DigiPower-PDU-MIB DEFINITIONS ::= BEGIN IMPORTS TRAP-TYPE FROM RFC-1215 DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 enterprises FROM RFC1155-SMI; digipower OBJECT IDENTIFIER ::= { enterprises 17420 } products OBJECT IDENTIFIER ::= { digipower 1 } devTable OBJECT IDENTIFIER ::= { products 2 } envthreshold OBJECT IDENTIFIER ::= { products 4 } -- DEV basic information -- devID OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION "The ID number of dev." ::= { devTable 1 } devIP OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current IP address, netmask, default gateway, and DNS server." ::= { devTable 2 } devMAC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate current MAC address." ::= { devTable 3 } devVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate current firmware version." ::= { devTable 4 } devInfo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the count of attached PDUs and their id." ::= { devTable 5 } devValues OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the PDU values (currents) from PDU1 to PDU16" ::= { devTable 6 } devTemperature OBJECT-TYPE SYNTAX INTEGER (-50..100) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the PDU temperature in Celsius degree" ::= { devTable 7 } devHumidity OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the PDU humidity in percentage (%)" ::= { devTable 8 } pduTable OBJECT IDENTIFIER ::= { devTable 9 } -- PDU entries -- -- PDU01 -- pdu01Entry OBJECT IDENTIFIER ::= { pduTable 1 } pdu01Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the current of PDU-01 detect." ::= { pdu01Entry 11 } pdu01SubValues OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the outlet values (currents) from Outlet1 to Outlet8" ::= { pdu01Entry 12 } pdu01OutletStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 1: Outlet ON 0: Outlet OFF -1: Outlet is not available -2: Outlet powr lost or Breaker triggered" ::= { pdu01Entry 13 } pdu01OutletConfigs OBJECT IDENTIFIER ::= { pdu01Entry 14 } pdu01Outlet1Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet1" ::= { pdu01OutletConfigs 1 } pdu01Outlet2Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet2" ::= { pdu01OutletConfigs 2 } pdu01Outlet3Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet3" ::= { pdu01OutletConfigs 3 } pdu01Outlet4Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet4" ::= { pdu01OutletConfigs 4 } pdu01Outlet5Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet5" ::= { pdu01OutletConfigs 5 } pdu01Outlet6Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet6" ::= { pdu01OutletConfigs 6 } pdu01Outlet7Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet7" ::= { pdu01OutletConfigs 7 } pdu01Outlet8Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet8" ::= { pdu01OutletConfigs 8 } pdu01Outlet9Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet9" ::= { pdu01OutletConfigs 9 } pdu01Outlet10Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet10" ::= { pdu01OutletConfigs 10 } pdu01Outlet11Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet11" ::= { pdu01OutletConfigs 11 } pdu01Outlet12Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet12" ::= { pdu01OutletConfigs 12 } pdu01Outlet13Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet13" ::= { pdu01OutletConfigs 13 } pdu01Outlet14Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet14" ::= { pdu01OutletConfigs 14 } pdu01Outlet15Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet15" ::= { pdu01OutletConfigs 15 } pdu01Outlet16Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet16" ::= { pdu01OutletConfigs 16 } pdu01Outlet17Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet17" ::= { pdu01OutletConfigs 17 } pdu01Outlet18Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet18" ::= { pdu01OutletConfigs 18 } pdu01Outlet19Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet19" ::= { pdu01OutletConfigs 19 } pdu01Outlet20Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet20" ::= { pdu01OutletConfigs 20 } pdu01Outlet21Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet21" ::= { pdu01OutletConfigs 21 } pdu01Outlet22Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet22" ::= { pdu01OutletConfigs 22 } pdu01Outlet23Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet23" ::= { pdu01OutletConfigs 23 } pdu01Outlet24Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet24" ::= { pdu01OutletConfigs 24 } pdu01Threshold1 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 1 (warning current)." ::= { pdu01Entry 15 } pdu01Threshold2 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 2 (critical current)." ::= { pdu01Entry 16 } pdu01Voltage OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate voltage of PDU." ::= { pdu01Entry 17 } pdu01ModelName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model name." ::= { pdu01Entry 18 } pdu01ModelNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model number." ::= { pdu01Entry 19 } pdu01Identify OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU identify." ::= { pdu01Entry 20 } pdu01DelayOn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet On delay time. Unit is second " ::= { pdu01Entry 21 } pdu01DelayOff OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet Off delay time. Unit is second " ::= { pdu01Entry 22 } -- PDU02 -- pdu02Entry OBJECT IDENTIFIER ::= { pduTable 2 } pdu02Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the current of PDU-02 detect." ::= { pdu02Entry 11 } pdu02SubValues OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the outlet values (currents) from Outlet1 to Outlet8" ::= { pdu02Entry 12 } pdu02OutletStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 1: Outlet ON 0: Outlet OFF -1: Outlet is not available -2: Outlet powr lost or Breaker triggered" ::= { pdu02Entry 13 } pdu02OutletConfigs OBJECT IDENTIFIER ::= { pdu02Entry 14 } pdu02Outlet1Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet1" ::= { pdu02OutletConfigs 1 } pdu02Outlet2Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet2" ::= { pdu02OutletConfigs 2 } pdu02Outlet3Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet3" ::= { pdu02OutletConfigs 3 } pdu02Outlet4Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet4" ::= { pdu02OutletConfigs 4 } pdu02Outlet5Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet5" ::= { pdu02OutletConfigs 5 } pdu02Outlet6Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet6" ::= { pdu02OutletConfigs 6 } pdu02Outlet7Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet7" ::= { pdu02OutletConfigs 7 } pdu02Outlet8Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet8" ::= { pdu02OutletConfigs 8 } pdu02Threshold1 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 1 (warning current)." ::= { pdu02Entry 15 } pdu02Threshold2 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 2 (critical current)." ::= { pdu02Entry 16 } pdu02Voltage OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate voltage of PDU." ::= { pdu02Entry 17 } pdu02ModelName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model name." ::= { pdu02Entry 18 } pdu02ModelNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model number." ::= { pdu02Entry 19 } pdu02Identify OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU identify." ::= { pdu02Entry 20 } pdu02DelayOn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet On delay time. Unit is second " ::= { pdu02Entry 21 } pdu02DelayOff OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet Off delay time. Unit is second " ::= { pdu02Entry 22 } -- PDU03 -- pdu03Entry OBJECT IDENTIFIER ::= { pduTable 3 } pdu03Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the current of PDU-03 detect." ::= { pdu03Entry 11 } pdu03SubValues OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the outlet values (currents) from Outlet1 to Outlet8" ::= { pdu03Entry 12 } pdu03OutletStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 1: Outlet ON 0: Outlet OFF -1: Outlet is not available -2: Outlet powr lost or Breaker triggered" ::= { pdu03Entry 13 } pdu03OutletConfigs OBJECT IDENTIFIER ::= { pdu03Entry 14 } pdu03Outlet1Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet1" ::= { pdu03OutletConfigs 1 } pdu03Outlet2Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet2" ::= { pdu03OutletConfigs 2 } pdu03Outlet3Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet3" ::= { pdu03OutletConfigs 3 } pdu03Outlet4Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet4" ::= { pdu03OutletConfigs 4 } pdu03Outlet5Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet5" ::= { pdu03OutletConfigs 5 } pdu03Outlet6Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet6" ::= { pdu03OutletConfigs 6 } pdu03Outlet7Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet7" ::= { pdu03OutletConfigs 7 } pdu03Outlet8Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet8" ::= { pdu03OutletConfigs 8 } pdu03Threshold1 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 1 (warning current)." ::= { pdu03Entry 15 } pdu03Threshold2 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 2 (critical current)." ::= { pdu03Entry 16 } pdu03Voltage OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate voltage of PDU." ::= { pdu03Entry 17 } pdu03ModelName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model name." ::= { pdu03Entry 18 } pdu03ModelNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model number." ::= { pdu03Entry 19 } pdu03Identify OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU identify." ::= { pdu03Entry 20 } pdu03DelayOn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet On delay time. Unit is second " ::= { pdu03Entry 21 } pdu03DelayOff OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet Off delay time. Unit is second " ::= { pdu03Entry 22 } -- PDU04 -- pdu04Entry OBJECT IDENTIFIER ::= { pduTable 4 } pdu04Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the current of PDU-04 detect." ::= { pdu04Entry 11 } pdu04SubValues OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the outlet values (currents) from Outlet1 to Outlet8" ::= { pdu04Entry 12 } pdu04OutletStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 1: Outlet ON 0: Outlet OFF -1: Outlet is not available -2: Outlet powr lost or Breaker triggered" ::= { pdu04Entry 13 } pdu04OutletConfigs OBJECT IDENTIFIER ::= { pdu04Entry 14 } pdu04Outlet1Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet1" ::= { pdu04OutletConfigs 1 } pdu04Outlet2Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet2" ::= { pdu04OutletConfigs 2 } pdu04Outlet3Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet3" ::= { pdu04OutletConfigs 3 } pdu04Outlet4Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet4" ::= { pdu04OutletConfigs 4 } pdu04Outlet5Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet5" ::= { pdu04OutletConfigs 5 } pdu04Outlet6Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet6" ::= { pdu04OutletConfigs 6 } pdu04Outlet7Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet7" ::= { pdu04OutletConfigs 7 } pdu04Outlet8Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet8" ::= { pdu04OutletConfigs 8 } pdu04Threshold1 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 1 (warning current)." ::= { pdu04Entry 15 } pdu04Threshold2 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 2 (critical current)." ::= { pdu04Entry 16 } pdu04Voltage OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate voltage of PDU." ::= { pdu04Entry 17 } pdu04ModelName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model name." ::= { pdu04Entry 18 } pdu04ModelNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model number." ::= { pdu04Entry 19 } pdu04Identify OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU identify." ::= { pdu04Entry 20 } pdu04DelayOn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet On delay time. Unit is second " ::= { pdu04Entry 21 } pdu04DelayOff OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet Off delay time. Unit is second " ::= { pdu04Entry 22 } -- PDU05 -- pdu05Entry OBJECT IDENTIFIER ::= { pduTable 5 } pdu05Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the current of PDU-05 detect." ::= { pdu05Entry 11 } pdu05SubValues OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the outlet values (currents) from Outlet1 to Outlet8" ::= { pdu05Entry 12 } pdu05OutletStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 1: Outlet ON 0: Outlet OFF -1: Outlet is not available -2: Outlet powr lost or Breaker triggered" ::= { pdu05Entry 13 } pdu05OutletConfigs OBJECT IDENTIFIER ::= { pdu05Entry 14 } pdu05Outlet1Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet1" ::= { pdu05OutletConfigs 1 } pdu05Outlet2Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet2" ::= { pdu05OutletConfigs 2 } pdu05Outlet3Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet3" ::= { pdu05OutletConfigs 3 } pdu05Outlet4Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet4" ::= { pdu05OutletConfigs 4 } pdu05Outlet5Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet5" ::= { pdu05OutletConfigs 5 } pdu05Outlet6Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet6" ::= { pdu05OutletConfigs 6 } pdu05Outlet7Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet7" ::= { pdu05OutletConfigs 7 } pdu05Outlet8Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet8" ::= { pdu05OutletConfigs 8 } pdu05Threshold1 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 1 (warning current)." ::= { pdu05Entry 15 } pdu05Threshold2 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 2 (critical current)." ::= { pdu05Entry 16 } pdu05Voltage OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate voltage of PDU." ::= { pdu05Entry 17 } pdu05ModelName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model name." ::= { pdu05Entry 18 } pdu05ModelNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model number." ::= { pdu05Entry 19 } pdu05Identify OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU identify." ::= { pdu05Entry 20 } pdu05DelayOn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet On delay time. Unit is second " ::= { pdu05Entry 21 } pdu05DelayOff OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet Off delay time. Unit is second " ::= { pdu05Entry 22 } -- PDU06 -- pdu06Entry OBJECT IDENTIFIER ::= { pduTable 6 } pdu06Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the current of PDU-06 detect." ::= { pdu06Entry 11 } pdu06SubValues OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the outlet values (currents) from Outlet1 to Outlet8" ::= { pdu06Entry 12 } pdu06OutletStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 1: Outlet ON 0: Outlet OFF -1: Outlet is not available -2: Outlet powr lost or Breaker triggered" ::= { pdu06Entry 13 } pdu06OutletConfigs OBJECT IDENTIFIER ::= { pdu06Entry 14 } pdu06Outlet1Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet1" ::= { pdu06OutletConfigs 1 } pdu06Outlet2Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet2" ::= { pdu06OutletConfigs 2 } pdu06Outlet3Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet3" ::= { pdu06OutletConfigs 3 } pdu06Outlet4Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet4" ::= { pdu06OutletConfigs 4 } pdu06Outlet5Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet5" ::= { pdu06OutletConfigs 5 } pdu06Outlet6Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet6" ::= { pdu06OutletConfigs 6 } pdu06Outlet7Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet7" ::= { pdu06OutletConfigs 7 } pdu06Outlet8Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet8" ::= { pdu06OutletConfigs 8 } pdu06Threshold1 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 1 (warning current)." ::= { pdu06Entry 15 } pdu06Threshold2 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 2 (critical current)." ::= { pdu06Entry 16 } pdu06Voltage OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate voltage of PDU." ::= { pdu06Entry 17 } pdu06ModelName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model name." ::= { pdu06Entry 18 } pdu06ModelNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model number." ::= { pdu06Entry 19 } pdu06Identify OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU identify." ::= { pdu06Entry 20 } pdu06DelayOn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet On delay time. Unit is second " ::= { pdu06Entry 21 } pdu06DelayOff OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet Off delay time. Unit is second " ::= { pdu06Entry 22 } -- PDU07 -- pdu07Entry OBJECT IDENTIFIER ::= { pduTable 7 } pdu07Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the current of PDU-07 detect." ::= { pdu07Entry 11 } pdu07SubValues OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the outlet values (currents) from Outlet1 to Outlet8" ::= { pdu07Entry 12 } pdu07OutletStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 1: Outlet ON 0: Outlet OFF -1: Outlet is not available -2: Outlet powr lost or Breaker triggered" ::= { pdu07Entry 13 } pdu07OutletConfigs OBJECT IDENTIFIER ::= { pdu07Entry 14 } pdu07Outlet1Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet1" ::= { pdu07OutletConfigs 1 } pdu07Outlet2Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet2" ::= { pdu07OutletConfigs 2 } pdu07Outlet3Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet3" ::= { pdu07OutletConfigs 3 } pdu07Outlet4Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet4" ::= { pdu07OutletConfigs 4 } pdu07Outlet5Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet5" ::= { pdu07OutletConfigs 5 } pdu07Outlet6Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet6" ::= { pdu07OutletConfigs 6 } pdu07Outlet7Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet7" ::= { pdu07OutletConfigs 7 } pdu07Outlet8Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet8" ::= { pdu07OutletConfigs 8 } pdu07Threshold1 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 1 (warning current)." ::= { pdu07Entry 15 } pdu07Threshold2 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 2 (critical current)." ::= { pdu07Entry 16 } pdu07Voltage OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate voltage of PDU." ::= { pdu07Entry 17 } pdu07ModelName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model name." ::= { pdu07Entry 18 } pdu07ModelNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model number." ::= { pdu07Entry 19 } pdu07Identify OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU identify." ::= { pdu07Entry 20 } pdu07DelayOn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet On delay time. Unit is second " ::= { pdu07Entry 21 } pdu07DelayOff OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet Off delay time. Unit is second " ::= { pdu07Entry 22 } -- PDU08 -- pdu08Entry OBJECT IDENTIFIER ::= { pduTable 8 } pdu08Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the current of PDU-08 detect." ::= { pdu08Entry 11 } pdu08SubValues OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the outlet values (currents) from Outlet1 to Outlet8" ::= { pdu08Entry 12 } pdu08OutletStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 1: Outlet ON 0: Outlet OFF -1: Outlet is not available -2: Outlet powr lost or Breaker triggered" ::= { pdu08Entry 13 } pdu08OutletConfigs OBJECT IDENTIFIER ::= { pdu08Entry 14 } pdu08Outlet1Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet1" ::= { pdu08OutletConfigs 1 } pdu08Outlet2Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet2" ::= { pdu08OutletConfigs 2 } pdu08Outlet3Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet3" ::= { pdu08OutletConfigs 3 } pdu08Outlet4Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet4" ::= { pdu08OutletConfigs 4 } pdu08Outlet5Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet5" ::= { pdu08OutletConfigs 5 } pdu08Outlet6Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet6" ::= { pdu08OutletConfigs 6 } pdu08Outlet7Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet7" ::= { pdu08OutletConfigs 7 } pdu08Outlet8Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet8" ::= { pdu08OutletConfigs 8 } pdu08Threshold1 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 1 (warning current)." ::= { pdu08Entry 