ELTEX-PHY-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32 FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString, TruthValue FROM SNMPv2-TC ifIndex FROM IF-MIB eltexLtd FROM ELTEX-SMI-ACTUAL; eltexPhyMIB MODULE-IDENTITY LAST-UPDATED "202010150000Z" -- Oct 15 00:00:00 GMT 2020 ORGANIZATION "Eltex Enterprise Co, Ltd." CONTACT-INFO "www.eltex-co.ru" DESCRIPTION "The MIB module describes the private MIB for L1 testing." REVISION "202010150000Z" DESCRIPTION "Added cross-pair tests for EltexPhyTestGetType." REVISION "201810300000Z" DESCRIPTION "Initial revision." ::= { eltexLtd 52 } ------------------------------------------------------------------------------- -- Textual Conventions. EltexPhyTransConnectorType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Transceiver connector type." SYNTAX INTEGER { unknown(0), sc(1), fibre-ch-st1(2), fibre-ch-st2(3), bnc-tnc(4), fibre-ch-coaxial-headers(5), fibrejack(6), lc(7), mt-rj(8), mu(9), sg(10), optical-pigtail(11), mpo-parallel-optic(12), hssdc-ii(32), copper-pigtail(33), rj45(34), no-separable-connector(35), unallocated(127), vendorspec(255) } EltexPhyTransType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Transceiver type." SYNTAX INTEGER { unknown(0), gbic(1), sff(2), sfp-sfpplus(3), xbi-300-pin(4), xenpak(5), xfp(6), xff(7), xfp-e(8), xpak(9), x2(10), dwdm-sfp(11), qsfp(12), qsfpplus(13), reserved(127), vendorspec(255) } EltexPhyTransFiberDiameter ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The diameter of the fiber, measured in micron. fiber9 - 9 micron multi-mode fiber fiber50 - 50 micron multi-mode fiber fiber625 - 62.5 micron multi-mode fiber copper - copper cable." SYNTAX INTEGER { fiber9(1), fiber50(2), fiber625(3), copper(4), unknown(65535) } EltexPhyTransDiagnosticType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Transceiver diagnostic type." SYNTAX INTEGER { temperature(1), supplyVoltage(2), txBiasCurrent(3), txOpticalPower(4), rxOpticalPower(5), lossOfSignal(6) } EltexPhyTestSetType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A value indicating the test to perform." SYNTAX INTEGER { cableStatus(1) -- long accurate test with link down } EltexPhyTestGetStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Status of test" SYNTAX INTEGER { none(1), -- no test yet requested success(2), inProgress(3), notSupported(4), unableToRun(5), -- due to state of system aborted(6), failed(7) } EltexPhyTestGetUnits ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Units of test" SYNTAX INTEGER { integer(1), boolean(2), meter(3) } EltexPhyTestGetType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A value indicating the performed test." SYNTAX INTEGER { channelAShort(1), channelBShort(2), channelCShort(3), channelDShort(4), channelAOpen(5), channelBOpen(6), channelCOpen(7), channelDOpen(8), channelAMismatch(9), channelBMismatch(10), channelCMismatch(11), channelDMismatch(12), channelALineDriver(13), channelBLineDriver(14), channelCLineDriver(15), channelDLineDriver(16), channelALength(17), channelBLength(18), channelCLength(19), channelDLength(20), channelACross(21), channelBCross(22), channelCCross(23), channelDCross(24) } ------------------------------------------------------------------------------- eltexPhyObjects OBJECT IDENTIFIER ::= { eltexPhyMIB 1 } eltexPhyTransceiverObjects OBJECT IDENTIFIER ::= { eltexPhyObjects 1 } eltexPhyTestObjects OBJECT IDENTIFIER ::= { eltexPhyObjects 2 } eltexPhyTransceiverGlobals OBJECT IDENTIFIER ::= { eltexPhyTransceiverObjects 1 } eltexPhyTransceiverConfigs OBJECT IDENTIFIER ::= { eltexPhyTransceiverObjects 2 } eltexPhyTransceiverStatistics OBJECT IDENTIFIER ::= { eltexPhyTransceiverObjects 3 } eltexPhyTestGlobals OBJECT IDENTIFIER ::= { eltexPhyTestObjects 1 } ------------------------------------------------------------------------------- -- -- Transceiver information tadle. -- eltexPhyTransceiverInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF EltexPhyTransceiverInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table show the information of interfaces transceivers." ::= { eltexPhyTransceiverStatistics 1 } eltexPhyTransceiverInfoEntry OBJECT-TYPE SYNTAX EltexPhyTransceiverInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry of the eltexPhyTransceiverInfoTable." INDEX { ifIndex } ::= { eltexPhyTransceiverInfoTable 1 } EltexPhyTransceiverInfoEntry ::= SEQUENCE { eltexPhyTransceiverInfoConnectorType EltexPhyTransConnectorType, eltexPhyTransceiverInfoType EltexPhyTransType, eltexPhyTransceiverInfoComplianceCode OCTET STRING, eltexPhyTransceiverInfoWaveLength Integer32, eltexPhyTransceiverInfoVendorName OCTET STRING, eltexPhyTransceiverInfoSerialNumber OCTET STRING, eltexPhyTransceiverInfoFiberDiameter EltexPhyTransFiberDiameter, eltexPhyTransceiverInfoTransferDistance Integer32, eltexPhyTransceiverInfoDiagnosticSupported TruthValue, eltexPhyTransceiverInfoPartNumber OCTET STRING, eltexPhyTransceiverInfoVendorRevision OCTET STRING } eltexPhyTransceiverInfoConnectorType OBJECT-TYPE SYNTAX EltexPhyTransConnectorType MAX-ACCESS read-only STATUS current DESCRIPTION "Connector type of the interface transceiver." ::= { eltexPhyTransceiverInfoEntry 1 } eltexPhyTransceiverInfoType OBJECT-TYPE SYNTAX EltexPhyTransType MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the interface transceiver." ::= { eltexPhyTransceiverInfoEntry 2 } eltexPhyTransceiverInfoComplianceCode OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Compliance code of the interface transceiver." ::= { eltexPhyTransceiverInfoEntry 3 } eltexPhyTransceiverInfoWaveLength OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Wave length of the interface transceiver, measured in nanometer." ::= { eltexPhyTransceiverInfoEntry 4 } eltexPhyTransceiverInfoVendorName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Vendor name of the interface transceiver." ::= { eltexPhyTransceiverInfoEntry 5 } eltexPhyTransceiverInfoSerialNumber OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number of the interface transceiver." ::= { eltexPhyTransceiverInfoEntry 6 } eltexPhyTransceiverInfoFiberDiameter OBJECT-TYPE SYNTAX EltexPhyTransFiberDiameter MAX-ACCESS read-only STATUS current DESCRIPTION "Fiber diameter of the interface transceiver." ::= { eltexPhyTransceiverInfoEntry 7 } eltexPhyTransceiverInfoTransferDistance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximal distance which the interface transceiver could transmit, measured in meter." ::= { eltexPhyTransceiverInfoEntry 8 } eltexPhyTransceiverInfoDiagnosticSupported OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicating whether the digital diagnostic monitoring function is supported or not on the interface transceiver." ::= { eltexPhyTransceiverInfoEntry 9 } eltexPhyTransceiverInfoPartNumber OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Part number of the interface transceiver provided by SFP vendor." ::= { eltexPhyTransceiverInfoEntry 10 } eltexPhyTransceiverInfoVendorRevision OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Revision level for part number provided by vendor." ::= { eltexPhyTransceiverInfoEntry 11 } ------------------------------------------------------------------------------- -- -- Transceiver DDM values and thresholds. -- eltexPhyTransceiverDiagnosticTable OBJECT-TYPE SYNTAX SEQUENCE OF EltexPhyTransceiverDiagnosticEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table show current DDM values and thresholds of the interface transceiver." ::= { eltexPhyTransceiverStatistics 2 } eltexPhyTransceiverDiagnosticEntry OBJECT-TYPE SYNTAX EltexPhyTransceiverDiagnosticEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry of the eltexPhyTransceiverDiagnosticTable." INDEX { ifIndex, eltexPhyTransceiverDiagnosticType, eltexPhyTransceiverDiagnosticChannel } ::= { eltexPhyTransceiverDiagnosticTable 1 } EltexPhyTransceiverDiagnosticEntry ::= SEQUENCE { eltexPhyTransceiverDiagnosticType EltexPhyTransDiagnosticType, eltexPhyTransceiverDiagnosticChannel INTEGER, eltexPhyTransceiverDiagnosticUnits DisplayString, eltexPhyTransceiverDiagnosticHighAlarmThreshold INTEGER, eltexPhyTransceiverDiagnosticHighWarningThreshold INTEGER, eltexPhyTransceiverDiagnosticLowWarningThreshold INTEGER, eltexPhyTransceiverDiagnosticLowAlarmThreshold INTEGER, eltexPhyTransceiverDiagnosticCurrentValue INTEGER } eltexPhyTransceiverDiagnosticType OBJECT-TYPE SYNTAX EltexPhyTransDiagnosticType MAX-ACCESS not-accessible STATUS current