Dell-LAN-TRAP-MIB DEFINITIONS ::= BEGIN -- Broadcom FastPath Radius Authentication Client MIB -- Copyright 2016-2022 Broadcom. -- This SNMP Management Information Specification -- embodies Broadcom's confidential and proprietary -- intellectual property. Broadcom retains all title -- and ownership in the Specification including any revisions. -- This Specification is supplied "AS IS", Broadcom -- makes no warranty, either expressed or implied, -- as to the use, operation, condition, or performance of the -- Specification. IMPORTS OBJECT-TYPE, NOTIFICATION-TYPE FROM SNMPv2-SMI DisplayString, DateAndTime FROM SNMPv2-TC dellLan, dellLanCommon FROM Dell-Vendor-MIB; -- Dell alarms specific global parameters are defined in this group. dellAlarmGroup MODULE-IDENTITY LAST-UPDATED "200504260000Z" -- 26 Apr 2005 12:00:00 GMT ORGANIZATION "Dell." CONTACT-INFO " " DESCRIPTION " " ::= { dellLanCommon 1 } -- dellAlarmGroup OBJECT IDENTIFIER ::= { dellLanCommon 1 } ---------------------------------------------- -- Variable binding list parameters for traps: ---------------------------------------------- dellTrapInfo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This text string may be used to provide additional information regarding the trap being sent. Any specific formatting information is given in the trap definition." ::= { dellAlarmGroup 1 } dellTrapSeverity OBJECT-TYPE SYNTAX INTEGER { clear(0), info(1), minor(2), major(3), critical(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The severity type of the enterprise-specific trap sent to the Network Management Station by the Dell managed device. The Severity level are defined as follows: Critical - service affecting event. Major - a major error which is not service affecting but does require immediate user attention to prevent further degredation of the system, which may lead to a critical error. For example, if a redundant port failure would be considered a major event whereas the failure of an unprotected port is a critical event. Minor - a minor event which is not service affecting and is unlikely to lead to a major or critical event. The user does not need to take immediate actions but some action is required to clear the event. Info - a notification to the user of some event that does not require any user action. For example, a security notification is useful information but does not require the user to take any specific immediate action. This event is not cleared. Clear - this special trap is sent to clear some previously sent trap. Note that if the sequence number sent with the clear event is 0 then the clear event is used to indicate that all outstanding event of this particular type on a given source (dellTrapSource) has been cleared. If the event sequence number (dellTrapSeqNum) is sent with a non-zero value, then the clear event is sent to clear only the specific trap instance designated by the sequence number in question." ::= { dellAlarmGroup 2 } dellTrapSource OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The trap source is a string identifying the component of the device generating the trap. The source identifies the component associated with the fault. This may for example, identify the unit, slot, port, and possibly logical ports (VLAN, LAG) from which the fault occurs. The format of the source string is: 'TYPE=#:TYPE=#:...' where the TYPE may be one of 'unit' or 'slot' or 'port' or 'VLAN' or 'LAG'. For example: 'unit=3:slot=1:port=2' - indicates the trap comes from port 2 in slot 1 of the switch #3 in the stack. 'unit=2:VLAN=10' - indicates the trap comes from VLAN=10 in unit 2. 'unit=1' - indicates the trap comes from unit 1." ::= { dellAlarmGroup 3 } dellTrapSeqNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Since SNMP traps are transported using UDP, there is a possibility for the trap to be lost in transit. To allow the NMS the ability to detect this possibility, all traps will include a trap sequence number as part of its variable binding list. The trap sequence number may be reset each time the system reboots and will increment for each trap sent from the device. When a missing trap sequence number is detected the NMS may be able to refresh its state of the switch to determine what event it may have missed." ::= { dellAlarmGroup 4 } dellTrapTimeStamp OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The trap header includes the system up time which mark when the trap was generated, but often it is important to know the absolute time when the trap was generated. This time stamp is based on GMT (universal time) time zone. This will allow the timestamps to be correlated consistently across a large network." ::= { dellAlarmGroup 5 } --------------------------------------------------------------------------- -- Trap definitions: -- All traps must have at least the following VAR-BIND: -- dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, -- dellTrapInfo. -- -- The trap may include additional variables which may be defined in the -- object list following these objects for proprietary traps. -- -- For standard traps, this rule does not apply. --------------------------------------------------------------------------- hwResourceOverflow NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that a switch hardware resource overflowed. The dellTrapSource should indicate the unit number whereas dellTrapInfo should identify the resource that overflowed." ::= { dellLan 500 } swResourceOverflow NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that a switch software