GUDEADS-EPC8221-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Gauge32, Integer32, Unsigned32 FROM SNMPv2-SMI OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF; gudeads MODULE-IDENTITY LAST-UPDATED "200703051356Z" -- Mar 5, 2007 1:56:00 PM ORGANIZATION "Gude Analog- und Digitalsysteme GmbH" CONTACT-INFO "http://www.gudeads.com/" DESCRIPTION "" REVISION "200703051356Z" -- Mar 5, 2007 1:56:00 PM DESCRIPTION "$Id:$" -- 1.3.6.1.4.1.28507 ::= { enterprises 28507 } -- Notification Types -- events OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.56.3 ::= { gadsEPC8221 3 } epc8221SwitchEvtPort NOTIFICATION-TYPE OBJECTS { epc8221PortIndex, epc8221PortName, epc8221PortState, epc8221PortSwitchCount} STATUS current DESCRIPTION "Event is triggered when a port is switched" -- 1.3.6.1.4.1.28507.56.3.1 ::= { events 1 } epc8221TempEvtSen NOTIFICATION-TYPE OBJECTS { epc8221SensorIndex, epc8221TempSensor} STATUS current DESCRIPTION "temperature limits exceeded" -- 1.3.6.1.4.1.28507.56.3.2 ::= { events 2 } epc8221InputEvtSen NOTIFICATION-TYPE OBJECTS { epc8221SensorIndex, epc8221InputSensor} STATUS current DESCRIPTION "change of logical input sensor state" -- 1.3.6.1.4.1.28507.56.3.4 ::= { events 4 } epc8221AirPressureEvtSen NOTIFICATION-TYPE OBJECTS { epc8221SensorIndex, epc8221AirPressure} STATUS current DESCRIPTION "Air Pressure limits exceeded " -- 1.3.6.1.4.1.28507.56.3.5 ::= { events 5 } epc8221DewPtDiffEvtSen NOTIFICATION-TYPE OBJECTS { epc8221SensorIndex, epc8221DewPointDiff} STATUS current DESCRIPTION "Dew Point Difference limits exceeded" -- 1.3.6.1.4.1.28507.56.3.6 ::= { events 6 } epc8221OVPEvt NOTIFICATION-TYPE OBJECTS { epc8221OVPIndex, epc8221OVPStatus} STATUS current DESCRIPTION "Event is triggered when the OVP status changes" -- 1.3.6.1.4.1.28507.56.3.7 ::= { events 7 } epc8221LineAmperageEvt NOTIFICATION-TYPE OBJECTS { epc8221PowerIndex, epc8221PowerActive, epc8221Current, epc8221Voltage, epc8221Frequency, epc8221PowerApparent, epc8221PowerReactive} STATUS current DESCRIPTION "Event is triggered when a measured current is crossing the entered limits" -- 1.3.6.1.4.1.28507.56.3.8 ::= { events 8 } epc8221Voltage OBJECT-TYPE SYNTAX Gauge32 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "Actual Voltage on Power Channel" -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.6 ::= { epc8221PowerEntry 6 } epc8221Frequency OBJECT-TYPE SYNTAX Gauge32 UNITS "0.01 hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Frequency of Power Channel" -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.7 ::= { epc8221PowerEntry 7 } epc8221AbsEnergyReactive OBJECT-TYPE SYNTAX Gauge32 UNITS "VARh" MAX-ACCESS read-only STATUS current DESCRIPTION "Absolute Reactive Energy counter." -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.12 ::= { epc8221PowerEntry 12 } epc8221AbsEnergyActiveResettable OBJECT-TYPE SYNTAX Gauge32 UNITS "Wh" MAX-ACCESS read-write STATUS current DESCRIPTION "Resettable Absolute Active Energy counter. Writing '0' resets all resettable counter." -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.13 ::= { epc8221PowerEntry 13 } epc8221AbsEnergyReactiveResettable OBJECT-TYPE SYNTAX Gauge32 UNITS "VARh" MAX-ACCESS read-only STATUS current DESCRIPTION "Resettable Absolute Reactive Energy counter." -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.14 ::= { epc8221PowerEntry 14 } epc8221ResetTime OBJECT-TYPE SYNTAX Gauge32 UNITS "s" MAX-ACCESS read-only STATUS current DESCRIPTION "Time in seconds since last Energy Counter reset." -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.15 ::= { epc8221PowerEntry 15 } epc8221ForwEnergyActive OBJECT-TYPE SYNTAX Gauge32 UNITS "Wh" MAX-ACCESS read-only STATUS current DESCRIPTION "Forward Active Energy counter." -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.16 ::= { epc8221PowerEntry 16 } epc8221ForwEnergyReactive OBJECT-TYPE SYNTAX Gauge32 UNITS "VARh" MAX-ACCESS read-only STATUS current DESCRIPTION "Forward Reactive Energy counter." -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.17 ::= { epc8221PowerEntry 17 } epc8221ForwEnergyActiveResettable OBJECT-TYPE SYNTAX Gauge32 UNITS "Wh" MAX-ACCESS read-only STATUS current DESCRIPTION "Resettable Forward Active Energy counter." -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.18 ::= { epc8221PowerEntry 18 } epc8221ForwEnergyReactiveResettable OBJECT-TYPE SYNTAX Gauge32 UNITS "VARh" MAX-ACCESS read-only STATUS current DESCRIPTION "Resettable Forward Reactive Energy counter." -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.19 ::= { epc8221PowerEntry 19 } epc8221RevEnergyActive OBJECT-TYPE SYNTAX Gauge32 UNITS "Wh" MAX-ACCESS read-only STATUS current DESCRIPTION "Reverse Active Energy counter." -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.20 ::= { epc8221PowerEntry 20 } epc8221RevEnergyReactive OBJECT-TYPE SYNTAX Gauge32 UNITS "VARh" MAX-ACCESS read-only STATUS current DESCRIPTION "Reverse Reactive Energy counter." -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.21 ::= { epc8221PowerEntry 21 } epc8221RevEnergyActiveResettable OBJECT-TYPE SYNTAX Gauge32 UNITS "Wh" MAX-ACCESS read-only STATUS current DESCRIPTION "Resettable Reverse Active Energy counter." -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.22 ::= { epc8221PowerEntry 22 } epc8221RevEnergyReactiveResettable OBJECT-TYPE SYNTAX Gauge32 UNITS "VARh" MAX-ACCESS read-only STATUS current DESCRIPTION "Resettable Reverse Reactive Energy counter." -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.23 ::= { epc8221PowerEntry 23 } epc8221AbsEnergyActive OBJECT-TYPE SYNTAX Gauge32 UNITS "Wh" MAX-ACCESS read-only STATUS current DESCRIPTION "Absolute Active Energy counter." -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.3 ::= { epc8221PowerEntry 3 } gadsEPC8221 OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.56 ::= { gudeads 56 } -- Scalars and Tables -- epc8221Objects OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.56.1 ::= { gadsEPC8221 1 } epc8221CommonConfig OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.56.1.1 ::= { epc8221Objects 1 } epc8221SNMPaccess OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.56.1.1.1 ::= { epc8221CommonConfig 1 } epc8221TrapCtrl OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3" -- 1.3.6.1.4.1.28507.56.1.1.1.1 ::= { epc8221SNMPaccess 1 } epc8221TrapIPTable OBJECT-TYPE SYNTAX SEQUENCE OF Epc8221TrapIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "list of all Trap receiver" -- 1.3.6.1.4.1.28507.56.1.1.1.2 ::= { epc8221SNMPaccess 2 } epc8221TrapIPEntry OBJECT-TYPE SYNTAX Epc8221TrapIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "an entry containing management informations regarding the list of trap receivers" INDEX { epc8221TrapIPIndex } -- 1.3.6.1.4.1.28507.56.1.1.1.2.1 ::= { epc8221TrapIPTable 1 } Epc8221TrapIPEntry ::= SEQUENCE { epc8221TrapIPIndex Integer32, epc8221TrapAddr OCTET STRING } epc8221TrapIPIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each receiver slot." -- 1.3.6.1.4.1.28507.56.1.1.1.2.1.1 ::= { epc8221TrapIPEntry 1 } epc8221TrapAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..99)) MAX-ACCESS read-write STATUS current DESCRIPTION "DNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot." -- 1.3.6.1.4.1.28507.56.1.1.1.2.1.2 ::= { epc8221TrapIPEntry 2 } epc8221DeviceConfig OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.56.1.2 ::= { epc8221Objects 2 } epc8221IntActors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.56.1.3 ::= { epc8221Objects 3 } epc8221relayports OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.56.1.3.1 ::= { epc8221IntActors 1 } epc8221portNumber OBJECT-TYPE SYNTAX Integer32 (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Relay Ports" -- 1.3.6.1.4.1.28507.56.1.3.1.1 ::= { epc8221relayports 1 } -- the Interfaces table -- The Interfaces table contains information on the entity's -- interfaces. Each sub-layer below the internetwork-layer -- of a network interface is considered to be an interface. epc8221portTable OBJECT-TYPE SYNTAX SEQUENCE OF Epc8221portEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "list of all EPC Relay Ports" -- 1.3.6.1.4.1.28507.56.1.3.1.2 ::= { epc8221relayports 2 } epc8221portEntry OBJECT-TYPE SYNTAX Epc8221portEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular relay port." INDEX { epc8221PortIndex } -- 1.3.6.1.4.1.28507.56.1.3.1.2.1 ::= { epc8221portTable 1 } Epc8221portEntry ::= SEQUENCE { epc8221PortIndex Integer32, epc8221PortName OCTET STRING, epc8221PortState INTEGER, epc8221PortSwitchCount Integer32, epc8221PortStartupMode INTEGER, epc8221PortStartupDelay Integer32, epc8221PortRepowerTime Integer32 } epc8221PortIndex OBJECT-TYPE SYNTAX Integer32 (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each Relay Port." -- 1.3.6.1.4.1.28507.56.1.3.1.2.1.1 ::= { epc8221portEntry 1 } epc8221PortName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-write STATUS current DESCRIPTION "A textual string containing name of a Relay Port." -- 1.3.6.1.4.1.28507.56.1.3.1.2.1.2 ::= { epc8221portEntry 2 } epc8221PortState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "current state of a Relay Port" -- 1.3.6.1.4.1.28507.56.1.3.1.2.1.3 ::= { epc8221portEntry 3 } epc8221PortSwitchCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of switch actions ocurred on a Relay Port. Does not count switch commands which will not switch the ralay state, so just real relay switches are displayed here." -- 1.3.6.1.4.1.28507.56.1.3.1.2.1.4 ::= { epc8221portEntry 4 } epc8221PortStartupMode OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), laststate(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "set Mode of startup sequence (off, on , remember last state)" DEFVAL { off } -- 1.3.6.1.4.1.28507.56.1.3.1.2.1.5 ::= { epc8221portEntry 5 } epc8221PortStartupDelay OBJECT-TYPE SYNTAX Integer32 UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Delay in sec for startup action" DEFVAL { 0 } -- 1.3.6.1.4.1.28507.56.1.3.1.2.1.6 ::= { epc8221portEntry 6 } epc8221PortRepowerTime OBJECT-TYPE SYNTAX Integer32 (0..65535) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Delay in sec for repower port after switching off" DEFVAL { 0 } -- 1.3.6.1.4.1.28507.56.1.3.1.2.1.7 ::= { epc8221portEntry 7 } epc8221Buzzer OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "0 = Off, 1 = On" MAX-ACCESS read-write STATUS current DESCRIPTION "turn Buzzer on and off" -- 1.3.6.1.4.1.28507.56.1.3.10 ::= { epc8221IntActors 10 } epc8221ExtActors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.56.1.4 ::= { epc8221Objects 4 } epc8221IntSensors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.56.1.5 ::= { epc8221Objects 5 } epc8221PowerChan OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.56.1.5.1 ::= { epc8221IntSensors 1 } epc8221ActivePowerChan OBJECT-TYPE SYNTAX Unsigned32 (1) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of suppported Power Channels." -- 1.3.6.1.4.1.28507.56.1.5.1.1 ::= { epc8221PowerChan 1 } epc8221PowerTable OBJECT-TYPE SYNTAX SEQUENCE OF Epc8221PowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "All available Channel Interfaces." -- 1.3.6.1.4.1.28507.56.1.5.1.2 ::= { epc8221PowerChan 2 } epc8221PowerEntry OBJECT-TYPE SYNTAX Epc8221PowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular Power Channel." INDEX { epc8221PowerIndex } -- 1.3.6.1.4.1.28507.56.1.5.1.2.1 ::= { epc8221PowerTable 1 } Epc8221PowerEntry ::= SEQUENCE { epc8221PowerIndex Integer32, epc8221ChanStatus Integer32, epc8221AbsEnergyActive Gauge32, epc8221PowerActive Integer32, epc8221Current Gauge32, epc8221Voltage Gauge32, epc8221Frequency Gauge32, epc8221PowerFactor Integer32, epc8221Pangle Integer32, epc8221PowerApparent Integer32, epc8221PowerReactive Integer32, epc8221AbsEnergyReactive Gauge32, epc8221AbsEnergyActiveResettable Gauge32, epc8221AbsEnergyReactiveResettable Gauge32, epc8221ResetTime Gauge32, epc8221ForwEnergyActive Gauge32, epc8221ForwEnergyReactive Gauge32, epc8221ForwEnergyActiveResettable Gauge32, epc8221ForwEnergyReactiveResettable Gauge32, epc8221RevEnergyActive Gauge32, epc8221RevEnergyReactive Gauge32, epc8221RevEnergyActiveResettable Gauge32, epc8221RevEnergyReactiveResettable Gauge32 } epc8221PowerIndex OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of Power Channel entries" -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.1 ::= { epc8221PowerEntry 1 } epc8221ChanStatus OBJECT-TYPE SYNTAX Integer32 (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "0 = data not active, 1 = data valid" -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.2 ::= { epc8221PowerEntry 2 } epc8221PowerActive OBJECT-TYPE SYNTAX Integer32 UNITS "W" MAX-ACCESS read-only STATUS current DESCRIPTION "Active Power" -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.4 ::= { epc8221PowerEntry 4 } epc8221Current OBJECT-TYPE SYNTAX Gauge32 UNITS "mA" MAX-ACCESS read-only STATUS current DESCRIPTION "Actual Curent on Power Channel." -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.5 ::= { epc8221PowerEntry 5 } epc8221PowerFactor OBJECT-TYPE SYNTAX Integer32 UNITS "0.001" MAX-ACCESS read-only STATUS current DESCRIPTION "Power Factor of Channel between -1.0 and 1.00" -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.8 ::= { epc8221PowerEntry 8 } epc8221Pangle OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 degree" MAX-ACCESS read-only STATUS current DESCRIPTION "Phase Angle between Voltage and L Line Current between -180.0 and 180.0" -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.9 ::= { epc8221PowerEntry 9 } epc8221PowerApparent OBJECT-TYPE SYNTAX Integer32 UNITS "VA" MAX-ACCESS read-only STATUS current DESCRIPTION "L Line Mean Apparent Power" -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.10 ::= { epc8221PowerEntry 10 } epc8221PowerReactive OBJECT-TYPE SYNTAX Integer32 UNITS "VAR" MAX-ACCESS read-only STATUS current DESCRIPTION "L Line Mean Reactive Power" -- 1.3.6.1.4.1.28507.56.1.5.1.2.1.11 ::= { epc8221PowerEntry 11 } epc8221OVPTable OBJECT-TYPE SYNTAX SEQUENCE OF Epc8221OVPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Overvoltage Protection Table This table may not be present on devices without OVP feature" -- 1.3.6.1.4.1.28507.56.1.5.2 ::= { epc8221IntSensors 2 } epc8221OVPEntry OBJECT-TYPE SYNTAX Epc8221OVPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { epc8221OVPIndex } -- 1.3.6.1.4.1.28507.56.1.5.2.1 ::= { epc8221OVPTable 1 } Epc8221OVPEntry ::= SEQUENCE { epc8221OVPIndex Integer32, epc8221OVPStatus INTEGER } epc8221OVPIndex OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.56.1.5.2.1.1 ::= { epc8221OVPEntry 1 } epc8221ExtSensors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.56.1.6 ::= { epc8221Objects 6 } epc8221SensorTable OBJECT-TYPE SYNTAX SEQUENCE OF Epc8221SensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.56.1.6.1 ::= { epc8221ExtSensors 1 } epc8221SensorEntry OBJECT-TYPE SYNTAX Epc8221SensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { epc8221SensorIndex } -- 1.3.6.1.4.1.28507.56.1.6.1.1 ::= { epc8221SensorTable 1 } Epc8221SensorEntry ::= SEQUENCE { epc8221SensorIndex Integer32, epc8221TempSensor Integer32, epc8221HygroSensor