ENTERASYS-TRANSMIT-QUEUE-MONITOR-MIB DEFINITIONS ::= BEGIN -- enterasys-transmit-queue-monitor-mib.txt -- -- Part Number: -- -- -- This module provides authoritative definitions for Enterasys -- Networks' Transmit Queue Monitor MIB -- -- This module will be extended, as needed. -- Enterasys Networks reserves the right to make changes in this -- specification and other information contained in this document -- without prior notice. The reader should consult Enterasys Networks -- to determine whether any such changes have been made. -- -- In no event shall Enterasys Networks be liable for any incidental, -- indirect, special, or consequential damages whatsoever (including -- but not limited to lost profits) arising out of or related to this -- document or the information contained in it, even if Enterasys -- Networks has been advised of, known, or should have known, the -- possibility of such damages. -- -- Enterasys Networks grants vendors, end-users, and other interested -- parties a non-exclusive license to use this Specification in -- connection with the management of Enterasys Networks products. -- Copyright February, 2013 Enterasys Networks, Inc. IMPORTS MODULE-IDENTITY, OBJECT-TYPE,Integer32, Counter64, NOTIFICATION-TYPE FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF ifIndex, ifName FROM IF-MIB TruthValue FROM SNMPv2-TC etsysModules FROM ENTERASYS-MIB-NAMES; etsysTxqMonitorMIB MODULE-IDENTITY LAST-UPDATED "201302251627Z" -- Mon Feb 25 16:27 UTC 2013 ORGANIZATION "Enterasys Networks, Inc" CONTACT-INFO "Postal: Enterasys Networks 9 Northeastern Blvd Salem, NH 03079 USA Phone: +1 978 684 1000 E-mail: support@enterasys.com WWW: http://www.enterasys.com" DESCRIPTION "This MIB module defines a portion of the SNMP MIB under the Enterasys Networks enterprise OID pertaining to the Transmit Queue Monitor MIB." REVISION "201302251627Z" -- Mon Feb 25 16:27 UTC 2013 DESCRIPTION "Initial version of this MIB module." ::= { etsysModules 99 } -- -------------------------------------------------------------- -- -- branches in the ENTERASYS-TRANSMIT-QUEUE-MONITOR-MIB DEFINITIONS -- -------------------------------------------------------------- -- etsysTxqMonitorObjects OBJECT IDENTIFIER ::= { etsysTxqMonitorMIB 1 } etsysTxqMonitorNotifications OBJECT IDENTIFIER ::= { etsysTxqMonitorObjects 0 } etsysTxqMonitor OBJECT IDENTIFIER ::= { etsysTxqMonitorObjects 1 } etsysTxqMonitorPort OBJECT IDENTIFIER ::= { etsysTxqMonitorObjects 2 } -- ------------------------------------------------------------- -- Objects in the etsysTxqMonitor -- ------------------------------------------------------------- etsysTxqMonitorDownTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of sample intervals that ports disabled by Transmit Queue Monitor may be held down. A value of zero will set the down time to forever." DEFVAL { 0 } ::= { etsysTxqMonitor 1 } etsysTxqMonitorIgnorePauseTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of sample intervals that ports ignoring RX pause by Transmit Queue Monitor may be held in this state. A value of zero will set the ignore RX pause time to forever." DEFVAL { 0 } ::= { etsysTxqMonitor 2 } etsysTxqMonitorMinRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The minimum rate of transmitted packets in a sampling interval." DEFVAL { 1 } ::= { etsysTxqMonitor 3 } etsysTxqMonitorSampleInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The rate(in seconds) that the transmit queues will be checked for stalled buffers." DEFVAL { 1 } ::= { etsysTxqMonitor 4 } etsysTxqMonitorTrapStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Trap status for transmit queue monitoring. When enabled, traps will be sent when each of enabled thresholds are reached." DEFVAL { 2 } ::= { etsysTxqMonitor 5 } etsysTxqMonitorLoggingThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Threshold levels for the number of sequential failures before triggering logging action. A value of 0 disables the action." DEFVAL { 2 } ::= { etsysTxqMonitor 6 } etsysTxqMonitorIgnorePauseThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Threshold levels for the number of sequential failures before triggering ignore pause action. A value of 0 disables the action." DEFVAL { 5 } ::= { etsysTxqMonitor 7 } etsysTxqMonitorDisablePortThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Threshold levels for the number of sequential failures before triggering disable port action. A value of 0 disables the action." DEFVAL { 10 } ::= { etsysTxqMonitor 8 } etsysTxqMonitorEnableState OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Transmit monitoring global state. If enabled(1), all ports will monitor the transmit queues for stalled ports. If a port is detected as stalled, the configured action will take effect." DEFVAL { 1 } ::= { etsysTxqMonitor 9 } etsysTxqMonitorPortTable OBJECT-TYPE SYNTAX SEQUENCE OF EtsysTxqMonitorPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing the Transmit Queue Monitoring port