-- Box Services MIB overview: -- Box Services MIB falls under dnOS MIB node of the private subtree. DNOS-BOXSERVICES-PRIVATE-MIB DEFINITIONS ::= BEGIN -- Broadcom DNOS Box Services MIB -- Copyright 2017-2020 Broadcom. -- This SNMP Management Information Specification -- embodies Broadcom's confidential and proprietary -- intellectual property. Broadcom retains all title -- and ownership in the Specification including any revisions. -- This Specification is supplied "AS IS", Broadcom -- makes no warranty, either expressed or implied, -- as to the use, operation, condition, or performance of the -- Specification. IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Integer32, Gauge32 FROM SNMPv2-SMI TEXTUAL-CONVENTION, TruthValue FROM SNMPv2-TC DisplayString FROM RFC1213-MIB CounterBasedGauge64 FROM HCNUM-TC DeciInteger32, MilliInteger32, DBmHundreths FROM DNOS-TC dnOS FROM DELL-REF-MIB; fastPathBoxServices MODULE-IDENTITY LAST-UPDATED "202106020000Z" -- 02 Jun 2021 12:00:00 GMT ORGANIZATION "Dell" CONTACT-INFO "" DESCRIPTION "The Broadcom Private MIB for DNOS Box Services Feature." -- Revision history. REVISION "202106020000Z" -- 02 Jun 2021 12:00:00 GMT DESCRIPTION "boxServicesFiberPortsOpticsInfoTable(19) is added to display the Fiber port optics information." REVISION "202005210000Z" -- 21 May 2020 12:00:00 GMT DESCRIPTION "Support for Fiber port optics Diagonostics." REVISION "201806300000Z" -- 30 June 2018 12:00:00 GMT DESCRIPTION "General cleanup to make MIB more conformant with SMIv2." REVISION "201708040000Z" -- 04 Aug 2017 12:00:00 GMT DESCRIPTION "Max Access of Dying Gasp trap updated." REVISION "201101260000Z" -- 26 Jan 2011 12:00:00 GMT DESCRIPTION "Postal address updated." REVISION "200802220000Z" -- 22 Feb 2008 12:00:00 GMT DESCRIPTION "Dell branding related changes." ::= { dnOS 43 } BoxsTemperatureStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The temperature state" SYNTAX INTEGER { low(0), normal(1), warning(2), critical(3), shutdown(4), notpresent(5), notoperational(6) } --************************************************************************************** -- boxServicesGroup -- -- This group provides configuration and status of the Box Services -- feature. -- --************************************************************************************** boxServicesGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 1 } --************************************************************************************** -- Some scalars boxServicesNormalTempRangeMin OBJECT-TYPE SYNTAX Integer32 (-100..100) MAX-ACCESS read-write STATUS current DESCRIPTION " Lower boundary of normal temperature range." ::= { boxServicesGroup 1 } boxServicesNormalTempRangeMax OBJECT-TYPE SYNTAX Integer32 (-100..100) MAX-ACCESS read-write STATUS current DESCRIPTION " Upper boundary of normal temperature range." ::= { boxServicesGroup 2 } boxServicesTemperatureTrapEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable or disable temperature change event trap, raised when temperature crosses boundaries of normal range" ::= { boxServicesGroup 3 } boxServicesPSMStateTrapEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable or disable Power Supply Module state change trap." ::= { boxServicesGroup 4 } boxServicesFanStateTrapEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable or disable Fan state change trap." ::= { boxServicesGroup 5 } boxsPwrUsageHistoryUnitSampleInterval OBJECT-TYPE SYNTAX INTEGER (30..86400) MAX-ACCESS read-write STATUS current DESCRIPTION "Interval at which power consumption data needs to be collected." ::= { boxServicesGroup 10 } boxsPwrUsageHistoryUnitMaxSamples OBJECT-TYPE SYNTAX INTEGER (1..168) MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum number of samples to keep." ::= { boxServicesGroup 11 } boxServicesThermalShutdownSensor OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The number of the sensor which initiated thermal