-- -- Dell Management Module MIB -- Management Information Base -- -- This MIB is intended for use with the OpenManage Enterprise-Modular management software. -- -- Note that the Dell Management Module MIB file is published in both types of SMI (Structure -- of Managed Information). This copy of the Dell Management Module MIB file is the SMIv2 version of the MIB file. -- -- Copyright (c) 2020 Dell Inc. -- -- Last Changed Revision: 1 -- Last Changed Date: 2020-01-22 13:00:00 -0500 (Wed, 22 Jan 2020) -- ------------------------------------------------------------------------------ -- Begin MIB ------------------------------------------------------------------------------ DELL-MM-MIB-SMIv2 DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, enterprises FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC OBJECT-GROUP,NOTIFICATION-GROUP FROM SNMPv2-CONF; ------------------------------------------------------------------------------ -- Textual Conventions ------------------------------------------------------------------------------ DellString ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "General string type." SYNTAX OCTET STRING (SIZE (0..1023)) -- -- Management Module Types -- DellMmType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Management Module Types." SYNTAX INTEGER { other(1), -- the MM type is not one of the following unknown(2), -- the MM type is unknown mxMM(3) -- MX Chassis (MM) } DellStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Status Information." SYNTAX INTEGER { other(1), -- the status of the object is not one of the following: unknown(2), -- the status of the object is unknown -- (not known or monitored) ok(3), -- the status of the object is ok nonCritical(4), -- the status of the object is warning, non-critical critical(5), -- the status of the object is critical (failure) nonRecoverable(6) -- the status of the object is non-recoverable (dead) } ------------------------------------------------------------------------------- -- DellPowerReading is a string representation of a floating point value, -- having exactly 3 digits of precision, and a maximum of 31 characters. -- -- DellChassisPowerIndexRange defines the possible chassis power instances -- in this MIB. -- -- DellPSUIndexRange defines the possible Power Supply Unit (PSU) -- instances, per chassis power instance, in this MIB. -- -- DellPSUCapable is an enumeration of PSU presence and/or monitoring -- capabilities. -- -- DellTemperatureReading is an integer value, expressed in degrees Celsius. ------------------------------------------------------------------------------- DellPowerReading ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Power Reading." SYNTAX OCTET STRING (SIZE (0..32)) DellPowerIndexRange ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Integer with a range of (1..1)." SYNTAX INTEGER (1..1) DellPSUIndexRange ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Integer with a range of (1..6)." SYNTAX INTEGER (1..6) DellPSUCapable ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Power Supply Information." SYNTAX INTEGER { absent(1), -- power supply is not present none(2), -- no power monitoring abilities basic(3) -- basic power monitoring abilities } DellTemperatureReading ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Temperature Reading." SYNTAX INTEGER ------------------------------------------------------------------------------- -- DellTimestamp is defined in the displayable format: -- -- yyyymmddHHMMSS.uuuuuuDooo -- -- where yyyy is the year, mm is the month number, dd is the day of the month, -- HHMMSS are the hours, minutes and seconds, respectively, uuuuuu is the -- number of microseconds, D is the UTC offset direction, and ooo is the -- offset from UTC, in minutes. -- -- Note: D is a plus (+) sign if east of UTC, and a minus (-) if west of UTC. -- -- For example, Wednesday, May 25, 1994, at 1:30:15 PM EDT -- would be represented as: 19940525133015.000000-300 ------------------------------------------------------------------------------- DellTimestamp ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Time Stamp." SYNTAX OCTET STRING (SIZE (26)) -- MIB Objects and Tables -------------------------------------------------------- dell OBJECT IDENTIFIER ::= { enterprises 674 } server3 OBJECT IDENTIFIER ::= { dell 10892 } dmmOutOfBandGroup OBJECT IDENTIFIER ::= { server3 6 } dmmInformationGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 1 } dmmProductInfoGroup OBJECT IDENTIFIER ::= { dmmInformationGroup 1 } dmmFirmwareGroup OBJECT IDENTIFIER ::= { dmmInformationGroup 2 } dmmStatusGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 2 } dmmChassisStatusGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 3 } dmmStatusNowGroup OBJECT IDENTIFIER ::= { dmmChassisStatusGroup 1 } dmmChassisPowerGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 4 } DmmPowerTableEntry ::= SEQUENCE { dmmPowerChassisIndex DellPowerIndexRange, dmmPowerIdlePower DellPowerReading, dmmPowerKWhCumulative DellPowerReading, dmmPowerKWhCumulativeTime DellTimestamp, dmmPowerWattsPeakUsage DellPowerReading, dmmPowerWattsPeakTime DellTimestamp, dmmPowerWattsMinUsage DellPowerReading, dmmPowerWattsMinTime DellTimestamp, dmmPowerWattsReading DellPowerReading } DmmPSUTableEntry ::= SEQUENCE { dmmPSUChassisIndex DellPowerIndexRange, dmmPSUIndex DellPSUIndexRange, dmmPSULocation DellString, dmmPSUState DellString, dmmPSUType DellString, dmmPSUCapacity DellPowerReading, dmmPSUVoltage DellPowerReading, dmmPSUCurrStatus DellStatus } dmmChassisAlert2Group OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 5 } dmmChassisAlert2Variables OBJECT IDENTIFIER ::= { dmmChassisAlert2Group 1 } dmmGenericAlertGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 6 } dmmGenericAlertVariables OBJECT IDENTIFIER ::= { dmmGenericAlertGroup 1 } conformanceGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 7 } conformanceMIBGroups OBJECT IDENTIFIER ::= { conformanceGroup 1 } conformanceMIBnotificationGroup OBJECT IDENTIFIER ::= { conformanceGroup 2 } -- Variables and Traps ------------------------------------------------------------------------ ------------------------------------------------------------------------------- -- group: product information ------------------------------------------------------------------------------- dmmProductInfoObjGroup OBJECT-GROUP OBJECTS { dmmProductName, dmmProductShortName, dmmProductDescription, dmmProductManufacturer, dmmProductVersion, dmmChassisServiceTag, dmmProductURL, dmmProductChassisAssetTag, dmmProductChassisName, dmmProductType, dmmProductChassisDataCenter, dmmProductChassisAisle, dmmProductChassisRack, dmmProductChassisRackSlot,dmmProductChassisModel, dmmProductChassisExpressServiceCode, dmmProductChassisSystemID } STATUS current DESCRIPTION "A collection