CORIANT-GROOVE-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, enterprises, Counter64, Unsigned32 FROM SNMPv2-SMI -- http://www.ietf.org/rfc/rfc2578.txt TEXTUAL-CONVENTION, DateAndTime, DisplayString, TruthValue, RowStatus,RowPointer FROM SNMPv2-TC; -- http://www.ietf.org/rfc/rfc2579.txt groove MODULE-IDENTITY LAST-UPDATED "202206041006Z" ORGANIZATION "Coriant R&D" CONTACT-INFO "Contact Coriant Customer Service at http://www.coriant.com/services_support" DESCRIPTION "SNMP MIB for Groove G30 release 4.5.2" REVISION "202206041006Z" DESCRIPTION "Auto-build version at 202206041006Z" ::= { products 2 } AmplifierGainRangeType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { standard (1), low (2), high (3), notAvailable (4) } CoriantCommonOtnEncryStatusEnum ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX BITS { notAvailable (0), handshake (1), keyInitializing (2), keyInSync (3), unreachable (4), mismatch (5), connectFailed (6), disabled (7), encryptFail (8), encryptNormal (9), authenticationFailed (10), trafficSquelched (11) } CoriantCommonOtnKeySyncSession ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicate the associated session for the ODU channel to synchronize keys. " SYNTAX OCTET STRING CoriantCommonpmThresholdValue ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING (SIZE (1..32)) CoriantCommonpmUnitOfValue ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { notApplicable (0), dbm (1), microseconds (2), ps (3), psNm (4), db (5), seconds (6), packets (7), events (8), octets (9), bits (10), bitsS (11), blocks (12), times (13), percentage (14), bitRatio (15), mhz (16), celsius (17), frames (18), radsS (19) } CoriantFileSwTypesDeviceFwVersion ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING (SIZE (0..64)) CoriantFileSwTypesDeviceName ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING (SIZE (0..64)) CoriantFileSwTypesSwVersion ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING (SIZE (0..20)) CoriantFileSwTypesSwloadProduct ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING (SIZE (0..32)) CoriantFileSwTypesSwloadVendor ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING (SIZE (0..32)) CoriantFmtypesConditionType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { idp (1), rupDeg (2), rupFail (3), meaHwvm (4), mea (5), pwra (6), pwrb (7), rupMiss (8), sbanr (9), sdf (10), thermal (11), sdcardmiss (12), sdcardfail (13), mgmtrst (14), progflt (15), ntppu (16), linkdown (17), los (18), lol (19), lofOtu (20), lomOtu (21), timOtu (22), bdiOtu (23), bersdOtu (24), aisOtu (25), bersdOdu (26), lckOdu (27), ociOdu (28), aisOdu (29), bdiOdu (30), timOdu (31), plmOdu (32), loomfi (33), msim (34), loflom (35), csfOpu (36), losync (37), lf (38), rf (39), csfLosGfp (40), csfLosyncGfp (41), csfFdiGfp (42), csfRdiGfp (43), lofdGfp (44), plmGfp (45), lpbkfacility (46), lpbkfterm (47), contcom (48), latchOpen (49), lof (50), aisL (51), msAis (52), timR (53), rsTim (54), rfiL (55), msRfi (56), cabs (99), oog (100), connectFail (101), encryptFail (102), keyexFail (103), bdi (104), bdiO (105), autoshutoff (106), fibrconnMiss (107), bdiP (108), losMsa (109), protna (110), switchThres (111), losyncCd (112), updatePskFail (113), encTrafficSquelch (114), optpwrDiffHigh (115), ptFail (116), ptDeg (117), pskMismatch (118), voatc (119), spanDeg (120), loa (121), topoMism (122), fipsSelftestFail (123), losOpr (124), degOpr (125), horl (126), autoshutoffDis (127), olf (128), swMism (129), tSe (10001), tDropevents (10002), tOctets (10003), tPkts (10004), tBroadcastpkts (10005), tMulticastpkts (10006), tCrcalignerrors (10007), tUndersizepkts (10008), tOversizepkts (10009), tFragments (10010), tJabbers (10011), tPkts64octets (10012), tPkts65to127octets (10013), tPkts128to255octets (10014), tPkts256to511octets (10015), tPkts512to1023octets (10016), tPkts1024to1518octets (10017), tUtilHt (10018), tBeFec (10019), tUbeFec (10020), tBerFecHt (10021), tEbOtu (10022), tEsOtu (10023), tSesOtu (10024), tUasOtu (10025), tEbOdu (10026), tEsOdu (10027), tSesOdu (10028), tUasOdu (10029), tDelayOduHt (10030), tDelayOduLt (10031), tDgdHt (10032), tCdLt (10033), tCdHt (10034), tOsnrLt (10035), tLoss (10036), tOprHt (10037), tOprLt (10038), tQfactorLt (10039), tOptHt (10040), tOptLt (10041), tPdlHt (10042), tOftHt (10043), tOftLt (10044), tOfrHt (10045), tOfrLt (10046), tCvS (10047), tEsS (10048), tSesS (10049), tUasS (10050), tSefs (10051), tBbeRs (10052), tEsRs (10053), tSesRs (10054), tUasRs (10055), tOfs (10056), tOprLaneHt (10057), tOprLaneLt (10058), tOprTotalHt (10059), tOprTotalLt (10060), tOptLaneHt (10061), tOptLaneLt (10062), tOptTotalHt (10063), tOptTotalLt (10064), tLossTx (10065), tLossRx (10066), tPtfs (10067), tOrlHt (10068), tCvPcs (10069), tEsPcs (10070), tSesPcs (10071), tUasPcs (10072), tCbeFec (10073), tFeb (10074), tIae (10075), tBiae (10076), tBe (10077), tPktserr (10078), init (11001), swupgCompld (11002), swupgFail (11003), swupgRollback (11004), upgCompld (11005), upgFail (11006), intrusion (11007), userlock (11008), swupgIp (11009), ztcFail (11010), ztcComplete (11011), dbactFail (11012), inactive (11013), restart (11014), fstoprot (11015), fstowkg (11016), lockout (11017), mantoprot (11018), mantowkg (11019), noreq (11020), sdonprot (11021), sdonwkg (11022), sfonprot (11023), sfonwkg (11024), wkswpr (11025), prswwk (11026), wtr (11027), dnr (11028), authnFailed (11029), loginFailed (11030), candidatePskMismatch (11031), updatePskCompld (11032), candidatePskAuthenticated (11033), updatePskReqRcv (11034), pulloutTriggered (11035), fipsSelftestPassed (11036), fwCrash (11037), powerArrayQuiteArea (11038) } CoriantFmtypesEntityTypeFm ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { t10gbe (1), t40gbe (2), t100gbe (3), ochOs (4), otu4 (5), otuc2 (6), otuc3 (7), oduc2 (8), oduc3 (9), odu4 (10), odu3 (11), odu2e (12), odu2 (13), shelf (14), slot (15), port (16), fan (17), chm1 (18), chm2 (19), bfm (20), mgteth (21), ntppeer (22), db (23), sw (24), log (25), security (26), psu (27), cfp2 (28), qsfp (29), time (30), user (31), ztc (32), ppp (33), fc8g (34), fc16g (35), oduflex (36), otu2 (37), otu2e (38), oc192 (39), stm64 (40), oms (41), gopt (42), paoscofp2 (43), pabaofp2 (44), pairofp2 (45), palrofp2 (46), paerofp2 (47), bahofp2 (48), subslot (50), occ2 (51), omd96 (52), amplifier (53), omd48S (54), omd48O (55), chm1g (56), tdcmofp2 (57), bauofp2 (58), paulrofp2 (59), osc (60), ots (61), sfpplus (62), xtm2 (63), omd8b1ofp2 (64), omd8b2ofp2 (65), opsofp2 (66), ops (67), chm1lh (68), chm2lh (69), t10gwanSonet (70), t10gwanSdh (71), otdrofp2 (72), ocmofp2 (73), och (74), otuc6 (75), oduc6 (76), otuc5 (77), oduc5 (78), otuc4 (79), oduc4 (80), chm2t (81), opsptofp2 (82), frcu (83), cad8ofp2 (84), cad8eofp2 (85), omd64 (86), t400gbe (87), ws04sofp2 (88), cad16aofp2 (89), baxofp2 (90), nmc (91), t1gbe (92), oc48 (93), stm16 (94), utm2 (95), rd09sm (96), omd48e (97), otuc7 (99), oduc7 (100), otuc9 (101), oduc9 (102), otuc11 (103), oduc11 (104), odu0 (105), odu1 (106), dge2m2ofp2 (107), pbmtpp (108), cfp2Dco (109), subport (110), sfp (111), ipsec (112) } CoriantFmtypesServiceAffectFm ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION " SA: service affecting NSA: non-service affecting " SYNTAX INTEGER { sa (1), nsa (2) } CoriantFmtypesSeverityLevel ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION " alarm severity " SYNTAX INTEGER { notApplicable (0), critical (1), major (2), minor (3), notAlarmed (4), notReported (5), cleared (6) } CoriantPmtypesPmInstance ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX RowPointer CoriantPmtypesPmParameter ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { all (0), eb (1), es (2), ses (3), uas (4), delay (5), delayMax (6), delayMin (7), dgd (8), dgdMax (9), dgdMin (10), cd (11), cdMax (12), cdMin (13), osnr (14), osnrMax (15), osnrMin (16), qFactor (17), qFactorMax (18), qFactorMin (19), opr (20), oprMax (21), oprMin (22), loss (23), se (24), dropevents (25), octets (26), pkts (27), broadcastpkts (28), multicastpkts (29), crcalignerrors (30), undersizepkts (31), oversizepkts (32), fragments (33), jabbers (34), pkts64octets (35), pkts65to127octets (36), pkts128to255octets (37), pkts256to511octets (38), pkts512to1023octets (39), pkts1024to1518octets (40), utilization (41), utilizationMax (42), utilizationMin (43), beFec (44), ubeFec (45), berFec (46), berFecMax (47), berFecMin (48), opt (49), optMax (50), optMin (51), pdl (52), pdlMax (53), pdlMin (54), oft (55), oftMax (56), oftMin (57), ofr (58), ofrMax (59), ofrMin (60), bbe (61), ofs (65), cv (66), sefs (67), oprLaneHigh (68), oprLaneHighMax (69), oprLaneHighMin (70), oprLaneLow (71), oprLaneLowMax (72), oprLaneLowMin (73), oprTotal (74), oprTotalMax (75), oprTotalMin (76), optLaneHigh (77), optLaneHighMax (78), optLaneHighMin (79), optLaneLow (80), optLaneLowMax (81), optLaneLowMin (82), optTotal (83), optTotalMax (84), optTotalMin (85), tmodule (86), tinlet (87), toutlet (88), tmoduleMax (89), tmoduleMin (90), tinletMax (91), tinletMin (92), toutletMax (93), toutletMin (94), berPostFec (95), berPostFecMax (96), berPostFecMin (97), psd (98), psc (99), lossTx (100), lossRx (101), encryptionFailRx (102), ptfs (103), orl (104), orlMax (105), orlMin (106), orlAvg (107), delayAvg (108), dgdAvg (109), cdAvg (110), osnrAvg (111), qFactorAvg (112), oprAvg (113), optAvg (114), berFecAvg (115), berPostFecAvg (116), pdlAvg (117), oftAvg (118), ofrAvg (119), oprLaneHighAvg (120), oprLaneLowAvg (121), oprTotalAvg (122), optLaneHighAvg (123), optLaneLowAvg (124), optTotalAvg (125), tmoduleAvg (126), tinletAvg (127), toutletAvg (128), utilizationAvg (129), delayFrame (130), delayFrameMax (131), delayFrameMin (132), delayFrameAvg (133), cbeFec (134), feb (135), iae (136), biae (137), be (138), pktserr (139), bber (140), bberMax (141), bberMin (142), bberAvg (143), sesr (144), sesrMax (145), sesrMin (146), sesrAvg (147), sop (148), sopMax (149), sopMin (150), sopAvg (151) } CoriantPmtypesPmpType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { notApplicable (0), oduNendEgress (1), oduNendIngress (2), otuNendIngress (3), delayMeasurementOdu (4), coherentOpticalInterface (5), opticalPower (6), loss (7), ethernetNendIngress (8), ethernetNendEgress (9), fec (10), fcNendIngress (11), sonetSNendIngress (12), sdhRsNendIngress (13), sonetSNendEgress (14), sdhRsNendEgress (15), shelfTemperature (16), equipmentTemperature (17), opticalPowerLane (18), protectionSwitch (19), lossTxrx (20), opticalPowerIngress (21), opticalPowerEgress (22), oduEncryption (23), pilotTone (24), lossTx (25), returnLoss (26), pcsNendIngress (27), macNendIngress (28), macNendEgress (29), ethernetErrorIngress (30), ethernetErrorEgress (31), all (100) } CoriantPmtypesValidityType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { complete (1), partial (2), notAvailable (3) } CoriantRpcConfigurableLedTypes ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Types of LEDs that can be enabled/disabled by the user. " SYNTAX INTEGER { ledTest (1), locationLed (2) } CoriantTypesActualPsd ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL UNITS:nW/GHz" SYNTAX OCTET STRING CoriantTypesCardType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { fan (11), psu (12), chm1 (13), chm2 (14), xtm2 (16), chm1g (17), chm1lh (18), chm2lh (19), utm2 (20), occ2 (100), omd96 (101), paoscofp2 (102), pabaofp2 (103), pairofp2 (104), palrofp2 (105), paerofp2 (106), bahofp2 (107), omd48S (109), omd48O (110), tdcmofp2 (111), bauofp2 (112), paulrofp2 (113), omd8b1ofp2 (114), omd8b2ofp2 (115), opsofp2 (116), otdrofp2 (117), ocmofp2 (118), opsptofp2 (119), chm2t (120), frcu (121), cad8ofp2 (122), cad8eofp2 (123), omd64 (124), ws04sofp2 (125), cad16aofp2 (126), baxofp2 (127), rd09sm (128), omd48e (129), dge2m2ofp2 (130), pbmtpp (131), virSim (200) } CoriantTypesCreationscope ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { systemCreated (0), userCreated (1), systemCreatedForUser (2) } CoriantTypesDBPrecision1 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "dB for 0.1 precision UNITS:dB" SYNTAX OCTET STRING CoriantTypesDBPrecision3 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Power ratio in dB. UNITS:dB" SYNTAX OCTET STRING CoriantTypesDate ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The type of date show the mm/dd/year. The date type does not allow negative years " SYNTAX OCTET STRING (SIZE (0|10)) CoriantTypesDecimalFract1 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING CoriantTypesDecimalFract2 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING CoriantTypesDecimalFract3 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING CoriantTypesDuplexMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { na (0), full (1), half (2) } CoriantTypesEnableSwitch ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { enabled (1), disabled (2) } CoriantTypesEquipmentType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { empty (0), filled (1), reserved (2), unrecognized (3), notApplicable (4), fan (11), psu (12), chm1 (13), chm2 (14), bfm (15), xtm2 (16), chm1g (17), chm1lh (18), chm2lh (19), utm2 (20), qsfp (21), cfp2 (22), sfpplus (23), sfp (24), cfp2Dco (25), occ2 (100), omd96 (101), paoscofp2 (102), pabaofp2 (103), pairofp2 (104), palrofp2 (105), paerofp2 (106), bahofp2 (107), omd48S (109), omd48O (110), tdcmofp2 (111), bauofp2 (112), paulrofp2 (113), omd8b1ofp2 (114), omd8b2ofp2 (115), opsofp2 (116), otdrofp2 (117), ocmofp2 (118), opsptofp2 (119), chm2t (120), frcu (121), cad8ofp2 (122), cad8eofp2 (123), omd64 (124), ws04sofp2 (125), cad16aofp2 (126), baxofp2 (127), rd09sm (128), omd48e (129), dge2m2ofp2 (130), pbmtpp (131), virSim (200) } CoriantTypesEthFec ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { enabled (1), disabled (2), auto (3) } CoriantTypesEthernetRate ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL UNITS:Mbit/s" SYNTAX INTEGER { na (0), t10 (1), t100 (2), t1000 (3), maxRate (4) } CoriantTypesFilename ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "String representing a filename " SYNTAX OCTET STRING (SIZE (1..128)) CoriantTypesFlowControl ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { na (0), off (1), txRx (2), tx (3), rx (4) } CoriantTypesFreq ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Supported Frequency Range. UNITS:MHz" SYNTAX Unsigned32 (0|191250000..196111250) CoriantTypesFreqGeneric ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Supported generic Frequency Range. UNITS:MHz" SYNTAX Unsigned32 CoriantTypesFreqRoadm ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING CoriantTypesFtpPath ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Representation of a FTP/STPF/FTPS/SCP path 'ftp://user@hostname/directorypath/filename' or an HTTP URL 'http://domain.com/filename' " SYNTAX OCTET STRING (SIZE (1..1024)) CoriantTypesGridOffsetType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Channel frequency offset to standard grid. UNITS:MHz" SYNTAX INTEGER (-25000|0|25000) CoriantTypesGridType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { notApplicable (0), fixed50g96ch (1), fixed100g48ch (2), fixed75g64ch (3), flexible (4) } CoriantTypesManagementDirection ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { notApplicable (0), ingress (1), egress (2) } CoriantTypesManagementLocation ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { nearEnd (1), farEnd (2), notApplicable (3) } CoriantTypesManagementTimePeriod ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { notApplicable (0), t15min (1), t24h (2), all (4), t1min (5), t1h (6) } CoriantTypesNameIdentifier ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING (SIZE (1..32)) CoriantTypesNodeIdType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Globally unique identifer for a device. " SYNTAX OCTET STRING (SIZE (7..63)) CoriantTypesNumberList ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "List of numbers using ',' as separator and '..' to represent ranges. Examples: '12' , '1..4' , '1,5,10..12,20' " SYNTAX OCTET STRING (SIZE (0..255)) CoriantTypesOduType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { unused (0), odu0 (1), odu1 (2), odu2 (3), odu2e (4), odu3 (5), odu3e (6), odu4 (7), oduflex (8), oduc2 (9), oduc3 (10), oduc4 (11), oduc5 (12), oduc6 (13), oduc7 (14), oduc9 (16), oduc11 (18) } CoriantTypesOnOff ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { on (1), off (2) } CoriantTypesOpticalDB ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Optical Attribute value with Unit dB UNITS:dB" SYNTAX OCTET STRING CoriantTypesOpticalPower ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Optical Power value in dBm UNITS:dBm" SYNTAX OCTET STRING CoriantTypesOpticalPowerPrecision2 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Power value in dBm. UNITS:dBm" SYNTAX OCTET STRING CoriantTypesOtukFec ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { sdfec15 (1), sdfec25 (2), g709 (3), i4 (4), i7 (5), nofec (6), staircase7 (7), sdfec15nd (8), sdfec27nd (9), sdfec15nd2 (10), transparent (11), ufec7 (12) } CoriantTypesPassword ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Any ASCII values between 32 and 126 decimal " SYNTAX OCTET STRING (SIZE (1..128)) CoriantTypesPercentage ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL UNITS:%" SYNTAX Unsigned32 (0..100) CoriantTypesPercentagePrecision2 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL UNITS:%" SYNTAX OCTET STRING CoriantTypesPluggableComplianceCode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { unrecognized (0), t400gbaseAoc (1), t400gbaseDac (2), t400gbaseSr4 (3), t400gbaseDr4 (4), t400gbaseFr4 (5), t400gbaseLr4 (6), t400gbaseEr4 (7), t400gbaseSr8 (8), t400gbaseLr8 (9), t100gbaseAoc (10), t100gbaseSr4 (11), t100gbaseLr4 (12), t100gbaseEr4 (13), t100gbaseSr10 (14), t100gCwdm4 (15), t100gPsm4 (16), t100gbaseAcc (17), t100gbaseClr4 (18), t100gbaseCr4 (19), t100geDwdm2 (20), t25gbaseCrS (21), t25gbaseCrN (22), t40gbaseCr4 (23), t40gbaseSr4 (24), t40gbaseLr4 (25), t40gbaseAc (26), t40gbaseEr4 (27), t4x10gbaseSr (28), t4x10gbaseLr (29), t40gPsm4 (30), t10gbaseT (31), t10gbaseIr (32), t10gbaseSr (33), t10gbaseEr (34), t10gbaseZr (35), t10gbaseLr (36), t10gbaseLrm (37), t1000baseT (38), t1000baseCx (39), t1000baseLx (40), t1000baseSx (41), basePx (42), baseBx10 (43), t100baseFx (44), t100baseLxLx10 (45), p1i12d1 (46), p1s12d2 (47), p1l12d2 (48), t100gClr4 (49), t100gAoc (50), t100gAcc (51), t40gOtn (52), oc3Sr (53), oc3Sr1 (54), oc3Ir1 (55), oc3Ir2 (56), oc3Lr1 (57), oc3Lr2 (58), oc3Lr3 (59), oc12Sr (60), oc12Sr1 (61), oc12Ir1 (62), oc12Ir2 (63), oc12Lr1 (64), oc12Lr2 (65), oc12Lr3 (66), oc48Sr (67), oc48Sr1 (68), oc48Ir1 (69), oc48Ir2 (70), oc48Lr1 (71), oc48Lr2 (72), oc48Lr3 (73), oc48Lr (74), oc48Ir (75), oc192Sr (76), oc192Sr1 (77), fc16gV (78), fc16gS (79), fc16gI (80), fc16gL (81), fc16gM (82), fc12gV (83), fc12gS (84), fc12gI (85), fc12gL (86), fc12gM (87), fc8gV (88), fc8gS (89), fc8gI (90), fc8gL (91), fc8gM (92), fc4gV (93), fc4gS (94), fc4gI (95), fc4gL (96), fc4gM (97), fc2gV (98), fc2gS (99), fc2gI (100), fc2gL (101), fc2gM (102), fc1gV (103), fc1gS (104), fc1gI (105), fc1gL (106), fc1gM (107), t4xfc8g (108), t4xfc16g (109), t4xfc8gL (110), t4xfc16gL (111), t4xfc8gS (112), t4xfc16gS (113), flexirate200g (114), lc (300), copper (301), mpo12 (302) } CoriantTypesPluggableFormFactor ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicating the exact form factor of the pluggable. " SYNTAX INTEGER { notApplicable (0), unrecognized (1), qsfpplus (2), qsfp28 (3), cfp2Aco (4), sfpplus (5), sfp (6), xfp (7), qsfpDd (8), cfp2Dco (9) } CoriantTypesPluggableType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { nonPluggable (20), qsfp (21), cfp2 (22), sfpplus (23), sfp (24), cfp2Dco (25) } CoriantTypesPortId ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX Unsigned32 CoriantTypesPortMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { notApplicable (0), t10gbe (1), t40gbe (2), t100gbe (3), subport (4), qpsk100g (5), t8qam300g (6), t16qam200g (7), fc16g (8), fc8g (9), otu4 (10), otu2 (12), otu2e (13), oc192 (14), stm64 (15), ochosOtu2 (16), ochosOtu2e (17), t8qam200g (18), t10gwanSonet (19), t10gwanSdh (20), t64qam600g (21), t400gbe (22), spqpsk100g (23), spqpskQpsk100g (24), qpsk200g (25), sp16qam200g (26), t32qam200g (27), qpskSp16qam200g (28), t16qam300g (29), sp16qam300g (30), t32qam300g (31), t64qam300g (32), sp16qam16qam300g (33), t16qam400g (34), t32qam400g (35), t64qam400g (36), t16qam32qam400g (37), t32qam500g (38), t64qam500g (39), t32qam64qam500g (40), otu4Transparent (41), qpsk100gTransparent (42), sp16qam16qam200g (43), t32qam64qam600g (44), t1gbe (45), oc48 (46), stm16 (47), sp16qam300gC (48), qpskSp16qam300gC (49), t16qam32qam500gC (50), t16qam500gC (51), sp16qam500gC (52), qpskSp16qam500gC (53), t32qam64qam700gC (54), t16qam700gC (55), sp16qam16qam700gC (56), t32qam900gC (57), t16qam32qam900gC (58), t32qam64qam1100gC (59), spqpskQpsk200g (60), qpskSp16qam300g (61), sp16qam16qam400g (62), t16qam32qam500g (63) } CoriantTypesPower ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Power consumption value in W(WAT) UNITS:W" SYNTAX OCTET STRING CoriantTypesPsd ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL UNITS:nW/GHz" SYNTAX OCTET STRING CoriantTypesRtpType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type of the routing protocol. " SYNTAX INTEGER { direct (1), static (2), ospfv2 (3), ebgp (4) } CoriantTypesSessionId ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING (SIZE (0..45)) CoriantTypesShelfId ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX Unsigned32 (1..65535) CoriantTypesSlotId ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX Unsigned32 CoriantTypesSnmpString ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING (SIZE (1..32)) CoriantTypesSourceProtocol ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { direct (1), static (2), ospfv2 (3), bgp (4), ipcp (5) } CoriantTypesSubslotId ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX Unsigned32 CoriantTypesTemperature ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Temperature value in degree Celsius. UNITS:Celsius" SYNTAX OCTET STRING CoriantTypesTemperaturePrecision3 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Temperature value in Celsius with 0.001 precision UNITS:Celsius" SYNTAX OCTET STRING CoriantTypesTestSignalConfig ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { none (0), rxtx (3) } CoriantTypesTestSignalType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { none (0), prbs (1), idle (3) } CoriantTypesTimMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { none (0), sapi (1), dapi (2), oper (3), sapiDapi (4), sapiOper (5), dapiOper (6), sapiDapiOper (7) } CoriantTypesTimePeriod ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Representation of a time period in 'hh:mm:ss' " SYNTAX OCTET STRING (SIZE (8)) CoriantTypesTtiType15 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING (SIZE (0..15)) CoriantTypesTtiType32 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING (SIZE (0..32)) CoriantTypesTypeOfDirection ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { notApplicable (0), tx (2), rx (3), rxtx (4) } CoriantTypesUserName ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "According with Linux user-name pattern " SYNTAX OCTET STRING (SIZE (1..32)) CoriantTypesYesNo ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { yes (1), no (2) } HmoNetworkingBridgePortState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { discarding (0), blocked (1), learning (2), forwarding (3), unknown (4) } IanaAfnSafiAddressFamily ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This typedef is a YANG enumeration of IANA-registered address family numbers (AFN). " SYNTAX INTEGER { ipv4 (1), ipv6 (2), nsap (3), hdlc (4), bbn1822 (5), all802 (6), e163 (7), e164 (8), f69 (9), x121 (10), ipx (11), appletalk (12), decnetiv (13), banyanvines (14), e164withnsap (15), dns (16), distinguishedname (17), asnumber (18), xtpoveripv4 (19), xtpoveripv6 (20), xtpnativemodextp (21), fibrechannelwwpn (22), fibrechannelwwnn (23), gwid (24), l2vpn (25), mplstpsectionendpointidentifier (26), mplstplspendpointidentifier (27), mplstppseudowireendpointidentifier (28), eigrpcommonservicefamily (16384), eigrpipv4servicefamily (16385), eigrpipv6servicefamily (16386), lispcanonicaladdressformat (16387), bgpls (16388), t48bitmac (16389), t64bitmac (16390) } IanaAfnSafiSubsequentAddressFamily ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This typedef is a YANG enumeration of IANA-registered subsequent address family identifiers (SAFI). " SYNTAX INTEGER { nlriunicast (1), nlrimulticast (2), nlrimpls (4), mcastvpn (5), nlridynamicmspw (6), encapsulation (7), tunnel (64), vpls (65), bgpmdt (66), bgp4over6 (67), bgp6over4 (68), l1vpnautodiscovery (69), mplsvpn (128), multicastbgpmplsvpn (129), routetargetconstraints (132), ipv4dissflow (133), vpnv4dissflow (134), vpnautodiscovery (140), private241 (241), private242 (242), private243 (243), private244 (244), private245 (245), private246 (246), private247 (247), private248 (248), private249 (249), private250 (250), private251 (251), private252 (252), private253 (253), private254 (254) } IetfBgpTypesBgpCommunityRegexpType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type definition for communities specified as regular expression patterns " SYNTAX OCTET STRING IetfBgpTypesBgpExtCommunityType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type definition for extended community attributes " SYNTAX OCTET STRING IetfBgpTypesBgpOriginAttrType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type definition for standard BGP origin attribute " SYNTAX INTEGER { igp (0), egp (1), incomplete (2) } IetfBgpTypesBgpSessionDirection ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type to describe the direction of NLRI transmission " SYNTAX INTEGER { inbound (0), outbound (1) } IetfBgpTypesBgpStdCommunityType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type definition for standard community attributes " SYNTAX OCTET STRING IetfBgpTypesBgpWellKnownCommunityType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type definition for well-known IETF community attribute values " SYNTAX OCTET STRING IetfBgpTypesCommunityType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "type describing variations of community attributes: STANDARD: standard BGP community [rfc1997] EXTENDED: extended BGP community [rfc4360] BOTH: both standard and extended community " SYNTAX INTEGER { standard (0), extended (1), both (2), none (3) } IetfBgpTypesPeerType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "labels a peer or peer group as explicitly internal or external " SYNTAX INTEGER { internal (0), external (1) } IetfBgpTypesPercentage ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Integer indicating a percentage value " SYNTAX Unsigned32 (0..100) IetfBgpTypesRemovePrivateAsOption ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "set of options for configuring how private AS path numbers are removed from advertisements " SYNTAX OCTET STRING IetfBgpTypesRrClusterIdType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "union type for route reflector cluster ids: option 1: 4-byte number option 2: IP address " SYNTAX OCTET STRING IetfInetTypesAsNumber ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The as-number type represents autonomous system numbers which identify an Autonomous System (AS). An AS is a set of routers under a single technical administration, using an interior gateway protocol and common metrics to route packets within the AS, and using an exterior gateway protocol to route packets to other ASes. IANA maintains the AS number space and has delegated large parts to the regional registries. Autonomous system numbers were originally limited to 16 bits. BGP extensions have enlarged the autonomous system number space to 32 bits. This type therefore uses an uint32 base type without a range restriction in order to support a larger autonomous system number space. In the value set and its semantics, this type is equivalent to the InetAutonomousSystemNumber textual convention of the SMIv2. " SYNTAX Unsigned32 IetfInetTypesDomainName ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The domain-name type represents a DNS domain name. The name SHOULD be fully qualified whenever possible. Internet domain names are only loosely specified. Section 3.5 of RFC 1034 recommends a syntax (modified in Section 2.1 of RFC 1123). The pattern above is intended to allow for current practice in domain name use, and some possible future expansion. It is designed to hold various types of domain names, including names used for A or AAAA records (host names) and other records, such as SRV records. Note that Internet host names have a stricter syntax (described in RFC 952) than the DNS recommendations in RFCs 1034 and 1123, and that systems that want to store host names in schema nodes using the domain-name type are recommended to adhere to this stricter standard to ensure interoperability. The encoding of DNS names in the DNS protocol is limited to 255 characters. Since the encoding consists of labels prefixed by a length bytes and there is a trailing NULL byte, only 253 characters can appear in the textual dotted notation. The description clause of schema nodes using the domain-name type MUST describe when and how these names are resolved to IP addresses. Note that the resolution of a domain-name value may require to query multiple DNS records (e.g., A for IPv4 and AAAA for IPv6). The order of the resolution process and which DNS record takes precedence can either be defined explicitly or may depend on the configuration of the resolver. Domain-name values use the US-ASCII encoding. Their canonical format uses lowercase US-ASCII characters. Internationalized domain names MUST be A-labels as per RFC 5890. " SYNTAX OCTET STRING (SIZE (1..253)) IetfInetTypesDscp ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The dscp type represents a Differentiated Services Code Point that may be used for marking packets in a traffic stream. In the value set and its semantics, this type is equivalent to the Dscp textual convention of the SMIv2. " SYNTAX Unsigned32 (0..63) IetfInetTypesHost ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The host type represents either an IP address or a DNS domain name. " SYNTAX OCTET STRING IetfInetTypesIpAddress ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The ip-address type represents an IP address and is IP version neutral. The format of the textual representation implies the IP version. This type supports scoped addresses by allowing zone identifiers in the address format. " SYNTAX OCTET STRING IetfInetTypesIpAddressNoZone ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The ip-address-no-zone type represents an IP address and is IP version neutral. The format of the textual representation implies the IP version. This type does not support scoped addresses since it does not allow zone identifiers in the address format. " SYNTAX OCTET STRING IetfInetTypesIpPrefix ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The ip-prefix type represents an IP prefix and is IP version neutral. The format of the textual representations implies the IP version. " SYNTAX OCTET STRING IetfInetTypesIpVersion ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This value represents the version of the IP protocol. In the value set and its semantics, this type is equivalent to the InetVersion textual convention of the SMIv2. " SYNTAX INTEGER { unknown (0), ipv4 (1), ipv6 (2) } IetfInetTypesIpv4Address ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The ipv4-address type represents an IPv4 address in dotted-quad notation. The IPv4 address may include a zone index, separated by a % sign. The zone index is used to disambiguate identical address values. For link-local addresses, the zone index will typically be the interface index number or the name of an interface. If the zone index is not present, the default zone of the device will be used. The canonical format for the zone index is the numerical format " SYNTAX OCTET STRING IetfInetTypesIpv4AddressNoZone ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An IPv4 address without a zone index. This type, derived from ipv4-address, may be used in situations where the zone is known from the context and hence no zone index is needed. " SYNTAX OCTET STRING IetfInetTypesIpv4Prefix ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The ipv4-prefix type represents an IPv4 address prefix. The prefix length is given by the number following the slash character and must be less than or equal to 32. A prefix length value of n corresponds to an IP address mask that has n contiguous 1-bits from the most significant bit (MSB) and all other bits set to 0. The canonical format of an IPv4 prefix has all bits of the IPv4 address set to zero that are not part of the IPv4 prefix. " SYNTAX OCTET STRING IetfInetTypesIpv6Address ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The ipv6-address type represents an IPv6 address in full, mixed, shortened, and shortened-mixed notation. The IPv6 address may include a zone index, separated by a % sign. The zone index is used to disambiguate identical address values. For link-local addresses, the zone index will typically be the interface index number or the name of an interface. If the zone index is not present, the default zone of the device will be used. The canonical format of IPv6 addresses uses the textual representation defined in Section 4 of RFC 5952. The canonical format for the zone index is the numerical format as described in Section 11.2 of RFC 4007. " SYNTAX OCTET STRING IetfInetTypesIpv6AddressNoZone ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An IPv6 address without a zone index. This type, derived from ipv6-address, may be used in situations where the zone is known from the context and hence no zone index is needed. " SYNTAX OCTET STRING IetfInetTypesIpv6FlowLabel ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The ipv6-flow-label type represents the flow identifier or Flow Label in an IPv6 packet header that may be used to discriminate traffic flows. In the value set and its semantics, this type is equivalent to the IPv6FlowLabel textual convention of the SMIv2. " SYNTAX Unsigned32 (0..1048575) IetfInetTypesIpv6Prefix ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The ipv6-prefix type represents an IPv6 address prefix. The prefix length is given by the number following the slash character and must be less than or equal to 128. A prefix length value of n corresponds to an IP address mask that has n contiguous 1-bits from the most significant bit (MSB) and all other bits set to 0. The IPv6 address should have all bits that do not belong to the prefix set to zero. The canonical format of an IPv6 prefix has all bits of the IPv6 address set to zero that are not part of the IPv6 prefix. Furthermore, the IPv6 address is represented as defined in Section 4 of RFC 5952. " SYNTAX OCTET STRING IetfInetTypesPortNumber ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The port-number type represents a 16-bit port number of an Internet transport-layer protocol such as UDP, TCP, DCCP, or SCTP. Port numbers are assigned by IANA. A current list of all assignments is available from . Note that the port number value zero is reserved by IANA. In situations where the value zero does not make sense, it can be excluded by subtyping the port-number type. In the value set and its semantics, this type is equivalent to the InetPortNumber textual convention of the SMIv2. " SYNTAX Unsigned32 (0..65535) IetfInetTypesUri ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The uri type represents a Uniform Resource Identifier (URI) as defined by STD 66. Objects using the uri type MUST be in US-ASCII encoding, and MUST be normalized as described by RFC 3986 Sections 6.2.1, 6.2.2.1, and 6.2.2.2. All unnecessary percent-encoding is removed, and all case-insensitive characters are set to lowercase except for hexadecimal digits, which are normalized to uppercase as described in Section 6.2.2.1. The purpose of this normalization is to help provide unique URIs. Note that this normalization is not sufficient to provide uniqueness. Two URIs that are textually distinct after this normalization may still be equivalent. Objects using the uri type may restrict the schemes that they permit. For example, 'data:' and 'urn:' schemes might not be appropriate. A zero-length URI is not a valid URI. This can be used to express 'URI absent' where required. In the value set and its semantics, this type is equivalent to the Uri SMIv2 textual convention defined in RFC 5017. " SYNTAX OCTET STRING IetfInterfacesInterfaceRef ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This type is used by data models that need to reference configured interfaces. " SYNTAX OCTET STRING IetfInterfacesInterfaceStateRef ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This type is used by data models that need to reference the operationally present interfaces. " SYNTAX OCTET STRING IetfNetconfAcmAccessOperationsType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NETCONF Access Operation. " SYNTAX BITS { create (0), read (1), update (2), delete (3), exec (4) } IetfNetconfAcmActionType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Action taken by the server when a particular rule matches. " SYNTAX INTEGER { permit (0), deny (1) } IetfNetconfAcmGroupNameType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Name of administrative group to which users can be assigned. " SYNTAX OCTET STRING (SIZE (1..65535)) IetfNetconfAcmMatchallStringType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The string containing a single asterisk '*' is used to conceptually represent all possible values for the particular leaf using this data type. " SYNTAX OCTET STRING IetfNetconfAcmNodeInstanceIdentifier ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Path expression used to represent a special data node instance identifier string. A node-instance-identifier value is an unrestricted YANG instance-identifier expression. All the same rules as an instance-identifier apply except predicates for keys are optional. If a key predicate is missing, then the node-instance-identifier represents all possible server instances for that key. This XPath expression is evaluated in the following context: o The set of namespace declarations are those in scope on the leaf element where this type is used. o The set of variable bindings contains one variable, 'USER', which contains the name of the user of the current session. o The function library is the core function library, but note that due to the syntax restrictions of an instance-identifier, no functions are allowed. o The context node is the root node in the data tree. " SYNTAX OCTET STRING IetfNetconfAcmUserNameType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "General Purpose Username string. " SYNTAX OCTET STRING (SIZE (1..65535)) IetfNetconfEditOperationType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NETCONF 'operation' attribute values " SYNTAX INTEGER { merge (0), replace (1), create (2), delete (3), remove (4) } IetfNetconfErrorSeverityType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NETCONF Error Severity " SYNTAX INTEGER { error (0), warning (1) } IetfNetconfErrorTagType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NETCONF Error Tag " SYNTAX INTEGER { inUse (0), invalidValue (1), tooBig (2), missingAttribute (3), badAttribute (4), unknownAttribute (5), missingElement (6), badElement (7), unknownElement (8), unknownNamespace (9), accessDenied (10), lockDenied (11), resourceDenied (12), rollbackFailed (13), dataExists (14), dataMissing (15), operationNotSupported (16), operationFailed (17), partialOperation (18), malformedMessage (19) } IetfNetconfSessionIdOrZeroType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NETCONF Session Id or Zero to indicate none " SYNTAX Unsigned32 IetfNetconfSessionIdType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NETCONF Session Id " SYNTAX Unsigned32 (1..4294967295) IetfNetconfWithDefaultsWithDefaultsMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Possible modes to report default data. " SYNTAX INTEGER { reportAll (0), reportAllTagged (1), trim (2), explicit (3) } IetfYangTypesCounter32 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The counter32 type represents a non-negative integer that monotonically increases until it reaches a maximum value of 2^32-1 (4294967295 decimal), when it wraps around and starts increasing again from zero. Counters have no defined 'initial' value, and thus, a single value of a counter has (in general) no information content. Discontinuities in the monotonically increasing value normally occur at re-initialization of the management system, and at other times as specified in the description of a schema node using this type. If such other times can occur, for example, the creation of a schema node of type counter32 at times other than re-initialization, then a corresponding schema node should be defined, with an appropriate type, to indicate the last discontinuity. The counter32 type should not be used for configuration schema nodes. A default statement SHOULD NOT be used in combination with the type counter32. In the value set and its semantics, this type is equivalent to the Counter32 type of the SMIv2. " SYNTAX Unsigned32 IetfYangTypesCounter64 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The counter64 type represents a non-negative integer that monotonically increases until it reaches a maximum value of 2^64-1 (18446744073709551615 decimal), when it wraps around and starts increasing again from zero. Counters have no defined 'initial' value, and thus, a single value of a counter has (in general) no information content. Discontinuities in the monotonically increasing value normally occur at re-initialization of the management system, and at other times as specified in the description of a schema node using this type. If such other times can occur, for example, the creation of a schema node of type counter64 at times other than re-initialization, then a corresponding schema node should be defined, with an appropriate type, to indicate the last discontinuity. The counter64 type should not be used for configuration schema nodes. A default statement SHOULD NOT be used in combination with the type counter64. In the value set and its semantics, this type is equivalent to the Counter64 type of the SMIv2. " SYNTAX OCTET STRING IetfYangTypesDateAndTime ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The date-and-time type is a profile of the ISO 8601 standard for representation of dates and times using the Gregorian calendar. The profile is defined by the date-time production in Section 5.6 of RFC 3339. The date-and-time type is compatible with the dateTime XML schema type with the following notable exceptions: (a) The date-and-time type does not allow negative years. (b) The date-and-time time-offset -00:00 indicates an unknown time zone (see RFC 3339) while -00:00 and +00:00 and Z all represent the same time zone in dateTime. (c) The canonical format (see below) of data-and-time values differs from the canonical format used by the dateTime XML schema type, which requires all times to be in UTC using the time-offset 'Z'. This type is not equivalent to the DateAndTime textual convention of the SMIv2 since RFC 3339 uses a different separator between full-date and full-time and provides higher resolution of time-secfrac. The canonical format for date-and-time values with a known time zone uses a numeric time zone offset that is calculated using the device's configured known offset to UTC time. A change of the device's offset to UTC time will cause date-and-time values to change accordingly. Such changes might happen periodically in case a server follows automatically daylight saving time (DST) time zone offset changes. The canonical format for date-and-time values with an unknown time zone (usually referring to the notion of local time) uses the time-offset -00:00. " SYNTAX OCTET STRING IetfYangTypesDottedQuad ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An unsigned 32-bit number expressed in the dotted-quad notation, i.e., four octets written as decimal numbers and separated with the '.' (full stop) character. " SYNTAX OCTET STRING IetfYangTypesGauge32 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The gauge32 type represents a non-negative integer, which may increase or decrease, but shall never exceed a maximum value, nor fall below a minimum value. The maximum value cannot be greater than 2^32-1 (4294967295 decimal), and the minimum value cannot be smaller than 0. The value of a gauge32 has its maximum value whenever the information being modeled is greater than or equal to its maximum value, and has its minimum value whenever the information being modeled is smaller than or equal to its minimum value. If the information being modeled subsequently decreases below (increases above) the maximum (minimum) value, the gauge32 also decreases (increases). In the value set and its semantics, this type is equivalent to the Gauge32 type of the SMIv2. " SYNTAX Unsigned32 IetfYangTypesGauge64 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The gauge64 type represents a non-negative integer, which may increase or decrease, but shall never exceed a maximum value, nor fall below a minimum value. The maximum value cannot be greater than 2^64-1 (18446744073709551615), and the minimum value cannot be smaller than 0. The value of a gauge64 has its maximum value whenever the information being modeled is greater than or equal to its maximum value, and has its minimum value whenever the information being modeled is smaller than or equal to its minimum value. If the information being modeled subsequently decreases below (increases above) the maximum (minimum) value, the gauge64 also decreases (increases). In the value set and its semantics, this type is equivalent to the CounterBasedGauge64 SMIv2 textual convention defined in RFC 2856 " SYNTAX OCTET STRING IetfYangTypesHexString ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A hexadecimal string with octets represented as hex digits separated by colons. The canonical representation uses lowercase characters. " SYNTAX OCTET STRING IetfYangTypesMacAddress ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The mac-address type represents an IEEE 802 MAC address. The canonical representation uses lowercase characters. In the value set and its semantics, this type is equivalent to the MacAddress textual convention of the SMIv2. " SYNTAX OCTET STRING IetfYangTypesObjectIdentifier ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The object-identifier type represents administratively assigned names in a registration-hierarchical-name tree. Values of this type are denoted as a sequence of numerical non-negative sub-identifier values. Each sub-identifier value MUST NOT exceed 2^32-1 (4294967295). Sub-identifiers are separated by single dots and without any intermediate whitespace. The ASN.1 standard restricts the value space of the first sub-identifier to 0, 1, or 2. Furthermore, the value space of the second sub-identifier is restricted to the range 0 to 39 if the first sub-identifier is 0 or 1. Finally, the ASN.1 standard requires that an object identifier has always at least two sub-identifiers. The pattern captures these restrictions. Although the number of sub-identifiers is not limited, module designers should realize that there may be implementations that stick with the SMIv2 limit of 128 sub-identifiers. This type is a superset of the SMIv2 OBJECT IDENTIFIER type since it is not restricted to 128 sub-identifiers. Hence, this type SHOULD NOT be used to represent the SMIv2 OBJECT IDENTIFIER type; the object-identifier-128 type SHOULD be used instead. " SYNTAX OCTET STRING IetfYangTypesObjectIdentifier128 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This type represents object-identifiers restricted to 128 sub-identifiers. In the value set and its semantics, this type is equivalent to the OBJECT IDENTIFIER type of the SMIv2. " SYNTAX OCTET STRING IetfYangTypesPhysAddress ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents media- or physical-level addresses represented as a sequence octets, each octet represented by two hexadecimal numbers. Octets are separated by colons. The canonical representation uses lowercase characters. In the value set and its semantics, this type is equivalent to the PhysAddress textual convention of the SMIv2. " SYNTAX OCTET STRING IetfYangTypesTimestamp ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The timestamp type represents the value of an associated timeticks schema node at which a specific occurrence happened. The specific occurrence must be defined in the description of any schema node defined using this type. When the specific occurrence occurred prior to the last time the associated timeticks attribute was zero, then the timestamp value is zero. Note that this requires all timestamp values to be reset to zero when the value of the associated timeticks attribute reaches 497+ days and wraps around to zero. The associated timeticks schema node must be specified in the description of any schema node using this type. In the value set and its semantics, this type is equivalent to the TimeStamp textual convention of the SMIv2. " SYNTAX Unsigned32 IetfYangTypesTimeticks ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The timeticks type represents a non-negative integer that represents the time, modulo 2^32 (4294967296 decimal), in hundredths of a second between two epochs. When a schema node is defined that uses this type, the description of the schema node identifies both of the reference epochs. In the value set and its semantics, this type is equivalent to the TimeTicks type of the SMIv2. " SYNTAX Unsigned32 IetfYangTypesUuid ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A Universally Unique IDentifier in the string representation defined in RFC 4122. The canonical representation uses lowercase characters. The following is an example of a UUID in string representation: f81d4fae-7dec-11d0-a765-00a0c91e6bf6 " SYNTAX OCTET STRING IetfYangTypesXpath10 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This type represents an XPATH 1.0 expression. When a schema node is defined that uses this type, the description of the schema node MUST specify the XPath context in which the XPath expression is evaluated. " SYNTAX OCTET STRING IetfYangTypesYangIdentifier ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A YANG identifier string as defined by the 'identifier' rule in Section 12 of RFC 6020. An identifier must start with an alphabetic character or an underscore followed by an arbitrary sequence of alphabetic or numeric characters, underscores, hyphens, or dots. A YANG identifier MUST NOT start with any possible combination of the lowercase or uppercase character sequence 'xml'. " SYNTAX OCTET STRING (SIZE (1..65535)) IetfYangTypesZeroBasedCounter32 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The zero-based-counter32 type represents a counter32 that has the defined 'initial' value zero. A schema node of this type will be set to zero (0) on creation and will thereafter increase monotonically until it reaches a maximum value of 2^32-1 (4294967295 decimal), when it wraps around and starts increasing again from zero. Provided that an application discovers a new schema node of this type within the minimum time to wrap, it can use the 'initial' value as a delta. It is important for a management station to be aware of this minimum time and the actual time between polls, and to discard data if the actual time is too long or there is no defined minimum time. In the value set and its semantics, this type is equivalent to the ZeroBasedCounter32 textual convention of the SMIv2. " SYNTAX Unsigned32 IetfYangTypesZeroBasedCounter64 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The zero-based-counter64 type represents a counter64 that has the defined 'initial' value zero. A schema node of this type will be set to zero (0) on creation and will thereafter increase monotonically until it reaches a maximum value of 2^64-1 (18446744073709551615 decimal), when it wraps around and starts increasing again from zero. Provided that an application discovers a new schema node of this type within the minimum time to wrap, it can use the 'initial' value as a delta. It is important for a management station to be aware of this minimum time and the actual time between polls, and to discard data if the actual time is too long or there is no defined minimum time. In the value set and its semantics, this type is equivalent to the ZeroBasedCounter64 textual convention of the SMIv2. " SYNTAX OCTET STRING IpsecDhGroup ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "DH groups for IKE and IPsec SA rekey. " SYNTAX Unsigned32 (14..21) IpsecEncryptionAlgorithmType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The encryption algorithm for IKEv2 and ESP. The first part of the encryption algorithm type is Encryption Algorithm Transform IDs of IKEv2 and the second part is the key length. e.g., AES_GCM_16_256 means ENCR_AES_GCM_16 with 256-bits key length. " SYNTAX INTEGER { aesCbc128 (1), aesCbc192 (2), aesCbc256 (3), aesCtr128 (4), aesCtr192 (5), aesCtr256 (6), aesGcm16128 (7), aesGcm16192 (8), aesGcm16256 (9) } IpsecIntegrityAlgorithmType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The integrity algorithm for IPsec and IKEv2. " SYNTAX INTEGER { sha2256 (1), sha2384 (2), sha2512 (3) } IpsecIpsecInnerProtocol ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "IPsec protection can be applied to specific IP traffic and layer 4 traffic (TCP, UDP, SCTP, etc.) or ANY protocol in the IP packet payload. We specify the IP protocol number with an uint8 or ANY defining an enumerate with value 256 to indicate the protocol number. " SYNTAX OCTET STRING KeySyncSessionCertificateRef ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "certificate to be referred to. " SYNTAX OCTET STRING KeySyncSessionInterfaceRef ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Interface to be referred to. " SYNTAX OCTET STRING LldpLldpSysCap ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX BITS { other (0), repeater (1), bridge (2), wlanaccesspoint (3), router (4), telephone (5), docsiscabledevice (6), stationonly (7), cvlancomponent (8), svlancomponent (9), twoportmacrelay (10) } NmcNmcPsd ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING OpenconfigAaaTypesCryptPasswordType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A password that is hashed based on the hash algorithm indicated by the prefix in the string. The string takes the following form, based on the Unix crypt function: $[$=(,=)*][$[$]] Common hash functions include: id | hash function ---+--------------- 1 | MD5 2a| Blowfish 2y| Blowfish (correct handling of 8-bit chars) 5 | SHA-256 6 | SHA-512 These may not all be supported by a target device. " SYNTAX OCTET STRING OpenconfigIfAggregateAggregationType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type to define the lag-type, i.e., how the LAG is defined and managed " SYNTAX INTEGER { lacp (0), static (1) } OpenconfigIfIpIpAddressOrigin ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The origin of an address. " SYNTAX INTEGER { other (0), static (1), dhcp (2), linkLayer (3), random (4) } OpenconfigIfIpNeighborOrigin ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The origin of a neighbor entry. " SYNTAX INTEGER { other (0), static (1), dynamic (2) } OpenconfigInetTypesAsNumber ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A numeric identifier for an autonomous system (AS). An AS is a single domain, under common administrative control, which forms a unit of routing policy. Autonomous systems can be assigned a 2-byte identifier, or a 4-byte identifier which may have public or private scope. Private ASNs are assigned from dedicated ranges. Public ASNs are assigned from ranges allocated by IANA to the regional internet registries (RIRs). " SYNTAX Unsigned32 OpenconfigInetTypesDomainName ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The domain-name type represents a DNS domain name. Fully quallified left to the models which utilize this type. Internet domain names are only loosely specified. Section 3.5 of RFC 1034 recommends a syntax (modified in Section 2.1 of RFC 1123). The pattern above is intended to allow for current practice in domain name use, and some possible future expansion. It is designed to hold various types of domain names, including names used for A or AAAA records (host names) and other records, such as SRV records. Note that Internet host names have a stricter syntax (described in RFC 952) than the DNS recommendations in RFCs 1034 and 1123, and that systems that want to store host names in schema nodes using the domain-name type are recommended to adhere to this stricter standard to ensure interoperability. The encoding of DNS names in the DNS protocol is limited to 255 characters. Since the encoding consists of labels prefixed by a length bytes and there is a trailing NULL byte, only 253 characters can appear in the textual dotted notation. Domain-name values use the US-ASCII encoding. Their canonical format uses lowercase US-ASCII characters. Internationalized domain names MUST be encoded in punycode as described in RFC 3492 " SYNTAX OCTET STRING (SIZE (1..253)) OpenconfigInetTypesDscp ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A differentiated services code point (DSCP) marking within the IP header. " SYNTAX Unsigned32 (0..63) OpenconfigInetTypesHost ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The host type represents either an unzoned IP address or a DNS domain name. " SYNTAX OCTET STRING OpenconfigInetTypesIpAddress ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An IPv4 or IPv6 address with no prefix specified. " SYNTAX OCTET STRING OpenconfigInetTypesIpPrefix ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An IPv4 or IPv6 prefix. " SYNTAX OCTET STRING OpenconfigInetTypesIpVersion ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This value represents the version of the IP protocol. Note that integer representation of the enumerated values are not specified, and are not required to follow the InetVersion textual convention in SMIv2. " SYNTAX INTEGER { unknown (0), ipv4 (4), ipv6 (6) } OpenconfigInetTypesIpv4Address ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An IPv4 address in dotted quad notation using the default zone. " SYNTAX OCTET STRING OpenconfigInetTypesIpv4AddressZoned ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An IPv4 address in dotted quad notation. This type allows specification of a zone index to disambiguate identical address values. For link-local addresses, the index is typically the interface index or interface name. " SYNTAX OCTET STRING OpenconfigInetTypesIpv4Prefix ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An IPv4 prefix represented in dotted quad notation followed by a slash and a CIDR mask (0 <= mask <= 32). " SYNTAX OCTET STRING OpenconfigInetTypesIpv6Address ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An IPv6 address represented as either a full address; shortened or mixed-shortened formats, using the default zone. " SYNTAX OCTET STRING OpenconfigInetTypesIpv6AddressZoned ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An IPv6 address represented as either a full address; shortened or mixed-shortened formats. This type allows specification of a zone index to disambiguate identical address values. For link-local addresses, the index is typically the interface index or interface name. " SYNTAX OCTET STRING OpenconfigInetTypesIpv6FlowLabel ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The IPv6 flow-label is a 20-bit value within the IPv6 header which is optionally used by the source of the IPv6 packet to label sets of packets for which special handling may be required. " SYNTAX Unsigned32 (0..1048575) OpenconfigInetTypesIpv6Prefix ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An IPv6 prefix represented in full, shortened, or mixed shortened format followed by a slash and CIDR mask (0 <= mask <= 128). " SYNTAX OCTET STRING OpenconfigInetTypesPortNumber ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A 16-bit port number used by a transport protocol such as TCP or UDP. " SYNTAX Unsigned32 OpenconfigInetTypesUri ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An ASCII-encoded Uniform Resource Identifier (URI) as defined in RFC 3986. " SYNTAX OCTET STRING OpenconfigInetTypesUrl ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An ASCII-encoded Uniform Resource Locator (URL) as defined in RFC 3986, section 1.1.3 " SYNTAX OCTET STRING OpenconfigInterfacesBaseInterfaceRef ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Reusable type for by-name reference to a base interface. This type may be used in cases where ability to reference a subinterface is not required. " SYNTAX OCTET STRING OpenconfigInterfacesInterfaceId ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "User-defined identifier for an interface, generally used to name a interface reference. The id can be arbitrary but a useful convention is to use a combination of base interface name and subinterface index. " SYNTAX OCTET STRING OpenconfigLldpTypesChassisIdType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type definition with enumerations describing the source of the chassis identifier " SYNTAX INTEGER { chassisComponent (0), interfaceAlias (1), portComponent (2), macAddress (3), networkAddress (4), interfaceName (5), local (6) } OpenconfigLldpTypesPortIdType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type definition with enumerations describing the basis of the port identifier " SYNTAX INTEGER { interfaceAlias (0), portComponent (1), macAddress (2), networkAddress (3), interfaceName (4), agentCircuitId (5), local (6) } OpenconfigPlatformTypesComponentPowerType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A generic type reflecting whether a hardware component is powered on or off " SYNTAX INTEGER { powerEnabled (0), powerDisabled (1) } OpenconfigSystemLoggingSyslogSeverity ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Syslog message severities " SYNTAX INTEGER { emergency (0), alert (1), critical (2), error (3), warning (4), notice (5), informational (6), debug (7) } OpenconfigSystemTimezoneNameType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A time zone name as used by the Time Zone Database, sometimes referred to as the 'Olson Database'. The exact set of valid values is an implementation-specific matter. Client discovery of the exact set of time zone names for a particular server is out of scope. " SYNTAX OCTET STRING OpenconfigTransportTypesAdminStateType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Administrative state modes for logical channels in the transponder model. " SYNTAX INTEGER { enabled (0), disabled (1), maint (2) } OpenconfigTransportTypesFrequencyType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type for optical spectrum frequency values UNITS:MHz" SYNTAX OCTET STRING OpenconfigTransportTypesLoopbackModeType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Loopback modes for transponder logical channels " SYNTAX INTEGER { none (0), facility (1), terminal (2) } OpenconfigTypesIeeefloat32 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An IEEE 32-bit floating point number. The format of this number is of the form: 1-bit sign 8-bit exponent 23-bit fraction The floating point value is calculated using: (-1)**S * 2**(Exponent-127) * (1+Fraction) " SYNTAX OCTET STRING OpenconfigTypesPercentage ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Integer indicating a percentage value " SYNTAX Unsigned32 (0..100) OpenconfigTypesRoutingPassword ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This type is indicative of a password that is used within a routing protocol which can be returned in plain text to the NMS by the local system. Such passwords are typically stored as encrypted strings. Since the encryption used is generally well known, it is possible to extract the original value from the string - and hence this format is not considered secure. Leaves specified with this type should not be modified by the system, and should be returned to the end-user in plain text. This type exists to differentiate passwords, which may be sensitive, from other string leaves. It could, for example, be used by the NMS to censor this data when viewed by particular users. " SYNTAX OCTET STRING OpenconfigTypesStatInterval ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A time interval over which a set of statistics is computed. A common usage is to report the interval over which avg/min/max stats are computed and reported. UNITS:nanoseconds" SYNTAX OCTET STRING OpenconfigTypesStdRegexp ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This type definition is a placeholder for a standard definition of a regular expression that can be utilised in OpenConfig models. Further discussion is required to consider the type of regular expressions that are to be supported. An initial proposal is POSIX compatible. " SYNTAX OCTET STRING OpenconfigTypesTimeticks64 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This type is based on the timeticks