15 } pdu08Threshold2 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 2 (critical current)." ::= { pdu08Entry 16 } pdu08Voltage OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate voltage of PDU." ::= { pdu08Entry 17 } pdu08ModelName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model name." ::= { pdu08Entry 18 } pdu08ModelNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model number." ::= { pdu08Entry 19 } pdu08Identify OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU identify." ::= { pdu08Entry 20 } pdu08DelayOn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet On delay time. Unit is second " ::= { pdu08Entry 21 } pdu08DelayOff OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet Off delay time. Unit is second " ::= { pdu08Entry 22 } -- PDU09 -- pdu09Entry OBJECT IDENTIFIER ::= { pduTable 9 } pdu09Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the current of PDU-09 detect." ::= { pdu09Entry 11 } pdu09SubValues OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the outlet values (currents) from Outlet1 to Outlet8" ::= { pdu09Entry 12 } pdu09OutletStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 1: Outlet ON 0: Outlet OFF -1: Outlet is not available -2: Outlet powr lost or Breaker triggered" ::= { pdu09Entry 13 } pdu09OutletConfigs OBJECT IDENTIFIER ::= { pdu09Entry 14 } pdu09Outlet1Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet1" ::= { pdu09OutletConfigs 1 } pdu09Outlet2Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet2" ::= { pdu09OutletConfigs 2 } pdu09Outlet3Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet3" ::= { pdu09OutletConfigs 3 } pdu09Outlet4Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet4" ::= { pdu09OutletConfigs 4 } pdu09Outlet5Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet5" ::= { pdu09OutletConfigs 5 } pdu09Outlet6Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet6" ::= { pdu09OutletConfigs 6 } pdu09Outlet7Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet7" ::= { pdu09OutletConfigs 7 } pdu09Outlet8Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet8" ::= { pdu09OutletConfigs 8 } pdu09Threshold1 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 1 (warning current)." ::= { pdu09Entry 15 } pdu09Threshold2 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 2 (critical current)." ::= { pdu09Entry 16 } pdu09Voltage OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate voltage of PDU." ::= { pdu09Entry 17 } pdu09ModelName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model name." ::= { pdu09Entry 18 } pdu09ModelNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model number." ::= { pdu09Entry 19 } pdu09Identify OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU identify." ::= { pdu09Entry 20 } pdu09DelayOn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet On delay time. Unit is second " ::= { pdu09Entry 21 } pdu09DelayOff OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet Off delay time. Unit is second " ::= { pdu09Entry 22 } -- PDU10 -- pdu10Entry OBJECT IDENTIFIER ::= { pduTable 10 } pdu10Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the current of PDU-10 detect." ::= { pdu10Entry 11 } pdu10SubValues OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the outlet values (currents) from Outlet1 to Outlet8" ::= { pdu10Entry 12 } pdu10OutletStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 1: Outlet ON 0: Outlet OFF -1: Outlet is not available -2: Outlet powr lost or Breaker triggered" ::= { pdu10Entry 13 } pdu10OutletConfigs OBJECT IDENTIFIER ::= { pdu10Entry 14 } pdu10Outlet1Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet1" ::= { pdu10OutletConfigs 1 } pdu10Outlet2Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet2" ::= { pdu10OutletConfigs 2 } pdu10Outlet3Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet3" ::= { pdu10OutletConfigs 3 } pdu10Outlet4Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet4" ::= { pdu10OutletConfigs 4 } pdu10Outlet5Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet5" ::= { pdu10OutletConfigs 5 } pdu10Outlet6Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet6" ::= { pdu10OutletConfigs 6 } pdu10Outlet7Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet7" ::= { pdu10OutletConfigs 7 } pdu10Outlet8Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet8" ::= { pdu10OutletConfigs 8 } pdu10Threshold1 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 1 (warning current)." ::= { pdu10Entry 15 } pdu10Threshold2 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 2 (critical current)." ::= { pdu10Entry 16 } pdu10Voltage OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate voltage of PDU." ::= { pdu10Entry 17 } pdu10ModelName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model name." ::= { pdu10Entry 18 } pdu10ModelNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model number." ::= { pdu10Entry 19 } pdu10Identify OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU identify." ::= { pdu10Entry 20 } pdu10DelayOn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet On delay time. Unit is second " ::= { pdu10Entry 21 } pdu10DelayOff OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet Off delay time. Unit is second " ::= { pdu10Entry 22 } -- PDU11 -- pdu11Entry OBJECT IDENTIFIER ::= { pduTable 11 } pdu11Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the current of PDU-11 detect." ::= { pdu11Entry 11 } pdu11SubValues OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the outlet values (currents) from Outlet1 to Outlet8" ::= { pdu11Entry 12 } pdu11OutletStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 1: Outlet ON 0: Outlet OFF -1: Outlet is not available -2: Outlet powr lost or Breaker triggered" ::= { pdu11Entry 13 } pdu11OutletConfigs OBJECT IDENTIFIER ::= { pdu11Entry 14 } pdu11Outlet1Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet1" ::= { pdu11OutletConfigs 1 } pdu11Outlet2Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet2" ::= { pdu11OutletConfigs 2 } pdu11Outlet3Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet3" ::= { pdu11OutletConfigs 3 } pdu11Outlet4Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet4" ::= { pdu11OutletConfigs 4 } pdu11Outlet5Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet5" ::= { pdu11OutletConfigs 5 } pdu11Outlet6Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet6" ::= { pdu11OutletConfigs 6 } pdu11Outlet7Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet7" ::= { pdu11OutletConfigs 7 } pdu11Outlet8Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet8" ::= { pdu11OutletConfigs 8 } pdu11Threshold1 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 1 (warning current)." ::= { pdu11Entry 15 } pdu11Threshold2 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 2 (critical current)." ::= { pdu11Entry 16 } pdu11Voltage OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate voltage of PDU." ::= { pdu11Entry 17 } pdu11ModelName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model name." ::= { pdu11Entry 18 } pdu11ModelNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model number." ::= { pdu11Entry 19 } pdu11Identify OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU identify." ::= { pdu11Entry 20 } pdu11DelayOn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet On delay time. Unit is second " ::= { pdu11Entry 21 } pdu11DelayOff OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet Off delay time. Unit is second " ::= { pdu11Entry 22 } -- PDU12 -- pdu12Entry OBJECT IDENTIFIER ::= { pduTable 12 } pdu12Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the current of PDU-12 detect." ::= { pdu12Entry 11 } pdu12SubValues OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the outlet values (currents) from Outlet1 to Outlet8" ::= { pdu12Entry 12 } pdu12OutletStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 1: Outlet ON 0: Outlet OFF -1: Outlet is not available -2: Outlet powr lost or Breaker triggered" ::= { pdu12Entry 13 } pdu12OutletConfigs OBJECT IDENTIFIER ::= { pdu12Entry 14 } pdu12Outlet1Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet1" ::= { pdu12OutletConfigs 1 } pdu12Outlet2Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet2" ::= { pdu12OutletConfigs 2 } pdu12Outlet3Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet3" ::= { pdu12OutletConfigs 3 } pdu12Outlet4Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet4" ::= { pdu12OutletConfigs 4 } pdu12Outlet5Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet5" ::= { pdu12OutletConfigs 5 } pdu12Outlet6Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet6" ::= { pdu12OutletConfigs 6 } pdu12Outlet7Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet7" ::= { pdu12OutletConfigs 7 } pdu12Outlet8Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet8" ::= { pdu12OutletConfigs 8 } pdu12Threshold1 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 1 (warning current)." ::= { pdu12Entry 15 } pdu12Threshold2 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 2 (critical current)." ::= { pdu12Entry 16 } pdu12Voltage OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate voltage of PDU." ::= { pdu12Entry 17 } pdu12ModelName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model name." ::= { pdu12Entry 18 } pdu12ModelNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model number." ::= { pdu12Entry 19 } pdu12Identify OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU identify." ::= { pdu12Entry 20 } pdu12DelayOn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet On delay time. Unit is second " ::= { pdu12Entry 21 } pdu12DelayOff OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet Off delay time. Unit is second " ::= { pdu12Entry 22 } -- PDU13 -- pdu13Entry OBJECT IDENTIFIER ::= { pduTable 13 } pdu13Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the current of PDU-13 detect." ::= { pdu13Entry 11 } pdu13SubValues OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the outlet values (currents) from Outlet1 to Outlet8" ::= { pdu13Entry 12 } pdu13OutletStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 