of objects providing information about the chassis management module." ::= { conformanceMIBGroups 1 } dmmProductName OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the product name of a chassis management module." ::= { dmmProductInfoGroup 1 } dmmProductShortName OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the short product name of a chassis management module. " ::= { dmmProductInfoGroup 2 } dmmProductDescription OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the product description of a chassis management module. " ::= { dmmProductInfoGroup 3 } dmmProductManufacturer OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the product manufacturer of a chassis management module. " ::= { dmmProductInfoGroup 4 } dmmProductVersion OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the product version of a chassis management module. " ::= { dmmProductInfoGroup 5 } dmmChassisServiceTag OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the Service Tag of the chassis. " ::= { dmmProductInfoGroup 6 } dmmProductURL OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the out-of-band UI URL of a chassis management module. " ::= { dmmProductInfoGroup 7 } dmmProductChassisAssetTag OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the Asset Tag of the chassis. " ::= { dmmProductInfoGroup 8 } dmmProductChassisName OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the name of the chassis. " ::= { dmmProductInfoGroup 9 } dmmProductType OBJECT-TYPE SYNTAX DellMmType MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines type of a remote management module " ::= { dmmProductInfoGroup 10 } dmmProductChassisDataCenter OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the Data Center locator of the chassis. " ::= { dmmProductInfoGroup 11 } dmmProductChassisAisle OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the Aisle locator of the chassis. " ::= { dmmProductInfoGroup 12 } dmmProductChassisRack OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS current DESCRIPTION "This attribute defines the Rack locator of the chassis. " ::= { dmmProductInfoGroup 13 } dmmProductChassisRackSlot OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the Rack Slot locator of the chassis. " ::= { dmmProductInfoGroup 14 } dmmProductChassisModel OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the Model of the chassis." ::= { dmmProductInfoGroup 15 } dmmProductChassisExpressServiceCode OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the Express Service Code of the chassis." ::= { dmmProductInfoGroup 16 } dmmProductChassisSystemID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the System ID of the chassis." ::= { dmmProductInfoGroup 17 } ------------------------------------------------------------------------------- -- group: firmware ------------------------------------------------------------------------------- dmmFirmwareObjGroup OBJECT-GROUP OBJECTS { dmmFirmwareVersion, dmmFirmwareVersion2 } STATUS current DESCRIPTION "A collection of objects providing information about the chassis firmware version." ::= { conformanceMIBGroups 2 } dmmFirmwareVersion OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the firmware version of chassis management module 1." ::= { dmmFirmwareGroup 1 } dmmFirmwareVersion2 OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the firmware version of chassis management module 2." ::= { dmmFirmwareGroup 2 } ------------------------------------------------------------------------------- -- group: chassis status ------------------------------------------------------------------------------- dmmStatusObjGroup OBJECT-GROUP OBJECTS { dmmGlobalSystemStatus } STATUS current DESCRIPTION "Object is providing information about the overall chassis status." ::= { conformanceMIBGroups 3 } dmmGlobalSystemStatus OBJECT-TYPE SYNTAX DellStatus MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the overall chassis status being monitored by the chassis management module." ::= { dmmStatusGroup 1 } dmmStatusNowObjGroup OBJECT-GROUP OBJECTS { dmmIOMCurrStatus, dmmRedCurrStatus, dmmPowerCurrStatus, dmmFanCurrStatus, dmmBladeCurrStatus, dmmTempCurrStatus, dmmMMCurrStatus, dmmChassisFrontPanelAmbientTemperature } STATUS current DESCRIPTION "A collection of objects providing information about the chassis subsystem status." ::= { conformanceMIBGroups 4 } dmmIOMCurrStatus OBJECT-TYPE SYNTAX DellStatus MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the IOM subsystem status being monitored by the chassis management module." ::= { dmmStatusNowGroup 1 } dmmRedCurrStatus OBJECT-TYPE SYNTAX DellStatus MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the Redundancy status being monitored by the chassis management module." ::= { dmmStatusNowGroup 2 } dmmPowerCurrStatus OBJECT-TYPE SYNTAX DellStatus MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the power subsystem health status being monitored by the chassis management module." ::= { dmmStatusNowGroup 3 } dmmFanCurrStatus OBJECT-TYPE SYNTAX DellStatus MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the Fan subsystem health status being monitored by the chassis management module." ::= { dmmStatusNowGroup 4 } dmmBladeCurrStatus OBJECT-TYPE SYNTAX DellStatus MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the Blade subsystem health status being monitored by the chassis management module." ::= { dmmStatusNowGroup 5 } dmmTempCurrStatus OBJECT-TYPE SYNTAX DellStatus MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the Temp Sensor subsystem health status being monitored by the chassis management module." ::= { dmmStatusNowGroup 6 } dmmMMCurrStatus OBJECT-TYPE SYNTAX DellStatus MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the health status being monitored by the chassis management module." ::= { dmmStatusNowGroup 7 } dmmChassisFrontPanelAmbientTemperature OBJECT-TYPE SYNTAX DellTemperatureReading MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis front panel module." ::= { dmmStatusNowGroup 8 } ------------------------------------------------------------------------------- -- group: chassis power ------------------------------------------------------------------------------- dmmChassisPowerObjGroup OBJECT-GROUP OBJECTS { dmmPowerTable, dmmPSUTable } STATUS current DESCRIPTION "A collection of objects providing information about the chassis Power." ::= { conformanceMIBGroups 5 } dmmPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF DmmPowerTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object defines the power table." ::= { dmmChassisPowerGroup 1 } dmmPowerTableEntry OBJECT-TYPE SYNTAX DmmPowerTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object defines the power table entry." INDEX { dmmPowerChassisIndex } ::= { dmmPowerTable 1 } dmmPSUTable OBJECT-TYPE SYNTAX