GUDEADS-EPC1105-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Unsigned32 FROM SNMPv2-SMI OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF; gudeads MODULE-IDENTITY LAST-UPDATED "200703051356Z" -- Mar 5, 2007 1:56:00 PM ORGANIZATION "Gude Analog- und Digitalsysteme GmbH" CONTACT-INFO "http://www.gudeads.com/" DESCRIPTION "" REVISION "200703051356Z" -- Mar 5, 2007 1:56:00 PM DESCRIPTION "$Id:$" -- 1.3.6.1.4.1.28507 ::= { enterprises 28507 } gadsEPC1105 OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.69 ::= { gudeads 69 } -- Scalars and Tables -- epc1105Objects OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.69.1 ::= { gadsEPC1105 1 } epc1105CommonConfig OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.69.1.1 ::= { epc1105Objects 1 } epc1105SNMPaccess OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.69.1.1.1 ::= { epc1105CommonConfig 1 } epc1105TrapCtrl OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3" -- 1.3.6.1.4.1.28507.69.1.1.1.1 ::= { epc1105SNMPaccess 1 } epc1105TrapIPTable OBJECT-TYPE SYNTAX SEQUENCE OF Epc8TrapIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "list of all Trap receiver" -- 1.3.6.1.4.1.28507.69.1.1.1.2 ::= { epc1105SNMPaccess 2 } epc1105TrapIPEntry OBJECT-TYPE SYNTAX Epc8TrapIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "an entry containing management informations regarding the list of trap receivers" INDEX { epc1105TrapIPIndex } -- 1.3.6.1.4.1.28507.69.1.1.1.2.1 ::= { epc1105TrapIPTable 1 } Epc8TrapIPEntry ::= SEQUENCE { epc1105TrapIPIndex Integer32, epc1105TrapAddr OCTET STRING } epc1105TrapIPIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each receiver slot." -- 1.3.6.1.4.1.28507.69.1.1.1.2.1.1 ::= { epc1105TrapIPEntry 1 } epc1105TrapAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..99)) MAX-ACCESS read-write STATUS current DESCRIPTION "DNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot." -- 1.3.6.1.4.1.28507.69.1.1.1.2.1.2 ::= { epc1105TrapIPEntry 2 } epc1105DeviceConfig OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.69.1.2 ::= { epc1105Objects 2 } epc1105IntActors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.69.1.3 ::= { epc1105Objects 3 } epc1105relayports OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.69.1.3.1 ::= { epc1105IntActors 1 } epc1105portNumber OBJECT-TYPE SYNTAX Integer32 (1) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Relay Ports" -- 1.3.6.1.4.1.28507.69.1.3.1.1 ::= { epc1105relayports 1 } -- the Interfaces table -- The Interfaces table contains information on the entity's -- interfaces. Each sub-layer below the internetwork-layer -- of a network interface is considered to be an interface. epc1105portTable OBJECT-TYPE SYNTAX SEQUENCE OF Epc1105portEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "list of all EPC Relay Ports" -- 1.3.6.1.4.1.28507.69.1.3.1.2 ::= { epc1105relayports 2 } epc1105portEntry OBJECT-TYPE SYNTAX Epc1105portEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular relay port." INDEX { epc1105PortIndex } -- 1.3.6.1.4.1.28507.69.1.3.1.2.1 ::= { epc1105portTable 1 } Epc1105portEntry ::= SEQUENCE { epc1105PortIndex Integer32, epc1105PortName OCTET STRING, epc1105PortState INTEGER, epc1105PortSwitchCount Integer32, epc1105PortStartupMode INTEGER, epc1105PortStartupDelay Integer32, epc1105PortRepowerTime Integer32 } epc1105PortIndex OBJECT-TYPE SYNTAX Integer32 (1) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each Relay Port." -- 1.3.6.1.4.1.28507.69.1.3.1.2.1.1 ::= { epc1105portEntry 1 } epc1105PortName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-write