resource overflowed. The dellTrapSource should indicate the unit number whereas dellTrapInfo should identify the resource that overflowed (e.g. maximum VLAN/LAG/MACs/IPs exceeded)." ::= { dellLan 510 } configChanged NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that the switch configuration has changed. The dellTrapSource should indicate the source of the change such as the unit, slot, port, VLAN, LAG, etc. The dellTrapInfo may indicate additional information regarding the change." ::= { dellLan 520 } -- This trap may be implementation dependent. If it does not apply to a -- particular implementation then it may be safely ignored. resetRequired NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "This trap indicates that in order to perform the last SET request, a reset operation of the router/bridge is required. This may occur for any number of reasons such as if the change affects the routing protocols to be switched from SPF to STP. This trap warns the user to manually reset the switch using either physical or software reset." ::= { dellLan 530 } endTftp NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "This trap indicates that the device finished a TFTP transaction with the management station. The dellTrapInfo field will provide TFTP exit code and name/type of the file being transferred." ::= { dellLan 540 } abortTftp NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "This trap indicates that in the device aborted a TFTP session with the management station. The dellTrapInfo field will provide TFTP exit code and name/type of the file being transferred." ::= { dellLan 550 } startTftp NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Informational trap indicating that the device has intiated a TFTP session. dellTrapInfo will contain the name/type of the file being transferred." ::= { dellLan 560 } linkFailure NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Link failure detected, no backup available. The dellTrapSource should indicate the fail link." ::= { dellLan 570 } linkFailureSwitchBackUp NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Automantic switchover to backup link because of main link fault. The dellTrapSource indicates the backup link coming on, and the dellTrapInfo indicates the failed link." ::= { dellLan 580 } mainLinkUp NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Communication returned to main link. The dellTrapSource indicates the main link coming up, and the dellTrapInfo indicates the backup link." ::= { dellLan 590 } errorsDuringInit NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "This trap indicates that the an error occured during initialization phase of the switch. Additional information is provided in the dellTrapInfo field." ::= { dellLan 600 } vlanDynPortAdded NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that a port was dynamically added to the VLAN. The dellTrapSource will indicate the VLAN, and the dellTrapInfo will indicate the port being added." ::= { dellLan 610 } vlanDynPortRemoved NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that a port was dynamically removed from a VLAN. The dellTrapSource will indicate the VLAN, and the dellTrapInfo will indicate the port being removed." ::= { dellLan 620 } -- === Begin Zero-Hop Edge Routing === -- The following traps are related to routing. These traps may be software -- implementation dependent. If these are not appropriate they may be -- ignored. ipZhrReqStaticConnNotAccepted NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "The requested static connection was not accepted because there is no available IP virtual address to allocate to it." ::= { dellLan 630 } ipZhrVirtualIpAsSource NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "The virtual IP address appeared as a source IP. All the connections using it will be deleted and it will not be further allocated to new connections." ::= { dellLan 640 } ipZhrNotAllocVirtualIp NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "The source IP address sent an ARP specifying a virtual IP which was not allocated for this source. This virtual IP will not be allocated to connections of this specific source IP." ::= { dellLan 650 } -- === End Zero-Hop Edge Routing === -- === Start Stacking specific Traps === -- The following traps are related to stacking. If the switch does not -- support stacking, these may safely be ignored. -- -- Note that these traps define a set of conditions based upon a particular -- operational paradigm of stacking. If these traps do not quite match -- a given implementation then new traps may be defined for the feature in the -- vendor specific section of the mibs. stackMasterFailed NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that the stack master unit has failed. This trap is generated by the new master when it takes over the stack. The dellTrapSource should be the new master unit #, and the dellTrapInfo should identify the old master unit #." ::= { dellLan 660 } stackNewMasterElected NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates when a new master has been elected. This is different from a stack failure in that the master has not failed but for some reason a new master has been elected (e.g. the user requested a new master. The trap should be generated by the new master. the dellTrapSource should identify the new master, and the dellTrapInfo should identify the old master." ::= { dellLan 670 } stackMemberUnitFailed NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that a member of the stack has failed. This