SEQUENCE OF DmmPSUTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object defines the PSU table." ::= { dmmChassisPowerGroup 2 } dmmPSUTableEntry OBJECT-TYPE SYNTAX DmmPSUTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object defines the PSU table entry." INDEX { dmmPSUChassisIndex, dmmPSUIndex } ::= { dmmPSUTable 1 } ------------------------------------------------------------------------------- -- table: power information ------------------------------------------------------------------------------- dmmPowerTableObjEntry OBJECT-GROUP OBJECTS { dmmPowerChassisIndex, dmmPowerIdlePower, dmmPowerKWhCumulative, dmmPowerKWhCumulativeTime, dmmPowerWattsPeakUsage, dmmPowerWattsPeakTime, dmmPowerWattsMinUsage, dmmPowerWattsMinTime, dmmPowerWattsReading } STATUS current DESCRIPTION "A collection of objects providing information about the chassis Power Information." ::= { conformanceMIBGroups 6 } dmmPowerChassisIndex OBJECT-TYPE SYNTAX DellPowerIndexRange MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the index (one-based) of the associated chassis." ::= { dmmPowerTableEntry 1 } dmmPowerIdlePower OBJECT-TYPE SYNTAX DellPowerReading MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the minimum power requirements for all currently powered-on servers." ::= { dmmPowerTableEntry 2 } dmmPowerKWhCumulative OBJECT-TYPE SYNTAX DellPowerReading MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the cumulative chassis power usage (in KWh) since last reset." ::= { dmmPowerTableEntry 3 } dmmPowerKWhCumulativeTime OBJECT-TYPE SYNTAX DellTimestamp MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the timestamp of the most recent chassis power accumulator reset." ::= { dmmPowerTableEntry 4 } dmmPowerWattsPeakUsage OBJECT-TYPE SYNTAX DellPowerReading MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the chassis peak power usage (in Watts) since last reset." ::= { dmmPowerTableEntry 5 } dmmPowerWattsPeakTime OBJECT-TYPE SYNTAX DellTimestamp MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the timestamp of the most recent chassis peak power usage." ::= { dmmPowerTableEntry 6 } dmmPowerWattsMinUsage OBJECT-TYPE SYNTAX DellPowerReading MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the chassis mimimum power usage (in Watts) since last reset." ::= { dmmPowerTableEntry 7 } dmmPowerWattsMinTime OBJECT-TYPE SYNTAX DellTimestamp MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the timestamp of the most recent chassis minimum power usage." ::= { dmmPowerTableEntry 8 } dmmPowerWattsReading OBJECT-TYPE SYNTAX DellPowerReading MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the instantaneous chassis power usage (in Watts)." ::= { dmmPowerTableEntry 9 } ------------------------------------------------------------------------------- -- table: PSU info ------------------------------------------------------------------------------- dmmPSUTableObjEntry OBJECT-GROUP OBJECTS { dmmPSUChassisIndex, dmmPSUIndex, dmmPSULocation, dmmPSUState, dmmPSUType, dmmPSUCapacity, dmmPSUVoltage, dmmPSUCurrStatus } STATUS current DESCRIPTION "A collection of objects providing information about the chassis Power Supply." ::= { conformanceMIBGroups 7 } dmmPSUChassisIndex OBJECT-TYPE SYNTAX DellPowerIndexRange MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the index (one-based) of the associated chassis." ::= { dmmPSUTableEntry 1 } dmmPSUIndex OBJECT-TYPE SYNTAX DellPSUIndexRange MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the index (one-based) of the associated PSU." ::= { dmmPSUTableEntry 2 } dmmPSULocation OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the location of the PSU." ::= { dmmPSUTableEntry 3 } dmmPSUState OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the enabled state of of the PSU." ::= { dmmPSUTableEntry 4 } dmmPSUType OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the type of the PSU." ::= { dmmPSUTableEntry 5 } dmmPSUCapacity OBJECT-TYPE SYNTAX DellPowerReading MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the capacity in watts of the PSU." ::= { dmmPSUTableEntry 6 } dmmPSUVoltage OBJECT-TYPE SYNTAX DellPowerReading MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the input voltage of the PSU." ::= { dmmPSUTableEntry 7 } dmmPSUCurrStatus OBJECT-TYPE SYNTAX DellStatus MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the current status of the PSU." ::= { dmmPSUTableEntry 8 } ------------------------------------------------------------------------------- -- group: Chassis Alerts 2 ------------------------------------------------------------------------------- dmmChassisAlert2VariablesObj OBJECT-GROUP OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD } STATUS current DESCRIPTION "A collection of objects providing information about the chassis Alerts." ::= { conformanceMIBGroups 8 } dmmCA2MessageID OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "Message ID of the alert." ::= { dmmChassisAlert2Variables 1 } dmmCA2Message OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "Message describing the alert." ::= { dmmChassisAlert2Variables 2 } dmmCA2MessageArgs OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "Concatenated set of strings representing any message arguments that were used to construct the alert message. Each message argument string is enclosed in double quotes, and there is a comma after the ending double quote of each message argument string, except the last one. Any double quotes found within a message argument string were preprocessed and changed to single quotes." ::= { dmmChassisAlert2Variables 3 } dmmCA2AlertStatus OBJECT-TYPE SYNTAX DellStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the alert." ::= { dmmChassisAlert2Variables 4 } dmmCA2FQDD OBJECT-TYPE SYNTAX DisplayString (SIZE (0..512)) MAX-ACCESS read-only STATUS current DESCRIPTION "Fully qualified device descriptor of device causing the alert." ::= { dmmChassisAlert2Variables 5 } ------------------------------------------------------------------------------- -- group: Generic Alerts ------------------------------------------------------------------------------- dmmGenericAlertVariablesObj OBJECT-GROUP OBJECTS { dmmDeviceServiceTag } STATUS current DESCRIPTION "A collection of objects providing information about the chassis Alerts." ::= { conformanceMIBGroups 9 } dmmDeviceServiceTag OBJECT-TYPE SYNTAX DellString MAX-ACCESS read-only STATUS current DESCRIPTION "Service tag of the device." ::= { dmmGenericAlertVariables 1 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Amperage Probe Traps -- -- Category: System/1 -- Subcategory: AMP/16 ------------------------------------------------------------------------------ dmmChassisAlert2NotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { alert2AmperageProbeNormal, alert2AmperageProbeWarning, alert2AmperageProbeFailure, alert2BatteryNormal, alert2BatteryWarning, alert2BatteryFailure, alert2CableFailure, alert2CMCWarning, alert2CMCFailure, alert2FanInformation, alert2FanWarning, alert2FanFailure, alert2HardwareConfigurationInformation, alert2HardwareConfigurationWarning, alert2HardwareConfigurationFailure, alert2IOVirtualizationInformation, alert2IOVirtualizationWarning, alert2IOVirtualizationFailure, alert2LinkStatusInformation, alert2LinkStatusWarning, alert2LinkStatusFailure, alert2PowerSupplyNormal, alert2PowerSupplyWarning, alert2PowerSupplyFailure, alert2PowerSupplyAbsent, alert2PowerUsageInformation, alert2PowerUsageWarning, alert2PowerUsageFailure, alert2RedundancyInformation, alert2RedundancyDegraded, alert2RedundancyLost, alert2SecurityInformation, alert2SecurityWarning, alert2SecurityFailure, alert2SystemEventLogInformation, alert2SystemEventLogWarning, alert2SystemEventLogFailure,alert2SoftwareConfigurationInformation, alert2SoftwareConfigurationWarning, alert2SoftwareConfigurationFailure, alert2TemperatureProbeNormal, alert2TemperatureProbeWarning, alert2TemperatureProbeFailure, alert2VoltageProbeNormal, alert2VoltageProbeWarning, alert2VoltageProbeFailure, alert2StorageBatteryInformation, alert2StorageBatteryWarning, alert2StorageBatteryFailure, alert2StorageControllerInformation, alert2StorageControllerWarning, alert2StorageControllerFailure, alert2StorageEnclosureInformation, alert2StorageEnclosureWarning, alert2StorageEnclosureFailure, alert2StorageFanInformation, alert2StorageFanWarning, alert2StorageFanFailure, alert2StoragePhysicalDiskInformation, alert2StoragePhysicalDiskWarning, alert2StoragePhysicalDiskFailure, alert2StoragePowerSupplyInformation, alert2StoragePowerSupplyWarning, alert2StoragePowerSupplyFailure, alert2StorageSecurityInformation, alert2StorageSecurityWarning, alert2StorageSecurityFailure, alert2StorageManagementInformation, alert2StorageManagementWarning, alert2StorageManagementFailure, alert2StorageTemperatureProbeInformation, alert2StorageTemperatureProbeWarning, alert2StorageTemperatureProbeFailure, alert2StorageVirtualDiskInformation, alert2StorageVirtualDiskWarning, alert2StorageVirtualDiskFailure, alert2SoftwareChangeUpdateWarning, alert2CMCAuditInformation, alert2CMCAuditWarning, alert2CMCAuditFailure, alert2IOVirtualizationAuditWarning, alert2LicenseInformation, alert2LicenseWarning, alert2LicenseFailure, alert2PCIDeviceAuditWarning, alert2PowerSupplyAuditWarning, alert2PowerSupplyAuditFailure, alert2PowerUsageAuditInformation, alert2PowerUsageAuditWarning, alert2PowerUsageAuditFailure, alert2SoftwareChangeAuditFailure, alert2IOVConfigurationInformation, alert2IOVConfigurationWarning, alert2PCIDeviceConfigurationInformation, alert2SWCConfigurationWarning, alert2SWCConfigurationFailure, alert2CMCTestTrap } STATUS current DESCRIPTION "The two notifications which an SNMPv2 entity is required to implement." ::= { conformanceMIBnotificationGroup 1 } alert2AmperageProbeNormal NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag } STATUS current DESCRIPTION "Current sensor reading is within range." --#TYPE "System: Amperage Normal" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 2179 } alert2AmperageProbeWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Current sensor has detected a warning value." --#TYPE "System: Amperage Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2178 } alert2AmperageProbeFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Current sensor has detected a failure value." --#TYPE "System: Amperage Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2177 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Battery Traps -- -- Category: System/1 -- Subcategory: BAT/22 ------------------------------------------------------------------------------ alert2BatteryNormal NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Battery state has returned to normal; or battery presence had been detected." --#TYPE "System: Battery Normal" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 2227 } alert2BatteryWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Battery is low." --#TYPE "System: Battery Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2226 } alert2BatteryFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Battery has failed or battery is absent." --#TYPE "System: Battery Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2225 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Cable Traps -- -- Category: System/1 -- Subcategory: CBL/43 ------------------------------------------------------------------------------ alert2CableFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Cable failure." --#TYPE "System: Cable Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2393 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Traps -- -- Category: System/1 -- Subcategory: MM/62 ------------------------------------------------------------------------------ alert2CMCWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Chassis Management Module detected a warning." --#TYPE "System: Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2546 } alert2CMCFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Chassis Management Module detected an error." --#TYPE "System: Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2545 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Fan Traps -- -- Category: System/1 -- Subcategory: FAN/13 ------------------------------------------------------------------------------ alert2FanInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Fan information." --#TYPE "System: Fan Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 2155 } alert2FanWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Fan warning." --#TYPE "System: Fan Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2154 } alert2FanFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Fan failure." --#TYPE "System: Fan Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2153 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Hardware Configuration Traps -- -- Category: System/1 -- Subcategory: HWC/35 ------------------------------------------------------------------------------ alert2HardwareConfigurationInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Hardware configuration information." --#TYPE "System: Hardware Configuration Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 2331 } alert2HardwareConfigurationWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Hardware configuration warning." --#TYPE "System: Hardware Configuration Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2330 } alert2HardwareConfigurationFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Hardware configuration failure or critical event." --#TYPE "System: Hardware Configuration Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2329 