--***************************************************************************** -- -- Copyright 2014 Electroline Equipment Inc -- All Rights Reserved -- -- -- --***************************************************************************** -- Filename: ELECTROLINE-COMMON-CONFIG.mib -- Author: Alain Leclerc -- Creation Date: 2013-01-14 --***************************************************************************** -- Description: -- -- This file contains the SNMPv2 MIB definition of the Configuration branch -- for the electroline products. -- --***************************************************************************** -- Revision History: -- 20013.01.14 Alain Leclerc First Draft --***************************************************************************** ELECTROLINE-COMMON-CONFIG-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32 FROM SNMPv2-SMI RowStatus, TruthValue FROM SNMPv2-TC commonConfiguration FROM ELECTROLINE-COMMON-ROOT-MIB DisplayString FROM RFC1213-MIB NetworkAddress FROM RFC1155-SMI InetAddress, InetAddressType FROM INET-ADDRESS-MIB; -- RFC 4001 -- **************************************************************************** -- * Definition of Configuration Sub-groups -- **************************************************************************** -- **************************************************************************** -- * GLOBAL CONFIGURATION DATA -- * -- * These MIB objects control some functions of the DHT that cannot be set -- * through HMS or DOCSIS MIBs. -- **************************************************************************** cfgResetToFactory OBJECT-TYPE SYNTAX INTEGER {reset(1)} MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB can be used to remotely restore the factory default values, thus overwriting any other setup values (HMS and internal transponder settings) that were stored in the DHT's non-volatile memory. The device must be reset following this command (commonReset or other reset function)." ::= { commonConfiguration 5 } cfgLocalInterfaceMode OBJECT-TYPE SYNTAX INTEGER {disable(0), cpe(1), craft(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB controls the behavior of the local interface port. In craft mode, the USB port (if available on the unit) has a default MAC address which enables a PC to be connected locally to any DHT with the same driver and network adapter settings. In craft mode, read access to the DOCSIS MIBS and read/write access to the HMS is allowed. In CPE mode, the USB/Ethernet port behaves like a normal cable modem USB/Ethernet port, allowing access to the network if this access has been provisioned by the CMTS. In CPE mode, access to the MIBs is as per DOCSIS specifications. As well, read-write access to the Electroline MIBs is permitted. The device must be reset following this command (commonReset or other reset function) in order for the change to take effect. The value of this MIB is stored in non-volatile memory." ::= { commonConfiguration 6 } cfgChannelBondingEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enables or disables the support of channel bonding. The value of this MIB is stored in non-volatile memory." ::= { commonConfiguration 7 } -- **************************************************************************** -- * TIMING RELATED CONFIGURATION DATA -- * -- * This branch of the Electroline MIB allows configuration of certain timings -- * in the DHT's operation -- **************************************************************************** cfgTimers OBJECT-IDENTITY STATUS current DESCRIPTION "Group of configuration objects related to DHT timing " ::= { commonConfiguration 1 } cfgCommonSnmpTimeout OBJECT-TYPE SYNTAX INTEGER (0..10080) MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB controls the SNMP activity watchdog period. The value is in minutes. A value of zero deactivates the feature. When the feature is active, if the DHT does NOT receive any SNMP packets during the period, the DHT will reset. The value of this MIB is stored in non-volatile memory. Default value is 0 (off)" ::= { cfgTimers 1 } -- **************************************************************************** -- * Dual IP RELATED CONFIGURATION -- * -- * This branch of the Electroline MIB should be used to control the IP behavior -- * of the