--************************************************************************** -- -- Copyright 2010 Electroline Equipment Inc. -- All Rights Reserved -- -- -- --************************************************************************** -- Filename: ELECTROLINE-DVM-STATUS.mib -- Author: ALAIN LECLERC -- Creation Date: 2010-09-14 -- --************************************************************************** -- Description: -- -- This file contains the MIB definition of the Status branch -- for the DVM products. -- --************************************************************************** -- Revision History: -- 2010-09-14 ALAIN LECLERC First Release --************************************************************************** ELECTROLINE-DVM-STATUS-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY,OBJECT-TYPE,Integer32 FROM SNMPv2-SMI RowStatus FROM SNMPv2-TC dvmStatus, electrolineDVM FROM ELECTROLINE-DVM-ROOT-MIB NetworkAddress FROM RFC1155-SMI DisplayString FROM RFC1213-MIB ifIndex FROM IF-MIB; -- [RFC2863] -- Textual Conventions TenthdBmV ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-1" STATUS current DESCRIPTION "This data type represents power levels that are normally expressed in dBmV. Units are in tenths of a dBmV; for example, 5.1 dBmV will be represented as 51." SYNTAX Integer32 -- Textual Conventions TenthdB ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-1" STATUS current DESCRIPTION "This data type represents the pad value that are normally expressed in dB. Units are in tenths of a dB; for example, 5.1 dB will be represented as 51." SYNTAX Integer32 -- Textual Conventions HundredthsVolts ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-2" STATUS current DESCRIPTION "suggests that a Hundredths value of 1234 be rendered as 12.34 Volts" SYNTAX INTEGER (0..65535) -- ************************************************************************** -- * ELECTROLINE MISC. Statuses -- * -- ************************************************************************** dvmNetworkAddress OBJECT-TYPE SYNTAX NetworkAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is the RF IP address assigned by the DHCP." ::= { dvmStatus 1 } dvmInternalTemperature OBJECT-TYPE SYNTAX INTEGER (-60..130) ACCESS read-only STATUS current DESCRIPTION "Measured temperature inside the NE's case/housing. Units degrees Celsius." ::= { dvmStatus 2 } --************************************************************************** -- Information on the hardware demodulator. -- The DVM has attenuator pad in the downstream path and has a fix -- attenuation pad also. We need to take that in the account for -- downstream and upstream power repport. --************************************************************************** dvmIfDownstreamChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF DvmIfDownstreamChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes the attributes of downstream channels (frequency bands) at Dvm's input." ::= { dvmStatus 3 } dvmIfDownstreamChannelEntry OBJECT-TYPE SYNTAX DvmIfDownstreamChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry provides a list of attributes for a single downstream channel." INDEX { ifIndex } ::= { dvmIfDownstreamChannelTable 1 } DvmIfDownstreamChannelEntry ::= SEQUENCE { dvmIfDownChannelId Integer32, dvmIfDownChannelFrequency Integer32, dvmIfDownChannelWidth Integer32, dvmIfDownChannelModulation INTEGER, dvmIfDownChannelInterleave INTEGER, dvmIfDownChannelPower TenthdBmV, dvmIfDownChannelAnnex INTEGER, dvmIfDownChannelSymbolRate Integer32, dvmIfDownChannelTunerModule Integer32 } dvmIfDownChannelId OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The Cable Modem Termination System identification of the downstream channel within this particular MAC interface. if the interface is down, the object returns