-- ======================================================================= -- File : FIBROLAN-ATOMIC-CLOCK-MIB.mib -- Description : Private MIB file for Fibrolan Atomic Clock feature -- Author : Shamir Stein -- -- Copyright Fibrolan, 2015. All rights reserved. -- -- Reproduction of this document is authorized on condition that this -- copyright notice is included. -- ======================================================================= FIBROLAN-ATOMIC-CLOCK-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, MODULE-IDENTITY, Integer32, TimeTicks, NOTIFICATION-TYPE FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC fibrolanGeneric FROM FIBROLAN-COMMON-MIB; flAtomicClock MODULE-IDENTITY LAST-UPDATED "201509150000Z" ORGANIZATION "Fibrolan Ltd." CONTACT-INFO "support@fibrolan.com" DESCRIPTION "The MIB module to describe Fibrolan's Atomic Clock feature. This module includes the relevant traps as well. This module is part of Fibrolan's group of generic MIB modules (i.e. can be supported on different devices). Copyright (C) Fibrolan Ltd. (2015)." REVISION "201509150000Z" DESCRIPTION "Merged inventory and status tables. Changed last changed object type to TimeTicks. Added ranges to objects where applicable. Misc cleanup." REVISION "201508150000Z" DESCRIPTION "Initial version (version 1)." ::= { fibrolanGeneric 220 } flAtomicClockNotifications OBJECT IDENTIFIER ::= { flAtomicClock 0 } flAtomicClockMIBObjects OBJECT IDENTIFIER ::= { flAtomicClock 1 } -- ************************************************************ -- Atomic Clock module main table -- ************************************************************ flAtomicClockTable OBJECT-TYPE SYNTAX SEQUENCE OF FlAtomicClockEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This tables provides inventory and status details on the Atomic Clock module and oscillator." ::= { flAtomicClockMIBObjects 10 } flAtomicClockEntry OBJECT-TYPE SYNTAX FlAtomicClockEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entries of the Atomic Clock module table." INDEX { flAtomicClockModuleId } ::= { flAtomicClockTable 1 } FlAtomicClockEntry ::= SEQUENCE { flAtomicClockModuleId Integer32, flAtomicClockModuleType DisplayString, flAtomicClockModulePartNumber DisplayString, flAtomicClockModuleSerialNumber DisplayString, flAtomicClockOscillatorType INTEGER, flAtomicClockOscillatorPartNumber DisplayString, flAtomicClockOscillatorSerialNumber DisplayString, flAtomicClockOscillatorFwVersion DisplayString, flAtomicClockState INTEGER, flAtomicClockStateLastChange TimeTicks, flAtomicClockTemperature Integer32, flAtomicClockTemperatureAlarmState INTEGER, flAtomicClockCellHeaterCurrent Integer32, flAtomicClockCellHeaterCurrentAlarmState INTEGER, flAtomicClockAdjustPp15 Integer32 } flAtomicClockModuleId OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Atomic Clock module ID (index)." ::= { flAtomicClockEntry 1 } flAtomicClockModuleType OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Atomic Clock module type (e.g. RBCM-1)." ::= { flAtomicClockEntry 2 } flAtomicClockModulePartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Atomic Clock module part number." ::= { flAtomicClockEntry 3 } flAtomicClockModuleSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Atomic Clock module serial number." ::= { flAtomicClockEntry 4 } flAtomicClockOscillatorType OBJECT-TYPE SYNTAX INTEGER { rubidium (1), cesium (2), other (99) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Atomic Clock oscillator type." ::= { flAtomicClockEntry 5 } flAtomicClockOscillatorPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Atomic Clock oscillator part number." ::= { flAtomicClockEntry 6 } flAtomicClockOscillatorSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Atomic Clock oscillator serial number." ::= { flAtomicClockEntry 7 } flAtomicClockOscillatorFwVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Atomic Clock oscillator FW version." ::= { flAtomicClockEntry 8 } flAtomicClockState OBJECT-TYPE SYNTAX INTEGER { unplugged (1), warming (2), ppsShifting (3), shortTermSteering (4), averaging (5), longTermSteering (6), holdover (7), holdoverRecovery (8), freeRunning (9), other (99) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the Atomic Clock module. Under normal conditions, from power up, the state sequence should move from unplugged (may be skipped) to warming, ready, ppsShifting, shortTermSteering, averaging (will stay a while in this state) and eventually longTermSteering. In the latter two states, the module is holdover ready. When primary reference (e.g. GPS) is lost, the state should change to holdover, and when holdover is no longer valid state will move to free-running. Normally, 'other' state should not be present." ::= { flAtomicClockEntry 9 } flAtomicClockStateLastChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of MIB II's sysUpTime object at the time the module entered its current state." ::= { flAtomicClockEntry 10 } flAtomicClockTemperature OBJECT-TYPE SYNTAX Integer32 (-128..127) MAX-ACCESS read-only STATUS current DESCRIPTION "The current temperature of the Atomic Clock module/oscillator. Value is in degrees Celsius." ::= { flAtomicClockEntry 11 } flAtomicClockTemperatureAlarmState OBJECT-TYPE SYNTAX INTEGER { normal (1), warning (2), error (3), other (99) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current temperature alarm state of the Atomic Clock module/oscillator. Should normally return 'normal'. A value of 'warning' means the module is still functional within the correct operational range, but may suffer failure if current conditions do not change for the better. An 'error' condition means the module may currently be experiencing a failure condition, or such may occur at any time (i.e. module too close to operational range)." ::= { flAtomicClockEntry 12 } flAtomicClockCellHeaterCurrent OBJECT-TYPE SYNTAX Integer32 (0..3000) MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Cell Heater Current of the Atomic Clock oscillator (when applicable). Value is in [mA]." ::= { flAtomicClockEntry 13 } flAtomicClockCellHeaterCurrentAlarmState OBJECT-TYPE SYNTAX INTEGER { normal (1), warning (2), error (3), other (99) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current cell heater current alarm state of the Atomic Clock module/oscillator. Should normally return 'normal'. A value of 'warning' means the module is still functional within the correct operational range, but may suffer failure if current conditions do not change for the better. An 'error' condition means the module may currently be experiencing a failure condition, or such may occur at any time (i.e. module too close to operational range)." ::= { flAtomicClockEntry 14 } flAtomicClockAdjustPp15 OBJECT-TYPE SYNTAX Integer32 (-10000000..10000000) MAX-ACCESS read-only STATUS current DESCRIPTION "The current digital adjust value of the Atomic Clock (when applicable). This object may be ignored by users and is mostly used for internal monitoring and diagnostics. Value is in [pp15] (1E-15)." ::= { flAtomicClockEntry 15 } -- ************************************************************ -- Atomic clock traps (notifications) -- ************************************************************ flAtomicClockStateChange NOTIFICATION-TYPE OBJECTS { flAtomicClockState } STATUS current DESCRIPTION "Indicates the Atomic Clock has changed state." ::= { flAtomicClockNotifications 10 } flAtomicClockTemperatureAlarmStateChange NOTIFICATION-TYPE OBJECTS { flAtomicClockTemperatureAlarmState } STATUS current DESCRIPTION "Indicates the Atomic Clock temperature alarm state has changed." ::= { flAtomicClockNotifications 20 } END