DESCRIPTION "Type of the transceiver diagnostic." ::= { eltexPhyTransceiverDiagnosticEntry 1 } eltexPhyTransceiverDiagnosticChannel OBJECT-TYPE SYNTAX INTEGER (1..4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Transceiver channel number." ::= { eltexPhyTransceiverDiagnosticEntry 2 } eltexPhyTransceiverDiagnosticUnits OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Unit of measure for current diagnostic type." ::= { eltexPhyTransceiverDiagnosticEntry 3 } eltexPhyTransceiverDiagnosticHighAlarmThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Transceiver HighAlarm threshold for current diagnostic type." ::= { eltexPhyTransceiverDiagnosticEntry 4 } eltexPhyTransceiverDiagnosticHighWarningThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Transceiver HighWarning threshold for current diagnostic type." ::= { eltexPhyTransceiverDiagnosticEntry 5 } eltexPhyTransceiverDiagnosticLowWarningThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Transceiver LowWarning threshold for current diagnostic type." ::= { eltexPhyTransceiverDiagnosticEntry 6 } eltexPhyTransceiverDiagnosticLowAlarmThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Transceiver LowAlarm threshold for current diagnostic type." ::= { eltexPhyTransceiverDiagnosticEntry 7 } eltexPhyTransceiverDiagnosticCurrentValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Measured value for current transceiver diagnostic type." ::= { eltexPhyTransceiverDiagnosticEntry 8 } ------------------------------------------------------------------------------- -- -- VCT -- eltexPhyTestSetTable OBJECT-TYPE SYNTAX SEQUENCE OF EltexPhyTestSetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing objects for invoking tests on an interface." ::= { eltexPhyTestGlobals 1} eltexPhyTestSetEntry OBJECT-TYPE SYNTAX EltexPhyTestSetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing objects for invoking tests on an interface." INDEX {ifIndex } ::= { eltexPhyTestSetTable 1 } EltexPhyTestSetEntry ::= SEQUENCE { eltexPhyTestSetType EltexPhyTestSetType } eltexPhyTestSetType OBJECT-TYPE SYNTAX EltexPhyTestSetType MAX-ACCESS read-write STATUS current DESCRIPTION "A control variable used to start operator initiated interface tests." ::= { eltexPhyTestSetEntry 1 } eltexPhyTestGetTable OBJECT-TYPE SYNTAX SEQUENCE OF EltexPhyTestGetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing results of tests on an interface." ::= { eltexPhyTestGlobals 2 } eltexPhyTestGetEntry OBJECT-TYPE SYNTAX EltexPhyTestGetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing results of tests on an interface." INDEX {ifIndex, eltexPhyTestGetType} ::= { eltexPhyTestGetTable 1 } EltexPhyTestGetEntry ::= SEQUENCE { eltexPhyTestGetType EltexPhyTestGetType, eltexPhyTestGetStatus EltexPhyTestGetStatus, eltexPhyTestGetResult INTEGER, eltexPhyTestGetUnits EltexPhyTestGetUnits, eltexPhyTestGetTimeStamp DisplayString } eltexPhyTestGetType OBJECT-TYPE SYNTAX EltexPhyTestGetType MAX-ACCESS not-accessible STATUS current DESCRIPTION "The type of test the user performed." ::= { eltexPhyTestGetEntry 1 } eltexPhyTestGetStatus OBJECT-TYPE SYNTAX EltexPhyTestGetStatus MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the status of the most recently requested test for operator initiated tests or the value none(1) if no tests have been requested since the last reset. For non operator initiated tests the value is always none(1). Note that this facility provides no provision for saving the results of one test when starting another, as could be required if used by multiple managers concurrently." ::= { eltexPhyTestGetEntry 2 } eltexPhyTestGetResult OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This object holds the test result" ::= { eltexPhyTestGetEntry 3 } eltexPhyTestGetUnits OBJECT-TYPE SYNTAX EltexPhyTestGetUnits MAX-ACCESS read-only STATUS current DESCRIPTION "The test result unit of measure. The units can be standard unit or special units that are designed for special test." ::= { eltexPhyTestGetEntry 4 } eltexPhyTestGetTimeStamp OBJECT-TYPE SYNTAX DisplayString (SIZE(1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The time in string (formated DD-MMM-YYYY HH:MM:SS e.g 14-Apr-2002 10:33:31)" ::= { eltexPhyTestGetEntry 5 } END