shutdown." ::= { boxServicesGroup 13 } boxServicesThermalShutdownTemperature OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The temperature of the sensor which initiated thermal shutdown." ::= { boxServicesGroup 14 } --************************************************************************************** -- boxServicesFans boxServicesFansTable OBJECT-TYPE SYNTAX SEQUENCE OF BoxServicesFansEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Fan Table" ::= { boxServicesGroup 6 } boxServicesFansEntry OBJECT-TYPE SYNTAX BoxServicesFansEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Box Services Fan Entry" INDEX { boxServicesFanUnitIndex , boxServicesFansIndex } ::= { boxServicesFansTable 1 } BoxServicesFansEntry ::= SEQUENCE { boxServicesFanUnitIndex Unsigned32, boxServicesFansIndex Integer32, boxServicesFanItemType INTEGER, boxServicesFanItemState INTEGER, boxServicesFanSpeed Integer32, boxServicesFanDutyLevel Integer32 } boxServicesFanUnitIndex OBJECT-TYPE SYNTAX Unsigned32 (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "Unit index for an entry in the Box Services Fan Table" ::= { boxServicesFansEntry 6 } boxServicesFansIndex OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique index of fan table entry" ::= { boxServicesFansEntry 1 } boxServicesFanItemType OBJECT-TYPE SYNTAX INTEGER { fixed(1), removable(2), fixedAC(3), removableDC(4), fixedDC(5), removableAC(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of fan" ::= { boxServicesFansEntry 2 } boxServicesFanItemState OBJECT-TYPE SYNTAX INTEGER { notpresent(1), operational(2), failed(3), powering(4), nopower(5), notpowering(6), incompatible(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of fan. nopower(5) - This state means the fan is present but no AC is connected." ::= { boxServicesFansEntry 3 } boxServicesFanSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The speed of fan" ::= { boxServicesFansEntry 4} boxServicesFanDutyLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The duty level of fan, in percents" ::= { boxServicesFansEntry 5} boxsDyingGaspEventReason OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Dying Gasp Event Reason code string" ::= { boxServicesGroup 17 } --************************************************************************************** -- boxServicesPowSupplies boxServicesPowSuppliesTable OBJECT-TYPE SYNTAX SEQUENCE OF BoxServicesPowSuppliesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Power Supply" ::= { boxServicesGroup 7 } boxServicesPowSuppliesEntry OBJECT-TYPE SYNTAX BoxServicesPowSuppliesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Box Services Power Supply Entry" INDEX { boxServicesPowerSuppUnitIndex, boxServicesPowSupplyIndex } ::= { boxServicesPowSuppliesTable 1 } BoxServicesPowSuppliesEntry ::= SEQUENCE { boxServicesPowerSuppUnitIndex Unsigned32, boxServicesPowSupplyIndex Integer32, boxServicesPowSupplyItemType INTEGER, boxServicesPowSupplyItemState INTEGER } boxServicesPowerSuppUnitIndex OBJECT-TYPE SYNTAX Unsigned32 (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "Unit index for an entry in the Box Services Power Supply Table" ::= { boxServicesPowSuppliesEntry 4 } boxServicesPowSupplyIndex OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique index of Power Supply Table entry" ::= { boxServicesPowSuppliesEntry 1 } boxServicesPowSupplyItemType OBJECT-TYPE SYNTAX INTEGER { fixed(1), removable(2), fixedAC(3), removableDC(4), fixedDC(5), removableAC(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of Power Supply" ::= { boxServicesPowSuppliesEntry 2 } boxServicesPowSupplyItemState OBJECT-TYPE SYNTAX INTEGER { notpresent(1), operational(2), failed(3), powering(4), nopower(5), notpowering(6), incompatible(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of Power Supply. nopower(5) - This state means the Power Supply is present but no AC is connected. incompatible(7) - This state is possible on