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: IO Virtualization Traps -- -- Category: System/1 -- Subcategory: IOV/63 ------------------------------------------------------------------------------ alert2IOVirtualizationInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "IO Virtualization information." --#TYPE "System: IO Virtualization Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 2555 } alert2IOVirtualizationWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "IO Virtualization warning." --#TYPE "System: IO Virtualization Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2554 } alert2IOVirtualizationFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "IO Virtualization failure or critical event." --#TYPE "System: IO Virtualization Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2553 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Link Status Traps -- -- Category: System/1 -- Subcategory: LNK/25 ------------------------------------------------------------------------------ alert2LinkStatusInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Link status information." --#TYPE "System: Link Status Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 2251 } alert2LinkStatusWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Link status warning." --#TYPE "System: Link Status Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2250 } alert2LinkStatusFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Link status failure or critical event." --#TYPE "System: Link Status Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2249 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Power Supply Traps -- -- Category: System/1 -- Subcategory: PSU/17 ------------------------------------------------------------------------------ alert2PowerSupplyNormal NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Power supply has returned to normal." --#TYPE "System: Power Supply Normal" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 2187 } alert2PowerSupplyWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Power supply has detected a warning." --#TYPE "System: Power Supply Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2186 } alert2PowerSupplyFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Power supply has detected a failure." --#TYPE "System: Power Supply Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2185 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Power Supply Absent Traps -- -- Category: System/1 -- Subcategory: PSUA/52 ------------------------------------------------------------------------------ alert2PowerSupplyAbsent NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Power supply is absent." --#TYPE "System: Power Supply Absent" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2465 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Power Usage Traps -- -- Category: System/1 -- Subcategory: PWR/28 ------------------------------------------------------------------------------ alert2PowerUsageInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Power usage information." --#TYPE "System: Power Usage Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 2275 } alert2PowerUsageWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Power usage warning." --#TYPE "System: Power Usage Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2274 } alert2PowerUsageFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Power usage failure." --#TYPE "System: Power Usage Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2273 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Redundancy Traps -- -- Category: System/1 -- Subcategory: RDU/53 ------------------------------------------------------------------------------ alert2RedundancyInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Redundancy information." --#TYPE "System: Redundancy Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 2475 } alert2RedundancyDegraded NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Redundancy is degraded." --#TYPE "System: Redundancy Degraded" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2474 } alert2RedundancyLost NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Redundancy is lost." --#TYPE "System: Redundancy Lost" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2473 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Security Event Traps -- -- Category: System/1 -- Subcategory: SEC/42 ------------------------------------------------------------------------------ alert2SecurityInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Security information." --#TYPE "System: Security Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 2387 } alert2SecurityWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Security warning." --#TYPE "System: Security Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 2386 } alert2SecurityFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Security failure or critical event." --#TYPE "System: Security Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 2385 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: System Event Log Traps -- -- Category: System/1 -- Subcategory: SEL/41 ------------------------------------------------------------------------------ alert2SystemEventLogInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "System Event Log information." --#TYPE "System: System Event Log Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 2379 } alert2SystemEventLogWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "System Event Log warning." --#TYPE "System: System Event Log Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2378 } alert2SystemEventLogFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "System Event Log failure or critical event." --#TYPE "System: System Event Log Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 2377 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Software Configuration Traps -- -- Category: System/1 -- Subcategory: SWC/36 ------------------------------------------------------------------------------ alert2SoftwareConfigurationInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Software configuration information." --#TYPE "System: Software Configuration Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 2339 } alert2SoftwareConfigurationWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Software configuration warning." --#TYPE "System: Software Configuration Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2338 } alert2SoftwareConfigurationFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Software configuration failure." --#TYPE "System: Software Configuration Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2337 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Temperature Probe Traps -- -- Category: System/1 -- Subcategory: TMP/14 ------------------------------------------------------------------------------ alert2TemperatureProbeNormal NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Temperature sensor value is within range." --#TYPE "System: Temperature Normal" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 2163 } alert2TemperatureProbeWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Temperature sensor has detected a warning value." --#TYPE "System: Temperature Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2162 } alert2TemperatureProbeFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Temperature sensor has detected a failure value." --#TYPE "System: Temperature Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2161 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Voltage Probe Traps -- -- Category: System/1 -- Subcategory: VLT/15 ------------------------------------------------------------------------------ alert2VoltageProbeNormal NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Voltage sensor reading is within range." --#TYPE "System: Voltage Normal" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 2171 } alert2VoltageProbeWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Voltage sensor has detected a warning value." --#TYPE "System: Voltage Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2170 } alert2VoltageProbeFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Voltage sensor has detected a failure value." --#TYPE "System: Voltage Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 2169 } ------------------------------------------------------------------------------- -- Chassis Alerts 2: Storage: Battery Traps -- -- Category: Storage/2 -- Subcategory: BAT/22 ------------------------------------------------------------------------------- alert2StorageBatteryInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Battery information." --#TYPE "Storage: Battery Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 4275 } alert2StorageBatteryWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Battery warning." --#TYPE "Storage: Battery Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 4274 } alert2StorageBatteryFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Battery failure." --#TYPE "Storage: Battery Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS current ::= { dmmChassisAlert2Group 0 4273 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Controller Traps -- -- Category: Storage/2 -- Subcategory: CTL/29 ------------------------------------------------------------------------------ alert2StorageControllerInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Controller information." --#TYPE "Storage: Controller Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 4331 } alert2StorageControllerWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Controller warning." --#TYPE "Storage: Controller Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 4330 } alert2StorageControllerFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Controller failure." --#TYPE "Storage: Controller Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS current ::= { dmmChassisAlert2Group 0 4329 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Enclosure Traps -- -- Category: Storage/2 -- Subcategory: ENC/30 ------------------------------------------------------------------------------ alert2StorageEnclosureInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Enclosure information." --#TYPE "Storage: Enclosure Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 4339 } alert2StorageEnclosureWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Enclosure warning." --#TYPE "Storage: Enclosure Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 4338 } alert2StorageEnclosureFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Enclosure failure." --#TYPE "Storage: Enclosure Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS current ::= { dmmChassisAlert2Group 0 4337 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Fan Traps -- -- Category: Storage/2 -- Subcategory: FAN/13 ------------------------------------------------------------------------------ alert2StorageFanInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Fan information." --#TYPE "Storage: Fan Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 4203 } alert2StorageFanWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Fan warning." --#TYPE "Storage: Fan Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 4202 } alert2StorageFanFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Fan failure." --#TYPE "Storage: Fan Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS current ::= { dmmChassisAlert2Group 0 4201 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Physical Disk Traps -- -- Category: Storage/2 -- Subcategory: PDR/31 ------------------------------------------------------------------------------ alert2StoragePhysicalDiskInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Physical disk information." --#TYPE "Storage: Physical Disk Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 4347 } alert2StoragePhysicalDiskWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Physical disk warning." --#TYPE "Storage: Physical Disk Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 4346 } alert2StoragePhysicalDiskFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Physical disk failure." --#TYPE "Storage: Physical Disk Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS current ::= { dmmChassisAlert2Group 0 4345 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Power Supply Traps -- -- Category: Storage/2 -- Subcategory: PSU/17 ------------------------------------------------------------------------------ alert2StoragePowerSupplyInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Power supply information." --#TYPE "Storage: Power Supply Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 4235 } alert2StoragePowerSupplyWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Power supply warning." --#TYPE "Storage: Power Supply Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 4234 } alert2StoragePowerSupplyFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Power supply failure." --#TYPE "Storage: Power Supply Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS current ::= { dmmChassisAlert2Group 0 4233 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Security Event Traps -- -- Category: Storage/2 -- Subcategory: SEC/42 ------------------------------------------------------------------------------ alert2StorageSecurityInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Security information." --#TYPE "Storage: Security Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 4435 } alert2StorageSecurityWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Security