type defined in RFC 6991, but with 64-bit width. It represents the time, modulo 2^64, in hundredths of a second between two epochs. " SYNTAX OCTET STRING OpenconfigVlanTypesQinqId ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type definition representing a single double-tagged/QinQ VLAN identifier. The format of a QinQ VLAN-ID is x.y where X is the 'outer' VLAN identifier, and y is the 'inner' VLAN identifier. Both x and y must be valid VLAN IDs (1 <= vlan-id <= 4094) with the exception that y may be equal to a wildcard (*). In cases where y is set to the wildcard, this represents all inner VLAN identifiers where the outer VLAN identifier is equal to x " SYNTAX OCTET STRING OpenconfigVlanTypesQinqIdRange ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A type definition representing a range of double-tagged/QinQ VLAN identifiers. The format of a QinQ VLAN-ID range can be specified in three formats. Where the range is outer VLAN IDs the range is specified as x..y.z. In this case outer VLAN identifiers meeting the criteria x <= outer-vlan-id <= y are accepted iff the inner VLAN-ID is equal to y - or any inner-tag if the wildcard is specified. Alternatively the range can be specified as x.y..z. In this case only VLANs with an outer-vlan-id qual to x are accepted (x may again be the wildcard). Inner VLANs are accepted if they meet the inequality y <= inner-vlan-id <= z. " SYNTAX OCTET STRING OpenconfigVlanTypesVlanId ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type definition representing a single-tagged VLAN " SYNTAX Unsigned32 (1..4094) OpenconfigVlanTypesVlanModeType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "VLAN interface mode (trunk or access) " SYNTAX INTEGER { access (0), trunk (1) } OpenconfigVlanTypesVlanRange ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type definition representing a range of single-tagged VLANs. A range is specified as x..y where x and y are valid VLAN IDs (1 <= vlan-id <= 4094). The range is assumed to be inclusive, such that any VLAN-ID matching x <= VLAN-ID <= y falls within the range. " SYNTAX OCTET STRING OpenconfigVlanTypesVlanRef ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Reference to a VLAN by name or id " SYNTAX OCTET STRING OpenconfigYangTypesCounter32 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A 32-bit counter. A counter value is a monotonically increasing value which is used to express a count of a number of occurrences of a particular event or entity. When the counter reaches its maximum value, in this case 2^32-1, it wraps to 0. Discontinuities in the counter are generally triggered only when the counter is reset to zero. " SYNTAX Unsigned32 OpenconfigYangTypesCounter64 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A 64-bit counter. A counter value is a monotonically increasing value which is used to express a count of a number of occurrences of a particular event or entity. When a counter64 reaches its maximum value, 2^64-1, it loops to zero. Discontinuities in a counter are generally triggered only when the counter is reset to zero, through operator or system intervention. " SYNTAX OCTET STRING OpenconfigYangTypesDate ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A full UTC date, expressed in the format described in RFC3339. That is to say: YYYY-MM-DD where YYYY is the year, MM is the month expressed as a two-digit month (zero padding if required), DD is the day of the month, expressed as a two digit value. " SYNTAX OCTET STRING OpenconfigYangTypesDateAndTime ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A date and time, expressed in the format described in RFC3339. That is to say: YYYY-MM-DDTHH:MM:SSZ+-hh:mm where YYYY is the year, MM is the month expressed as a two-digit month (zero padding if required), DD is the day of the month, expressed as a two digit value. T is the literal character 'T', HH is the hour of the day expressed as a two digit number, using the 24-hour clock, MM is the minute of the hour expressed as a two digit number. Z is the literal character 'Z', followed by a timezone offset expressed in hours (hh) and minutes (mm), both expressed as two digit numbers. The time offset is specified as a positive or negative offset to UTC using the '+' or '-' character preceding the offset. Optionally, fractional seconds can be expressed after the minute of the hour as a decimal number of unspecified precision reflecting fractions of a second. " SYNTAX OCTET STRING OpenconfigYangTypesDottedQuad ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An unsigned 32-bit integer expressed as a dotted quad. The format is four octets written as decimal numbers separated with a period character. " SYNTAX OCTET STRING OpenconfigYangTypesGauge64 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A gauge value may increase or decrease - and reflects a value at a particular point in time. If the value of the variable being modeled using the gauge exceeds its maximum - 2^64-1 in this case - the gauge is set to its maximum value. " SYNTAX OCTET STRING OpenconfigYangTypesHexString ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A string consisting of a hexadecimal characters. " SYNTAX OCTET STRING OpenconfigYangTypesMacAddress ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "An IEEE 802 MAC address " SYNTAX OCTET STRING OpenconfigYangTypesPhysAddress ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A physical layer address, expressed as a series of pairs of hexadecimal digits. " SYNTAX OCTET STRING OpenroadmAugmentActivateNotificationType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type of notification on software or database activation events " SYNTAX INTEGER { activate (1), commit (2), cancel (3) } OpenroadmAugmentInterfaceType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { if100ge (0), ifOms (1), ifOts (2), ifOch (3), if1ge (4), if10ge (5), if40ge (6), ifOchOtu1Odu1 (7), ifOchOtu2Odu2 (8), ifOchOtu2eOdu2e (9), ifOchOtu3Odu3 (10), ifOchOtu4Odu4 (11), ifOtu4Odu4 (12), ifOtu1Odu1 (13), ifOtu2Odu2 (14), ifOtu2eOdu2e (15), ifOtu3Odu3 (16), if1geOdu0 (17), if10geOdu2 (18), if10geOdu2e (19), if40geOdu3 (20), if100geOdu4 (21) } OpenroadmAugmentPmNamesEnum ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { vendorextension (1), biterrorrate (2), opticalpoweroutput (3), opticalreturnloss (4), opticalpowerinput (5), codeviolations (8), erroredseconds (9), severelyerroredseconds (10), unavailableseconds (11), inframes (12), inframeserrored (13), outframes (14), erroredsecondsethernet (15), severelyerroredsecondsethernet (16), unavailablesecondsethernet (17), erroredblockcount (18), delay (19), defectseconds (20), backwardincomingalignmenterror (21), incomingalignmenterror (22), opticalpoweroutputmin (23), opticalpoweroutputmax (24), opticalpoweroutputavg (25), opticalpowerinputmin (26), opticalpowerinputmax (27), opticalpowerinputavg (28), opticalpoweroutputosc (29), opticalpoweroutputoscmin (30), opticalpoweroutputoscmax (31), opticalpoweroutputoscavg (32), opticalpowerinputosc (33), opticalpowerinputoscmin (34), opticalpowerinputoscmax (35), opticalpowerinputoscavg (36), prefeccorrectederrors (37), totalopticalpowerinput (38), totalopticalpowerinputmin (39), totalopticalpowerinputmax (40), totalopticalpowerinputavg (41), feccorrectableblocks (42), fecuncorrectableblocks (43), biperrorcounter (56), protectionswitchingcount (57), protectionswitchingduration (58), erroredblockcounttcm1Up (59), erroredblockcounttcm2Up (60), erroredblockcounttcm3Up (61), erroredblockcounttcm4Up (62), erroredblockcounttcm5Up (63), erroredblockcounttcm6Up (64), delaytcm1Up (65), delaytcm2Up (66), delaytcm3Up (67), delaytcm4Up (68), delaytcm5Up (69), delaytcm6Up (70), erroredblockcounttcm1Down (71), erroredblockcounttcm2Down (72), erroredblockcounttcm3Down (73), erroredblockcounttcm4Down (74), erroredblockcounttcm5Down (75), erroredblockcounttcm6Down (76), delaytcm1Down (77), delaytcm2Down (78), delaytcm3Down (79), delaytcm4Down (80), delaytcm5Down (81), delaytcm6Down (82) } OpenroadmAugmentResourceNotificationType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type of notification about a resource " SYNTAX INTEGER { resourcecreation (1), resourcemodification (2), resourcedeletion (3) } OpenroadmAugmentResourceTypeEnum ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { other (1), device (2), degree (3), sharedRiskGroup (4), connection (5), connectionMap (6), port (7), circuitPack (8), internalLink (9), physicalLink (10), interface (11), shelf (12), service (13), oduSncpPg (14), lineAmplifier (15), xponder (16), versionedService (17), tempService (18) } OpenroadmAugmentStates ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { reservedForFacilityPlanned (1), notReservedPlanned (2), reservedForMaintenancePlanned (3), reservedForFacilityUnvalidated (4), notReservedUnvalidated (5), unknownUnvalidated (6), reservedForMaintenanceUnvalidated (7), reservedForFacilityAvailable (8), notReservedAvailable (9), reservedForMaintenanceAvailable (10), reservedForReversionInuse (11), notReservedInuse (12), reservedForMaintenanceInuse (13) } OpenroadmAugmentUsernameType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The user name string identifying this entry. " SYNTAX OCTET STRING (SIZE (3..32)) OpticalCommonAttControlMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Attenuation control mode. " SYNTAX INTEGER { notApplicable (0), auto (1), manual (2), gainloss (3), off (4), power (5) } OpticalCommonChannelWorkingMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { noMonitor (0), monitor (1), powerControl (2) } OpticalCommonSupportingPort ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "References one individual port, or no port at all " SYNTAX OCTET STRING OrgOpenroadmCommonTypesActivateNotificationType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type of notification on software or database activation events " SYNTAX INTEGER { activate (1), commit (2), cancel (3) } OrgOpenroadmCommonTypesAmplifierGainRange ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Operational mode for the amplifier: this parameter allows modeling different operational modes (gain ranges) ,notably for switched-gain amplifiers. It indicates which performance model shall be used by the path feasibility engine. For standard amplifier, or when performance evaluation is based on incremental noise, use gain-range-1. When performance evaluation is based on advanced parameters, specify used gain-range (1 to 4). Up to release 2.1, only gain-range-1 is to be used (default value) " SYNTAX INTEGER { gainRange1 (1), gainRange2 (2), gainRange3 (3), gainRange4 (4) } OrgOpenroadmCommonTypesAmplifierTypes ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "identifier for amplifier type 1. standard for amplifier as defined initially in the ROADM MSA specifications To be completed if/when additional amplifier types are required " SYNTAX INTEGER { standard (1) } OrgOpenroadmCommonTypesDirection ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { tx (1), rx (2), bidirectional (3), notapplicable (4) } OrgOpenroadmCommonTypesEquipmentTypeEnum ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { other (1), powersupply (2), shelfprocessor (3), crossconnect (4), fan (5), accesspanel (6), circuitpack (7) } OrgOpenroadmCommonTypesExtendedRpcStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "status of RPC " SYNTAX INTEGER { successful (1), failed (2), inProgress (3) } OrgOpenroadmCommonTypesFiberPmd ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Polarization Mode Dispersion expressed in ps/km(1/2). UNITS:ps/(km[1/2])" SYNTAX OCTET STRING OrgOpenroadmCommonTypesFrequencyGHz ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Frequency value in GHz. UNITS:GHz" SYNTAX OCTET STRING OrgOpenroadmCommonTypesFrequencyTHz ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Frequency value in THz. UNITS:THz" SYNTAX OCTET STRING OrgOpenroadmCommonTypesLifecycleState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Lifecycle state. " SYNTAX INTEGER { deployed (1), planned (2), maintenance (3), deploying (4), undeploying (5), undeployed (6), proposed (7), draft (8), deployFailed (9), undeployFailed (10) } OrgOpenroadmCommonTypesLineAmplifierControlMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Identifies the line amplifier control mode, either off or gain. " SYNTAX INTEGER { gainloss (2), off (3) } OrgOpenroadmCommonTypesLocation ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { notapplicable (1), nearend (2), farend (3) } OrgOpenroadmCommonTypesModulationFormat ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Modulation format " SYNTAX INTEGER { bpsk (0), dcDpBpsk (1), qpsk (2), dpQpsk (3), qam16 (4), dpQam16 (5), dcDpQam16 (6), qam8 (7), dpQam8 (8), dcDpQam8 (9) } OrgOpenroadmCommonTypesNodeIdType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Globally unique identifer for a device. " SYNTAX OCTET STRING (SIZE (7..63)) OrgOpenroadmCommonTypesNodeTypes ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Identifier for node type 1. rdm for ROADM 2. xpdr for Transponder, Regen 3. ila for in-line amplifier 4. extplug for external plugable " SYNTAX INTEGER { rdm (1), xpdr (2), ila (3), extplug (4) } OrgOpenroadmCommonTypesOpenroadmVersionType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "OpenROADM version enum type " SYNTAX INTEGER { t10 (1), t20 (2), t21 (3), t22 (4), t221 (8) } OrgOpenroadmCommonTypesOpticTypes ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { gray (1), dwdm (2) } OrgOpenroadmCommonTypesOpticalControlMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Optical Control Mode: identifies specific algorithm related to power management and general optical control. " SYNTAX INTEGER { power (1), gainloss (2), off (3) } OrgOpenroadmCommonTypesPortQual ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { roadmInternal (1), roadmExternal (2), xpdrNetwork (3), xpdrClient (4), otdr (5), switchNetwork (6), switchClient (7), ilaExternal (8), ilaInternal (9) } OrgOpenroadmCommonTypesPowerDBm ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Power value in dBm. UNITS:dBm" SYNTAX OCTET STRING OrgOpenroadmCommonTypesRatioDB ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Power ratio in dB. UNITS:dB" SYNTAX OCTET STRING OrgOpenroadmCommonTypesRpcStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "status of RPC " SYNTAX INTEGER { successful (1), failed (2) } OrgOpenroadmCommonTypesSeverity ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Severity, based on X.733 perceived severity " SYNTAX INTEGER { critical (1), major (2), minor (3), warning (4), clear (5), indeterminate (6) } OrgOpenroadmCommonTypesState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "State that indicates whether the resource is able to provide fullfill its role - carry traffic, etc. " SYNTAX INTEGER { inservice (1), outofservice (2), degraded (3) } OrgOpenroadmCommonTypesWavelengthDuplicationType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "One per srg is applied to C/D add/drop group one per degree is applied to C/D/C add drop group " SYNTAX INTEGER { onePerSrg (1), onePerDegree (2) } OrgOpenroadmCommonTypesXpdrNodeTypes ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Identifier for Xponder node type 1. Transponder 2. Muxponder 3. OTN switchponder 4. Regenerator 5. Regenerator based on unidirectional model " SYNTAX INTEGER { tpdr (1), mpdr (2), switch (3), regen (4), regenUni (5) } OrgOpenroadmEquipmentStatesTypesAdminStates ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { inservice (1), outofservice (2), maintenance (3) } OrgOpenroadmEquipmentStatesTypesStates ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { reservedForFacilityPlanned (1), notReservedPlanned (2), reservedForMaintenancePlanned (3), reservedForFacilityUnvalidated (4), notReservedUnvalidated (5), unknownUnvalidated (6), reservedForMaintenanceUnvalidated (7), reservedForFacilityAvailable (8), notReservedAvailable (9), reservedForMaintenanceAvailable (10), reservedForReversionInuse (11), notReservedInuse (12), reservedForMaintenanceInuse (13) } OrgOpenroadmLayerRateLayerRateEnum ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { vendorextension (1), layer2 (2), layer3 (3), layer4 (4), layer5 (5), layer6 (6) } OrgOpenroadmMaintenanceMaintenanceOperation ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Maintenance Operation. " SYNTAX INTEGER { terminalloopback (1), facilityloopback (2), testsignal (3) } OrgOpenroadmOtnCommonTypesPayloadTypeDef ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Common type definition for odu payload-type " SYNTAX OCTET STRING (SIZE (2)) OrgOpenroadmPmTypesPmDataType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING OrgOpenroadmPmTypesPmGranularity ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Granularity of PM bin " SYNTAX INTEGER { notapplicable (1), t15min (2), t24hour (3) } OrgOpenroadmPmTypesPmNamesEnum ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { vendorextension (1), biterrorrate (2), opticalpoweroutput (3), opticalreturnloss (4), opticalpowerinput (5), codeviolations (8), erroredseconds (9), severelyerroredseconds (10), unavailableseconds (11), inframes (12), inframeserrored (13), outframes (14), erroredsecondsethernet (15), severelyerroredsecondsethernet (16), unavailablesecondsethernet (17), erroredblockcount (18), delay (19), defectseconds (20), backwardincomingalignmenterror (21), incomingalignmenterror (22), opticalpoweroutputmin (23), opticalpoweroutputmax (24), opticalpoweroutputavg (25), opticalpowerinputmin (26), opticalpowerinputmax (27), opticalpowerinputavg (28), opticalpoweroutputosc (29), opticalpoweroutputoscmin (30), opticalpoweroutputoscmax (31), opticalpoweroutputoscavg (32), opticalpowerinputosc (33), opticalpowerinputoscmin (34), opticalpowerinputoscmax (35), opticalpowerinputoscavg (36), prefeccorrectederrors (37), totalopticalpowerinput (38), totalopticalpowerinputmin (39), totalopticalpowerinputmax (40), totalopticalpowerinputavg (41), feccorrectableblocks (42), fecuncorrectableblocks (43), biperrorcounter (56), protectionswitchingcount (57), protectionswitchingduration (58), erroredblockcounttcm1Up (59), erroredblockcounttcm2Up (60), erroredblockcounttcm3Up (61), erroredblockcounttcm4Up (62), erroredblockcounttcm5Up (63), erroredblockcounttcm6Up (64), delaytcm1Up (65), delaytcm2Up (66), delaytcm3Up (67), delaytcm4Up (68), delaytcm5Up (69), delaytcm6Up (70), erroredblockcounttcm1Down (71), erroredblockcounttcm2Down (72), erroredblockcounttcm3Down (73), erroredblockcounttcm4Down (74), erroredblockcounttcm5Down (75), erroredblockcounttcm6Down (76), delaytcm1Down (77), delaytcm2Down (78), delaytcm3Down (79), delaytcm4Down (80), delaytcm5Down (81), delaytcm6Down (82) } OrgOpenroadmPmTypesValidity ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Validity of data " SYNTAX INTEGER { complete (1), partial (2), suspect (3) } OrgOpenroadmPortCapabilityTcmDirectionCapabilityType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "TCM direction capability for the port " SYNTAX INTEGER { upTcm (0), downTcm (1), upDownTcm (2) } OrgOpenroadmPortTypesPortWavelengthTypes ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Port types. " SYNTAX INTEGER { wavelength (1), multiWavelength (2) } OrgOpenroadmProbableCauseProbableCauseEnum ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { vendorextension (1), openconnectionindication (2), alarmindicationsignal (3), lossofsignal (4), opticallinefail (5), opticalpowerdegraded (6), automaticlasershutdown (7), serversignalfail (8), lockeddefect (10), trailtraceidentifiermismatch (11), degradeddefect (12), backwardsdefectindication (13), otsspanlosspoweroutofspecificationhigh (14), automaticshutoffdisabled (15), portlossoflight (17), reflectiontoohigh (18), payloadmissingindication (22), forwarddefectindication (23), oscpoweroutofspecificationhigh (24), oscpoweroutofspecificationlow (25), poweroutofspecificationhigh (26), lossofsynchronization (27), linkdown (28), equipmentfault (29), equipmentremoved (30), equipmentmismatch (31), equipmentwarmup (32), equipmentledon (33), equipmentinterconnectfailure (34), equipmentmiscabledconnection (35), softwareversionmismatch (36), softwarestageinprogress (37), databasecorruption (38), databaseversionmismatch (44), firmwareversionmismatch (46), incompatiblefirmware (49), firmwaredownloadoractivationfailure (50), firmwareinitinprogress (51), softwarereset (52), fancoolingfail (53), administrativedown (54), lamptest (55), powerproblema (56), powerproblemb (57), shelfprovisioningmode (58), sysnamechanged (59), sysntpnotsynchronized (60), lossofframe (63), lossofmultiframe (64), backwardincomingalignmenterror (65), incomingalignmenterror (66), payloadmismatch (67), clientsignalfaildefect (68), highber (123), localfault (124), remotefault (125), lossofalignment (126), lossoffecalignment (127), facilityloopbackactive (128), facilityloopback2active (129), terminalloopbackactive (130), facilitytestsignalactive (131), terminaltestsignalactive (132), certificatenotinstalled (134), lockoutofprotection (135), forcedswitchawayfromworking (136), forcedswitchawayfromprotect (137), automaticswitchawayfromworkingduetosf (138), automaticswitchawayfromprotectduetosf (139), automaticswitchduetowtr (140), manualswitchawayfromwork (141), manualswitchawayfromprotect (142), automaticpowerreduction (143), lossofsignalosc (144), softwarevalidateinprogress (145), databaserollbacktimerinprogress (146), otdrscaninprogress (147), lldpfail (148), omspoweroutofspecificationhigh (149), omspoweroutofspecificationlow (150), automaticswitchawayfromworkingduetosd (151), automaticswitchawayfromprotectduetosd (152), backwardincomingalignmenterrortcm1Up (153), backwardincomingalignmenterrortcm2Up (154), backwardincomingalignmenterrortcm3Up (155), backwardincomingalignmenterrortcm4Up (156), backwardincomingalignmenterrortcm5Up (157), backwardincomingalignmenterrortcm6Up (158), incomingalignmenterrortcm1Up (159), incomingalignmenterrortcm2Up (160), incomingalignmenterrortcm3Up (161), incomingalignmenterrortcm4Up (162), incomingalignmenterrortcm5Up (163), incomingalignmenterrortcm6Up (164), backwardsdefectindicationtcm1Up (165), backwardsdefectindicationtcm2Up (166), backwardsdefectindicationtcm3Up (167), backwardsdefectindicationtcm4Up (168), backwardsdefectindicationtcm5Up (169), backwardsdefectindicationtcm6Up (170), degradeddefecttcm1Up (171), degradeddefecttcm2Up (172), degradeddefecttcm3Up (173), degradeddefecttcm4Up (174), degradeddefecttcm5Up (175), degradeddefecttcm6Up (176), trailtraceidentifiermismatchtcm1Up (177), trailtraceidentifiermismatchtcm2Up (178), trailtraceidentifiermismatchtcm3Up (179), trailtraceidentifiermismatchtcm4Up (180), trailtraceidentifiermismatchtcm5Up (181), trailtraceidentifiermismatchtcm6Up (182), alarmindicationsignaltcm1Up (183), alarmindicationsignaltcm2Up (184), alarmindicationsignaltcm3Up (185), alarmindicationsignaltcm4Up (186), alarmindicationsignaltcm5Up (187), alarmindicationsignaltcm6Up (188), openconnectionindicationtcm1Up (189), openconnectionindicationtcm2Up (190), openconnectionindicationtcm3Up (191), openconnectionindicationtcm4Up (192), openconnectionindicationtcm5Up (193), openconnectionindicationtcm6Up (194), lockeddefecttcm1Up (195), lockeddefecttcm2Up (196), lockeddefecttcm3Up (197), lockeddefecttcm4Up (198), lockeddefecttcm5Up (199), lockeddefecttcm6Up (200), lossoftandemconnectiontcm1Up (201), lossoftandemconnectiontcm2Up (202), lossoftandemconnectiontcm3Up (203), lossoftandemconnectiontcm4Up (204), lossoftandemconnectiontcm5Up (205), lossoftandemconnectiontcm6Up (206), backwardincomingalignmenterrortcm1Down (207), backwardincomingalignmenterrortcm2Down (208), backwardincomingalignmenterrortcm3Down (209), backwardincomingalignmenterrortcm4Down (210), backwardincomingalignmenterrortcm5Down (211), backwardincomingalignmenterrortcm6Down (212), incomingalignmenterrortcm1Down (213), incomingalignmenterrortcm2Down (214), incomingalignmenterrortcm3Down (215), incomingalignmenterrortcm4Down (216), incomingalignmenterrortcm5Down (217), incomingalignmenterrortcm6Down (218), backwardsdefectindicationtcm1Down (219), backwardsdefectindicationtcm2Down (220), backwardsdefectindicationtcm3Down (221), backwardsdefectindicationtcm4Down (222), backwardsdefectindicationtcm5Down (223), backwardsdefectindicationtcm6Down (224), degradeddefecttcm1Down (225), degradeddefecttcm2Down (226), degradeddefecttcm3Down (227), degradeddefecttcm4Down (228), degradeddefecttcm5Down (229), degradeddefecttcm6Down (230), trailtraceidentifiermismatchtcm1Down (231), trailtraceidentifiermismatchtcm2Down (232), trailtraceidentifiermismatchtcm3Down (233), trailtraceidentifiermismatchtcm4Down (234), trailtraceidentifiermismatchtcm5Down (235), trailtraceidentifiermismatchtcm6Down (236), alarmindicationsignaltcm1Down (237), alarmindicationsignaltcm2Down (238), alarmindicationsignaltcm3Down (239), alarmindicationsignaltcm4Down (240), alarmindicationsignaltcm5Down (241), alarmindicationsignaltcm6Down (242), openconnectionindicationtcm1Down (243), openconnectionindicationtcm2Down (244), openconnectionindicationtcm3Down (245), openconnectionindicationtcm4Down (246), openconnectionindicationtcm5Down (247), openconnectionindicationtcm6Down (248), lockeddefecttcm1Down (249), lockeddefecttcm2Down (250), lockeddefecttcm3Down (251), lockeddefecttcm4Down (252), lockeddefecttcm5Down (253), lockeddefecttcm6Down (254), lossoftandemconnectiontcm1Down (255), lossoftandemconnectiontcm2Down (256), lossoftandemconnectiontcm3Down (257), lossoftandemconnectiontcm4Down (258), lossoftandemconnectiontcm5Down (259), lossoftandemconnectiontcm6Down (260), multiplexstructureidentifiermismatch (261), lossofomfindication (262), lossofframeandlossofmultiframe (263), lossofdatabaseredundancy (264), databaselocked (265), createtechinfoinprogress (266), circuitpackactivatefailed (267), softwaresubsystemfailed (268), diskfull (269) } OrgOpenroadmResourceTypesResourceNotificationType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Type of notification about a resource " SYNTAX INTEGER { resourcecreation (1), resourcemodification (2), resourcedeletion (3) } OrgOpenroadmResourceTypesResourceTypeEnum ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { other (1), device (2), degree (3), sharedRiskGroup (4), connection (5), connectionMap (6), port (7), circuitPack (8), internalLink (9), physicalLink (10), interface (11), shelf (12), service (13), oduSncpPg (14), lineAmplifier (15), xponder (16), versionedService (17), tempService (18) } OrgOpenroadmRstpBridgeIdType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Unique Bridge Identifier " SYNTAX OCTET STRING OrgOpenroadmSwitchingPoolTypesSwitchingPoolTypes ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { nonBlocking (1), blocking (2) } OrgOpenroadmSyslogSeverity ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The definitions for Syslog message severity as per RFC 5424. Extended the RFC definition with enums for all and none " SYNTAX INTEGER { emergency (0), alert (1), critical (2), error (3), warning (4), notice (5), info (6), debug (7), all (8), none (9) } OrgOpenroadmUserMgmtPasswordType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The password for this entry. This shouldn't be in clear text The Password must contain at least 2 characters from each of the following groups: a) Lower case alphabetic (a-z) b) Upper case alphabetic (A-Z) c) Numeric 0-9 d) Special characters Allowed !$%^()[]_-~{}.+ Password must not contain Username. " SYNTAX OCTET STRING (SIZE (8..128)) OrgOpenroadmUserMgmtUsernameType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The user name string identifying this entry. " SYNTAX OCTET STRING (SIZE (3..32)) OtdrOtdrIor ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING OtdrOtdrPulseWidth ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING OtdrOtdrRange ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING QsfpSignalIntegrityControlVal ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX OCTET STRING QsfpSignalIntegritySignalVal ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "NULL " SYNTAX INTEGER { nA (0), true (1), false (2) } RstpBridgeIdType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Unique Bridge Identifier " SYNTAX OCTET STRING (SIZE (1..255)) SecurityGrpcCertificateRef ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "certificate to be referred to. " SYNTAX OCTET STRING SecurityLocalCertificateRef ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "certificate to be referred to. " SYNTAX OCTET STRING SecurityTrustedCertificateGroupRef ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "trusted-certificate-group to be referred to. " SYNTAX OCTET STRING coriant OBJECT IDENTIFIER ::= { enterprises 42229 } products OBJECT IDENTIFIER ::= { coriant 1 } fault OBJECT IDENTIFIER ::= { groove 1 } notificationInfo OBJECT IDENTIFIER ::= { fault 1 } notificationObject OBJECT IDENTIFIER ::= { notificationInfo 1 } notificationFmEntity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The management object instance which the alarm or condition is reported against. " ::= { notificationObject 1 } notificationConditionType OBJECT-TYPE SYNTAX CoriantFmtypesConditionType MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the current standing conditions which cause alarms and/or events. " ::= { notificationObject 2 } notificationLocation OBJECT-TYPE SYNTAX CoriantTypesManagementLocation MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates if the alarm or event location is near end or far end. " ::= { notificationObject 3 } notificationDirection OBJECT-TYPE SYNTAX CoriantTypesManagementDirection MAX-ACCESS read-only STATUS current DESCRIPTION " Specifies the direction of an event/occurrence in the system, Ingress, Egress, NA. " ::= { notificationObject 4 } notificationTimePeriod OBJECT-TYPE SYNTAX CoriantTypesManagementTimePeriod MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the time-period increments during which PM data is collected. " ::= { notificationObject 5 } notificationServiceAffect OBJECT-TYPE SYNTAX CoriantFmtypesServiceAffectFm MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates if an alarm is service affecting or non-service affecting. NSA indicates non-service affecting. SA indicates service affecting. " ::= { notificationObject 6 } notificationSeverityLevel OBJECT-TYPE SYNTAX CoriantFmtypesSeverityLevel MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the notification code (severity level) associated with the alarm type of service affecting. " ::= { notificationObject 7 } notificationOccurrenceDateTime OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the occurrence date and time of the alarm by the month of the year, the day of the month, hour of the day, the minute of the hour, and the second of the minute. " ::= { notificationObject 8 } notificationConditionDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION " Describes the condition that caused the alarm. " ::= { notificationObject 9 } notificationAlarmConditionType OBJECT-TYPE SYNTAX INTEGER { standing (1), transient (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm condition types, for example, standing or transient. " ::= { notificationObject 10 } notificationLastSeverityLevel OBJECT-TYPE SYNTAX CoriantFmtypesSeverityLevel MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the last severity level associated with the alarm type, which provides the info of alarm severity declared and cleared. " ::= { notificationObject 11 } notificationExtensionDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION " The description in alarm notification to provide additional information. " ::= { notificationObject 12 } notificationFmEntityType OBJECT-TYPE SYNTAX CoriantFmtypesEntityTypeFm MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the entity type the condition associated, which provides additional information for the object instance having the condition. entity type is not exactly same as MO. Entity type have smaller granularity referring to different service functions, e.g. 100GBase-R, 40GBase-R, 100GBase-R, ODU4, ODU2, ODU3, OTU4, OTUC2... Separate functions will have different entity types so that profile can be set differently for different service function which is more corresponding to user application. " ::= { notificationObject 13 } notificationAlarmId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "A system assigned unique identified to the alarm. " ::= { notificationObject 14 } notificationTrap OBJECT IDENTIFIER ::= { fault 2 } alarmNotification NOTIFICATION-TYPE OBJECTS { notificationFmEntity,notificationConditionType,notificationLocation,notificationDirection,notificationTimePeriod,notificationServiceAffect,notificationSeverityLevel,notificationOccurrenceDateTime,notificationConditionDescription,notificationFmEntityType,notificationAlarmConditionType,notificationLastSeverityLevel,notificationExtensionDescription,notificationAlarmId } STATUS current DESCRIPTION "" ::= { notificationTrap 1 } notAlarmedEventNotification NOTIFICATION-TYPE OBJECTS { notificationFmEntity,notificationConditionType,notificationLocation,notificationDirection,notificationTimePeriod,notificationServiceAffect,notificationSeverityLevel,notificationOccurrenceDateTime,notificationConditionDescription,notificationFmEntityType,notificationAlarmConditionType,notificationLastSeverityLevel,notificationExtensionDescription,notificationAlarmId } STATUS current DESCRIPTION "" ::= { notificationTrap 2 } alarmProfile OBJECT IDENTIFIER ::= { fault 4 } alarmProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Alarm profile defines the severity profile of alarm and event." ::= { alarmProfile 1 } alarmProfileEntry OBJECT-TYPE SYNTAX AlarmProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of alarmProfileTable" INDEX { alarmProfileId } ::= { alarmProfileTable 1 } AlarmProfileEntry ::= SEQUENCE { alarmProfileId Unsigned32 } alarmProfileId OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION " alarm profile identifier which uniquely specify alarm profile. alarm profile 1 is supported firstly and applicable to all entities implicitly. " ::= { alarmProfileEntry 1 } alarmProfileENTR OBJECT IDENTIFIER ::= { fault 5 } alarmProfileENTRTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmProfileENTREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The list includes alarm/event entries of an alarm-profile." ::= { alarmProfileENTR 1 } alarmProfileENTREntry OBJECT-TYPE SYNTAX AlarmProfileENTREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of alarmProfileENTRTable" INDEX { alarmProfileId,alarmProfileENTRConditionType,alarmProfileENTRFmEntityType,alarmProfileENTRTimePeriod } ::= { alarmProfileENTRTable 1 } AlarmProfileENTREntry ::= SEQUENCE { alarmProfileENTRConditionType CoriantFmtypesConditionType, alarmProfileENTRFmEntityType CoriantFmtypesEntityTypeFm, alarmProfileENTRTimePeriod CoriantTypesManagementTimePeriod, alarmProfileENTRSeverityLevelSa CoriantFmtypesSeverityLevel, alarmProfileENTRSeverityLevelNsa CoriantFmtypesSeverityLevel } alarmProfileENTRConditionType OBJECT-TYPE SYNTAX CoriantFmtypesConditionType MAX-ACCESS read-only STATUS current DESCRIPTION " Identifies the current standing conditions which cause conditions and/or events. " ::= { alarmProfileENTREntry 1 } alarmProfileENTRFmEntityType OBJECT-TYPE SYNTAX CoriantFmtypesEntityTypeFm MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the entity type the condition associated, which provides additional information for the object instance having the condition. entity type is not exactly same as MO. Entity type have smaller granularity referring to different service functions, e.g. 100GBase-R, 40GBase-R, 100GBase-R, ODU4, ODU2, ODU3, OTU4, OTUC2... Separate functions will have different entity types so that profile can be set differently for different service function which is more corresponding to user application. " ::= { alarmProfileENTREntry 2 } alarmProfileENTRTimePeriod OBJECT-TYPE SYNTAX CoriantTypesManagementTimePeriod MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the time-period increments during which PM data is collected. " ::= { alarmProfileENTREntry 3 } alarmProfileENTRSeverityLevelSa OBJECT-TYPE SYNTAX CoriantFmtypesSeverityLevel MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the notification code (severity level) associated with the condition type of service affecting. " ::= { alarmProfileENTREntry 4 } alarmProfileENTRSeverityLevelNsa OBJECT-TYPE SYNTAX CoriantFmtypesSeverityLevel MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the notification code (severity level) associated with the condition type of non-service affecting. " ::= { alarmProfileENTREntry 5 } standingCondition OBJECT IDENTIFIER ::= { fault 6 } standingConditionTable OBJECT-TYPE SYNTAX SEQUENCE OF StandingConditionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The list includes active standing alarms." ::= { standingCondition 1 } standingConditionEntry OBJECT-TYPE SYNTAX StandingConditionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of standingConditionTable" INDEX { standingConditionFmEntity,standingConditionConditionType,standingConditionLocation,standingConditionDirection,standingConditionTimePeriod } ::= { standingConditionTable 1 } StandingConditionEntry ::= SEQUENCE { standingConditionFmEntity RowPointer, standingConditionConditionType CoriantFmtypesConditionType, standingConditionLocation CoriantTypesManagementLocation, standingConditionDirection CoriantTypesManagementDirection, standingConditionTimePeriod CoriantTypesManagementTimePeriod, standingConditionServiceAffect CoriantFmtypesServiceAffectFm, standingConditionSeverityLevel CoriantFmtypesSeverityLevel, standingConditionOccurrenceDateTime IetfYangTypesDateAndTime, standingConditionConditionDescription OCTET STRING, standingConditionFmEntityType CoriantFmtypesEntityTypeFm, standingConditionAlarmId OCTET STRING } standingConditionFmEntity OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "The management object instance which the alarm or condition is reported against. " ::= { standingConditionEntry 1 } standingConditionConditionType OBJECT-TYPE SYNTAX CoriantFmtypesConditionType MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the current standing conditions which cause alarms and/or events. " ::= { standingConditionEntry 2 } standingConditionLocation OBJECT-TYPE SYNTAX CoriantTypesManagementLocation MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates if the alarm or event location is near end or far end. " ::= { standingConditionEntry 3 } standingConditionDirection OBJECT-TYPE SYNTAX CoriantTypesManagementDirection MAX-ACCESS read-only STATUS current DESCRIPTION " Specifies the direction of an event/occurrence in the system, Ingress, Egress, NA. " ::= { standingConditionEntry 4 } standingConditionTimePeriod OBJECT-TYPE SYNTAX CoriantTypesManagementTimePeriod MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the time-period increments during which PM data is collected. " ::= { standingConditionEntry 5 } standingConditionServiceAffect OBJECT-TYPE SYNTAX CoriantFmtypesServiceAffectFm MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates if an alarm is service affecting or non-service affecting. NSA indicates non-service affecting. SA indicates service affecting. " ::= { standingConditionEntry 6 } standingConditionSeverityLevel OBJECT-TYPE SYNTAX CoriantFmtypesSeverityLevel MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the notification code (severity level) associated with the alarm type of service affecting. " ::= { standingConditionEntry 7 } standingConditionOccurrenceDateTime OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the occurrence date and time of the alarm by the month of the year, the day of the month, hour of the day, the minute of the hour, and the second of the minute. " ::= { standingConditionEntry 8 } standingConditionConditionDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION " Describes the condition that caused the alarm. " ::= { standingConditionEntry 9 } standingConditionFmEntityType OBJECT-TYPE SYNTAX CoriantFmtypesEntityTypeFm MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the entity type the condition associated, which provides additional information for the object instance having the condition. entity type is not exactly same as MO. Entity type have smaller granularity referring to different service functions, e.g. 100GBase-R, 40GBase-R, 100GBase-R, ODU4, ODU2, ODU3, OTU4, OTUC2... Separate functions will have different entity types so that profile can be set differently for different service function which is more corresponding to user application. " ::= { standingConditionEntry 10 } standingConditionAlarmId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "A system assigned unique identified to the alarm. " ::= { standingConditionEntry 11 } ne OBJECT IDENTIFIER ::= { groove 2 } neInfo OBJECT IDENTIFIER ::= { ne 1 } neId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION " Network Element's system identification code. Note that this is unique identifier for each NE. default value :" ::= { neInfo 1 } neName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION " Name assigned to this particular NE. A readable name for the NE. It can be used for NE. But not expected to be used by NM for unique NE identification The different function from ne-id is that user can keep ne-id unchanged, which uniquely identifies the NE, and update ne-name if necessary. default value :" ::= { neInfo 2 } neType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the NE default value :GROOVE_G30" ::= { neInfo 3 } neLocation OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the location of this particular NE " ::= { neInfo 4 } neSite OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name or CLLI of the site where this NE is located " ::= { neInfo 5 } neAltitude OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The altitude of the Network Element in meters UNITS:meters " ::= { neInfo 6 } neVendor OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Vendor name of this NE default value :Infinera" ::= { neInfo 7 } neTemperature OBJECT-TYPE SYNTAX CoriantTypesTemperature MAX-ACCESS read-only STATUS current DESCRIPTION "Ambient temperature sensed by the primary shelf for NE level " ::= { neInfo 8 } system OBJECT IDENTIFIER ::= { ne 2 } systemUnknownPluggableReport OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION " The attribute will enable/disable the alarm reporting for unknown pluggables present on the NE. default value :enabled" ::= { system 1 } systemFactoryResetButton OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION " The attribute will enable/disable factory reset button function on the NE. default value :enabled" ::= { system 4 } systemAutoServiceCreation OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Controls the system behavior regarding auto-creation of services for L1 modules based on port-mode. Only applicable to muxponders (not for transponders). default value :enabled" ::= { system 5 } systemMultiShelf OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION " The attribute will enable/disable multi-shelf function on the NE. default value :disabled" ::= { system 6 } console OBJECT IDENTIFIER ::= { ne 3 } consoleBaudRate OBJECT-TYPE SYNTAX INTEGER { t9600 (6), t19200 (7), t38400 (8), t57600 (11), t115200 (12) } MAX-ACCESS read-only STATUS current DESCRIPTION "The baud rate of console port default value :9600" ::= { console 1 } consoleEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "User configurable switch to enable or disable the console port default value :true" ::= { console 2 } ssh OBJECT IDENTIFIER ::= { ne 6 } sshEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "User configurable switch to enable or disable shell access via SSH default value :false" ::= { ssh 1 } sshPort OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The port that is listening for Linux shell ssh access default value :8022" ::= { ssh 2 } sshTimeout OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Set the idle timeout in seconds on terminal connections to the system for console port and ssh debug port.Setting the value to 0 disables this attribute (meaning the session will not time out). UNITS:seconds default value :0" ::= { ssh 3 } modelSelection OBJECT IDENTIFIER ::= { ne 7 } modelSelectionOpenconfig OBJECT-TYPE SYNTAX INTEGER { enhanced (1), false (2), standard (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The openconfig working mode default value :false" ::= { modelSelection 1 } shelfPowerConsumption OBJECT IDENTIFIER ::= { ne 9 } shelfPowerConsumptionTable OBJECT-TYPE SYNTAX SEQUENCE OF ShelfPowerConsumptionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { shelfPowerConsumption 1 } shelfPowerConsumptionEntry OBJECT-TYPE SYNTAX ShelfPowerConsumptionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of shelfPowerConsumptionTable" INDEX { shelfPowerConsumptionShelfEntity,shelfPowerConsumptionMagic } ::= { shelfPowerConsumptionTable 1 } ShelfPowerConsumptionEntry ::= SEQUENCE { shelfPowerConsumptionShelfEntity RowPointer, shelfPowerConsumptionMagic Unsigned32, shelfPowerConsumptionPowerConsumptionCurrent CoriantTypesPower, shelfPowerConsumptionPowerConsumptionEstimatedMax CoriantTypesPower } shelfPowerConsumptionShelfEntity OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { shelfPowerConsumptionEntry 1 } shelfPowerConsumptionMagic OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { shelfPowerConsumptionEntry 2 } shelfPowerConsumptionPowerConsumptionCurrent OBJECT-TYPE SYNTAX CoriantTypesPower MAX-ACCESS read-only STATUS current DESCRIPTION "Current power consumption of the system. " ::= { shelfPowerConsumptionEntry 3 } shelfPowerConsumptionPowerConsumptionEstimatedMax OBJECT-TYPE SYNTAX CoriantTypesPower MAX-ACCESS read-only STATUS current DESCRIPTION "Derived maximal power consumption around room temperature. " ::= { shelfPowerConsumptionEntry 4 } l2Dcn OBJECT IDENTIFIER ::= { ne 10 } l2DcnIpAddress OBJECT-TYPE SYNTAX IetfInetTypesIpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP Address of device " ::= { l2Dcn 1 } l2DcnPrefixLength OBJECT-TYPE SYNTAX Unsigned32 (0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The length of the subnet prefix " ::= { l2Dcn 2 } l2DcnDefaultGateway OBJECT-TYPE SYNTAX IetfInetTypesIpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Default Gateway " ::= { l2Dcn 3 } l2DcnSource OBJECT-TYPE SYNTAX INTEGER { static (1), dhcp (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { l2Dcn 4 } l2DcnCurrentIpAddress OBJECT-TYPE SYNTAX IetfInetTypesIpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Current IP Address of device " ::= { l2Dcn 5 } l2DcnCurrentPrefixLength OBJECT-TYPE SYNTAX Unsigned32 (0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The current length of the subnet prefix " ::= { l2Dcn 6 } l2DcnCurrentDefaultGateway OBJECT-TYPE SYNTAX IetfInetTypesIpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Current Default Gateway " ::= { l2Dcn 7 } l2DcnMacAddress OBJECT-TYPE SYNTAX IetfYangTypesMacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "MAC Address of device " ::= { l2Dcn 8 } multishelfFileManagement OBJECT IDENTIFIER ::= { ne 11 } multishelfFileManagementTable OBJECT-TYPE SYNTAX SEQUENCE OF MultishelfFileManagementEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "multishelf-file-management YANG models" ::= { multishelfFileManagement 1 } multishelfFileManagementEntry OBJECT-TYPE SYNTAX MultishelfFileManagementEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of multishelfFileManagementTable" INDEX { multishelfFileManagementShelfId } ::= { multishelfFileManagementTable 1 } MultishelfFileManagementEntry ::= SEQUENCE { multishelfFileManagementShelfId CoriantTypesShelfId } multishelfFileManagementShelfId OBJECT-TYPE SYNTAX CoriantTypesShelfId MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { multishelfFileManagementEntry 1 } deleteFile OBJECT IDENTIFIER ::= { ne 12 } deleteFileTable OBJECT-TYPE SYNTAX SEQUENCE OF DeleteFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { deleteFile 1 } deleteFileEntry OBJECT-TYPE SYNTAX DeleteFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of deleteFileTable" INDEX { multishelfFileManagementShelfId } ::= { deleteFileTable 1 } DeleteFileEntry ::= SEQUENCE { deleteFileFileName OCTET STRING, deleteFileResult INTEGER, deleteFileResultMsg OCTET STRING } deleteFileFileName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { deleteFileEntry 1 } deleteFileResult OBJECT-TYPE SYNTAX INTEGER { successful (0), failed (1), unknown (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { deleteFileEntry 2 } deleteFileResultMsg OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { deleteFileEntry 3 } showFile OBJECT IDENTIFIER ::= { ne 13 } showFileTable OBJECT-TYPE SYNTAX SEQUENCE OF ShowFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { showFile 1 } showFileEntry OBJECT-TYPE SYNTAX ShowFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of showFileTable" INDEX { multishelfFileManagementShelfId } ::= { showFileTable 1 } ShowFileEntry ::= SEQUENCE { showFileFileName OCTET STRING, showFileResult INTEGER, showFileResultMsg OCTET STRING } showFileFileName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { showFileEntry 1 } showFileResult OBJECT-TYPE SYNTAX INTEGER { successful (0), failed (1), unknown (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { showFileEntry 2 } showFileResultMsg OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..511)) MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { showFileEntry 3 } fileTransfer OBJECT IDENTIFIER ::= { ne 14 } fileTransferTable OBJECT-TYPE SYNTAX SEQUENCE OF FileTransferEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { fileTransfer 1 } fileTransferEntry OBJECT-TYPE SYNTAX FileTransferEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of fileTransferTable" INDEX { multishelfFileManagementShelfId } ::= { fileTransferTable 1 } FileTransferEntry ::= SEQUENCE { fileTransferAction INTEGER, fileTransferLocalFilePath OCTET STRING, fileTransferRemoteFilePath OCTET STRING, fileTransferResult INTEGER, fileTransferResultMsg OCTET STRING, fileTransferExeResult INTEGER, fileTransferExeResultMsg OCTET STRING } fileTransferAction OBJECT-TYPE SYNTAX INTEGER { upload (1), download (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { fileTransferEntry 1 } fileTransferLocalFilePath OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { fileTransferEntry 2 } fileTransferRemoteFilePath OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { fileTransferEntry 3 } fileTransferResult OBJECT-TYPE SYNTAX INTEGER { successful (0), failed (1), unknown (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { fileTransferEntry 4 } fileTransferResultMsg OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..511)) MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { fileTransferEntry 5 } fileTransferExeResult OBJECT-TYPE SYNTAX INTEGER { successful (0), failed (1), unknown (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { fileTransferEntry 6 } fileTransferExeResultMsg OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..511)) MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { fileTransferEntry 7 } multishelfSwManagement OBJECT IDENTIFIER ::= { ne 15 } multishelfSwManagementTable OBJECT-TYPE SYNTAX SEQUENCE OF MultishelfSwManagementEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "multishelf-sw-management YANG models" ::= { multishelfSwManagement 1 } multishelfSwManagementEntry OBJECT-TYPE SYNTAX MultishelfSwManagementEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of multishelfSwManagementTable" INDEX { multishelfSwManagementShelfId } ::= { multishelfSwManagementTable 1 } MultishelfSwManagementEntry ::= SEQUENCE { multishelfSwManagementShelfId CoriantTypesShelfId } multishelfSwManagementShelfId OBJECT-TYPE SYNTAX CoriantTypesShelfId MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { multishelfSwManagementEntry 1 } swStageNotification OBJECT IDENTIFIER ::= { ne 16 } swStageNotificationTable OBJECT-TYPE SYNTAX SEQUENCE OF SwStageNotificationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { swStageNotification 1 } swStageNotificationEntry OBJECT-TYPE SYNTAX SwStageNotificationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of swStageNotificationTable" INDEX { multishelfSwManagementShelfId } ::= { swStageNotificationTable 1 } SwStageNotificationEntry ::= SEQUENCE { swStageNotificationStatus INTEGER, swStageNotificationStatusMessage OCTET STRING, swStageNotificationStageState INTEGER } swStageNotificationStatus OBJECT-TYPE SYNTAX INTEGER { successful (1), failed (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Successful or Failed " ::= { swStageNotificationEntry 1 } swStageNotificationStatusMessage OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "Gives a more detailed status " ::= { swStageNotificationEntry 2 } swStageNotificationStageState OBJECT-TYPE SYNTAX INTEGER { default (0), staging (1), staged (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { swStageNotificationEntry 3 } swActivateNotification OBJECT IDENTIFIER ::= { ne 17 } swActivateNotificationTable OBJECT-TYPE SYNTAX SEQUENCE OF SwActivateNotificationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { swActivateNotification 1 } swActivateNotificationEntry OBJECT-TYPE SYNTAX SwActivateNotificationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of swActivateNotificationTable" INDEX { multishelfSwManagementShelfId } ::= { swActivateNotificationTable 1 } SwActivateNotificationEntry ::= SEQUENCE { swActivateNotificationActivateNotificationType INTEGER, swActivateNotificationStatus INTEGER, swActivateNotificationStatusMessage OCTET STRING, swActivateNotificationActivateState INTEGER, swActivateNotificationUpgradeResult INTEGER } swActivateNotificationActivateNotificationType OBJECT-TYPE SYNTAX INTEGER { activate (1), commit (2), cancel (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Successful or Failed " ::= { swActivateNotificationEntry 1 } swActivateNotificationStatus OBJECT-TYPE SYNTAX INTEGER { successful (1), failed (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Successful or Failed " ::= { swActivateNotificationEntry 2 } swActivateNotificationStatusMessage OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "Gives a more detailed status " ::= { swActivateNotificationEntry 3 } swActivateNotificationActivateState OBJECT-TYPE SYNTAX INTEGER { default (0), beforeReset (1), afterReset (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { swActivateNotificationEntry 4 } swActivateNotificationUpgradeResult OBJECT-TYPE SYNTAX INTEGER { default (0), successful (1), failed (2), rollback (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { swActivateNotificationEntry 5 } multishelfDiscovery OBJECT IDENTIFIER ::= { ne 18 } multishelfDiscoveryTable OBJECT-TYPE SYNTAX SEQUENCE OF MultishelfDiscoveryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { multishelfDiscovery 1 } multishelfDiscoveryEntry OBJECT-TYPE SYNTAX MultishelfDiscoveryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of multishelfDiscoveryTable" INDEX { multishelfDiscoveryShelfSerialNumber } ::= { multishelfDiscoveryTable 1 } MultishelfDiscoveryEntry ::= SEQUENCE { multishelfDiscoveryShelfSerialNumber OCTET STRING, multishelfDiscoveryShelfMacAddress OCTET STRING, multishelfDiscoveryShelfStatus INTEGER, multishelfDiscoveryShelfId CoriantTypesShelfId } multishelfDiscoveryShelfSerialNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "IP Address of device " ::= { multishelfDiscoveryEntry 1 } multishelfDiscoveryShelfMacAddress OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The MAC address of the shelf " ::= { multishelfDiscoveryEntry 2 } multishelfDiscoveryShelfStatus OBJECT-TYPE SYNTAX INTEGER { offline (0), online (1), shelfidallocating (2), waitdbready (3), idle (4), swupgrade (5), keepsilent (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { multishelfDiscoveryEntry 3 } multishelfDiscoveryShelfId OBJECT-TYPE SYNTAX CoriantTypesShelfId MAX-ACCESS read-only STATUS current DESCRIPTION " Identifier of the shelf after assigned by the system. " ::= { multishelfDiscoveryEntry 4 } capabilities OBJECT IDENTIFIER ::= { ne 19 } capabilitiesMaxDegrees OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max. number of degrees supported by device " ::= { capabilities 1 } capabilitiesMaxSrgs OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max. number of SRGs in an add/drop group " ::= { capabilities 2 } equipment OBJECT IDENTIFIER ::= { groove 3 } shelf OBJECT IDENTIFIER ::= { equipment 1 } shelfTable OBJECT-TYPE SYNTAX SEQUENCE OF ShelfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { shelf 1 } shelfEntry OBJECT-TYPE SYNTAX ShelfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of shelfTable" INDEX { shelfId } ::= { shelfTable 1 } ShelfEntry ::= SEQUENCE { shelfId CoriantTypesShelfId, shelfLocation OCTET STRING, shelfInletTemperature CoriantTypesTemperature, shelfOutletTemperature CoriantTypesTemperature, shelfAdminStatus INTEGER, shelfOperStatus INTEGER, shelfAvailStatus BITS, shelfAliasName OCTET STRING, shelfType OCTET STRING, shelfSerialNumber OCTET STRING } shelfId OBJECT-TYPE SYNTAX CoriantTypesShelfId MAX-ACCESS read-only STATUS current DESCRIPTION " Identifier of the shelf. It shall be an integer number and assigned implicitly by the system or setting through coder on the shelf. " ::= { shelfEntry 1 } shelfLocation OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the location of this particular shelf. " ::= { shelfEntry 2 } shelfInletTemperature OBJECT-TYPE SYNTAX CoriantTypesTemperature MAX-ACCESS read-only STATUS current DESCRIPTION "shelf inlet temperature " ::= { shelfEntry 3 } shelfOutletTemperature OBJECT-TYPE SYNTAX CoriantTypesTemperature MAX-ACCESS read-only STATUS current DESCRIPTION "shelf outlet temperature " ::= { shelfEntry 4 } shelfAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { shelfEntry 5 } shelfOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { shelfEntry 6 } shelfAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { shelfEntry 7 } shelfAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { shelfEntry 8 } shelfType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the shelf. " ::= { shelfEntry 9 } shelfSerialNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number of the shelf. " ::= { shelfEntry 13 } slot OBJECT IDENTIFIER ::= { equipment 2 } slotTable OBJECT-TYPE SYNTAX SEQUENCE OF SlotEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { slot 1 } slotEntry OBJECT-TYPE SYNTAX SlotEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of slotTable" INDEX { shelfId,slotId } ::= { slotTable 1 } SlotEntry ::= SEQUENCE { slotId CoriantTypesSlotId, slotActualCardType CoriantTypesEquipmentType, slotPossibleCardTypes OCTET STRING, slotAdminStatus INTEGER, slotOperStatus INTEGER, slotAvailStatus BITS, slotAliasName OCTET STRING } slotId OBJECT-TYPE SYNTAX CoriantTypesSlotId MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of the slot. It shall be an integer number and assigned implicitly by the system. " ::= { slotEntry 1 } slotActualCardType OBJECT-TYPE SYNTAX CoriantTypesEquipmentType MAX-ACCESS read-only STATUS current DESCRIPTION " Equipment type for each slot/subslot according to the actually equipping. Needs to be re-defined in the project specific model. default value :empty" ::= { slotEntry 2 } slotPossibleCardTypes OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION " Defined all the equipment types which can be installed on the slot/subslot. This is a leaf list, encode by some leafs. " ::= { slotEntry 3 } slotAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { slotEntry 4 } slotOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { slotEntry 5 } slotAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { slotEntry 6 } slotAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { slotEntry 7 } card OBJECT IDENTIFIER ::= { equipment 3 } cardTable OBJECT-TYPE SYNTAX SEQUENCE OF CardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Card is a container carried by a slot." ::= { card 1 } cardEntry OBJECT-TYPE SYNTAX CardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of cardTable" INDEX { shelfId,slotId } ::= { cardTable 1 } CardEntry ::= SEQUENCE { cardRequiredType CoriantTypesCardType, cardEquipmentName OCTET STRING, cardAdminStatus INTEGER, cardOperStatus INTEGER, cardAvailStatus BITS, cardAliasName OCTET STRING, cardFanSpeedRate CoriantTypesPercentage, cardSwitchingType INTEGER, cardTemperature CoriantTypesTemperature, cardMode INTEGER } cardRequiredType OBJECT-TYPE SYNTAX CoriantTypesCardType MAX-ACCESS read-only STATUS current DESCRIPTION " The attribute indicates the equipment type to identify the module. Needs to be re-defined in the project specific model. " ::= { cardEntry 1 } cardEquipmentName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION " The attribute indicates an additional field to identify the module. " ::= { cardEntry 2 } cardAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { cardEntry 3 } cardOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { cardEntry 4 } cardAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { cardEntry 5 } cardAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { cardEntry 6 } cardFanSpeedRate OBJECT-TYPE SYNTAX CoriantTypesPercentage MAX-ACCESS read-only STATUS current DESCRIPTION "The fan speed of percentage. Conditions:../required-type = 'FAN' " ::= { cardEntry 7 } cardSwitchingType OBJECT-TYPE SYNTAX INTEGER { otn (0), tdm (1), optical (2), packet (3), opticalRouter (4), amplifier (5), omd (6), cad (7), notApplicable (8), otnTransponder (9) } MAX-ACCESS read-only STATUS current DESCRIPTION "The traffic switching type of card. Conditions:(../required-type != 'FAN') and (../required-type != 'PSU') and (../required-type != 'FRCU') and (../required-type != 'VIR-SIM') default value :otn" ::= { cardEntry 8 } cardTemperature OBJECT-TYPE SYNTAX CoriantTypesTemperature MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the monitoring point. " ::= { cardEntry 9 } cardMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), normal (1), regen (2), mixFunction (3), greyMuxponder (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specify the card mode, e.g. normal or regen. default value :normal" ::= { cardEntry 10 } subslot OBJECT IDENTIFIER ::= { equipment 4 } subslotTable OBJECT-TYPE SYNTAX SEQUENCE OF SubslotEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { subslot 1 } subslotEntry OBJECT-TYPE SYNTAX SubslotEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of subslotTable" INDEX { shelfId,slotId,subslotId } ::= { subslotTable 1 } SubslotEntry ::= SEQUENCE { subslotId CoriantTypesSlotId, subslotActualCardType CoriantTypesEquipmentType, subslotPossibleCardTypes OCTET STRING, subslotAdminStatus INTEGER, subslotOperStatus INTEGER, subslotAvailStatus BITS, subslotAliasName OCTET STRING } subslotId OBJECT-TYPE SYNTAX CoriantTypesSlotId MAX-ACCESS read-only STATUS current DESCRIPTION " Identifier of the subslot. " ::= { subslotEntry 1 } subslotActualCardType OBJECT-TYPE SYNTAX CoriantTypesEquipmentType MAX-ACCESS read-only STATUS current DESCRIPTION " Equipment type for each slot/subslot according to the actually equipping. Needs to be re-defined in the project specific model. default value :empty" ::= { subslotEntry 2 } subslotPossibleCardTypes OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION " Defined all the equipment types which can be installed on the slot/subslot. This is a leaf list, encode by some leafs. " ::= { subslotEntry 3 } subslotAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { subslotEntry 4 } subslotOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { subslotEntry 5 } subslotAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { subslotEntry 6 } subslotAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { subslotEntry 7 } subcard OBJECT IDENTIFIER ::= { equipment 5 } subcardTable OBJECT-TYPE SYNTAX SEQUENCE OF SubcardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Subcard is a container carried by a subslot." ::= { subcard 1 } subcardEntry OBJECT-TYPE SYNTAX SubcardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of subcardTable" INDEX { shelfId,slotId,subslotId } ::= { subcardTable 1 } SubcardEntry ::= SEQUENCE { subcardRequiredType CoriantTypesCardType, subcardEquipmentName OCTET STRING, subcardAdminStatus INTEGER, subcardOperStatus INTEGER, subcardAvailStatus BITS, subcardAliasName OCTET STRING, subcardTemperature CoriantTypesTemperature, subcardSwitchingType INTEGER } subcardRequiredType OBJECT-TYPE SYNTAX CoriantTypesCardType MAX-ACCESS read-only STATUS current DESCRIPTION " The attribute indicates the equipment type to identify the module. Needs to be re-defined in the project specific model. " ::= { subcardEntry 1 } subcardEquipmentName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION " The attribute indicates an additional field to identify the module. " ::= { subcardEntry 2 } subcardAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { subcardEntry 3 } subcardOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { subcardEntry 4 } subcardAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { subcardEntry 5 } subcardAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { subcardEntry 6 } subcardTemperature OBJECT-TYPE SYNTAX CoriantTypesTemperature MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the monitoring point. " ::= { subcardEntry 7 } subcardSwitchingType OBJECT-TYPE SYNTAX INTEGER { otn (0), tdm (1), optical (2), packet (3), opticalRouter (4), amplifier (5), omd (6), cad (7), notApplicable (8), otnTransponder (9) } MAX-ACCESS read-only STATUS current DESCRIPTION "The traffic switching type of card. Conditions:(../required-type != 'FAN') and (../required-type != 'PSU') and (../required-type != 'FRCU') and (../required-type != 'VIR-SIM') default value :otn" ::= { subcardEntry 11 } port OBJECT IDENTIFIER ::= { equipment 6 } portTable OBJECT-TYPE SYNTAX SEQUENCE OF PortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { port 1 } portEntry OBJECT-TYPE SYNTAX PortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of portTable" INDEX { shelfId,slotId,subslotId,portId } ::= { portTable 1 } PortEntry ::= SEQUENCE { portId CoriantTypesPortId, portPossiblePluggableTypes OCTET STRING, portActualPluggableType CoriantTypesEquipmentType, portRxOpticalPower CoriantTypesOpticalPower, portTxOpticalPower CoriantTypesOpticalPower, portRxOpticalPowerSelectedChannel CoriantTypesOpticalPower, portDirectionType CoriantTypesTypeOfDirection, portName CoriantTypesNameIdentifier, portType INTEGER, portMode CoriantTypesPortMode, portAdminStatus INTEGER, portOperStatus INTEGER, portAvailStatus BITS, portAliasName OCTET STRING, portServiceLabel OCTET STRING, portConnectedTo OCTET STRING, portArcConfig INTEGER, portArcState INTEGER, portArcSubState INTEGER, portArcTimer Unsigned32, portArcRemainingTime OCTET STRING, portExternalConnectivity CoriantTypesYesNo } portId OBJECT-TYPE SYNTAX CoriantTypesPortId MAX-ACCESS read-only STATUS current DESCRIPTION "The identifier is defined to uniquely identify the port. " ::= { portEntry 1 } portPossiblePluggableTypes OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION " Defined all the pluggable types which can be equipped on the port. Needs to be re-defined in the project specific model. This is a leaf list, encode by some leafs. Conditions:(../port-type != 'optical') and (../port-type != 'otdr') and (../port-type != 'optical-nomon') and (../port-type != 'ocm') and (../port-type != 'mgmt-eth') " ::= { portEntry 2 } portActualPluggableType OBJECT-TYPE SYNTAX CoriantTypesEquipmentType MAX-ACCESS read-only STATUS current DESCRIPTION " Pluggable type for each port according to the actually equipping. Needs to be re-defined in the project specific model. Conditions:(../port-type != 'optical') and (../port-type != 'ocm') and (../port-type != 'optical-nomon') and (../port-type != 'otdr') and (../port-type != 'mgmt-eth') default value :empty" ::= { portEntry 3 } portRxOpticalPower OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "Received optical power " ::= { portEntry 4 } portTxOpticalPower OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "Transmitted optical power " ::= { portEntry 5 } portRxOpticalPowerSelectedChannel OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "Optical power of the selected channel on coherent receiver, which will be different from the rx-optical-power when multiple channels input simultaneously. " ::= { portEntry 6 } portDirectionType OBJECT-TYPE SYNTAX CoriantTypesTypeOfDirection MAX-ACCESS read-only STATUS current DESCRIPTION "Supported direction of the optical port. " ::= { portEntry 15 } portName OBJECT-TYPE SYNTAX CoriantTypesNameIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the port. default value :unspecified" ::= { portEntry 16 } portType OBJECT-TYPE SYNTAX INTEGER { client (1), line (2), clientSubport (3), optical (4), otdr (5), opticalNomon (6), ocm (7), osc (8), mgmtEth (9) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of port. Needs to be provided upon Port creation default value :optical-nomon" ::= { portEntry 17 } portMode OBJECT-TYPE SYNTAX CoriantTypesPortMode MAX-ACCESS read-only STATUS current DESCRIPTION " The working mode of port. For client side: CHM1: applicable to port 3 to 6; possible values are: 100GBE, not-applicable. Default is 100GBE when card created. CHM2: applicable to port 3 to 11; possible values are: 40GBE, subport, not-applicable; applicable to subport 1 to 4; possible values are: 10GBE, not-applicable. Default is not-applicable. For Line side: CHM1/CHM2: possible values are: QPSK_100G, 16QAM_200G, 8QAM_300G. Default is 16QAM_200G. non applicable : there shall not be service created on the port or subport subport: the port shall create four subports under the port to support 4x10G. 40GBE: 40GBE service shall be created on the port with default mapping GMP. 10GBE: 10GBE service shall be created on the subport with default mapping BMP with fixed stuff. 