STATUS current DESCRIPTION "A textual string containing name of a Relay Port." -- 1.3.6.1.4.1.28507.69.1.3.1.2.1.2 ::= { epc1105portEntry 2 } epc1105PortState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "current state a Relay Port" -- 1.3.6.1.4.1.28507.69.1.3.1.2.1.3 ::= { epc1105portEntry 3 } epc1105PortSwitchCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of switch actions ocurred on a Relay Port. Does not count switch commands which will not switch the ralay state, so just real relay switches are displayed here." -- 1.3.6.1.4.1.28507.69.1.3.1.2.1.4 ::= { epc1105portEntry 4 } epc1105PortStartupMode OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), laststate(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "set Mode of startup sequence (off, on , remember last state)" DEFVAL { off } -- 1.3.6.1.4.1.28507.69.1.3.1.2.1.5 ::= { epc1105portEntry 5 } epc1105PortStartupDelay OBJECT-TYPE SYNTAX Integer32 UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Delay in sec for startup action" DEFVAL { 0 } -- 1.3.6.1.4.1.28507.69.1.3.1.2.1.6 ::= { epc1105portEntry 6 } epc1105PortRepowerTime OBJECT-TYPE SYNTAX Integer32 (0..65535) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Delay in sec for repower port after switching off" DEFVAL { 0 } -- 1.3.6.1.4.1.28507.69.1.3.1.2.1.7 ::= { epc1105portEntry 7 } epc1105ExtActors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.69.1.4 ::= { epc1105Objects 4 } epc1105IntSensors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.69.1.5 ::= { epc1105Objects 5 } epc1105PowerChan OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.69.1.5.1 ::= { epc1105IntSensors 1 } epc1105ActivePowerChan OBJECT-TYPE SYNTAX Unsigned32 (1) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of suppported Power Channels." -- 1.3.6.1.4.1.28507.69.1.5.1.1 ::= { epc1105PowerChan 1 } epc1105PowerTable OBJECT-TYPE SYNTAX SEQUENCE OF Epc1105PowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "All available Channel Interfaces." -- 1.3.6.1.4.1.28507.69.1.5.1.2 ::= { epc1105PowerChan 2 } epc1105PowerEntry OBJECT-TYPE SYNTAX Epc1105PowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular Power Channel." INDEX { epc1105PowerIndex } -- 1.3.6.1.4.1.28507.69.1.5.1.2.1 ::= { epc1105PowerTable 1 } Epc1105PowerEntry ::= SEQUENCE { epc1105PowerIndex Integer32, epc1105ChanStatus Integer32, epc1105AbsEnergyActive Unsigned32, epc1105PowerActive Integer32, epc1105Current Unsigned32, epc1105Voltage Unsigned32, epc1105Frequency Unsigned32, epc1105PowerFactor Integer32, epc1105Pangle Integer32, epc1105PowerApparent Integer32, epc1105PowerReactive Integer32, epc1105AbsEnergyReactive Unsigned32, epc1105AbsEnergyActiveResettable Unsigned32, epc1105AbsEnergyReactiveResettable Unsigned32, epc1105ResetTime Unsigned32, epc1105ForwEnergyActive Unsigned32, epc1105ForwEnergyReactive Unsigned32, epc1105ForwEnergyActiveResettable Unsigned32, epc1105ForwEnergyReactiveResettable Unsigned32, epc1105RevEnergyActive Unsigned32, epc1105RevEnergyReactive Unsigned32, epc1105RevEnergyActiveResettable Unsigned32, epc1105RevEnergyReactiveResettable Unsigned32 } epc1105PowerIndex OBJECT-TYPE SYNTAX Integer32 (1) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of Power Channel entries" -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.1 ::= { epc1105PowerEntry 1 } epc1105ChanStatus OBJECT-TYPE SYNTAX Integer32 (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "0 = data not active, 1 = data valid" -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.2 ::= { epc1105PowerEntry 