the most current value. If the downstream channel ID is unknown, this object returns a value of 0." ::= { dvmIfDownstreamChannelEntry 1 } dvmIfDownChannelFrequency OBJECT-TYPE SYNTAX Integer32 (0..1000000000) UNITS "hertz" MAX-ACCESS read-only STATUS current DESCRIPTION "The center of the downstream frequency associated with this channel. This object will return the current tuner frequency." ::= { dvmIfDownstreamChannelEntry 2 } dvmIfDownChannelWidth OBJECT-TYPE SYNTAX Integer32 (0..16000000) UNITS "hertz" MAX-ACCESS read-only STATUS current DESCRIPTION "The bandwidth of this downstream channel. Most implementations are expected to support a channel width of 6 MHz (North America) and/or 8 MHz (Europe). See the associated compliance object for a description of the valid channel widths for this object." ::= { dvmIfDownstreamChannelEntry 3 } dvmIfDownChannelModulation OBJECT-TYPE SYNTAX INTEGER { unknown(1), other(2), qam64(3), qam256(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The modulation type associated with this downstream channel. If the interface is down, this object either returns the configured value (CMTS), the most current value (CM), or the value of unknown(1). See the associated conformance object for write conditions and limitations. See the reference for specifics on the modulation profiles implied by qam64 and qam256." ::= { dvmIfDownstreamChannelEntry 4 } dvmIfDownChannelInterleave OBJECT-TYPE SYNTAX INTEGER { unknown(1), other(2), taps8Increment16(3), taps16Increment8(4), taps32Increment4(5), taps64Increment2(6), taps128Increment1(7), taps12increment17(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Forward Error Correction (FEC) interleaving used for this downstream channel. Values are defined as follows: taps8Increment16(3): protection 5.9/4.1 usec, latency .22/.15 msec taps16Increment8(4): protection 12/8.2 usec, latency .48/.33 msec taps32Increment4(5): protection 24/16 usec, latency .98/.68 msec taps64Increment2(6): protection 47/33 usec, latency 2/1.4 msec taps128Increment1(7): protection 95/66 usec, latency 4/2.8 msec taps12increment17(8): protection 18/14 usec, latency 0.43/0.32 msec The value 'taps12increment17' is supported by EuroDOCSIS cable systems only, and the others by DOCSIS cable systems. If the interface is down, this object either returns the configured value (CMTS), the most current value (CM), or the value of unknown(1). The value of other(2) is returned if the interleave is known but not defined in the above list. See the associated conformance object for write conditions and limitations. See the reference for the FEC configuration described by the setting of this object." ::= { dvmIfDownstreamChannelEntry 5 } dvmIfDownChannelPower OBJECT-TYPE SYNTAX TenthdBmV UNITS "dBmV" MAX-ACCESS read-only STATUS current DESCRIPTION "At the DVM, the received power level at the RF front-end. If the interface is down, the value of 0." ::= { dvmIfDownstreamChannelEntry 6 } dvmIfDownChannelAnnex OBJECT-TYPE SYNTAX INTEGER { unknown(1), other(2), annexA(3), annexB(4), annexC(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object indicates the conformance of the implementation to important regional cable standards. annexA : Annex A from ITU-T J.83 is used. (equivalent to EN 300 429) annexB : Annex B from ITU-T J.83 is used. annexC : Annex C from ITU-T J.83 is used." ::= { dvmIfDownstreamChannelEntry 7 } dvmIfDownChannelSymbolRate OBJECT-TYPE SYNTAX Integer32 (0..1000000000) MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicates the channel rate in Symbol per second" ::= { dvmIfDownstreamChannelEntry 8 } dvmIfDownChannelTunerModule OBJECT-TYPE SYNTAX Integer32 (-1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object indicates the tuner module number on which the hardware channel is mapped. 