100GBE: 100GBE service shall be created on the subport with default mapping GMP. QPSK_100G: 100G OTU4 service with DP-QPSK coherent modulation format shall be created on the port. 16QAM_200G: 200G OTUC2 service with DP-16QAM coherent modulation format shall be created on the port. 8QAM_300G: 300G OTUC3 service with DP-8QAM coherent modulation format shall be created on the coupled two line ports. Note 4x10G is to create subport managed objects under the port. Each subport can support a 10G service. Restrictions: Changing Port mode shall be allowed only if the impacted port or subport object is administratively down. Changing a 'subport' port mode of a port to be other value shall only be allowed only if port-modes of all the subports under the port are 'not-applicable'. If there is explicitly cross-connection is created associated with the ODU of the port, change port mode of the port shall be denied. If the port mode is a coupled port mode, e.g. 8QAM_300G, port mode can only be edited on the lower number of port within the coupled ports. The other port (or ports if more than two) will have read-only port mode value same as this lowest number port. When port/subport is set to admin down, laser will be shutdown, ingress side will insert proper maintenance signal. Conditions:(../port-type = 'line') or (../port-type = 'client') or (../port-type = 'client-subport') default value :not-applicable" ::= { portEntry 18 } portAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { portEntry 19 } portOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { portEntry 20 } portAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { portEntry 21 } portAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { portEntry 22 } portServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { portEntry 23 } portConnectedTo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate neighbour port/facility entity to which the current port/facility is connected to. " ::= { portEntry 24 } portArcConfig OBJECT-TYPE SYNTAX INTEGER { alm (1), nalmQi (2), nalm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The configurable mode of the Alarm Report Control (ARC). default value :nalm-qi" ::= { portEntry 25 } portArcState OBJECT-TYPE SYNTAX INTEGER { alm (1), nalmQi (2), nalm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The current mode of the Alarm Report Control (ARC). default value :nalm-qi" ::= { portEntry 26 } portArcSubState OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), nalmCd (1), nalmNr (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " Additional information about the Alarm Report Control (ARC) when the main state is in the NALM-QI state default value :nalm-nr" ::= { portEntry 27 } portArcTimer OBJECT-TYPE SYNTAX Unsigned32 (0..10080) MAX-ACCESS read-only STATUS current DESCRIPTION "The holdoff timer value in minutes of the ARC. Range is 0 - 10080 minutes UNITS:minutes default value :1440" ::= { portEntry 28 } portArcRemainingTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION " The remaining timer value (format: xxd-xxh:xxm:xxs) before the alarm is reported. default value :00d-00h:00m:00s" ::= { portEntry 29 } portExternalConnectivity OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the port is connected externally or not. default value :no" ::= { portEntry 30 } subport OBJECT IDENTIFIER ::= { equipment 7 } subportTable OBJECT-TYPE SYNTAX SEQUENCE OF SubportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { subport 1 } subportEntry OBJECT-TYPE SYNTAX SubportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of subportTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { subportTable 1 } SubportEntry ::= SEQUENCE { subportId CoriantTypesPortId, subportPortName CoriantTypesNameIdentifier, subportPortType INTEGER, subportPortMode CoriantTypesPortMode, subportAdminStatus INTEGER, subportOperStatus INTEGER, subportAvailStatus BITS, subportAliasName OCTET STRING, subportServiceLabel OCTET STRING, subportConnectedTo OCTET STRING, subportArcConfig INTEGER, subportArcState INTEGER, subportArcSubState INTEGER, subportArcTimer Unsigned32, subportArcRemainingTime OCTET STRING, subportRxOpticalPower CoriantTypesOpticalPower, subportTxOpticalPower CoriantTypesOpticalPower, subportExternalConnectivity CoriantTypesYesNo, subportDirectionType CoriantTypesTypeOfDirection } subportId OBJECT-TYPE SYNTAX CoriantTypesPortId MAX-ACCESS read-only STATUS current DESCRIPTION "The identifier is defined to uniquely identify the subport. " ::= { subportEntry 1 } subportPortName OBJECT-TYPE SYNTAX CoriantTypesNameIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the port. default value :unspecified" ::= { subportEntry 2 } subportPortType OBJECT-TYPE SYNTAX INTEGER { client (1), line (2), clientSubport (3), optical (4), otdr (5), opticalNomon (6), ocm (7), osc (8), mgmtEth (9) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of port. Needs to be provided upon Port creation default value :optical-nomon" ::= { subportEntry 3 } subportPortMode OBJECT-TYPE SYNTAX CoriantTypesPortMode MAX-ACCESS read-only STATUS current DESCRIPTION " The working mode of port. For client side: CHM1: applicable to port 3 to 6; possible values are: 100GBE, not-applicable. Default is 100GBE when card created. CHM2: applicable to port 3 to 11; possible values are: 40GBE, subport, not-applicable; applicable to subport 1 to 4; possible values are: 10GBE, not-applicable. Default is not-applicable. For Line side: CHM1/CHM2: possible values are: QPSK_100G, 16QAM_200G, 8QAM_300G. Default is 16QAM_200G. non applicable : there shall not be service created on the port or subport subport: the port shall create four subports under the port to support 4x10G. 40GBE: 40GBE service shall be created on the port with default mapping GMP. 10GBE: 10GBE service shall be created on the subport with default mapping BMP with fixed stuff. 100GBE: 100GBE service shall be created on the subport with default mapping GMP. QPSK_100G: 100G OTU4 service with DP-QPSK coherent modulation format shall be created on the port. 16QAM_200G: 200G OTUC2 service with DP-16QAM coherent modulation format shall be created on the port. 8QAM_300G: 300G OTUC3 service with DP-8QAM coherent modulation format shall be created on the coupled two line ports. Note 4x10G is to create subport managed objects under the port. Each subport can support a 10G service. Restrictions: Changing Port mode shall be allowed only if the impacted port or subport object is administratively down. Changing a 'subport' port mode of a port to be other value shall only be allowed only if port-modes of all the subports under the port are 'not-applicable'. If there is explicitly cross-connection is created associated with the ODU of the port, change port mode of the port shall be denied. If the port mode is a coupled port mode, e.g. 8QAM_300G, port mode can only be edited on the lower number of port within the coupled ports. The other port (or ports if more than two) will have read-only port mode value same as this lowest number port. When port/subport is set to admin down, laser will be shutdown, ingress side will insert proper maintenance signal. Conditions:(../port-type = 'line') or (../port-type = 'client') or (../port-type = 'client-subport') default value :not-applicable" ::= { subportEntry 4 } subportAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { subportEntry 5 } subportOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { subportEntry 6 } subportAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { subportEntry 7 } subportAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { subportEntry 8 } subportServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { subportEntry 9 } subportConnectedTo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate neighbour port/facility entity to which the current port/facility is connected to. " ::= { subportEntry 10 } subportArcConfig OBJECT-TYPE SYNTAX INTEGER { alm (1), nalmQi (2), nalm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The configurable mode of the Alarm Report Control (ARC). default value :nalm-qi" ::= { subportEntry 11 } subportArcState OBJECT-TYPE SYNTAX INTEGER { alm (1), nalmQi (2), nalm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The current mode of the Alarm Report Control (ARC). default value :nalm-qi" ::= { subportEntry 12 } subportArcSubState OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), nalmCd (1), nalmNr (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " Additional information about the Alarm Report Control (ARC) when the main state is in the NALM-QI state default value :nalm-nr" ::= { subportEntry 13 } subportArcTimer OBJECT-TYPE SYNTAX Unsigned32 (0..10080) MAX-ACCESS read-only STATUS current DESCRIPTION "The holdoff timer value in minutes of the ARC. Range is 0 - 10080 minutes UNITS:minutes default value :1440" ::= { subportEntry 14 } subportArcRemainingTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION " The remaining timer value (format: xxd-xxh:xxm:xxs) before the alarm is reported. default value :00d-00h:00m:00s" ::= { subportEntry 15 } subportRxOpticalPower OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "Received optical power " ::= { subportEntry 16 } subportTxOpticalPower OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "Transmitted optical power " ::= { subportEntry 17 } subportExternalConnectivity OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the port is connected externally or not. default value :no" ::= { subportEntry 18 } subportDirectionType OBJECT-TYPE SYNTAX CoriantTypesTypeOfDirection MAX-ACCESS read-only STATUS current DESCRIPTION "Supported direction of the optical port. " ::= { subportEntry 19 } pluggable OBJECT IDENTIFIER ::= { equipment 8 } pluggableTable OBJECT-TYPE SYNTAX SEQUENCE OF PluggableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the Pluggable object" ::= { pluggable 1 } pluggableEntry OBJECT-TYPE SYNTAX PluggableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of pluggableTable" INDEX { shelfId,slotId,subslotId,portId } ::= { pluggableTable 1 } PluggableEntry ::= SEQUENCE { pluggableRequiredType CoriantTypesPluggableType, pluggableFormFactor CoriantTypesPluggableFormFactor, pluggableInterfaceType OCTET STRING, pluggableLaserSource INTEGER, pluggableHwVersion OCTET STRING, pluggableVendor OCTET STRING, pluggableSerialNumber OCTET STRING, pluggableFwVersion OCTET STRING, pluggablePartNumber OCTET STRING, pluggableClei OCTET STRING, pluggableEquipmentName OCTET STRING, pluggableAdminStatus INTEGER, pluggableOperStatus INTEGER, pluggableAvailStatus BITS, pluggableAliasName OCTET STRING, pluggableTemperature CoriantTypesTemperature, pluggableVoltage OCTET STRING } pluggableRequiredType OBJECT-TYPE SYNTAX CoriantTypesPluggableType MAX-ACCESS read-only STATUS current DESCRIPTION " The attribute indicates the equipment type to identify the module. Needs to be re-defined in the project specific model. " ::= { pluggableEntry 1 } pluggableFormFactor OBJECT-TYPE SYNTAX CoriantTypesPluggableFormFactor MAX-ACCESS read-only STATUS current DESCRIPTION "Indicating the exact form factor of the pluggable. default value :Unrecognized" ::= { pluggableEntry 2 } pluggableInterfaceType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicating interface type of the pluggable. default value :" ::= { pluggableEntry 3 } pluggableLaserSource OBJECT-TYPE SYNTAX INTEGER { txLoShared (1), txLoIndependent (2), notAvailable (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The type of laser frequency. Only tx-lo-independent type support och-os rx-frequency working Conditions:../required-type = 'CFP2' default value :not-available" ::= { pluggableEntry 4 } pluggableHwVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION " The attribute Identifies the Hardware Version of the module that populates the slot. " ::= { pluggableEntry 5 } pluggableVendor OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION " Vendor information. " ::= { pluggableEntry 6 } pluggableSerialNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..18)) MAX-ACCESS read-only STATUS current DESCRIPTION " This is the value of serial number stored in EEPROM of the equipment. " ::= { pluggableEntry 7 } pluggableFwVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION " Current Firmware (FW) version on the equipment. " ::= { pluggableEntry 8 } pluggablePartNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..18)) MAX-ACCESS read-only STATUS current DESCRIPTION " Identifies the Part Number of the equipment. " ::= { pluggableEntry 9 } pluggableClei OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..18)) MAX-ACCESS read-only STATUS current DESCRIPTION " Identifies the CLEI code number of the equipment. The CLEI code is a 10-character code that identifies communications equipment. It describes product type, features, source document, and associated drawings and vintages. " ::= { pluggableEntry 10 } pluggableEquipmentName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION " The attribute indicates an additional field to identify the module. " ::= { pluggableEntry 11 } pluggableAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { pluggableEntry 12 } pluggableOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { pluggableEntry 13 } pluggableAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { pluggableEntry 14 } pluggableAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { pluggableEntry 15 } pluggableTemperature OBJECT-TYPE SYNTAX CoriantTypesTemperature MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the monitoring point. " ::= { pluggableEntry 16 } pluggableVoltage OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION " The current voltage applied by the module. The current is expressed in V with up to two decimal precision. Just supply the instant value. UNITS:V " ::= { pluggableEntry 17 } amplifier OBJECT IDENTIFIER ::= { equipment 9 } amplifierTable OBJECT-TYPE SYNTAX SEQUENCE OF AmplifierEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The list of optical amplifier on an equipment." ::= { amplifier 1 } amplifierEntry OBJECT-TYPE SYNTAX AmplifierEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of amplifierTable" INDEX { shelfId,slotId,subslotId,amplifierName } ::= { amplifierTable 1 } AmplifierEntry ::= SEQUENCE { amplifierName CoriantTypesNameIdentifier, amplifierSupportingInputPort RowPointer, amplifierSupportingOutputPort RowPointer, amplifierAdminStatus INTEGER, amplifierOperStatus INTEGER, amplifierAvailStatus BITS, amplifierAliasName OCTET STRING, amplifierEnable CoriantTypesEnableSwitch, amplifierInputLosShutdown CoriantTypesEnableSwitch, amplifierControlMode INTEGER, amplifierMode INTEGER, amplifierType INTEGER, amplifierTargetGain CoriantTypesOpticalDB, amplifierOperatingGain CoriantTypesOpticalDB, amplifierGainAdjustment CoriantTypesOpticalDB, amplifierOutputPowerMon CoriantTypesOpticalPower, amplifierOutputPowerMonWithAse CoriantTypesOpticalPower, amplifierInputPowerMon CoriantTypesOpticalPower, amplifierOutputVoa CoriantTypesOpticalDB, amplifierPowerBeforeOutputVoa CoriantTypesOpticalPower, amplifierGainTilt CoriantTypesOpticalDB, amplifierTiltControlMode INTEGER, amplifierActualGainTilt CoriantTypesOpticalDB, amplifierPumpStatus CoriantTypesEnableSwitch, amplifierGainRangeControl INTEGER, amplifierTargetGainRange AmplifierGainRangeType, amplifierWorkingGainRange AmplifierGainRangeType, amplifierActualOutputVoa CoriantTypesOpticalDB, amplifierPartnerAmp OCTET STRING, amplifierEgressAverageChannelPower CoriantTypesOpticalPower } amplifierName OBJECT-TYPE SYNTAX CoriantTypesNameIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "User-defined name assigned to identify a specific amplifier in the device " ::= { amplifierEntry 1 } amplifierSupportingInputPort OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of the supporting input port. " ::= { amplifierEntry 2 } amplifierSupportingOutputPort OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of the supporting output port. " ::= { amplifierEntry 3 } amplifierAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { amplifierEntry 4 } amplifierOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { amplifierEntry 5 } amplifierAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { amplifierEntry 6 } amplifierAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { amplifierEntry 7 } amplifierEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Configuration for enable or disable the amplifier. default value :disabled" ::= { amplifierEntry 8 } amplifierInputLosShutdown OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable the function of automatic shutdown per input LOS. default value :enabled" ::= { amplifierEntry 9 } amplifierControlMode OBJECT-TYPE SYNTAX INTEGER { manual (1), auto (2), autoMaxPw (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Control mode of the amplifier. default value :auto-max-pw" ::= { amplifierEntry 10 } amplifierMode OBJECT-TYPE SYNTAX INTEGER { constantPower (1), constantGain (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operating mode of the amplifier default value :constant-gain" ::= { amplifierEntry 11 } amplifierType OBJECT-TYPE SYNTAX INTEGER { fixedGainEdfa (1), variableGainEdfa (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the amplifier. default value :variable-gain-EDFA" ::= { amplifierEntry 12 } amplifierTargetGain OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION "Setting gain to the amplifier for constant-gain mode in manual control mode. " ::= { amplifierEntry 13 } amplifierOperatingGain OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION "Operating gain of the amplifier, which is the actually configured gain on the amplifier. " ::= { amplifierEntry 14 } amplifierGainAdjustment OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION "The value is used for adjustment of gain when the amplifier in automatic control mode, the automatically caculated gain will include offset of this attribute. default value :0.0" ::= { amplifierEntry 15 } amplifierOutputPowerMon OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "Monitored aggregation signal output power. UNITS:dBm " ::= { amplifierEntry 18 } amplifierOutputPowerMonWithAse OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "Monitored aggregation total output power including both signal and ASE. UNITS:dBm " ::= { amplifierEntry 19 } amplifierInputPowerMon OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "Monitored aggregation input power. UNITS:dBm " ::= { amplifierEntry 20 } amplifierOutputVoa OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION "Configurable optical attenuation at output of the amplifier. default value :0.0" ::= { amplifierEntry 21 } amplifierPowerBeforeOutputVoa OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "Monitored optical power after output VOA. UNITS:dBm " ::= { amplifierEntry 22 } amplifierGainTilt OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION "Specify gain tilt of the amplifier. default value :0.0" ::= { amplifierEntry 23 } amplifierTiltControlMode OBJECT-TYPE SYNTAX INTEGER { manual (1), auto (2), autoPlanned (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specify gain tilt control modes. default value :manual" ::= { amplifierEntry 24 } amplifierActualGainTilt OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION "Actually setting of gain tilt on the amplifier. default value :0.0" ::= { amplifierEntry 25 } amplifierPumpStatus OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The amplifier's pump working status, enable or disable default value :disabled" ::= { amplifierEntry 26 } amplifierGainRangeControl OBJECT-TYPE SYNTAX INTEGER { manual (1), auto (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The gain range working mode for multi gain range supported amplifier default value :auto" ::= { amplifierEntry 27 } amplifierTargetGainRange OBJECT-TYPE SYNTAX AmplifierGainRangeType MAX-ACCESS read-only STATUS current DESCRIPTION "The gain-range selected one for manual gain-range-mode default value :standard" ::= { amplifierEntry 28 } amplifierWorkingGainRange OBJECT-TYPE SYNTAX AmplifierGainRangeType MAX-ACCESS read-only STATUS current DESCRIPTION "The current working gain range default value :not-available" ::= { amplifierEntry 29 } amplifierActualOutputVoa OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION "Working optical attenuation at output of the amplifier. default value :0.0" ::= { amplifierEntry 30 } amplifierPartnerAmp OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The partner amplifier for in line amplifier working mode. default value :not-available" ::= { amplifierEntry 31 } amplifierEgressAverageChannelPower OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "Based upon the total max power across the 4.8 THz passband. Defined as optional for ODL support, but shall be considered as mandatory and provided by the controller when the control-mode is set to gainLoss for amplifier setting " ::= { amplifierEntry 32 } tdc OBJECT IDENTIFIER ::= { equipment 10 } tdcTable OBJECT-TYPE SYNTAX SEQUENCE OF TdcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The list of optical tdc on an equipment." ::= { tdc 1 } tdcEntry OBJECT-TYPE SYNTAX TdcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of tdcTable" INDEX { shelfId,slotId,subslotId,tdcName } ::= { tdcTable 1 } TdcEntry ::= SEQUENCE { tdcName CoriantTypesNameIdentifier, tdcSupportingInputPort RowPointer, tdcSupportingOutputPort RowPointer, tdcAdminStatus INTEGER, tdcOperStatus INTEGER, tdcAvailStatus BITS, tdcAliasName OCTET STRING, tdcMode INTEGER, tdcReferenceFrequency CoriantTypesFreq, tdcActualReferenceFrequency Unsigned32, tdcFrequencyRangeMin Unsigned32, tdcFrequencyRangeMax Unsigned32, tdcChromaticDispersion INTEGER, tdcChromaticDispersionAdjustment INTEGER, tdcActualChromaticDispersion INTEGER, tdcCdRangeMin INTEGER, tdcCdRangeMax INTEGER } tdcName OBJECT-TYPE SYNTAX CoriantTypesNameIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "User-defined name assigned to identify a specific tdc in the device " ::= { tdcEntry 1 } tdcSupportingInputPort OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of the supporting input port. " ::= { tdcEntry 2 } tdcSupportingOutputPort OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of the supporting output port. " ::= { tdcEntry 3 } tdcAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { tdcEntry 4 } tdcOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { tdcEntry 5 } tdcAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { tdcEntry 6 } tdcAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { tdcEntry 7 } tdcMode OBJECT-TYPE SYNTAX INTEGER { manual (1), auto (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Control mode of the tunable dispersion compensation; Manual: CD value will be decided per configured CD value; Auto: system will automatically decide the CD value per measured chromatic dispersion in the span. default value :auto" ::= { tdcEntry 8 } tdcReferenceFrequency OBJECT-TYPE SYNTAX CoriantTypesFreq MAX-ACCESS read-only STATUS current DESCRIPTION " Indicating the reference wavelength of the TDC. UNITS:MHz " ::= { tdcEntry 9 } tdcActualReferenceFrequency OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION " Indicating the actual reference wavelength of the TDC. UNITS:MHz " ::= { tdcEntry 10 } tdcFrequencyRangeMin OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum of supported wavelength. UNITS:MHz " ::= { tdcEntry 11 } tdcFrequencyRangeMax OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum of supported wavelength. UNITS:MHz " ::= { tdcEntry 12 } tdcChromaticDispersion OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The setting value of Chromatic Dispersion. UNITS:ps/nm default value :0" ::= { tdcEntry 13 } tdcChromaticDispersionAdjustment OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The value will be used to adjust target chromatic dispersion by adding the value with auto decided dispersion in auto tdc mode. UNITS:ps/nm " ::= { tdcEntry 14 } tdcActualChromaticDispersion OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The actual value of Chromatic Dispersion. UNITS:ps/nm " ::= { tdcEntry 15 } tdcCdRangeMin OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum of supported chromatic dispersion. UNITS:ps/nm " ::= { tdcEntry 16 } tdcCdRangeMax OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum of supported chromatic dispersion. UNITS:ps/nm " ::= { tdcEntry 17 } inventory OBJECT IDENTIFIER ::= { equipment 12 } inventoryTable OBJECT-TYPE SYNTAX SEQUENCE OF InventoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { inventory 1 } inventoryEntry OBJECT-TYPE SYNTAX InventoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of inventoryTable" INDEX { inventoryEquipmentType,inventoryShelfId,inventorySlotId,inventorySubslotId,inventoryPortId } ::= { inventoryTable 1 } InventoryEntry ::= SEQUENCE { inventoryEquipmentType INTEGER, inventoryShelfId CoriantTypesShelfId, inventorySlotId CoriantTypesSlotId, inventorySubslotId CoriantTypesSlotId, inventoryPortId CoriantTypesPortId, inventoryEquipmentVersion OCTET STRING, inventoryModuleType OCTET STRING, inventoryVendor OCTET STRING, inventorySerialNumber OCTET STRING, inventoryFwVersion OCTET STRING, inventoryPartNumber OCTET STRING, inventoryClei OCTET STRING, inventoryInterfaceType OCTET STRING, inventoryManufactureDate OCTET STRING, inventoryManufacturerNumber OCTET STRING } inventoryEquipmentType OBJECT-TYPE SYNTAX INTEGER { shelf (1), slot (2), card (3), port (4), pluggable (5), subslot (6), subcard (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The equipment type that the inventory data refers to " ::= { inventoryEntry 1 } inventoryShelfId OBJECT-TYPE SYNTAX CoriantTypesShelfId MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of the shelf. " ::= { inventoryEntry 2 } inventorySlotId OBJECT-TYPE SYNTAX CoriantTypesSlotId MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of the slot. " ::= { inventoryEntry 3 } inventorySubslotId OBJECT-TYPE SYNTAX CoriantTypesSlotId MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of the subslot. " ::= { inventoryEntry 4 } inventoryPortId OBJECT-TYPE SYNTAX CoriantTypesPortId MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of the port. " ::= { inventoryEntry 5 } inventoryEquipmentVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The attribute Identifies the Hardware Version of the module that populates the slot. " ::= { inventoryEntry 6 } inventoryModuleType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..18)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the value of module type stored in EEPROM of the equipment. " ::= { inventoryEntry 7 } inventoryVendor OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Vendor information. " ::= { inventoryEntry 8 } inventorySerialNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the value of serial number stored in EEPROM of the equipment. " ::= { inventoryEntry 9 } inventoryFwVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "Current Firmware (FW) version on the equipment. " ::= { inventoryEntry 10 } inventoryPartNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..18)) MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the Part Number of the equipment. " ::= { inventoryEntry 11 } inventoryClei OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..18)) MAX-ACCESS read-only STATUS current DESCRIPTION " Identifies the CLEI code number of the equipment. The CLEI code is a 10-character code that identifies communications equipment. It describes product type, features, source document, and associated drawings and vintages. CLEI codes have 4 data elements: - Characters 1 to 4: Define family or subfamily of product. - Characters 5 to 7: Define features. - Character 8: Manufacturer and System ID. - Characters 9 and 10: Identifies version, issue, and release #. " ::= { inventoryEntry 12 } inventoryInterfaceType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicating interface type of the pluggable. default value :" ::= { inventoryEntry 13 } inventoryManufactureDate OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The equipment manufacture date get from equipment. format is mm/dd/yyyy. When there is no date information show nothing Conditions:(../equipment-type = 'shelf') or (../equipment-type = 'card') or (../equipment-type = 'subcard') or (../equipment-type = 'pluggable') default value :" ::= { inventoryEntry 14 } inventoryManufacturerNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..18)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the value of manufacturer number stored in EEPROM of the equipment. " ::= { inventoryEntry 16 } led OBJECT IDENTIFIER ::= { equipment 14 } ledTable OBJECT-TYPE SYNTAX SEQUENCE OF LedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Attributes related with LED Applicable to Shelf, FAN, PSU, CHM1, CHM2, CHM1G, OCC2 in DCI. " ::= { led 1 } ledEntry OBJECT-TYPE SYNTAX LedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ledTable" INDEX { ledEquipmentType,ledShelfId,ledSlotId,ledSubslotId,ledName } ::= { ledTable 1 } LedEntry ::= SEQUENCE { ledEquipmentType OCTET STRING, ledShelfId CoriantTypesShelfId, ledSlotId CoriantTypesSlotId, ledName OCTET STRING, ledStatus INTEGER, ledSubslotId CoriantTypesSubslotId } ledEquipmentType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION " The attribute indicates the equipment type to identify the module. for example, if the card is CHM1, 'CHM1' shall be used. DCI supporting LEDs: CHM1, CHM2, SHELF, FAN " ::= { ledEntry 1 } ledShelfId OBJECT-TYPE SYNTAX CoriantTypesShelfId MAX-ACCESS read-only STATUS current DESCRIPTION " Identifier of the shelf. " ::= { ledEntry 2 } ledSlotId OBJECT-TYPE SYNTAX CoriantTypesSlotId MAX-ACCESS read-only STATUS current DESCRIPTION " Identifier of the slot. " ::= { ledEntry 3 } ledName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION " The functional name of LED. DCI NE: location_led port(n)_led (CHM1: n = 1 to 6, CHM2 n = 1 to 12, e.g. Port12) active_led power_led fault_led status_led subslot(n)_led " ::= { ledEntry 4 } ledStatus OBJECT-TYPE SYNTAX INTEGER { notAvailable (1), off (2), blink (3), red (4), redBlink (5), green (6), greenBlink (7), amber (8), amberBlink (9) } MAX-ACCESS read-only STATUS current DESCRIPTION " Current LED status. DCI NE: For Location_LED: OFF, BLINK For others: red, red-blink,green,green-blink,amber,amber-blink,off,notAvailable " ::= { ledEntry 5 } ledSubslotId OBJECT-TYPE SYNTAX CoriantTypesSubslotId MAX-ACCESS read-only STATUS current DESCRIPTION " Identifier of the subslot. " ::= { ledEntry 6 } temperatureDetails OBJECT IDENTIFIER ::= { equipment 15 } temperatureDetailsTable OBJECT-TYPE SYNTAX SEQUENCE OF TemperatureDetailsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The detailed information of temperature in each monitoring-point of current module" ::= { temperatureDetails 1 } temperatureDetailsEntry OBJECT-TYPE SYNTAX TemperatureDetailsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of temperatureDetailsTable" INDEX { shelfId,slotId,temperatureDetailsMonitoringPoint } ::= { temperatureDetailsTable 1 } TemperatureDetailsEntry ::= SEQUENCE { temperatureDetailsMonitoringPoint OCTET STRING, temperatureDetailsTemperature CoriantTypesTemperature, temperatureDetailsTemperatureRangeLow CoriantTypesTemperature, temperatureDetailsTemperatureRangeHigh CoriantTypesTemperature } temperatureDetailsMonitoringPoint OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The point of temperature monitoring. It could be the sensor or chip internal. " ::= { temperatureDetailsEntry 1 } temperatureDetailsTemperature OBJECT-TYPE SYNTAX CoriantTypesTemperature MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature at the monitoring point. " ::= { temperatureDetailsEntry 2 } temperatureDetailsTemperatureRangeLow OBJECT-TYPE SYNTAX CoriantTypesTemperature MAX-ACCESS read-only STATUS current DESCRIPTION "The lowest temperature threshold of this monitoring point in working mode. " ::= { temperatureDetailsEntry 3 } temperatureDetailsTemperatureRangeHigh OBJECT-TYPE SYNTAX CoriantTypesTemperature MAX-ACCESS read-only STATUS current DESCRIPTION "The highest temperature threshold of this monitoring point in working mode. " ::= { temperatureDetailsEntry 4 } otdr OBJECT IDENTIFIER ::= { equipment 16 } otdrTable OBJECT-TYPE SYNTAX SEQUENCE OF OtdrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Container of OTDR." ::= { otdr 1 } otdrEntry OBJECT-TYPE SYNTAX OtdrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otdrTable" INDEX { shelfId,slotId,subslotId } ::= { otdrTable 1 } OtdrEntry ::= SEQUENCE { otdrState INTEGER, otdrMeasurementTime Unsigned32, otdrError OCTET STRING, otdrLaserStatus INTEGER, otdrMeasurementPort Unsigned32 } otdrState OBJECT-TYPE SYNTAX INTEGER { notAvailable (0), idle (1), measuring (2), finished (3), fail (4) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicating the current status of the OTDR. default value :not-available" ::= { otdrEntry 1 } otdrMeasurementTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION " Indicating the time remaining in current measurement running. UNITS:second default value :0" ::= { otdrEntry 2 } otdrError OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Error message produced when the measurement ends with error. " ::= { otdrEntry 3 } otdrLaserStatus OBJECT-TYPE SYNTAX INTEGER { notAvailable (0), enabled (1), disabled (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicating the current status of the OTDR laser. default value :not-available" ::= { otdrEntry 4 } otdrMeasurementPort OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "0 indicates that the card is not measuring any port; non-zero indicates the OTDR port number where a measurement is currently taking place. default value :0" ::= { otdrEntry 5 } otdrPort OBJECT IDENTIFIER ::= { equipment 18 } otdrPortTable OBJECT-TYPE SYNTAX SEQUENCE OF OtdrPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Containing attributes of OTDR port." ::= { otdrPort 1 } otdrPortEntry OBJECT-TYPE SYNTAX OtdrPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otdrPortTable" INDEX { shelfId,slotId,subslotId,portId } ::= { otdrPortTable 1 } OtdrPortEntry ::= SEQUENCE { otdrPortOtdrRange OtdrOtdrRange, otdrPortOtdrPulseWidth OtdrOtdrPulseWidth, otdrPortOtdrMeasurementSpeed INTEGER, otdrPortOtdrIor OtdrOtdrIor, otdrPortOtdrFiberType INTEGER, otdrPortOtdrLastMeasurement IetfYangTypesDateAndTime, otdrPortOtdrResolution OCTET STRING, otdrPortLaunchingFiberLength OCTET STRING } otdrPortOtdrRange OBJECT-TYPE SYNTAX OtdrOtdrRange MAX-ACCESS read-only STATUS current DESCRIPTION " OTDR measurement range. UNITS:km default value :auto" ::= { otdrPortEntry 1 } otdrPortOtdrPulseWidth OBJECT-TYPE SYNTAX OtdrOtdrPulseWidth MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates pulse width to be used in otdr measurement. UNITS:nano-second default value :auto" ::= { otdrPortEntry 2 } otdrPortOtdrMeasurementSpeed OBJECT-TYPE SYNTAX INTEGER { fast (1), medium (3), slow (4), precision (5), auto (6), highPrecision (7) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicating OTDR measurement speed. default value :auto" ::= { otdrPortEntry 3 } otdrPortOtdrIor OBJECT-TYPE SYNTAX OtdrOtdrIor MAX-ACCESS read-only STATUS current DESCRIPTION " Specifies the group index of refraction (IOR) of the fiber to be measured. default value :auto" ::= { otdrPortEntry 4 } otdrPortOtdrFiberType OBJECT-TYPE SYNTAX INTEGER { unknown (0), ssmf (1), leaf (2), twrs (3), twc (4), allwave (5), dsf (6), ls (7), puresilica (8), twreach (9), vistacor (10), teralight (11), drakall (12), twplus (13), twminus (14), pslc (15), auto (16) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicating fiber type to be measured. default value :auto" ::= { otdrPortEntry 5 } otdrPortOtdrLastMeasurement OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the last otdr measurement date and time on the port. default value :0000-01-01T00:00:00.00Z" ::= { otdrPortEntry 6 } otdrPortOtdrResolution OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION " Specifies the OTDR data sampling resolution. UNITS:meter default value :auto" ::= { otdrPortEntry 7 } otdrPortLaunchingFiberLength OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The launching fiber length information for SOR to filter the launching fiber path data UNITS:km default value :0" ::= { otdrPortEntry 8 } ops OBJECT IDENTIFIER ::= { equipment 20 } opsTable OBJECT-TYPE SYNTAX SEQUENCE OF OpsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The list of optical protection switch (ops) on an equipment." ::= { ops 1 } opsEntry OBJECT-TYPE SYNTAX OpsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of opsTable" INDEX { shelfId,slotId,subslotId,opsName } ::= { opsTable 1 } OpsEntry ::= SEQUENCE { opsName CoriantTypesNameIdentifier, opsWorkingEntity RowPointer, opsProtectionEntity RowPointer, opsAdminStatus INTEGER, opsOperStatus INTEGER, opsAvailStatus BITS, opsAliasName OCTET STRING, opsProtectionStatus INTEGER, opsActivePath INTEGER, opsRevertive CoriantTypesYesNo, opsWaitToRestore Unsigned32, opsWorkingSwitchThreshold CoriantTypesOpticalPower, opsProtectionSwitchThreshold CoriantTypesOpticalPower, opsWorkingLosThreshold CoriantTypesOpticalPower, opsProtectionLosThreshold CoriantTypesOpticalPower, opsHoldoffTimer Unsigned32, opsWavelengthBand INTEGER, opsFrequency CoriantTypesFreq, opsWorkingProtectionRelativeThreshold CoriantTypesOpticalDB, opsRelativeThresholdHysteresis CoriantTypesOpticalDB, opsRelativeThresholdOffset CoriantTypesOpticalDB } opsName OBJECT-TYPE SYNTAX CoriantTypesNameIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "The name assigned to identify a specific ops in the device " ::= { opsEntry 1 } opsWorkingEntity OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of the working port of the OPS. " ::= { opsEntry 2 } opsProtectionEntity OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of the protection port of the OPS " ::= { opsEntry 3 } opsAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { opsEntry 4 } opsOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { opsEntry 5 } opsAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { opsEntry 6 } opsAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { opsEntry 7 } opsProtectionStatus OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), manualSwitchToProtection (1), manualSwitchToWorking (2), forceSwitchToProtection (3), forceSwitchToWorking (4), lockoutOfProtection (5), signalFailureOnWorking (6), signalFailureOnProtection (7), signalDegradeOnWorking (8), signalDegradeOnProtection (9), doNotRevert (10), noRequest (11), waitToRestore (12) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the status of the protection switch. " ::= { opsEntry 8 } opsActivePath OBJECT-TYPE SYNTAX INTEGER { working (1), protection (2), unknown (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicating the active port of the protection switch. default value :unknown" ::= { opsEntry 9 } opsRevertive OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Revertive behavior of the aps. If True, then automatically revert after protection switch once the fault is restored. default value :no" ::= { opsEntry 10 } opsWaitToRestore OBJECT-TYPE SYNTAX Unsigned32 (0..3600) MAX-ACCESS read-only STATUS current DESCRIPTION "Wait To Restore, valid values: 0-3600 seconds. A value of zero will switch back immediately, after expiration of the timer, the working is restored and a norequest state is transmitted. UNITS:second default value :300" ::= { opsEntry 11 } opsWorkingSwitchThreshold OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "The switching threshold of the working port which indicates the optical power threshold of signal degrade. default value :-18.0" ::= { opsEntry 12 } opsProtectionSwitchThreshold OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "The switching threshold of the protection port which indicates the optical power threshold of signal degrade. default value :-18.0" ::= { opsEntry 13 } opsWorkingLosThreshold OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "The switching threshold of the working port, power level below it will lead to loss of signal. default value :-23.0" ::= { opsEntry 14 } opsProtectionLosThreshold OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "The switching threshold of the protection port, power level below it will lead to loss of signal. default value :-23.0" ::= { opsEntry 15 } opsHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION " The hold off time of the protection switch. UNITS:milliseconds default value :0" ::= { opsEntry 16 } opsWavelengthBand OBJECT-TYPE SYNTAX INTEGER { t1550 (1), t1310 (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the band of the signal going through the optical protection switch unit. UNITS:nm default value :1550" ::= { opsEntry 17 } opsFrequency OBJECT-TYPE SYNTAX CoriantTypesFreq MAX-ACCESS read-only STATUS current DESCRIPTION " The frequency of optical protection frequency, which will decide the pilot tone modulated on the channel. UNITS:MHz default value :0" ::= { opsEntry 18 } opsWorkingProtectionRelativeThreshold OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION " Specify the threshold of power difference between working path and protection path; Setting to value 0 to disable the power difference as switch criteria; Setting to non-zero value indicates the value of power difference between two paths will trigger protection switch. default value :0" ::= { opsEntry 19 } opsRelativeThresholdHysteresis OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION " Specify relative threshold hysteresis for clearance of relative threshold crossing failure. default value :2.0" ::= { opsEntry 20 } opsRelativeThresholdOffset OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION " Specify relative threshold offset for protection switch per power difference between working and protection, the offset is the value of (working power - protection power), the offset value will be excluded from power difference before comparing to relative threshold threshold and its hysteresis. default value :0.0" ::= { opsEntry 21 } subportStatistics OBJECT IDENTIFIER ::= { equipment 25 } subportStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF SubportStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { subportStatistics 1 } subportStatisticsEntry OBJECT-TYPE SYNTAX SubportStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of subportStatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { subportStatisticsTable 1 } SubportStatisticsEntry ::= SEQUENCE { subportStatisticsEntryLastClear IetfYangTypesDateAndTime } subportStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { subportStatisticsEntry 1 } portStatistics OBJECT IDENTIFIER ::= { equipment 26 } portStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF PortStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { portStatistics 1 } portStatisticsEntry OBJECT-TYPE SYNTAX PortStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of portStatisticsTable" INDEX { shelfId,slotId,subslotId,portId } ::= { portStatisticsTable 1 } PortStatisticsEntry ::= SEQUENCE { portStatisticsEntryLastClear IetfYangTypesDateAndTime } portStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { portStatisticsEntry 1 } subcardStatistics OBJECT IDENTIFIER ::= { equipment 27 } subcardStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF SubcardStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { subcardStatistics 1 } subcardStatisticsEntry OBJECT-TYPE SYNTAX SubcardStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of subcardStatisticsTable" INDEX { shelfId,slotId,subslotId } ::= { subcardStatisticsTable 1 } SubcardStatisticsEntry ::= SEQUENCE { subcardStatisticsEntryLastClear IetfYangTypesDateAndTime } subcardStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { subcardStatisticsEntry 1 } cardStatistics OBJECT IDENTIFIER ::= { equipment 28 } cardStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF CardStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { cardStatistics 1 } cardStatisticsEntry OBJECT-TYPE SYNTAX CardStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of cardStatisticsTable" INDEX { shelfId,slotId } ::= { cardStatisticsTable 1 } CardStatisticsEntry ::= SEQUENCE { cardStatisticsEntryLastClear IetfYangTypesDateAndTime } cardStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { cardStatisticsEntry 1 } shelfStatistics OBJECT IDENTIFIER ::= { equipment 29 } shelfStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF ShelfStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { shelfStatistics 1 } shelfStatisticsEntry OBJECT-TYPE SYNTAX ShelfStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of shelfStatisticsTable" INDEX { shelfId } ::= { shelfStatisticsTable 1 } ShelfStatisticsEntry ::= SEQUENCE { shelfStatisticsEntryLastClear IetfYangTypesDateAndTime } shelfStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { shelfStatisticsEntry 1 } ocmPort OBJECT IDENTIFIER ::= { equipment 30 } ocmPortTable OBJECT-TYPE SYNTAX SEQUENCE OF OcmPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Containing attributes of OCM port." ::= { ocmPort 1 } ocmPortEntry OBJECT-TYPE SYNTAX OcmPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ocmPortTable" INDEX { shelfId,slotId,subslotId,portId } ::= { ocmPortTable 1 } OcmPortEntry ::= SEQUENCE { ocmPortEnable CoriantTypesEnableSwitch, ocmPortGridMode CoriantTypesGridType, ocmPortOpticalPowerOffset CoriantTypesOpticalDB, ocmPortChannelBaudRate INTEGER, ocmPortPpa1dBBW Unsigned32 } ocmPortEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable the function of ocm port measurement. default value :disabled" ::= { ocmPortEntry 1 } ocmPortGridMode OBJECT-TYPE SYNTAX CoriantTypesGridType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates Grid type of the OMS. default value :fixed_50G_96ch" ::= { ocmPortEntry 2 } ocmPortOpticalPowerOffset OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION "The offset to calibrate Optical power of monitored channels, resulted value = monitored value + offset. " ::= { ocmPortEntry 4 } ocmPortChannelBaudRate OBJECT-TYPE SYNTAX INTEGER { low (1), high (2), userDefined (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The baud rate selection for monitored optical channel default value :user-defined" ::= { ocmPortEntry 5 } ocmPortPpa1dBBW OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The channel baud rate with 1dB bandwidth working for user-defined channel-baud-rate UNITS:GHz " ::= { ocmPortEntry 6 } monitoredChannels OBJECT IDENTIFIER ::= { equipment 31 } monitoredChannelsTable OBJECT-TYPE SYNTAX SEQUENCE OF MonitoredChannelsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of monitored channels" ::= { monitoredChannels 1 } monitoredChannelsEntry OBJECT-TYPE SYNTAX MonitoredChannelsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of monitoredChannelsTable" INDEX { shelfId,slotId,subslotId,portId,monitoredChannelsFrequencyIndex } ::= { monitoredChannelsTable 1 } MonitoredChannelsEntry ::= SEQUENCE { monitoredChannelsFrequencyIndex CoriantTypesFreq, monitoredChannelsMonitoredCenterFrequency CoriantTypesFreq, monitoredChannelsMonitoredOpticalPower CoriantTypesOpticalPower, monitoredChannelsMonitoredWidth CoriantTypesFreqRoadm } monitoredChannelsFrequencyIndex OBJECT-TYPE SYNTAX CoriantTypesFreq MAX-ACCESS read-only STATUS current DESCRIPTION "Nominal center frequency as index with unit of MHz. " ::= { monitoredChannelsEntry 1 } monitoredChannelsMonitoredCenterFrequency OBJECT-TYPE SYNTAX CoriantTypesFreq MAX-ACCESS read-only STATUS current DESCRIPTION "Monitored channel center frequency. " ::= { monitoredChannelsEntry 2 } monitoredChannelsMonitoredOpticalPower OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "Monitored channel optical power. " ::= { monitoredChannelsEntry 3 } monitoredChannelsMonitoredWidth OBJECT-TYPE SYNTAX CoriantTypesFreqRoadm MAX-ACCESS read-only STATUS current DESCRIPTION "Monitored frequency width with unit MHz. default value :not-available" ::= { monitoredChannelsEntry 4 } qsfpSignalIntegrity OBJECT IDENTIFIER ::= { equipment 32 } qsfpSignalIntegrityTable OBJECT-TYPE SYNTAX SEQUENCE OF QsfpSignalIntegrityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Container for QSFP or QSFPxx signal integrity parameters defined in SFF-8636 ." ::= { qsfpSignalIntegrity 1 } qsfpSignalIntegrityEntry OBJECT-TYPE SYNTAX QsfpSignalIntegrityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of qsfpSignalIntegrityTable" INDEX { shelfId,slotId,subslotId,portId } ::= { qsfpSignalIntegrityTable 1 } QsfpSignalIntegrityEntry ::= SEQUENCE { qsfpSignalIntegrityTxInputEqFixedManualControlImpl QsfpSignalIntegritySignalVal, qsfpSignalIntegrityRxOutputEqPrecursorControlImpl QsfpSignalIntegritySignalVal, qsfpSignalIntegrityRxOutputEqPostcursorControlImpl QsfpSignalIntegritySignalVal, qsfpSignalIntegrityRxOutputAmplitudeControlImpl QsfpSignalIntegritySignalVal } qsfpSignalIntegrityTxInputEqFixedManualControlImpl OBJECT-TYPE SYNTAX QsfpSignalIntegritySignalVal MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates implementation status of Tx side input fixed manual equalization control. " ::= { qsfpSignalIntegrityEntry 1 } qsfpSignalIntegrityRxOutputEqPrecursorControlImpl OBJECT-TYPE SYNTAX QsfpSignalIntegritySignalVal MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates implementation status of Rx side output pre-cursor equalization control. " ::= { qsfpSignalIntegrityEntry 2 } qsfpSignalIntegrityRxOutputEqPostcursorControlImpl OBJECT-TYPE SYNTAX QsfpSignalIntegritySignalVal MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates implementation status of Rx side output post-cursor equalization control. " ::= { qsfpSignalIntegrityEntry 3 } qsfpSignalIntegrityRxOutputAmplitudeControlImpl OBJECT-TYPE SYNTAX QsfpSignalIntegritySignalVal MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates implementation status of Rx side output amplitude control. " ::= { qsfpSignalIntegrityEntry 4 } qsfpSignalIntegrityLane OBJECT IDENTIFIER ::= { equipment 33 } qsfpSignalIntegrityLaneTable OBJECT-TYPE SYNTAX SEQUENCE OF QsfpSignalIntegrityLaneEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of qspf lane signal integrity." ::= { qsfpSignalIntegrityLane 1 } qsfpSignalIntegrityLaneEntry OBJECT-TYPE SYNTAX QsfpSignalIntegrityLaneEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of qsfpSignalIntegrityLaneTable" INDEX { shelfId,slotId,subslotId,portId,qsfpSignalIntegrityLaneLaneId } ::= { qsfpSignalIntegrityLaneTable 1 } QsfpSignalIntegrityLaneEntry ::= SEQUENCE { qsfpSignalIntegrityLaneLaneId Unsigned32, qsfpSignalIntegrityLaneTxInputEqFixedManualControl QsfpSignalIntegrityControlVal, qsfpSignalIntegrityLaneTxInputEqAdaptiveControl QsfpSignalIntegritySignalVal, qsfpSignalIntegrityLaneRxOutputEqPrecursorControl QsfpSignalIntegrityControlVal, qsfpSignalIntegrityLaneRxOutputEqPostcursorControl QsfpSignalIntegrityControlVal, qsfpSignalIntegrityLaneRxOutputAmplitudeControl INTEGER } qsfpSignalIntegrityLaneLaneId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Id of pluggable lane. " ::= { qsfpSignalIntegrityLaneEntry 1 } qsfpSignalIntegrityLaneTxInputEqFixedManualControl OBJECT-TYPE SYNTAX QsfpSignalIntegrityControlVal MAX-ACCESS read-only STATUS current DESCRIPTION "Fixed manual equalization value of Tx side input for the lane. UNITS:dB default value :n/a" ::= { qsfpSignalIntegrityLaneEntry 2 } qsfpSignalIntegrityLaneTxInputEqAdaptiveControl OBJECT-TYPE SYNTAX QsfpSignalIntegritySignalVal MAX-ACCESS read-only STATUS current DESCRIPTION "Adaptive equalization control of Tx side input for Tx 1-4. " ::= { qsfpSignalIntegrityLaneEntry 3 } qsfpSignalIntegrityLaneRxOutputEqPrecursorControl OBJECT-TYPE SYNTAX QsfpSignalIntegrityControlVal MAX-ACCESS read-only STATUS current DESCRIPTION "Rx side output pre-cursor equalization values for Rx 1-4. UNITS:dB default value :n/a" ::= { qsfpSignalIntegrityLaneEntry 4 } qsfpSignalIntegrityLaneRxOutputEqPostcursorControl OBJECT-TYPE SYNTAX QsfpSignalIntegrityControlVal MAX-ACCESS read-only STATUS current DESCRIPTION "Rx side output post-cursor equalization values for Rx 1-4. UNITS:dB default value :n/a" ::= { qsfpSignalIntegrityLaneEntry 5 } qsfpSignalIntegrityLaneRxOutputAmplitudeControl OBJECT-TYPE SYNTAX INTEGER { nA (0), t100400mv (1), t300600mv (2), t400800mv (3), t6001200mv (4), notDefined (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Rx side output amplitude values for Rx 1-4. default value :n/a" ::= { qsfpSignalIntegrityLaneEntry 6 } opticalPowerLane OBJECT IDENTIFIER ::= { equipment 34 } opticalPowerLaneTable OBJECT-TYPE SYNTAX SEQUENCE OF OpticalPowerLaneEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { opticalPowerLane 1 } opticalPowerLaneEntry OBJECT-TYPE SYNTAX OpticalPowerLaneEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of opticalPowerLaneTable" INDEX { shelfId,slotId,subslotId,portId,opticalPowerLaneLaneId } ::= { opticalPowerLaneTable 1 } OpticalPowerLaneEntry ::= SEQUENCE { opticalPowerLaneLaneId Unsigned32, opticalPowerLaneRxOpticalPower CoriantTypesOpticalPower, opticalPowerLaneTxOpticalPower CoriantTypesOpticalPower } opticalPowerLaneLaneId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The physical lane index for optical pluggable " ::= { opticalPowerLaneEntry 1 } opticalPowerLaneRxOpticalPower OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "Received optical power " ::= { opticalPowerLaneEntry 2 } opticalPowerLaneTxOpticalPower OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "Transmitted optical power " ::= { opticalPowerLaneEntry 3 } cpuState OBJECT IDENTIFIER ::= { equipment 35 } cpuStateTable OBJECT-TYPE SYNTAX SEQUENCE OF CpuStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The module with CPU's utilization states" ::= { cpuState 1 } cpuStateEntry OBJECT-TYPE SYNTAX CpuStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of cpuStateTable" INDEX { shelfId,slotId } ::= { cpuStateTable 1 } CpuStateEntry ::= SEQUENCE { cpuStateCpuTotalUtilization CoriantTypesPercentagePrecision2 } cpuStateCpuTotalUtilization OBJECT-TYPE SYNTAX CoriantTypesPercentagePrecision2 MAX-ACCESS read-only STATUS current DESCRIPTION "The total CPUs' utilization " ::= { cpuStateEntry 1 } perCoreUtilization OBJECT IDENTIFIER ::= { equipment 36 } perCoreUtilizationTable OBJECT-TYPE SYNTAX SEQUENCE OF PerCoreUtilizationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each CPU core's utilization" ::= { perCoreUtilization 1 } perCoreUtilizationEntry OBJECT-TYPE SYNTAX PerCoreUtilizationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of perCoreUtilizationTable" INDEX { shelfId,slotId,perCoreUtilizationCoreIndex } ::= { perCoreUtilizationTable 1 } PerCoreUtilizationEntry ::= SEQUENCE { perCoreUtilizationCoreIndex Unsigned32, perCoreUtilizationUtilization CoriantTypesPercentagePrecision2 } perCoreUtilizationCoreIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CPU core " ::= { perCoreUtilizationEntry 1 } perCoreUtilizationUtilization OBJECT-TYPE SYNTAX CoriantTypesPercentagePrecision2 MAX-ACCESS read-only STATUS current DESCRIPTION "The utilization of current CPU core " ::= { perCoreUtilizationEntry 2 } memoryState OBJECT IDENTIFIER ::= { equipment 37 } memoryStateTable OBJECT-TYPE SYNTAX SEQUENCE OF MemoryStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "For module that have associated memory, these values report information about available and utilized memory" ::= { memoryState 1 } memoryStateEntry OBJECT-TYPE SYNTAX MemoryStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of memoryStateTable" INDEX { shelfId,slotId } ::= { memoryStateTable 1 } MemoryStateEntry ::= SEQUENCE { memoryStateAvailable OCTET STRING, memoryStateUtilized OCTET STRING } memoryStateAvailable OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The available memory physically installed, or logically allocated to the module. UNITS:bytes " ::= { memoryStateEntry 1 } memoryStateUtilized OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The memory currently in use by processes running on the module, not considering reserved memory that is not available for use. UNITS:bytes " ::= { memoryStateEntry 2 } channelStates OBJECT IDENTIFIER ::= { equipment 38 } channelStatesTable OBJECT-TYPE SYNTAX SEQUENCE OF ChannelStatesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { channelStates 1 } channelStatesEntry OBJECT-TYPE SYNTAX ChannelStatesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of channelStatesTable" INDEX { shelfId,slotId,subslotId,portId,channelStatesChannelId } ::= { channelStatesTable 1 } ChannelStatesEntry ::= SEQUENCE { channelStatesChannelId Unsigned32, channelStatesLaserBiasCurrent OCTET STRING } channelStatesChannelId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "multi channel pluggable's channel id " ::= { channelStatesEntry 1 } channelStatesLaserBiasCurrent OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION " The current applied by the system to the transmit laser to achieve the output power. The current is expressed in mA with up to two decimal precision. Just supply the instant value UNITS:mA " ::= { channelStatesEntry 2 } diagnosticAlarmThresholds OBJECT IDENTIFIER ::= { equipment 39 } diagnosticAlarmThresholdsTable OBJECT-TYPE SYNTAX SEQUENCE OF DiagnosticAlarmThresholdsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { diagnosticAlarmThresholds 1 } diagnosticAlarmThresholdsEntry OBJECT-TYPE SYNTAX DiagnosticAlarmThresholdsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of diagnosticAlarmThresholdsTable" INDEX { shelfId,slotId,subslotId,portId,diagnosticAlarmThresholdsDiagnosticParameter } ::= { diagnosticAlarmThresholdsTable 1 } DiagnosticAlarmThresholdsEntry ::= SEQUENCE { diagnosticAlarmThresholdsDiagnosticParameter INTEGER, diagnosticAlarmThresholdsParameterUnits INTEGER, diagnosticAlarmThresholdsHighThreshold OCTET STRING, diagnosticAlarmThresholdsLowThreshold OCTET STRING } diagnosticAlarmThresholdsDiagnosticParameter OBJECT-TYPE SYNTAX INTEGER { temperature (1), voltage (2), laserBias (3), laneRxPower (4), laneTxPower (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The diagnostic parameter for pluggable which support alarm by threshold " ::= { diagnosticAlarmThresholdsEntry 1 } diagnosticAlarmThresholdsParameterUnits OBJECT-TYPE SYNTAX INTEGER { celsius (1), v (2), ma (3), dbm (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { diagnosticAlarmThresholdsEntry 2 } diagnosticAlarmThresholdsHighThreshold OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The high alarm threshold of this parameter " ::= { diagnosticAlarmThresholdsEntry 3 } diagnosticAlarmThresholdsLowThreshold OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The low alarm threshold of this parameter " ::= { diagnosticAlarmThresholdsEntry 4 } supportedGainRange OBJECT IDENTIFIER ::= { equipment 40 } supportedGainRangeTable OBJECT-TYPE SYNTAX SEQUENCE OF SupportedGainRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { supportedGainRange 1 } supportedGainRangeEntry OBJECT-TYPE SYNTAX SupportedGainRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of supportedGainRangeTable" INDEX { shelfId,slotId,subslotId,amplifierName,supportedGainRangeRangeType } ::= { supportedGainRangeTable 1 } SupportedGainRangeEntry ::= SEQUENCE { supportedGainRangeRangeType AmplifierGainRangeType, supportedGainRangeGainRangeMin CoriantTypesDBPrecision1, supportedGainRangeGainRangeMax CoriantTypesDBPrecision1 } supportedGainRangeRangeType OBJECT-TYPE SYNTAX AmplifierGainRangeType MAX-ACCESS read-only STATUS current DESCRIPTION "The type of gain range for manually setting " ::= { supportedGainRangeEntry 1 } supportedGainRangeGainRangeMin OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum of settable gain for this range type " ::= { supportedGainRangeEntry 2 } supportedGainRangeGainRangeMax OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "The maxmum of settable gain for this range type " ::= { supportedGainRangeEntry 3 } channelDataList OBJECT IDENTIFIER ::= { equipment 41 } channelDataListTable OBJECT-TYPE SYNTAX SEQUENCE OF ChannelDataListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Per channel data for PCL restore." ::= { channelDataList 1 } channelDataListEntry OBJECT-TYPE SYNTAX ChannelDataListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of channelDataListTable" INDEX { shelfId,slotId,subslotId,amplifierName,channelDataListIndexId } ::= { channelDataListTable 1 } ChannelDataListEntry ::= SEQUENCE { channelDataListIndexId Unsigned32, channelDataListChannleId Unsigned32, channelDataListChannlePower INTEGER } channelDataListIndexId OBJECT-TYPE SYNTAX Unsigned32 (0..135) MAX-ACCESS read-only STATUS current DESCRIPTION "Integer ID of the channel-data. " ::= { channelDataListEntry 1 } channelDataListChannleId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "channle id. default value :0" ::= { channelDataListEntry 2 } channelDataListChannlePower OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "channle power. default