condition is detected by the master unit so the dellTrapSource should indicate the master unit ID and the dellTrapInfo should indicate the member unit that failed." ::= { dellLan 680 } stackNewMemberUnitAdded NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that a new member unit has been added to the stack. This trap is generated by the master unit so the dellTrapSource should indicate the master unit ID, and the dellTrapInfo should identify the new unit ID." ::= { dellLan 690 } stackMemberUnitRemoved NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that a member unit has been removed from the stack. The dellTrapSource indicates the master unit ID and the dellTrapInfo indicates the unit ID being removed." ::= { dellLan 700 } stackSplitMasterReport NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that the stack has split into two distinct stacks which means that each stack may end up with its own master temporarily until the stack is rejoined. This is possibly different from the stackMemberUnitFailed trap, which indicates only a single unit failure. This trap indicates that the master has lost track of part of the stack membership so that the other units may elect their own master. The dellTrapSource should indicate the master unit ID and the dellTrapInfo should identify the units that are split from the main stack." ::= { dellLan 710 } stackSplitNewMasterReport NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that the stack has split into two distinct stacks which means that each stack may end up with its own master temporarily until the stack is rejoined. This trap is generated by the new master unit elected in the split sub-stack. The dellTrapSource should identify the new master unit ID, and the dellTrapInfo should identify the old master unit ID before the split occured." ::= { dellLan 720 } stackRejoined NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that previously split stack has rejoined. The rejoined stack will elect a master and this trap should be generated by the elected master. The dellTrapSource should indicate the master unit ID and the dellTrapInfo should list the unit IDs of the members." ::= { dellLan 730 } stackLinkFailed NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates a failure in one of the stacking link. If this stack was connected in a ring, then the failure of a stacking link results in a chain stack instead of a ring. Another failure in the chain topology would result in a split stack. If the stack is connected in a meshed or star topology then multiple link failure may be tolerated. This trap may be generated by any unit within the stack and must indicate the source of the failure. The dellTrapSource should identify one end of the link where the failure is detected. The dellTrapInfo may provide additional information about the failure." ::= { dellLan 740 } -- === End Stacking specific Traps === dhcpAllocationFailure NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "DHCP failed to allocate an IP address to a requesting host because of memory shortage or inadequate configuration of available IP addresses." ::= { dellLan 750 } dot1dStpPortStateForwarding NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "The trap is sent by a bridge when any of its configured ports transitions from the Learning state to the Forwarding state." ::= { dellLan 760 } dot1dStpPortStateNotForwarding NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "The trap is sent by a bridge when any of its configured ports transitions from the Forwarding state to the Blocking state." ::= { dellLan 770 } policyDropPacketTrap NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that the packet drop due to the policy. This trap may result in a huge number of trap packets and should be used only for debugging purposes. The number of traps sent per time period is user configurable and the user may enable/disable generation of this trap." ::= { dellLan 780 } policyForwardPacketTrap NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that the packet has forward based on policy. The number of traps sent per time period is user configurable and the user may enable/disable generation of this trap." ::= { dellLan 790 } igmpV1MsgReceived NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "An IGMP Message of v1 received on a given interface. The dellTrapSource should indicate the interface." ::= { dellLan 800 } vrrpEntriesDeleted NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "One or more VRRP entries deleted due to IP interface deletion or transition. " ::= { dellLan 810 } trunkPortAddedTrap NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Informational trap indicating that a port is added to a trunk. The dellTrapSource should indicate the trunk to which the port is added. The dellTrapInfo should indicate the port being added." ::= { dellLan 820 } trunkPortRemovedTrap NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "This warning is generated when a port removed from a trunk. The dellTrapSource should indicate the trunk from which the port is removed. The dellTrapInfo should indicate the port being removed." ::= { dellLan 830 } -- trunkPortNotCapableTrap is a duplicate OID as above. we may end up on no using the following trap. So commenting for time being --trunkPortNotCapableTrap NOTIFICATION-TYPE -- OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, -- dellTrapSource, dellTrapSeverity, -- dellTrapInfo } -- STATUS current -- -- DESCRIPTION -- "Informational trap indicating that a port can not