DHT, it controls if the monitoring part of the DHT will be accessible -- * from the DOCSIS SNMP agent or through a separate SNMP agent. -- **************************************************************************** cfgIpInterfaces OBJECT-IDENTITY STATUS current DESCRIPTION "This sections specifies IP behavior for the DHT monitoring interface." ::= { commonConfiguration 2 } cfgIpMode OBJECT-TYPE SYNTAX INTEGER {singleIp(1), dualIp(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "This object controls the IP interface behavior of the DHT Set it to singleIp(1) to access HMS MIB objects through the DOCSIS management interface. Set it to dualIp(2) to instruct the DHT to manage a virtual CPE with a separate IP address and a separate SNMP agent to access the HMS MIBs. The default value for this MIB is singleIp(1). A transponder reset after setting this MIB is necessary in order for the change to take effect. The value of this MIB is stored in non-volatile memory." ::= { cfgIpInterfaces 1 } cfgCommonHmsSnmpAgent OBJECT-IDENTITY STATUS current DESCRIPTION "This sections specifies controls for the agents." ::= { cfgIpInterfaces 50 } cfgCommonHmsSnmpManagerCommunity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB is used to specify the SNMP community string used for write access to the SNMP agent in Dual IP mode. The default value for this MIB is DhtHmsWriteSecret. The value of this MIB is stored in non-volatile memory." ::= { cfgCommonHmsSnmpAgent 1 } cfgCommonHmsSnmpMonitorCommunity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB is used to specify the SNMP Read-only community string used to access the SNMP agent in Dual IP mode. The default value for this MIB is DhtHmsReadSecret. The value of this MIB is stored in non-volatile memory." ::= { cfgCommonHmsSnmpAgent 2 } cfgCommonHmsSnmpAccess OBJECT-IDENTITY STATUS current DESCRIPTION "This sub-tree contains configuration information for HMS SNMP access management." ::= { cfgCommonHmsSnmpAgent 3 } cfgCommonHmsSnmpAccessTable OBJECT-TYPE SYNTAX SEQUENCE OF CfgCommonHmsSnmpAccessEntry MAX-ACCESS read-write STATUS current DESCRIPTION "This table allow access to SNMP objects by network management stations. If the table is empty, access to SNMP objects is unrestricted" ::= { cfgCommonHmsSnmpAccess 1 } cfgCommonHmsSnmpAccessEntry OBJECT-TYPE SYNTAX CfgCommonHmsSnmpAccessEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "HMS SNMP Access entry definition" INDEX { cfgCommonHmsSnmpAccessIndex } ::= { cfgCommonHmsSnmpAccessTable 1 } CfgCommonHmsSnmpAccessEntry ::= SEQUENCE { cfgCommonHmsSnmpAccessIndex INTEGER, cfgCommonHmsSnmpAccessIP IpAddress, cfgCommonHmsSnmpAccessIPMask IpAddress, } cfgCommonHmsSnmpAccessIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Index into the HMS SNMP access table" ::= { cfgCommonHmsSnmpAccessEntry 1 } cfgCommonHmsSnmpAccessIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IPv4 address of the network management station" ::= { cfgCommonHmsSnmpAccessEntry 2 } cfgCommonHmsSnmpAccessIPMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IPv4 subnet mask of the network management station" ::= { cfgCommonHmsSnmpAccessEntry 3 } -- **************************************************************************** -- * GLOBAL CONFIGURATION DATA -- * -- * These MIB objects control some functions of the DHT that cannot be set -- * through HMS or DOCSIS MIBs. -- **************************************************************************** cfgVendorInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) ACCESS read-write STATUS current DESCRIPTION "Vendor-specific information in human-readable format. When set, it mirrors and overrides the mib commonVendorInfo from the SCTE tree." ::= { commonConfiguration 3 } cfgHmsTimeReference OBJECT-TYPE SYNTAX INTEGER {local(1), utc(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "This MIB controls the time reference that is applied in the SCTE HMS tree. It affects how commonTime and alarmLogInformation time reference are represented. Set local(1) to represent these values as the number of seconds since Epoch (00:00:00 UTC, January 1, 1970) adjusted with local time offset. Set utc(2) to represent these values as the number of seconds since Epoch (00:00:00 UTC, January 1, 1970)." ::= { commonConfiguration 4 } END