Integer32, epc8221InputSensor INTEGER, epc8221AirPressure Integer32, epc8221DewPoint Integer32, epc8221DewPointDiff Integer32 } epc8221SensorIndex OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.56.1.6.1.1.1 ::= { epc8221SensorEntry 1 } epc8221TempSensor OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 degree Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "actual temperature" -- 1.3.6.1.4.1.28507.56.1.6.1.1.2 ::= { epc8221SensorEntry 2 } epc8221AirPressure OBJECT-TYPE SYNTAX Integer32 UNITS "1 hPA (hectopascal) ~ 1 milibar" MAX-ACCESS read-only STATUS current DESCRIPTION "actual air pressure" -- 1.3.6.1.4.1.28507.56.1.6.1.1.5 ::= { epc8221SensorEntry 5 } epc8221DewPoint OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 degree Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "dew point for actual temperature and humidity" -- 1.3.6.1.4.1.28507.56.1.6.1.1.6 ::= { epc8221SensorEntry 6 } epc8221DewPointDiff OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 degree Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "difference between dew point and actual temperature (Temp - DewPoint)" -- 1.3.6.1.4.1.28507.56.1.6.1.1.7 ::= { epc8221SensorEntry 7 } epc8221HygroSensor OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 percent humidity" MAX-ACCESS read-only STATUS current DESCRIPTION "actual humidity" -- 1.3.6.1.4.1.28507.56.1.6.1.1.3 ::= { epc8221SensorEntry 3 } epc8221InputSensor OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "logical state of input sensor" -- 1.3.6.1.4.1.28507.56.1.6.1.1.4 ::= { epc8221SensorEntry 4 } -- Conformance -- epc8221Conf OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.56.2 ::= { gadsEPC8221 2 } -- Groups -- epc8221Groups OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.56.2.1 ::= { epc8221Conf 1 } -- Compliance -- epc8221Compls OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.56.2.2 ::= { epc8221Conf 2 } epc8221BasicGroup OBJECT-GROUP OBJECTS { epc8221TrapCtrl, epc8221TrapIPIndex, epc8221TrapAddr, epc8221portNumber, epc8221PortIndex, epc8221PortName, epc8221PortState, epc8221PortSwitchCount, epc8221PortStartupMode, epc8221PortStartupDelay, epc8221PortRepowerTime, epc8221Buzzer, epc8221ActivePowerChan, epc8221PowerIndex, epc8221ChanStatus, epc8221AbsEnergyActive, epc8221PowerActive, epc8221Current, epc8221Voltage, epc8221Frequency, epc8221PowerFactor, epc8221Pangle, epc8221PowerApparent, epc8221PowerReactive, epc8221AbsEnergyReactive, epc8221AbsEnergyActiveResettable, epc8221AbsEnergyReactiveResettable, epc8221ResetTime, epc8221ForwEnergyActive, epc8221ForwEnergyReactive, epc8221ForwEnergyActiveResettable, epc8221ForwEnergyReactiveResettable, epc8221RevEnergyActive, epc8221RevEnergyReactive, epc8221RevEnergyActiveResettable, epc8221RevEnergyReactiveResettable, epc8221OVPIndex, epc8221OVPStatus, epc8221SensorIndex, epc8221TempSensor, epc8221HygroSensor, epc8221InputSensor, epc8221AirPressure, epc8221DewPoint, epc8221DewPointDiff } STATUS current DESCRIPTION "Basic objects." -- 1.3.6.1.4.1.28507.56.2.1.1 ::= { epc8221Groups 1 } epc8221NotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { epc8221SwitchEvtPort, epc8221TempEvtSen, epc8221HygroEvtSen, epc8221InputEvtSen, epc8221AirPressureEvtSen, epc8221DewPtDiffEvtSen, epc8221OVPEvt, epc8221LineAmperageEvt } STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.56.2.1.2 ::= { epc8221Groups 2 } epc8221HygroEvtSen NOTIFICATION-TYPE OBJECTS { epc8221SensorIndex, epc8221HygroSensor} STATUS current DESCRIPTION "hygro limits exceeded" -- 1.3.6.1.4.1.28507.56.3.3 ::= { events 3 } epc8221OVPStatus OBJECT-TYPE SYNTAX INTEGER { unknown(2), ok(1), failure(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "shows the status of the built-in Overvoltage Protection" -- 1.3.6.1.4.1.28507.56.1.5.2.1.2 ::= { epc8221OVPEntry 2 } END