be added to -- a trunk because of device limitations or different swIfType. -- The dellTrapSource should identify the trunk whereas the -- dellTrapInfo should indicate the port being added and any additional -- information." -- ::= { dellLan 830 } lockPortTrap NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Informational trap indicating that a port that is blocked from MAC learning has receive a frame with new source Mac Address. The dellTrapSource should identify the port and the dellTrapInfo should specify the new MAC address received." ::= { dellLan 840 } vlanDynVlanAdded NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that a dynamic VLAN has been added via GVRP. The dellTrapSource should identify the VLAN being added." ::= { dellLan 850 } vlanDynVlanRemoved NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that a dynamic VLAN has been removed via GVRP. The dellTrapSource should identify the VLAN being removed." ::= { dellLan 860 } vlanDynamicToStatic NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that a dynamic VLAN has been made static. The dellTrapSource should identify the VLAN." ::= { dellLan 870 } vlanStaticToDynamic NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that a static VLAN has been made dynamic. The dellTrapSource should identify the VLAN." ::= { dellLan 880 } envMonFanStateChange NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Trap indicating the fan state. The dellTrapSource should identify the exact fan index if there are multiple fans. The dellTrapInfo may provide additional info relating to the fan new state." ::= { dellLan 890 } envMonPowerSupplyStateChange NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Trap indicating the power supply state. The dellTrapSource should identify the exact power supply. The dellTrapInfo may provide additional info regarding the power state." ::= { dellLan 900 } envMonTemperatureRisingAlarm NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Trap indicating that the temperature in the device has exceeded the device specific safe temperature threshold." ::= { dellLan 910 } copyFinished NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Informational trap indicating that the device has finished a copy operation successfully." ::= { dellLan 920 } copyFailed NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Informational trap indicating that the copy operation has failed." ::= { dellLan 930 } dot1xPortStatusAuthorizedTrap NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Informational trap indicating that port 802.1x status is authorized." ::= { dellLan 940 } dot1xPortStatusUnauthorizedTrap NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Warning trap is indicating that port 802.1x status is unAuthorized." ::= { dellLan 950 } broadcastStormDetected NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that a broadcast storm has been detected. The dellTrapSource should indicate the port on which the broadcast storm is detected." ::= { dellLan 960 } stpElectedAsRoot NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that the switch has been elected as the new STP root." ::= { dellLan 970 } stpNewRootElected NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that a new root has been elected. The dellTrapSource should indicate the member unit number and the dellTrapInfo should provide information on the new root." ::= { dellLan 980 } igmpElectedAsQuerier NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that this switch has been elected as the new IGMP snooping querier." ::= { dellLan 990 } invalidUserLoginAttempted NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that an invalid user tries to login to the CLI or Web. The dellTrapSource should indicate the unit member ID and the dellTrapInfo should indicate whether the login attempt is on the CLI or Web and the IP address from which the attempt was made." ::= { dellLan 1000 } managementACLViolation NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that an SNMP request or CLI/Web access request was received but does not meet the management ACL rules. For example, if the request comes from an invalid IP address or has the wrong SNMP community string (for V1/2c) or is not authenticated for SNMPv3, etc. The dellTrapSource should indicate the unit # and the dellTrapInfo should indicate which interface (web, cli, snmp) is violated and the source IP address of the request." ::= { dellLan 1010 } sfpInserted NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that an SFP was inserted into the system. The dellTrapSource should indicate the unit # and the dellTrapInfo should indicate on which interface was the SFP inserted." ::= { dellLan 1020 } sfpRemoved NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that an SFP was removed from the system. The dellTrapSource should indicate the unit # and the dellTrapInfo should indicate from which interface was the SFP removed." ::= { dellLan 1030 } xfpInserted NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that an XFP was inserted into the system. The dellTrapSource should indicate the unit # and the dellTrapInfo should indicate on which interface was the XFP inserted." ::= { dellLan 1040 } xfpRemoved NOTIFICATION-TYPE OBJECTS { dellTrapTimeStamp, dellTrapSeqNum, dellTrapSource, dellTrapSeverity, dellTrapInfo } STATUS current DESCRIPTION "Indicates that an XFP was removed from the system. The dellTrapSource should indicate the unit # and the dellTrapInfo should indicate from which interface was the XFP removed." ::= { dellLan 1050 } END