName, epc7213NTPTimeValid, epc7213NTPUnixTime, epc7213NTPLastValidTimestamp } STATUS current DESCRIPTION "Basic objects." -- 1.3.6.1.4.1.28507.66.2.1.1 ::= { esb7213Groups 1 } esb7213NotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { esb7213TempEvtSen, esb7213HygroEvtSen, esb7213InputEvtSen, esb7213AirPressureEvtSen, esb7213DewPtDiffEvtSen, esb7213POEEvt } STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.66.2.1.2 ::= { esb7213Groups 2 } esb7213HygroEvtSen NOTIFICATION-TYPE OBJECTS { esb7213SensorIndex, esb7213HygroSensor} STATUS current DESCRIPTION "hygro limits exceeded" -- 1.3.6.1.4.1.28507.66.3.2 ::= { events 2 } esb7213InputEvtSen NOTIFICATION-TYPE OBJECTS { esb7213SensorIndex, esb7213InputSensor} STATUS current DESCRIPTION "change of logical input sensor state" -- 1.3.6.1.4.1.28507.66.3.3 ::= { events 3 } esb7213AirPressureEvtSen NOTIFICATION-TYPE OBJECTS { esb7213SensorIndex, esb7213AirPressure} STATUS current DESCRIPTION "Air Pressure limits exceeded " -- 1.3.6.1.4.1.28507.66.3.4 ::= { events 4 } esb7213DewPtDiffEvtSen NOTIFICATION-TYPE OBJECTS { esb7213SensorIndex, esb7213DewPointDiff} STATUS current DESCRIPTION "Dew Point Difference limits exceeded" -- 1.3.6.1.4.1.28507.66.3.5 ::= { events 5 } esb7213TempEvtSen NOTIFICATION-TYPE OBJECTS { esb7213SensorIndex, esb7213TempSensor} STATUS current DESCRIPTION "temperature limits exceeded" -- 1.3.6.1.4.1.28507.66.3.1 ::= { events 1 } END