warning." --#TYPE "Storage: Security Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 4434 } alert2StorageSecurityFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Security failure or critical event." --#TYPE "Storage: Security Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 4433 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Storage Management Status Traps -- -- Category: Storage/2 -- Subcategory: STOR/10 ------------------------------------------------------------------------------ alert2StorageManagementInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Management information. There is no global status change associated with this trap." --#TYPE "Storage: Storage Management Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 4179 } alert2StorageManagementWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Management has detected a device independent warning condition. There is no global status change associated with this trap." --#TYPE "Storage: Storage Management Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 4178 } alert2StorageManagementFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Management has detected a device independent error condition. There is no global status change associated with this trap." --#TYPE "Storage: Storage Management Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS current ::= { dmmChassisAlert2Group 0 4177 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Temperature Probe Traps -- -- Category: Storage/2 -- Subcategory: TMP/14 ------------------------------------------------------------------------------ alert2StorageTemperatureProbeInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Temperature probe information." --#TYPE "Storage: Temperature Probe Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 4211 } alert2StorageTemperatureProbeWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Temperature probe warning." --#TYPE "Storage: Temperature Probe Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 4210 } alert2StorageTemperatureProbeFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Temperature probe failure." --#TYPE "Storage: Temperature Probe Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS current ::= { dmmChassisAlert2Group 0 4209 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Virtual Disk Traps -- -- Category: Storage/2 -- Subcategory: VDR/32 ------------------------------------------------------------------------------ alert2StorageVirtualDiskInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Virtual disk information." --#TYPE "Storage: Virtual Disk Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 4355 } alert2StorageVirtualDiskWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Virtual disk warning." --#TYPE "Storage: Virtual Disk Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 4354 } alert2StorageVirtualDiskFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Storage Virtual disk failure." --#TYPE "Storage: Virtual Disk Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS current ::= { dmmChassisAlert2Group 0 4353 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Updates: Software Change Traps -- -- Category: Updates/3 -- Subcategory: SWU/21 ------------------------------------------------------------------------------ alert2SoftwareChangeUpdateWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Software change update warning." --#TYPE "Updates: Software Change Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 6314 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: Traps -- -- Category: Audit/4 -- Subcategory: /62 ------------------------------------------------------------------------------ alert2CMCAuditInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Chassis Management Module audit information." --#TYPE "Audit: Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 8691 } alert2CMCAuditWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Chassis Management Module audit warning." --#TYPE "Audit: Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 8690 } alert2CMCAuditFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Chassis Management Module audit failure or critical event." --#TYPE "Audit: Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 8689 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: IO Virtualization Traps -- -- Category: Audit/4 -- Subcategory: IOV/63 ------------------------------------------------------------------------------ alert2IOVirtualizationAuditWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "IO Virtualization audit warning." --#TYPE "Audit: IO Virtualization Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 8698 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: License Traps -- -- Category: Audit/4 -- Subcategory: LIC/40 ------------------------------------------------------------------------------ alert2LicenseInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "License information." --#TYPE "Audit: License Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 8515 } alert2LicenseWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "License warning." --#TYPE "Audit: License Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 8514 } alert2LicenseFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "License failure." --#TYPE "Audit: License Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 8513 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: PCI Device Traps -- -- Category: Audit/4 -- Subcategory: PCI/46 ------------------------------------------------------------------------------ alert2PCIDeviceAuditWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "PCI device audit warning." --#TYPE "Audit: PCI Device Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 8562 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: Power Supply Traps -- -- Category: Audit/4 -- Subcategory: PSU/17 ------------------------------------------------------------------------------ alert2PowerSupplyAuditWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Power Supply audit warning." --#TYPE "Audit: Power Supply Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 8330 } alert2PowerSupplyAuditFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Power Supply audit failure or critical event." --#TYPE "Audit: Power Supply Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 8329 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: Power Usage Traps -- -- Category: Audit/4 -- Subcategory: PWR/28 ------------------------------------------------------------------------------ alert2PowerUsageAuditInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Power usage audit information." --#TYPE "Audit: Power Usage Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 8419 } alert2PowerUsageAuditWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Power usage audit warning." --#TYPE "Audit: Power Usage Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 8418 } alert2PowerUsageAuditFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Power usage audit failure or critical event." --#TYPE "Audit: Power Usage Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 8417 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: Software Change Traps -- -- Category: Audit/4 -- Subcategory: SWU/21 ------------------------------------------------------------------------------ alert2SoftwareChangeAuditFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Software change audit failure or critical event." --#TYPE "Audit: Software Change Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 8361 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Configuration: IO Virtualization Traps -- -- Category: Configuration/5 -- Subcategory: IOV/63 ------------------------------------------------------------------------------ alert2IOVConfigurationInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "IO Virtualization configuration information." --#TYPE "Configuration: IO Virtualization Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 10747 } alert2IOVConfigurationWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "IO Virtualization configuration warning." --#TYPE "Configuration: IO Virtualization Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 10746 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Configuration: PCI Device Traps -- -- Category: Configuration/5 -- Subcategory: PCI/46 ------------------------------------------------------------------------------ alert2PCIDeviceConfigurationInformation NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "PCI device configuration information." --#TYPE "Configuration: PCI Device Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 10611 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Configuration: Software Configuration Traps -- -- Category: Configuration/5 -- Subcategory: SWC/36 ------------------------------------------------------------------------------ alert2SWCConfigurationWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Software configuration warning." --#TYPE "Configuration: Software Configuration Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 10530 } alert2SWCConfigurationFailure NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Software configuration failure." --#TYPE "Configuration: Software Configuration Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS current ::= { dmmChassisAlert2Group 0 10529 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: Configuration: Test Traps -- -- Category: Configuration/5 -- Subcategory: TST/19 ------------------------------------------------------------------------------ alert2CMCTestTrap NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} STATUS current DESCRIPTION "Test trap generated in response to a user request." --#TYPE "Configuration: Test Trap" --#SEVERITY INFORMATIONAL --#SUMMARY "%s" --#ARGUMENTS {1} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmChassisAlert2Group 0 10395 } dmmGenericAlertNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { alertGenericCritical, alertGenericWarning, alertGenericNormal, alertGenericInformational, alertGenericTestTrapEvent } STATUS current DESCRIPTION "The two notifications which an SNMPv2 entity is required to implement." ::= { conformanceMIBnotificationGroup 2 } ------------------------------------------------------------------------------ -- Alert 1: Internal: Internal MM Traps -- -- Category: Internal/1 -- Subcategory: Internal/1 ------------------------------------------------------------------------------ alertGenericCritical NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmDeviceServiceTag } STATUS current DESCRIPTION "MM generic critical system alert." --#TYPE "Internal: MM System Alert" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d " --#ARGUMENTS {0, 1, 3} --#CATEGORY "Internal Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmGenericAlertGroup 0 100 } ------------------------------------------------------------------------------ -- MM Alert 2: Internal: Internal MM Traps -- -- Category: Internal/1 -- Subcategory: Internal/2 ------------------------------------------------------------------------------ alertGenericWarning NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmDeviceServiceTag } STATUS current DESCRIPTION "MM generic warning system alert." --#TYPE "Internal: MM System Alert" --#SEVERITY WARNING --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d " --#ARGUMENTS {0, 1, 3} --#CATEGORY "Internal Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmGenericAlertGroup 0 200 } ------------------------------------------------------------------------------ -- MM Alert 3: Internal: Internal MM Traps -- -- Category: Internal/1 -- Subcategory: Internal/3 ------------------------------------------------------------------------------ alertGenericNormal NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmDeviceServiceTag } STATUS current DESCRIPTION "MM generic normal system alert." --#TYPE "Internal: MM System Alert" --#SEVERITY NORMAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d " --#ARGUMENTS {0, 1, 3} --#CATEGORY "Internal Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmGenericAlertGroup 0 300 } ------------------------------------------------------------------------------ -- MM Alert 4: Internal: Internal MM Traps -- -- Category: Internal/1 -- Subcategory: Internal/4 ------------------------------------------------------------------------------ alertGenericInformational NOTIFICATION-TYPE OBJECTS { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmDeviceServiceTag } STATUS current DESCRIPTION "MM generic information system alert." --#TYPE "Internal: MM System Alert" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d " --#ARGUMENTS {0, 1, 3} --#CATEGORY "Internal Events" --#STATE OPERATIONAL --#STATUS current ::= { dmmGenericAlertGroup 0 400 } ------------------------------------------------------------------------------ -- MM Alert 5: Internal: Internal MM Traps -- -- Category: Internal/1 -- Subcategory: Internal/5 ------------------------------------------------------------------------------ alertGenericTestTrapEvent NOTIFICATION-TYPE OBJECTS { dmmCA2Message } STATUS current DESCRIPTION "MM Generated a test trap event in response to a user request." --#TYPE "Internal: Dell MM Test TRAP Event" --#SEVERITY INFORMATIONAL --#SUMMARY "%s" --#ARGUMENTS {0} --#CATEGORY "Status Events" ::= { dmmGenericAlertGroup 0 500 } END ------------------------------------------------------------------------------ -- End MIB ------------------------------------------------------------------------------