boards capable of pluggable Power Supplies." ::= { boxServicesPowSuppliesEntry 3 } -- Box Services Unit Power Usage History table boxsUnitPwrUsageHistoryTable OBJECT-TYPE SYNTAX SEQUENCE OF BoxsUnitPwrUsageHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table providing configuration and status of Power Usage History feature" ::= { boxServicesGroup 9 } boxsUnitPwrUsageHistoryEntry OBJECT-TYPE SYNTAX BoxsUnitPwrUsageHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Power Usage History Table for a Unit." INDEX { boxsPwrUsageHistoryUnitIndex, boxsPwrUsageHistoryUnitSampleIndex } ::= { boxsUnitPwrUsageHistoryTable 1 } BoxsUnitPwrUsageHistoryEntry::= SEQUENCE { boxsPwrUsageHistoryUnitIndex INTEGER, boxsPwrUsageHistoryUnitSampleIndex INTEGER, boxsPwrUsageHistoryUnitSampleTime DisplayString, boxsPwrUsageHistoryUnitPowerConsumption Integer32, boxsPwrUsageHistoryStackPowerConsumption Integer32 } boxsPwrUsageHistoryUnitIndex OBJECT-TYPE SYNTAX INTEGER (1..12) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a unique index for an entry in the boxsUnitPwrUsageHistoryTable. A non-zero value indicates the unitIndex for the corresponding unit entry in the Power Usage History Table." ::= { boxsUnitPwrUsageHistoryEntry 1 } boxsPwrUsageHistoryUnitSampleIndex OBJECT-TYPE SYNTAX INTEGER (1..168) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a unique index for an entry in the boxsUnitPwrUsageHistoryTable. A non-zero value indicates the sampleIndex for the corresponding sample entry in the Power Usage History Table." ::= { boxsUnitPwrUsageHistoryEntry 2 } boxsPwrUsageHistoryUnitSampleTime OBJECT-TYPE SYNTAX DisplayString (SIZE(1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Time at which the Sample was collected." ::= { boxsUnitPwrUsageHistoryEntry 3} boxsPwrUsageHistoryUnitPowerConsumption OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Power Consumption (mWatts) at the time of collecting the given sample." ::= { boxsUnitPwrUsageHistoryEntry 4 } boxsPwrUsageHistoryStackPowerConsumption OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Power Consumption (mWatts) per Stack at the time of collecting the given sample." ::= { boxsUnitPwrUsageHistoryEntry 5 } --************************************************************************************** -- boxServicesTempSensors boxServicesTempSensorsTable OBJECT-TYPE SYNTAX SEQUENCE OF BoxServicesTempSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Temperature sensor" ::= { boxServicesGroup 8 } boxServicesTempSensorsEntry OBJECT-TYPE SYNTAX BoxServicesTempSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Box Services Temperature Sensor Entry" INDEX { boxServicesUnitIndex, boxServicesTempSensorIndex } ::= { boxServicesTempSensorsTable 1 } BoxServicesTempSensorsEntry ::= SEQUENCE { boxServicesUnitIndex Unsigned32, boxServicesTempSensorIndex Unsigned32, boxServicesTempSensorType INTEGER, boxServicesTempSensorState BoxsTemperatureStatus, boxServicesTempSensorTemperature Integer32 } boxServicesUnitIndex OBJECT-TYPE SYNTAX Unsigned32 (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "Unit index for an entry in the Box Services Temperature Sensor Table" ::= { boxServicesTempSensorsEntry 1 } boxServicesTempSensorIndex OBJECT-TYPE SYNTAX Unsigned32 (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique index of temperature sensor table entry" ::= { boxServicesTempSensorsEntry 2 } boxServicesTempSensorType OBJECT-TYPE SYNTAX INTEGER { fixed(1), removable(2), fixedAC(3), removableDC(4), fixedDC(5), removableAC(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of temperature sensor" ::= { boxServicesTempSensorsEntry 3 } boxServicesTempSensorState OBJECT-TYPE SYNTAX BoxsTemperatureStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The state of temperature sensor" ::= { boxServicesTempSensorsEntry 4 } boxServicesTempSensorTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature value reported by