--***************************************************************************** -- -- Copyright 2014 Electroline Equipment Inc -- All Rights Reserved -- --***************************************************************************** -- Filename: ELECTROLINE-COMMON-TEST.mib -- Author: Alain Leclerc -- Creation Date: 2014.01.14 --***************************************************************************** -- Description: -- -- This file contains the SNMPv2 MIB definition of the test branch -- for the electroline products. -- --***************************************************************************** -- Revision History: -- 2014.01.14 Alain Leclerc First Draft --***************************************************************************** ELECTROLINE-COMMON-TEST-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32 FROM SNMPv2-SMI RowStatus, TruthValue, DateAndTime FROM SNMPv2-TC commonPrivate FROM ELECTROLINE-COMMON-ROOT-MIB DisplayString FROM RFC1213-MIB SnmpAdminString FROM SNMP-FRAMEWORK-MIB; -- RFC 3411; TenthCelsius ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-1" STATUS current DESCRIPTION "This data type represents Temperature that are normally expressed in Celsius. Units are in tenths of a Celsius; for example, 5.1 Celsius will be represented as 51." SYNTAX Integer32 swMode OBJECT-TYPE SYNTAX INTEGER {normal(0), testOnly(1), cmOnly(2), scanFeatureInDiagnosticMode(30)} MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB can be used to control the software activity of the DVM - In Normal mode, the device performs as programmed. - In testOnly mode, the device stops all monitoring activity and populates only the test and calibration MIBS. - In cmOnly mode, the device performs as a plain cable modem. All other features are disabled. The value of this MIB is stored in non-volatile memory. Note that the MODE jumper previously used to access testOnly mode, now is used as an override for the swMode. To have access to set this mode, the brcm factory mib must be enable. Otherwise, read only" ::= { commonPrivate 1 } -- **************************************************************************** -- * Definition of dvmTest Sub-groups -- **************************************************************************** prodTest OBJECT-IDENTITY STATUS current DESCRIPTION "Group of production tests objects related to all models" ::= { commonPrivate 2 } prodInventory OBJECT-IDENTITY STATUS current DESCRIPTION "Group of inventory objects related to all models" ::= { prodTest 1} prodInvHwType OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Hardware Model Identification Number. This information is used by the software to differentiate the hardware platform on which it is running. For example, the HMS022 compatible version and the legacy version of the DHT have different hardware types." ::= { prodInventory 1 } prodInvHwMinorRev OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Hardware Revision Identification Number, representing the PCB version and / or the assembly modification level." ::= { prodInventory 2 } prodInvHwMajorRev OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "This information is used to represent a family of hardware revisions. Major functional changes will trigger a modification of this value" ::= { prodInventory 3 } prodInvHwDrvRev OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "This information is used to track any changes in the manufacturing process not covered by a PCB/Assembly revision and that have an impact on the drivers. " ::= { prodInventory 4 } prodModelNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) ACCESS read-write STATUS current DESCRIPTION "Displays the private electroline model number. Displayed in human-readable format." ::= { prodInventory 5 } --***************************************************************************** -- * MANUFACTURING INVENTORY DATA -- * -- * This section contains additional manufacturing process related information -- * for tracking purposes. --***************************************************************************** prodManufacturingInfo OBJECT-IDENTITY STATUS current DESCRIPTION "Electroline Private sub-tree to access manufacturing information" ::= { prodInventory 10 } prodMfcDateTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-write STATUS current DESCRIPTION "Date and time when this unit was tested (in a string format)." ::= { prodManufacturingInfo 1 } prodMfcTestSwVersion OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Version of the test station on which this unit was tested." ::= { prodManufacturingInfo 2 } prodConfiguration OBJECT-IDENTITY STATUS current DESCRIPTION "Electroline production configuration branch" ::= { prodTest 2} -- **************************************************************************** -- * Definition of Configuration Sub-groups -- **************************************************************************** prodFormatFlash OBJECT-TYPE SYNTAX INTEGER {format(1)} MAX-ACCESS read-write STATUS current DESCRIPTION "This mib triggers the formating of the last blocks of the two flash banks. These section contains the dht logs" ::= {prodConfiguration 1} prodDocsisMode OBJECT-TYPE SYNTAX INTEGER {docsis(1), euroDocsis(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " 1 Set the Dht in DOCSIS mode 2 Set the Dht in EuroDOCSIS mode DEFAULT = 1 " ::= {prodConfiguration 2} ledsControl OBJECT-IDENTITY STATUS current DESCRIPTION "Electroline manufacturing test leds group" ::= { prodTest 3 } ledsControlTable OBJECT-TYPE SYNTAX SEQUENCE OF LedsControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Provides Read/Write access to Leds port." ::= { ledsControl 1 } ledsControlEntry OBJECT-TYPE SYNTAX LedsControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Led Control index and value." INDEX { ledId } ::= { ledsControlTable 1 } LedsControlEntry ::= SEQUENCE { ledId INTEGER, ledState INTEGER, ledDesc OCTET STRING } ledId OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Index into the le led Control value table." ::= { ledsControlEntry 1 } ledState OBJECT-TYPE SYNTAX INTEGER (0..2) MAX-ACCESS read-write STATUS current DESCRIPTION "Control of the LED 0: Unknown state 1: OFF 2: ON Note: Get on this mib always return Unknown state because we cannot know internally what is the state of the led. Note that inverse polarity is taken into account." ::= { ledsControlEntry 2 } ledDesc OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Gives the name of the current PortId" ::= { ledsControlEntry 3 } elineSpectrumAnalyzer OBJECT-IDENTITY STATUS current DESCRIPTION "Test function related to the spectrum analyzer" ::= { commonPrivate 3 } plantPower OBJECT-IDENTITY STATUS current DESCRIPTION "Test group to calculate the total power between 2 frequencies." ::= { elineSpectrumAnalyzer 1 } plantPowerStartFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Fisrt frequency of the span to calculate in Hz " ::= { plantPower 1 } plantPowerStopFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Last frequency of the span to calculate in Hz " ::= { plantPower 2 } plantPowerNbAverage OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Number of FFT to perform and average the result " ::= { plantPower 3 } plantPowerPower OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Return the calculated power in 0.01 dBmV. Important, this function will hang the SNMP agent. Be carrefull! Also, the RBW used will be caluclated to get as near as possible to 2048 bins. That we, we achieve the best possible result within the span specified. You can look at the planPowerRbw and plantPowerNbBins mibs to know the value used. Also, the FFT windows filter use is Hanning. So do not expect to get the best result on analog channels." ::= { plantPower 4 } planPowerRBW OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Return the RBW used to make the last calculation" ::= { plantPower 5 } plantPowerNbBins OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Return the number of bins used to make the last calculation" ::= { plantPower 6 } privateStatus OBJECT-IDENTITY STATUS current DESCRIPTION "Status" ::= { commonPrivate 4 } dieTemperature OBJECT-TYPE SYNTAX TenthCelsius MAX-ACCESS read-only STATUS current DESCRIPTION "Return the die temperature in tenth of Celsius read from the bcm chip internal temperature probe. Note that only the 3383 has this probe." ::= { privateStatus 1 } END