value :0" ::= { channelDataListEntry 3 } tlmStatisticsdata OBJECT IDENTIFIER ::= { equipment 43 } tlmStatisticsdataTable OBJECT-TYPE SYNTAX SEQUENCE OF TlmStatisticsdataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { tlmStatisticsdata 1 } tlmStatisticsdataEntry OBJECT-TYPE SYNTAX TlmStatisticsdataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of tlmStatisticsdataTable" INDEX { shelfId } ::= { tlmStatisticsdataTable 1 } TlmStatisticsdataEntry ::= SEQUENCE { tlmStatisticsdataRefreshCounter Unsigned32, tlmStatisticsdataValidNum Unsigned32 } tlmStatisticsdataRefreshCounter OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "count refreshed times. default value :0" ::= { tlmStatisticsdataEntry 1 } tlmStatisticsdataValidNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of valid data list. default value :0" ::= { tlmStatisticsdataEntry 2 } tlmStatisticsdataList OBJECT IDENTIFIER ::= { equipment 44 } tlmStatisticsdataListTable OBJECT-TYPE SYNTAX SEQUENCE OF TlmStatisticsdataListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { tlmStatisticsdataList 1 } tlmStatisticsdataListEntry OBJECT-TYPE SYNTAX TlmStatisticsdataListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of tlmStatisticsdataListTable" INDEX { shelfId } ::= { tlmStatisticsdataListTable 1 } TlmStatisticsdataListEntry ::= SEQUENCE { tlmStatisticsdataListValidNum Unsigned32 } tlmStatisticsdataListValidNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of valid data list. default value :0" ::= { tlmStatisticsdataListEntry 1 } services OBJECT IDENTIFIER ::= { groove 4 } otn OBJECT IDENTIFIER ::= { services 1 } eth10g OBJECT IDENTIFIER ::= { otn 1 } eth10gTable OBJECT-TYPE SYNTAX SEQUENCE OF Eth10gEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Represents the 10GBE object. " ::= { eth10g 1 } eth10gEntry OBJECT-TYPE SYNTAX Eth10gEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of eth10gTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { eth10gTable 1 } Eth10gEntry ::= SEQUENCE { eth10gEthFecType CoriantTypesEthFec, eth10gEthFecTypeState CoriantTypesEthFec, eth10gTransmitInterpacketgap Unsigned32, eth10gGfpPayloadFcs CoriantTypesEnableSwitch, eth10gMappingMode INTEGER, eth10gAdminStatus INTEGER, eth10gOperStatus INTEGER, eth10gAvailStatus BITS, eth10gAliasName OCTET STRING, eth10gClientShutdown CoriantTypesYesNo, eth10gClientShutdownHoldoffTimer Unsigned32, eth10gNearEndAls CoriantTypesYesNo, eth10gAlsDegradeMode CoriantTypesEnableSwitch, eth10gLoopbackEnable CoriantTypesEnableSwitch, eth10gLoopbackType INTEGER, eth10gTestSignalType CoriantTypesTestSignalType, eth10gTestSignalEnable CoriantTypesTestSignalConfig, eth10gServiceLabel OCTET STRING, eth10gLldpStatusIf INTEGER, eth10gUpiValue INTEGER, eth10gHoldoffSignal CoriantTypesYesNo, eth10gManagedBy INTEGER } eth10gEthFecType OBJECT-TYPE SYNTAX CoriantTypesEthFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC working type of etyn port. default value :auto" ::= { eth10gEntry 1 } eth10gEthFecTypeState OBJECT-TYPE SYNTAX CoriantTypesEthFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC working state of etyn port. default value :disabled" ::= { eth10gEntry 2 } eth10gTransmitInterpacketgap OBJECT-TYPE SYNTAX Unsigned32 (8..12) MAX-ACCESS read-only STATUS current DESCRIPTION " Specifies the minimum transmit IPG value. default value :8" ::= { eth10gEntry 3 } eth10gGfpPayloadFcs OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION " Enabled: GFP payload FCS will be used, Ethernet frame FCS will be removed; Disabled: GFP payload FCS will not be inserted, Ethernet frame FCS will be used. default value :disabled" ::= { eth10gEntry 4 } eth10gMappingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), gmp (1), gfpF (2), t40gbmpOdu2e (3), preamble (4), bmpFixedstuff (5), bmp (6), amp (7), tttGmp (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The mapping mode of client port packets into ODUk. default value :not-applicable" ::= { eth10gEntry 5 } eth10gAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { eth10gEntry 6 } eth10gOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { eth10gEntry 7 } eth10gAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { eth10gEntry 8 } eth10gAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { eth10gEntry 9 } eth10gClientShutdown OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of client-shutdown. default value :no" ::= { eth10gEntry 10 } eth10gClientShutdownHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The hold off time of client shutdown or replacement siganl at egress direction. UNITS:milliseconds default value :0" ::= { eth10gEntry 11 } eth10gNearEndAls OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of near end ALS. default value :no" ::= { eth10gEntry 12 } eth10gAlsDegradeMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of defect BERSD-ODU trig ALS default value :disabled" ::= { eth10gEntry 13 } eth10gLoopbackEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of loopback function. default value :disabled" ::= { eth10gEntry 14 } eth10gLoopbackType OBJECT-TYPE SYNTAX INTEGER { none (0), terminal (1), facility (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of loopback function default value :none" ::= { eth10gEntry 15 } eth10gTestSignalType OBJECT-TYPE SYNTAX CoriantTypesTestSignalType MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of test signal. default value :NONE" ::= { eth10gEntry 16 } eth10gTestSignalEnable OBJECT-TYPE SYNTAX CoriantTypesTestSignalConfig MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of test signal function default value :NONE" ::= { eth10gEntry 17 } eth10gServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { eth10gEntry 18 } eth10gLldpStatusIf OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), rxonly (2), txandrx (3), disabled (4) } MAX-ACCESS read-only STATUS current DESCRIPTION " Port level lldp control. Value of 'rxonly', then the LLDP agent will receive lldp, when lldp-status-ne is also enabled. Value of 'disabled', then LLDP agent will not filter and receive LLDP frames on this port. If there is remote systems information which is received on this port and stored in the system before the lldp-status becomes disabled, then the information will naturally age out. Note: txOnly and txAndRx modes are not supported in Transponder module. default value :disabled" ::= { eth10gEntry 19 } eth10gUpiValue OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), g709 (1), gsupp43 (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The value of ODU2 upi in PREAMBLE mapping mode. default value :not-applicable" ::= { eth10gEntry 20 } eth10gHoldoffSignal OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Specify if specific signal will be sent out during hold off time which avoid downstream equipment consequent action in the duration. default value :no" ::= { eth10gEntry 21 } eth10gManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { eth10gEntry 22 } testSignalFacilityStatus OBJECT IDENTIFIER ::= { otn 2 } testSignalFacilityStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF TestSignalFacilityStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Test signal status for current facility." ::= { testSignalFacilityStatus 1 } testSignalFacilityStatusEntry OBJECT-TYPE SYNTAX TestSignalFacilityStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of testSignalFacilityStatusTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { testSignalFacilityStatusTable 1 } TestSignalFacilityStatusEntry ::= SEQUENCE { testSignalFacilityStatusPrbsSync INTEGER, testSignalFacilityStatusTestTimeDuration Unsigned32, testSignalFacilityStatusPrbsBitErrorCount IetfYangTypesGauge64 } testSignalFacilityStatusPrbsSync OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), inSync (1), outSync (2), errSync (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The test result of PRBS Synchronization default value :not-applicable" ::= { testSignalFacilityStatusEntry 1 } testSignalFacilityStatusTestTimeDuration OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time duration of signal test UNITS:seconds " ::= { testSignalFacilityStatusEntry 2 } testSignalFacilityStatusPrbsBitErrorCount OBJECT-TYPE SYNTAX IetfYangTypesGauge64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counting of bit error by PRBS Synchronization " ::= { testSignalFacilityStatusEntry 3 } lldpRemoteSystem OBJECT IDENTIFIER ::= { otn 3 } lldpRemoteSystemTable OBJECT-TYPE SYNTAX SEQUENCE OF LldpRemoteSystemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of LLDP neighbors." ::= { lldpRemoteSystem 1 } lldpRemoteSystemEntry OBJECT-TYPE SYNTAX LldpRemoteSystemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of lldpRemoteSystemTable" INDEX { shelfId,slotId,subslotId,portId,subportId,lldpRemoteSystemLldpRemoteIndex } ::= { lldpRemoteSystemTable 1 } LldpRemoteSystemEntry ::= SEQUENCE { lldpRemoteSystemLldpRemoteIndex Unsigned32, lldpRemoteSystemRemoteChassisIdSubtype INTEGER, lldpRemoteSystemRemoteChassisId OCTET STRING, lldpRemoteSystemRemotePortIdSubtype INTEGER, lldpRemoteSystemRemotePortId OCTET STRING, lldpRemoteSystemRemotePortDesc OCTET STRING, lldpRemoteSystemRemoteSysName OCTET STRING, lldpRemoteSystemRemoteSysDesc OCTET STRING, lldpRemoteSystemRemoteSysCapSupported LldpLldpSysCap, lldpRemoteSystemRemoteSysCapEnabled LldpLldpSysCap, lldpRemoteSystemManagementAddress OCTET STRING, lldpRemoteSystemManagementAddressType Unsigned32 } lldpRemoteSystemLldpRemoteIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION " This attribute represents an arbitrary local integer value used by this agent to identify a particular connection instance, unique only for the indicated remote system. " ::= { lldpRemoteSystemEntry 1 } lldpRemoteSystemRemoteChassisIdSubtype OBJECT-TYPE SYNTAX INTEGER { chassiscomponent (1), interfacealias (2), portcomponent (3), macaddress (4), networkaddress (5), interfacename (6), local (7) } MAX-ACCESS read-only STATUS current DESCRIPTION " This attribute describes the source of a chassis identifier. The enumeration 'chassisComponent(1)' represents a chassis identifier based on the value of entPhysicalAlias object (defined in IETF RFC 2737) for a chassis component (i.e., an entPhysicalClass value of 'chassis(3)'). The enumeration 'interfaceAlias(2)' represents a chassis identifier based on the value of ifAlias object (defined in IETF RFC 2863) for an interface on the containing chassis. The enumeration 'portComponent(3)' represents a chassis identifier based on the value of entPhysicalAlias object (defined in IETF RFC 2737) for a port or backplane component (i.e., entPhysicalClass value of 'port(10)' or 'backplane(4)'), within the containing chassis. The enumeration 'macAddress(4)' represents a chassis identifier based on the value of a unicast source address (encoded in network byte order and IEEE 802.3 canonical bit order), of a port on the containing chassis as defined in IEEE Std 802-2001. The enumeration 'networkAddress(5)' represents a chassis identifier based on a network address, associated with a particular chassis. The encoded address is actually composed of two fields. The first field is a single octet, representing the IANA AddressFamilyNumbers value for the specific address type, and the second field is the network address value. The enumeration 'interfaceName(6)' represents a chassis identifier based on the value of ifName object (defined in IETF RFC 2863) for an interface on the containing chassis. The enumeration 'local(7)' represents a chassis identifier based on a locally defined value. " ::= { lldpRemoteSystemEntry 2 } lldpRemoteSystemRemoteChassisId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION " This attribute describes the format of a chassis identifier string. Objects of this type are always used with an associated LldpChassisIdSubtype object, which identifies the format of the particular LldpChassisId object instance. If the associated LldpChassisIdSubtype object has a value of 'chassisComponent(1)', then the octet string identifies a particular instance of the entPhysicalAlias object (defined in IETF RFC 2737) for a chassis component (i.e., an entPhysicalClass value of 'chassis(3)'). If the associated LldpChassisIdSubtype object has a value of 'interfaceAlias(2)', then the octet string identifies a particular instance of the ifAlias object (defined in IETF RFC 2863) for an interface on the containing chassis. If the particular ifAlias object does not contain any values, another chassis identifier type should be used. If the associated LldpChassisIdSubtype object has a value of 'portComponent(3)', then the octet string identifies a particular instance of the entPhysicalAlias object (defined in IETF RFC 2737) for a port or backplane component within the containing chassis. If the associated LldpChassisIdSubtype object has a value of 'macAddress(4)', then this string identifies a particular unicast source address (encoded in network byte order and IEEE 802.3 canonical bit order), of a port on the containing chassis as defined in IEEE Std 802-2001. If the associated LldpChassisIdSubtype object has a value of 'networkAddress(5)', then this string identifies a particular network address, encoded in network byte order, associated with one or more ports on the containing chassis. The first octet contains the IANA Address Family Numbers enumeration value for the specific address type, and octets 2 through N contain the network address value in network byte order. If the associated LldpChassisIdSubtype object has a value of 'interfaceName(6)', then the octet string identifies a particular instance of the ifName object (defined in IETF RFC 2863) for an interface on the containing chassis. If the particular ifName object does not contain any values, another chassis identifier type should be used. If the associated LldpChassisIdSubtype object has a value of 'local(7)', then this string identifies a locally assigned Chassis ID. " ::= { lldpRemoteSystemEntry 3 } lldpRemoteSystemRemotePortIdSubtype OBJECT-TYPE SYNTAX INTEGER { interfacealias (1), portcomponent (2), macaddress (3), networkaddress (4), interfacename (5), agentcircuitid (6), local (7) } MAX-ACCESS read-only STATUS current DESCRIPTION " This attribute describes the format of a port identifier string. Objects of this type are always used with an associated LldpPortIdSubtype object, which identifies the format of the particular LldpPortId object instance. If the associated LldpPortIdSubtype object has a value of 'interfaceAlias(1)', then the octet string identifies a particular instance of the ifAlias object (defined in IETF RFC 2863). If the particular ifAlias object does not contain any values, another port identifier type should be used. If the associated LldpPortIdSubtype object has a value of 'portComponent(2)', then the octet string identifies a particular instance of the entPhysicalAlias object (defined in IETF RFC 2737) for a port or backplane component. If the associated LldpPortIdSubtype object has a value of 'macAddress(3)', then this string identifies a particular unicast source address (encoded in network byte order and IEEE 802.3 canonical bit order) associated with the port (IEEE Std 802-2001). If the associated LldpPortIdSubtype object has a value of 'networkAddress(4)', then this string identifies a network address associated with the port. The first octet contains the IANA AddressFamilyNumbers enumeration value for the specific address type, and octets 2 through N contain the networkAddress address value in network byte order. If the associated LldpPortIdSubtype object has a value of 'interfaceName(5)', then the octet string identifies a particular instance of the ifName object (defined in IETF RFC 2863). If the particular ifName object does not contain any values, another port identifier type should be used. If the associated LldpPortIdSubtype object has a value of 'agentCircuitId(6)', then this string identifies an agent-local identifier of the circuit (defined in RFC 3046). If the associated LldpPortIdSubtype object has a value of 'local(7)', then this string identifies a locally assigned port ID. " ::= { lldpRemoteSystemEntry 4 } lldpRemoteSystemRemotePortId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION " This attribute describes the format of a port identifier string. Objects of this type are always used with an associated LldpPortIdSubtype object, which identifies the format of the particular LldpPortId object instance. If the associated LldpPortIdSubtype object has a value of 'interfaceAlias(1)', then the octet string identifies a particular instance of the ifAlias object (defined in IETF RFC 2863). If the particular ifAlias object does not contain any values, another port identifier type should be used. If the associated LldpPortIdSubtype object has a value of 'portComponent(2)', then the octet string identifies a particular instance of the entPhysicalAlias object (defined in IETF RFC 2737) for a port or backplane component. If the associated LldpPortIdSubtype object has a value of 'macAddress(3)', then this string identifies a particular unicast source address (encoded in network byte order and IEEE 802.3 canonical bit order) associated with the port (IEEE Std 802-2001). If the associated LldpPortIdSubtype object has a value of 'networkAddress(4)', then this string identifies a network address associated with the port. The first octet contains the IANA AddressFamilyNumbers enumeration value for the specific address type, and octets 2 through N contain the networkAddress address value in network byte order. If the associated LldpPortIdSubtype object has a value of 'interfaceName(5)', then the octet string identifies a particular instance of the ifName object (defined in IETF RFC 2863). If the particular ifName object does not contain any values, another port identifier type should be used. If the associated LldpPortIdSubtype object has a value of 'agentCircuitId(6)', then this string identifies an agent-local identifier of the circuit (defined in RFC 3046). If the associated LldpPortIdSubtype object has a value of 'local(7)', then this string identifies a locally assigned port ID. " ::= { lldpRemoteSystemEntry 5 } lldpRemoteSystemRemotePortDesc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION " The string value used to identify the description of the given port associated with the remote system. " ::= { lldpRemoteSystemEntry 6 } lldpRemoteSystemRemoteSysName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION " The string value used to identify the system name of the remote system. sys-name: system name " ::= { lldpRemoteSystemEntry 7 } lldpRemoteSystemRemoteSysDesc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION " The string value used to identify the system description of the remote system. sys-desc: system description " ::= { lldpRemoteSystemEntry 8 } lldpRemoteSystemRemoteSysCapSupported OBJECT-TYPE SYNTAX LldpLldpSysCap MAX-ACCESS read-only STATUS current DESCRIPTION " This attribute describes the system capabilities. The bit 'other(0)' indicates that the system has capabilities other than those listed below. The bit 'repeater(1)' indicates that the system has repeater capability. The bit 'bridge(2)' indicates that the system has bridge capability. The bit 'wlanAccessPoint(3)' indicates that the system has WLAN access point capability. The bit 'router(4)' indicates that the system has router capability. The bit 'telephone(5)' indicates that the system has telephone capability. The bit 'docsisCableDevice(6)' indicates that the system has DOCSIS Cable Device capability (IETF RFC 2669 & 2670). The bit 'stationOnly(7)' indicates that the system has only station capability and nothing else. The bit 'cVLANComponent(8)' indicates that the system has C-VLAN component functionality. The bit 'sVLANComponent(9)' indicates that the system has S-VLAN component functionality. The bit 'twoPortMACRelay(10)' indicates that the system has Two-port MAC Relay (TPMR) functionality. sys-cap-supported: supported system capability " ::= { lldpRemoteSystemEntry 9 } lldpRemoteSystemRemoteSysCapEnabled OBJECT-TYPE SYNTAX LldpLldpSysCap MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute describes the system capabilities. The bit 'other(0)' indicates that the system has capabilities other than those listed below. The bit 'repeater(1)' indicates that the system has repeater capability. The bit 'bridge(2)' indicates that the system has bridge capability. The bit 'wlanAccessPoint(3)' indicates that the system has WLAN access point capability. The bit 'router(4)' indicates that the system has router capability. The bit 'telephone(5)' indicates that the system has telephone capability. The bit 'docsisCableDevice(6)' indicates that the system has DOCSIS Cable Device capability (IETF RFC 2669 & 2670). The bit 'stationOnly(7)' indicates that the system has only station capability and nothing else. The bit 'cVLANComponent(8)' indicates that the system has C-VLAN component functionality. The bit 'sVLANComponent(9)' indicates that the system has S-VLAN component functionality. The bit 'twoPortMACRelay(10)' indicates that the system has Two-port MAC Relay (TPMR) functionality. " ::= { lldpRemoteSystemEntry 10 } lldpRemoteSystemManagementAddress OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The last reported remote management address " ::= { lldpRemoteSystemEntry 11 } lldpRemoteSystemManagementAddressType OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The last reported remote management address type " ::= { lldpRemoteSystemEntry 12 } remoteManAddresses OBJECT IDENTIFIER ::= { otn 4 } remoteManAddressesTable OBJECT-TYPE SYNTAX SEQUENCE OF RemoteManAddressesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of management addresses of LLDP neighbor. man:managment, remote management addresses " ::= { remoteManAddresses 1 } remoteManAddressesEntry OBJECT-TYPE SYNTAX RemoteManAddressesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of remoteManAddressesTable" INDEX { shelfId,slotId,subslotId,portId,subportId,lldpRemoteSystemLldpRemoteIndex,remoteManAddressesRemoteManAddrSubtype,remoteManAddressesRemoteManAddr } ::= { remoteManAddressesTable 1 } RemoteManAddressesEntry ::= SEQUENCE { remoteManAddressesRemoteManAddrSubtype Unsigned32, remoteManAddressesRemoteManAddr OCTET STRING, remoteManAddressesRemoteManAddrIfSubtype Unsigned32, remoteManAddressesRemoteManAddrIfId Unsigned32, remoteManAddressesRemoteManAddrOid OCTET STRING } remoteManAddressesRemoteManAddrSubtype OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION " The type of management address identifier encoding used in the associated 'lldpLocManagmentAddr' object. " ::= { remoteManAddressesEntry 1 } remoteManAddressesRemoteManAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..62)) MAX-ACCESS read-only STATUS current DESCRIPTION " The string value used to identify the management address component associated with the remote system. The purpose of this address is to contact the management entity. man: management addr: address " ::= { remoteManAddressesEntry 2 } remoteManAddressesRemoteManAddrIfSubtype OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION " This attribute describes the basis of a particular type of interface associated with the management address. The enumeration 'unknown(1)' represents the case where the interface is not known. The enumeration 'ifIndex(2)' represents interface identifier based on the ifIndex MIB object. The enumeration 'systemPortNumber(3)' represents interface identifier based on the system port numbering convention. man: management addr: address " ::= { remoteManAddressesEntry 3 } remoteManAddressesRemoteManAddrIfId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION " The integer value used to identify the interface number regarding the management address component associated with the remote system. man: management addr: address " ::= { remoteManAddressesEntry 4 } remoteManAddressesRemoteManAddrOid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION " The OID value used to identify the type of hardware component or protocol entity associated with the management address advertised by the remote system agent. man: management addr: address oid: object identifier " ::= { remoteManAddressesEntry 5 } odu OBJECT IDENTIFIER ::= { otn 5 } oduTable OBJECT-TYPE SYNTAX SEQUENCE OF OduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { odu 1 } oduEntry OBJECT-TYPE SYNTAX OduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of oduTable" INDEX { shelfId,slotId,subslotId,portId,subportId,odutypeL1,oduidL1,odutypeL2,oduidL2,odutypeL3,oduidL3,odutypeL4,oduidL4 } ::= { oduTable 1 } OduEntry ::= SEQUENCE { odutypeL1 CoriantTypesOduType, oduidL1 Unsigned32, odutypeL2 CoriantTypesOduType, oduidL2 Unsigned32, odutypeL3 CoriantTypesOduType, oduidL3 Unsigned32, odutypeL4 CoriantTypesOduType, oduidL4 Unsigned32, oduAdminStatus INTEGER, oduOperStatus INTEGER, oduAvailStatus BITS, oduAliasName OCTET STRING, oduServiceLabel OCTET STRING, oduTribSlot CoriantTypesNumberList, oduRxPayloadType OCTET STRING, oduTxPayloadType OCTET STRING, oduNimEnable CoriantTypesEnableSwitch, oduDelayMeasurementEnable CoriantTypesEnableSwitch, oduOpuConfigActual INTEGER, oduClientSignalType INTEGER, oduExpSapi CoriantTypesTtiType15, oduExpDapi CoriantTypesTtiType15, oduExpOperator CoriantTypesTtiType32, oduTxSapi CoriantTypesTtiType15, oduTxDapi CoriantTypesTtiType15, oduTxOperator CoriantTypesTtiType32, oduTimDefectMode CoriantTypesTimMode, oduTimAct CoriantTypesEnableSwitch, oduRxSapi OCTET STRING, oduRxDapi OCTET STRING, oduRxOperator OCTET STRING, oduDegradeInterval Unsigned32, oduDegradeThreshold Unsigned32, oduTestSignalType CoriantTypesTestSignalType, oduTestSignalEnable CoriantTypesTestSignalConfig, oduTerminationMode INTEGER, oduType CoriantTypesOduType, oduManagedBy INTEGER, oduMsimConfig CoriantTypesEnableSwitch } odutypeL1 OBJECT-TYPE SYNTAX CoriantTypesOduType MAX-ACCESS read-only STATUS current DESCRIPTION "Level 1 ODU type " ::= { oduEntry 1 } oduidL1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of level 1 ODU " ::= { oduEntry 2 } odutypeL2 OBJECT-TYPE SYNTAX CoriantTypesOduType MAX-ACCESS read-only STATUS current DESCRIPTION "Level 2 ODU type " ::= { oduEntry 3 } oduidL2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of level 2 ODU " ::= { oduEntry 4 } odutypeL3 OBJECT-TYPE SYNTAX CoriantTypesOduType MAX-ACCESS read-only STATUS current DESCRIPTION "Level 3 ODU type " ::= { oduEntry 5 } oduidL3 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of level 3 ODU " ::= { oduEntry 6 } odutypeL4 OBJECT-TYPE SYNTAX CoriantTypesOduType MAX-ACCESS read-only STATUS current DESCRIPTION "Level 4 ODU type " ::= { oduEntry 7 } oduidL4 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of level 4 ODU " ::= { oduEntry 8 } oduAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { oduEntry 9 } oduOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { oduEntry 10 } oduAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { oduEntry 11 } oduAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { oduEntry 12 } oduServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { oduEntry 13 } oduTribSlot OBJECT-TYPE SYNTAX CoriantTypesNumberList MAX-ACCESS read-only STATUS current DESCRIPTION "Tributary slots of ODU, range 1 to 80 " ::= { oduEntry 14 } oduRxPayloadType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0|4)) MAX-ACCESS read-only STATUS current DESCRIPTION "Received payload-type of ODU " ::= { oduEntry 15 } oduTxPayloadType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0|4)) MAX-ACCESS read-only STATUS current DESCRIPTION "Transmitter payload-type of ODU " ::= { oduEntry 16 } oduNimEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of nim function default value :enabled" ::= { oduEntry 17 } oduDelayMeasurementEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of delay-measurement function default value :disabled" ::= { oduEntry 18 } oduOpuConfigActual OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), intact (1), client (2), mux (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The actual opu configuration type default value :not-applicable" ::= { oduEntry 19 } oduClientSignalType OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), fc8g (1), fc16g (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The ODUflex rate for special signal type default value :not-applicable" ::= { oduEntry 20 } oduExpSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected sapi(Source Access Point Identifier) " ::= { oduEntry 21 } oduExpDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected dapi(Destination Access Point Identifier) " ::= { oduEntry 22 } oduExpOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected operator TTI " ::= { oduEntry 23 } oduTxSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter sapi(Source Access Point Identifier) " ::= { oduEntry 24 } oduTxDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter dapi(Destination Access Point Identifier) " ::= { oduEntry 25 } oduTxOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter operator TTI " ::= { oduEntry 26 } oduTimDefectMode OBJECT-TYPE SYNTAX CoriantTypesTimMode MAX-ACCESS read-only STATUS current DESCRIPTION "The tim defect selection mode default value :NONE" ::= { oduEntry 27 } oduTimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { oduEntry 28 } oduRxSapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received sapi(Source Access Point Identifier) " ::= { oduEntry 29 } oduRxDapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received dapi(Destination Access Point Identifier) " ::= { oduEntry 30 } oduRxOperator OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received operator TTI " ::= { oduEntry 31 } oduDegradeInterval OBJECT-TYPE SYNTAX Unsigned32 (2..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The consecutive number of 1s intervals with the number of detected block errors exceeding the block error threshold for each of those seconds for the purposes of SDBER detection. default value :7" ::= { oduEntry 32 } oduDegradeThreshold OBJECT-TYPE SYNTAX Unsigned32 (1..2590845) MAX-ACCESS read-only STATUS current DESCRIPTION "The threshold number of block errors at which a 1s interval will be considered degraded for the purposes of SDBER detection. " ::= { oduEntry 33 } oduTestSignalType OBJECT-TYPE SYNTAX CoriantTypesTestSignalType MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of test signal. default value :NONE" ::= { oduEntry 34 } oduTestSignalEnable OBJECT-TYPE SYNTAX CoriantTypesTestSignalConfig MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of test signal function default value :NONE" ::= { oduEntry 35 } oduTerminationMode OBJECT-TYPE SYNTAX INTEGER { terminated (0), nonTerminated (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Termination mode for ODU. It works for trace label, nim , Delay Measurement and test signal function validation default value :terminated" ::= { oduEntry 36 } oduType OBJECT-TYPE SYNTAX CoriantTypesOduType MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the type of odu " ::= { oduEntry 37 } oduManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { oduEntry 38 } oduMsimConfig OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies msim alarm reporting or not when msi value received not followed G.709 definition Conditions:../odu-type = 'ODU4' default value :enabled" ::= { oduEntry 40 } oduEncryption OBJECT IDENTIFIER ::= { otn 6 } oduEncryptionTable OBJECT-TYPE SYNTAX SEQUENCE OF OduEncryptionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Encryption function for the ODU channel." ::= { oduEncryption 1 } oduEncryptionEntry OBJECT-TYPE SYNTAX OduEncryptionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of oduEncryptionTable" INDEX { shelfId,slotId,subslotId,portId,subportId,odutypeL1,oduidL1,odutypeL2,oduidL2,odutypeL3,oduidL3,odutypeL4,oduidL4 } ::= { oduEncryptionTable 1 } OduEncryptionEntry ::= SEQUENCE { oduEncryptionEncryptionEnable INTEGER, oduEncryptionBlockCipherMode INTEGER, oduEncryptionEncryptionInterval Unsigned32, oduEncryptionEncryptionTxStatus CoriantCommonOtnEncryStatusEnum, oduEncryptionEncryptionRxStatus CoriantCommonOtnEncryStatusEnum, oduEncryptionOduKeySyncSession CoriantCommonOtnKeySyncSession, oduEncryptionEncryptionTxChannelId OCTET STRING, oduEncryptionTimeToNextKey Unsigned32, oduEncryptionEncryptionTerminationDirection INTEGER } oduEncryptionEncryptionEnable OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2), enabledNonRevertive (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Setting AES-256 encryption on OTN default value :disabled" ::= { oduEncryptionEntry 1 } oduEncryptionBlockCipherMode OBJECT-TYPE SYNTAX INTEGER { ctr (1), gcm (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the block cipher mode of operation. " ::= { oduEncryptionEntry 2 } oduEncryptionEncryptionInterval OBJECT-TYPE SYNTAX Unsigned32 (10..1440) MAX-ACCESS read-only STATUS current DESCRIPTION "The encryption key rotation interval (in minutes) UNITS:minutes default value :30" ::= { oduEncryptionEntry 3 } oduEncryptionEncryptionTxStatus OBJECT-TYPE SYNTAX CoriantCommonOtnEncryStatusEnum MAX-ACCESS read-only STATUS current DESCRIPTION "The encryption status at transmit side of the ODU, which reflects the status of both encryption data and communication sessions. " ::= { oduEncryptionEntry 4 } oduEncryptionEncryptionRxStatus OBJECT-TYPE SYNTAX CoriantCommonOtnEncryStatusEnum MAX-ACCESS read-only STATUS current DESCRIPTION "The encryption status at receive side of the ODU, which reflects the status of both encryption data and communication sessions. " ::= { oduEncryptionEntry 5 } oduEncryptionOduKeySyncSession OBJECT-TYPE SYNTAX CoriantCommonOtnKeySyncSession MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate the associated session for the ODU channel to synchronize keys. default value :none" ::= { oduEncryptionEntry 6 } oduEncryptionEncryptionTxChannelId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Specify channel identifier of the encrypted ODU, which shall be unique within the NE. " ::= { oduEncryptionEntry 7 } oduEncryptionTimeToNextKey OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time left to rotate the ODU encryption key. UNITS:seconds default value :0" ::= { oduEncryptionEntry 8 } oduEncryptionEncryptionTerminationDirection OBJECT-TYPE SYNTAX INTEGER { physicalPort (1), crossConnection (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the encryption termination direction. default value :physical-port" ::= { oduEncryptionEntry 9 } testSignalStatus OBJECT IDENTIFIER ::= { otn 7 } testSignalStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF TestSignalStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Test signal status on ODU" ::= { testSignalStatus 1 } testSignalStatusEntry OBJECT-TYPE SYNTAX TestSignalStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of testSignalStatusTable" INDEX { shelfId,slotId,subslotId,portId,subportId,odutypeL1,oduidL1,odutypeL2,oduidL2,odutypeL3,oduidL3,odutypeL4,oduidL4 } ::= { testSignalStatusTable 1 } TestSignalStatusEntry ::= SEQUENCE { testSignalStatusPrbsSync INTEGER, testSignalStatusTestTimeDuration Unsigned32, testSignalStatusPrbsBitErrorCount IetfYangTypesGauge64 } testSignalStatusPrbsSync OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), inSync (1), outSync (2), errSync (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The test result of PRBS Synchronization default value :not-applicable" ::= { testSignalStatusEntry 1 } testSignalStatusTestTimeDuration OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time duration of signal test UNITS:seconds " ::= { testSignalStatusEntry 2 } testSignalStatusPrbsBitErrorCount OBJECT-TYPE SYNTAX IetfYangTypesGauge64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counting of bit error by PRBS Synchronization " ::= { testSignalStatusEntry 3 } eth40g OBJECT IDENTIFIER ::= { otn 8 } eth40gTable OBJECT-TYPE SYNTAX SEQUENCE OF Eth40gEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Represents the 40GBE object. " ::= { eth40g 1 } eth40gEntry OBJECT-TYPE SYNTAX Eth40gEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of eth40gTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { eth40gTable 1 } Eth40gEntry ::= SEQUENCE { eth40gEthFecType CoriantTypesEthFec, eth40gEthFecTypeState CoriantTypesEthFec, eth40gTransmitInterpacketgap Unsigned32, eth40gGfpPayloadFcs CoriantTypesEnableSwitch, eth40gMappingMode INTEGER, eth40gAdminStatus INTEGER, eth40gOperStatus INTEGER, eth40gAvailStatus BITS, eth40gAliasName OCTET STRING, eth40gClientShutdown CoriantTypesYesNo, eth40gClientShutdownHoldoffTimer Unsigned32, eth40gNearEndAls CoriantTypesYesNo, eth40gAlsDegradeMode CoriantTypesEnableSwitch, eth40gLoopbackEnable CoriantTypesEnableSwitch, eth40gLoopbackType INTEGER, eth40gTestSignalType CoriantTypesTestSignalType, eth40gTestSignalEnable CoriantTypesTestSignalConfig, eth40gServiceLabel OCTET STRING, eth40gLldpStatusIf INTEGER, eth40gHoldoffSignal CoriantTypesYesNo, eth40gManagedBy INTEGER } eth40gEthFecType OBJECT-TYPE SYNTAX CoriantTypesEthFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC working type of etyn port. default value :auto" ::= { eth40gEntry 1 } eth40gEthFecTypeState OBJECT-TYPE SYNTAX CoriantTypesEthFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC working state of etyn port. default value :disabled" ::= { eth40gEntry 2 } eth40gTransmitInterpacketgap OBJECT-TYPE SYNTAX Unsigned32 (8..12) MAX-ACCESS read-only STATUS current DESCRIPTION " Specifies the minimum transmit IPG value. default value :8" ::= { eth40gEntry 3 } eth40gGfpPayloadFcs OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION " Enabled: GFP payload FCS will be used, Ethernet frame FCS will be removed; Disabled: GFP payload FCS will not be inserted, Ethernet frame FCS will be used. default value :disabled" ::= { eth40gEntry 4 } eth40gMappingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), gmp (1), gfpF (2), t40gbmpOdu2e (3), preamble (4), bmpFixedstuff (5), bmp (6), amp (7), tttGmp (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The mapping mode of client port packets into ODUk. default value :not-applicable" ::= { eth40gEntry 5 } eth40gAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { eth40gEntry 6 } eth40gOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { eth40gEntry 7 } eth40gAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { eth40gEntry 8 } eth40gAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { eth40gEntry 9 } eth40gClientShutdown OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of client-shutdown. default value :no" ::= { eth40gEntry 10 } eth40gClientShutdownHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The hold off time of client shutdown or replacement siganl at egress direction. UNITS:milliseconds default value :0" ::= { eth40gEntry 11 } eth40gNearEndAls OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of near end ALS. default value :no" ::= { eth40gEntry 12 } eth40gAlsDegradeMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of defect BERSD-ODU trig ALS default value :disabled" ::= { eth40gEntry 13 } eth40gLoopbackEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of loopback function. default value :disabled" ::= { eth40gEntry 14 } eth40gLoopbackType OBJECT-TYPE SYNTAX INTEGER { none (0), terminal (1), facility (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of loopback function default value :none" ::= { eth40gEntry 15 } eth40gTestSignalType OBJECT-TYPE SYNTAX CoriantTypesTestSignalType MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of test signal. default value :NONE" ::= { eth40gEntry 16 } eth40gTestSignalEnable OBJECT-TYPE SYNTAX CoriantTypesTestSignalConfig MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of test signal function default value :NONE" ::= { eth40gEntry 17 } eth40gServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { eth40gEntry 18 } eth40gLldpStatusIf OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), rxonly (2), txandrx (3), disabled (4) } MAX-ACCESS read-only STATUS current DESCRIPTION " Port level lldp control. Value of 'rxonly', then the LLDP agent will receive lldp, when lldp-status-ne is also enabled. Value of 'disabled', then LLDP agent will not filter and receive LLDP frames on this port. If there is remote systems information which is received on this port and stored in the system before the lldp-status becomes disabled, then the information will naturally age out. Note: txOnly and txAndRx modes are not supported in Transponder module. default value :disabled" ::= { eth40gEntry 19 } eth40gHoldoffSignal OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Specify if specific signal will be sent out during hold off time which avoid downstream equipment consequent action in the duration. default value :no" ::= { eth40gEntry 20 } eth40gManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { eth40gEntry 21 } eth100g OBJECT IDENTIFIER ::= { otn 9 } eth100gTable OBJECT-TYPE SYNTAX SEQUENCE OF Eth100gEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the 100GBE object." ::= { eth100g 1 } eth100gEntry OBJECT-TYPE SYNTAX Eth100gEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of eth100gTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { eth100gTable 1 } Eth100gEntry ::= SEQUENCE { eth100gEthFecType CoriantTypesEthFec, eth100gEthFecTypeState CoriantTypesEthFec, eth100gTransmitInterpacketgap Unsigned32, eth100gGfpPayloadFcs CoriantTypesEnableSwitch, eth100gMappingMode INTEGER, eth100gAdminStatus INTEGER, eth100gOperStatus INTEGER, eth100gAvailStatus BITS, eth100gAliasName OCTET STRING, eth100gClientShutdown CoriantTypesYesNo, eth100gClientShutdownHoldoffTimer Unsigned32, eth100gNearEndAls CoriantTypesYesNo, eth100gAlsDegradeMode CoriantTypesEnableSwitch, eth100gLoopbackEnable CoriantTypesEnableSwitch, eth100gLoopbackType INTEGER, eth100gTestSignalType CoriantTypesTestSignalType, eth100gTestSignalEnable CoriantTypesTestSignalConfig, eth100gServiceLabel OCTET STRING, eth100gLldpStatusIf INTEGER, eth100gHoldoffSignal CoriantTypesYesNo, eth100gManagedBy INTEGER } eth100gEthFecType OBJECT-TYPE SYNTAX CoriantTypesEthFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC working type of etyn port. default value :auto" ::= { eth100gEntry 1 } eth100gEthFecTypeState OBJECT-TYPE SYNTAX CoriantTypesEthFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC working state of etyn port. default value :disabled" ::= { eth100gEntry 2 } eth100gTransmitInterpacketgap OBJECT-TYPE SYNTAX Unsigned32 (8..12) MAX-ACCESS read-only STATUS current DESCRIPTION " Specifies the minimum transmit IPG value. default value :8" ::= { eth100gEntry 3 } eth100gGfpPayloadFcs OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION " Enabled: GFP payload FCS will be used, Ethernet frame FCS will be removed; Disabled: GFP payload FCS will not be inserted, Ethernet frame FCS will be used. default value :disabled" ::= { eth100gEntry 4 } eth100gMappingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), gmp (1), gfpF (2), t40gbmpOdu2e (3), preamble (4), bmpFixedstuff (5), bmp (6), amp (7), tttGmp (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The mapping mode of client port packets into ODUk. default value :not-applicable" ::= { eth100gEntry 5 } eth100gAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { eth100gEntry 6 } eth100gOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { eth100gEntry 7 } eth100gAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { eth100gEntry 8 } eth100gAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { eth100gEntry 9 } eth100gClientShutdown OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of client-shutdown. default value :no" ::= { eth100gEntry 10 } eth100gClientShutdownHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The hold off time of client shutdown or replacement siganl at egress direction. UNITS:milliseconds default value :0" ::= { eth100gEntry 11 } eth100gNearEndAls OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of near end ALS. default value :no" ::= { eth100gEntry 12 } eth100gAlsDegradeMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of defect BERSD-ODU trig ALS default value :disabled" ::= { eth100gEntry 13 } eth100gLoopbackEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of loopback function. default value :disabled" ::= { eth100gEntry 14 } eth100gLoopbackType OBJECT-TYPE SYNTAX INTEGER { none (0), terminal (1), facility (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of loopback function default value :none" ::= { eth100gEntry 15 } eth100gTestSignalType OBJECT-TYPE SYNTAX CoriantTypesTestSignalType MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of test signal. default value :NONE" ::= { eth100gEntry 16 } eth100gTestSignalEnable OBJECT-TYPE SYNTAX CoriantTypesTestSignalConfig MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of test signal function default value :NONE" ::= { eth100gEntry 17 } eth100gServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { eth100gEntry 18 } eth100gLldpStatusIf OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), rxonly (2), txandrx (3), disabled (4) } MAX-ACCESS read-only STATUS current DESCRIPTION " Port level lldp control. Value of 'rxonly', then the LLDP agent will receive lldp, when lldp-status-ne is also enabled. Value of 'disabled', then LLDP agent will not filter and receive LLDP frames on this port. If there is remote systems information which is received on this port and stored in the system before the lldp-status becomes disabled, then the information will naturally age out. Note: txOnly and txAndRx modes are not supported in Transponder module. default value :disabled" ::= { eth100gEntry 19 } eth100gHoldoffSignal OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Specify if specific signal will be sent out during hold off time which avoid downstream equipment consequent action in the duration. default value :no" ::= { eth100gEntry 20 } eth100gManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { eth100gEntry 21 } otu4 OBJECT IDENTIFIER ::= { otn 10 } otu4Table OBJECT-TYPE SYNTAX SEQUENCE OF Otu4Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the otu4 object" ::= { otu4 1 } otu4Entry OBJECT-TYPE SYNTAX Otu4Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otu4Table" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { otu4Table 1 } Otu4Entry ::= SEQUENCE { otu4FecType CoriantTypesOtukFec, otu4AdminStatus INTEGER, otu4OperStatus INTEGER, otu4AvailStatus BITS, otu4AliasName OCTET STRING, otu4ServiceLabel OCTET STRING, otu4ExpSapi CoriantTypesTtiType15, otu4ExpDapi CoriantTypesTtiType15, otu4ExpOperator CoriantTypesTtiType32, otu4TxSapi CoriantTypesTtiType15, otu4TxDapi CoriantTypesTtiType15, otu4TxOperator CoriantTypesTtiType32, otu4TimDefectMode CoriantTypesTimMode, otu4TimAct CoriantTypesEnableSwitch, otu4RxSapi OCTET STRING, otu4RxDapi OCTET STRING, otu4RxOperator OCTET STRING, otu4DegradeInterval Unsigned32, otu4DegradeThreshold Unsigned32, otu4LoopbackEnable CoriantTypesEnableSwitch, otu4LoopbackType INTEGER, otu4ClientShutdown CoriantTypesYesNo, otu4ClientShutdownHoldoffTimer Unsigned32, otu4HoldoffSignal CoriantTypesYesNo, otu4NearEndAls CoriantTypesYesNo, otu4AlsDegradeMode CoriantTypesEnableSwitch, otu4ManagedBy INTEGER } otu4FecType OBJECT-TYPE SYNTAX CoriantTypesOtukFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC type of client OTUk. Conditions:(ancestor::port/port-type = 'client') or (ancestor::port/port-type = 'client-subport') default value :G709" ::= { otu4Entry 1 } otu4AdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { otu4Entry 2 } otu4OperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { otu4Entry 3 } otu4AvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { otu4Entry 4 } otu4AliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { otu4Entry 5 } otu4ServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { otu4Entry 6 } otu4ExpSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected sapi(Source Access Point Identifier) " ::= { otu4Entry 7 } otu4ExpDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected dapi(Destination Access Point Identifier) " ::= { otu4Entry 8 } otu4ExpOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected operator TTI " ::= { otu4Entry 9 } otu4TxSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter sapi(Source Access Point Identifier) " ::= { otu4Entry 10 } otu4TxDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter dapi(Destination Access Point Identifier) " ::= { otu4Entry 11 } otu4TxOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter operator TTI " ::= { otu4Entry 12 } otu4TimDefectMode OBJECT-TYPE SYNTAX CoriantTypesTimMode MAX-ACCESS read-only STATUS current DESCRIPTION "The tim defect selection mode default value :NONE" ::= { otu4Entry 13 } otu4TimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { otu4Entry 14 } otu4RxSapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received sapi(Source Access Point Identifier) " ::= { otu4Entry 15 } otu4RxDapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received dapi(Destination Access Point Identifier) " ::= { otu4Entry 16 } otu4RxOperator OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received operator TTI " ::= { otu4Entry 17 } otu4DegradeInterval OBJECT-TYPE SYNTAX Unsigned32 (2..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The consecutive number of 1s intervals with the number of detected block errors exceeding the block error threshold for each of those seconds for the purposes of SDBER detection. default value :7" ::= { otu4Entry 18 } otu4DegradeThreshold OBJECT-TYPE SYNTAX Unsigned32 (1..2590845) MAX-ACCESS read-only STATUS current DESCRIPTION "The threshold number of block errors at which a 1s interval will be considered degraded for the purposes of SDBER detection. default value :128459" ::= { otu4Entry 19 } otu4LoopbackEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of loopback function. default value :disabled" ::= { otu4Entry 20 } otu4LoopbackType OBJECT-TYPE SYNTAX INTEGER { none (0), terminal (1), facility (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of loopback function default value :none" ::= { otu4Entry 21 } otu4ClientShutdown OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of client-shutdown. default value :no" ::= { otu4Entry 22 } otu4ClientShutdownHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The hold off time of client shutdown or replacement siganl at egress direction. UNITS:milliseconds default value :0" ::= { otu4Entry 23 } otu4HoldoffSignal OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Specify if specific signal will be sent out during hold off time which avoid downstream equipment consequent action in the duration. default value :no" ::= { otu4Entry 24 } otu4NearEndAls OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of near end ALS. default value :no" ::= { otu4Entry 25 } otu4AlsDegradeMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of defect BERSD-ODU trig ALS default value :disabled" ::= { otu4Entry 26 } otu4ManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { otu4Entry 27 } otu2 OBJECT IDENTIFIER ::= { otn 11 } otu2Table OBJECT-TYPE SYNTAX SEQUENCE OF Otu2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the otu2 object" ::= { otu2 1 } otu2Entry OBJECT-TYPE SYNTAX Otu2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otu2Table" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { otu2Table 1 } Otu2Entry ::= SEQUENCE { otu2FecType CoriantTypesOtukFec, otu2AdminStatus INTEGER, otu2OperStatus INTEGER, otu2AvailStatus BITS, otu2AliasName OCTET STRING, otu2ServiceLabel OCTET STRING, otu2ExpSapi CoriantTypesTtiType15, otu2ExpDapi CoriantTypesTtiType15, otu2ExpOperator CoriantTypesTtiType32, otu2TxSapi CoriantTypesTtiType15, otu2TxDapi CoriantTypesTtiType15, otu2TxOperator CoriantTypesTtiType32, otu2TimDefectMode CoriantTypesTimMode, otu2TimAct CoriantTypesEnableSwitch, otu2RxSapi OCTET STRING, otu2RxDapi OCTET STRING, otu2RxOperator OCTET STRING, otu2DegradeInterval Unsigned32, otu2DegradeThreshold Unsigned32, otu2LoopbackEnable CoriantTypesEnableSwitch, otu2LoopbackType INTEGER, otu2ManagedBy INTEGER, otu2ClientShutdown CoriantTypesYesNo, otu2ClientShutdownHoldoffTimer Unsigned32, otu2HoldoffSignal CoriantTypesYesNo, otu2NearEndAls CoriantTypesYesNo, otu2AlsDegradeMode CoriantTypesEnableSwitch } otu2FecType OBJECT-TYPE SYNTAX CoriantTypesOtukFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC type of client OTUk. Conditions:(ancestor::port/port-type = 'client') or (ancestor::port/port-type = 'client-subport') default value :G709" ::= { otu2Entry 1 } otu2AdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { otu2Entry 2 } otu2OperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { otu2Entry 3 } otu2AvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { otu2Entry 4 } otu2AliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { otu2Entry 5 } otu2ServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { otu2Entry 6 } otu2ExpSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected sapi(Source Access Point Identifier) " ::= { otu2Entry 7 } otu2ExpDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected dapi(Destination Access Point Identifier) " ::= { otu2Entry 8 } otu2ExpOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected operator TTI " ::= { otu2Entry 9 } otu2TxSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter sapi(Source Access Point Identifier) " ::= { otu2Entry 10 } otu2TxDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter dapi(Destination Access Point Identifier) " ::= { otu2Entry 11 } otu2TxOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter operator TTI " ::= { otu2Entry 12 } otu2TimDefectMode OBJECT-TYPE SYNTAX CoriantTypesTimMode MAX-ACCESS read-only STATUS current DESCRIPTION "The tim defect selection mode default value :NONE" ::= { otu2Entry 13 } otu2TimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { otu2Entry 14 } otu2RxSapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received sapi(Source Access Point Identifier) " ::= { otu2Entry 15 } otu2RxDapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received dapi(Destination Access Point Identifier) " ::= { otu2Entry 16 } otu2RxOperator OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received operator TTI " ::= { otu2Entry 17 } otu2DegradeInterval OBJECT-TYPE SYNTAX Unsigned32 (2..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The consecutive number of 1s intervals with the number of detected block errors exceeding the block error threshold for each of those seconds for the purposes of SDBER detection. default value :7" ::= { otu2Entry 18 } otu2DegradeThreshold OBJECT-TYPE SYNTAX Unsigned32 (1..2590845) MAX-ACCESS read-only STATUS current DESCRIPTION "The threshold number of block errors at which a 1s interval will be considered degraded for the purposes of SDBER detection. default value :12304" ::= { otu2Entry 19 } otu2LoopbackEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of loopback function. default value :disabled" ::= { otu2Entry 20 } otu2LoopbackType OBJECT-TYPE SYNTAX INTEGER { none (0), terminal (1), facility (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of loopback function default value :none" ::= { otu2Entry 21 } otu2ManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { otu2Entry 22 } otu2ClientShutdown OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of client-shutdown. default value :no" ::= { otu2Entry 24 } otu2ClientShutdownHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The hold off time of client shutdown or replacement siganl at egress direction. UNITS:milliseconds default value :0" ::= { otu2Entry 25 } otu2HoldoffSignal OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Specify if specific signal will be sent out during hold off time which avoid downstream equipment consequent action in the duration. default value :no" ::= { otu2Entry 26 } otu2NearEndAls OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of near end ALS. default value :no" ::= { otu2Entry 27 } otu2AlsDegradeMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of defect BERSD-ODU trig ALS default value :disabled" ::= { otu2Entry 28 } otu2e OBJECT IDENTIFIER ::= { otn 12 } otu2eTable OBJECT-TYPE SYNTAX SEQUENCE OF Otu2eEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the otu2e object" ::= { otu2e 1 } otu2eEntry OBJECT-TYPE SYNTAX Otu2eEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otu2eTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { otu2eTable 1 } Otu2eEntry ::= SEQUENCE { otu2eFecType CoriantTypesOtukFec, otu2eAdminStatus INTEGER, otu2eOperStatus INTEGER, otu2eAvailStatus BITS, otu2eAliasName OCTET STRING, otu2eServiceLabel OCTET STRING, otu2eExpSapi CoriantTypesTtiType15, otu2eExpDapi CoriantTypesTtiType15, otu2eExpOperator CoriantTypesTtiType32, otu2eTxSapi CoriantTypesTtiType15, otu2eTxDapi CoriantTypesTtiType15, otu2eTxOperator CoriantTypesTtiType32, otu2eTimDefectMode CoriantTypesTimMode, otu2eTimAct CoriantTypesEnableSwitch, otu2eRxSapi OCTET STRING, otu2eRxDapi OCTET STRING, otu2eRxOperator OCTET STRING, otu2eDegradeInterval Unsigned32, otu2eDegradeThreshold Unsigned32, otu2eLoopbackEnable CoriantTypesEnableSwitch, otu2eLoopbackType INTEGER, otu2eManagedBy INTEGER, otu2eClientShutdown CoriantTypesYesNo, otu2eClientShutdownHoldoffTimer Unsigned32, otu2eHoldoffSignal CoriantTypesYesNo, otu2eNearEndAls CoriantTypesYesNo, otu2eAlsDegradeMode CoriantTypesEnableSwitch } otu2eFecType OBJECT-TYPE SYNTAX CoriantTypesOtukFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC type of client OTUk. Conditions:(ancestor::port/port-type = 'client') or (ancestor::port/port-type = 'client-subport') default value :G709" ::= { otu2eEntry 1 } otu2eAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { otu2eEntry 2 } otu2eOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { otu2eEntry 3 } otu2eAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { otu2eEntry 4 } otu2eAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { otu2eEntry 5 } otu2eServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { otu2eEntry 6 } otu2eExpSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected sapi(Source Access Point Identifier) " ::= { otu2eEntry 7 } otu2eExpDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected dapi(Destination Access Point Identifier) " ::= { otu2eEntry 8 } otu2eExpOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected operator TTI " ::= { otu2eEntry 9 } otu2eTxSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter sapi(Source Access Point Identifier) " ::= { otu2eEntry 10 } otu2eTxDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter dapi(Destination Access Point Identifier) " ::= { otu2eEntry 11 } otu2eTxOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter operator TTI " ::= { otu2eEntry 12 } otu2eTimDefectMode OBJECT-TYPE SYNTAX CoriantTypesTimMode MAX-ACCESS read-only STATUS current DESCRIPTION "The tim defect selection mode default value :NONE" ::= { otu2eEntry 13 } otu2eTimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { otu2eEntry 14 } otu2eRxSapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received sapi(Source Access Point Identifier) " ::= { otu2eEntry 15 } otu2eRxDapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received dapi(Destination Access Point Identifier) " ::= { otu2eEntry 16 } otu2eRxOperator OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received operator TTI " ::= { otu2eEntry 17 } otu2eDegradeInterval OBJECT-TYPE SYNTAX Unsigned32 (2..