sensor" ::= { boxServicesTempSensorsEntry 5 } boxServicesTempUnitTable OBJECT-TYPE SYNTAX SEQUENCE OF BoxServicesTempUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Temperature status table" ::= { boxServicesGroup 15 } boxServicesTempUnitEntry OBJECT-TYPE SYNTAX BoxServicesTempUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Box Services Temperature Unit Entry" INDEX { boxServicesTempUnitIndex } ::= { boxServicesTempUnitTable 1 } BoxServicesTempUnitEntry ::= SEQUENCE { boxServicesTempUnitIndex Unsigned32, boxServicesTempUnitState BoxsTemperatureStatus, boxServicesTempUnitTemperature Integer32 } boxServicesTempUnitIndex OBJECT-TYPE SYNTAX Unsigned32 (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "Unit index for an entry in the Box Services Temperature Unit Table" ::= { boxServicesTempUnitEntry 1 } boxServicesTempUnitState OBJECT-TYPE SYNTAX BoxsTemperatureStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature state of the unit" ::= { boxServicesTempUnitEntry 2 } boxServicesTempUnitTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The highest temperature currently reported by any sensor on the unit" ::= { boxServicesTempUnitEntry 3 } boxServicesFiberPortsOpticsTable OBJECT-TYPE SYNTAX SEQUENCE OF BoxServicesFiberPortsOpticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Fiber ports optics data table" ::= { boxServicesGroup 18 } boxServicesFiberPortsOpticsEntry OBJECT-TYPE SYNTAX BoxServicesFiberPortsOpticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Box Services Fiber ports optics Entry" INDEX { boxServicesFiberPortIndex } ::= { boxServicesFiberPortsOpticsTable 1 } BoxServicesFiberPortsOpticsEntry ::= SEQUENCE { boxServicesFiberPortIndex Unsigned32, boxServicesFiberPortOpticsTemperature DeciInteger32, boxServicesFiberPortOpticsVoltage MilliInteger32, boxServicesFiberPortOpticsCurrent DeciInteger32, boxServicesFiberPortOpticsPowerOut DBmHundreths, boxServicesFiberPortOpticsPowerIn DBmHundreths, boxServicesFiberPortOpticsTxFault TruthValue, boxServicesFiberPortOpticsLos TruthValue, boxServicesFiberPortOpticsFaultStatus DisplayString } boxServicesFiberPortIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Port index for an entry in the Box Services Fiber ports optics table" ::= { boxServicesFiberPortsOpticsEntry 1 } boxServicesFiberPortOpticsTemperature OBJECT-TYPE SYNTAX DeciInteger32 UNITS "DEGREES" MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature measured at this fiber port in degrees Celsius." ::= { boxServicesFiberPortsOpticsEntry 2 } boxServicesFiberPortOpticsVoltage OBJECT-TYPE SYNTAX MilliInteger32 UNITS "Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage measured at this fiber port." ::= { boxServicesFiberPortsOpticsEntry 3 } boxServicesFiberPortOpticsCurrent OBJECT-TYPE SYNTAX DeciInteger32 UNITS "Milliamps" MAX-ACCESS read-only STATUS current DESCRIPTION "The current measured at this fiber port." ::= { boxServicesFiberPortsOpticsEntry 4 } boxServicesFiberPortOpticsPowerOut OBJECT-TYPE SYNTAX DBmHundreths UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The output power measured at this fiber port." ::= { boxServicesFiberPortsOpticsEntry 5 } boxServicesFiberPortOpticsPowerIn OBJECT-TYPE SYNTAX DBmHundreths UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The input power measured at this fiber port." ::= { boxServicesFiberPortsOpticsEntry 6 } boxServicesFiberPortOpticsTxFault OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The TX fault status of fiber port." ::= { boxServicesFiberPortsOpticsEntry 7 } boxServicesFiberPortOpticsLos OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The LOS status of fiber port." ::= { boxServicesFiberPortsOpticsEntry 8 } boxServicesFiberPortOpticsFaultStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The fault status of fiber port." ::= { boxServicesFiberPortsOpticsEntry 9 } boxServicesFiberPortsOpticsInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF BoxServicesFiberPortsOpticsInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Fiber ports optics info data table" ::= { boxServicesGroup 19 } boxServicesFiberPortsOpticsInfoEntry OBJECT-TYPE SYNTAX BoxServicesFiberPortsOpticsInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Box Services Fiber ports optics info Entry" INDEX { boxServicesFiberPortsOpticsInfoPortIndex } ::= { boxServicesFiberPortsOpticsInfoTable 1 } BoxServicesFiberPortsOpticsInfoEntry ::= SEQUENCE { boxServicesFiberPortsOpticsInfoPortIndex Unsigned32, boxServicesFiberPortsOpticsInfoVendorName DisplayString, boxServicesFiberPortsOpticsInfoLinkLength50um Unsigned32, boxServicesFiberPortsOpticsInfoLinkLength62dot5um Unsigned32, boxServicesFiberPortsOpticsInfoSerialNumber DisplayString, boxServicesFiberPortsOpticsInfoPartNumber DisplayString, boxServicesFiberPortsOpticsInfoNominalBitRate Unsigned32, boxServicesFiberPortsOpticsInfoRevision DisplayString, boxServicesFiberPortsOpticsInfoCompliance DisplayString } boxServicesFiberPortsOpticsInfoPortIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Port index for an entry in the Box Services Fiber ports optics info table" ::= { boxServicesFiberPortsOpticsInfoEntry 1 } boxServicesFiberPortsOpticsInfoVendorName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Vendor Name of the fiber port." ::= { boxServicesFiberPortsOpticsInfoEntry 2 } boxServicesFiberPortsOpticsInfoLinkLength50um OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Link Length(50um) of the fiber port." ::= { boxServicesFiberPortsOpticsInfoEntry 3 } boxServicesFiberPortsOpticsInfoLinkLength62dot5um OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Link Length(62.5um) of the fiber port." ::= { boxServicesFiberPortsOpticsInfoEntry 4 } boxServicesFiberPortsOpticsInfoSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Serial Number of the fiber port." ::= { boxServicesFiberPortsOpticsInfoEntry 5 } boxServicesFiberPortsOpticsInfoPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Part Number of the fiber port." ::= { boxServicesFiberPortsOpticsInfoEntry 6 } boxServicesFiberPortsOpticsInfoNominalBitRate OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Nominal Bit Rate (Mbps) of the fiber port." ::= { boxServicesFiberPortsOpticsInfoEntry 7 } boxServicesFiberPortsOpticsInfoRevision OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Revision of the fiber port." ::= { boxServicesFiberPortsOpticsInfoEntry 8 } boxServicesFiberPortsOpticsInfoCompliance OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Compliance of the fiber port." ::= { boxServicesFiberPortsOpticsInfoEntry 9 } --************************************************************************************** -- boxServicesNotificationsGroup -- -- This group provides notification definitions for the Box Services -- feature. -- --************************************************************************************** boxServicesNotificationsGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 2 } --************************************************************************************** -- boxServices notification definitions boxsItemStateChangeEvent OBJECT-TYPE SYNTAX INTEGER { insertion(1), removal(2), becomeoperational(3), failure(4), losepower(5) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This event describes states of the fan or Power Supply. insertion - hot-pluggable fan or Power Supply was inserted removal - hot-pluggable fan or Power Supply was removed becomeoperational - fan or Power Supply became operational after failure state failure - fan or Power Supply failure happened, i.e. it is not able to perform its functions losepower - a Power Supply was operational, but the power to it has been disconnected or has failed" ::= { boxServicesNotificationsGroup 1 } boxsTemperatureChangeEvent OBJECT-TYPE SYNTAX INTEGER { abovethreshold(1), belowthreshold(2), withinnormalrange(3) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This