-- ***************************************************************** -- DLINKPRIME-TIME-MIB.mib : D-Link Time MIB -- -- Copyright (c) 2014 D-Link Corporation, all rights reserved. -- -- ***************************************************************** DLINKPRIME-TIME-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY,OBJECT-TYPE, IpAddress, Unsigned32 FROM SNMPv2-SMI OBJECT-GROUP,MODULE-COMPLIANCE FROM SNMPv2-CONF TEXTUAL-CONVENTION,DateAndTime, TruthValue,DisplayString, RowStatus FROM SNMPv2-TC InterfaceIndexOrZero FROM IF-MIB InetAddressType,InetAddress FROM INET-ADDRESS-MIB dlinkPrimeCommon FROM DLINK-ID-REC-MIB; dlinkPrimeTimeMIB MODULE-IDENTITY LAST-UPDATED "201404260000Z" ORGANIZATION "D-Link Corp." CONTACT-INFO " D-Link Corporation Postal: No. 289, Sinhu 3rd Rd., Neihu District, Taipei City 114, Taiwan, R.O.C Tel: +886-2-66000123 E-mail: tsd@dlink.com.tw " DESCRIPTION "This MIB module defines objects for Time and Simple Network Time Protocol (SNTP)." REVISION "201404260000Z" DESCRIPTION "This is the first version of the MIB file. " ::= { dlinkPrimeCommon 23 } DlinkTimeSummerTimeValue ::= TEXTUAL-CONVENTION DISPLAY-HINT "2d-1d-1d,1d:1d" STATUS current DESCRIPTION "Denotes Summer Time starts or ends time. This value is always interpreted within the context of a dpTimeSummerTimeAutoSwitchMode value. When dpTimeSummerTimeAutoSwitchMode is disable(1), this value is not meaningful. When dpTimeSummerTimeAutoSwitchMode is date(2), the format is defined as follows: octets contents range ------ -------- ----------- 1-2 year 2000..2037 3 date 1..31 4 month 1..12 where January = 1 December = 12 5 hour 0..23 6 minute 0..59 For example, the first Feb 2000 at 13:30pm should be given as 07 d0 01 02 0d 1e For the first May 2000 at 1:20am should be given as 07 d0 01 05 01 14 " SYNTAX OCTET STRING (SIZE (6)) -- ----------------------------------------------------------------------------- dpTimeMIBNotifications OBJECT IDENTIFIER ::= { dlinkPrimeTimeMIB 0 } dpTimeMIBObjects OBJECT IDENTIFIER ::= { dlinkPrimeTimeMIB 1 } dpTimeMIBConformance OBJECT IDENTIFIER ::= { dlinkPrimeTimeMIB 2 } -- ----------------------------------------------------------------------------- dpTimeGeneral OBJECT IDENTIFIER ::= { dpTimeMIBObjects 1 } dpTimeSntpEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the state of SNTP function. Setting this object to 'true' will enable SNTP function. " ::= { dpTimeGeneral 1 } dpTimeSntpPollInterval OBJECT-TYPE SYNTAX Unsigned32 (30..99999) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the interval for the SNTP client to synchronize its clock with server." DEFVAL { 720 } ::= { dpTimeGeneral 2 } -- ----------------------------------------------------------------------------- dpTimeClock OBJECT IDENTIFIER ::= { dpTimeMIBObjects 2 } dpTimeManagedClock OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-write STATUS current DESCRIPTION "Use the object to manually set the system clock." ::= { dpTimeClock 1 } dpTimeCurrentTimeSource OBJECT-TYPE SYNTAX INTEGER { sntp(1), noTimeSource(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The object indicates the clock source." ::= { dpTimeClock 2 } dpTimeCurrentTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the current system time. System time can be disciplined or adjusted by RTC, SNTP, or configured by user. " ::= { dpTimeClock 3 } -- ----------------------------------------------------------------------------- dpTimeSummerTime OBJECT IDENTIFIER ::= { dpTimeClock 4 } dpTimeSummerTimeAutoSwitchMode OBJECT-TYPE SYNTAX INTEGER { disable(1), date(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the mode of the system to automatically switch to Summer Time (Daylight Saving Time). disable(1) - The Daylight Saving Time feature is disabled. date(2) - The Daylight Saving Time feature is enabled. The Summer Time should start and end on the