1 and 2 are wideband tuners internal to the BCM3380; 3 to 6 are external narrowband tuners -1 unmapped" ::= { dvmIfDownstreamChannelEntry 9 } dvmIfUpstreamChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF DvmIfUpstreamChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes the attributes of attached upstream channels." ::= { dvmStatus 4 } dvmIfUpstreamChannelEntry OBJECT-TYPE SYNTAX DvmIfUpstreamChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of attributes for a single upstream channel." INDEX { ifIndex } ::= { dvmIfUpstreamChannelTable 1 } DvmIfUpstreamChannelEntry ::= SEQUENCE { dvmIfUpChannelId Integer32, dvmIfUpChannelFrequency Integer32, dvmIfUpChannelWidth Integer32, dvmIfUpChannelTxPower TenthdBmV, dvmIfUpChannelSymbolRate Integer32 } dvmIfUpChannelId OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The CMTS identification of the upstream channel." ::= { dvmIfUpstreamChannelEntry 1 } dvmIfUpChannelFrequency OBJECT-TYPE SYNTAX Integer32 (0..1000000000) UNITS "hertz" MAX-ACCESS read-only STATUS current DESCRIPTION "The center of the frequency band associated with this upstream interface. This object returns 0 if the frequency is undefined or unknown. Minimum permitted upstream frequency is 5,000,000 Hz for current technology. See the associated conformance object for write conditions and limitations." ::= { dvmIfUpstreamChannelEntry 2 } dvmIfUpChannelWidth OBJECT-TYPE SYNTAX Integer32 (0..64000000) UNITS "hertz" MAX-ACCESS read-only STATUS current DESCRIPTION "The bandwidth of this upstream interface. This object returns 0 if the interface width is undefined or unknown. Minimum permitted interface width is currently 200,000 Hz. See the associated conformance object for write conditions and limitations." ::= { dvmIfUpstreamChannelEntry 3 } dvmIfUpChannelTxPower OBJECT-TYPE SYNTAX TenthdBmV UNITS "dBmV" MAX-ACCESS read-only STATUS current DESCRIPTION "The operational transmit power for the attached upstream channel at the output of the DVM.E" ::= { dvmIfUpstreamChannelEntry 4 } dvmIfUpChannelSymbolRate OBJECT-TYPE SYNTAX Integer32 (0..1000000000) MAX-ACCESS read-only STATUS current DESCRIPTION "This value indicates the channel rate in kSymbol per second" ::= { dvmIfUpstreamChannelEntry 5 } dvmIfSignalQualityTable OBJECT-TYPE SYNTAX SEQUENCE OF DvmIfSignalQualityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "At the CM, describes the PHY signal quality of downstream channels." ::= { dvmStatus 5 } dvmIfSignalQualityEntry OBJECT-TYPE SYNTAX DvmIfSignalQualityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "At the CM, this object describes the PHY characteristics of a downstream channel." INDEX { ifIndex } ::= { dvmIfSignalQualityTable 1 } DvmIfSignalQualityEntry ::= SEQUENCE { dvmIfSigQUnerroreds Counter32, dvmIfSigQCorrecteds Counter32, dvmIfSigQUncorrectables Counter32, dvmIfSigQSignalNoise TenthdB, dvmIfSigQMicroreflections Integer32 } dvmIfSigQUnerroreds OBJECT-TYPE SYNTAX Counter32 UNITS "codewords" MAX-ACCESS read-only STATUS current DESCRIPTION "Codewords received on this channel without error. This includes all codewords, whether or not they were part of frames destined for this device. Discontinuities in the value of this counter can occur at reinitialization of the managed system." ::= { dvmIfSignalQualityEntry 1 } dvmIfSigQCorrecteds OBJECT-TYPE SYNTAX Counter32 UNITS "codewords" MAX-ACCESS read-only STATUS current DESCRIPTION "Codewords received on this channel with correctable errors. This includes all codewords, whether or not they were part of frames destined for this device. Discontinuities in the value of this counter can occur at reinitialization of the managed system." ::= { dvmIfSignalQualityEntry 2 } dvmIfSigQUncorrectables OBJECT-TYPE SYNTAX Counter32 UNITS "codewords" MAX-ACCESS read-only STATUS current