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The consecutive number of 1s intervals with the number of detected block errors exceeding the block error threshold for each of those seconds for the purposes of SDBER detection. default value :7" ::= { otu2eEntry 18 } otu2eDegradeThreshold OBJECT-TYPE SYNTAX Unsigned32 (1..2590845) MAX-ACCESS read-only STATUS current DESCRIPTION "The threshold number of block errors at which a 1s interval will be considered degraded for the purposes of SDBER detection. default value :12748" ::= { otu2eEntry 19 } otu2eLoopbackEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of loopback function. default value :disabled" ::= { otu2eEntry 20 } otu2eLoopbackType OBJECT-TYPE SYNTAX INTEGER { none (0), terminal (1), facility (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of loopback function default value :none" ::= { otu2eEntry 21 } otu2eManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { otu2eEntry 22 } otu2eClientShutdown OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of client-shutdown. default value :no" ::= { otu2eEntry 24 } otu2eClientShutdownHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The hold off time of client shutdown or replacement siganl at egress direction. UNITS:milliseconds default value :0" ::= { otu2eEntry 25 } otu2eHoldoffSignal OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Specify if specific signal will be sent out during hold off time which avoid downstream equipment consequent action in the duration. default value :no" ::= { otu2eEntry 26 } otu2eNearEndAls OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of near end ALS. default value :no" ::= { otu2eEntry 27 } otu2eAlsDegradeMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of defect BERSD-ODU trig ALS default value :disabled" ::= { otu2eEntry 28 } fc8g OBJECT IDENTIFIER ::= { otn 13 } fc8gTable OBJECT-TYPE SYNTAX SEQUENCE OF Fc8gEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Represents the FC8G object. " ::= { fc8g 1 } fc8gEntry OBJECT-TYPE SYNTAX Fc8gEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of fc8gTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { fc8gTable 1 } Fc8gEntry ::= SEQUENCE { fc8gMappingMode INTEGER, fc8gAdminStatus INTEGER, fc8gOperStatus INTEGER, fc8gAvailStatus BITS, fc8gAliasName OCTET STRING, fc8gClientShutdown CoriantTypesYesNo, fc8gClientShutdownHoldoffTimer Unsigned32, fc8gNearEndAls CoriantTypesYesNo, fc8gAlsDegradeMode CoriantTypesEnableSwitch, fc8gLoopbackEnable CoriantTypesEnableSwitch, fc8gLoopbackType INTEGER, fc8gTestSignalType CoriantTypesTestSignalType, fc8gTestSignalEnable CoriantTypesTestSignalConfig, fc8gServiceLabel OCTET STRING, fc8gHoldoffSignal CoriantTypesYesNo, fc8gManagedBy INTEGER } fc8gMappingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), gmp (1), gfpF (2), t40gbmpOdu2e (3), preamble (4), bmpFixedstuff (5), bmp (6), amp (7), tttGmp (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The mapping mode of client port packets into ODUk. default value :not-applicable" ::= { fc8gEntry 1 } fc8gAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { fc8gEntry 2 } fc8gOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { fc8gEntry 3 } fc8gAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { fc8gEntry 4 } fc8gAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { fc8gEntry 5 } fc8gClientShutdown OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of client-shutdown. default value :no" ::= { fc8gEntry 6 } fc8gClientShutdownHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The hold off time of client shutdown or replacement siganl at egress direction. UNITS:milliseconds default value :0" ::= { fc8gEntry 7 } fc8gNearEndAls OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of near end ALS. default value :no" ::= { fc8gEntry 8 } fc8gAlsDegradeMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of defect BERSD-ODU trig ALS default value :disabled" ::= { fc8gEntry 9 } fc8gLoopbackEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of loopback function. default value :disabled" ::= { fc8gEntry 10 } fc8gLoopbackType OBJECT-TYPE SYNTAX INTEGER { none (0), terminal (1), facility (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of loopback function default value :none" ::= { fc8gEntry 11 } fc8gTestSignalType OBJECT-TYPE SYNTAX CoriantTypesTestSignalType MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of test signal. default value :NONE" ::= { fc8gEntry 12 } fc8gTestSignalEnable OBJECT-TYPE SYNTAX CoriantTypesTestSignalConfig MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of test signal function default value :NONE" ::= { fc8gEntry 13 } fc8gServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { fc8gEntry 14 } fc8gHoldoffSignal OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Specify if specific signal will be sent out during hold off time which avoid downstream equipment consequent action in the duration. default value :no" ::= { fc8gEntry 15 } fc8gManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { fc8gEntry 16 } fc16g OBJECT IDENTIFIER ::= { otn 14 } fc16gTable OBJECT-TYPE SYNTAX SEQUENCE OF Fc16gEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Represents the FC16G object. " ::= { fc16g 1 } fc16gEntry OBJECT-TYPE SYNTAX Fc16gEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of fc16gTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { fc16gTable 1 } Fc16gEntry ::= SEQUENCE { fc16gMappingMode INTEGER, fc16gAdminStatus INTEGER, fc16gOperStatus INTEGER, fc16gAvailStatus BITS, fc16gAliasName OCTET STRING, fc16gClientShutdown CoriantTypesYesNo, fc16gClientShutdownHoldoffTimer Unsigned32, fc16gNearEndAls CoriantTypesYesNo, fc16gAlsDegradeMode CoriantTypesEnableSwitch, fc16gLoopbackEnable CoriantTypesEnableSwitch, fc16gLoopbackType INTEGER, fc16gTestSignalType CoriantTypesTestSignalType, fc16gTestSignalEnable CoriantTypesTestSignalConfig, fc16gServiceLabel OCTET STRING, fc16gHoldoffSignal CoriantTypesYesNo, fc16gManagedBy INTEGER } fc16gMappingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), gmp (1), gfpF (2), t40gbmpOdu2e (3), preamble (4), bmpFixedstuff (5), bmp (6), amp (7), tttGmp (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The mapping mode of client port packets into ODUk. default value :not-applicable" ::= { fc16gEntry 1 } fc16gAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { fc16gEntry 2 } fc16gOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { fc16gEntry 3 } fc16gAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { fc16gEntry 4 } fc16gAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { fc16gEntry 5 } fc16gClientShutdown OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of client-shutdown. default value :no" ::= { fc16gEntry 6 } fc16gClientShutdownHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The hold off time of client shutdown or replacement siganl at egress direction. UNITS:milliseconds default value :0" ::= { fc16gEntry 7 } fc16gNearEndAls OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of near end ALS. default value :no" ::= { fc16gEntry 8 } fc16gAlsDegradeMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of defect BERSD-ODU trig ALS default value :disabled" ::= { fc16gEntry 9 } fc16gLoopbackEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of loopback function. default value :disabled" ::= { fc16gEntry 10 } fc16gLoopbackType OBJECT-TYPE SYNTAX INTEGER { none (0), terminal (1), facility (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of loopback function default value :none" ::= { fc16gEntry 11 } fc16gTestSignalType OBJECT-TYPE SYNTAX CoriantTypesTestSignalType MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of test signal. default value :NONE" ::= { fc16gEntry 12 } fc16gTestSignalEnable OBJECT-TYPE SYNTAX CoriantTypesTestSignalConfig MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of test signal function default value :NONE" ::= { fc16gEntry 13 } fc16gServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { fc16gEntry 14 } fc16gHoldoffSignal OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Specify if specific signal will be sent out during hold off time which avoid downstream equipment consequent action in the duration. default value :no" ::= { fc16gEntry 15 } fc16gManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { fc16gEntry 16 } oc192 OBJECT IDENTIFIER ::= { otn 15 } oc192Table OBJECT-TYPE SYNTAX SEQUENCE OF Oc192Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Represents the OC192 object. " ::= { oc192 1 } oc192Entry OBJECT-TYPE SYNTAX Oc192Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of oc192Table" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { oc192Table 1 } Oc192Entry ::= SEQUENCE { oc192MappingMode INTEGER, oc192AdminStatus INTEGER, oc192OperStatus INTEGER, oc192AvailStatus BITS, oc192AliasName OCTET STRING, oc192ClientShutdown CoriantTypesYesNo, oc192ClientShutdownHoldoffTimer Unsigned32, oc192NearEndAls CoriantTypesYesNo, oc192AlsDegradeMode CoriantTypesEnableSwitch, oc192LoopbackEnable CoriantTypesEnableSwitch, oc192LoopbackType INTEGER, oc192TestSignalType CoriantTypesTestSignalType, oc192TestSignalEnable CoriantTypesTestSignalConfig, oc192ServiceLabel OCTET STRING, oc192ExpTrc CoriantTypesTtiType15, oc192TxTrc CoriantTypesTtiType15, oc192RxTrc OCTET STRING, oc192TimAct CoriantTypesEnableSwitch, oc192TimMonitor CoriantTypesEnableSwitch, oc192AisType INTEGER, oc192HoldoffSignal CoriantTypesYesNo, oc192ManagedBy INTEGER } oc192MappingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), gmp (1), gfpF (2), t40gbmpOdu2e (3), preamble (4), bmpFixedstuff (5), bmp (6), amp (7), tttGmp (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The mapping mode of client port packets into ODUk. default value :not-applicable" ::= { oc192Entry 1 } oc192AdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { oc192Entry 2 } oc192OperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { oc192Entry 3 } oc192AvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { oc192Entry 4 } oc192AliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { oc192Entry 5 } oc192ClientShutdown OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of client-shutdown. default value :no" ::= { oc192Entry 6 } oc192ClientShutdownHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The hold off time of client shutdown or replacement siganl at egress direction. UNITS:milliseconds default value :0" ::= { oc192Entry 7 } oc192NearEndAls OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of near end ALS. default value :no" ::= { oc192Entry 8 } oc192AlsDegradeMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of defect BERSD-ODU trig ALS default value :disabled" ::= { oc192Entry 9 } oc192LoopbackEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of loopback function. default value :disabled" ::= { oc192Entry 10 } oc192LoopbackType OBJECT-TYPE SYNTAX INTEGER { none (0), terminal (1), facility (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of loopback function default value :none" ::= { oc192Entry 11 } oc192TestSignalType OBJECT-TYPE SYNTAX CoriantTypesTestSignalType MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of test signal. default value :NONE" ::= { oc192Entry 12 } oc192TestSignalEnable OBJECT-TYPE SYNTAX CoriantTypesTestSignalConfig MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of test signal function default value :NONE" ::= { oc192Entry 13 } oc192ServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { oc192Entry 14 } oc192ExpTrc OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected trc(trail trace identification) " ::= { oc192Entry 15 } oc192TxTrc OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter trc(trail trace identification) Conditions:ancestor::card/switching-type = 'tdm' " ::= { oc192Entry 16 } oc192RxTrc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received trc(trail trace identification) " ::= { oc192Entry 17 } oc192TimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { oc192Entry 18 } oc192TimMonitor OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of tim defect monitor mode default value :disabled" ::= { oc192Entry 19 } oc192AisType OBJECT-TYPE SYNTAX INTEGER { genericAis (0), msAis (1), aisL (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL default value :Generic-AIS" ::= { oc192Entry 20 } oc192HoldoffSignal OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Specify if specific signal will be sent out during hold off time which avoid downstream equipment consequent action in the duration. default value :no" ::= { oc192Entry 21 } oc192ManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { oc192Entry 22 } stm64 OBJECT IDENTIFIER ::= { otn 16 } stm64Table OBJECT-TYPE SYNTAX SEQUENCE OF Stm64Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Represents the STM64 object. " ::= { stm64 1 } stm64Entry OBJECT-TYPE SYNTAX Stm64Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of stm64Table" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { stm64Table 1 } Stm64Entry ::= SEQUENCE { stm64MappingMode INTEGER, stm64AdminStatus INTEGER, stm64OperStatus INTEGER, stm64AvailStatus BITS, stm64AliasName OCTET STRING, stm64ClientShutdown CoriantTypesYesNo, stm64ClientShutdownHoldoffTimer Unsigned32, stm64NearEndAls CoriantTypesYesNo, stm64AlsDegradeMode CoriantTypesEnableSwitch, stm64LoopbackEnable CoriantTypesEnableSwitch, stm64LoopbackType INTEGER, stm64TestSignalType CoriantTypesTestSignalType, stm64TestSignalEnable CoriantTypesTestSignalConfig, stm64ServiceLabel OCTET STRING, stm64ExpTrc CoriantTypesTtiType15, stm64TxTrc CoriantTypesTtiType15, stm64RxTrc OCTET STRING, stm64TimAct CoriantTypesEnableSwitch, stm64TimMonitor CoriantTypesEnableSwitch, stm64AisType INTEGER, stm64HoldoffSignal CoriantTypesYesNo, stm64ManagedBy INTEGER } stm64MappingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), gmp (1), gfpF (2), t40gbmpOdu2e (3), preamble (4), bmpFixedstuff (5), bmp (6), amp (7), tttGmp (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The mapping mode of client port packets into ODUk. default value :not-applicable" ::= { stm64Entry 1 } stm64AdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { stm64Entry 2 } stm64OperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { stm64Entry 3 } stm64AvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { stm64Entry 4 } stm64AliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { stm64Entry 5 } stm64ClientShutdown OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of client-shutdown. default value :no" ::= { stm64Entry 6 } stm64ClientShutdownHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The hold off time of client shutdown or replacement siganl at egress direction. UNITS:milliseconds default value :0" ::= { stm64Entry 7 } stm64NearEndAls OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of near end ALS. default value :no" ::= { stm64Entry 8 } stm64AlsDegradeMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of defect BERSD-ODU trig ALS default value :disabled" ::= { stm64Entry 9 } stm64LoopbackEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of loopback function. default value :disabled" ::= { stm64Entry 10 } stm64LoopbackType OBJECT-TYPE SYNTAX INTEGER { none (0), terminal (1), facility (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of loopback function default value :none" ::= { stm64Entry 11 } stm64TestSignalType OBJECT-TYPE SYNTAX CoriantTypesTestSignalType MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of test signal. default value :NONE" ::= { stm64Entry 12 } stm64TestSignalEnable OBJECT-TYPE SYNTAX CoriantTypesTestSignalConfig MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of test signal function default value :NONE" ::= { stm64Entry 13 } stm64ServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { stm64Entry 14 } stm64ExpTrc OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected trc(trail trace identification) " ::= { stm64Entry 15 } stm64TxTrc OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter trc(trail trace identification) Conditions:ancestor::card/switching-type = 'tdm' " ::= { stm64Entry 16 } stm64RxTrc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received trc(trail trace identification) " ::= { stm64Entry 17 } stm64TimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { stm64Entry 18 } stm64TimMonitor OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of tim defect monitor mode default value :disabled" ::= { stm64Entry 19 } stm64AisType OBJECT-TYPE SYNTAX INTEGER { genericAis (0), msAis (1), aisL (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL default value :Generic-AIS" ::= { stm64Entry 20 } stm64HoldoffSignal OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Specify if specific signal will be sent out during hold off time which avoid downstream equipment consequent action in the duration. default value :no" ::= { stm64Entry 21 } stm64ManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { stm64Entry 22 } otuc2 OBJECT IDENTIFIER ::= { otn 17 } otuc2Table OBJECT-TYPE SYNTAX SEQUENCE OF Otuc2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the otuc2 object" ::= { otuc2 1 } otuc2Entry OBJECT-TYPE SYNTAX Otuc2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otuc2Table" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { otuc2Table 1 } Otuc2Entry ::= SEQUENCE { otuc2FecType CoriantTypesOtukFec, otuc2AdminStatus INTEGER, otuc2OperStatus INTEGER, otuc2AvailStatus BITS, otuc2AliasName OCTET STRING, otuc2ServiceLabel OCTET STRING, otuc2ExpSapi CoriantTypesTtiType15, otuc2ExpDapi CoriantTypesTtiType15, otuc2ExpOperator CoriantTypesTtiType32, otuc2TxSapi CoriantTypesTtiType15, otuc2TxDapi CoriantTypesTtiType15, otuc2TxOperator CoriantTypesTtiType32, otuc2TimDefectMode CoriantTypesTimMode, otuc2TimAct CoriantTypesEnableSwitch, otuc2RxSapi OCTET STRING, otuc2RxDapi OCTET STRING, otuc2RxOperator OCTET STRING, otuc2DegradeInterval Unsigned32, otuc2DegradeThreshold Unsigned32, otuc2ManagedBy INTEGER } otuc2FecType OBJECT-TYPE SYNTAX CoriantTypesOtukFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC type of client OTUk. Conditions:(ancestor::port/port-type = 'client') or (ancestor::port/port-type = 'client-subport') default value :G709" ::= { otuc2Entry 1 } otuc2AdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { otuc2Entry 2 } otuc2OperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { otuc2Entry 3 } otuc2AvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { otuc2Entry 4 } otuc2AliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { otuc2Entry 5 } otuc2ServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { otuc2Entry 6 } otuc2ExpSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected sapi(Source Access Point Identifier) " ::= { otuc2Entry 7 } otuc2ExpDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected dapi(Destination Access Point Identifier) " ::= { otuc2Entry 8 } otuc2ExpOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected operator TTI " ::= { otuc2Entry 9 } otuc2TxSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter sapi(Source Access Point Identifier) " ::= { otuc2Entry 10 } otuc2TxDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter dapi(Destination Access Point Identifier) " ::= { otuc2Entry 11 } otuc2TxOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter operator TTI " ::= { otuc2Entry 12 } otuc2TimDefectMode OBJECT-TYPE SYNTAX CoriantTypesTimMode MAX-ACCESS read-only STATUS current DESCRIPTION "The tim defect selection mode default value :NONE" ::= { otuc2Entry 13 } otuc2TimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { otuc2Entry 14 } otuc2RxSapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received sapi(Source Access Point Identifier) " ::= { otuc2Entry 15 } otuc2RxDapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received dapi(Destination Access Point Identifier) " ::= { otuc2Entry 16 } otuc2RxOperator OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received operator TTI " ::= { otuc2Entry 17 } otuc2DegradeInterval OBJECT-TYPE SYNTAX Unsigned32 (2..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The consecutive number of 1s intervals with the number of detected block errors exceeding the block error threshold for each of those seconds for the purposes of SDBER detection. default value :7" ::= { otuc2Entry 18 } otuc2DegradeThreshold OBJECT-TYPE SYNTAX Unsigned32 (1..2590845) MAX-ACCESS read-only STATUS current DESCRIPTION "The threshold number of block errors at which a 1s interval will be considered degraded for the purposes of SDBER detection. default value :259085" ::= { otuc2Entry 19 } otuc2ManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { otuc2Entry 20 } otuc3 OBJECT IDENTIFIER ::= { otn 18 } otuc3Table OBJECT-TYPE SYNTAX SEQUENCE OF Otuc3Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the otuc3 object" ::= { otuc3 1 } otuc3Entry OBJECT-TYPE SYNTAX Otuc3Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otuc3Table" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { otuc3Table 1 } Otuc3Entry ::= SEQUENCE { otuc3FecType CoriantTypesOtukFec, otuc3AdminStatus INTEGER, otuc3OperStatus INTEGER, otuc3AvailStatus BITS, otuc3AliasName OCTET STRING, otuc3ServiceLabel OCTET STRING, otuc3ExpSapi CoriantTypesTtiType15, otuc3ExpDapi CoriantTypesTtiType15, otuc3ExpOperator CoriantTypesTtiType32, otuc3TxSapi CoriantTypesTtiType15, otuc3TxDapi CoriantTypesTtiType15, otuc3TxOperator CoriantTypesTtiType32, otuc3TimDefectMode CoriantTypesTimMode, otuc3TimAct CoriantTypesEnableSwitch, otuc3RxSapi OCTET STRING, otuc3RxDapi OCTET STRING, otuc3RxOperator OCTET STRING, otuc3DegradeInterval Unsigned32, otuc3DegradeThreshold Unsigned32, otuc3ManagedBy INTEGER } otuc3FecType OBJECT-TYPE SYNTAX CoriantTypesOtukFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC type of client OTUk. Conditions:(ancestor::port/port-type = 'client') or (ancestor::port/port-type = 'client-subport') default value :G709" ::= { otuc3Entry 1 } otuc3AdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { otuc3Entry 2 } otuc3OperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { otuc3Entry 3 } otuc3AvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { otuc3Entry 4 } otuc3AliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { otuc3Entry 5 } otuc3ServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { otuc3Entry 6 } otuc3ExpSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected sapi(Source Access Point Identifier) " ::= { otuc3Entry 7 } otuc3ExpDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected dapi(Destination Access Point Identifier) " ::= { otuc3Entry 8 } otuc3ExpOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected operator TTI " ::= { otuc3Entry 9 } otuc3TxSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter sapi(Source Access Point Identifier) " ::= { otuc3Entry 10 } otuc3TxDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter dapi(Destination Access Point Identifier) " ::= { otuc3Entry 11 } otuc3TxOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter operator TTI " ::= { otuc3Entry 12 } otuc3TimDefectMode OBJECT-TYPE SYNTAX CoriantTypesTimMode MAX-ACCESS read-only STATUS current DESCRIPTION "The tim defect selection mode default value :NONE" ::= { otuc3Entry 13 } otuc3TimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { otuc3Entry 14 } otuc3RxSapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received sapi(Source Access Point Identifier) " ::= { otuc3Entry 15 } otuc3RxDapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received dapi(Destination Access Point Identifier) " ::= { otuc3Entry 16 } otuc3RxOperator OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received operator TTI " ::= { otuc3Entry 17 } otuc3DegradeInterval OBJECT-TYPE SYNTAX Unsigned32 (2..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The consecutive number of 1s intervals with the number of detected block errors exceeding the block error threshold for each of those seconds for the purposes of SDBER detection. default value :7" ::= { otuc3Entry 18 } otuc3DegradeThreshold OBJECT-TYPE SYNTAX Unsigned32 (1..2590845) MAX-ACCESS read-only STATUS current DESCRIPTION "The threshold number of block errors at which a 1s interval will be considered degraded for the purposes of SDBER detection. default value :388627" ::= { otuc3Entry 19 } otuc3ManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { otuc3Entry 20 } ochOs OBJECT IDENTIFIER ::= { otn 19 } ochOsTable OBJECT-TYPE SYNTAX SEQUENCE OF OchOsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the och-os MO" ::= { ochOs 1 } ochOsEntry OBJECT-TYPE SYNTAX OchOsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ochOsTable" INDEX { shelfId,slotId,subslotId,portId } ::= { ochOsTable 1 } OchOsEntry ::= SEQUENCE { ochOsModulationFormat INTEGER, ochOsLineEncoding INTEGER, ochOsFrequency CoriantTypesFreq, ochOsActualFrequency CoriantTypesFreqGeneric, ochOsRxFrequency CoriantTypesFreq, ochOsActualRxFrequency CoriantTypesFreqGeneric, ochOsLaserEnable CoriantTypesEnableSwitch, ochOsRequiredTxOpticalPower CoriantTypesOpticalPower, ochOsActualTxOpticalPower CoriantTypesOpticalPower, ochOsFecType CoriantTypesOtukFec, ochOsRxAttenuation CoriantTypesOpticalDB, ochOsTxFilterRollOff OCTET STRING, ochOsPreemphasis CoriantTypesEnableSwitch, ochOsPreemphasisValue OCTET STRING, ochOsAdminStatus INTEGER, ochOsOperStatus INTEGER, ochOsAvailStatus BITS, ochOsAliasName OCTET STRING, ochOsLoopbackEnable CoriantTypesEnableSwitch, ochOsLoopbackType INTEGER, ochOsServiceLabel OCTET STRING, ochOsDGD Unsigned32, ochOsCD INTEGER, ochOsOSNR CoriantTypesOpticalDB, ochOsQFactor CoriantTypesOpticalDB, ochOsPreFecBer OCTET STRING, ochOsCdRangeLow INTEGER, ochOsCdRangeHigh INTEGER, ochOsPropagateShutdown CoriantTypesYesNo, ochOsFastSopMode CoriantTypesEnableSwitch, ochOsRateClass INTEGER, ochOsManagedBy INTEGER, ochOsBICHM INTEGER, ochOsCdCompensationMode INTEGER, ochOsCdCompensationValue INTEGER, ochOsPropagateShutdownHoldoffTimer Unsigned32, ochOsSOPVector OCTET STRING } ochOsModulationFormat OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), dpQpsk (1), dp16qam (2), dp8qam (3), nrz (6), dp64qam (7), dpSp16qam (8), dpQpskSp16qam (9), dpSp16qam16qam (10), dp16qam32qam (11), dp32qam64qam (12), dp32qam (15), dpSpqpsk (17), dpSpqpskQpsk (18) } MAX-ACCESS read-only STATUS current DESCRIPTION " Currently och-os modulation format " ::= { ochOsEntry 1 } ochOsLineEncoding OBJECT-TYPE SYNTAX INTEGER { nonDifferential (1), differential (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " Currently line-encoding mode default value :non-differential" ::= { ochOsEntry 2 } ochOsFrequency OBJECT-TYPE SYNTAX CoriantTypesFreq MAX-ACCESS read-only STATUS current DESCRIPTION " The laser frequency. For tx-lo-independent laser-type, it set the tx laser frequency only. UNITS:MHz default value :0" ::= { ochOsEntry 3 } ochOsActualFrequency OBJECT-TYPE SYNTAX CoriantTypesFreqGeneric MAX-ACCESS read-only STATUS current DESCRIPTION " The actual laser frequency. If rx-frequency is 0, it reflects both Rx and Tx frequency for coherent interface. UNITS:MHz default value :0" ::= { ochOsEntry 4 } ochOsRxFrequency OBJECT-TYPE SYNTAX CoriantTypesFreq MAX-ACCESS read-only STATUS current DESCRIPTION " The rx laser frequency. Special for 0 means it is same as tx laser frequency. Conditions:../../possible-pluggable-types != 'SFP+' UNITS:MHz default value :0" ::= { ochOsEntry 5 } ochOsActualRxFrequency OBJECT-TYPE SYNTAX CoriantTypesFreqGeneric MAX-ACCESS read-only STATUS current DESCRIPTION " The actual rx laser frequency for coherent interface with separating Lo laser from Tx. 0 means Lo and Tx share the same laser where 'frequency' attriute will indicate both Tx and Rx. Conditions:../../possible-pluggable-types != 'SFP+' UNITS:MHz default value :0" ::= { ochOsEntry 6 } ochOsLaserEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION " The enable switching of output laser. default value :disabled" ::= { ochOsEntry 7 } ochOsRequiredTxOpticalPower OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION " This is to support adjustable optical power of Line side. default value :1.0" ::= { ochOsEntry 8 } ochOsActualTxOpticalPower OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION " This is the actual transmitting optical power of Line side. default value :-99.0" ::= { ochOsEntry 9 } ochOsFecType OBJECT-TYPE SYNTAX CoriantTypesOtukFec MAX-ACCESS read-only STATUS current DESCRIPTION "The FEC type of och-os default value :SDFEC25" ::= { ochOsEntry 10 } ochOsRxAttenuation OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION " This is to support configurable optical attenuation at receiver side which is based on the hardware capability on the port. default value :0.0" ::= { ochOsEntry 11 } ochOsTxFilterRollOff OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Transmitter filter roll off factor. default value :0.2" ::= { ochOsEntry 12 } ochOsPreemphasis OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Preemphasis of transmitted signal. default value :enabled" ::= { ochOsEntry 13 } ochOsPreemphasisValue OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Preemphasis of transmitted signal. default value :1.0" ::= { ochOsEntry 14 } ochOsAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { ochOsEntry 15 } ochOsOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { ochOsEntry 16 } ochOsAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { ochOsEntry 17 } ochOsAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { ochOsEntry 18 } ochOsLoopbackEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of loopback function. default value :disabled" ::= { ochOsEntry 19 } ochOsLoopbackType OBJECT-TYPE SYNTAX INTEGER { none (0), terminal (1), facility (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of loopback function default value :none" ::= { ochOsEntry 20 } ochOsServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { ochOsEntry 21 } ochOsDGD OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of Differential Group Delay UNITS:ps " ::= { ochOsEntry 22 } ochOsCD OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Value of Chromatic Dispersion UNITS:ps/nm " ::= { ochOsEntry 23 } ochOsOSNR OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION " Current value of OSNR. The result could be OSNR value with dB " ::= { ochOsEntry 24 } ochOsQFactor OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION " Current value of Q-factor " ::= { ochOsEntry 25 } ochOsPreFecBer OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Current value of PreFEC Bit Error Ratio. default value :-99.0" ::= { ochOsEntry 26 } ochOsCdRangeLow OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "low value of chromatic dispersion search range. UNITS:ps/nm default value :-45000" ::= { ochOsEntry 27 } ochOsCdRangeHigh OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "high value of chromatic dispersion search range. UNITS:ps/nm default value :45000" ::= { ochOsEntry 28 } ochOsPropagateShutdown OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "When the attribute value is set to yes, the transmit laser will be shutdown if the whole service of the direction has signal failure, the function mainly used in regeneration node to propagate signal failure as LOS. default value :no" ::= { ochOsEntry 29 } ochOsFastSopMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Specify if enable fast SOP (state of polarization) change tracking; if enabled, the interface will tolerate very fast SOP and transient. default value :disabled" ::= { ochOsEntry 31 } ochOsRateClass OBJECT-TYPE SYNTAX INTEGER { t10g (1), t11g (2), t100g (3), t150g (4), t200g (5), t300g (6), t400g (7), t500g (8), t600g (9), t250g (10), t350g (11), t450g (12), t550g (13) } MAX-ACCESS read-only STATUS current DESCRIPTION " Carried OTN signal basic rate class " ::= { ochOsEntry 32 } ochOsManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { ochOsEntry 33 } ochOsBICHM OBJECT-TYPE SYNTAX INTEGER (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "The BICHM (bit interleaved coded hybrid modulation) incremental step in 1/128 bits/symbol added to base modulation bits/symbol for the hybrid modes modulation-format. 0: Base modulation format bits/symbol; 1: 1/128 bits/symbol added to base modulation format bits/symbol; ... 127: 127/128 bits/symbol added to base modulation format bits/symbol default value :64" ::= { ochOsEntry 34 } ochOsCdCompensationMode OBJECT-TYPE SYNTAX INTEGER { auto (1), manual (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "chromatic dispersion compensation value source mode default value :auto" ::= { ochOsEntry 35 } ochOsCdCompensationValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "manual chromatic dispersion compensation value UNITS:ps/nm " ::= { ochOsEntry 36 } ochOsPropagateShutdownHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The hold off time of propagate shutdown. UNITS:milliseconds default value :0" ::= { ochOsEntry 37 } ochOsSOPVector OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..18)) MAX-ACCESS read-only STATUS current DESCRIPTION "The RX SOP (State Of Polarization) Stokes Vector S1 S2 S3 S1: the degree of linearly polarized light aligned to horizontal (X) axis S2: the degree of linearly polarized light aligned to +45 degree axis S3: the degree of righthand circularly polarized light " ::= { ochOsEntry 38 } wan10gSonet OBJECT IDENTIFIER ::= { otn 30 } wan10gSonetTable OBJECT-TYPE SYNTAX SEQUENCE OF Wan10gSonetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Represents the 10GWAN_SONET object. " ::= { wan10gSonet 1 } wan10gSonetEntry OBJECT-TYPE SYNTAX Wan10gSonetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of wan10gSonetTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { wan10gSonetTable 1 } Wan10gSonetEntry ::= SEQUENCE { wan10gSonetMappingMode INTEGER, wan10gSonetAdminStatus INTEGER, wan10gSonetOperStatus INTEGER, wan10gSonetAvailStatus BITS, wan10gSonetAliasName OCTET STRING, wan10gSonetClientShutdown CoriantTypesYesNo, wan10gSonetClientShutdownHoldoffTimer Unsigned32, wan10gSonetHoldoffSignal CoriantTypesYesNo, wan10gSonetNearEndAls CoriantTypesYesNo, wan10gSonetAlsDegradeMode CoriantTypesEnableSwitch, wan10gSonetLoopbackEnable CoriantTypesEnableSwitch, wan10gSonetLoopbackType INTEGER, wan10gSonetTestSignalType CoriantTypesTestSignalType, wan10gSonetTestSignalEnable CoriantTypesTestSignalConfig, wan10gSonetServiceLabel OCTET STRING, wan10gSonetExpTrc CoriantTypesTtiType15, wan10gSonetTxTrc CoriantTypesTtiType15, wan10gSonetRxTrc OCTET STRING, wan10gSonetTimAct CoriantTypesEnableSwitch, wan10gSonetTimMonitor CoriantTypesEnableSwitch, wan10gSonetAisType INTEGER, wan10gSonetManagedBy INTEGER } wan10gSonetMappingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), gmp (1), gfpF (2), t40gbmpOdu2e (3), preamble (4), bmpFixedstuff (5), bmp (6), amp (7), tttGmp (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The mapping mode of client port packets into ODUk. default value :not-applicable" ::= { wan10gSonetEntry 1 } wan10gSonetAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { wan10gSonetEntry 2 } wan10gSonetOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { wan10gSonetEntry 3 } wan10gSonetAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { wan10gSonetEntry 4 } wan10gSonetAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { wan10gSonetEntry 5 } wan10gSonetClientShutdown OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of client-shutdown. default value :no" ::= { wan10gSonetEntry 6 } wan10gSonetClientShutdownHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The hold off time of client shutdown or replacement siganl at egress direction. UNITS:milliseconds default value :0" ::= { wan10gSonetEntry 7 } wan10gSonetHoldoffSignal OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Specify if specific signal will be sent out during hold off time which avoid downstream equipment consequent action in the duration. default value :no" ::= { wan10gSonetEntry 8 } wan10gSonetNearEndAls OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of near end ALS. default value :no" ::= { wan10gSonetEntry 9 } wan10gSonetAlsDegradeMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of defect BERSD-ODU trig ALS default value :disabled" ::= { wan10gSonetEntry 10 } wan10gSonetLoopbackEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of loopback function. default value :disabled" ::= { wan10gSonetEntry 11 } wan10gSonetLoopbackType OBJECT-TYPE SYNTAX INTEGER { none (0), terminal (1), facility (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of loopback function default value :none" ::= { wan10gSonetEntry 12 } wan10gSonetTestSignalType OBJECT-TYPE SYNTAX CoriantTypesTestSignalType MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of test signal. default value :NONE" ::= { wan10gSonetEntry 13 } wan10gSonetTestSignalEnable OBJECT-TYPE SYNTAX CoriantTypesTestSignalConfig MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of test signal function default value :NONE" ::= { wan10gSonetEntry 14 } wan10gSonetServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { wan10gSonetEntry 15 } wan10gSonetExpTrc OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected trc(trail trace identification) " ::= { wan10gSonetEntry 16 } wan10gSonetTxTrc OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter trc(trail trace identification) Conditions:ancestor::card/switching-type = 'tdm' " ::= { wan10gSonetEntry 17 } wan10gSonetRxTrc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received trc(trail trace identification) " ::= { wan10gSonetEntry 18 } wan10gSonetTimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { wan10gSonetEntry 19 } wan10gSonetTimMonitor OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of tim defect monitor mode default value :disabled" ::= { wan10gSonetEntry 20 } wan10gSonetAisType OBJECT-TYPE SYNTAX INTEGER { genericAis (0), msAis (1), aisL (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL default value :Generic-AIS" ::= { wan10gSonetEntry 21 } wan10gSonetManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { wan10gSonetEntry 22 } wan10gSdh OBJECT IDENTIFIER ::= { otn 31 } wan10gSdhTable OBJECT-TYPE SYNTAX SEQUENCE OF Wan10gSdhEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Represents the 10GWAN_SDH object. " ::= { wan10gSdh 1 } wan10gSdhEntry OBJECT-TYPE SYNTAX Wan10gSdhEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of wan10gSdhTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { wan10gSdhTable 1 } Wan10gSdhEntry ::= SEQUENCE { wan10gSdhMappingMode INTEGER, wan10gSdhAdminStatus INTEGER, wan10gSdhOperStatus INTEGER, wan10gSdhAvailStatus BITS, wan10gSdhAliasName OCTET STRING, wan10gSdhClientShutdown CoriantTypesYesNo, wan10gSdhClientShutdownHoldoffTimer Unsigned32, wan10gSdhHoldoffSignal CoriantTypesYesNo, wan10gSdhNearEndAls CoriantTypesYesNo, wan10gSdhAlsDegradeMode CoriantTypesEnableSwitch, wan10gSdhLoopbackEnable CoriantTypesEnableSwitch, wan10gSdhLoopbackType INTEGER, wan10gSdhTestSignalType CoriantTypesTestSignalType, wan10gSdhTestSignalEnable CoriantTypesTestSignalConfig, wan10gSdhServiceLabel OCTET STRING, wan10gSdhExpTrc CoriantTypesTtiType15, wan10gSdhTxTrc CoriantTypesTtiType15, wan10gSdhRxTrc OCTET STRING, wan10gSdhTimAct CoriantTypesEnableSwitch, wan10gSdhTimMonitor CoriantTypesEnableSwitch, wan10gSdhAisType INTEGER, wan10gSdhManagedBy INTEGER } wan10gSdhMappingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), gmp (1), gfpF (2), t40gbmpOdu2e (3), preamble (4), bmpFixedstuff (5), bmp (6), amp (7), tttGmp (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The mapping mode of client port packets into ODUk. default value :not-applicable" ::= { wan10gSdhEntry 1 } wan10gSdhAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { wan10gSdhEntry 2 } wan10gSdhOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { wan10gSdhEntry 3 } wan10gSdhAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { wan10gSdhEntry 4 } wan10gSdhAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { wan10gSdhEntry 5 } wan10gSdhClientShutdown OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of client-shutdown. default value :no" ::= { wan10gSdhEntry 6 } wan10gSdhClientShutdownHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The hold off time of client shutdown or replacement siganl at egress direction. UNITS:milliseconds default value :0" ::= { wan10gSdhEntry 7 } wan10gSdhHoldoffSignal OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Specify if specific signal will be sent out during hold off time which avoid downstream equipment consequent action in the duration. default value :no" ::= { wan10gSdhEntry 8 } wan10gSdhNearEndAls OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of near end ALS. default value :no" ::= { wan10gSdhEntry 9 } wan10gSdhAlsDegradeMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of defect BERSD-ODU trig ALS default value :disabled" ::= { wan10gSdhEntry 10 } wan10gSdhLoopbackEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of loopback function. default value :disabled" ::= { wan10gSdhEntry 11 } wan10gSdhLoopbackType OBJECT-TYPE SYNTAX INTEGER { none (0), terminal (1), facility (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of loopback function default value :none" ::= { wan10gSdhEntry 12 } wan10gSdhTestSignalType OBJECT-TYPE SYNTAX CoriantTypesTestSignalType MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of test signal. default value :NONE" ::= { wan10gSdhEntry 13 } wan10gSdhTestSignalEnable OBJECT-TYPE SYNTAX CoriantTypesTestSignalConfig MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of test signal function default value :NONE" ::= { wan10gSdhEntry 14 } wan10gSdhServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { wan10gSdhEntry 15 } wan10gSdhExpTrc OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected trc(trail trace identification) " ::= { wan10gSdhEntry 16 } wan10gSdhTxTrc OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter trc(trail trace identification) Conditions:ancestor::card/switching-type = 'tdm' " ::= { wan10gSdhEntry 17 } wan10gSdhRxTrc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received trc(trail trace identification) " ::= { wan10gSdhEntry 18 } wan10gSdhTimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { wan10gSdhEntry 19 } wan10gSdhTimMonitor OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of tim defect monitor mode default value :disabled" ::= { wan10gSdhEntry 20 } wan10gSdhAisType OBJECT-TYPE SYNTAX INTEGER { genericAis (0), msAis (1), aisL (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL default value :Generic-AIS" ::= { wan10gSdhEntry 21 } wan10gSdhManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { wan10gSdhEntry 22 } eth10gStatistics OBJECT IDENTIFIER ::= { otn 32 } eth10gStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Eth10gStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { eth10gStatistics 1 } eth10gStatisticsEntry OBJECT-TYPE SYNTAX Eth10gStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of eth10gStatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { eth10gStatisticsTable 1 } Eth10gStatisticsEntry ::= SEQUENCE { eth10gStatisticsEntryLastClear IetfYangTypesDateAndTime, eth10gStatisticsEntryLossOfSignalSeconds OCTET STRING, eth10gStatisticsEntryBitErrorFec OCTET STRING, eth10gStatisticsEntryUncorrectedBlockErrorFec OCTET STRING, eth10gStatisticsEntryInSymbolErrors OCTET STRING, eth10gStatisticsEntryInDropEvents OCTET STRING, eth10gStatisticsEntryInOctets OCTET STRING, eth10gStatisticsEntryInPackets OCTET STRING, eth10gStatisticsEntryInBroadcastPackets OCTET STRING, eth10gStatisticsEntryInMulticastPackets OCTET STRING, eth10gStatisticsEntryInCrcAlignErrors OCTET STRING, eth10gStatisticsEntryInUndersizePackets OCTET STRING, eth10gStatisticsEntryInOversizePackets OCTET STRING, eth10gStatisticsEntryInFragments OCTET STRING, eth10gStatisticsEntryInJabbers OCTET STRING, eth10gStatisticsEntryInPackets64octets OCTET STRING, eth10gStatisticsEntryInPackets65to127octets OCTET STRING, eth10gStatisticsEntryInPackets128to255octets OCTET STRING, eth10gStatisticsEntryInPackets256to511octets OCTET STRING, eth10gStatisticsEntryInPackets512to1023octets OCTET STRING, eth10gStatisticsEntryInPackets1024to1518octets OCTET STRING, eth10gStatisticsEntryOutSymbolErrors OCTET STRING, eth10gStatisticsEntryOutDropEvents OCTET STRING, eth10gStatisticsEntryOutOctets OCTET STRING, eth10gStatisticsEntryOutPackets OCTET STRING, eth10gStatisticsEntryOutBroadcastPackets OCTET STRING, eth10gStatisticsEntryOutMulticastPackets OCTET STRING, eth10gStatisticsEntryOutCrcAlignErrors OCTET STRING, eth10gStatisticsEntryOutUndersizePackets OCTET STRING, eth10gStatisticsEntryOutOversizePackets OCTET STRING, eth10gStatisticsEntryOutFragments OCTET STRING, eth10gStatisticsEntryOutJabbers OCTET STRING, eth10gStatisticsEntryOutPackets64octets OCTET STRING, eth10gStatisticsEntryOutPackets65to127octets OCTET STRING, eth10gStatisticsEntryOutPackets128to255octets OCTET STRING, eth10gStatisticsEntryOutPackets256to511octets OCTET STRING, eth10gStatisticsEntryOutPackets512to1023octets OCTET STRING, eth10gStatisticsEntryOutPackets1024to1518octets OCTET STRING, eth10gStatisticsEntryInCodingViolation OCTET STRING, eth10gStatisticsEntryErroredSeconds OCTET STRING, eth10gStatisticsEntrySeverelyErroredSeconds OCTET STRING, eth10gStatisticsEntryUnavailableSeconds OCTET STRING } eth10gStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { eth10gStatisticsEntry 1 } eth10gStatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { eth10gStatisticsEntry 2 } eth10gStatisticsEntryBitErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for error bit forward error correction, corresponding to pm parameter BE-FEC UNITS:bits " ::= { eth10gStatisticsEntry 3 } eth10gStatisticsEntryUncorrectedBlockErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics blocks counting for uncorrected block error forward error correction, corresponding to pm parameter UBE-FEC UNITS:blocks " ::= { eth10gStatisticsEntry 4 } eth10gStatisticsEntryInSymbolErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics Times counting for input signal symbol errors, corresponding to pm parameter SE UNITS:Events " ::= { eth10gStatisticsEntry 5 } eth10gStatisticsEntryInDropEvents OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input signal drop events, corresponding to pm parameter DropEvents UNITS:events " ::= { eth10gStatisticsEntry 6 } eth10gStatisticsEntryInOctets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input signal octets, corresponding to pm parameter Octets UNITS:octets " ::= { eth10gStatisticsEntry 7 } eth10gStatisticsEntryInPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input signal packets, corresponding to pm parameter Pkts UNITS:packets " ::= { eth10gStatisticsEntry 8 } eth10gStatisticsEntryInBroadcastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input broadcast packets, corresponding to pm parameter BroadcastPkts UNITS:packets " ::= { eth10gStatisticsEntry 9 } eth10gStatisticsEntryInMulticastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input multicast packets, corresponding to pm parameter MulticastPkts UNITS:packets " ::= { eth10gStatisticsEntry 10 } eth10gStatisticsEntryInCrcAlignErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input CRC error packets, corresponding to pm parameter CRCAlignErrors UNITS:packets " ::= { eth10gStatisticsEntry 11 } eth10gStatisticsEntryInUndersizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input undersize packets, corresponding to pm parameter UndersizePkts UNITS:packets " ::= { eth10gStatisticsEntry 12 } eth10gStatisticsEntryInOversizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input oversize packets, corresponding to pm parameter OversizePkts UNITS:packets " ::= { eth10gStatisticsEntry 13 } eth10gStatisticsEntryInFragments OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input fragment packets, corresponding to pm parameter Fragments UNITS:packets " ::= { eth10gStatisticsEntry 14 } eth10gStatisticsEntryInJabbers OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input jabber packets, corresponding to pm parameter Jabbers UNITS:packets " ::= { eth10gStatisticsEntry 15 } eth10gStatisticsEntryInPackets64octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 64 octets packets, corresponding to pm parameter Pkts64Octets UNITS:packets " ::= { eth10gStatisticsEntry 16 } eth10gStatisticsEntryInPackets65to127octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 65 to 127 octets packets, corresponding to pm parameter Pkts65to127Octets UNITS:packets " ::= { eth10gStatisticsEntry 17 } eth10gStatisticsEntryInPackets128to255octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 128 to 255 octets packets, corresponding to pm parameter Pkts128to255Octets UNITS:packets " ::= { eth10gStatisticsEntry 18 } eth10gStatisticsEntryInPackets256to511octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 256 to 511 octets packets, corresponding to pm parameter Pkts256to511Octets UNITS:packets " ::= { eth10gStatisticsEntry 19 } eth10gStatisticsEntryInPackets512to1023octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 512 to 1023 octets packets, corresponding to pm parameter Pkts512to1023Octets UNITS:packets " ::= { eth10gStatisticsEntry 20 } eth10gStatisticsEntryInPackets1024to1518octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 1024 to 1518 octets packets, corresponding to pm parameter Pkts1024to1518Octets UNITS:packets " ::= { eth10gStatisticsEntry 21 } eth10gStatisticsEntryOutSymbolErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics Times counting for output signal symbol errors, corresponding to pm parameter SE UNITS:Events " ::= { eth10gStatisticsEntry 22 } eth10gStatisticsEntryOutDropEvents OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output signal drop events, corresponding to pm parameter DropEvents UNITS:events " ::= { eth10gStatisticsEntry 23 } eth10gStatisticsEntryOutOctets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output signal octets, corresponding to pm parameter Octets UNITS:octets " ::= { eth10gStatisticsEntry 24 } eth10gStatisticsEntryOutPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output signal packets, corresponding to pm parameter Pkts UNITS:packets " ::= { eth10gStatisticsEntry 25 } eth10gStatisticsEntryOutBroadcastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output broadcast packets, corresponding to pm parameter BroadcastPkts UNITS:packets " ::= { eth10gStatisticsEntry 26 } eth10gStatisticsEntryOutMulticastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output multicast packets, corresponding to pm parameter MulticastPkts UNITS:packets " ::= { eth10gStatisticsEntry 27 } eth10gStatisticsEntryOutCrcAlignErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output CRC error packets, corresponding to pm parameter CRCAlignErrors UNITS:packets " ::= { eth10gStatisticsEntry 28 } eth10gStatisticsEntryOutUndersizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output undersize packets, corresponding to pm parameter UndersizePkts UNITS:packets " ::= { eth10gStatisticsEntry 29 } eth10gStatisticsEntryOutOversizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output oversize packets, corresponding to pm parameter OversizePkts UNITS:packets " ::= { eth10gStatisticsEntry 30 } eth10gStatisticsEntryOutFragments OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output fragment packets, corresponding to pm parameter Fragments UNITS:packets " ::= { eth10gStatisticsEntry 31 } eth10gStatisticsEntryOutJabbers OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output jabber packets, corresponding to pm parameter Jabbers UNITS:packets " ::= { eth10gStatisticsEntry 32 } eth10gStatisticsEntryOutPackets64octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 64 octets packets, corresponding to pm parameter Pkts64Octets UNITS:packets " ::= { eth10gStatisticsEntry 33 } eth10gStatisticsEntryOutPackets65to127octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 65 to 127 octets packets, corresponding to pm parameter Pkts65to127Octets UNITS:packets " ::= { eth10gStatisticsEntry 34 } eth10gStatisticsEntryOutPackets128to255octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 128 to 255 octets packets, corresponding to pm parameter Pkts128to255Octets UNITS:packets " ::= { eth10gStatisticsEntry 35 } eth10gStatisticsEntryOutPackets256to511octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 256 to 511 octets packets, corresponding to pm parameter Pkts256to511Octets UNITS:packets " ::= { eth10gStatisticsEntry 36 } eth10gStatisticsEntryOutPackets512to1023octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 512 to 1023 octets packets, corresponding to pm parameter Pkts512to1023Octets UNITS:packets " ::= { eth10gStatisticsEntry 37 } eth10gStatisticsEntryOutPackets1024to1518octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 1024 to 1518 octets packets, corresponding to pm parameter Pkts1024to1518Octets UNITS:packets " ::= { eth10gStatisticsEntry 38 } eth10gStatisticsEntryInCodingViolation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for ingress coding violation, corresponding to pm parameter CV UNITS:bits " ::= { eth10gStatisticsEntry 39 } eth10gStatisticsEntryErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { eth10gStatisticsEntry 40 } eth10gStatisticsEntrySeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { eth10gStatisticsEntry 41 } eth10gStatisticsEntryUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { eth10gStatisticsEntry 42 } oduStatistics OBJECT IDENTIFIER ::= { otn 33 } oduStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF OduStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { oduStatistics 1 } oduStatisticsEntry OBJECT-TYPE SYNTAX OduStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of oduStatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId,odutypeL1,oduidL1,odutypeL2,oduidL2,odutypeL3,oduidL3,odutypeL4,oduidL4 } ::= { oduStatisticsTable 1 } OduStatisticsEntry ::= SEQUENCE { oduStatisticsEntryLastClear IetfYangTypesDateAndTime, oduStatisticsEntryErroredBlocks OCTET STRING, oduStatisticsEntryErroredSeconds OCTET STRING, oduStatisticsEntrySeverelyErroredSeconds OCTET STRING, oduStatisticsEntryUnavailableSeconds OCTET STRING, oduStatisticsEntryEncryptionFailRx OCTET STRING } oduStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { oduStatisticsEntry 1 } oduStatisticsEntryErroredBlocks OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for errored blocks, corresponding to pm parameter EB UNITS:blocks " ::= { oduStatisticsEntry 2 } oduStatisticsEntryErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { oduStatisticsEntry 3 } oduStatisticsEntrySeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { oduStatisticsEntry 4 } oduStatisticsEntryUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { oduStatisticsEntry 5 } oduStatisticsEntryEncryptionFailRx OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Failed Encryption Frames of Receive side, corresponding to pm parameter Encryption-fail-rx UNITS:frames " ::= { oduStatisticsEntry 6 } eth40gStatistics OBJECT IDENTIFIER ::= { otn 34 } eth40gStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Eth40gStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { eth40gStatistics 1 } eth40gStatisticsEntry OBJECT-TYPE SYNTAX Eth40gStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of eth40gStatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { eth40gStatisticsTable 1 } Eth40gStatisticsEntry ::= SEQUENCE { eth40gStatisticsEntryLastClear IetfYangTypesDateAndTime, eth40gStatisticsEntryLossOfSignalSeconds OCTET STRING, eth40gStatisticsEntryBitErrorFec OCTET STRING, eth40gStatisticsEntryUncorrectedBlockErrorFec OCTET STRING, eth40gStatisticsEntryInSymbolErrors OCTET STRING, eth40gStatisticsEntryInDropEvents OCTET STRING, eth40gStatisticsEntryInOctets OCTET STRING, eth40gStatisticsEntryInPackets OCTET STRING, eth40gStatisticsEntryInBroadcastPackets OCTET STRING, eth40gStatisticsEntryInMulticastPackets OCTET STRING, eth40gStatisticsEntryInCrcAlignErrors OCTET STRING, eth40gStatisticsEntryInUndersizePackets OCTET STRING, eth40gStatisticsEntryInOversizePackets OCTET STRING, eth40gStatisticsEntryInFragments OCTET STRING, eth40gStatisticsEntryInJabbers OCTET STRING, eth40gStatisticsEntryInPackets64octets OCTET STRING, eth40gStatisticsEntryInPackets65to127octets OCTET STRING, eth40gStatisticsEntryInPackets128to255octets OCTET STRING, eth40gStatisticsEntryInPackets256to511octets OCTET STRING, eth40gStatisticsEntryInPackets512to1023octets OCTET STRING, eth40gStatisticsEntryInPackets1024to1518octets OCTET STRING, eth40gStatisticsEntryOutSymbolErrors OCTET STRING, eth40gStatisticsEntryOutDropEvents OCTET STRING, eth40gStatisticsEntryOutOctets OCTET STRING, eth40gStatisticsEntryOutPackets OCTET STRING, eth40gStatisticsEntryOutBroadcastPackets OCTET STRING, eth40gStatisticsEntryOutMulticastPackets OCTET STRING, eth40gStatisticsEntryOutCrcAlignErrors OCTET STRING, eth40gStatisticsEntryOutUndersizePackets OCTET STRING, eth40gStatisticsEntryOutOversizePackets OCTET STRING, eth40gStatisticsEntryOutFragments OCTET STRING, eth40gStatisticsEntryOutJabbers OCTET STRING, eth40gStatisticsEntryOutPackets64octets OCTET STRING, eth40gStatisticsEntryOutPackets65to127octets OCTET STRING, eth40gStatisticsEntryOutPackets128to255octets OCTET STRING, eth40gStatisticsEntryOutPackets256to511octets OCTET STRING, eth40gStatisticsEntryOutPackets512to1023octets OCTET STRING, eth40gStatisticsEntryOutPackets1024to1518octets OCTET STRING, eth40gStatisticsEntryInCodingViolation OCTET STRING, eth40gStatisticsEntryErroredSeconds OCTET STRING, eth40gStatisticsEntrySeverelyErroredSeconds OCTET STRING, eth40gStatisticsEntryUnavailableSeconds OCTET STRING } eth40gStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { eth40gStatisticsEntry 1 } eth40gStatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { eth40gStatisticsEntry 2 } eth40gStatisticsEntryBitErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for error bit forward error correction, corresponding to pm parameter BE-FEC UNITS:bits " ::= { eth40gStatisticsEntry 3 } eth40gStatisticsEntryUncorrectedBlockErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics blocks counting for uncorrected block error forward error correction, corresponding to pm parameter UBE-FEC UNITS:blocks " ::= { eth40gStatisticsEntry 4 } eth40gStatisticsEntryInSymbolErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics Times counting for input signal symbol errors, corresponding to pm parameter SE UNITS:Events " ::= { eth40gStatisticsEntry 5 } eth40gStatisticsEntryInDropEvents OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input signal drop events, corresponding to pm parameter DropEvents UNITS:events " ::= { eth40gStatisticsEntry 6 } eth40gStatisticsEntryInOctets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input signal octets, corresponding to pm parameter Octets UNITS:octets " ::= { eth40gStatisticsEntry 7 } eth40gStatisticsEntryInPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input signal packets, corresponding to pm parameter Pkts UNITS:packets " ::= { eth40gStatisticsEntry 8 } eth40gStatisticsEntryInBroadcastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input broadcast packets, corresponding to pm parameter BroadcastPkts UNITS:packets " ::= { eth40gStatisticsEntry 9 } eth40gStatisticsEntryInMulticastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input multicast packets, corresponding to pm parameter MulticastPkts UNITS:packets " ::= { eth40gStatisticsEntry 10 } eth40gStatisticsEntryInCrcAlignErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input CRC error packets, corresponding to pm parameter CRCAlignErrors UNITS:packets " ::= { eth40gStatisticsEntry 11 } eth40gStatisticsEntryInUndersizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input undersize packets, corresponding to pm parameter UndersizePkts UNITS:packets " ::= { eth40gStatisticsEntry 12 } eth40gStatisticsEntryInOversizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input oversize packets, corresponding to pm parameter OversizePkts UNITS:packets " ::= { eth40gStatisticsEntry 13 } eth40gStatisticsEntryInFragments OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input fragment packets, corresponding to pm parameter Fragments UNITS:packets " ::= { eth40gStatisticsEntry 14 } eth40gStatisticsEntryInJabbers OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input jabber packets, corresponding to pm parameter Jabbers UNITS:packets " ::= { eth40gStatisticsEntry 15 } eth40gStatisticsEntryInPackets64octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 64 octets packets, corresponding to pm parameter Pkts64Octets UNITS:packets " ::= { eth40gStatisticsEntry 16 } eth40gStatisticsEntryInPackets65to127octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 65 to 127 octets packets, corresponding to pm parameter Pkts65to127Octets UNITS:packets " ::= { eth40gStatisticsEntry 17 } eth40gStatisticsEntryInPackets128to255octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 128 to 255 octets packets, corresponding to pm parameter Pkts128to255Octets UNITS:packets " ::= { eth40gStatisticsEntry 18 } eth40gStatisticsEntryInPackets256to511octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 256 to 511 octets packets, corresponding to pm parameter Pkts256to511Octets UNITS:packets " ::= { eth40gStatisticsEntry 19 } eth40gStatisticsEntryInPackets512to1023octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 512 to 1023 octets packets, corresponding to pm parameter Pkts512to1023Octets UNITS:packets " ::= { eth40gStatisticsEntry 20 } eth40gStatisticsEntryInPackets1024to1518octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 1024 to 1518 octets packets, corresponding to pm parameter Pkts1024to1518Octets UNITS:packets " ::= { eth40gStatisticsEntry 21 } eth40gStatisticsEntryOutSymbolErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics Times counting for output signal symbol errors, corresponding to pm parameter SE UNITS:Events " ::= { eth40gStatisticsEntry 22 } eth40gStatisticsEntryOutDropEvents OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output signal drop events, corresponding to pm parameter DropEvents UNITS:events " ::= { eth40gStatisticsEntry 23 } eth40gStatisticsEntryOutOctets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output signal octets, corresponding to pm parameter Octets UNITS:octets " ::= { eth40gStatisticsEntry 24 } eth40gStatisticsEntryOutPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output signal packets, corresponding to pm parameter Pkts UNITS:packets " ::= { eth40gStatisticsEntry 25 } eth40gStatisticsEntryOutBroadcastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output broadcast packets, corresponding to pm parameter BroadcastPkts UNITS:packets " ::= { eth40gStatisticsEntry 26 } eth40gStatisticsEntryOutMulticastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output multicast packets, corresponding to pm parameter MulticastPkts UNITS:packets " ::= { eth40gStatisticsEntry 27 } eth40gStatisticsEntryOutCrcAlignErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output CRC error packets, corresponding to pm parameter CRCAlignErrors UNITS:packets " ::= { eth40gStatisticsEntry 28 } eth40gStatisticsEntryOutUndersizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output undersize packets, corresponding to pm parameter UndersizePkts UNITS:packets " ::= { eth40gStatisticsEntry 29 } eth40gStatisticsEntryOutOversizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output oversize packets, corresponding to pm parameter OversizePkts UNITS:packets " ::= { eth40gStatisticsEntry 30 } eth40gStatisticsEntryOutFragments OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output fragment packets, corresponding to pm parameter Fragments UNITS:packets " ::= { eth40gStatisticsEntry 31 } eth40gStatisticsEntryOutJabbers OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output jabber packets, corresponding to pm parameter Jabbers UNITS:packets " ::= { eth40gStatisticsEntry 32 } eth40gStatisticsEntryOutPackets64octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 64 octets packets, corresponding to pm parameter Pkts64Octets UNITS:packets " ::= { eth40gStatisticsEntry 33 } eth40gStatisticsEntryOutPackets65to127octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 65 to 127 octets packets, corresponding to pm parameter Pkts65to127Octets UNITS:packets " ::= { eth40gStatisticsEntry 34 } eth40gStatisticsEntryOutPackets128to255octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 128 to 255 octets packets, corresponding to pm parameter Pkts128to255Octets UNITS:packets " ::= { eth40gStatisticsEntry 35 } eth40gStatisticsEntryOutPackets256to511octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 256 to 511 octets packets, corresponding to pm parameter Pkts256to511Octets UNITS:packets " ::= { eth40gStatisticsEntry 36 } eth40gStatisticsEntryOutPackets512to1023octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 512 to 1023 octets packets, corresponding to pm parameter Pkts512to1023Octets UNITS:packets " ::= { eth40gStatisticsEntry 37 } eth40gStatisticsEntryOutPackets1024to1518octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 1024 to 1518 octets packets, corresponding to pm parameter Pkts1024to1518Octets UNITS:packets " ::= { eth40gStatisticsEntry 38 } eth40gStatisticsEntryInCodingViolation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for ingress coding violation, corresponding to pm parameter CV UNITS:bits " ::= { eth40gStatisticsEntry 39 } eth40gStatisticsEntryErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { eth40gStatisticsEntry 40 } eth40gStatisticsEntrySeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { eth40gStatisticsEntry 41 } eth40gStatisticsEntryUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { eth40gStatisticsEntry 42 } eth100gStatistics OBJECT IDENTIFIER ::= { otn 35 } eth100gStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Eth100gStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { eth100gStatistics 1 } eth100gStatisticsEntry OBJECT-TYPE SYNTAX Eth100gStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of eth100gStatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { eth100gStatisticsTable 1 } Eth100gStatisticsEntry ::= SEQUENCE { eth100gStatisticsEntryLastClear IetfYangTypesDateAndTime, eth100gStatisticsEntryLossOfSignalSeconds OCTET STRING, eth100gStatisticsEntryBitErrorFec OCTET STRING, eth100gStatisticsEntryUncorrectedBlockErrorFec OCTET STRING, eth100gStatisticsEntryInSymbolErrors OCTET STRING, eth100gStatisticsEntryInDropEvents OCTET STRING, eth100gStatisticsEntryInOctets OCTET STRING, eth100gStatisticsEntryInPackets OCTET STRING, eth100gStatisticsEntryInBroadcastPackets OCTET STRING, eth100gStatisticsEntryInMulticastPackets OCTET STRING, eth100gStatisticsEntryInCrcAlignErrors OCTET STRING, eth100gStatisticsEntryInUndersizePackets OCTET STRING, eth100gStatisticsEntryInOversizePackets OCTET STRING, eth100gStatisticsEntryInFragments OCTET STRING, eth100gStatisticsEntryInJabbers OCTET STRING, eth100gStatisticsEntryInPackets64octets OCTET STRING, eth100gStatisticsEntryInPackets65to127octets OCTET STRING, eth100gStatisticsEntryInPackets128to255octets OCTET STRING, eth100gStatisticsEntryInPackets256to511octets OCTET STRING, eth100gStatisticsEntryInPackets512to1023octets OCTET STRING, eth100gStatisticsEntryInPackets1024to1518octets OCTET STRING, eth100gStatisticsEntryOutSymbolErrors OCTET STRING, eth100gStatisticsEntryOutDropEvents OCTET STRING, eth100gStatisticsEntryOutOctets OCTET STRING, eth100gStatisticsEntryOutPackets OCTET STRING, eth100gStatisticsEntryOutBroadcastPackets OCTET STRING, eth100gStatisticsEntryOutMulticastPackets OCTET STRING, eth100gStatisticsEntryOutCrcAlignErrors OCTET STRING, eth100gStatisticsEntryOutUndersizePackets OCTET STRING, eth100gStatisticsEntryOutOversizePackets OCTET STRING, eth100gStatisticsEntryOutFragments OCTET STRING, eth100gStatisticsEntryOutJabbers OCTET STRING, eth100gStatisticsEntryOutPackets64octets OCTET STRING, eth100gStatisticsEntryOutPackets65to127octets OCTET STRING, eth100gStatisticsEntryOutPackets128to255octets OCTET STRING, eth100gStatisticsEntryOutPackets256to511octets OCTET STRING, eth100gStatisticsEntryOutPackets512to1023octets OCTET STRING, eth100gStatisticsEntryOutPackets1024to1518octets OCTET STRING, eth100gStatisticsEntryInCodingViolation OCTET STRING, eth100gStatisticsEntryErroredSeconds OCTET STRING, eth100gStatisticsEntrySeverelyErroredSeconds OCTET STRING, eth100gStatisticsEntryUnavailableSeconds OCTET STRING } eth100gStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { eth100gStatisticsEntry 1 } eth100gStatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { eth100gStatisticsEntry 2 } eth100gStatisticsEntryBitErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for error bit forward error correction, corresponding to pm parameter BE-FEC UNITS:bits " ::= { eth100gStatisticsEntry 3 } eth100gStatisticsEntryUncorrectedBlockErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics blocks counting for uncorrected block error forward error correction, corresponding to pm parameter UBE-FEC UNITS:blocks " ::= { eth100gStatisticsEntry 4 } eth100gStatisticsEntryInSymbolErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics Times counting for input signal symbol errors, corresponding to pm parameter SE UNITS:Events " ::= { eth100gStatisticsEntry 5 } eth100gStatisticsEntryInDropEvents OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input signal drop events, corresponding to pm parameter DropEvents UNITS:events " ::= { eth100gStatisticsEntry 6 } eth100gStatisticsEntryInOctets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input signal octets, corresponding to pm parameter Octets UNITS:octets " ::= { eth100gStatisticsEntry 7 } eth100gStatisticsEntryInPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input signal packets, corresponding to pm parameter Pkts UNITS:packets " ::= { eth100gStatisticsEntry 8 } eth100gStatisticsEntryInBroadcastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input broadcast packets, corresponding to pm parameter BroadcastPkts UNITS:packets " ::= { eth100gStatisticsEntry 9 } eth100gStatisticsEntryInMulticastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input multicast packets, corresponding to pm parameter MulticastPkts UNITS:packets " ::= { eth100gStatisticsEntry 10 } eth100gStatisticsEntryInCrcAlignErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input CRC error packets, corresponding to pm parameter CRCAlignErrors UNITS:packets " ::= { eth100gStatisticsEntry 11 } eth100gStatisticsEntryInUndersizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input undersize packets, corresponding to pm parameter UndersizePkts UNITS:packets " ::= { eth100gStatisticsEntry 12 } eth100gStatisticsEntryInOversizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input oversize packets, corresponding to pm parameter OversizePkts UNITS:packets " ::= { eth100gStatisticsEntry 13 } eth100gStatisticsEntryInFragments OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input fragment packets, corresponding to pm parameter Fragments UNITS:packets " ::= { eth100gStatisticsEntry 14 } eth100gStatisticsEntryInJabbers OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input jabber packets, corresponding to pm parameter Jabbers UNITS:packets " ::= { eth100gStatisticsEntry 15 } eth100gStatisticsEntryInPackets64octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 64 octets packets, corresponding to pm parameter Pkts64Octets UNITS:packets " ::= { eth100gStatisticsEntry 16 } eth100gStatisticsEntryInPackets65to127octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 65 to 127 