state." ::= { etsysTxqMonitorPort 1 } etsysTxqMonitorPortEntry OBJECT-TYPE SYNTAX EtsysTxqMonitorPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Port Table contains Transmit Queue Monitor operational status and state." INDEX { ifIndex } ::= { etsysTxqMonitorPortTable 1 } EtsysTxqMonitorPortEntry ::= SEQUENCE { etsysTxqMonitorPortConsecutiveStalled Counter64, etsysTxqMonitorPortTotalStalled Counter64, etsysTxqMonitorPortOperationalStatus INTEGER, etsysTxqMonitorPortReset TruthValue, etsysTxqMonitorPortCapabilities BITS } etsysTxqMonitorPortConsecutiveStalled OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the port has reached a stalled state consecutively." ::= { etsysTxqMonitorPortEntry 1 } etsysTxqMonitorPortTotalStalled OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of times the port has reached a stalled state." ::= { etsysTxqMonitorPortEntry 2 } etsysTxqMonitorPortOperationalStatus OBJECT-TYPE SYNTAX INTEGER { disabled(1), normal(2), logging(3), ignorePause(4), down(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Transit Queue Monitor operational state. disabled(1) - Transmit queue monitoring is not running on this port. normal(2) - Transmit queue monitoring is currently monitoring this port and there are no stalled buffers. logging(3) - Transmit queue monitoring has detected a stalled buffer and is currently logging the condition. ignorePause(4) - Transmit queue monitoring has disabled the processing of received pause packets. down(5) Transmit queue monitoring has taken this port down. " ::= { etsysTxqMonitorPortEntry 3 } etsysTxqMonitorPortReset OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This value shall always read false. When set to true, this object will clear any actions currently being taken by the transmit queue monitor and the ports etsysTxqMonitorPortOperationalStatus will be set to normal if transmit queue monitoring is enabled otherwise disabled." DEFVAL { false } ::= { etsysTxqMonitorPortEntry 4 } etsysTxqMonitorPortCapabilities OBJECT-TYPE SYNTAX BITS { logging(0), ignorePause(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object defines the capabilities the port supports for actions to be taken when a stalled port has been detected." ::= { etsysTxqMonitorPortEntry 5 } -- ------------------------------------------------------------- -- Notifications -- ------------------------------------------------------------- etsysTxqMonitorLoggingNotification NOTIFICATION-TYPE OBJECTS { ifName, etsysTxqMonitorLoggingThreshold } STATUS current DESCRIPTION "This notification indicates that the port has exceeded its logging threshold." ::= { etsysTxqMonitorNotifications 1 } etsysTxqMonitorIgnorePauseNotification NOTIFICATION-TYPE OBJECTS { ifName, etsysTxqMonitorIgnorePauseThreshold } STATUS current DESCRIPTION "This notification indicates that the port has exceeded its ignore pause threshold." ::= { etsysTxqMonitorNotifications 2 } etsysTxqMonitorDisablePortNotification NOTIFICATION-TYPE OBJECTS { ifName, etsysTxqMonitorDisablePortThreshold } STATUS current DESCRIPTION "This notification indicates that the port has exceeded its disable port threshold." ::= { etsysTxqMonitorNotifications 3 } -- ------------------------------------------------------------- -- Conformance Information -- ------------------------------------------------------------- etsysTxqMonitorConformance OBJECT IDENTIFIER ::= { etsysTxqMonitorMIB 2 } etsysTxqMonitorGroups OBJECT IDENTIFIER ::= { etsysTxqMonitorConformance 1 } etsysTxqMonitorCompliances OBJECT IDENTIFIER ::= { etsysTxqMonitorConformance 2 } -- ------------------------------------------------------------- -- Units of conformance -- ------------------------------------------------------------- etsysTxqMonitorSettings OBJECT-GROUP OBJECTS { etsysTxqMonitorDownTime, etsysTxqMonitorIgnorePauseTime, etsysTxqMonitorMinRate, etsysTxqMonitorSampleInterval, etsysTxqMonitorTrapStatus, etsysTxqMonitorLoggingThreshold, etsysTxqMonitorIgnorePauseThreshold, etsysTxqMonitorDisablePortThreshold, etsysTxqMonitorEnableState, etsysTxqMonitorPortConsecutiveStalled, etsysTxqMonitorPortTotalStalled, etsysTxqMonitorPortOperationalStatus, etsysTxqMonitorPortReset, etsysTxqMonitorPortCapabilities } STATUS current DESCRIPTION "A collection of objects for configuring and reporting Transmit Queue Monitoring." ::= {etsysTxqMonitorGroups 1 } etsysTxqMonitorNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { etsysTxqMonitorLoggingNotification, etsysTxqMonitorIgnorePauseNotification, etsysTxqMonitorDisablePortNotification } STATUS current DESCRIPTION "A collection of objects required for reporting exceeding transmit queue monitoring thresholds." ::= { etsysTxqMonitorGroups 2 } etsysTxqMonitorComplianceGroup MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for devices that support the Enterasys Transmit Queue Monitor MIB." MODULE MANDATORY-GROUPS { etsysTxqMonitorSettings, etsysTxqMonitorNotificationGroup } ::= { etsysTxqMonitorCompliances 1} END