2 } epc1105AbsEnergyActive OBJECT-TYPE SYNTAX Unsigned32 UNITS "Wh" MAX-ACCESS read-only STATUS current DESCRIPTION "Absolute Active Energy counter." -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.3 ::= { epc1105PowerEntry 3 } epc1105PowerActive OBJECT-TYPE SYNTAX Integer32 UNITS "W" MAX-ACCESS read-only STATUS current DESCRIPTION "Active Power" -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.4 ::= { epc1105PowerEntry 4 } epc1105Current OBJECT-TYPE SYNTAX Unsigned32 UNITS "mA" MAX-ACCESS read-only STATUS current DESCRIPTION "Actual Curent on Power Channel." -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.5 ::= { epc1105PowerEntry 5 } epc1105Voltage OBJECT-TYPE SYNTAX Unsigned32 UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "Actual Voltage on Power Channel" -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.6 ::= { epc1105PowerEntry 6 } epc1105Frequency OBJECT-TYPE SYNTAX Unsigned32 UNITS "0.01 hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Frequency of Power Channel" -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.7 ::= { epc1105PowerEntry 7 } epc1105PowerFactor OBJECT-TYPE SYNTAX Integer32 UNITS "0.001" MAX-ACCESS read-only STATUS current DESCRIPTION "Power Factor of Channel between -1.0 and 1.00" -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.8 ::= { epc1105PowerEntry 8 } epc1105Pangle OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 degree" MAX-ACCESS read-only STATUS current DESCRIPTION "Phase Angle between Voltage and L Line Current between -180.0 and 180.0" -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.9 ::= { epc1105PowerEntry 9 } epc1105PowerApparent OBJECT-TYPE SYNTAX Integer32 UNITS "VA" MAX-ACCESS read-only STATUS current DESCRIPTION "L Line Mean Apparent Power" -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.10 ::= { epc1105PowerEntry 10 } epc1105PowerReactive OBJECT-TYPE SYNTAX Integer32 UNITS "VAR" MAX-ACCESS read-only STATUS current DESCRIPTION "L Line Mean Reactive Power" -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.11 ::= { epc1105PowerEntry 11 } epc1105AbsEnergyReactive OBJECT-TYPE SYNTAX Unsigned32 UNITS "VARh" MAX-ACCESS read-only STATUS current DESCRIPTION "Absolute Reactive Energy counter." -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.12 ::= { epc1105PowerEntry 12 } epc1105AbsEnergyActiveResettable OBJECT-TYPE SYNTAX Unsigned32 UNITS "Wh" MAX-ACCESS read-write STATUS current DESCRIPTION "Resettable Absolute Active Energy counter. Writing '0' resets all resettable counter.r." -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.13 ::= { epc1105PowerEntry 13 } epc1105AbsEnergyReactiveResettable OBJECT-TYPE SYNTAX Unsigned32 UNITS "VARh" MAX-ACCESS read-only STATUS current DESCRIPTION "Resettable Absolute Reactive Energy counter." -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.14 ::= { epc1105PowerEntry 14 } epc1105ResetTime OBJECT-TYPE SYNTAX Unsigned32 UNITS "s" MAX-ACCESS read-only STATUS current DESCRIPTION "Time in seconds since last Energy Counter reset." -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.15 ::= { epc1105PowerEntry 15 } epc1105ForwEnergyActive OBJECT-TYPE SYNTAX Unsigned32 UNITS "Wh" MAX-ACCESS read-only STATUS current DESCRIPTION "Forward Active Energy counter." -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.16 ::= { epc1105PowerEntry 16 } epc1105ForwEnergyReactive OBJECT-TYPE SYNTAX Unsigned32 UNITS "VARh" MAX-ACCESS read-only STATUS current DESCRIPTION "Forward Reactive Energy counter." -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.17 ::= { epc1105PowerEntry 17 } epc1105ForwEnergyActiveResettable OBJECT-TYPE SYNTAX Unsigned32 UNITS "Wh" MAX-ACCESS read-only STATUS current DESCRIPTION "Resettable Forward Active Energy counter." -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.18 ::= { epc1105PowerEntry 18 } epc1105ForwEnergyReactiveResettable OBJECT-TYPE SYNTAX Unsigned32 UNITS "VARh" MAX-ACCESS read-only STATUS current DESCRIPTION "Resettable Forward Reactive Energy counter." -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.19 ::= { epc1105PowerEntry 19 } epc1105RevEnergyActive OBJECT-TYPE SYNTAX Unsigned32 UNITS "Wh" MAX-ACCESS read-only STATUS current DESCRIPTION "Reverse Active Energy counter." -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.20 ::= { epc1105PowerEntry 20 } epc1105RevEnergyReactive OBJECT-TYPE SYNTAX Unsigned32 UNITS "VARh" MAX-ACCESS read-only STATUS current DESCRIPTION "Reverse Reactive Energy counter." -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.21 ::= { epc1105PowerEntry 21 } epc1105RevEnergyActiveResettable OBJECT-TYPE SYNTAX Unsigned32 UNITS "Wh" MAX-ACCESS read-only STATUS current DESCRIPTION "Resettable Reverse Active Energy counter." -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.22 ::= { epc1105PowerEntry 22 } epc1105RevEnergyReactiveResettable OBJECT-TYPE SYNTAX Unsigned32 UNITS "VARh" MAX-ACCESS read-only STATUS current DESCRIPTION "Resettable Reverse Reactive Energy counter." -- 1.3.6.1.4.1.28507.69.1.5.1.2.1.23 ::= { epc1105PowerEntry 23 } epc1105ExtSensors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.69.1.6 ::= { epc1105Objects 6 } -- Conformance -- epc1105Conf OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.69.2 ::= { gadsEPC1105 2 } -- Groups -- epc1105Groups OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.69.2.1 ::= { epc1105Conf 1 } -- Compliance -- epc1105Compls OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.69.2.2 ::= { epc1105Conf 2 } epc1105BasicGroup OBJECT-GROUP OBJECTS { epc1105TrapCtrl, epc1105TrapIPIndex, epc1105TrapAddr, epc1105portNumber, epc1105PortIndex, epc1105PortName, epc1105PortState, epc1105PortSwitchCount, epc1105PortStartupMode, epc1105PortStartupDelay, epc1105PortRepowerTime, epc1105ActivePowerChan, epc1105PowerIndex, epc1105ChanStatus, epc1105AbsEnergyActive, epc1105PowerActive, epc1105Current, epc1105Voltage, epc1105Frequency, epc1105PowerFactor, epc1105Pangle, epc1105PowerApparent, epc1105PowerReactive, epc1105AbsEnergyReactive, epc1105AbsEnergyActiveResettable, epc1105AbsEnergyReactiveResettable, epc1105ResetTime, epc1105ForwEnergyActive, epc1105ForwEnergyReactive, epc1105ForwEnergyActiveResettable, epc1105ForwEnergyReactiveResettable, epc1105RevEnergyActive, epc1105RevEnergyReactive, epc1105RevEnergyActiveResettable, epc1105RevEnergyReactiveResettable, epc1105SensorIndex, epc1105TempSensor, epc1105HygroSensor, epc1105InputSensor, epc1105AirPressure, epc1105DewPoint, epc1105DewPointDiff } STATUS current DESCRIPTION "Basic objects." -- 1.3.6.1.4.1.28507.69.2.1.1 ::= { epc1105Groups 1 } epc1105NotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { epc1105HygroEvtSen, epc1105SwitchEvtPort, epc1105TempEvtSen, epc1105InputEvtSen, epc1105AirPressureEvtSen, epc1105DewPtDiffEvtSen, epc1105LineAmperageEvt } STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.69.2.1.2 ::= { epc1105Groups 2 } -- Notification Types -- events OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.69.3 ::= { gadsEPC1105 3 } epc1105SensorTable OBJECT-TYPE SYNTAX SEQUENCE OF Epc1105SensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.69.1.6.1 ::= { epc1105ExtSensors 1 } epc1105SensorEntry OBJECT-TYPE SYNTAX Epc1105SensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { epc1105SensorIndex } -- 1.3.6.1.4.1.28507.69.1.6.1.1 ::= { epc1105SensorTable 1 } Epc1105SensorEntry ::= SEQUENCE { epc1105SensorIndex Integer32, epc1105TempSensor Integer32, epc1105HygroSensor Integer32, epc1105InputSensor INTEGER, epc1105AirPressure Integer32, epc1105DewPoint Integer32, epc1105DewPointDiff Integer32 } epc1105SensorIndex OBJECT-TYPE SYNTAX Integer32 (1) MAX-ACCESS read-only STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.69.1.6.1.1.1 ::= { epc1105SensorEntry 1 } epc1105TempSensor OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 degree Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "actual temperature" -- 1.3.6.1.4.1.28507.69.1.6.1.1.2 ::= { epc1105SensorEntry 2 } epc1105HygroSensor OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 percent humidity" MAX-ACCESS read-only STATUS current DESCRIPTION "actual humidity" -- 1.3.6.1.4.1.28507.69.1.6.1.1.3 ::= { epc1105SensorEntry 3 } epc1105InputSensor OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "logical state of input sensor" -- 1.3.6.1.4.1.28507.69.1.6.1.1.4 ::= { epc1105SensorEntry 4 } epc1105SwitchEvtPort NOTIFICATION-TYPE OBJECTS { epc1105PortIndex, epc1105PortName, epc1105PortState, epc1105PortSwitchCount} STATUS current DESCRIPTION "Event is triggered when a port is switched" -- 1.3.6.1.4.1.28507.69.3.1 ::= { events 1 } epc1105LineAmperageEvt NOTIFICATION-TYPE OBJECTS { epc1105PowerIndex, epc1105PowerActive, epc1105Current, epc1105Voltage, epc1105Frequency, epc1105PowerApparent, epc1105PowerReactive} STATUS current DESCRIPTION "Event is triggered when a measured current is crossing the entered limits" -- 1.3.6.1.4.1.28507.69.3.7 ::= { events 7 } epc1105TempEvtSen NOTIFICATION-TYPE OBJECTS { epc1105SensorIndex, epc1105TempSensor} STATUS current DESCRIPTION "temperature limits exceeded" -- 1.3.6.1.4.1.28507.69.3.2 ::= { events 2 } epc1105InputEvtSen NOTIFICATION-TYPE OBJECTS { epc1105SensorIndex, epc1105InputSensor} STATUS current DESCRIPTION "change of logical input sensor state" -- 1.3.6.1.4.1.28507.69.3.4 ::= { events 4 } epc1105AirPressureEvtSen NOTIFICATION-TYPE OBJECTS { epc1105SensorIndex, epc1105AirPressure} STATUS current DESCRIPTION "Air Pressure limits exceeded" -- 1.3.6.1.4.1.28507.69.3.5 ::= { events 5 } epc1105DewPtDiffEvtSen NOTIFICATION-TYPE OBJECTS { epc1105SensorIndex, epc1105DewPointDiff} STATUS current DESCRIPTION "Dew Point Difference limits exceeded" -- 1.3.6.1.4.1.28507.69.3.6 ::= { events 6 } epc1105AirPressure OBJECT-TYPE SYNTAX Integer32 UNITS "1 hPA (hectopascal) ~ 1 milibar" MAX-ACCESS read-only STATUS current DESCRIPTION "actual air pressure" -- 1.3.6.1.4.1.28507.69.1.6.1.1.5 ::= { epc1105SensorEntry 5 } epc1105DewPoint OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 degree Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "dew point for actual temperature and humidity" -- 1.3.6.1.4.1.28507.69.1.6.1.1.6 ::= { epc1105SensorEntry 6 } epc1105DewPointDiff OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 degree Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "difference between dew point and actual temperature (Temp - DewPoint)" -- 1.3.6.1.4.1.28507.69.1.6.1.1.7 ::= { epc1105SensorEntry 7 } epc1105HygroEvtSen NOTIFICATION-TYPE OBJECTS { epc1105SensorIndex, epc1105HygroSensor} STATUS current DESCRIPTION "hygro limits exceeded" -- 1.3.6.1.4.1.28507.43.3.4 -- 1.3.6.1.4.1.28507.68.3.3 -- 1.3.6.1.4.1.28507.69.3.3 ::= { events 3 } END