octets packets, corresponding to pm parameter Pkts65to127Octets UNITS:packets " ::= { eth100gStatisticsEntry 17 } eth100gStatisticsEntryInPackets128to255octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 128 to 255 octets packets, corresponding to pm parameter Pkts128to255Octets UNITS:packets " ::= { eth100gStatisticsEntry 18 } eth100gStatisticsEntryInPackets256to511octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 256 to 511 octets packets, corresponding to pm parameter Pkts256to511Octets UNITS:packets " ::= { eth100gStatisticsEntry 19 } eth100gStatisticsEntryInPackets512to1023octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 512 to 1023 octets packets, corresponding to pm parameter Pkts512to1023Octets UNITS:packets " ::= { eth100gStatisticsEntry 20 } eth100gStatisticsEntryInPackets1024to1518octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 1024 to 1518 octets packets, corresponding to pm parameter Pkts1024to1518Octets UNITS:packets " ::= { eth100gStatisticsEntry 21 } eth100gStatisticsEntryOutSymbolErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics Times counting for output signal symbol errors, corresponding to pm parameter SE UNITS:Events " ::= { eth100gStatisticsEntry 22 } eth100gStatisticsEntryOutDropEvents OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output signal drop events, corresponding to pm parameter DropEvents UNITS:events " ::= { eth100gStatisticsEntry 23 } eth100gStatisticsEntryOutOctets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output signal octets, corresponding to pm parameter Octets UNITS:octets " ::= { eth100gStatisticsEntry 24 } eth100gStatisticsEntryOutPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output signal packets, corresponding to pm parameter Pkts UNITS:packets " ::= { eth100gStatisticsEntry 25 } eth100gStatisticsEntryOutBroadcastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output broadcast packets, corresponding to pm parameter BroadcastPkts UNITS:packets " ::= { eth100gStatisticsEntry 26 } eth100gStatisticsEntryOutMulticastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output multicast packets, corresponding to pm parameter MulticastPkts UNITS:packets " ::= { eth100gStatisticsEntry 27 } eth100gStatisticsEntryOutCrcAlignErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output CRC error packets, corresponding to pm parameter CRCAlignErrors UNITS:packets " ::= { eth100gStatisticsEntry 28 } eth100gStatisticsEntryOutUndersizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output undersize packets, corresponding to pm parameter UndersizePkts UNITS:packets " ::= { eth100gStatisticsEntry 29 } eth100gStatisticsEntryOutOversizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output oversize packets, corresponding to pm parameter OversizePkts UNITS:packets " ::= { eth100gStatisticsEntry 30 } eth100gStatisticsEntryOutFragments OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output fragment packets, corresponding to pm parameter Fragments UNITS:packets " ::= { eth100gStatisticsEntry 31 } eth100gStatisticsEntryOutJabbers OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output jabber packets, corresponding to pm parameter Jabbers UNITS:packets " ::= { eth100gStatisticsEntry 32 } eth100gStatisticsEntryOutPackets64octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 64 octets packets, corresponding to pm parameter Pkts64Octets UNITS:packets " ::= { eth100gStatisticsEntry 33 } eth100gStatisticsEntryOutPackets65to127octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 65 to 127 octets packets, corresponding to pm parameter Pkts65to127Octets UNITS:packets " ::= { eth100gStatisticsEntry 34 } eth100gStatisticsEntryOutPackets128to255octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 128 to 255 octets packets, corresponding to pm parameter Pkts128to255Octets UNITS:packets " ::= { eth100gStatisticsEntry 35 } eth100gStatisticsEntryOutPackets256to511octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 256 to 511 octets packets, corresponding to pm parameter Pkts256to511Octets UNITS:packets " ::= { eth100gStatisticsEntry 36 } eth100gStatisticsEntryOutPackets512to1023octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 512 to 1023 octets packets, corresponding to pm parameter Pkts512to1023Octets UNITS:packets " ::= { eth100gStatisticsEntry 37 } eth100gStatisticsEntryOutPackets1024to1518octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 1024 to 1518 octets packets, corresponding to pm parameter Pkts1024to1518Octets UNITS:packets " ::= { eth100gStatisticsEntry 38 } eth100gStatisticsEntryInCodingViolation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for ingress coding violation, corresponding to pm parameter CV UNITS:bits " ::= { eth100gStatisticsEntry 39 } eth100gStatisticsEntryErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { eth100gStatisticsEntry 40 } eth100gStatisticsEntrySeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { eth100gStatisticsEntry 41 } eth100gStatisticsEntryUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { eth100gStatisticsEntry 42 } otu4Statistics OBJECT IDENTIFIER ::= { otn 36 } otu4StatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Otu4StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { otu4Statistics 1 } otu4StatisticsEntry OBJECT-TYPE SYNTAX Otu4StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otu4StatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { otu4StatisticsTable 1 } Otu4StatisticsEntry ::= SEQUENCE { otu4StatisticsEntryLastClear IetfYangTypesDateAndTime, otu4StatisticsEntryLossOfSignalSeconds OCTET STRING, otu4StatisticsEntryBitErrorFec OCTET STRING, otu4StatisticsEntryUncorrectedBlockErrorFec OCTET STRING, otu4StatisticsEntryErroredBlocks OCTET STRING, otu4StatisticsEntryErroredSeconds OCTET STRING, otu4StatisticsEntrySeverelyErroredSeconds OCTET STRING, otu4StatisticsEntryUnavailableSeconds OCTET STRING } otu4StatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { otu4StatisticsEntry 1 } otu4StatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { otu4StatisticsEntry 2 } otu4StatisticsEntryBitErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for error bit forward error correction, corresponding to pm parameter BE-FEC UNITS:bits " ::= { otu4StatisticsEntry 3 } otu4StatisticsEntryUncorrectedBlockErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics blocks counting for uncorrected block error forward error correction, corresponding to pm parameter UBE-FEC UNITS:blocks " ::= { otu4StatisticsEntry 4 } otu4StatisticsEntryErroredBlocks OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for errored blocks, corresponding to pm parameter EB UNITS:blocks " ::= { otu4StatisticsEntry 5 } otu4StatisticsEntryErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { otu4StatisticsEntry 6 } otu4StatisticsEntrySeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { otu4StatisticsEntry 7 } otu4StatisticsEntryUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { otu4StatisticsEntry 8 } otu2Statistics OBJECT IDENTIFIER ::= { otn 37 } otu2StatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Otu2StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { otu2Statistics 1 } otu2StatisticsEntry OBJECT-TYPE SYNTAX Otu2StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otu2StatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { otu2StatisticsTable 1 } Otu2StatisticsEntry ::= SEQUENCE { otu2StatisticsEntryLastClear IetfYangTypesDateAndTime, otu2StatisticsEntryLossOfSignalSeconds OCTET STRING, otu2StatisticsEntryBitErrorFec OCTET STRING, otu2StatisticsEntryUncorrectedBlockErrorFec OCTET STRING, otu2StatisticsEntryErroredBlocks OCTET STRING, otu2StatisticsEntryErroredSeconds OCTET STRING, otu2StatisticsEntrySeverelyErroredSeconds OCTET STRING, otu2StatisticsEntryUnavailableSeconds OCTET STRING } otu2StatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { otu2StatisticsEntry 1 } otu2StatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { otu2StatisticsEntry 2 } otu2StatisticsEntryBitErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for error bit forward error correction, corresponding to pm parameter BE-FEC UNITS:bits " ::= { otu2StatisticsEntry 3 } otu2StatisticsEntryUncorrectedBlockErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics blocks counting for uncorrected block error forward error correction, corresponding to pm parameter UBE-FEC UNITS:blocks " ::= { otu2StatisticsEntry 4 } otu2StatisticsEntryErroredBlocks OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for errored blocks, corresponding to pm parameter EB UNITS:blocks " ::= { otu2StatisticsEntry 5 } otu2StatisticsEntryErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { otu2StatisticsEntry 6 } otu2StatisticsEntrySeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { otu2StatisticsEntry 7 } otu2StatisticsEntryUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { otu2StatisticsEntry 8 } otu2eStatistics OBJECT IDENTIFIER ::= { otn 38 } otu2eStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Otu2eStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { otu2eStatistics 1 } otu2eStatisticsEntry OBJECT-TYPE SYNTAX Otu2eStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otu2eStatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { otu2eStatisticsTable 1 } Otu2eStatisticsEntry ::= SEQUENCE { otu2eStatisticsEntryLastClear IetfYangTypesDateAndTime, otu2eStatisticsEntryLossOfSignalSeconds OCTET STRING, otu2eStatisticsEntryBitErrorFec OCTET STRING, otu2eStatisticsEntryUncorrectedBlockErrorFec OCTET STRING, otu2eStatisticsEntryErroredBlocks OCTET STRING, otu2eStatisticsEntryErroredSeconds OCTET STRING, otu2eStatisticsEntrySeverelyErroredSeconds OCTET STRING, otu2eStatisticsEntryUnavailableSeconds OCTET STRING } otu2eStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { otu2eStatisticsEntry 1 } otu2eStatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { otu2eStatisticsEntry 2 } otu2eStatisticsEntryBitErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for error bit forward error correction, corresponding to pm parameter BE-FEC UNITS:bits " ::= { otu2eStatisticsEntry 3 } otu2eStatisticsEntryUncorrectedBlockErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics blocks counting for uncorrected block error forward error correction, corresponding to pm parameter UBE-FEC UNITS:blocks " ::= { otu2eStatisticsEntry 4 } otu2eStatisticsEntryErroredBlocks OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for errored blocks, corresponding to pm parameter EB UNITS:blocks " ::= { otu2eStatisticsEntry 5 } otu2eStatisticsEntryErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { otu2eStatisticsEntry 6 } otu2eStatisticsEntrySeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { otu2eStatisticsEntry 7 } otu2eStatisticsEntryUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { otu2eStatisticsEntry 8 } oc192Statistics OBJECT IDENTIFIER ::= { otn 39 } oc192StatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Oc192StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { oc192Statistics 1 } oc192StatisticsEntry OBJECT-TYPE SYNTAX Oc192StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of oc192StatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { oc192StatisticsTable 1 } Oc192StatisticsEntry ::= SEQUENCE { oc192StatisticsEntryLastClear IetfYangTypesDateAndTime, oc192StatisticsEntryLossOfSignalSeconds OCTET STRING, oc192StatisticsEntryInCodingViolation OCTET STRING, oc192StatisticsEntryInErroredSeconds OCTET STRING, oc192StatisticsEntryInSeverelyErroredSeconds OCTET STRING, oc192StatisticsEntryInUnavailableSeconds OCTET STRING, oc192StatisticsEntryInSeverelyErroredFrameSecond OCTET STRING } oc192StatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { oc192StatisticsEntry 1 } oc192StatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { oc192StatisticsEntry 2 } oc192StatisticsEntryInCodingViolation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for ingress coding violation, corresponding to pm parameter CV UNITS:bits " ::= { oc192StatisticsEntry 3 } oc192StatisticsEntryInErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { oc192StatisticsEntry 4 } oc192StatisticsEntryInSeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { oc192StatisticsEntry 5 } oc192StatisticsEntryInUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { oc192StatisticsEntry 6 } oc192StatisticsEntryInSeverelyErroredFrameSecond OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for ingress signal frame severely errored, corresponding to pm parameter SEFS UNITS:seconds " ::= { oc192StatisticsEntry 7 } stm64Statistics OBJECT IDENTIFIER ::= { otn 40 } stm64StatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Stm64StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { stm64Statistics 1 } stm64StatisticsEntry OBJECT-TYPE SYNTAX Stm64StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of stm64StatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { stm64StatisticsTable 1 } Stm64StatisticsEntry ::= SEQUENCE { stm64StatisticsEntryLastClear IetfYangTypesDateAndTime, stm64StatisticsEntryLossOfSignalSeconds OCTET STRING, stm64StatisticsEntryInBackgroundBlockError OCTET STRING, stm64StatisticsEntryInErroredSeconds OCTET STRING, stm64StatisticsEntryInSeverelyErroredSeconds OCTET STRING, stm64StatisticsEntryInUnavailableSeconds OCTET STRING, stm64StatisticsEntryInOutOfFrameSeconds OCTET STRING } stm64StatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { stm64StatisticsEntry 1 } stm64StatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { stm64StatisticsEntry 2 } stm64StatisticsEntryInBackgroundBlockError OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for ingress errored blocks, corresponding to pm parameter BBE UNITS:blocks " ::= { stm64StatisticsEntry 3 } stm64StatisticsEntryInErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { stm64StatisticsEntry 4 } stm64StatisticsEntryInSeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { stm64StatisticsEntry 5 } stm64StatisticsEntryInUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { stm64StatisticsEntry 6 } stm64StatisticsEntryInOutOfFrameSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for ingress signal lose of frame, corresponding to pm parameter OFS UNITS:seconds " ::= { stm64StatisticsEntry 7 } wan10gSonetStatistics OBJECT IDENTIFIER ::= { otn 41 } wan10gSonetStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Wan10gSonetStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { wan10gSonetStatistics 1 } wan10gSonetStatisticsEntry OBJECT-TYPE SYNTAX Wan10gSonetStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of wan10gSonetStatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { wan10gSonetStatisticsTable 1 } Wan10gSonetStatisticsEntry ::= SEQUENCE { wan10gSonetStatisticsEntryLastClear IetfYangTypesDateAndTime, wan10gSonetStatisticsEntryLossOfSignalSeconds OCTET STRING, wan10gSonetStatisticsEntryInCodingViolation OCTET STRING, wan10gSonetStatisticsEntryInErroredSeconds OCTET STRING, wan10gSonetStatisticsEntryInSeverelyErroredSeconds OCTET STRING, wan10gSonetStatisticsEntryInUnavailableSeconds OCTET STRING, wan10gSonetStatisticsEntryInSeverelyErroredFrameSecond OCTET STRING } wan10gSonetStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { wan10gSonetStatisticsEntry 1 } wan10gSonetStatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { wan10gSonetStatisticsEntry 2 } wan10gSonetStatisticsEntryInCodingViolation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for ingress coding violation, corresponding to pm parameter CV UNITS:bits " ::= { wan10gSonetStatisticsEntry 3 } wan10gSonetStatisticsEntryInErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { wan10gSonetStatisticsEntry 4 } wan10gSonetStatisticsEntryInSeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { wan10gSonetStatisticsEntry 5 } wan10gSonetStatisticsEntryInUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { wan10gSonetStatisticsEntry 6 } wan10gSonetStatisticsEntryInSeverelyErroredFrameSecond OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for ingress signal frame severely errored, corresponding to pm parameter SEFS UNITS:seconds " ::= { wan10gSonetStatisticsEntry 7 } wan10gSdhStatistics OBJECT IDENTIFIER ::= { otn 42 } wan10gSdhStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Wan10gSdhStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { wan10gSdhStatistics 1 } wan10gSdhStatisticsEntry OBJECT-TYPE SYNTAX Wan10gSdhStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of wan10gSdhStatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { wan10gSdhStatisticsTable 1 } Wan10gSdhStatisticsEntry ::= SEQUENCE { wan10gSdhStatisticsEntryLastClear IetfYangTypesDateAndTime, wan10gSdhStatisticsEntryLossOfSignalSeconds OCTET STRING, wan10gSdhStatisticsEntryInBackgroundBlockError OCTET STRING, wan10gSdhStatisticsEntryInErroredSeconds OCTET STRING, wan10gSdhStatisticsEntryInSeverelyErroredSeconds OCTET STRING, wan10gSdhStatisticsEntryInUnavailableSeconds OCTET STRING, wan10gSdhStatisticsEntryInOutOfFrameSeconds OCTET STRING } wan10gSdhStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { wan10gSdhStatisticsEntry 1 } wan10gSdhStatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { wan10gSdhStatisticsEntry 2 } wan10gSdhStatisticsEntryInBackgroundBlockError OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for ingress errored blocks, corresponding to pm parameter BBE UNITS:blocks " ::= { wan10gSdhStatisticsEntry 3 } wan10gSdhStatisticsEntryInErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { wan10gSdhStatisticsEntry 4 } wan10gSdhStatisticsEntryInSeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { wan10gSdhStatisticsEntry 5 } wan10gSdhStatisticsEntryInUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { wan10gSdhStatisticsEntry 6 } wan10gSdhStatisticsEntryInOutOfFrameSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for ingress signal lose of frame, corresponding to pm parameter OFS UNITS:seconds " ::= { wan10gSdhStatisticsEntry 7 } fc8gStatistics OBJECT IDENTIFIER ::= { otn 43 } fc8gStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Fc8gStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { fc8gStatistics 1 } fc8gStatisticsEntry OBJECT-TYPE SYNTAX Fc8gStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of fc8gStatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { fc8gStatisticsTable 1 } Fc8gStatisticsEntry ::= SEQUENCE { fc8gStatisticsEntryLastClear IetfYangTypesDateAndTime, fc8gStatisticsEntryLossOfSignalSeconds OCTET STRING, fc8gStatisticsEntryInSymbolErrors OCTET STRING } fc8gStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { fc8gStatisticsEntry 1 } fc8gStatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { fc8gStatisticsEntry 2 } fc8gStatisticsEntryInSymbolErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics Times counting for signal symbol errors, corresponding to pm parameter SE UNITS:Events " ::= { fc8gStatisticsEntry 3 } fc16gStatistics OBJECT IDENTIFIER ::= { otn 44 } fc16gStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Fc16gStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { fc16gStatistics 1 } fc16gStatisticsEntry OBJECT-TYPE SYNTAX Fc16gStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of fc16gStatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { fc16gStatisticsTable 1 } Fc16gStatisticsEntry ::= SEQUENCE { fc16gStatisticsEntryLastClear IetfYangTypesDateAndTime, fc16gStatisticsEntryLossOfSignalSeconds OCTET STRING, fc16gStatisticsEntryInSymbolErrors OCTET STRING } fc16gStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { fc16gStatisticsEntry 1 } fc16gStatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { fc16gStatisticsEntry 2 } fc16gStatisticsEntryInSymbolErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics Times counting for signal symbol errors, corresponding to pm parameter SE UNITS:Events " ::= { fc16gStatisticsEntry 3 } otuc2Statistics OBJECT IDENTIFIER ::= { otn 45 } otuc2StatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Otuc2StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { otuc2Statistics 1 } otuc2StatisticsEntry OBJECT-TYPE SYNTAX Otuc2StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otuc2StatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { otuc2StatisticsTable 1 } Otuc2StatisticsEntry ::= SEQUENCE { otuc2StatisticsEntryLastClear IetfYangTypesDateAndTime, otuc2StatisticsEntryLossOfSignalSeconds OCTET STRING, otuc2StatisticsEntryBitErrorFec OCTET STRING, otuc2StatisticsEntryUncorrectedBlockErrorFec OCTET STRING, otuc2StatisticsEntryErroredBlocks OCTET STRING, otuc2StatisticsEntryErroredSeconds OCTET STRING, otuc2StatisticsEntrySeverelyErroredSeconds OCTET STRING, otuc2StatisticsEntryUnavailableSeconds OCTET STRING } otuc2StatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { otuc2StatisticsEntry 1 } otuc2StatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { otuc2StatisticsEntry 2 } otuc2StatisticsEntryBitErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for error bit forward error correction, corresponding to pm parameter BE-FEC UNITS:bits " ::= { otuc2StatisticsEntry 3 } otuc2StatisticsEntryUncorrectedBlockErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics blocks counting for uncorrected block error forward error correction, corresponding to pm parameter UBE-FEC UNITS:blocks " ::= { otuc2StatisticsEntry 4 } otuc2StatisticsEntryErroredBlocks OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for errored blocks, corresponding to pm parameter EB UNITS:blocks " ::= { otuc2StatisticsEntry 5 } otuc2StatisticsEntryErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { otuc2StatisticsEntry 6 } otuc2StatisticsEntrySeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { otuc2StatisticsEntry 7 } otuc2StatisticsEntryUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { otuc2StatisticsEntry 8 } otuc3Statistics OBJECT IDENTIFIER ::= { otn 46 } otuc3StatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Otuc3StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { otuc3Statistics 1 } otuc3StatisticsEntry OBJECT-TYPE SYNTAX Otuc3StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otuc3StatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { otuc3StatisticsTable 1 } Otuc3StatisticsEntry ::= SEQUENCE { otuc3StatisticsEntryLastClear IetfYangTypesDateAndTime, otuc3StatisticsEntryLossOfSignalSeconds OCTET STRING, otuc3StatisticsEntryBitErrorFec OCTET STRING, otuc3StatisticsEntryUncorrectedBlockErrorFec OCTET STRING, otuc3StatisticsEntryErroredBlocks OCTET STRING, otuc3StatisticsEntryErroredSeconds OCTET STRING, otuc3StatisticsEntrySeverelyErroredSeconds OCTET STRING, otuc3StatisticsEntryUnavailableSeconds OCTET STRING } otuc3StatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { otuc3StatisticsEntry 1 } otuc3StatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { otuc3StatisticsEntry 2 } otuc3StatisticsEntryBitErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for error bit forward error correction, corresponding to pm parameter BE-FEC UNITS:bits " ::= { otuc3StatisticsEntry 3 } otuc3StatisticsEntryUncorrectedBlockErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics blocks counting for uncorrected block error forward error correction, corresponding to pm parameter UBE-FEC UNITS:blocks " ::= { otuc3StatisticsEntry 4 } otuc3StatisticsEntryErroredBlocks OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for errored blocks, corresponding to pm parameter EB UNITS:blocks " ::= { otuc3StatisticsEntry 5 } otuc3StatisticsEntryErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { otuc3StatisticsEntry 6 } otuc3StatisticsEntrySeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { otuc3StatisticsEntry 7 } otuc3StatisticsEntryUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { otuc3StatisticsEntry 8 } ochOsStatistics OBJECT IDENTIFIER ::= { otn 47 } ochOsStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF OchOsStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { ochOsStatistics 1 } ochOsStatisticsEntry OBJECT-TYPE SYNTAX OchOsStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ochOsStatisticsTable" INDEX { shelfId,slotId,subslotId,portId } ::= { ochOsStatisticsTable 1 } OchOsStatisticsEntry ::= SEQUENCE { ochOsStatisticsEntryLastClear IetfYangTypesDateAndTime, ochOsStatisticsEntryLossOfSignalSeconds OCTET STRING, ochOsStatisticsEntryBitErrorFec OCTET STRING, ochOsStatisticsEntryUncorrectedBlockErrorFec OCTET STRING } ochOsStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { ochOsStatisticsEntry 1 } ochOsStatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { ochOsStatisticsEntry 2 } ochOsStatisticsEntryBitErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for error bit forward error correction, corresponding to pm parameter BE-FEC UNITS:bits " ::= { ochOsStatisticsEntry 3 } ochOsStatisticsEntryUncorrectedBlockErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics blocks counting for uncorrected block error forward error correction, corresponding to pm parameter UBE-FEC UNITS:blocks " ::= { ochOsStatisticsEntry 4 } otuc6 OBJECT IDENTIFIER ::= { otn 48 } otuc6Table OBJECT-TYPE SYNTAX SEQUENCE OF Otuc6Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the otuc6 object" ::= { otuc6 1 } otuc6Entry OBJECT-TYPE SYNTAX Otuc6Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otuc6Table" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { otuc6Table 1 } Otuc6Entry ::= SEQUENCE { otuc6FecType CoriantTypesOtukFec, otuc6AdminStatus INTEGER, otuc6OperStatus INTEGER, otuc6AvailStatus BITS, otuc6AliasName OCTET STRING, otuc6ServiceLabel OCTET STRING, otuc6ExpSapi CoriantTypesTtiType15, otuc6ExpDapi CoriantTypesTtiType15, otuc6ExpOperator CoriantTypesTtiType32, otuc6TxSapi CoriantTypesTtiType15, otuc6TxDapi CoriantTypesTtiType15, otuc6TxOperator CoriantTypesTtiType32, otuc6TimDefectMode CoriantTypesTimMode, otuc6TimAct CoriantTypesEnableSwitch, otuc6RxSapi OCTET STRING, otuc6RxDapi OCTET STRING, otuc6RxOperator OCTET STRING, otuc6DegradeInterval Unsigned32, otuc6DegradeThreshold Unsigned32, otuc6ManagedBy INTEGER } otuc6FecType OBJECT-TYPE SYNTAX CoriantTypesOtukFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC type of client OTUk. Conditions:(ancestor::port/port-type = 'client') or (ancestor::port/port-type = 'client-subport') default value :G709" ::= { otuc6Entry 1 } otuc6AdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { otuc6Entry 2 } otuc6OperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { otuc6Entry 3 } otuc6AvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { otuc6Entry 4 } otuc6AliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { otuc6Entry 5 } otuc6ServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { otuc6Entry 6 } otuc6ExpSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected sapi(Source Access Point Identifier) " ::= { otuc6Entry 7 } otuc6ExpDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected dapi(Destination Access Point Identifier) " ::= { otuc6Entry 8 } otuc6ExpOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected operator TTI " ::= { otuc6Entry 9 } otuc6TxSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter sapi(Source Access Point Identifier) " ::= { otuc6Entry 10 } otuc6TxDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter dapi(Destination Access Point Identifier) " ::= { otuc6Entry 11 } otuc6TxOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter operator TTI " ::= { otuc6Entry 12 } otuc6TimDefectMode OBJECT-TYPE SYNTAX CoriantTypesTimMode MAX-ACCESS read-only STATUS current DESCRIPTION "The tim defect selection mode default value :NONE" ::= { otuc6Entry 13 } otuc6TimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { otuc6Entry 14 } otuc6RxSapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received sapi(Source Access Point Identifier) " ::= { otuc6Entry 15 } otuc6RxDapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received dapi(Destination Access Point Identifier) " ::= { otuc6Entry 16 } otuc6RxOperator OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received operator TTI " ::= { otuc6Entry 17 } otuc6DegradeInterval OBJECT-TYPE SYNTAX Unsigned32 (2..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The consecutive number of 1s intervals with the number of detected block errors exceeding the block error threshold for each of those seconds for the purposes of SDBER detection. default value :7" ::= { otuc6Entry 18 } otuc6DegradeThreshold OBJECT-TYPE SYNTAX Unsigned32 (1..2590845) MAX-ACCESS read-only STATUS current DESCRIPTION "The threshold number of block errors at which a 1s interval will be considered degraded for the purposes of SDBER detection. default value :777255" ::= { otuc6Entry 19 } otuc6ManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { otuc6Entry 20 } otuc6Statistics OBJECT IDENTIFIER ::= { otn 49 } otuc6StatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Otuc6StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { otuc6Statistics 1 } otuc6StatisticsEntry OBJECT-TYPE SYNTAX Otuc6StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otuc6StatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { otuc6StatisticsTable 1 } Otuc6StatisticsEntry ::= SEQUENCE { otuc6StatisticsEntryLastClear IetfYangTypesDateAndTime, otuc6StatisticsEntryLossOfSignalSeconds OCTET STRING, otuc6StatisticsEntryBitErrorFec OCTET STRING, otuc6StatisticsEntryUncorrectedBlockErrorFec OCTET STRING, otuc6StatisticsEntryErroredBlocks OCTET STRING, otuc6StatisticsEntryErroredSeconds OCTET STRING, otuc6StatisticsEntrySeverelyErroredSeconds OCTET STRING, otuc6StatisticsEntryUnavailableSeconds OCTET STRING } otuc6StatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { otuc6StatisticsEntry 1 } otuc6StatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { otuc6StatisticsEntry 2 } otuc6StatisticsEntryBitErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for error bit forward error correction, corresponding to pm parameter BE-FEC UNITS:bits " ::= { otuc6StatisticsEntry 3 } otuc6StatisticsEntryUncorrectedBlockErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics blocks counting for uncorrected block error forward error correction, corresponding to pm parameter UBE-FEC UNITS:blocks " ::= { otuc6StatisticsEntry 4 } otuc6StatisticsEntryErroredBlocks OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for errored blocks, corresponding to pm parameter EB UNITS:blocks " ::= { otuc6StatisticsEntry 5 } otuc6StatisticsEntryErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { otuc6StatisticsEntry 6 } otuc6StatisticsEntrySeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { otuc6StatisticsEntry 7 } otuc6StatisticsEntryUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { otuc6StatisticsEntry 8 } otuc4 OBJECT IDENTIFIER ::= { otn 50 } otuc4Table OBJECT-TYPE SYNTAX SEQUENCE OF Otuc4Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the otuc6 object" ::= { otuc4 1 } otuc4Entry OBJECT-TYPE SYNTAX Otuc4Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otuc4Table" INDEX { shelfId,slotId,subslotId,portId } ::= { otuc4Table 1 } Otuc4Entry ::= SEQUENCE { otuc4FecType CoriantTypesOtukFec, otuc4AdminStatus INTEGER, otuc4OperStatus INTEGER, otuc4AvailStatus BITS, otuc4AliasName OCTET STRING, otuc4ServiceLabel OCTET STRING, otuc4ExpSapi CoriantTypesTtiType15, otuc4ExpDapi CoriantTypesTtiType15, otuc4ExpOperator CoriantTypesTtiType32, otuc4TxSapi CoriantTypesTtiType15, otuc4TxDapi CoriantTypesTtiType15, otuc4TxOperator CoriantTypesTtiType32, otuc4TimDefectMode CoriantTypesTimMode, otuc4TimAct CoriantTypesEnableSwitch, otuc4RxSapi OCTET STRING, otuc4RxDapi OCTET STRING, otuc4RxOperator OCTET STRING, otuc4DegradeInterval Unsigned32, otuc4DegradeThreshold Unsigned32, otuc4ManagedBy INTEGER } otuc4FecType OBJECT-TYPE SYNTAX CoriantTypesOtukFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC type of client OTUk. Conditions:(ancestor::port/port-type = 'client') or (ancestor::port/port-type = 'client-subport') default value :G709" ::= { otuc4Entry 1 } otuc4AdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { otuc4Entry 2 } otuc4OperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { otuc4Entry 3 } otuc4AvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { otuc4Entry 4 } otuc4AliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { otuc4Entry 5 } otuc4ServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { otuc4Entry 6 } otuc4ExpSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected sapi(Source Access Point Identifier) " ::= { otuc4Entry 7 } otuc4ExpDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected dapi(Destination Access Point Identifier) " ::= { otuc4Entry 8 } otuc4ExpOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected operator TTI " ::= { otuc4Entry 9 } otuc4TxSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter sapi(Source Access Point Identifier) " ::= { otuc4Entry 10 } otuc4TxDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter dapi(Destination Access Point Identifier) " ::= { otuc4Entry 11 } otuc4TxOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter operator TTI " ::= { otuc4Entry 12 } otuc4TimDefectMode OBJECT-TYPE SYNTAX CoriantTypesTimMode MAX-ACCESS read-only STATUS current DESCRIPTION "The tim defect selection mode default value :NONE" ::= { otuc4Entry 13 } otuc4TimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { otuc4Entry 14 } otuc4RxSapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received sapi(Source Access Point Identifier) " ::= { otuc4Entry 15 } otuc4RxDapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received dapi(Destination Access Point Identifier) " ::= { otuc4Entry 16 } otuc4RxOperator OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received operator TTI " ::= { otuc4Entry 17 } otuc4DegradeInterval OBJECT-TYPE SYNTAX Unsigned32 (2..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The consecutive number of 1s intervals with the number of detected block errors exceeding the block error threshold for each of those seconds for the purposes of SDBER detection. default value :7" ::= { otuc4Entry 18 } otuc4DegradeThreshold OBJECT-TYPE SYNTAX Unsigned32 (1..2590845) MAX-ACCESS read-only STATUS current DESCRIPTION "The threshold number of block errors at which a 1s interval will be considered degraded for the purposes of SDBER detection. default value :518170" ::= { otuc4Entry 19 } otuc4ManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { otuc4Entry 20 } otuc4Statistics OBJECT IDENTIFIER ::= { otn 51 } otuc4StatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Otuc4StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { otuc4Statistics 1 } otuc4StatisticsEntry OBJECT-TYPE SYNTAX Otuc4StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otuc4StatisticsTable" INDEX { shelfId,slotId,subslotId,portId } ::= { otuc4StatisticsTable 1 } Otuc4StatisticsEntry ::= SEQUENCE { otuc4StatisticsEntryLastClear IetfYangTypesDateAndTime, otuc4StatisticsEntryLossOfSignalSeconds OCTET STRING, otuc4StatisticsEntryBitErrorFec OCTET STRING, otuc4StatisticsEntryUncorrectedBlockErrorFec OCTET STRING, otuc4StatisticsEntryErroredBlocks OCTET STRING, otuc4StatisticsEntryErroredSeconds OCTET STRING, otuc4StatisticsEntrySeverelyErroredSeconds OCTET STRING, otuc4StatisticsEntryUnavailableSeconds OCTET STRING } otuc4StatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { otuc4StatisticsEntry 1 } otuc4StatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { otuc4StatisticsEntry 2 } otuc4StatisticsEntryBitErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for error bit forward error correction, corresponding to pm parameter BE-FEC UNITS:bits " ::= { otuc4StatisticsEntry 3 } otuc4StatisticsEntryUncorrectedBlockErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics blocks counting for uncorrected block error forward error correction, corresponding to pm parameter UBE-FEC UNITS:blocks " ::= { otuc4StatisticsEntry 4 } otuc4StatisticsEntryErroredBlocks OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for errored blocks, corresponding to pm parameter EB UNITS:blocks " ::= { otuc4StatisticsEntry 5 } otuc4StatisticsEntryErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { otuc4StatisticsEntry 6 } otuc4StatisticsEntrySeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { otuc4StatisticsEntry 7 } otuc4StatisticsEntryUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { otuc4StatisticsEntry 8 } otuc5 OBJECT IDENTIFIER ::= { otn 52 } otuc5Table OBJECT-TYPE SYNTAX SEQUENCE OF Otuc5Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the otuc5 object" ::= { otuc5 1 } otuc5Entry OBJECT-TYPE SYNTAX Otuc5Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otuc5Table" INDEX { shelfId,slotId,subslotId,portId } ::= { otuc5Table 1 } Otuc5Entry ::= SEQUENCE { otuc5FecType CoriantTypesOtukFec, otuc5AdminStatus INTEGER, otuc5OperStatus INTEGER, otuc5AvailStatus BITS, otuc5AliasName OCTET STRING, otuc5ServiceLabel OCTET STRING, otuc5ExpSapi CoriantTypesTtiType15, otuc5ExpDapi CoriantTypesTtiType15, otuc5ExpOperator CoriantTypesTtiType32, otuc5TxSapi CoriantTypesTtiType15, otuc5TxDapi CoriantTypesTtiType15, otuc5TxOperator CoriantTypesTtiType32, otuc5TimDefectMode CoriantTypesTimMode, otuc5TimAct CoriantTypesEnableSwitch, otuc5RxSapi OCTET STRING, otuc5RxDapi OCTET STRING, otuc5RxOperator OCTET STRING, otuc5DegradeInterval Unsigned32, otuc5DegradeThreshold Unsigned32, otuc5ManagedBy INTEGER } otuc5FecType OBJECT-TYPE SYNTAX CoriantTypesOtukFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC type of client OTUk. Conditions:(ancestor::port/port-type = 'client') or (ancestor::port/port-type = 'client-subport') default value :G709" ::= { otuc5Entry 1 } otuc5AdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { otuc5Entry 2 } otuc5OperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { otuc5Entry 3 } otuc5AvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { otuc5Entry 4 } otuc5AliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { otuc5Entry 5 } otuc5ServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { otuc5Entry 6 } otuc5ExpSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected sapi(Source Access Point Identifier) " ::= { otuc5Entry 7 } otuc5ExpDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected dapi(Destination Access Point Identifier) " ::= { otuc5Entry 8 } otuc5ExpOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected operator TTI " ::= { otuc5Entry 9 } otuc5TxSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter sapi(Source Access Point Identifier) " ::= { otuc5Entry 10 } otuc5TxDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter dapi(Destination Access Point Identifier) " ::= { otuc5Entry 11 } otuc5TxOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter operator TTI " ::= { otuc5Entry 12 } otuc5TimDefectMode OBJECT-TYPE SYNTAX CoriantTypesTimMode MAX-ACCESS read-only STATUS current DESCRIPTION "The tim defect selection mode default value :NONE" ::= { otuc5Entry 13 } otuc5TimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { otuc5Entry 14 } otuc5RxSapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received sapi(Source Access Point Identifier) " ::= { otuc5Entry 15 } otuc5RxDapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received dapi(Destination Access Point Identifier) " ::= { otuc5Entry 16 } otuc5RxOperator OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received operator TTI " ::= { otuc5Entry 17 } otuc5DegradeInterval OBJECT-TYPE SYNTAX Unsigned32 (2..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The consecutive number of 1s intervals with the number of detected block errors exceeding the block error threshold for each of those seconds for the purposes of SDBER detection. default value :7" ::= { otuc5Entry 18 } otuc5DegradeThreshold OBJECT-TYPE SYNTAX Unsigned32 (1..2590845) MAX-ACCESS read-only STATUS current DESCRIPTION "The threshold number of block errors at which a 1s interval will be considered degraded for the purposes of SDBER detection. default value :647712" ::= { otuc5Entry 19 } otuc5ManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { otuc5Entry 20 } otuc5Statistics OBJECT IDENTIFIER ::= { otn 53 } otuc5StatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Otuc5StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { otuc5Statistics 1 } otuc5StatisticsEntry OBJECT-TYPE SYNTAX Otuc5StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otuc5StatisticsTable" INDEX { shelfId,slotId,subslotId,portId } ::= { otuc5StatisticsTable 1 } Otuc5StatisticsEntry ::= SEQUENCE { otuc5StatisticsEntryLastClear IetfYangTypesDateAndTime, otuc5StatisticsEntryLossOfSignalSeconds OCTET STRING, otuc5StatisticsEntryBitErrorFec OCTET STRING, otuc5StatisticsEntryUncorrectedBlockErrorFec OCTET STRING, otuc5StatisticsEntryErroredBlocks OCTET STRING, otuc5StatisticsEntryErroredSeconds OCTET STRING, otuc5StatisticsEntrySeverelyErroredSeconds OCTET STRING, otuc5StatisticsEntryUnavailableSeconds OCTET STRING } otuc5StatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { otuc5StatisticsEntry 1 } otuc5StatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { otuc5StatisticsEntry 2 } otuc5StatisticsEntryBitErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for error bit forward error correction, corresponding to pm parameter BE-FEC UNITS:bits " ::= { otuc5StatisticsEntry 3 } otuc5StatisticsEntryUncorrectedBlockErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics blocks counting for uncorrected block error forward error correction, corresponding to pm parameter UBE-FEC UNITS:blocks " ::= { otuc5StatisticsEntry 4 } otuc5StatisticsEntryErroredBlocks OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for errored blocks, corresponding to pm parameter EB UNITS:blocks " ::= { otuc5StatisticsEntry 5 } otuc5StatisticsEntryErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { otuc5StatisticsEntry 6 } otuc5StatisticsEntrySeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { otuc5StatisticsEntry 7 } otuc5StatisticsEntryUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { otuc5StatisticsEntry 8 } eth400g OBJECT IDENTIFIER ::= { otn 54 } eth400gTable OBJECT-TYPE SYNTAX SEQUENCE OF Eth400gEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the 400GBE object." ::= { eth400g 1 } eth400gEntry OBJECT-TYPE SYNTAX Eth400gEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of eth400gTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { eth400gTable 1 } Eth400gEntry ::= SEQUENCE { eth400gEthFecType CoriantTypesEthFec, eth400gEthFecTypeState CoriantTypesEthFec, eth400gTransmitInterpacketgap Unsigned32, eth400gGfpPayloadFcs CoriantTypesEnableSwitch, eth400gMappingMode INTEGER, eth400gAdminStatus INTEGER, eth400gOperStatus INTEGER, eth400gAvailStatus BITS, eth400gAliasName OCTET STRING, eth400gClientShutdown CoriantTypesYesNo, eth400gClientShutdownHoldoffTimer Unsigned32, eth400gHoldoffSignal CoriantTypesYesNo, eth400gNearEndAls CoriantTypesYesNo, eth400gAlsDegradeMode CoriantTypesEnableSwitch, eth400gLoopbackEnable CoriantTypesEnableSwitch, eth400gLoopbackType INTEGER, eth400gTestSignalType CoriantTypesTestSignalType, eth400gTestSignalEnable CoriantTypesTestSignalConfig, eth400gServiceLabel OCTET STRING, eth400gManagedBy INTEGER, eth400gLldpStatusIf INTEGER } eth400gEthFecType OBJECT-TYPE SYNTAX CoriantTypesEthFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC working type of etyn port. default value :auto" ::= { eth400gEntry 1 } eth400gEthFecTypeState OBJECT-TYPE SYNTAX CoriantTypesEthFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC working state of etyn port. default value :disabled" ::= { eth400gEntry 2 } eth400gTransmitInterpacketgap OBJECT-TYPE SYNTAX Unsigned32 (8..12) MAX-ACCESS read-only STATUS current DESCRIPTION " Specifies the minimum transmit IPG value. default value :8" ::= { eth400gEntry 3 } eth400gGfpPayloadFcs OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION " Enabled: GFP payload FCS will be used, Ethernet frame FCS will be removed; Disabled: GFP payload FCS will not be inserted, Ethernet frame FCS will be used. default value :disabled" ::= { eth400gEntry 4 } eth400gMappingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), gmp (1), gfpF (2), t40gbmpOdu2e (3), preamble (4), bmpFixedstuff (5), bmp (6), amp (7), tttGmp (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The mapping mode of client port packets into ODUk. default value :not-applicable" ::= { eth400gEntry 5 } eth400gAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { eth400gEntry 6 } eth400gOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { eth400gEntry 7 } eth400gAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { eth400gEntry 8 } eth400gAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { eth400gEntry 9 } eth400gClientShutdown OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of client-shutdown. default value :no" ::= { eth400gEntry 10 } eth400gClientShutdownHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The hold off time of client shutdown or replacement siganl at egress direction. UNITS:milliseconds default value :0" ::= { eth400gEntry 11 } eth400gHoldoffSignal OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Specify if specific signal will be sent out during hold off time which avoid downstream equipment consequent action in the duration. default value :no" ::= { eth400gEntry 12 } eth400gNearEndAls OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of near end ALS. default value :no" ::= { eth400gEntry 13 } eth400gAlsDegradeMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of defect BERSD-ODU trig ALS default value :disabled" ::= { eth400gEntry 14 } eth400gLoopbackEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of loopback function. default value :disabled" ::= { eth400gEntry 15 } eth400gLoopbackType OBJECT-TYPE SYNTAX INTEGER { none (0), terminal (1), facility (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of loopback function default value :none" ::= { eth400gEntry 16 } eth400gTestSignalType OBJECT-TYPE SYNTAX CoriantTypesTestSignalType MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of test signal. default value :NONE" ::= { eth400gEntry 17 } eth400gTestSignalEnable OBJECT-TYPE SYNTAX CoriantTypesTestSignalConfig MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of test signal function default value :NONE" ::= { eth400gEntry 18 } eth400gServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { eth400gEntry 19 } eth400gManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { eth400gEntry 20 } eth400gLldpStatusIf OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), rxonly (2), txandrx (3), disabled (4) } MAX-ACCESS read-only STATUS current DESCRIPTION " Port level lldp control. Value of 'rxonly', then the LLDP agent will receive lldp, when lldp-status-ne is also enabled. Value of 'disabled', then LLDP agent will not filter and receive LLDP frames on this port. If there is remote systems information which is received on this port and stored in the system before the lldp-status becomes disabled, then the information will naturally age out. Note: txOnly and txAndRx modes are not supported in Transponder module. default value :disabled" ::= { eth400gEntry 22 } eth400gStatistics OBJECT IDENTIFIER ::= { otn 55 } eth400gStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Eth400gStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { eth400gStatistics 1 } eth400gStatisticsEntry OBJECT-TYPE SYNTAX Eth400gStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of eth400gStatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { eth400gStatisticsTable 1 } Eth400gStatisticsEntry ::= SEQUENCE { eth400gStatisticsEntryLastClear IetfYangTypesDateAndTime, eth400gStatisticsEntryLossOfSignalSeconds OCTET STRING, eth400gStatisticsEntryBitErrorFec OCTET STRING, eth400gStatisticsEntryUncorrectedBlockErrorFec OCTET STRING, eth400gStatisticsEntryInSymbolErrors OCTET STRING, eth400gStatisticsEntryInDropEvents OCTET STRING, eth400gStatisticsEntryInOctets OCTET STRING, eth400gStatisticsEntryInPackets OCTET STRING, eth400gStatisticsEntryInBroadcastPackets OCTET STRING, eth400gStatisticsEntryInMulticastPackets OCTET STRING, eth400gStatisticsEntryInCrcAlignErrors OCTET STRING, eth400gStatisticsEntryInUndersizePackets OCTET STRING, eth400gStatisticsEntryInOversizePackets OCTET STRING, eth400gStatisticsEntryInFragments OCTET STRING, eth400gStatisticsEntryInJabbers OCTET STRING, eth400gStatisticsEntryInPackets64octets OCTET STRING, eth400gStatisticsEntryInPackets65to127octets OCTET STRING, eth400gStatisticsEntryInPackets128to255octets OCTET STRING, eth400gStatisticsEntryInPackets256to511octets OCTET STRING, eth400gStatisticsEntryInPackets512to1023octets OCTET STRING, eth400gStatisticsEntryInPackets1024to1518octets OCTET STRING, eth400gStatisticsEntryOutSymbolErrors OCTET STRING, eth400gStatisticsEntryOutDropEvents OCTET STRING, eth400gStatisticsEntryOutOctets OCTET STRING, eth400gStatisticsEntryOutPackets OCTET STRING, eth400gStatisticsEntryOutBroadcastPackets OCTET STRING, eth400gStatisticsEntryOutMulticastPackets OCTET STRING, eth400gStatisticsEntryOutCrcAlignErrors OCTET STRING, eth400gStatisticsEntryOutUndersizePackets OCTET STRING, eth400gStatisticsEntryOutOversizePackets OCTET STRING, eth400gStatisticsEntryOutFragments OCTET STRING, eth400gStatisticsEntryOutJabbers OCTET STRING, eth400gStatisticsEntryOutPackets64octets OCTET STRING, eth400gStatisticsEntryOutPackets65to127octets OCTET STRING, eth400gStatisticsEntryOutPackets128to255octets OCTET STRING, eth400gStatisticsEntryOutPackets256to511octets OCTET STRING, eth400gStatisticsEntryOutPackets512to1023octets OCTET STRING, eth400gStatisticsEntryOutPackets1024to1518octets OCTET STRING, eth400gStatisticsEntryInCodingViolation OCTET STRING, eth400gStatisticsEntryErroredSeconds OCTET STRING, eth400gStatisticsEntrySeverelyErroredSeconds OCTET STRING, eth400gStatisticsEntryUnavailableSeconds OCTET STRING } eth400gStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { eth400gStatisticsEntry 1 } eth400gStatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { eth400gStatisticsEntry 2 } eth400gStatisticsEntryBitErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for error bit forward error correction, corresponding to pm parameter BE-FEC UNITS:bits " ::= { eth400gStatisticsEntry 3 } eth400gStatisticsEntryUncorrectedBlockErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics blocks counting for uncorrected block error forward error correction, corresponding to pm parameter UBE-FEC UNITS:blocks " ::= { eth400gStatisticsEntry 4 } eth400gStatisticsEntryInSymbolErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics Times counting for input signal symbol errors, corresponding to pm parameter SE UNITS:Events " ::= { eth400gStatisticsEntry 5 } eth400gStatisticsEntryInDropEvents OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input signal drop events, corresponding to pm parameter DropEvents UNITS:events " ::= { eth400gStatisticsEntry 6 } eth400gStatisticsEntryInOctets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input signal octets, corresponding to pm parameter Octets UNITS:octets " ::= { eth400gStatisticsEntry 7 } eth400gStatisticsEntryInPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input signal packets, corresponding to pm parameter Pkts UNITS:packets " ::= { eth400gStatisticsEntry 8 } eth400gStatisticsEntryInBroadcastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input broadcast packets, corresponding to pm parameter BroadcastPkts UNITS:packets " ::= { eth400gStatisticsEntry 9 } eth400gStatisticsEntryInMulticastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input multicast packets, corresponding to pm parameter MulticastPkts UNITS:packets " ::= { eth400gStatisticsEntry 10 } eth400gStatisticsEntryInCrcAlignErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input CRC error packets, corresponding to pm parameter CRCAlignErrors UNITS:packets " ::= { eth400gStatisticsEntry 11 } eth400gStatisticsEntryInUndersizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input undersize packets, corresponding to pm parameter UndersizePkts UNITS:packets " ::= { eth400gStatisticsEntry 12 } eth400gStatisticsEntryInOversizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input oversize packets, corresponding to pm parameter OversizePkts UNITS:packets " ::= { eth400gStatisticsEntry 13 } eth400gStatisticsEntryInFragments OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input fragment packets, corresponding to pm parameter Fragments UNITS:packets " ::= { eth400gStatisticsEntry 14 } eth400gStatisticsEntryInJabbers OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input jabber packets, corresponding to pm parameter Jabbers UNITS:packets " ::= { eth400gStatisticsEntry 15 } eth400gStatisticsEntryInPackets64octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 64 octets packets, corresponding to pm parameter Pkts64Octets UNITS:packets " ::= { eth400gStatisticsEntry 16 } eth400gStatisticsEntryInPackets65to127octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 65 to 127 octets packets, corresponding to pm parameter Pkts65to127Octets UNITS:packets " ::= { eth400gStatisticsEntry 17 } eth400gStatisticsEntryInPackets128to255octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 128 to 255 octets packets, corresponding to pm parameter Pkts128to255Octets UNITS:packets " ::= { eth400gStatisticsEntry 18 } eth400gStatisticsEntryInPackets256to511octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 256 to 511 octets packets, corresponding to pm parameter Pkts256to511Octets UNITS:packets " ::= { eth400gStatisticsEntry 19 } eth400gStatisticsEntryInPackets512to1023octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 512 to 1023 octets packets, corresponding to pm parameter Pkts512to1023Octets UNITS:packets " ::= { eth400gStatisticsEntry 20 } eth400gStatisticsEntryInPackets1024to1518octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 1024 to 1518 octets packets, corresponding to pm parameter Pkts1024to1518Octets UNITS:packets " ::= { eth400gStatisticsEntry 21 } eth400gStatisticsEntryOutSymbolErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics Times counting for output signal symbol errors, corresponding to pm parameter SE UNITS:Events " ::= { eth400gStatisticsEntry 22 } eth400gStatisticsEntryOutDropEvents OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output signal drop events, corresponding to pm parameter DropEvents UNITS:events " ::= { eth400gStatisticsEntry 23 } eth400gStatisticsEntryOutOctets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output signal octets, corresponding to pm parameter Octets UNITS:octets " ::= { eth400gStatisticsEntry 24 } eth400gStatisticsEntryOutPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output signal packets, corresponding to pm parameter Pkts UNITS:packets " ::= { eth400gStatisticsEntry 25 } eth400gStatisticsEntryOutBroadcastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output broadcast packets, corresponding to pm parameter BroadcastPkts UNITS:packets " ::= { eth400gStatisticsEntry 26 } eth400gStatisticsEntryOutMulticastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output multicast packets, corresponding to pm parameter MulticastPkts UNITS:packets " ::= { eth400gStatisticsEntry 27 } eth400gStatisticsEntryOutCrcAlignErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output CRC error packets, corresponding to pm parameter CRCAlignErrors UNITS:packets " ::= { eth400gStatisticsEntry 28 } eth400gStatisticsEntryOutUndersizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output undersize packets, corresponding to pm parameter UndersizePkts UNITS:packets " ::= { eth400gStatisticsEntry 29 } eth400gStatisticsEntryOutOversizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output oversize packets, corresponding to pm parameter OversizePkts UNITS:packets " ::= { eth400gStatisticsEntry 30 } eth400gStatisticsEntryOutFragments OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output fragment packets, corresponding to pm parameter Fragments UNITS:packets " ::= { eth400gStatisticsEntry 31 } eth400gStatisticsEntryOutJabbers OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output jabber packets, corresponding to pm parameter Jabbers UNITS:packets " ::= { eth400gStatisticsEntry 32 } eth400gStatisticsEntryOutPackets64octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 64 octets packets, corresponding to pm parameter Pkts64Octets UNITS:packets " ::= { eth400gStatisticsEntry 33 } eth400gStatisticsEntryOutPackets65to127octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 65 to 127 octets packets, corresponding to pm parameter Pkts65to127Octets UNITS:packets " ::= { eth400gStatisticsEntry 34 } eth400gStatisticsEntryOutPackets128to255octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 128 to 255 octets packets, corresponding to pm parameter Pkts128to255Octets UNITS:packets " ::= { eth400gStatisticsEntry 35 } eth400gStatisticsEntryOutPackets256to511octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 256 to 511 octets packets, corresponding to pm parameter Pkts256to511Octets UNITS:packets " ::= { eth400gStatisticsEntry 36 } eth400gStatisticsEntryOutPackets512to1023octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 512 to 1023 octets packets, corresponding to pm parameter Pkts512to1023Octets UNITS:packets " ::= { eth400gStatisticsEntry 37 } eth400gStatisticsEntryOutPackets1024to1518octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 1024 to 1518 octets packets, corresponding to pm parameter Pkts1024to1518Octets UNITS:packets " ::= { eth400gStatisticsEntry 38 } eth400gStatisticsEntryInCodingViolation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for ingress coding violation, corresponding to pm parameter CV UNITS:bits " ::= { eth400gStatisticsEntry 39 } eth400gStatisticsEntryErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { eth400gStatisticsEntry 40 } eth400gStatisticsEntrySeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { eth400gStatisticsEntry 41 } eth400gStatisticsEntryUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { eth400gStatisticsEntry 42 } oc48 OBJECT IDENTIFIER ::= { otn 56 } oc48Table OBJECT-TYPE SYNTAX SEQUENCE OF Oc48Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Represents the OC48 object. " ::= { oc48 1 } oc48Entry OBJECT-TYPE SYNTAX Oc48Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of oc48Table" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { oc48Table 1 } Oc48Entry ::= SEQUENCE { oc48MappingMode INTEGER, oc48AdminStatus INTEGER, oc48OperStatus INTEGER, oc48AvailStatus BITS, oc48AliasName OCTET STRING, oc48ClientShutdown CoriantTypesYesNo, oc48ClientShutdownHoldoffTimer Unsigned32, oc48HoldoffSignal CoriantTypesYesNo, oc48NearEndAls CoriantTypesYesNo, oc48AlsDegradeMode CoriantTypesEnableSwitch, oc48LoopbackEnable CoriantTypesEnableSwitch, oc48LoopbackType INTEGER, oc48TestSignalType CoriantTypesTestSignalType, oc48TestSignalEnable CoriantTypesTestSignalConfig, oc48ServiceLabel OCTET STRING, oc48ManagedBy INTEGER, oc48ExpTrc CoriantTypesTtiType15, oc48TxTrc CoriantTypesTtiType15, oc48RxTrc OCTET STRING, oc48TimAct CoriantTypesEnableSwitch, oc48TimMonitor CoriantTypesEnableSwitch, oc48AisType INTEGER } oc48MappingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), gmp (1), gfpF (2), t40gbmpOdu2e (3), preamble (4), bmpFixedstuff (5), bmp (6), amp (7), tttGmp (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The mapping mode of client port packets into ODUk. default value :not-applicable" ::= { oc48Entry 1 } oc48AdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { oc48Entry 2 } oc48OperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { oc48Entry 3 } oc48AvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { oc48Entry 4 } oc48AliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { oc48Entry 5 } oc48ClientShutdown OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of client-shutdown. default value :no" ::= { oc48Entry 6 } oc48ClientShutdownHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The hold off time of client shutdown or replacement siganl at egress direction. UNITS:milliseconds default value :0" ::= { oc48Entry 7 } oc48HoldoffSignal OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Specify if specific signal will be sent out during hold off time which avoid downstream equipment consequent action in the duration. default value :no" ::= { oc48Entry 8 } oc48NearEndAls OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of near end ALS. default value :no" ::= { oc48Entry 9 } oc48AlsDegradeMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of defect BERSD-ODU trig ALS default value :disabled" ::= { oc48Entry 10 } oc48LoopbackEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of loopback function. default value :disabled" ::= { oc48Entry 11 } oc48LoopbackType OBJECT-TYPE SYNTAX INTEGER { none (0), terminal (1), facility (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of loopback function default value :none" ::= { oc48Entry 12 } oc48TestSignalType OBJECT-TYPE SYNTAX CoriantTypesTestSignalType MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of test signal. default value :NONE" ::= { oc48Entry 13 } oc48TestSignalEnable OBJECT-TYPE SYNTAX CoriantTypesTestSignalConfig MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of test signal function default value :NONE" ::= { oc48Entry 14 } oc48ServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { oc48Entry 15 } oc48ManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { oc48Entry 16 } oc48ExpTrc OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected trc(trail trace identification) " ::= { oc48Entry 17 } oc48TxTrc OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter trc(trail trace identification) Conditions:ancestor::card/switching-type = 'tdm' " ::= { oc48Entry 18 } oc48RxTrc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received trc(trail trace identification) " ::= { oc48Entry 19 } oc48TimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { oc48Entry 20 } oc48TimMonitor OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of tim defect monitor mode default value :disabled" ::= { oc48Entry 21 } oc48AisType OBJECT-TYPE SYNTAX INTEGER { genericAis (0), msAis (1), aisL (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL default value :Generic-AIS" ::= { oc48Entry 22 } oc48Statistics OBJECT IDENTIFIER ::= { otn 57 } oc48StatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Oc48StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { oc48Statistics 1 } oc48StatisticsEntry OBJECT-TYPE SYNTAX Oc48StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of oc48StatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { oc48StatisticsTable 1 } Oc48StatisticsEntry ::= SEQUENCE { oc48StatisticsEntryLastClear IetfYangTypesDateAndTime, oc48StatisticsEntryLossOfSignalSeconds OCTET STRING, oc48StatisticsEntryInCodingViolation OCTET STRING, oc48StatisticsEntryInErroredSeconds OCTET STRING, oc48StatisticsEntryInSeverelyErroredSeconds OCTET STRING, oc48StatisticsEntryInUnavailableSeconds OCTET STRING, oc48StatisticsEntryInSeverelyErroredFrameSecond OCTET STRING } oc48StatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { oc48StatisticsEntry 1 } oc48StatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { oc48StatisticsEntry 2 } oc48StatisticsEntryInCodingViolation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for ingress coding violation, corresponding to pm parameter CV UNITS:bits " ::= { oc48StatisticsEntry 3 } oc48StatisticsEntryInErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { oc48StatisticsEntry 4 } oc48StatisticsEntryInSeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { oc48StatisticsEntry 5 } oc48StatisticsEntryInUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { oc48StatisticsEntry 6 } oc48StatisticsEntryInSeverelyErroredFrameSecond OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for ingress signal frame severely errored, corresponding to pm parameter SEFS UNITS:seconds " ::= { oc48StatisticsEntry 7 } stm16 OBJECT IDENTIFIER ::= { otn 58 } stm16Table OBJECT-TYPE SYNTAX SEQUENCE OF Stm16Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Represents the STM16 object. " ::= { stm16 1 } stm16Entry OBJECT-TYPE SYNTAX Stm16Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of stm16Table" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { stm16Table 1 } Stm16Entry ::= SEQUENCE { stm16MappingMode INTEGER, stm16AdminStatus INTEGER, stm16OperStatus INTEGER, stm16AvailStatus BITS, stm16AliasName OCTET STRING, stm16ClientShutdown CoriantTypesYesNo, stm16ClientShutdownHoldoffTimer Unsigned32, stm16HoldoffSignal CoriantTypesYesNo, stm16NearEndAls CoriantTypesYesNo, stm16AlsDegradeMode CoriantTypesEnableSwitch, stm16LoopbackEnable CoriantTypesEnableSwitch, stm16LoopbackType INTEGER, stm16TestSignalType CoriantTypesTestSignalType, stm16TestSignalEnable CoriantTypesTestSignalConfig, stm16ServiceLabel OCTET STRING, stm16ManagedBy INTEGER, stm16ExpTrc CoriantTypesTtiType15, stm16TxTrc CoriantTypesTtiType15, stm16RxTrc OCTET STRING, stm16TimAct CoriantTypesEnableSwitch, stm16TimMonitor CoriantTypesEnableSwitch, stm16AisType INTEGER } stm16MappingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), gmp (1), gfpF (2), t40gbmpOdu2e (3), preamble (4), bmpFixedstuff (5), bmp (6), amp (7), tttGmp (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The mapping mode of client port packets into ODUk. default value :not-applicable" ::= { stm16Entry 1 } stm16AdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { stm16Entry 2 } stm16OperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { stm16Entry 3 } stm16AvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { stm16Entry 4 } stm16AliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { stm16Entry 5 } stm16ClientShutdown OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of client-shutdown. default value :no" ::= { stm16Entry 6 } stm16ClientShutdownHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The hold off time of client shutdown or replacement siganl at egress direction. UNITS:milliseconds default value :0" ::= { stm16Entry 7 } stm16HoldoffSignal OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Specify if specific signal will be sent out during hold off time which avoid downstream equipment consequent action in the duration. default value :no" ::= { stm16Entry 8 } stm16NearEndAls OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of near end ALS. default value :no" ::= { stm16Entry 9 } stm16AlsDegradeMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of defect BERSD-ODU trig ALS default value :disabled" ::= { stm16Entry 10 } stm16LoopbackEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of loopback function. default value :disabled" ::= { stm16Entry 11 } stm16LoopbackType OBJECT-TYPE SYNTAX INTEGER { none (0), terminal (1), facility (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of loopback function default value :none" ::= { stm16Entry 12 } stm16TestSignalType OBJECT-TYPE SYNTAX CoriantTypesTestSignalType MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of test signal. default value :NONE" ::= { stm16Entry 13 } stm16TestSignalEnable OBJECT-TYPE SYNTAX CoriantTypesTestSignalConfig MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of test signal function default value :NONE" ::= { stm16Entry 14 } stm16ServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { stm16Entry 15 } stm16ManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { stm16Entry 16 } stm16ExpTrc OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected trc(trail trace identification) " ::= { stm16Entry 17 } stm16TxTrc OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter trc(trail trace identification) Conditions:ancestor::card/switching-type = 'tdm' " ::= { stm16Entry 18 } stm16RxTrc OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received trc(trail trace identification) " ::= { stm16Entry 19 } stm16TimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { stm16Entry 20 } stm16TimMonitor OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of tim defect monitor mode default value :disabled" ::= { stm16Entry 21 } stm16AisType OBJECT-TYPE SYNTAX INTEGER { genericAis (0), msAis (1), aisL (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL default value :Generic-AIS" ::= { stm16Entry 22 } stm16Statistics OBJECT IDENTIFIER ::= { otn 59 } stm16StatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Stm16StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { stm16Statistics 1 } stm16StatisticsEntry OBJECT-TYPE SYNTAX Stm16StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of stm16StatisticsTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { stm16StatisticsTable 1 } Stm16StatisticsEntry ::= SEQUENCE { stm16StatisticsEntryLastClear IetfYangTypesDateAndTime, stm16StatisticsEntryLossOfSignalSeconds OCTET STRING, stm16StatisticsEntryInBackgroundBlockError OCTET STRING, stm16StatisticsEntryInErroredSeconds OCTET STRING, stm16StatisticsEntryInSeverelyErroredSeconds OCTET STRING, stm16StatisticsEntryInUnavailableSeconds OCTET STRING, stm16StatisticsEntryInOutOfFrameSeconds OCTET STRING } stm16StatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { stm16StatisticsEntry 1 } stm16StatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { stm16StatisticsEntry 2 } stm16StatisticsEntryInBackgroundBlockError OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for ingress errored blocks, corresponding to pm parameter BBE UNITS:blocks " ::= { stm16StatisticsEntry 3 } stm16StatisticsEntryInErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { stm16StatisticsEntry 4 } stm16StatisticsEntryInSeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { stm16StatisticsEntry 5 } stm16StatisticsEntryInUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for RX unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { stm16StatisticsEntry 6 } stm16StatisticsEntryInOutOfFrameSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for ingress signal lose of frame, corresponding to pm parameter OFS UNITS:seconds " ::= { stm16StatisticsEntry 7 } otuc7 OBJECT IDENTIFIER ::= { otn 60 } otuc7Table OBJECT-TYPE SYNTAX SEQUENCE OF Otuc7Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the otuc7 object" ::= { otuc7 1 } otuc7Entry OBJECT-TYPE SYNTAX Otuc7Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otuc7Table" INDEX { shelfId,slotId,subslotId,portId } ::= { otuc7Table 1 } Otuc7Entry ::= SEQUENCE { otuc7FecType CoriantTypesOtukFec, otuc7AdminStatus INTEGER, otuc7OperStatus INTEGER, otuc7AvailStatus BITS, otuc7AliasName OCTET STRING, otuc7ServiceLabel OCTET STRING, otuc7ExpSapi CoriantTypesTtiType15, otuc7ExpDapi CoriantTypesTtiType15, otuc7ExpOperator CoriantTypesTtiType32, otuc7TxSapi CoriantTypesTtiType15, otuc7TxDapi CoriantTypesTtiType15, otuc7TxOperator CoriantTypesTtiType32, otuc7TimDefectMode CoriantTypesTimMode, otuc7TimAct CoriantTypesEnableSwitch, otuc7RxSapi OCTET STRING, otuc7RxDapi OCTET STRING, otuc7RxOperator OCTET STRING, otuc7ManagedBy INTEGER, otuc7DegradeInterval Unsigned32, otuc7DegradeThreshold Unsigned32 } otuc7FecType OBJECT-TYPE SYNTAX CoriantTypesOtukFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC type of client OTUk. Conditions:(ancestor::port/port-type = 'client') or (ancestor::port/port-type = 'client-subport') default value :G709" ::= { otuc7Entry 1 } otuc7AdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { otuc7Entry 2 } otuc7OperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { otuc7Entry 3 } otuc7AvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { otuc7Entry 4 } otuc7AliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { otuc7Entry 5 } otuc7ServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { otuc7Entry 6 } otuc7ExpSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected sapi(Source Access Point Identifier) " ::= { otuc7Entry 7 } otuc7ExpDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected dapi(Destination Access Point Identifier) " ::= { otuc7Entry 8 } otuc7ExpOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected operator TTI " ::= { otuc7Entry 9 } otuc7TxSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter sapi(Source Access Point Identifier) " ::= { otuc7Entry 10 } otuc7TxDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter dapi(Destination Access Point Identifier) " ::= { otuc7Entry 11 } otuc7TxOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter operator TTI " ::= { otuc7Entry 12 } otuc7TimDefectMode OBJECT-TYPE SYNTAX CoriantTypesTimMode MAX-ACCESS read-only STATUS current DESCRIPTION "The tim defect selection mode default value :NONE" ::= { otuc7Entry 13 } otuc7TimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { otuc7Entry 14 } otuc7RxSapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received sapi(Source Access Point Identifier) " ::= { otuc7Entry 15 } otuc7RxDapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received dapi(Destination Access Point Identifier) " ::= { otuc7Entry 16 } otuc7RxOperator OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received operator TTI " ::= { otuc7Entry 17 } otuc7ManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { otuc7Entry 18 } otuc7DegradeInterval OBJECT-TYPE SYNTAX Unsigned32 (2..