GUDEADS-ENC2302-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Unsigned32 FROM SNMPv2-SMI OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF; gudeads MODULE-IDENTITY LAST-UPDATED "200703051356Z" -- Mar 5, 2007 1:56:00 PM ORGANIZATION "Gude Analog- und Digitalsysteme GmbH" CONTACT-INFO "http://www.gudeads.com/" DESCRIPTION "" REVISION "200703051356Z" -- Mar 5, 2007 1:56:00 PM DESCRIPTION "$Id: GUDEADS-ENC2302-MIB.txt 4232 2011-07-26 09:45:52Z petes1 $" -- 1.3.6.1.4.1.28507 ::= { enterprises 28507 } enc2302SensorTable OBJECT-TYPE SYNTAX SEQUENCE OF Enc2302SensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.70.1.6.1 ::= { enc2302ExtSensors 1 } enc2302SensorEntry OBJECT-TYPE SYNTAX Enc2302SensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { enc2302SensorIndex } -- 1.3.6.1.4.1.28507.70.1.6.1.1 ::= { enc2302SensorTable 1 } Enc2302SensorEntry ::= SEQUENCE { enc2302SensorIndex Integer32, enc2302TempSensor Integer32, enc2302HygroSensor Integer32, enc2302InputSensor INTEGER, enc2302AirPressure Integer32, enc2302DewPoint Integer32, enc2302DewPointDiff Integer32 } enc2302SensorIndex OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.70.1.6.1.1.1 ::= { enc2302SensorEntry 1 } enc2302TempSensor OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 degree Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "actual temperature" -- 1.3.6.1.4.1.28507.70.1.6.1.1.2 ::= { enc2302SensorEntry 2 } enc2302HygroSensor OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 percent humidity" MAX-ACCESS read-only STATUS current DESCRIPTION "actual humidity" -- 1.3.6.1.4.1.28507.70.1.6.1.1.3 ::= { enc2302SensorEntry 3 } enc2302InputSensor OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "logical state of input sensor" -- 1.3.6.1.4.1.28507.70.1.6.1.1.4 ::= { enc2302SensorEntry 4 } enc2302AirPressure OBJECT-TYPE SYNTAX Integer32 UNITS "1 hPA (hectopascal) ~ 1 milibar" MAX-ACCESS read-only STATUS current DESCRIPTION "actual air pressure" -- 1.3.6.1.4.1.28507.70.1.6.1.1.5 ::= { enc2302SensorEntry 5 } enc2302DewPoint OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 degree Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "dew point for actual temperature and humidity" -- 1.3.6.1.4.1.28507.70.1.6.1.1.6 ::= { enc2302SensorEntry 6 } enc2302DewPointDiff OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 degree Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "difference between dew point and actual temperature (Temp - DewPoint)" -- 1.3.6.1.4.1.28507.70.1.6.1.1.7 ::= { enc2302SensorEntry 7 } gadsENC2302 OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.70 ::= { gudeads 70 } -- Scalars and Tables -- enc2302Objects OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.70.1 ::= { gadsENC2302 1 } enc2302CommonConfig OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.70.1.1 ::= { enc2302Objects 1 } enc2302SNMPaccess OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.70.1.1.1 ::= { enc2302CommonConfig 1 } enc2302TrapCtrl OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3" -- 1.3.6.1.4.1.28507.70.1.1.1.1 ::= { enc2302SNMPaccess 1 } enc2302TrapIPTable OBJECT-TYPE SYNTAX SEQUENCE OF Enc2302TrapIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "list of all Trap receiver" -- 1.3.6.1.4.1.28507.70.1.1.1.2 ::= { enc2302SNMPaccess 2 } enc2302TrapIPEntry OBJECT-TYPE SYNTAX Enc2302TrapIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "an entry containing management informations regarding the list of trap receivers" INDEX { enc2302TrapIPIndex } -- 1.3.6.1.4.1.28507.70.1.1.1.2.1 ::= { enc2302TrapIPTable 1 } Enc2302TrapIPEntry ::= SEQUENCE { enc2302TrapIPIndex Integer32, enc2302TrapAddr OCTET STRING } enc2302TrapIPIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each receiver slot." -- 1.3.6.1.4.1.28507.70.1.1.1.2.1.1 ::= { enc2302TrapIPEntry 1 } enc2302TrapAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..99)) MAX-ACCESS read-write STATUS current DESCRIPTION "DNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot." -- 1.3.6.1.4.1.28507.70.1.1.1.2.1.2 ::= { enc2302TrapIPEntry 2 } enc2302DeviceConfig OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.70.1.2 ::= { enc2302Objects 2 } enc2302IntActors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.70.1.3 ::= { enc2302Objects 3 } enc2302relayports OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.70.1.3.1 ::= { enc2302IntActors 1 } enc2302portNumber OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Relay Ports" -- 1.3.6.1.4.1.28507.70.1.3.1.1 ::= { enc2302relayports 1 } -- the Interfaces table -- The Interfaces table contains information on the entity's -- interfaces. Each sub-layer below the internetwork-layer -- of a network interface is considered to be an interface. enc2302portTable OBJECT-TYPE SYNTAX SEQUENCE OF Enc2302portEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "list of all EPC Relay Ports" -- 1.3.6.1.4.1.28507.70.1.3.1.2 ::= { enc2302relayports 2 } enc2302portEntry OBJECT-TYPE SYNTAX Enc2302portEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular relay port." INDEX { enc2302PortIndex } -- 1.3.6.1.4.1.28507.70.1.3.1.2.1 ::= { enc2302portTable 1 } Enc2302portEntry ::= SEQUENCE { enc2302PortIndex Integer32, enc2302PortName OCTET STRING, enc2302PortState INTEGER, enc2302PortSwitchCount Integer32, enc2302PortStartupMode INTEGER, enc2302PortStartupDelay Integer32, enc2302PortRepowerTime Integer32 } enc2302PortIndex OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value, greater than zero, for each Relay Port." -- 1.3.6.1.4.1.28507.70.1.3.1.2.1.1 ::= { enc2302portEntry 1 } enc2302PortName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-write STATUS current DESCRIPTION "A textual string containing name of a Relay Port." -- 1.3.6.1.4.1.28507.70.1.3.1.2.1.2 ::= { enc2302portEntry 2 } enc2302PortState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "current state a Relay Port" -- 1.3.6.1.4.1.28507.70.1.3.1.2.1.3 ::= { enc2302portEntry 3 } enc2302PortSwitchCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of switch actions ocurred on a Relay Port. Does not count switch commands which will not switch the ralay state, so just real relay switches are displayed here." -- 1.3.6.1.4.1.28507.70.1.3.1.2.1.4 ::= { enc2302portEntry 4 } enc2302PortStartupMode OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), laststate(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "set Mode of startup sequence (off, on , remember last state)" DEFVAL { off } -- 1.3.6.1.4.1.28507.70.1.3.1.2.1.5 ::= { enc2302portEntry 5 } enc2302PortStartupDelay OBJECT-TYPE SYNTAX Integer32 UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Delay in sec for startup action" DEFVAL { 0 } -- 1.3.6.1.4.1.28507.70.1.3.1.2.1.6 ::= { enc2302portEntry 6 } enc2302PortRepowerTime OBJECT-TYPE SYNTAX Integer32 (0..65535) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Delay in sec for repower port after switching off" DEFVAL { 0 } -- 1.3.6.1.4.1.28507.70.1.3.1.2.1.7 ::= { enc2302portEntry 7 } enc2302ExtActors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.70.1.4 ::= { enc2302Objects 4 } enc2302IntSensors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.70.1.5 ::= { enc2302Objects 5 } enc2302ExtSensors OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.70.1.6 ::= { enc2302Objects 6 } enc2302Inputs OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.70.1.5.6 ::= { enc2302IntSensors 6 } enc2302ActiveInputs OBJECT-TYPE SYNTAX Unsigned32 (1) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of suppported Input Channels." -- 1.3.6.1.4.1.28507.70.1.5.6.1 ::= { enc2302Inputs 1 } enc2302InputTable OBJECT-TYPE SYNTAX SEQUENCE OF Enc2302InputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.70.1.5.6.2 ::= { enc2302Inputs 2 } enc2302InputEntry OBJECT-TYPE SYNTAX Enc2302InputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { enc2302InputIndex } -- 1.3.6.1.4.1.28507.70.1.5.6.2.1 ::= { enc2302InputTable 1 } Enc2302InputEntry ::= SEQUENCE { enc2302InputIndex Integer32, enc2302Input INTEGER } enc2302InputIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.70.1.5.6.2.1.1 ::= { enc2302InputEntry 1 } enc2302Input OBJECT-TYPE SYNTAX INTEGER { lo(0), hi(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Input state of device" -- 1.3.6.1.4.1.28507.70.1.5.6.2.1.2 ::= { enc2302InputEntry 2 } -- Conformance -- enc2302Conf OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.70.2 ::= { gadsENC2302 2 } -- Groups -- enc2302Groups OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.70.2.1 ::= { enc2302Conf 1 } -- Compliance -- enc2302Compls OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.70.2.2 ::= { enc2302Conf 2 } enc2302BasicGroup OBJECT-GROUP OBJECTS { enc2302TrapCtrl, enc2302TrapIPIndex, enc2302TrapAddr, enc2302portNumber, enc2302PortIndex, enc2302PortName, enc2302PortState, enc2302PortSwitchCount, enc2302PortStartupMode, enc2302PortStartupDelay, enc2302PortRepowerTime, enc2302ActiveInputs, enc2302InputIndex, enc2302Input, enc2302SensorIndex, enc2302TempSensor, enc2302HygroSensor, enc2302InputSensor, enc2302AirPressure, enc2302DewPoint, enc2302DewPointDiff } STATUS current DESCRIPTION "Basic objects." -- 1.3.6.1.4.1.28507.70.2.1.1 ::= { enc2302Groups 1 } enc2302NotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { enc2302SwitchEvtPort, enc2302InputEvt, enc2302TempEvtSen, enc2302HygroEvtSen, enc2302InputEvtSen, enc2302AirPressureEvtSen, enc2302DewPtDiffEvtSen } STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.70.2.1.2 ::= { enc2302Groups 2 } -- Notification Types -- events OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.70.3 ::= { gadsENC2302 3 } enc2302InputEvt NOTIFICATION-TYPE OBJECTS { enc2302InputIndex, enc2302Input} STATUS current DESCRIPTION "Change of device input." -- 1.3.6.1.4.1.28507.70.3.2 ::= { events 2 } enc2302HygroEvtSen NOTIFICATION-TYPE OBJECTS { enc2302SensorIndex, enc2302HygroSensor} STATUS current DESCRIPTION "hygro limits exceeded" -- 1.3.6.1.4.1.28507.70.3.4 ::= { events 4 } enc2302InputEvtSen NOTIFICATION-TYPE OBJECTS { enc2302SensorIndex, enc2302InputSensor} STATUS current DESCRIPTION "change of logical input sensor state" -- 1.3.6.1.4.1.28507.70.3.5 ::= { events 5 } enc2302AirPressureEvtSen NOTIFICATION-TYPE OBJECTS { enc2302SensorIndex, enc2302AirPressure} STATUS current DESCRIPTION "Air Pressure limits exceeded " -- 1.3.6.1.4.1.28507.70.3.6 ::= { events 6 } enc2302DewPtDiffEvtSen NOTIFICATION-TYPE OBJECTS { enc2302SensorIndex, enc2302DewPointDiff} STATUS current DESCRIPTION "Dew Point Difference limits exceeded" -- 1.3.6.1.4.1.28507.70.3.7 ::= { events 7 } enc2302TempEvtSen NOTIFICATION-TYPE OBJECTS { enc2302SensorIndex, enc2302TempSensor} STATUS current DESCRIPTION "temperature limits exceeded" -- 1.3.6.1.4.1.28507.70.3.3 ::= { events 3 } enc2302SwitchEvtPort NOTIFICATION-TYPE OBJECTS { enc2302PortIndex, enc2302PortName, enc2302PortState, enc2302PortSwitchCount} STATUS current DESCRIPTION "Event is triggered when a port is switched" -- 1.3.6.1.4.1.28507.70.3.1 ::= { events 1 } END