1: Outlet ON 0: Outlet OFF -1: Outlet is not available -2: Outlet powr lost or Breaker triggered" ::= { pdu13Entry 13 } pdu13OutletConfigs OBJECT IDENTIFIER ::= { pdu13Entry 14 } pdu13Outlet1Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet1" ::= { pdu13OutletConfigs 1 } pdu13Outlet2Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet2" ::= { pdu13OutletConfigs 2 } pdu13Outlet3Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet3" ::= { pdu13OutletConfigs 3 } pdu13Outlet4Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet4" ::= { pdu13OutletConfigs 4 } pdu13Outlet5Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet5" ::= { pdu13OutletConfigs 5 } pdu13Outlet6Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet6" ::= { pdu13OutletConfigs 6 } pdu13Outlet7Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet7" ::= { pdu13OutletConfigs 7 } pdu13Outlet8Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet8" ::= { pdu13OutletConfigs 8 } pdu13Threshold1 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 1 (warning current)." ::= { pdu13Entry 15 } pdu13Threshold2 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 2 (critical current)." ::= { pdu13Entry 16 } pdu13Voltage OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate voltage of PDU." ::= { pdu13Entry 17 } pdu13ModelName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model name." ::= { pdu13Entry 18 } pdu13ModelNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model number." ::= { pdu13Entry 19 } pdu13Identify OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU identify." ::= { pdu13Entry 20 } pdu13DelayOn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet On delay time. Unit is second " ::= { pdu13Entry 21 } pdu13DelayOff OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet Off delay time. Unit is second " ::= { pdu13Entry 22 } -- PDU14 -- pdu14Entry OBJECT IDENTIFIER ::= { pduTable 14 } pdu14Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the current of PDU-14 detect." ::= { pdu14Entry 11 } pdu14SubValues OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the outlet values (currents) from Outlet1 to Outlet8" ::= { pdu14Entry 12 } pdu14OutletStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 1: Outlet ON 0: Outlet OFF -1: Outlet is not available -2: Outlet powr lost or Breaker triggered" ::= { pdu14Entry 13 } pdu14OutletConfigs OBJECT IDENTIFIER ::= { pdu14Entry 14 } pdu14Outlet1Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet1" ::= { pdu14OutletConfigs 1 } pdu14Outlet2Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet2" ::= { pdu14OutletConfigs 2 } pdu14Outlet3Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet3" ::= { pdu14OutletConfigs 3 } pdu14Outlet4Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet4" ::= { pdu14OutletConfigs 4 } pdu14Outlet5Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet5" ::= { pdu14OutletConfigs 5 } pdu14Outlet6Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet6" ::= { pdu14OutletConfigs 6 } pdu14Outlet7Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet7" ::= { pdu14OutletConfigs 7 } pdu14Outlet8Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet8" ::= { pdu14OutletConfigs 8 } pdu14Threshold1 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 1 (warning current)." ::= { pdu14Entry 15 } pdu14Threshold2 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 2 (critical current)." ::= { pdu14Entry 16 } pdu14Voltage OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate voltage of PDU." ::= { pdu14Entry 17 } pdu14ModelName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model name." ::= { pdu14Entry 18 } pdu14ModelNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model number." ::= { pdu14Entry 19 } pdu14Identify OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU identify." ::= { pdu14Entry 20 } pdu14DelayOn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet On delay time. Unit is second " ::= { pdu14Entry 21 } pdu14DelayOff OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet Off delay time. Unit is second " ::= { pdu14Entry 22 } -- PDU15 -- pdu15Entry OBJECT IDENTIFIER ::= { pduTable 15 } pdu15Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the current of PDU-15 detect." ::= { pdu15Entry 11 } pdu15SubValues OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the outlet values (currents) from Outlet1 to Outlet8" ::= { pdu15Entry 12 } pdu15OutletStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 1: Outlet ON 0: Outlet OFF -1: Outlet is not available -2: Outlet powr lost or Breaker triggered" ::= { pdu15Entry 13 } pdu15OutletConfigs OBJECT IDENTIFIER ::= { pdu15Entry 14 } pdu15Outlet1Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet1" ::= { pdu15OutletConfigs 1 } pdu15Outlet2Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet2" ::= { pdu15OutletConfigs 2 } pdu15Outlet3Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet3" ::= { pdu15OutletConfigs 3 } pdu15Outlet4Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet4" ::= { pdu15OutletConfigs 