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The consecutive number of 1s intervals with the number of detected block errors exceeding the block error threshold for each of those seconds for the purposes of SDBER detection. default value :7" ::= { otuc7Entry 19 } otuc7DegradeThreshold OBJECT-TYPE SYNTAX Unsigned32 (1..2590845) MAX-ACCESS read-only STATUS current DESCRIPTION "The threshold number of block errors at which a 1s interval will be considered degraded for the purposes of SDBER detection. default value :906797" ::= { otuc7Entry 20 } otuc7Statistics OBJECT IDENTIFIER ::= { otn 61 } otuc7StatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Otuc7StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { otuc7Statistics 1 } otuc7StatisticsEntry OBJECT-TYPE SYNTAX Otuc7StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otuc7StatisticsTable" INDEX { shelfId,slotId,subslotId,portId } ::= { otuc7StatisticsTable 1 } Otuc7StatisticsEntry ::= SEQUENCE { otuc7StatisticsEntryLastClear IetfYangTypesDateAndTime, otuc7StatisticsEntryLossOfSignalSeconds OCTET STRING, otuc7StatisticsEntryBitErrorFec OCTET STRING, otuc7StatisticsEntryUncorrectedBlockErrorFec OCTET STRING, otuc7StatisticsEntryErroredBlocks OCTET STRING, otuc7StatisticsEntryErroredSeconds OCTET STRING, otuc7StatisticsEntrySeverelyErroredSeconds OCTET STRING, otuc7StatisticsEntryUnavailableSeconds OCTET STRING } otuc7StatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { otuc7StatisticsEntry 1 } otuc7StatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { otuc7StatisticsEntry 2 } otuc7StatisticsEntryBitErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for error bit forward error correction, corresponding to pm parameter BE-FEC UNITS:bits " ::= { otuc7StatisticsEntry 3 } otuc7StatisticsEntryUncorrectedBlockErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics blocks counting for uncorrected block error forward error correction, corresponding to pm parameter UBE-FEC UNITS:blocks " ::= { otuc7StatisticsEntry 4 } otuc7StatisticsEntryErroredBlocks OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for errored blocks, corresponding to pm parameter EB UNITS:blocks " ::= { otuc7StatisticsEntry 5 } otuc7StatisticsEntryErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { otuc7StatisticsEntry 6 } otuc7StatisticsEntrySeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { otuc7StatisticsEntry 7 } otuc7StatisticsEntryUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { otuc7StatisticsEntry 8 } otuc9 OBJECT IDENTIFIER ::= { otn 62 } otuc9Table OBJECT-TYPE SYNTAX SEQUENCE OF Otuc9Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the otuc9 object" ::= { otuc9 1 } otuc9Entry OBJECT-TYPE SYNTAX Otuc9Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otuc9Table" INDEX { shelfId,slotId,subslotId,portId } ::= { otuc9Table 1 } Otuc9Entry ::= SEQUENCE { otuc9FecType CoriantTypesOtukFec, otuc9AdminStatus INTEGER, otuc9OperStatus INTEGER, otuc9AvailStatus BITS, otuc9AliasName OCTET STRING, otuc9ServiceLabel OCTET STRING, otuc9ExpSapi CoriantTypesTtiType15, otuc9ExpDapi CoriantTypesTtiType15, otuc9ExpOperator CoriantTypesTtiType32, otuc9TxSapi CoriantTypesTtiType15, otuc9TxDapi CoriantTypesTtiType15, otuc9TxOperator CoriantTypesTtiType32, otuc9TimDefectMode CoriantTypesTimMode, otuc9TimAct CoriantTypesEnableSwitch, otuc9RxSapi OCTET STRING, otuc9RxDapi OCTET STRING, otuc9RxOperator OCTET STRING, otuc9ManagedBy INTEGER, otuc9DegradeInterval Unsigned32, otuc9DegradeThreshold Unsigned32 } otuc9FecType OBJECT-TYPE SYNTAX CoriantTypesOtukFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC type of client OTUk. Conditions:(ancestor::port/port-type = 'client') or (ancestor::port/port-type = 'client-subport') default value :G709" ::= { otuc9Entry 1 } otuc9AdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { otuc9Entry 2 } otuc9OperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { otuc9Entry 3 } otuc9AvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { otuc9Entry 4 } otuc9AliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { otuc9Entry 5 } otuc9ServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { otuc9Entry 6 } otuc9ExpSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected sapi(Source Access Point Identifier) " ::= { otuc9Entry 7 } otuc9ExpDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected dapi(Destination Access Point Identifier) " ::= { otuc9Entry 8 } otuc9ExpOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected operator TTI " ::= { otuc9Entry 9 } otuc9TxSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter sapi(Source Access Point Identifier) " ::= { otuc9Entry 10 } otuc9TxDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter dapi(Destination Access Point Identifier) " ::= { otuc9Entry 11 } otuc9TxOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter operator TTI " ::= { otuc9Entry 12 } otuc9TimDefectMode OBJECT-TYPE SYNTAX CoriantTypesTimMode MAX-ACCESS read-only STATUS current DESCRIPTION "The tim defect selection mode default value :NONE" ::= { otuc9Entry 13 } otuc9TimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { otuc9Entry 14 } otuc9RxSapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received sapi(Source Access Point Identifier) " ::= { otuc9Entry 15 } otuc9RxDapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received dapi(Destination Access Point Identifier) " ::= { otuc9Entry 16 } otuc9RxOperator OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received operator TTI " ::= { otuc9Entry 17 } otuc9ManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { otuc9Entry 18 } otuc9DegradeInterval OBJECT-TYPE SYNTAX Unsigned32 (2..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The consecutive number of 1s intervals with the number of detected block errors exceeding the block error threshold for each of those seconds for the purposes of SDBER detection. default value :7" ::= { otuc9Entry 19 } otuc9DegradeThreshold OBJECT-TYPE SYNTAX Unsigned32 (1..2590845) MAX-ACCESS read-only STATUS current DESCRIPTION "The threshold number of block errors at which a 1s interval will be considered degraded for the purposes of SDBER detection. default value :1165881" ::= { otuc9Entry 20 } otuc9Statistics OBJECT IDENTIFIER ::= { otn 63 } otuc9StatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Otuc9StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { otuc9Statistics 1 } otuc9StatisticsEntry OBJECT-TYPE SYNTAX Otuc9StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otuc9StatisticsTable" INDEX { shelfId,slotId,subslotId,portId } ::= { otuc9StatisticsTable 1 } Otuc9StatisticsEntry ::= SEQUENCE { otuc9StatisticsEntryLastClear IetfYangTypesDateAndTime, otuc9StatisticsEntryLossOfSignalSeconds OCTET STRING, otuc9StatisticsEntryBitErrorFec OCTET STRING, otuc9StatisticsEntryUncorrectedBlockErrorFec OCTET STRING, otuc9StatisticsEntryErroredBlocks OCTET STRING, otuc9StatisticsEntryErroredSeconds OCTET STRING, otuc9StatisticsEntrySeverelyErroredSeconds OCTET STRING, otuc9StatisticsEntryUnavailableSeconds OCTET STRING } otuc9StatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { otuc9StatisticsEntry 1 } otuc9StatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { otuc9StatisticsEntry 2 } otuc9StatisticsEntryBitErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for error bit forward error correction, corresponding to pm parameter BE-FEC UNITS:bits " ::= { otuc9StatisticsEntry 3 } otuc9StatisticsEntryUncorrectedBlockErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics blocks counting for uncorrected block error forward error correction, corresponding to pm parameter UBE-FEC UNITS:blocks " ::= { otuc9StatisticsEntry 4 } otuc9StatisticsEntryErroredBlocks OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for errored blocks, corresponding to pm parameter EB UNITS:blocks " ::= { otuc9StatisticsEntry 5 } otuc9StatisticsEntryErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { otuc9StatisticsEntry 6 } otuc9StatisticsEntrySeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { otuc9StatisticsEntry 7 } otuc9StatisticsEntryUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { otuc9StatisticsEntry 8 } otuc11 OBJECT IDENTIFIER ::= { otn 64 } otuc11Table OBJECT-TYPE SYNTAX SEQUENCE OF Otuc11Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the otuc11 object" ::= { otuc11 1 } otuc11Entry OBJECT-TYPE SYNTAX Otuc11Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otuc11Table" INDEX { shelfId,slotId,subslotId,portId } ::= { otuc11Table 1 } Otuc11Entry ::= SEQUENCE { otuc11FecType CoriantTypesOtukFec, otuc11AdminStatus INTEGER, otuc11OperStatus INTEGER, otuc11AvailStatus BITS, otuc11AliasName OCTET STRING, otuc11ServiceLabel OCTET STRING, otuc11ExpSapi CoriantTypesTtiType15, otuc11ExpDapi CoriantTypesTtiType15, otuc11ExpOperator CoriantTypesTtiType32, otuc11TxSapi CoriantTypesTtiType15, otuc11TxDapi CoriantTypesTtiType15, otuc11TxOperator CoriantTypesTtiType32, otuc11TimDefectMode CoriantTypesTimMode, otuc11TimAct CoriantTypesEnableSwitch, otuc11RxSapi OCTET STRING, otuc11RxDapi OCTET STRING, otuc11RxOperator OCTET STRING, otuc11ManagedBy INTEGER, otuc11DegradeInterval Unsigned32, otuc11DegradeThreshold Unsigned32 } otuc11FecType OBJECT-TYPE SYNTAX CoriantTypesOtukFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC type of client OTUk. Conditions:(ancestor::port/port-type = 'client') or (ancestor::port/port-type = 'client-subport') default value :G709" ::= { otuc11Entry 1 } otuc11AdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { otuc11Entry 2 } otuc11OperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { otuc11Entry 3 } otuc11AvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { otuc11Entry 4 } otuc11AliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { otuc11Entry 5 } otuc11ServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { otuc11Entry 6 } otuc11ExpSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected sapi(Source Access Point Identifier) " ::= { otuc11Entry 7 } otuc11ExpDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected dapi(Destination Access Point Identifier) " ::= { otuc11Entry 8 } otuc11ExpOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The expected operator TTI " ::= { otuc11Entry 9 } otuc11TxSapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter sapi(Source Access Point Identifier) " ::= { otuc11Entry 10 } otuc11TxDapi OBJECT-TYPE SYNTAX CoriantTypesTtiType15 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter dapi(Destination Access Point Identifier) " ::= { otuc11Entry 11 } otuc11TxOperator OBJECT-TYPE SYNTAX CoriantTypesTtiType32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter operator TTI " ::= { otuc11Entry 12 } otuc11TimDefectMode OBJECT-TYPE SYNTAX CoriantTypesTimMode MAX-ACCESS read-only STATUS current DESCRIPTION "The tim defect selection mode default value :NONE" ::= { otuc11Entry 13 } otuc11TimAct OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of inserting AIS by tim function default value :disabled" ::= { otuc11Entry 14 } otuc11RxSapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received sapi(Source Access Point Identifier) " ::= { otuc11Entry 15 } otuc11RxDapi OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received dapi(Destination Access Point Identifier) " ::= { otuc11Entry 16 } otuc11RxOperator OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The received operator TTI " ::= { otuc11Entry 17 } otuc11ManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { otuc11Entry 18 } otuc11DegradeInterval OBJECT-TYPE SYNTAX Unsigned32 (2..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The consecutive number of 1s intervals with the number of detected block errors exceeding the block error threshold for each of those seconds for the purposes of SDBER detection. default value :7" ::= { otuc11Entry 19 } otuc11DegradeThreshold OBJECT-TYPE SYNTAX Unsigned32 (1..2590845) MAX-ACCESS read-only STATUS current DESCRIPTION "The threshold number of block errors at which a 1s interval will be considered degraded for the purposes of SDBER detection. default value :1424967" ::= { otuc11Entry 20 } otuc11Statistics OBJECT IDENTIFIER ::= { otn 65 } otuc11StatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Otuc11StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { otuc11Statistics 1 } otuc11StatisticsEntry OBJECT-TYPE SYNTAX Otuc11StatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otuc11StatisticsTable" INDEX { shelfId,slotId,subslotId,portId } ::= { otuc11StatisticsTable 1 } Otuc11StatisticsEntry ::= SEQUENCE { otuc11StatisticsEntryLastClear IetfYangTypesDateAndTime, otuc11StatisticsEntryLossOfSignalSeconds OCTET STRING, otuc11StatisticsEntryBitErrorFec OCTET STRING, otuc11StatisticsEntryUncorrectedBlockErrorFec OCTET STRING, otuc11StatisticsEntryErroredBlocks OCTET STRING, otuc11StatisticsEntryErroredSeconds OCTET STRING, otuc11StatisticsEntrySeverelyErroredSeconds OCTET STRING, otuc11StatisticsEntryUnavailableSeconds OCTET STRING } otuc11StatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { otuc11StatisticsEntry 1 } otuc11StatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { otuc11StatisticsEntry 2 } otuc11StatisticsEntryBitErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for error bit forward error correction, corresponding to pm parameter BE-FEC UNITS:bits " ::= { otuc11StatisticsEntry 3 } otuc11StatisticsEntryUncorrectedBlockErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics blocks counting for uncorrected block error forward error correction, corresponding to pm parameter UBE-FEC UNITS:blocks " ::= { otuc11StatisticsEntry 4 } otuc11StatisticsEntryErroredBlocks OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for errored blocks, corresponding to pm parameter EB UNITS:blocks " ::= { otuc11StatisticsEntry 5 } otuc11StatisticsEntryErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { otuc11StatisticsEntry 6 } otuc11StatisticsEntrySeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { otuc11StatisticsEntry 7 } otuc11StatisticsEntryUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { otuc11StatisticsEntry 8 } eth1g OBJECT IDENTIFIER ::= { otn 66 } eth1gTable OBJECT-TYPE SYNTAX SEQUENCE OF Eth1gEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { eth1g 1 } eth1gEntry OBJECT-TYPE SYNTAX Eth1gEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of eth1gTable" INDEX { shelfId,slotId,subslotId,portId } ::= { eth1gTable 1 } Eth1gEntry ::= SEQUENCE { eth1gEthFecType CoriantTypesEthFec, eth1gEthFecTypeState CoriantTypesEthFec, eth1gTransmitInterpacketgap Unsigned32, eth1gGfpPayloadFcs CoriantTypesEnableSwitch, eth1gMappingMode INTEGER, eth1gAdminStatus INTEGER, eth1gOperStatus INTEGER, eth1gAvailStatus BITS, eth1gAliasName OCTET STRING, eth1gClientShutdown CoriantTypesYesNo, eth1gClientShutdownHoldoffTimer Unsigned32, eth1gHoldoffSignal CoriantTypesYesNo, eth1gNearEndAls CoriantTypesYesNo, eth1gAlsDegradeMode CoriantTypesEnableSwitch, eth1gLoopbackEnable CoriantTypesEnableSwitch, eth1gLoopbackType INTEGER, eth1gTestSignalType CoriantTypesTestSignalType, eth1gTestSignalEnable CoriantTypesTestSignalConfig, eth1gServiceLabel OCTET STRING, eth1gManagedBy INTEGER, eth1gLldpStatusIf INTEGER, eth1gSpeed Unsigned32, eth1gDuplex INTEGER, eth1gMtu Unsigned32, eth1gAutoNegotiation INTEGER, eth1gCurrSpeed OCTET STRING, eth1gCurrDuplex OCTET STRING } eth1gEthFecType OBJECT-TYPE SYNTAX CoriantTypesEthFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC working type of etyn port. default value :auto" ::= { eth1gEntry 1 } eth1gEthFecTypeState OBJECT-TYPE SYNTAX CoriantTypesEthFec MAX-ACCESS read-only STATUS current DESCRIPTION " The FEC working state of etyn port. default value :disabled" ::= { eth1gEntry 2 } eth1gTransmitInterpacketgap OBJECT-TYPE SYNTAX Unsigned32 (8..12) MAX-ACCESS read-only STATUS current DESCRIPTION " Specifies the minimum transmit IPG value. default value :8" ::= { eth1gEntry 3 } eth1gGfpPayloadFcs OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION " Enabled: GFP payload FCS will be used, Ethernet frame FCS will be removed; Disabled: GFP payload FCS will not be inserted, Ethernet frame FCS will be used. default value :disabled" ::= { eth1gEntry 4 } eth1gMappingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), gmp (1), gfpF (2), t40gbmpOdu2e (3), preamble (4), bmpFixedstuff (5), bmp (6), amp (7), tttGmp (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The mapping mode of client port packets into ODUk. default value :not-applicable" ::= { eth1gEntry 5 } eth1gAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { eth1gEntry 6 } eth1gOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { eth1gEntry 7 } eth1gAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { eth1gEntry 8 } eth1gAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { eth1gEntry 9 } eth1gClientShutdown OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of client-shutdown. default value :no" ::= { eth1gEntry 10 } eth1gClientShutdownHoldoffTimer OBJECT-TYPE SYNTAX Unsigned32 (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The hold off time of client shutdown or replacement siganl at egress direction. UNITS:milliseconds default value :0" ::= { eth1gEntry 11 } eth1gHoldoffSignal OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "Specify if specific signal will be sent out during hold off time which avoid downstream equipment consequent action in the duration. default value :no" ::= { eth1gEntry 12 } eth1gNearEndAls OBJECT-TYPE SYNTAX CoriantTypesYesNo MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of near end ALS. default value :no" ::= { eth1gEntry 13 } eth1gAlsDegradeMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The switching of defect BERSD-ODU trig ALS default value :disabled" ::= { eth1gEntry 14 } eth1gLoopbackEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of loopback function. default value :disabled" ::= { eth1gEntry 15 } eth1gLoopbackType OBJECT-TYPE SYNTAX INTEGER { none (0), terminal (1), facility (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of loopback function default value :none" ::= { eth1gEntry 16 } eth1gTestSignalType OBJECT-TYPE SYNTAX CoriantTypesTestSignalType MAX-ACCESS read-only STATUS current DESCRIPTION "The type mode of test signal. default value :NONE" ::= { eth1gEntry 17 } eth1gTestSignalEnable OBJECT-TYPE SYNTAX CoriantTypesTestSignalConfig MAX-ACCESS read-only STATUS current DESCRIPTION "The enable switching of test signal function default value :NONE" ::= { eth1gEntry 18 } eth1gServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { eth1gEntry 19 } eth1gManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { eth1gEntry 20 } eth1gLldpStatusIf OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), rxonly (2), txandrx (3), disabled (4) } MAX-ACCESS read-only STATUS current DESCRIPTION " Port level lldp control. Value of 'rxonly', then the LLDP agent will receive lldp, when lldp-status-ne is also enabled. Value of 'disabled', then LLDP agent will not filter and receive LLDP frames on this port. If there is remote systems information which is received on this port and stored in the system before the lldp-status becomes disabled, then the information will naturally age out. Note: txOnly and txAndRx modes are not supported in Transponder module. default value :disabled" ::= { eth1gEntry 21 } eth1gSpeed OBJECT-TYPE SYNTAX Unsigned32 (10|100|1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Set speed of the interface, unit mbps. This is for ETH facility. default value :1000" ::= { eth1gEntry 22 } eth1gDuplex OBJECT-TYPE SYNTAX INTEGER { half (0), full (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Set duplex selections. default value :full" ::= { eth1gEntry 23 } eth1gMtu OBJECT-TYPE SYNTAX Unsigned32 (1280..1500) MAX-ACCESS read-only STATUS current DESCRIPTION "Set Maximum Frame Size. default value :1500" ::= { eth1gEntry 24 } eth1gAutoNegotiation OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Set Auto Negotiation: Enabled/Disabled. default value :enabled" ::= { eth1gEntry 25 } eth1gCurrSpeed OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "speed (UNKNOWN/AUTO/10/100/1000/10000) corresponding to the interface " ::= { eth1gEntry 26 } eth1gCurrDuplex OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "duplex (HALF/FULL) corresponding to the interface " ::= { eth1gEntry 27 } eth1gStatistics OBJECT IDENTIFIER ::= { otn 67 } eth1gStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Eth1gStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { eth1gStatistics 1 } eth1gStatisticsEntry OBJECT-TYPE SYNTAX Eth1gStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of eth1gStatisticsTable" INDEX { shelfId,slotId,subslotId,portId } ::= { eth1gStatisticsTable 1 } Eth1gStatisticsEntry ::= SEQUENCE { eth1gStatisticsEntryLastClear IetfYangTypesDateAndTime, eth1gStatisticsEntryLossOfSignalSeconds OCTET STRING, eth1gStatisticsEntryBitErrorFec OCTET STRING, eth1gStatisticsEntryUncorrectedBlockErrorFec OCTET STRING, eth1gStatisticsEntryInSymbolErrors OCTET STRING, eth1gStatisticsEntryInDropEvents OCTET STRING, eth1gStatisticsEntryInOctets OCTET STRING, eth1gStatisticsEntryInPackets OCTET STRING, eth1gStatisticsEntryInBroadcastPackets OCTET STRING, eth1gStatisticsEntryInMulticastPackets OCTET STRING, eth1gStatisticsEntryInCrcAlignErrors OCTET STRING, eth1gStatisticsEntryInUndersizePackets OCTET STRING, eth1gStatisticsEntryInOversizePackets OCTET STRING, eth1gStatisticsEntryInFragments OCTET STRING, eth1gStatisticsEntryInJabbers OCTET STRING, eth1gStatisticsEntryInPackets64octets OCTET STRING, eth1gStatisticsEntryInPackets65to127octets OCTET STRING, eth1gStatisticsEntryInPackets128to255octets OCTET STRING, eth1gStatisticsEntryInPackets256to511octets OCTET STRING, eth1gStatisticsEntryInPackets512to1023octets OCTET STRING, eth1gStatisticsEntryInPackets1024to1518octets OCTET STRING, eth1gStatisticsEntryOutSymbolErrors OCTET STRING, eth1gStatisticsEntryOutDropEvents OCTET STRING, eth1gStatisticsEntryOutOctets OCTET STRING, eth1gStatisticsEntryOutPackets OCTET STRING, eth1gStatisticsEntryOutBroadcastPackets OCTET STRING, eth1gStatisticsEntryOutMulticastPackets OCTET STRING, eth1gStatisticsEntryOutCrcAlignErrors OCTET STRING, eth1gStatisticsEntryOutUndersizePackets OCTET STRING, eth1gStatisticsEntryOutOversizePackets OCTET STRING, eth1gStatisticsEntryOutFragments OCTET STRING, eth1gStatisticsEntryOutJabbers OCTET STRING, eth1gStatisticsEntryOutPackets64octets OCTET STRING, eth1gStatisticsEntryOutPackets65to127octets OCTET STRING, eth1gStatisticsEntryOutPackets128to255octets OCTET STRING, eth1gStatisticsEntryOutPackets256to511octets OCTET STRING, eth1gStatisticsEntryOutPackets512to1023octets OCTET STRING, eth1gStatisticsEntryOutPackets1024to1518octets OCTET STRING, eth1gStatisticsEntryInCodingViolation OCTET STRING, eth1gStatisticsEntryErroredSeconds OCTET STRING, eth1gStatisticsEntrySeverelyErroredSeconds OCTET STRING, eth1gStatisticsEntryUnavailableSeconds OCTET STRING } eth1gStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { eth1gStatisticsEntry 1 } eth1gStatisticsEntryLossOfSignalSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for signal loss, corresponding to pm parameter loss UNITS:seconds " ::= { eth1gStatisticsEntry 2 } eth1gStatisticsEntryBitErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for error bit forward error correction, corresponding to pm parameter BE-FEC UNITS:bits " ::= { eth1gStatisticsEntry 3 } eth1gStatisticsEntryUncorrectedBlockErrorFec OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics blocks counting for uncorrected block error forward error correction, corresponding to pm parameter UBE-FEC UNITS:blocks " ::= { eth1gStatisticsEntry 4 } eth1gStatisticsEntryInSymbolErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics Times counting for input signal symbol errors, corresponding to pm parameter SE UNITS:Events " ::= { eth1gStatisticsEntry 5 } eth1gStatisticsEntryInDropEvents OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input signal drop events, corresponding to pm parameter DropEvents UNITS:events " ::= { eth1gStatisticsEntry 6 } eth1gStatisticsEntryInOctets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input signal octets, corresponding to pm parameter Octets UNITS:octets " ::= { eth1gStatisticsEntry 7 } eth1gStatisticsEntryInPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input signal packets, corresponding to pm parameter Pkts UNITS:packets " ::= { eth1gStatisticsEntry 8 } eth1gStatisticsEntryInBroadcastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input broadcast packets, corresponding to pm parameter BroadcastPkts UNITS:packets " ::= { eth1gStatisticsEntry 9 } eth1gStatisticsEntryInMulticastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input multicast packets, corresponding to pm parameter MulticastPkts UNITS:packets " ::= { eth1gStatisticsEntry 10 } eth1gStatisticsEntryInCrcAlignErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input CRC error packets, corresponding to pm parameter CRCAlignErrors UNITS:packets " ::= { eth1gStatisticsEntry 11 } eth1gStatisticsEntryInUndersizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input undersize packets, corresponding to pm parameter UndersizePkts UNITS:packets " ::= { eth1gStatisticsEntry 12 } eth1gStatisticsEntryInOversizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input oversize packets, corresponding to pm parameter OversizePkts UNITS:packets " ::= { eth1gStatisticsEntry 13 } eth1gStatisticsEntryInFragments OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input fragment packets, corresponding to pm parameter Fragments UNITS:packets " ::= { eth1gStatisticsEntry 14 } eth1gStatisticsEntryInJabbers OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input jabber packets, corresponding to pm parameter Jabbers UNITS:packets " ::= { eth1gStatisticsEntry 15 } eth1gStatisticsEntryInPackets64octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 64 octets packets, corresponding to pm parameter Pkts64Octets UNITS:packets " ::= { eth1gStatisticsEntry 16 } eth1gStatisticsEntryInPackets65to127octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 65 to 127 octets packets, corresponding to pm parameter Pkts65to127Octets UNITS:packets " ::= { eth1gStatisticsEntry 17 } eth1gStatisticsEntryInPackets128to255octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 128 to 255 octets packets, corresponding to pm parameter Pkts128to255Octets UNITS:packets " ::= { eth1gStatisticsEntry 18 } eth1gStatisticsEntryInPackets256to511octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 256 to 511 octets packets, corresponding to pm parameter Pkts256to511Octets UNITS:packets " ::= { eth1gStatisticsEntry 19 } eth1gStatisticsEntryInPackets512to1023octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 512 to 1023 octets packets, corresponding to pm parameter Pkts512to1023Octets UNITS:packets " ::= { eth1gStatisticsEntry 20 } eth1gStatisticsEntryInPackets1024to1518octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for input 1024 to 1518 octets packets, corresponding to pm parameter Pkts1024to1518Octets UNITS:packets " ::= { eth1gStatisticsEntry 21 } eth1gStatisticsEntryOutSymbolErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics Times counting for output signal symbol errors, corresponding to pm parameter SE UNITS:Events " ::= { eth1gStatisticsEntry 22 } eth1gStatisticsEntryOutDropEvents OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output signal drop events, corresponding to pm parameter DropEvents UNITS:events " ::= { eth1gStatisticsEntry 23 } eth1gStatisticsEntryOutOctets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output signal octets, corresponding to pm parameter Octets UNITS:octets " ::= { eth1gStatisticsEntry 24 } eth1gStatisticsEntryOutPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output signal packets, corresponding to pm parameter Pkts UNITS:packets " ::= { eth1gStatisticsEntry 25 } eth1gStatisticsEntryOutBroadcastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output broadcast packets, corresponding to pm parameter BroadcastPkts UNITS:packets " ::= { eth1gStatisticsEntry 26 } eth1gStatisticsEntryOutMulticastPackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output multicast packets, corresponding to pm parameter MulticastPkts UNITS:packets " ::= { eth1gStatisticsEntry 27 } eth1gStatisticsEntryOutCrcAlignErrors OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output CRC error packets, corresponding to pm parameter CRCAlignErrors UNITS:packets " ::= { eth1gStatisticsEntry 28 } eth1gStatisticsEntryOutUndersizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output undersize packets, corresponding to pm parameter UndersizePkts UNITS:packets " ::= { eth1gStatisticsEntry 29 } eth1gStatisticsEntryOutOversizePackets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output oversize packets, corresponding to pm parameter OversizePkts UNITS:packets " ::= { eth1gStatisticsEntry 30 } eth1gStatisticsEntryOutFragments OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output fragment packets, corresponding to pm parameter Fragments UNITS:packets " ::= { eth1gStatisticsEntry 31 } eth1gStatisticsEntryOutJabbers OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output jabber packets, corresponding to pm parameter Jabbers UNITS:packets " ::= { eth1gStatisticsEntry 32 } eth1gStatisticsEntryOutPackets64octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 64 octets packets, corresponding to pm parameter Pkts64Octets UNITS:packets " ::= { eth1gStatisticsEntry 33 } eth1gStatisticsEntryOutPackets65to127octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 65 to 127 octets packets, corresponding to pm parameter Pkts65to127Octets UNITS:packets " ::= { eth1gStatisticsEntry 34 } eth1gStatisticsEntryOutPackets128to255octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 128 to 255 octets packets, corresponding to pm parameter Pkts128to255Octets UNITS:packets " ::= { eth1gStatisticsEntry 35 } eth1gStatisticsEntryOutPackets256to511octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 256 to 511 octets packets, corresponding to pm parameter Pkts256to511Octets UNITS:packets " ::= { eth1gStatisticsEntry 36 } eth1gStatisticsEntryOutPackets512to1023octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 512 to 1023 octets packets, corresponding to pm parameter Pkts512to1023Octets UNITS:packets " ::= { eth1gStatisticsEntry 37 } eth1gStatisticsEntryOutPackets1024to1518octets OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics counting for output 1024 to 1518 octets packets, corresponding to pm parameter Pkts1024to1518Octets UNITS:packets " ::= { eth1gStatisticsEntry 38 } eth1gStatisticsEntryInCodingViolation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics bits counting for ingress coding violation, corresponding to pm parameter CV UNITS:bits " ::= { eth1gStatisticsEntry 39 } eth1gStatisticsEntryErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for errored signal, corresponding to pm parameter ES UNITS:seconds " ::= { eth1gStatisticsEntry 40 } eth1gStatisticsEntrySeverelyErroredSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for severely errored signal, corresponding to pm parameter SES UNITS:seconds " ::= { eth1gStatisticsEntry 41 } eth1gStatisticsEntryUnavailableSeconds OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the statistics seconds counting for unavailable signal, corresponding to pm parameter UAS UNITS:seconds " ::= { eth1gStatisticsEntry 42 } servicesInfo OBJECT IDENTIFIER ::= { services 2 } servicesRoadmTargetPowerMode OBJECT-TYPE SYNTAX INTEGER { psd (1), power (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The optical power control mode of ocrs default value :power" ::= { servicesInfo 1 } cRS OBJECT IDENTIFIER ::= { services 3 } cRSTable OBJECT-TYPE SYNTAX SEQUENCE OF CRSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Cross connection table. " ::= { cRS 1 } cRSEntry OBJECT-TYPE SYNTAX CRSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of cRSTable" INDEX { cRSSrcTp,cRSDstTp } ::= { cRSTable 1 } CRSEntry ::= SEQUENCE { cRSSrcTp RowPointer, cRSDstTp RowPointer, cRSServiceLabel OCTET STRING, cRSManagedBy INTEGER, cRSAliasName OCTET STRING } cRSSrcTp OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION " Source tp of cross connection. " ::= { cRSEntry 1 } cRSDstTp OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION " Destination tp of cross connection. " ::= { cRSEntry 2 } cRSServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection. " ::= { cRSEntry 3 } cRSManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { cRSEntry 4 } cRSAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { cRSEntry 5 } fiberConnection OBJECT IDENTIFIER ::= { services 4 } fiberConnectionTable OBJECT-TYPE SYNTAX SEQUENCE OF FiberConnectionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Fiber connection table which will be user managed and be explicitly provisioned by user. Fiber Connection indicates the physical fiber connection between physical ports or subports. " ::= { fiberConnection 1 } fiberConnectionEntry OBJECT-TYPE SYNTAX FiberConnectionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of fiberConnectionTable" INDEX { fiberConnectionSrcPort,fiberConnectionDstPort } ::= { fiberConnectionTable 1 } FiberConnectionEntry ::= SEQUENCE { fiberConnectionSrcPort RowPointer, fiberConnectionDstPort RowPointer, fiberConnectionType INTEGER, fiberConnectionFiberLabel OCTET STRING, fiberConnectionAliasName OCTET STRING, fiberConnectionFixAttenuationDst CoriantTypesDBPrecision1, fiberConnectionFixAttenuationSrc CoriantTypesDBPrecision1 } fiberConnectionSrcPort OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION " Source port of fiber connection. " ::= { fiberConnectionEntry 1 } fiberConnectionDstPort OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION " Destination port of fiber connection. " ::= { fiberConnectionEntry 2 } fiberConnectionType OBJECT-TYPE SYNTAX INTEGER { twoWay (1), oneWay (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates fiber connection type. default value :two-way" ::= { fiberConnectionEntry 3 } fiberConnectionFiberLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Label of fiber connection. " ::= { fiberConnectionEntry 4 } fiberConnectionAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { fiberConnectionEntry 5 } fiberConnectionFixAttenuationDst OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "external fixed attenuator's attenuation from src-port to dst-port " ::= { fiberConnectionEntry 6 } fiberConnectionFixAttenuationSrc OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "external attenuator's attenuation from dst-port to src-port " ::= { fiberConnectionEntry 7 } optical OBJECT IDENTIFIER ::= { services 5 } ots OBJECT IDENTIFIER ::= { optical 2 } otsTable OBJECT-TYPE SYNTAX SEQUENCE OF OtsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the Optical Transmission Section (OTS) interface entity" ::= { ots 1 } otsEntry OBJECT-TYPE SYNTAX OtsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otsTable" INDEX { otsName } ::= { otsTable 1 } OtsEntry ::= SEQUENCE { otsName CoriantTypesNameIdentifier, otsAdminStatus INTEGER, otsOperStatus INTEGER, otsAvailStatus BITS, otsAliasName OCTET STRING, otsSupportingRxPort OpticalCommonSupportingPort, otsSupportingTxPort OpticalCommonSupportingPort, otsMeasuredSpanLoss CoriantTypesOpticalDB, otsFiberSpectralAttenuationTilt OCTET STRING, otsRamanTiltCoefficient OCTET STRING, otsFiberType INTEGER, otsExternalTxAttenuation CoriantTypesDecimalFract2, otsFiberLengthTx OCTET STRING, otsFiberLengthTxDerived CoriantTypesDecimalFract3, otsSpanDegradeEnable CoriantTypesEnableSwitch, otsSpanDegradeLoss CoriantTypesOpticalDB, otsSpanDegradeHysteresis CoriantTypesOpticalDB, otsSpanLossReceive CoriantTypesDBPrecision3, otsSpanLossTransmit CoriantTypesDBPrecision3, otsIngressSpanLossAgingMargin CoriantTypesDBPrecision3, otsEolMaxLoadPIn CoriantTypesOpticalPowerPrecision2, otsServiceLabel OCTET STRING, otsTargetPowerSetting INTEGER } otsName OBJECT-TYPE SYNTAX CoriantTypesNameIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "The name is defined to uniquely identify the ots optical interface. " ::= { otsEntry 1 } otsAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { otsEntry 2 } otsOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { otsEntry 3 } otsAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { otsEntry 4 } otsAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { otsEntry 5 } otsSupportingRxPort OBJECT-TYPE SYNTAX OpticalCommonSupportingPort MAX-ACCESS read-only STATUS current DESCRIPTION "Supporting Rx port for the optical interface. " ::= { otsEntry 6 } otsSupportingTxPort OBJECT-TYPE SYNTAX OpticalCommonSupportingPort MAX-ACCESS read-only STATUS current DESCRIPTION "Supporting Tx port for the optical interface. " ::= { otsEntry 7 } otsMeasuredSpanLoss OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION "The measured span loss excluding offset. " ::= { otsEntry 8 } otsFiberSpectralAttenuationTilt OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the Fiber Spectral Attenuation Tilt. UNITS:dB default value :unspecified" ::= { otsEntry 9 } otsRamanTiltCoefficient OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the Fiber Spectral Attenuation Tilt. UNITS:dB/W default value :unspecified" ::= { otsEntry 10 } otsFiberType OBJECT-TYPE SYNTAX INTEGER { ssmf (1), leaf (2), twrs (3), twc (4), allwave (5), dsf (6), ls (7), puresilica (8), twreach (9), vistacor (10), teralight (11), drakall (12), twplus (13), twminus (14), pslc (15), oleaf (16), nzDsf (17), ull (18) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicating fiber type of the OTS span. default value :SSMF" ::= { otsEntry 11 } otsExternalTxAttenuation OBJECT-TYPE SYNTAX CoriantTypesDecimalFract2 MAX-ACCESS read-only STATUS current DESCRIPTION "External padding attenuation at transmitting direction. UNITS:dB " ::= { otsEntry 12 } otsFiberLengthTx OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Specify the fiber length of transmitting direction. UNITS:km default value :auto" ::= { otsEntry 13 } otsFiberLengthTxDerived OBJECT-TYPE SYNTAX CoriantTypesDecimalFract3 MAX-ACCESS read-only STATUS current DESCRIPTION "Derived fiber length of transmitting direction. UNITS:km " ::= { otsEntry 14 } otsSpanDegradeEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "switching for span degrade shutdown function default value :disabled" ::= { otsEntry 15 } otsSpanDegradeLoss OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION "The degrade threhsold for recieved span loss default value :28" ::= { otsEntry 16 } otsSpanDegradeHysteresis OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION "The hysteresis of optical revocery threshold of recieved default value :2" ::= { otsEntry 17 } otsSpanLossReceive OBJECT-TYPE SYNTAX CoriantTypesDBPrecision3 MAX-ACCESS read-only STATUS current DESCRIPTION "Span loss on the receiver side. Set by the controller and used by device to set AMP gain. " ::= { otsEntry 20 } otsSpanLossTransmit OBJECT-TYPE SYNTAX CoriantTypesDBPrecision3 MAX-ACCESS read-only STATUS current DESCRIPTION "Span loss on the transmitter side. Set by the controller and used by device to configure MSA compliant channel launch power " ::= { otsEntry 21 } otsIngressSpanLossAgingMargin OBJECT-TYPE SYNTAX CoriantTypesDBPrecision3 MAX-ACCESS read-only STATUS current DESCRIPTION "Span-loss margin used to set optical amplifier gain and output-voa. Day one attenuation of the link, at initial commissioning may increase across wdm link life. span-loss-aging-margin defines the maximum additional loss the wdm link may experience in addition to initial loss without requiring a new design (new amplifier settings). default value :0" ::= { otsEntry 22 } otsEolMaxLoadPIn OBJECT-TYPE SYNTAX CoriantTypesOpticalPowerPrecision2 MAX-ACCESS read-only STATUS current DESCRIPTION "End Of Life Total input power at maximum load used for amplifier control. Calculated during the design, this value shall be used by the amplifier device for the setting so that the reasonable margin is kept to reach this value at the end of life of the wdm link, considering span-loss aging margins are reached " ::= { otsEntry 23 } otsServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { otsEntry 24 } otsTargetPowerSetting OBJECT-TYPE SYNTAX INTEGER { manual (0), auto (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Allows automatic configuration of target values for oxcon. default value :manual" ::= { otsEntry 25 } oms OBJECT IDENTIFIER ::= { optical 3 } omsTable OBJECT-TYPE SYNTAX SEQUENCE OF OmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the optical multiplex section (OMS) interface MO" ::= { oms 1 } omsEntry OBJECT-TYPE SYNTAX OmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of omsTable" INDEX { omsName } ::= { omsTable 1 } OmsEntry ::= SEQUENCE { omsName CoriantTypesNameIdentifier, omsAdminStatus INTEGER, omsOperStatus INTEGER, omsAvailStatus BITS, omsAliasName OCTET STRING, omsSupportingRxPort OpticalCommonSupportingPort, omsSupportingTxPort OpticalCommonSupportingPort, omsParentOtsInterface RowPointer, omsRxOpticalPower OCTET STRING, omsTxOpticalPower OCTET STRING, omsGridMode CoriantTypesGridType, omsInputChannelAttenuationControlMode OpticalCommonAttControlMode, omsOutputChannelAttenuationControlMode OpticalCommonAttControlMode, omsServiceLabel OCTET STRING, omsWorkingMode OpticalCommonChannelWorkingMode } omsName OBJECT-TYPE SYNTAX CoriantTypesNameIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "The name is defined to uniquely identify the oms optical interface. " ::= { omsEntry 1 } omsAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { omsEntry 2 } omsOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { omsEntry 3 } omsAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { omsEntry 4 } omsAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { omsEntry 5 } omsSupportingRxPort OBJECT-TYPE SYNTAX OpticalCommonSupportingPort MAX-ACCESS read-only STATUS current DESCRIPTION "Supporting Rx port for the optical interface. " ::= { omsEntry 6 } omsSupportingTxPort OBJECT-TYPE SYNTAX OpticalCommonSupportingPort MAX-ACCESS read-only STATUS current DESCRIPTION "Supporting Tx port for the optical interface. " ::= { omsEntry 7 } omsParentOtsInterface OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Supporting OTS interface. " ::= { omsEntry 8 } omsRxOpticalPower OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Received optical power default value :not-available" ::= { omsEntry 9 } omsTxOpticalPower OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Transmitted optical power default value :not-available" ::= { omsEntry 10 } omsGridMode OBJECT-TYPE SYNTAX CoriantTypesGridType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates Grid type of the OMS. default value :not-applicable" ::= { omsEntry 11 } omsInputChannelAttenuationControlMode OBJECT-TYPE SYNTAX OpticalCommonAttControlMode MAX-ACCESS read-only STATUS current DESCRIPTION "Specify attenuation control mode of the channel which applicable to all channels of the oms. default value :auto" ::= { omsEntry 13 } omsOutputChannelAttenuationControlMode OBJECT-TYPE SYNTAX OpticalCommonAttControlMode MAX-ACCESS read-only STATUS current DESCRIPTION "Specify attenuation control mode of the channel which applicable to all channels of the oms. default value :auto" ::= { omsEntry 14 } omsServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { omsEntry 15 } omsWorkingMode OBJECT-TYPE SYNTAX OpticalCommonChannelWorkingMode MAX-ACCESS read-only STATUS current DESCRIPTION "The oms working mode for FOADM scenario Conditions:deref(../supporting-rx-port)/../switching-type = 'amplifier' default value :no-monitor" ::= { omsEntry 16 } osc OBJECT IDENTIFIER ::= { optical 4 } oscTable OBJECT-TYPE SYNTAX SEQUENCE OF OscEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the Optical Supervision Channel (OSC) MO" ::= { osc 1 } oscEntry OBJECT-TYPE SYNTAX OscEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of oscTable" INDEX { oscName } ::= { oscTable 1 } OscEntry ::= SEQUENCE { oscName CoriantTypesNameIdentifier, oscAdminStatus INTEGER, oscOperStatus INTEGER, oscAvailStatus BITS, oscAliasName OCTET STRING, oscSupportingRxPort OpticalCommonSupportingPort, oscSupportingTxPort OpticalCommonSupportingPort, oscParentOtsInterface OCTET STRING, oscMode INTEGER, oscWavelength OCTET STRING, oscDataCommunication CoriantTypesEnableSwitch, oscRxOpticalPower OCTET STRING, oscTxOpticalPower OCTET STRING } oscName OBJECT-TYPE SYNTAX CoriantTypesNameIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "The name is defined to uniquely identify the osc optical interface. " ::= { oscEntry 1 } oscAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { oscEntry 2 } oscOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { oscEntry 3 } oscAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { oscEntry 4 } oscAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { oscEntry 5 } oscSupportingRxPort OBJECT-TYPE SYNTAX OpticalCommonSupportingPort MAX-ACCESS read-only STATUS current DESCRIPTION "Supporting Rx port for the optical interface. " ::= { oscEntry 6 } oscSupportingTxPort OBJECT-TYPE SYNTAX OpticalCommonSupportingPort MAX-ACCESS read-only STATUS current DESCRIPTION "Supporting Tx port for the optical interface. " ::= { oscEntry 7 } oscParentOtsInterface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Supporting OTS insterface. default value :unassigned" ::= { oscEntry 8 } oscMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (0), t155m52 (1), t1gbe (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicating the current OSC mode. default value :155M52" ::= { oscEntry 9 } oscWavelength OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the wavelength band of the OSC channel. UNITS:nm default value :1510" ::= { oscEntry 10 } oscDataCommunication OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Configuration for enable or disable data communication network support of the OSC. default value :enabled" ::= { oscEntry 11 } oscRxOpticalPower OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Received optical power default value :not-available" ::= { oscEntry 12 } oscTxOpticalPower OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Transmitted optical power default value :not-available" ::= { oscEntry 13 } gopt OBJECT IDENTIFIER ::= { optical 5 } goptTable OBJECT-TYPE SYNTAX SEQUENCE OF GoptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the Generic Optical Section Interface (GOPT) MO" ::= { gopt 1 } goptEntry OBJECT-TYPE SYNTAX GoptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of goptTable" INDEX { goptName } ::= { goptTable 1 } GoptEntry ::= SEQUENCE { goptName CoriantTypesNameIdentifier, goptAdminStatus INTEGER, goptOperStatus INTEGER, goptAvailStatus BITS, goptAliasName OCTET STRING, goptSupportingRxPort OpticalCommonSupportingPort, goptSupportingTxPort OpticalCommonSupportingPort, goptRxOpticalPower OCTET STRING, goptTxOpticalPower OCTET STRING } goptName OBJECT-TYPE SYNTAX CoriantTypesNameIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "The name is defined to uniquely identify the gopt optical interface. " ::= { goptEntry 1 } goptAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { goptEntry 2 } goptOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { goptEntry 3 } goptAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { goptEntry 4 } goptAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { goptEntry 5 } goptSupportingRxPort OBJECT-TYPE SYNTAX OpticalCommonSupportingPort MAX-ACCESS read-only STATUS current DESCRIPTION "Supporting Rx port for the optical interface. " ::= { goptEntry 6 } goptSupportingTxPort OBJECT-TYPE SYNTAX OpticalCommonSupportingPort MAX-ACCESS read-only STATUS current DESCRIPTION "Supporting Tx port for the optical interface. " ::= { goptEntry 7 } goptRxOpticalPower OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Received optical power default value :not-available" ::= { goptEntry 8 } goptTxOpticalPower OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Transmitted optical power default value :not-available" ::= { goptEntry 9 } omsStatistics OBJECT IDENTIFIER ::= { optical 9 } omsStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF OmsStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { omsStatistics 1 } omsStatisticsEntry OBJECT-TYPE SYNTAX OmsStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of omsStatisticsTable" INDEX { omsName } ::= { omsStatisticsTable 1 } OmsStatisticsEntry ::= SEQUENCE { omsStatisticsEntryLastClear IetfYangTypesDateAndTime } omsStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { omsStatisticsEntry 1 } oscStatistics OBJECT IDENTIFIER ::= { optical 10 } oscStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF OscStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { oscStatistics 1 } oscStatisticsEntry OBJECT-TYPE SYNTAX OscStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of oscStatisticsTable" INDEX { oscName } ::= { oscStatisticsTable 1 } OscStatisticsEntry ::= SEQUENCE { oscStatisticsEntryLastClear IetfYangTypesDateAndTime } oscStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { oscStatisticsEntry 1 } goptStatistics OBJECT IDENTIFIER ::= { optical 11 } goptStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF GoptStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { goptStatistics 1 } goptStatisticsEntry OBJECT-TYPE SYNTAX GoptStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of goptStatisticsTable" INDEX { goptName } ::= { goptStatisticsTable 1 } GoptStatisticsEntry ::= SEQUENCE { goptStatisticsEntryProtectionSwitchDuration OCTET STRING, goptStatisticsEntryProtectionSwitchCount OCTET STRING, goptStatisticsEntryLossTx OCTET STRING, goptStatisticsEntryLossRx OCTET STRING, goptStatisticsEntryLastClear IetfYangTypesDateAndTime } goptStatisticsEntryProtectionSwitchDuration OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Protection Switch Duration, corresponding to pm parameter PSD UNITS:seconds " ::= { goptStatisticsEntry 1 } goptStatisticsEntryProtectionSwitchCount OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Protection Switch Count, corresponding to pm parameter PSC UNITS:times " ::= { goptStatisticsEntry 2 } goptStatisticsEntryLossTx OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of Signal Seconds of Transmit side, corresponding to pm parameter LOSS-TX UNITS:seconds " ::= { goptStatisticsEntry 3 } goptStatisticsEntryLossRx OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of Signal Seconds of Receive side, corresponding to pm parameter LOSS-RX UNITS:seconds " ::= { goptStatisticsEntry 4 } goptStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { goptStatisticsEntry 5 } och OBJECT IDENTIFIER ::= { optical 12 } ochTable OBJECT-TYPE SYNTAX SEQUENCE OF OchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the Optical Channel (OCH) MO" ::= { och 1 } ochEntry OBJECT-TYPE SYNTAX OchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ochTable" INDEX { ochName } ::= { ochTable 1 } OchEntry ::= SEQUENCE { ochName CoriantTypesNameIdentifier, ochAdminStatus INTEGER, ochOperStatus INTEGER, ochAvailStatus BITS, ochAliasName OCTET STRING, ochSupportingRxPort OpticalCommonSupportingPort, ochSupportingTxPort OpticalCommonSupportingPort, ochParentEntity OCTET STRING, ochFrequency Unsigned32, ochWavelength OCTET STRING, ochRxOpticalPower OCTET STRING, ochTxOpticalPower OCTET STRING, ochWorkingMode OpticalCommonChannelWorkingMode } ochName OBJECT-TYPE SYNTAX CoriantTypesNameIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "The name is defined to uniquely identify the och optical interface. " ::= { ochEntry 1 } ochAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { ochEntry 2 } ochOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { ochEntry 3 } ochAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { ochEntry 4 } ochAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { ochEntry 5 } ochSupportingRxPort OBJECT-TYPE SYNTAX OpticalCommonSupportingPort MAX-ACCESS read-only STATUS current DESCRIPTION "Supporting Rx port for the optical interface. " ::= { ochEntry 6 } ochSupportingTxPort OBJECT-TYPE SYNTAX OpticalCommonSupportingPort MAX-ACCESS read-only STATUS current DESCRIPTION "Supporting Tx port for the optical interface. " ::= { ochEntry 7 } ochParentEntity OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Supporting OMS interface. default value :none" ::= { ochEntry 8 } ochFrequency OBJECT-TYPE SYNTAX Unsigned32 (0|191300000..196125000) MAX-ACCESS read-only STATUS current DESCRIPTION "Frequency of the channel with unit MHz. UNITS:MHz " ::= { ochEntry 9 } ochWavelength OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Wavelength of the channel with unit nm. UNITS:nm " ::= { ochEntry 10 } ochRxOpticalPower OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Received optical power default value :not-available" ::= { ochEntry 11 } ochTxOpticalPower OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Transmitted optical power default value :not-available" ::= { ochEntry 12 } ochWorkingMode OBJECT-TYPE SYNTAX OpticalCommonChannelWorkingMode MAX-ACCESS read-only STATUS current DESCRIPTION "och power control function mode Conditions:name(deref(../parent-entity)) = 'oms' default value :no-monitor" ::= { ochEntry 13 } mc OBJECT IDENTIFIER ::= { optical 13 } mcTable OBJECT-TYPE SYNTAX SEQUENCE OF McEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the Media Channel (MC) MO" ::= { mc 1 } mcEntry OBJECT-TYPE SYNTAX McEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of mcTable" INDEX { mcName } ::= { mcTable 1 } McEntry ::= SEQUENCE { mcName CoriantTypesNameIdentifier, mcAdminStatus INTEGER, mcOperStatus INTEGER, mcAvailStatus BITS, mcAliasName OCTET STRING, mcParentEntity RowPointer, mcLowerFrequency Unsigned32, mcUpperFrequency Unsigned32, mcCenterFrequency Unsigned32, mcSlotWidth Unsigned32, mcServiceLabel OCTET STRING } mcName OBJECT-TYPE SYNTAX CoriantTypesNameIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "The name is defined to uniquely identify the mc optical interface. " ::= { mcEntry 1 } mcAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { mcEntry 2 } mcOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { mcEntry 3 } mcAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { mcEntry 4 } mcAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { mcEntry 5 } mcParentEntity OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Specify supporting parent entity. " ::= { mcEntry 6 } mcLowerFrequency OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimal frequency of the mc with unit MHz. UNITS:MHz " ::= { mcEntry 7 } mcUpperFrequency OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max frequency of the mc with unit MHz. UNITS:MHz " ::= { mcEntry 8 } mcCenterFrequency OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Center frequency of the media channel (mc) with unit MHz. UNITS:MHz " ::= { mcEntry 9 } mcSlotWidth OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Slot width of the media channel (mc) with unit MHz. UNITS:MHz " ::= { mcEntry 10 } mcServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { mcEntry 11 } nmc OBJECT IDENTIFIER ::= { optical 14 } nmcTable OBJECT-TYPE SYNTAX SEQUENCE OF NmcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the Network Media Channel (NMC) MO" ::= { nmc 1 } nmcEntry OBJECT-TYPE SYNTAX NmcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of nmcTable" INDEX { nmcName } ::= { nmcTable 1 } NmcEntry ::= SEQUENCE { nmcName CoriantTypesNameIdentifier, nmcAdminStatus INTEGER, nmcOperStatus INTEGER, nmcAvailStatus BITS, nmcAliasName OCTET STRING, nmcParentEntity RowPointer, nmcCenterFrequency Unsigned32, nmcWidth Unsigned32, nmcActualCenterFrequency OCTET STRING, nmcActualWidth OCTET STRING, nmcActualPsd OCTET STRING, nmcRxOpticalPower OCTET STRING, nmcTxOpticalPower OCTET STRING, nmcManagedBy INTEGER, nmcActualOutputPsd CoriantTypesActualPsd, nmcInputPsdMax NmcNmcPsd, nmcInputPsdMin NmcNmcPsd, nmcServiceLabel OCTET STRING, nmcInputPowerMax OCTET STRING, nmcInputPowerMin OCTET STRING } nmcName OBJECT-TYPE SYNTAX CoriantTypesNameIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "The name is defined to uniquely identify the nmc optical interface. " ::= { nmcEntry 1 } nmcAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { nmcEntry 2 } nmcOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { nmcEntry 3 } nmcAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { nmcEntry 4 } nmcAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { nmcEntry 5 } nmcParentEntity OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Specify supporting parent entity. " ::= { nmcEntry 6 } nmcCenterFrequency OBJECT-TYPE SYNTAX Unsigned32 (184600000..196150000) MAX-ACCESS read-only STATUS current DESCRIPTION "Center frequency of the network media channel (nmc) with unit MHz. UNITS:MHz " ::= { nmcEntry 7 } nmcWidth OBJECT-TYPE SYNTAX Unsigned32 (15000..100000) MAX-ACCESS read-only STATUS current DESCRIPTION "Network media channel frequency width with unit MHz. UNITS:MHz " ::= { nmcEntry 8 } nmcActualCenterFrequency OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Actual center frequency of the network media channel (nmc) with unit MHz. default value :not-available" ::= { nmcEntry 9 } nmcActualWidth OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Actual network media channel frequency width with unit MHz. default value :not-available" ::= { nmcEntry 10 } nmcActualPsd OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Actual input power spectral density expressed in nanowatts per megahertz, nW/GHz. default value :not-available" ::= { nmcEntry 11 } nmcRxOpticalPower OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Received optical power default value :not-available" ::= { nmcEntry 12 } nmcTxOpticalPower OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Transmitted optical power default value :not-available" ::= { nmcEntry 