event describes change of the temperature. To avoid flipping on boundary conditions, it is allowed to send the trap taking into account some margin around thresholds. abovethreshold - temperature increased and crossed upper threshold value belowthreshold - temperature decreased and crossed lower threshold value withinnormalrange - temperature returned to normal range (between threshold)" ::= { boxServicesNotificationsGroup 2 } boxsTemperatureStatusCurrentEvent OBJECT-TYPE SYNTAX BoxsTemperatureStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This event describes the current status of a switch." ::= { boxServicesNotificationsGroup 3 } boxsTemperatureStatusPreviousEvent OBJECT-TYPE SYNTAX BoxsTemperatureStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This event describes the previous status of a switch." ::= { boxServicesNotificationsGroup 4 } --************************************************************************************** -- Traps --************************************************************************************** fastPathBoxServicesTraps OBJECT IDENTIFIER ::= { fastPathBoxServices 0 } boxsFanStateChange NOTIFICATION-TYPE OBJECTS { boxServicesFansIndex, boxsItemStateChangeEvent } STATUS current DESCRIPTION "Trap is sent when fan state change happens." ::= { fastPathBoxServicesTraps 1 } boxsPowSupplyStateChange NOTIFICATION-TYPE OBJECTS { boxServicesPowSupplyIndex, boxsItemStateChangeEvent } STATUS current DESCRIPTION "Trap is sent when Power Supply state change happens." ::= { fastPathBoxServicesTraps 2 } boxsTemperatureChange NOTIFICATION-TYPE OBJECTS { boxServicesTempSensorIndex, boxsTemperatureChangeEvent } STATUS obsolete DESCRIPTION "Trap is sent when temperature is changing and crossing any of the thresholds" ::= { fastPathBoxServicesTraps 3 } boxsThermalShutdown NOTIFICATION-TYPE OBJECTS { boxServicesThermalShutdownSensor, boxServicesThermalShutdownTemperature } STATUS current DESCRIPTION "Trap is sent when thermal shutdown is initiated." ::= { fastPathBoxServicesTraps 4 } boxsTemperatureStateChange NOTIFICATION-TYPE OBJECTS { boxServicesTempUnitIndex, boxsTemperatureStatusCurrentEvent, boxsTemperatureStatusPreviousEvent } STATUS current DESCRIPTION "Trap is sent when the system temperature crosses a threshold. To avoid rapid flapping between states, a hysteresis may be applied." ::= { fastPathBoxServicesTraps 5 } boxsDyingGaspEventChange NOTIFICATION-TYPE OBJECTS { boxsDyingGaspEventReason } STATUS current DESCRIPTION "Trap is sent when the Dying Gasp event is generated." ::= { fastPathBoxServicesTraps 6 } --************************************************************************************** -- Locator LED manage group -- -- This group provides manage definitions for the Locator LED feature. -- --************************************************************************************** boxsLocatorLedConfigGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 4 } boxsLocatorLedUnit OBJECT-TYPE SYNTAX INTEGER (1..12) MAX-ACCESS read-write STATUS current DESCRIPTION "Spesifies unit number where Locator LED should blink on. This is write-only value. It always returns '0' on request." ::= { boxsLocatorLedConfigGroup 1 } boxsLocatorLedTime OBJECT-TYPE SYNTAX INTEGER (20..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates time period in seconds for Locator LED blinking. The range is from 20 to 3600 seconds with a default value of 20 seconds. This is write-only value. It always returns '0' on request." ::= { boxsLocatorLedConfigGroup 2 } boxsLocatorLedEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Starts the Locator LED blinking. If boxsLocatorLedUnit has not been set, the manager unit number will be used. If boxsLocatorLedTime has not been set, the default value (20 seconds) will be used. This is write-only value. It always returns '0' on request." ::= { boxsLocatorLedConfigGroup 3 } END