DESCRIPTION "Codewords received on this channel with uncorrectable errors. This includes all codewords, whether or not they were part of frames destined for this device. Discontinuities in the value of this counter can occur at reinitialization of the managed system." ::= { dvmIfSignalQualityEntry 3 } dvmIfSigQSignalNoise OBJECT-TYPE SYNTAX TenthdB UNITS "TenthdB" MAX-ACCESS read-only STATUS current DESCRIPTION "Signal/Noise ratio as perceived for this channel. At the CM, this object describes the Signal/Noise of the downstream channel." ::= { dvmIfSignalQualityEntry 4 } dvmIfSigQMicroreflections OBJECT-TYPE SYNTAX Integer32 (0..255) UNITS "-dBc" MAX-ACCESS read-only STATUS current DESCRIPTION "Microreflections, including in-channel response as perceived on this interface, measured in dBc below the signal level. This object is not assumed to return an absolutely accurate value, but it gives a rough indication of microreflections received on this interface. It is up to the implementer to provide information as accurately as possible." ::= { dvmIfSignalQualityEntry 5 } dvmRxAttenuatorPad OBJECT-TYPE SYNTAX TenthdB UNITS "dB" ACCESS read-only STATUS current DESCRIPTION "The Rx Attenuator pad value. If value is -2,0 the pad sens technology is not connected. Check the wiring inside the DVM If value is -1,0 there is no pad connected. " ::= { dvmStatus 6 } dvmTxAttenuatorPad OBJECT-TYPE SYNTAX TenthdB UNITS "dB" ACCESS read-only STATUS current DESCRIPTION "The Tx Attenuator pad value. If value is -2,0 the pad sens technology is not connected. Check the wiring inside the DVM If value is -1,0 there is no pad connected. " ::= { dvmStatus 7 } dvmRxEqualyzerPlugin OBJECT-TYPE SYNTAX INTEGER { unknown(-2), noEqualyzer(-1), cableSim0ft(0), cableSim75ft(1), cableSim150ft(2), equalyzer4dB(20), equalyzer8dB(21) } ACCESS read-only STATUS current DESCRIPTION "The Equalyzer plugin value. Could be a cable simulator or a equilazer. If value is -2,0 the pad sens technology is not connected. Check the wiring inside the DVM If value is -1,0 there is no pad connected." ::= { dvmStatus 8 } dvmAcInputVoltage OBJECT-TYPE SYNTAX INTEGER ( 0..65535 ) UNITS "1VAC" ACCESS read-only STATUS current DESCRIPTION "Returns the dvm Ac input voltage. Units 1VAC." ::= { dvmStatus 9 } dvmNumberDCPowerSupply OBJECT-TYPE SYNTAX INTEGER ( 0..16 ) ACCESS read-only STATUS current DESCRIPTION "Number of entries in the internal DC power supply table A zero entry means the table does not exist and the functional area is not present in the device." ::= { dvmStatus 10 } dvmTunerHeaterStatus OBJECT-TYPE SYNTAX INTEGER {on(1), off(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "This mib shows the tuner heater block activation status." ::= { dvmStatus 12 } dvmDCPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF DvmDCPowerEntry ACCESS not-accessible STATUS current DESCRIPTION "A table containing information about the Regulated Power." ::= { dvmStatus 11 } dvmDCPowerEntry OBJECT-TYPE SYNTAX DvmDCPowerEntry ACCESS not-accessible STATUS current DESCRIPTION "A list of information about the Regulated Power." INDEX { dvmDCPowerIndex } ::= { dvmDCPowerTable 1 } DvmDCPowerEntry ::= SEQUENCE { dvmDCPowerIndex INTEGER, dvmDCPowerVoltage INTEGER, dvmDCPowerName DisplayString } dvmDCPowerIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS current DESCRIPTION "Index into the dvmDCPowerTable." ::= { dvmDCPowerEntry 1 } dvmDCPowerVoltage OBJECT-TYPE SYNTAX HundredthsVolts UNITS "0.01Vdc" ACCESS read-only STATUS current DESCRIPTION "Returns the regulated power voltage. Units in 0.01 Volts." ::= { dvmDCPowerEntry 2 } dvmDCPowerName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS current DESCRIPTION "Identifies the Physical name of the Power Supply. For example: 3.3V Supply" ::= { dvmDCPowerEntry 3 } END