specified date of the specified month. " DEFVAL { disable } ::= { dpTimeSummerTime 1 } dpTimeSummerTimeTimeZone OBJECT-TYPE SYNTAX INTEGER (-779..839) MAX-ACCESS read-write STATUS current DESCRIPTION "Local time offset in minutes from GMT." ::= { dpTimeSummerTime 2 } dpTimeSummerTimeStart OBJECT-TYPE SYNTAX DlinkTimeSummerTimeValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates when the Summer Time starts. This value is always interpreted within the context of a dpTimeSummerTimeAutoSwitchMode value. " ::= { dpTimeSummerTime 3 } dpTimeSummerTimeEnd OBJECT-TYPE SYNTAX DlinkTimeSummerTimeValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates when the Summer Time ends. This value is always interpreted within the context of a dpTimeSummerTimeAutoSwitchMode value. " ::= { dpTimeSummerTime 4 } dpTimeSummerTimeOffset OBJECT-TYPE SYNTAX INTEGER (30|60|90|120) UNITS "Minutes" MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this object indicates number of minutes to add or to subtract during Summer Time. This object is not meaningful when dpTimeSummerTimeAutoSwitchMode object is 'disable'." DEFVAL { 60 } ::= { dpTimeSummerTime 5 } -- ----------------------------------------------------------------------------- dpTimeServer OBJECT IDENTIFIER ::= { dpTimeMIBObjects 3 } dpTimeSntpServerAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP address of the time server which provides the clock synchronization." ::= { dpTimeServer 1 } dpTimeSntpServerStratum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the SNTP server stratum." ::= { dpTimeServer 2 } dpTimeSntpServerVersion OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the SNTP server version." ::= { dpTimeServer 3 } dpTimeSntpServerLastReceive OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the elapsed time that the SNTP time has been synchronized. " ::= { dpTimeServer 4 } -- *************************************************************************** -- Conformance -- *************************************************************************** dpTimeCompliances OBJECT IDENTIFIER ::= { dpTimeMIBConformance 1 } dpTimeCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities which implement the DLINKPRIME-TIME-MIB." MODULE -- this module MANDATORY-GROUPS { dpTimeSysInfoGroup } GROUP dpTimeClockGroup DESCRIPTION "This group is conditionally mandatory and must be implemented by the agent only if system clock can be manually configured." GROUP dpTimeSntpGroup DESCRIPTION "This group is conditionally mandatory and must be implemented by the agent only if SNTP feature is supported." GROUP dpTimeSummerTimeCfgGroup DESCRIPTION "This group is conditionally mandatory and must be implemented by the agent only if Daylight Saving Time feature is supported. " ::= { dpTimeCompliances 1 } -- units of conformance dpTimeGroups OBJECT IDENTIFIER ::= { dpTimeMIBConformance 2 } dpTimeSysInfoGroup OBJECT-GROUP OBJECTS { dpTimeCurrentTimeSource, dpTimeCurrentTime } STATUS current DESCRIPTION "A collection of objects provides the information for system time." ::= { dpTimeGroups 1 } dpTimeClockGroup OBJECT-GROUP OBJECTS { dpTimeManagedClock } STATUS current DESCRIPTION "A collection of objects provides configuration for system time." ::= { dpTimeGroups 2 } dpTimeSntpGroup OBJECT-GROUP OBJECTS { dpTimeSntpEnabled, dpTimeSntpPollInterval, dpTimeSntpServerAddr, dpTimeSntpServerStratum, dpTimeSntpServerVersion, dpTimeSntpServerLastReceive } STATUS current DESCRIPTION "A collection of objects provides configuration for SNTP." ::= { dpTimeGroups 3 } dpTimeSummerTimeCfgGroup OBJECT-GROUP OBJECTS { dpTimeSummerTimeAutoSwitchMode, dpTimeSummerTimeTimeZone, dpTimeSummerTimeStart, dpTimeSummerTimeEnd, dpTimeSummerTimeOffset } STATUS current DESCRIPTION "A collection of objects provides configuration for Daylight Saving Time feature." ::= { dpTimeGroups 4 } END