4 } pdu15Outlet5Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet5" ::= { pdu15OutletConfigs 5 } pdu15Outlet6Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet6" ::= { pdu15OutletConfigs 6 } pdu15Outlet7Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet7" ::= { pdu15OutletConfigs 7 } pdu15Outlet8Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet8" ::= { pdu15OutletConfigs 8 } pdu15Threshold1 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 1 (warning current)." ::= { pdu15Entry 15 } pdu15Threshold2 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 2 (critical current)." ::= { pdu15Entry 16 } pdu15Voltage OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate voltage of PDU." ::= { pdu15Entry 17 } pdu15ModelName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model name." ::= { pdu15Entry 18 } pdu15ModelNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model number." ::= { pdu15Entry 19 } pdu15Identify OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU identify." ::= { pdu15Entry 20 } pdu15DelayOn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet On delay time. Unit is second " ::= { pdu15Entry 21 } pdu15DelayOff OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet Off delay time. Unit is second " ::= { pdu15Entry 22 } -- PDU16 -- pdu16Entry OBJECT IDENTIFIER ::= { pduTable 16 } pdu16Value OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the current of PDU-16 detect." ::= { pdu16Entry 11 } pdu16SubValues OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the outlet values (currents) from Outlet1 to Outlet8" ::= { pdu16Entry 12 } pdu16OutletStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8 1: Outlet ON 0: Outlet OFF -1: Outlet is not available -2: Outlet powr lost or Breaker triggered" ::= { pdu16Entry 13 } pdu16OutletConfigs OBJECT IDENTIFIER ::= { pdu16Entry 14 } pdu16Outlet1Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet1" ::= { pdu16OutletConfigs 1 } pdu16Outlet2Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet2" ::= { pdu16OutletConfigs 2 } pdu16Outlet3Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet3" ::= { pdu16OutletConfigs 3 } pdu16Outlet4Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet4" ::= { pdu16OutletConfigs 4 } pdu16Outlet5Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet5" ::= { pdu16OutletConfigs 5 } pdu16Outlet6Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet6" ::= { pdu16OutletConfigs 6 } pdu16Outlet7Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet7" ::= { pdu16OutletConfigs 7 } pdu16Outlet8Config OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate the configuration of Outlet8" ::= { pdu16OutletConfigs 8 } pdu16Threshold1 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 1 (warning current)." ::= { pdu16Entry 15 } pdu16Threshold2 OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate current threshold 2 (critical current)." ::= { pdu16Entry 16 } pdu16Voltage OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate voltage of PDU." ::= { pdu16Entry 17 } pdu16ModelName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model name." ::= { pdu16Entry 18 } pdu16ModelNo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate PDU model number." ::= { pdu16Entry 19 } pdu16Identify OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU identify." ::= { pdu16Entry 20 } pdu16DelayOn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet On delay time. Unit is second " ::= { pdu16Entry 21 } pdu16DelayOff OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate PDU Outlet Off delay time. Unit is second " ::= { pdu16Entry 22 } -- ENV Threshold information -- tempLower OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate temperature lower threshold" ::= { envthreshold 42 } tempUpper OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate temperature upper threshold" ::= { envthreshold 43 } humidityLower OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate humidity lower threshold" ::= { envthreshold 44 } humidityLower OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-write STATUS mandatory DESCRIPTION "Indicate humidity upper threshold" ::= { envthreshold 45 } --dev traps ---------------------------------------------------------------- --pdu01TrapEntry TRAP-TYPE -- ENTERPRISE digipower -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION -- "An entry containing trap information of PDU-01." -- ::= 1 --pdu01CommunicationLost TRAP-TYPE -- SYNTAX pdu01CommunicationLost -- DESCRIPTION -- "PDU-01 communication lost." -- :: = { pdu01TrapEntry 19 } devOutOfThreshold1 TRAP-TYPE ENTERPRISE digipower DESCRIPTION "WARNING: DEV current out of threshold 1." ::= 105 devOutOfThreshold2 TRAP-TYPE ENTERPRISE digipower DESCRIPTION "CRITICAL: DEV current out of threshold 2." ::= 106 --devCommunicationLost TRAP-TYPE -- ENTERPRISE digipower -- DESCRIPTION -- "CRITICAL: DEV Communication lost." -- ::= 107 devBackToNormal TRAP-TYPE ENTERPRISE digipower DESCRIPTION "NORMAL: DEV back to normal states" ::= 108 END