13 } nmcManagedBy OBJECT-TYPE SYNTAX INTEGER { system (1), user (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes whether this CRS was system created or not. A system created CRS implies a HW cross connection, that is not manageable by the user. default value :user" ::= { nmcEntry 14 } nmcActualOutputPsd OBJECT-TYPE SYNTAX CoriantTypesActualPsd MAX-ACCESS read-only STATUS current DESCRIPTION "Actual output power spectral density expressed in nanowatts per megahertz, nW/GHz. default value :not-available" ::= { nmcEntry 15 } nmcInputPsdMax OBJECT-TYPE SYNTAX NmcNmcPsd MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum valid input signal psd Conditions:../../../roadm-target-power-mode = 'psd' default value :not-available" ::= { nmcEntry 16 } nmcInputPsdMin OBJECT-TYPE SYNTAX NmcNmcPsd MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum valid input signal psd Conditions:../../../roadm-target-power-mode = 'psd' default value :not-available" ::= { nmcEntry 17 } nmcServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection related facility. default value :" ::= { nmcEntry 18 } nmcInputPowerMax OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum valid input signal power Conditions:../../../roadm-target-power-mode = 'power' default value :not-available" ::= { nmcEntry 19 } nmcInputPowerMin OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum valid input signal power Conditions:../../../roadm-target-power-mode = 'power' default value :not-available" ::= { nmcEntry 20 } nmcInput OBJECT IDENTIFIER ::= { optical 16 } nmcInputTable OBJECT-TYPE SYNTAX SEQUENCE OF NmcInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { nmcInput 1 } nmcInputEntry OBJECT-TYPE SYNTAX NmcInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of nmcInputTable" INDEX { nmcName } ::= { nmcInputTable 1 } NmcInputEntry ::= SEQUENCE { nmcInputInputChannelAttenuationControlMode OpticalCommonAttControlMode, nmcInputActualAttenuation OCTET STRING, nmcInputTargetAttenuation OCTET STRING } nmcInputInputChannelAttenuationControlMode OBJECT-TYPE SYNTAX OpticalCommonAttControlMode MAX-ACCESS read-only STATUS current DESCRIPTION "Specify attenuation control mode of the channel. default value :not-applicable" ::= { nmcInputEntry 1 } nmcInputActualAttenuation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Actually setting attenuation. UNITS:dB default value :not-available" ::= { nmcInputEntry 2 } nmcInputTargetAttenuation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Actually setting attenuation. UNITS:dB default value :max" ::= { nmcInputEntry 3 } nmcOutput OBJECT IDENTIFIER ::= { optical 17 } nmcOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF NmcOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { nmcOutput 1 } nmcOutputEntry OBJECT-TYPE SYNTAX NmcOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of nmcOutputTable" INDEX { nmcName } ::= { nmcOutputTable 1 } NmcOutputEntry ::= SEQUENCE { nmcOutputOutputChannelAttenuationControlMode OpticalCommonAttControlMode, nmcOutputActualAttenuation OCTET STRING, nmcOutputTargetAttenuation OCTET STRING } nmcOutputOutputChannelAttenuationControlMode OBJECT-TYPE SYNTAX OpticalCommonAttControlMode MAX-ACCESS read-only STATUS current DESCRIPTION "Specify attenuation control mode of the channel. default value :not-applicable" ::= { nmcOutputEntry 1 } nmcOutputActualAttenuation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Actually setting attenuation. UNITS:dB default value :not-available" ::= { nmcOutputEntry 2 } nmcOutputTargetAttenuation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Actually setting attenuation. UNITS:dB default value :max" ::= { nmcOutputEntry 3 } nmcStatistics OBJECT IDENTIFIER ::= { optical 18 } nmcStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF NmcStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { nmcStatistics 1 } nmcStatisticsEntry OBJECT-TYPE SYNTAX NmcStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of nmcStatisticsTable" INDEX { nmcName } ::= { nmcStatisticsTable 1 } NmcStatisticsEntry ::= SEQUENCE { nmcStatisticsEntryLossTx OCTET STRING, nmcStatisticsEntryLastClear IetfYangTypesDateAndTime } nmcStatisticsEntryLossTx OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of Signal Seconds of Transmit side, corresponding to pm parameter LOSS-TX UNITS:seconds " ::= { nmcStatisticsEntry 1 } nmcStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { nmcStatisticsEntry 2 } otsStatistics OBJECT IDENTIFIER ::= { optical 19 } otsStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF OtsStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { otsStatistics 1 } otsStatisticsEntry OBJECT-TYPE SYNTAX OtsStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of otsStatisticsTable" INDEX { otsName } ::= { otsStatisticsTable 1 } OtsStatisticsEntry ::= SEQUENCE { otsStatisticsEntryLastClear IetfYangTypesDateAndTime } otsStatisticsEntryLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { otsStatisticsEntry 1 } ochInput OBJECT IDENTIFIER ::= { optical 21 } ochInputTable OBJECT-TYPE SYNTAX SEQUENCE OF OchInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { ochInput 1 } ochInputEntry OBJECT-TYPE SYNTAX OchInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ochInputTable" INDEX { ochName } ::= { ochInputTable 1 } OchInputEntry ::= SEQUENCE { ochInputInputChannelAttenuationControlMode OpticalCommonAttControlMode, ochInputActualAttenuation OCTET STRING, ochInputTargetAttenuation OCTET STRING } ochInputInputChannelAttenuationControlMode OBJECT-TYPE SYNTAX OpticalCommonAttControlMode MAX-ACCESS read-only STATUS current DESCRIPTION "Specify attenuation control mode of the channel. default value :not-applicable" ::= { ochInputEntry 1 } ochInputActualAttenuation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Actually setting attenuation. UNITS:dB default value :not-available" ::= { ochInputEntry 2 } ochInputTargetAttenuation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Actually setting attenuation. UNITS:dB default value :6" ::= { ochInputEntry 3 } ochOutput OBJECT IDENTIFIER ::= { optical 22 } ochOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF OchOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { ochOutput 1 } ochOutputEntry OBJECT-TYPE SYNTAX OchOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ochOutputTable" INDEX { ochName } ::= { ochOutputTable 1 } OchOutputEntry ::= SEQUENCE { ochOutputOutputChannelAttenuationControlMode OpticalCommonAttControlMode, ochOutputActualAttenuation OCTET STRING, ochOutputTargetAttenuation OCTET STRING } ochOutputOutputChannelAttenuationControlMode OBJECT-TYPE SYNTAX OpticalCommonAttControlMode MAX-ACCESS read-only STATUS current DESCRIPTION "Specify attenuation control mode of the channel. default value :not-applicable" ::= { ochOutputEntry 1 } ochOutputActualAttenuation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Actually setting attenuation. UNITS:dB default value :not-available" ::= { ochOutputEntry 2 } ochOutputTargetAttenuation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Actually setting attenuation. UNITS:dB default value :6" ::= { ochOutputEntry 3 } lldp OBJECT IDENTIFIER ::= { services 6 } lldpStatusNe OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION " Global lldp control on NE level. Value of 'enabled', then the LLDP agent will receive, but it will not transmit LLDP frames on all ports with port level lldp not disabled of the NE. Value of 'disabled', then LLDP agent will not filter and receive LLDP frames on all ports of the NE. If there is remote systems information which is received on ports supporting LLDP and stored in the system before the lldp-status becomes disabled, then the information will naturally age out. default value :enabled" ::= { lldp 1 } lldpMsgTxInterval OBJECT-TYPE SYNTAX Unsigned32 (5..32768) MAX-ACCESS read-only STATUS current DESCRIPTION "LLDP frame Retransmit Interval in seconds default value :30" ::= { lldp 2 } lldpMsgTxHoldMultiplier OBJECT-TYPE SYNTAX Unsigned32 (2..10) MAX-ACCESS read-only STATUS current DESCRIPTION "TTL value for the TLVs transmitter over wire in seconds default value :4" ::= { lldp 3 } oCRS OBJECT IDENTIFIER ::= { services 7 } oCRSTable OBJECT-TYPE SYNTAX SEQUENCE OF OCRSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Cross connection table. " ::= { oCRS 1 } oCRSEntry OBJECT-TYPE SYNTAX OCRSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of oCRSTable" INDEX { oCRSSrcIf,oCRSDstIf } ::= { oCRSTable 1 } OCRSEntry ::= SEQUENCE { oCRSSrcIf RowPointer, oCRSDstIf RowPointer, oCRSOpticalConnectionType INTEGER, oCRSTargetPsdDst CoriantTypesDecimalFract2, oCRSTargetPsdSrc CoriantTypesDecimalFract2, oCRSServiceLabel OCTET STRING, oCRSAliasName OCTET STRING, oCRSTargetOutputPowerDst CoriantTypesOpticalPowerPrecision2, oCRSTargetOutputPowerSrc CoriantTypesOpticalPowerPrecision2 } oCRSSrcIf OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION " Source tp of cross connection. " ::= { oCRSEntry 1 } oCRSDstIf OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION " Destination tp of optical cross connection. " ::= { oCRSEntry 2 } oCRSOpticalConnectionType OBJECT-TYPE SYNTAX INTEGER { twoWay (1), oneWay (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the cross connection type. default value :one-way" ::= { oCRSEntry 3 } oCRSTargetPsdDst OBJECT-TYPE SYNTAX CoriantTypesDecimalFract2 MAX-ACCESS read-only STATUS current DESCRIPTION "Destination interface power spectral density expressed in nanowatts per megahertz, nW/GHz. These units allow the value to often be greater than 1.0. It also avoids dealing with zero values for 0dBm. For example, a 40GHz wide channel with 0dBm power would be: 0dBm = 1mW = 10^6nW 0dBm/40GHz = 10^6nW/40GHz = 1000000/40 = 25000 Conditions:../../roadm-target-power-mode = 'psd' UNITS:nW/GHz " ::= { oCRSEntry 4 } oCRSTargetPsdSrc OBJECT-TYPE SYNTAX CoriantTypesDecimalFract2 MAX-ACCESS read-only STATUS current DESCRIPTION "Source interface power spectral density expressed in nanowatts per gigahertz, nW/GHz. These units allow the value to often be greater than 1.0. It also avoids dealing with zero values for 0dBm. For example, a 40GHz wide channel with 0dBm power would be: 0dBm = 1mW = 10^6nW 0dBm/40GHz = 10^6nW/40GHz = 1000000/40 = 25000 Conditions:(../optical-connection-type = 'two-way') and (../../roadm-target-power-mode = 'psd') UNITS:nW/GHz " ::= { oCRSEntry 5 } oCRSServiceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Path/service name of cross-connection. " ::= { oCRSEntry 6 } oCRSAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { oCRSEntry 7 } oCRSTargetOutputPowerDst OBJECT-TYPE SYNTAX CoriantTypesOpticalPowerPrecision2 MAX-ACCESS read-only STATUS current DESCRIPTION "The destination interface target power Conditions:../../roadm-target-power-mode = 'power' " ::= { oCRSEntry 8 } oCRSTargetOutputPowerSrc OBJECT-TYPE SYNTAX CoriantTypesOpticalPowerPrecision2 MAX-ACCESS read-only STATUS current DESCRIPTION "The source interface target power Conditions:../../roadm-target-power-mode = 'power' " ::= { oCRSEntry 9 } internalLink OBJECT IDENTIFIER ::= { services 8 } internalLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF InternalLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { internalLink 1 } internalLinkEntry OBJECT-TYPE SYNTAX InternalLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of internalLinkTable" INDEX { internalLinkName,internalLinkSrcPort,internalLinkDstPort } ::= { internalLinkTable 1 } InternalLinkEntry ::= SEQUENCE { internalLinkName OCTET STRING, internalLinkSrcPort RowPointer, internalLinkDstPort RowPointer } internalLinkName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { internalLinkEntry 1 } internalLinkSrcPort OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { internalLinkEntry 2 } internalLinkDstPort OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { internalLinkEntry 3 } degree OBJECT IDENTIFIER ::= { services 9 } degreeTable OBJECT-TYPE SYNTAX SEQUENCE OF DegreeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { degree 1 } degreeEntry OBJECT-TYPE SYNTAX DegreeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of degreeTable" INDEX { degreeNumber } ::= { degreeTable 1 } DegreeEntry ::= SEQUENCE { degreeNumber Unsigned32, degreeMaxChannels Unsigned32, degreeGroupStatus BITS } degreeNumber OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { degreeEntry 1 } degreeMaxChannels OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "maximum number of DWDM channels " ::= { degreeEntry 2 } degreeGroupStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), moduleMismatch (2), topoFailed (3), topoMismatch (4), notPresent (5), autoLaserShutdown (6), idle (7), busy (8), initializing (9), unknown (10) } MAX-ACCESS read-only STATUS current DESCRIPTION "The group status for ROADM " ::= { degreeEntry 3 } modules OBJECT IDENTIFIER ::= { services 10 } modulesTable OBJECT-TYPE SYNTAX SEQUENCE OF ModulesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "list for Cards associated with a degree" ::= { modules 1 } modulesEntry OBJECT-TYPE SYNTAX ModulesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of modulesTable" INDEX { degreeNumber,sharedRiskGroupSrgNumber,modulesIndex } ::= { modulesTable 1 } ModulesEntry ::= SEQUENCE { modulesIndex Unsigned32, modulesSupportedCard RowPointer } modulesIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { modulesEntry 1 } modulesSupportedCard OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { modulesEntry 2 } connectionPorts OBJECT IDENTIFIER ::= { services 11 } connectionPortsTable OBJECT-TYPE SYNTAX SEQUENCE OF ConnectionPortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port associated with degree: One if bi-directional; two if uni-directional" ::= { connectionPorts 1 } connectionPortsEntry OBJECT-TYPE SYNTAX ConnectionPortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of connectionPortsTable" INDEX { degreeNumber,connectionPortsIndex } ::= { connectionPortsTable 1 } ConnectionPortsEntry ::= SEQUENCE { connectionPortsIndex Unsigned32, connectionPortsSupportedPort RowPointer } connectionPortsIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { connectionPortsEntry 1 } connectionPortsSupportedPort OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { connectionPortsEntry 2 } associatedOtdrPort OBJECT IDENTIFIER ::= { services 12 } associatedOtdrPortTable OBJECT-TYPE SYNTAX SEQUENCE OF AssociatedOtdrPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "otdr port associated with degree." ::= { associatedOtdrPort 1 } associatedOtdrPortEntry OBJECT-TYPE SYNTAX AssociatedOtdrPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of associatedOtdrPortTable" INDEX { degreeNumber } ::= { associatedOtdrPortTable 1 } AssociatedOtdrPortEntry ::= SEQUENCE { associatedOtdrPortSupportedPort RowPointer } associatedOtdrPortSupportedPort OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { associatedOtdrPortEntry 1 } mcCapabilities OBJECT IDENTIFIER ::= { services 13 } mcCapabilitiesTable OBJECT-TYPE SYNTAX SEQUENCE OF McCapabilitiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Capabilities of the media channel on a degree or SRG. This is used to validate mc-ttp provisioning on degrees and SRGs." ::= { mcCapabilities 1 } mcCapabilitiesEntry OBJECT-TYPE SYNTAX McCapabilitiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of mcCapabilitiesTable" INDEX { degreeNumber,sharedRiskGroupSrgNumber } ::= { mcCapabilitiesTable 1 } McCapabilitiesEntry ::= SEQUENCE { mcCapabilitiesSlotWidthGranularity CoriantTypesFreqRoadm, mcCapabilitiesCenterFreqGranularity CoriantTypesFreqRoadm, mcCapabilitiesMinSlots Unsigned32, mcCapabilitiesMaxSlots Unsigned32 } mcCapabilitiesSlotWidthGranularity OBJECT-TYPE SYNTAX CoriantTypesFreqRoadm MAX-ACCESS read-only STATUS current DESCRIPTION "Width of a slot measured in MHz. default value :50000" ::= { mcCapabilitiesEntry 1 } mcCapabilitiesCenterFreqGranularity OBJECT-TYPE SYNTAX CoriantTypesFreqRoadm MAX-ACCESS read-only STATUS current DESCRIPTION "Granularity of allowed center frequencies. The base frequency for this computation is 193100000 MHz (G.694.1) default value :50000" ::= { mcCapabilitiesEntry 2 } mcCapabilitiesMinSlots OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum number of slots permitted to be joined together to form a media channel. Must be less than or equal to the max-slots default value :1" ::= { mcCapabilitiesEntry 3 } mcCapabilitiesMaxSlots OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum number of slots permitted to be joined together to form a media channel. Must be greater than or equal to the min-slots default value :1" ::= { mcCapabilitiesEntry 4 } sharedRiskGroup OBJECT IDENTIFIER ::= { services 14 } sharedRiskGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF SharedRiskGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { sharedRiskGroup 1 } sharedRiskGroupEntry OBJECT-TYPE SYNTAX SharedRiskGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of sharedRiskGroupTable" INDEX { sharedRiskGroupSrgNumber } ::= { sharedRiskGroupTable 1 } SharedRiskGroupEntry ::= SEQUENCE { sharedRiskGroupMaxAddDropPorts Unsigned32, sharedRiskGroupCurrentProvisionedAddDropPorts Unsigned32, sharedRiskGroupSrgNumber Unsigned32, sharedRiskGroupWavelengthDuplication INTEGER, sharedRiskGroupGridCapability INTEGER, sharedRiskGroupGroupStatus BITS } sharedRiskGroupMaxAddDropPorts OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The max number of ports available for a given srg " ::= { sharedRiskGroupEntry 1 } sharedRiskGroupCurrentProvisionedAddDropPorts OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ports currently provisioned for a given srg. " ::= { sharedRiskGroupEntry 2 } sharedRiskGroupSrgNumber OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { sharedRiskGroupEntry 3 } sharedRiskGroupWavelengthDuplication OBJECT-TYPE SYNTAX INTEGER { onePerSrg (1), onePerDegree (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Whether the SRG can handle duplicate wavelengths and if so to what extent. default value :one-per-srg" ::= { sharedRiskGroupEntry 4 } sharedRiskGroupGridCapability OBJECT-TYPE SYNTAX INTEGER { colorless (1), colored (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The srg grid capability selected by request default value :colorless" ::= { sharedRiskGroupEntry 5 } sharedRiskGroupGroupStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), moduleMismatch (2), topoFailed (3), topoMismatch (4), notPresent (5), autoLaserShutdown (6), idle (7), busy (8), initializing (9), unknown (10) } MAX-ACCESS read-only STATUS current DESCRIPTION "The group status for ROADM " ::= { sharedRiskGroupEntry 6 } performance OBJECT IDENTIFIER ::= { groove 5 } performanceInfo OBJECT IDENTIFIER ::= { performance 1 } performancePmdaystart OBJECT-TYPE SYNTAX Unsigned32 (0..23) MAX-ACCESS read-only STATUS current DESCRIPTION " Specifies the hour of starting collecting 1-DAY monitoring parameters. To reset the NE clock to the default value of 00:00 hours, the parameter should contain the value 0. UNITS:hour default value :0" ::= { performanceInfo 1 } performanceStatisticsEnable OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION " The global switch for all system statistics data collection. default value :enabled" ::= { performanceInfo 2 } pmPoint OBJECT IDENTIFIER ::= { performance 2 } pmPointTable OBJECT-TYPE SYNTAX SEQUENCE OF PmPointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The list of performance monitoring points associated with the monitored management object." ::= { pmPoint 1 } pmPointEntry OBJECT-TYPE SYNTAX PmPointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of pmPointTable" INDEX { pmPointPmEntity,pmPointPmpType,pmPointPmTimePeriod } ::= { pmPointTable 1 } PmPointEntry ::= SEQUENCE { pmPointPmEntity CoriantPmtypesPmInstance, pmPointPmpType CoriantPmtypesPmpType, pmPointPmTimePeriod CoriantTypesManagementTimePeriod, pmPointSupervisionSwitch CoriantTypesEnableSwitch, pmPointThresholdingSwitch CoriantTypesEnableSwitch, pmPointHistoryRecording CoriantTypesEnableSwitch } pmPointPmEntity OBJECT-TYPE SYNTAX CoriantPmtypesPmInstance MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the management object instance the performance monitoring data are collected for. " ::= { pmPointEntry 1 } pmPointPmpType OBJECT-TYPE SYNTAX CoriantPmtypesPmpType MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the type of performance monitoring point. " ::= { pmPointEntry 2 } pmPointPmTimePeriod OBJECT-TYPE SYNTAX CoriantTypesManagementTimePeriod MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the time-period increments during which PM data are collected. " ::= { pmPointEntry 3 } pmPointSupervisionSwitch OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Enable/disable counting for all performance monitoring parameters of the given PMP. default value :disabled" ::= { pmPointEntry 4 } pmPointThresholdingSwitch OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Enable/disable the TCA processing and reporting for all performance monitoring parameters of the given PM point. default value :disabled" ::= { pmPointEntry 5 } pmPointHistoryRecording OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Enable/disable the history data storage for all performance monitoring parameters of the given PM point. default value :enabled" ::= { pmPointEntry 6 } pmData OBJECT IDENTIFIER ::= { performance 3 } pmDataCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF PmDataCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the get-pm output of record performance data for current time" ::= { pmData 2 } pmDataCurrentEntry OBJECT-TYPE SYNTAX PmDataCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of pmDataCurrentTable" INDEX { pmPointPmEntity, pmPointPmpType, pmPointPmTimePeriod, pmDataCurrentPmParameter } ::= { pmDataCurrentTable 1 } PmDataCurrentEntry ::= SEQUENCE { pmDataCurrentMonitoringDateTime OCTET STRING, pmDataCurrentPmParameter CoriantPmtypesPmParameter, pmDataCurrentPmValue OCTET STRING, pmDataCurrentPmUnit CoriantCommonpmUnitOfValue, pmDataCurrentValidity CoriantPmtypesValidityType } pmDataCurrentMonitoringDateTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Monitoring data and time' " ::= { pmDataCurrentEntry 1 } pmDataCurrentPmParameter OBJECT-TYPE SYNTAX CoriantPmtypesPmParameter MAX-ACCESS not-accessible STATUS current DESCRIPTION "Performance Monitoring parameter, which could be a counter or gauge parameter, the later support current, max and min values. " ::= { pmDataCurrentEntry 2 } pmDataCurrentPmValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION " PM counter or gauge value of the PM parameter. " ::= { pmDataCurrentEntry 3 } pmDataCurrentPmUnit OBJECT-TYPE SYNTAX CoriantCommonpmUnitOfValue MAX-ACCESS read-only STATUS current DESCRIPTION " Unit of PM value. " ::= { pmDataCurrentEntry 4 } pmDataCurrentValidity OBJECT-TYPE SYNTAX CoriantPmtypesValidityType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether or not a performance monitoring value is valid. " ::= { pmDataCurrentEntry 5 } pmDataLatestHistoryTable OBJECT-TYPE SYNTAX SEQUENCE OF PmDataLatestHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the get-pm output of record performance data for latest history time" ::= { pmData 3 } pmDataLatestHistoryEntry OBJECT-TYPE SYNTAX PmDataLatestHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of pmDataLatestHistoryTable" INDEX { pmPointPmEntity, pmPointPmpType, pmPointPmTimePeriod, pmDataLatestHistoryPmParameter } ::= { pmDataLatestHistoryTable 1 } PmDataLatestHistoryEntry ::= SEQUENCE { pmDataLatestHistoryMonitoringDateTime OCTET STRING, pmDataLatestHistoryPmParameter CoriantPmtypesPmParameter, pmDataLatestHistoryPmValue OCTET STRING, pmDataLatestHistoryPmUnit CoriantCommonpmUnitOfValue, pmDataLatestHistoryValidity CoriantPmtypesValidityType } pmDataLatestHistoryMonitoringDateTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Monitoring data and time' " ::= { pmDataLatestHistoryEntry 1 } pmDataLatestHistoryPmParameter OBJECT-TYPE SYNTAX CoriantPmtypesPmParameter MAX-ACCESS not-accessible STATUS current DESCRIPTION "Performance Monitoring parameter, which could be a counter or gauge parameter, the later support current, max and min values. " ::= { pmDataLatestHistoryEntry 2 } pmDataLatestHistoryPmValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION " PM counter or gauge value of the PM parameter. " ::= { pmDataLatestHistoryEntry 3 } pmDataLatestHistoryPmUnit OBJECT-TYPE SYNTAX CoriantCommonpmUnitOfValue MAX-ACCESS read-only STATUS current DESCRIPTION " Unit of PM value. " ::= { pmDataLatestHistoryEntry 4 } pmDataLatestHistoryValidity OBJECT-TYPE SYNTAX CoriantPmtypesValidityType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether or not a performance monitoring value is valid. " ::= { pmDataLatestHistoryEntry 5 } pmDataHistoryTable OBJECT-TYPE SYNTAX SEQUENCE OF PmDataHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the get-pm output of record performance data for history" ::= { pmData 4 } pmDataHistoryEntry OBJECT-TYPE SYNTAX PmDataHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of pmDataHistoryTable" INDEX { pmPointPmEntity, pmPointPmpType, pmPointPmTimePeriod, pmDataHistoryRecordIndex,pmDataHistoryPmParameter } ::= { pmDataHistoryTable 1 } PmDataHistoryEntry ::= SEQUENCE { pmDataHistoryRecordIndex Unsigned32, pmDataHistoryMonitoringDateTime OCTET STRING, pmDataHistoryPmParameter CoriantPmtypesPmParameter, pmDataHistoryPmValue OCTET STRING, pmDataHistoryPmUnit CoriantCommonpmUnitOfValue, pmDataHistoryValidity CoriantPmtypesValidityType } pmDataHistoryRecordIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of PM data records. " ::= { pmDataHistoryEntry 1 } pmDataHistoryMonitoringDateTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Monitoring data and time' " ::= { pmDataHistoryEntry 2 } pmDataHistoryPmParameter OBJECT-TYPE SYNTAX CoriantPmtypesPmParameter MAX-ACCESS not-accessible STATUS current DESCRIPTION "Performance Monitoring parameter, which could be a counter or gauge parameter, the later support current, max and min values. " ::= { pmDataHistoryEntry 3 } pmDataHistoryPmValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION " PM counter or gauge value of the PM parameter. " ::= { pmDataHistoryEntry 4 } pmDataHistoryPmUnit OBJECT-TYPE SYNTAX CoriantCommonpmUnitOfValue MAX-ACCESS read-only STATUS current DESCRIPTION " Unit of PM value. " ::= { pmDataHistoryEntry 5 } pmDataHistoryValidity OBJECT-TYPE SYNTAX CoriantPmtypesValidityType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether or not a performance monitoring value is valid. " ::= { pmDataHistoryEntry 6 } pmThresholdsValue OBJECT IDENTIFIER ::= { performance 4 } pmThresholdsValueTable OBJECT-TYPE SYNTAX SEQUENCE OF PmThresholdsValueEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The list of entries of performance monitoring threshold value." ::= { pmThresholdsValue 1 } pmThresholdsValueEntry OBJECT-TYPE SYNTAX PmThresholdsValueEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of pmThresholdsValueTable" INDEX { pmPointPmEntity,pmPointPmpType,pmPointPmTimePeriod,pmThresholdsValuePmParameter } ::= { pmThresholdsValueTable 1 } PmThresholdsValueEntry ::= SEQUENCE { pmThresholdsValuePmParameter CoriantPmtypesPmParameter, pmThresholdsValuePmHighThreshold CoriantCommonpmThresholdValue, pmThresholdsValuePmLowThreshold CoriantCommonpmThresholdValue, pmThresholdsValuePmUnit CoriantCommonpmUnitOfValue } pmThresholdsValuePmParameter OBJECT-TYPE SYNTAX CoriantPmtypesPmParameter MAX-ACCESS read-only STATUS current DESCRIPTION "Performance Monitoring parameter, which could be a counter or gauge parameter, the later support current, max and min values. " ::= { pmThresholdsValueEntry 1 } pmThresholdsValuePmHighThreshold OBJECT-TYPE SYNTAX CoriantCommonpmThresholdValue MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the desired high threshold value of the selected performance monitoring parameter. " ::= { pmThresholdsValueEntry 2 } pmThresholdsValuePmLowThreshold OBJECT-TYPE SYNTAX CoriantCommonpmThresholdValue MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the desired low threshold value of the selected performance monitoring parameter. " ::= { pmThresholdsValueEntry 3 } pmThresholdsValuePmUnit OBJECT-TYPE SYNTAX CoriantCommonpmUnitOfValue MAX-ACCESS read-only STATUS current DESCRIPTION "The unit of the performance monitoring value. " ::= { pmThresholdsValueEntry 4 } networking OBJECT IDENTIFIER ::= { groove 6 } networkingInfo OBJECT IDENTIFIER ::= { networking 1 } networkingSourceAddressSelectMode OBJECT-TYPE SYNTAX INTEGER { loopbackPrefer (1), linkPrefer (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Select the source address for route next-hop entry. default value :link-prefer" ::= { networkingInfo 1 } networkingReservedSubnet OBJECT-TYPE SYNTAX IetfInetTypesIpv4Prefix MAX-ACCESS read-only STATUS current DESCRIPTION "reserved subnet for internal use, prefix-length should be 24. default value :192.168.199.0/24" ::= { networkingInfo 2 } interface OBJECT IDENTIFIER ::= { networking 2 } interfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF InterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The list of configured interfaces on the device." ::= { interface 1 } interfaceEntry OBJECT-TYPE SYNTAX InterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of interfaceTable" INDEX { interfaceIfName } ::= { interfaceTable 1 } InterfaceEntry ::= SEQUENCE { interfaceIfName OCTET STRING, interfaceIfDescription OCTET STRING, interfaceIfType INTEGER, interfaceAdminStatus INTEGER, interfaceOperStatus INTEGER, interfaceAvailStatus BITS, interfaceAliasName OCTET STRING } interfaceIfName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the interface. " ::= { interfaceEntry 1 } interfaceIfDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of the interface. " ::= { interfaceEntry 2 } interfaceIfType OBJECT-TYPE SYNTAX INTEGER { other (0), ethernetcsmacd (1), ppp (2), softwareloopback (3), lapd (4), oscx (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the interface. Refer to http://www.iana.org/assignments/smi-numbers " ::= { interfaceEntry 3 } interfaceAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { interfaceEntry 4 } interfaceOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :down" ::= { interfaceEntry 5 } interfaceAvailStatus OBJECT-TYPE SYNTAX BITS { none (0), failed (1), mismatch (2), lowerLayerDown (3), notPresent (4), shutdown (5), degraded (6), idle (7), busy (8), hibernation (9), inTest (10), loopback (11), softwareUpgrade (12), initializing (13), unknown (14), incomplete (15), laserSafetyShutoff (16), measuring (17), firmwareLoading (18), connected (19), communicationFailed (20) } MAX-ACCESS read-only STATUS current DESCRIPTION " Provided to qualify the operational, usage and/or administrative status attributes. The value shall be a bits, management interface shall show the string with space separator ' ' per yang definition. Following available status indication shall be supported: Failed,Mismatch,LowerLayerDown,NotPresent,Shutdown,Degraded,Idle,Busy, Hibernation,In-Test,Loopback,SoftwareUpgrade,Initializing,Unknown,Incomplete Example: an ODU can be failed without cross connection, the available status is 'Failed Idle'. Provided to qualify the operational, usage and/or administrative state attributes. The value of each status attribute may denote the presence of one or more particular conditions applicable to the resource. " ::= { interfaceEntry 6 } interfaceAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { interfaceEntry 7 } ethernet OBJECT IDENTIFIER ::= { networking 3 } ethernetTable OBJECT-TYPE SYNTAX SEQUENCE OF EthernetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Ethernet attributes of an Ethernet interface." ::= { ethernet 1 } ethernetEntry OBJECT-TYPE SYNTAX EthernetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ethernetTable" INDEX { interfaceIfName } ::= { ethernetTable 1 } EthernetEntry ::= SEQUENCE { ethernetAutoNegotiation CoriantTypesEnableSwitch, ethernetDuplexMode CoriantTypesDuplexMode, ethernetOperationalDuplexMode CoriantTypesDuplexMode, ethernetRate CoriantTypesEthernetRate, ethernetOperationalEthernetRate CoriantTypesEthernetRate, ethernetFlowControl CoriantTypesFlowControl, ethernetOperationalFlowControl CoriantTypesFlowControl, ethernetMacAddress IetfYangTypesMacAddress, ethernetAliasName OCTET STRING, ethernetEthResourceRef RowPointer } ethernetAutoNegotiation OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Auto negotiation mode. default value :enabled" ::= { ethernetEntry 1 } ethernetDuplexMode OBJECT-TYPE SYNTAX CoriantTypesDuplexMode MAX-ACCESS read-only STATUS current DESCRIPTION "Duplex Mode; only valid if auto negotiation is disabled. default value :full" ::= { ethernetEntry 2 } ethernetOperationalDuplexMode OBJECT-TYPE SYNTAX CoriantTypesDuplexMode MAX-ACCESS read-only STATUS current DESCRIPTION "Operational duplex mode. default value :NA" ::= { ethernetEntry 3 } ethernetRate OBJECT-TYPE SYNTAX CoriantTypesEthernetRate MAX-ACCESS read-only STATUS current DESCRIPTION "Required Ethernet Rate; only valid if auto negotiation is disabled. default value :max-rate" ::= { ethernetEntry 4 } ethernetOperationalEthernetRate OBJECT-TYPE SYNTAX CoriantTypesEthernetRate MAX-ACCESS read-only STATUS current DESCRIPTION "Operation ethernet rate. default value :NA" ::= { ethernetEntry 5 } ethernetFlowControl OBJECT-TYPE SYNTAX CoriantTypesFlowControl MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the type of flow control to be supported. default value :tx-rx" ::= { ethernetEntry 6 } ethernetOperationalFlowControl OBJECT-TYPE SYNTAX CoriantTypesFlowControl MAX-ACCESS read-only STATUS current DESCRIPTION "Operational flow control. default value :NA" ::= { ethernetEntry 7 } ethernetMacAddress OBJECT-TYPE SYNTAX IetfYangTypesMacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "MAC Address of the port. default value :00:00:00:00:00:00" ::= { ethernetEntry 8 } ethernetAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { ethernetEntry 9 } ethernetEthResourceRef OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Reference of the lower layer resource associated with this interface. " ::= { ethernetEntry 10 } ppp OBJECT IDENTIFIER ::= { networking 4 } pppTable OBJECT-TYPE SYNTAX SEQUENCE OF PppEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { ppp 1 } pppEntry OBJECT-TYPE SYNTAX PppEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of pppTable" INDEX { interfaceIfName } ::= { pppTable 1 } PppEntry ::= SEQUENCE { pppType INTEGER, pppPfRef RowPointer, pppResourceRef RowPointer, pppAliasName OCTET STRING, pppPeerIpAddress IetfInetTypesIpv4AddressNoZone } pppType OBJECT-TYPE SYNTAX INTEGER { gcc0 (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the link type associated with the ppp. " ::= { pppEntry 1 } pppPfRef OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Reference of the ppp profile. " ::= { pppEntry 2 } pppResourceRef OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Reference of the lower layer resource associated with this interface. " ::= { pppEntry 3 } pppAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { pppEntry 4 } pppPeerIpAddress OBJECT-TYPE SYNTAX IetfInetTypesIpv4AddressNoZone MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address on the peer node. default value :0.0.0.0" ::= { pppEntry 5 } ipv4 OBJECT IDENTIFIER ::= { networking 5 } ipv4Table OBJECT-TYPE SYNTAX SEQUENCE OF Ipv4Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Parameters for the IPv4 address family." ::= { ipv4 1 } ipv4Entry OBJECT-TYPE SYNTAX Ipv4Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ipv4Table" INDEX { interfaceIfName } ::= { ipv4Table 1 } Ipv4Entry ::= SEQUENCE { ipv4Forwarding TruthValue, ipv4Mtu Unsigned32, ipv4AddressAssignmentMethod INTEGER, ipv4ProxyArp TruthValue } ipv4Forwarding OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Controls IPv4 packet forwarding of datagrams received by, but not addressed to, this interface. IPv4 routers forward datagrams. IPv4 hosts do not (except those source-routed via the host). default value :true" ::= { ipv4Entry 1 } ipv4Mtu OBJECT-TYPE SYNTAX Unsigned32 (68..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The size, in octets, of the largest IPv4 packet that the interface will send and receive. The server may restrict the allowed values for this leaf, depending on the interface's type. All interfaces except LOOPBACK range 68..1500, octets. If this leaf is not configured, the operationally used MTU depends on the interface's type. UNITS:octets default value :1500" ::= { ipv4Entry 2 } ipv4AddressAssignmentMethod OBJECT-TYPE SYNTAX INTEGER { static (1), dhcp (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "IPv4 address assignment method. default value :static" ::= { ipv4Entry 3 } ipv4ProxyArp OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Proxy ARP switch on an ethernetCsmacd interface. Conditions:../../if-type = 'ethernetCsmacd' default value :false" ::= { ipv4Entry 4 } ipAddress OBJECT IDENTIFIER ::= { networking 6 } ipAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF IpAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IP address on the interface." ::= { ipAddress 1 } ipAddressEntry OBJECT-TYPE SYNTAX IpAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ipAddressTable" INDEX { interfaceIfName } ::= { ipAddressTable 1 } IpAddressEntry ::= SEQUENCE { ipAddressIp IetfInetTypesIpv4AddressNoZone, ipAddressOrigin INTEGER, ipAddressPrefixLength Unsigned32 } ipAddressIp OBJECT-TYPE SYNTAX IetfInetTypesIpv4AddressNoZone MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address on the interface. " ::= { ipAddressEntry 1 } ipAddressOrigin OBJECT-TYPE SYNTAX INTEGER { other (1), static (2), dhcp (3), linkLayer (4), random (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The origin of this address. default value :static" ::= { ipAddressEntry 2 } ipAddressPrefixLength OBJECT-TYPE SYNTAX Unsigned32 (0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The length of the subnet prefix. " ::= { ipAddressEntry 3 } ipUnnumbered OBJECT IDENTIFIER ::= { networking 7 } ipUnnumberedTable OBJECT-TYPE SYNTAX SEQUENCE OF IpUnnumberedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IP unnumbered configurations." ::= { ipUnnumbered 1 } ipUnnumberedEntry OBJECT-TYPE SYNTAX IpUnnumberedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ipUnnumberedTable" INDEX { interfaceIfName } ::= { ipUnnumberedTable 1 } IpUnnumberedEntry ::= SEQUENCE { ipUnnumberedUnnumEnabled TruthValue, ipUnnumberedParentInterface RowPointer } ipUnnumberedUnnumEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates that the interface is unnumbered. By default the interface is numbered, i.e., expected to have an IP address configuration. default value :false" ::= { ipUnnumberedEntry 1 } ipUnnumberedParentInterface OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Reference of the parent interface of the unnumbered interface. " ::= { ipUnnumberedEntry 2 } routingProtocol OBJECT IDENTIFIER ::= { networking 9 } routingProtocolTable OBJECT-TYPE SYNTAX SEQUENCE OF RoutingProtocolEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Routing protocol instance." ::= { routingProtocol 1 } routingProtocolEntry OBJECT-TYPE SYNTAX RoutingProtocolEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of routingProtocolTable" INDEX { routingProtocolRtpType,routingProtocolRtpName } ::= { routingProtocolTable 1 } RoutingProtocolEntry ::= SEQUENCE { routingProtocolRtpType CoriantTypesRtpType, routingProtocolRtpName OCTET STRING, routingProtocolDescription OCTET STRING } routingProtocolRtpType OBJECT-TYPE SYNTAX CoriantTypesRtpType MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the routing protocol instance. " ::= { routingProtocolEntry 1 } routingProtocolRtpName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the routing protocol instance. For system-controlled instances this name is persistent, i.e., it SHOULD NOT change across reboots. " ::= { routingProtocolEntry 2 } routingProtocolDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of the routing protocol instance. " ::= { routingProtocolEntry 3 } staticRoute OBJECT IDENTIFIER ::= { networking 10 } staticRouteTable OBJECT-TYPE SYNTAX SEQUENCE OF StaticRouteEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of static routes." ::= { staticRoute 1 } staticRouteEntry OBJECT-TYPE SYNTAX StaticRouteEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of staticRouteTable" INDEX { routingProtocolRtpType,routingProtocolRtpName,staticRouteDestinationPrefix } ::= { staticRouteTable 1 } StaticRouteEntry ::= SEQUENCE { staticRouteDestinationPrefix IetfInetTypesIpPrefix, staticRouteDescription OCTET STRING, staticRouteAdvertised TruthValue } staticRouteDestinationPrefix OBJECT-TYPE SYNTAX IetfInetTypesIpPrefix (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "IP destination prefix. " ::= { staticRouteEntry 1 } staticRouteDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of the static route. " ::= { staticRouteEntry 2 } staticRouteAdvertised OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "When set to YES, the static route is advertised in the routing protocol. For OSPF, the static route will be advertised as an AS external route, if OSPF is configured as an ASBR. default value :false" ::= { staticRouteEntry 3 } ospf OBJECT IDENTIFIER ::= { networking 12 } ospfTable OBJECT-TYPE SYNTAX SEQUENCE OF OspfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "OSPF protocol." ::= { ospf 1 } ospfEntry OBJECT-TYPE SYNTAX OspfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ospfTable" INDEX { routingProtocolRtpType,routingProtocolRtpName } ::= { ospfTable 1 } OspfEntry ::= SEQUENCE { ospfRouterId IetfYangTypesDottedQuad, ospfDescription OCTET STRING, ospfAsbr TruthValue, ospfAdminStatus INTEGER, ospfOperStatus INTEGER, ospfAliasName OCTET STRING } ospfRouterId OBJECT-TYPE SYNTAX IetfYangTypesDottedQuad MAX-ACCESS read-only STATUS current DESCRIPTION "OSPF Router ID. " ::= { ospfEntry 1 } ospfDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of the OSPF instance. " ::= { ospfEntry 2 } ospfAsbr OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "OSPF Autonomous System Boundary Router. default value :true" ::= { ospfEntry 3 } ospfAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :down" ::= { ospfEntry 4 } ospfOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { ospfEntry 5 } ospfAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { ospfEntry 6 } ospfArea OBJECT IDENTIFIER ::= { networking 13 } ospfAreaTable OBJECT-TYPE SYNTAX SEQUENCE OF OspfAreaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration of ospf area." ::= { ospfArea 1 } ospfAreaEntry OBJECT-TYPE SYNTAX OspfAreaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ospfAreaTable" INDEX { routingProtocolRtpType,routingProtocolRtpName,ospfAreaId } ::= { ospfAreaTable 1 } OspfAreaEntry ::= SEQUENCE { ospfAreaId IetfYangTypesDottedQuad, ospfAreaAdminStatus INTEGER, ospfAreaOperStatus INTEGER, ospfAreaAliasName OCTET STRING, ospfAreaType INTEGER } ospfAreaId OBJECT-TYPE SYNTAX IetfYangTypesDottedQuad (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "OSPF Router Area ID. " ::= { ospfAreaEntry 1 } ospfAreaAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { ospfAreaEntry 2 } ospfAreaOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { ospfAreaEntry 3 } ospfAreaAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { ospfAreaEntry 4 } ospfAreaType OBJECT-TYPE SYNTAX INTEGER { normal (1), stub (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "OSPF Router Area Type. default value :normal" ::= { ospfAreaEntry 5 } ospfInterface OBJECT IDENTIFIER ::= { networking 14 } ospfInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF OspfInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration of interface in an ospf area." ::= { ospfInterface 1 } ospfInterfaceEntry OBJECT-TYPE SYNTAX OspfInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ospfInterfaceTable" INDEX { routingProtocolRtpType,routingProtocolRtpName,ospfAreaId,ospfInterfaceOspfIfName } ::= { ospfInterfaceTable 1 } OspfInterfaceEntry ::= SEQUENCE { ospfInterfaceOspfIfName OCTET STRING, ospfInterfaceOspfLinkpf OCTET STRING, ospfInterfaceOspfCost Unsigned32, ospfInterfaceOspfIfRouting INTEGER, ospfInterfaceOspfNetworkType INTEGER, ospfInterfaceDrPriority Unsigned32 } ospfInterfaceOspfIfName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Reference of the interface in OSPF area. " ::= { ospfInterfaceEntry 1 } ospfInterfaceOspfLinkpf OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Reference of the ospf link profile associated with the interface. " ::= { ospfInterfaceEntry 2 } ospfInterfaceOspfCost OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "OSPF link cost. " ::= { ospfInterfaceEntry 3 } ospfInterfaceOspfIfRouting OBJECT-TYPE SYNTAX INTEGER { active (1), passive (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies if Routing is enabled and if so, if Routing is passive or active. ACTIVE - This link is advertised and routing messages are transported over this link. PASSIVE - This link is advertised, routing messages are not transported over this link. default value :active" ::= { ospfInterfaceEntry 4 } ospfInterfaceOspfNetworkType OBJECT-TYPE SYNTAX INTEGER { broadcast (1), pointToPoint (2), pointToMultipoint (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "OSPF Interface Network Types. " ::= { ospfInterfaceEntry 5 } ospfInterfaceDrPriority OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The local system's priority to become the designated router default value :1" ::= { ospfInterfaceEntry 6 } ospfAdjacency OBJECT IDENTIFIER ::= { networking 15 } ospfAdjacencyTable OBJECT-TYPE SYNTAX SEQUENCE OF OspfAdjacencyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "attributes of OSPF adjacency." ::= { ospfAdjacency 1 } ospfAdjacencyEntry OBJECT-TYPE SYNTAX OspfAdjacencyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ospfAdjacencyTable" INDEX { routingProtocolRtpType,routingProtocolRtpName,ospfAreaId,ospfInterfaceOspfIfName,ospfAdjacencyOspfNeighborAddress } ::= { ospfAdjacencyTable 1 } OspfAdjacencyEntry ::= SEQUENCE { ospfAdjacencyOspfNeighborAddress IetfInetTypesIpv4Address, ospfAdjacencyNeighborRouterId IetfYangTypesDottedQuad, ospfAdjacencyOspfAdjStatus INTEGER } ospfAdjacencyOspfNeighborAddress OBJECT-TYPE SYNTAX IetfInetTypesIpv4Address (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "neighbor IP address of the OSPF adjacency. " ::= { ospfAdjacencyEntry 1 } ospfAdjacencyNeighborRouterId OBJECT-TYPE SYNTAX IetfYangTypesDottedQuad MAX-ACCESS read-only STATUS current DESCRIPTION "OSPF neighbor Router ID. " ::= { ospfAdjacencyEntry 2 } ospfAdjacencyOspfAdjStatus OBJECT-TYPE SYNTAX INTEGER { down (1), init (2), attempt (3), twoWay (4), exstart (5), exchange (6), loading (7), full (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "OSPF adjacency status. " ::= { ospfAdjacencyEntry 3 } rib OBJECT IDENTIFIER ::= { networking 16 } ribTable OBJECT-TYPE SYNTAX SEQUENCE OF RibEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry represents a RIB identified by the 'name' key. All routes in a RIB MUST belong to the same address family. For each routing instance, an implementation SHOULD provide one system-controlled default RIB for each supported address family." ::= { rib 1 } ribEntry OBJECT-TYPE SYNTAX RibEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ribTable" INDEX { ribName } ::= { ribTable 1 } RibEntry ::= SEQUENCE { ribName OCTET STRING, ribAddressFamily INTEGER, ribDefaultRib TruthValue, ribDescription OCTET STRING } ribName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the RIB. " ::= { ribEntry 1 } ribAddressFamily OBJECT-TYPE SYNTAX INTEGER { ipv4 (1), ipv4Unicast (2), ipv6 (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Address family. " ::= { ribEntry 2 } ribDefaultRib OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This flag has the value of 'true' if and only if the RIB is the default RIB for the given address family. A default RIB always receives direct routes. By default it also receives routes from all routing protocols. default value :true" ::= { ribEntry 3 } ribDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of the RIB. " ::= { ribEntry 4 } route OBJECT IDENTIFIER ::= { networking 17 } routeTable OBJECT-TYPE SYNTAX SEQUENCE OF RouteEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of static routes." ::= { route 1 } routeEntry OBJECT-TYPE SYNTAX RouteEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of routeTable" INDEX { ribName,routeSourceProtocol,routeDestinationPrefix } ::= { routeTable 1 } RouteEntry ::= SEQUENCE { routeSourceProtocol CoriantTypesSourceProtocol, routeDestinationPrefix IetfInetTypesIpPrefix, routeDescription OCTET STRING, routePreference Unsigned32, routeActive TruthValue } routeSourceProtocol OBJECT-TYPE SYNTAX CoriantTypesSourceProtocol MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the routing protocol from which the route originated. " ::= { routeEntry 1 } routeDestinationPrefix OBJECT-TYPE SYNTAX IetfInetTypesIpPrefix (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "IP destination prefix. " ::= { routeEntry 2 } routeDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of the route. " ::= { routeEntry 3 } routePreference OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This route attribute, also known as administrative distance, allows for selecting the preferred route among routes with the same destination prefix. A smaller value means a more preferred route. " ::= { routeEntry 4 } routeActive OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates that the route is preferred among all routes in the same RIB that have the same destination prefix. " ::= { routeEntry 5 } profiles OBJECT IDENTIFIER ::= { networking 18 } pppProfile OBJECT IDENTIFIER ::= { profiles 1 } pppProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF PppProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Profile for the point-to-point interface." ::= { pppProfile 1 } pppProfileEntry OBJECT-TYPE SYNTAX PppProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of pppProfileTable" INDEX { pppProfilePppPfName } ::= { pppProfileTable 1 } PppProfileEntry ::= SEQUENCE { pppProfilePppPfName OCTET STRING, pppProfilePppFcsLength INTEGER, pppProfilePppMru Unsigned32, pppProfilePppRestartTimer Unsigned32, pppProfilePppMaxFailure Unsigned32 } pppProfilePppPfName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the point-to-point protocol profile. " ::= { pppProfileEntry 1 } pppProfilePppFcsLength OBJECT-TYPE SYNTAX INTEGER { t16 (16), t32 (32) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies whether the frame check sequence is a 16-bit or 32-bit value. default value :16" ::= { pppProfileEntry 2 } pppProfilePppMru OBJECT-TYPE SYNTAX Unsigned32 (64..1500) MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the maximum number of octets in the Information and Padding fields. UNITS:octets default value :1500" ::= { pppProfileEntry 3 } pppProfilePppRestartTimer OBJECT-TYPE SYNTAX Unsigned32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the restart timer of the PPP protocol in seconds. UNITS:seconds default value :3" ::= { pppProfileEntry 4 } pppProfilePppMaxFailure OBJECT-TYPE SYNTAX Unsigned32 (2..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the maximum failure value of the PPP protocol profile. default value :5" ::= { pppProfileEntry 5 } ospfLinkProfile OBJECT IDENTIFIER ::= { profiles 2 } ospfLinkProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF OspfLinkProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Profile for the OSPF protocol link." ::= { ospfLinkProfile 1 } ospfLinkProfileEntry OBJECT-TYPE SYNTAX OspfLinkProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ospfLinkProfileTable" INDEX { ospfLinkProfileOspfLinkpfName } ::= { ospfLinkProfileTable 1 } OspfLinkProfileEntry ::= SEQUENCE { ospfLinkProfileOspfLinkpfName OCTET STRING, ospfLinkProfileHelloInterval Unsigned32, ospfLinkProfileRouterDeadInterval Unsigned32, ospfLinkProfileRetransmissionInterval Unsigned32 } ospfLinkProfileOspfLinkpfName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the OSPF protocol link profile. " ::= { ospfLinkProfileEntry 1 } ospfLinkProfileHelloInterval OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the Hello Interval in seconds. UNITS:seconds default value :10" ::= { ospfLinkProfileEntry 2 } ospfLinkProfileRouterDeadInterval OBJECT-TYPE SYNTAX Unsigned32 (4..1024) MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the Router Dead Interval in seconds. UNITS:seconds default value :40" ::= { ospfLinkProfileEntry 3 } ospfLinkProfileRetransmissionInterval OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the Retransmission Interval in seconds. UNITS:seconds default value :5" ::= { ospfLinkProfileEntry 4 } oscx OBJECT IDENTIFIER ::= { networking 19 } oscxTable OBJECT-TYPE SYNTAX SEQUENCE OF OscxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "OSCX (Optical Supervisory Channel Extended) interface" ::= { oscx 1 } oscxEntry OBJECT-TYPE SYNTAX OscxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of oscxTable" INDEX { interfaceIfName } ::= { oscxTable 1 } OscxEntry ::= SEQUENCE { oscxChannel INTEGER, oscxResourceRef RowPointer, oscxAliasName OCTET STRING } oscxChannel OBJECT-TYPE SYNTAX INTEGER { t1 (1), t2 (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the OSCX channel within the Optical Supervisory Channel. " ::= { oscxEntry 1 } oscxResourceRef OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Reference of the lower layer resource associated with this interface. " ::= { oscxEntry 2 } oscxAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { oscxEntry 3 } ipv6 OBJECT IDENTIFIER ::= { networking 20 } ipv6Table OBJECT-TYPE SYNTAX SEQUENCE OF Ipv6Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Parameters for the IPv6 address family." ::= { ipv6 1 } ipv6Entry OBJECT-TYPE SYNTAX Ipv6Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ipv6Table" INDEX { interfaceIfName } ::= { ipv6Table 1 } Ipv6Entry ::= SEQUENCE { ipv6Enabled TruthValue, ipv6Forwarding TruthValue, ipv6Mtu Unsigned32, ipv6AddressAssignmentMethod INTEGER } ipv6Enabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Controls whether IPv6 is enabled or disabled on this interface. When IPv6 is enabled, this interface is connected to an IPv6 stack, and the interface can send and receive IPv6 packets. default value :false" ::= { ipv6Entry 1 } ipv6Forwarding OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Controls IPv6 packet forwarding of datagrams received by, but not addressed to, this interface. IPv6 routers forward datagrams. IPv6 hosts do not (except those source-routed via the host). default value :false" ::= { ipv6Entry 2 } ipv6Mtu OBJECT-TYPE SYNTAX Unsigned32 (1280..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "The size, in octets, of the largest IPv6 packet that the interface will send and receive. The server may restrict the allowed values for this leaf, depending on the interface's type. If this leaf is not configured, the operationally used MTU depends on the interface's type. UNITS:octets default value :1500" ::= { ipv6Entry 3 } ipv6AddressAssignmentMethod OBJECT-TYPE SYNTAX INTEGER { static (1), autoconfig (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "IPv6 address assignment method. default value :autoconfig" ::= { ipv6Entry 4 } ipv6Address OBJECT IDENTIFIER ::= { networking 21 } ipv6AddressTable OBJECT-TYPE SYNTAX SEQUENCE OF Ipv6AddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IP address on the interface. index=1 ipv6 address, index=2 ipv6 link-local address, read-only" ::= { ipv6Address 1 } ipv6AddressEntry OBJECT-TYPE SYNTAX Ipv6AddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ipv6AddressTable" INDEX { interfaceIfName,ipv6AddressIndex } ::= { ipv6AddressTable 1 } Ipv6AddressEntry ::= SEQUENCE { ipv6AddressIndex Unsigned32, ipv6AddressIp IetfInetTypesIpv6AddressNoZone, ipv6AddressOrigin INTEGER, ipv6AddressPrefixLength Unsigned32 } ipv6AddressIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "an uint16 index. " ::= { ipv6AddressEntry 1 } ipv6AddressIp OBJECT-TYPE SYNTAX IetfInetTypesIpv6AddressNoZone MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address on the interface. " ::= { ipv6AddressEntry 2 } ipv6AddressOrigin OBJECT-TYPE SYNTAX INTEGER { other (1), static (2), dhcp (3), linkLayer (4), random (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The origin of this address. default value :static" ::= { ipv6AddressEntry 3 } ipv6AddressPrefixLength OBJECT-TYPE SYNTAX Unsigned32 (0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The length of the subnet prefix. " ::= { ipv6AddressEntry 4 } staticRouteNextHop OBJECT IDENTIFIER ::= { networking 22 } staticRouteNextHopTable OBJECT-TYPE SYNTAX SEQUENCE OF StaticRouteNextHopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration of static next-hop." ::= { staticRouteNextHop 1 } staticRouteNextHopEntry OBJECT-TYPE SYNTAX StaticRouteNextHopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of staticRouteNextHopTable" INDEX { routingProtocolRtpType,routingProtocolRtpName,staticRouteDestinationPrefix,staticRouteNextHopEntryIndex } ::= { staticRouteNextHopTable 1 } StaticRouteNextHopEntry ::= SEQUENCE { staticRouteNextHopEntryIndex OCTET STRING, staticRouteNextHopEntryOutgoingInterface RowPointer, staticRouteNextHopEntryNextHopAddress IetfInetTypesIpAddress, staticRouteNextHopEntryMetric Unsigned32 } staticRouteNextHopEntryIndex OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "An user-specified identifier utilised to uniquely reference the next-hop entry in the next-hop list. The value of this index has no semantic meaning other than for referencing the entry. " ::= { staticRouteNextHopEntry 1 } staticRouteNextHopEntryOutgoingInterface OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Reference of the outgoing interface. " ::= { staticRouteNextHopEntry 2 } staticRouteNextHopEntryNextHopAddress OBJECT-TYPE SYNTAX IetfInetTypesIpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address of the next-hop. " ::= { staticRouteNextHopEntry 3 } staticRouteNextHopEntryMetric OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "metric of the next-hop. default value :0" ::= { staticRouteNextHopEntry 4 } routeNextHop OBJECT IDENTIFIER ::= { networking 23 } routeNextHopTable OBJECT-TYPE SYNTAX SEQUENCE OF RouteNextHopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration of next-hop." ::= { routeNextHop 1 } routeNextHopEntry OBJECT-TYPE SYNTAX RouteNextHopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of routeNextHopTable" INDEX { ribName,routeSourceProtocol,routeDestinationPrefix } ::= { routeNextHopTable 1 } RouteNextHopEntry ::= SEQUENCE { routeNextHopEntryOutgoingInterface RowPointer, routeNextHopEntryNextHopAddress IetfInetTypesIpAddress, routeNextHopEntrySourceAddress IetfInetTypesIpAddress } routeNextHopEntryOutgoingInterface OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Reference of the outgoing interface. " ::= { routeNextHopEntry 1 } routeNextHopEntryNextHopAddress OBJECT-TYPE SYNTAX IetfInetTypesIpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IPv4 address of the next-hop. " ::= { routeNextHopEntry 2 } routeNextHopEntrySourceAddress OBJECT-TYPE SYNTAX IetfInetTypesIpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "source address of packet out chosen by kernel if the source address has not been chosen by applcation. " ::= { routeNextHopEntry 3 } bgp OBJECT IDENTIFIER ::= { networking 24 } bgpTable OBJECT-TYPE SYNTAX SEQUENCE OF BgpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Top-level configuration for the BGP router" ::= { bgp 1 } bgpEntry OBJECT-TYPE SYNTAX BgpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of bgpTable" INDEX { routingProtocolRtpType,routingProtocolRtpName } ::= { bgpTable 1 } BgpEntry ::= SEQUENCE { bgpAdminStatus INTEGER, bgpOperStatus INTEGER, bgpAliasName OCTET STRING, bgpAs IetfInetTypesAsNumber, bgpRouterId IetfYangTypesDottedQuad } bgpAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :down" ::= { bgpEntry 1 } bgpOperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :up" ::= { bgpEntry 2 } bgpAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined alias for this entity. Must be an alphanumeric string with dash or underscore " ::= { bgpEntry 3 } bgpAs OBJECT-TYPE SYNTAX IetfInetTypesAsNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Local autonomous system number of the router. Uses the 32-bit as-number type from the model in RFC 6991. " ::= { bgpEntry 4 } bgpRouterId OBJECT-TYPE SYNTAX IetfYangTypesDottedQuad MAX-ACCESS read-only STATUS current DESCRIPTION "Router id of the router - an unsigned 32-bit integer expressed in dotted quad notation. " ::= { bgpEntry 5 } bgpNeighborTimers OBJECT IDENTIFIER ::= { bgp 2 } bgpNeighborTimersTable OBJECT-TYPE SYNTAX SEQUENCE OF BgpNeighborTimersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Timers related to a BGP neighbor" ::= { bgpNeighborTimers 1 } bgpNeighborTimersEntry OBJECT-TYPE SYNTAX BgpNeighborTimersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of bgpNeighborTimersTable" INDEX { routingProtocolRtpType,routingProtocolRtpName,bgpNeighborNeighborAddress } ::= { bgpNeighborTimersTable 1 } BgpNeighborTimersEntry ::= SEQUENCE { bgpNeighborTimersConnectRetry OCTET STRING, bgpNeighborTimersHoldTime OCTET STRING, bgpNeighborTimersKeepaliveInterval OCTET STRING, bgpNeighborTimersMinimumAdvertisementInterval OCTET STRING, bgpNeighborTimersNegotiatedHoldTime OCTET STRING } bgpNeighborTimersConnectRetry OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Time interval in seconds between attempts to establish a session with the peer. UNITS:seconds default value :30" ::= { bgpNeighborTimersEntry 1 } bgpNeighborTimersHoldTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Time interval in seconds that a BGP session will be considered active in the absence of keepalive or other messages from the peer. The hold-time is typically set to 3x the keepalive-interval. UNITS:seconds default value :90" ::= { bgpNeighborTimersEntry 2 } bgpNeighborTimersKeepaliveInterval OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Time interval in seconds between transmission of keepalive messages to the neighbor. Typically set to 1/3 the hold-time. UNITS:seconds default value :30" ::= { bgpNeighborTimersEntry 3 } bgpNeighborTimersMinimumAdvertisementInterval OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum time which must elapse between subsequent UPDATE messages relating to a common set of NLRI being transmitted to a peer. This timer is referred to as MinRouteAdvertisementIntervalTimer by RFC 4721 and serves to reduce the number of UPDATE messages transmitted when a particular set of NLRI exhibit instability. UNITS:seconds default value :30" ::= { bgpNeighborTimersEntry 4 } bgpNeighborTimersNegotiatedHoldTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The negotiated hold-time for the BGP session UNITS:seconds " ::= { bgpNeighborTimersEntry 5 } bgpNeighborTransport OBJECT IDENTIFIER ::= { bgp 3 } bgpNeighborTransportTable OBJECT-TYPE SYNTAX SEQUENCE OF BgpNeighborTransportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Transport session parameters for the BGP neighbor" ::= { bgpNeighborTransport 1 } bgpNeighborTransportEntry OBJECT-TYPE SYNTAX BgpNeighborTransportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of bgpNeighborTransportTable" INDEX { routingProtocolRtpType,routingProtocolRtpName,bgpNeighborNeighborAddress } ::= { bgpNeighborTransportTable 1 } BgpNeighborTransportEntry ::= SEQUENCE { bgpNeighborTransportLocalAddress IetfInetTypesIpAddress, bgpNeighborTransportLocalPort IetfInetTypesPortNumber, bgpNeighborTransportRemoteAddress IetfInetTypesIpAddress, bgpNeighborTransportRemotePort IetfInetTypesPortNumber } bgpNeighborTransportLocalAddress OBJECT-TYPE SYNTAX IetfInetTypesIpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Set the local IP (either IPv4 or IPv6) address to use for the session when sending BGP update messages. This may be expressed as either an IP address or reference to the name of an interface. " ::= { bgpNeighborTransportEntry 1 } bgpNeighborTransportLocalPort OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Local TCP port being used for the TCP session supporting the BGP session " ::= { bgpNeighborTransportEntry 2 } bgpNeighborTransportRemoteAddress OBJECT-TYPE SYNTAX IetfInetTypesIpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Remote address to which the BGP session has been established " ::= { bgpNeighborTransportEntry 3 } bgpNeighborTransportRemotePort OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Remote port being used by the peer for the TCP session supporting the BGP session " ::= { bgpNeighborTransportEntry 4 } bgpNeighbor OBJECT IDENTIFIER ::= { networking 25 } bgpNeighborTable OBJECT-TYPE SYNTAX SEQUENCE OF BgpNeighborEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of BGP neighbors configured on the local system, uniquely identified by peer IPv[46] address" ::= { bgpNeighbor 1 } bgpNeighborEntry OBJECT-TYPE SYNTAX BgpNeighborEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of bgpNeighborTable" INDEX { routingProtocolRtpType,routingProtocolRtpName,bgpNeighborNeighborAddress } ::= { bgpNeighborTable 1 } BgpNeighborEntry ::= SEQUENCE { bgpNeighborNeighborAddress IetfInetTypesIpAddress, bgpNeighborEnabled TruthValue, bgpNeighborPeerAs IetfInetTypesAsNumber, bgpNeighborDescription OCTET STRING, bgpNeighborSessionState INTEGER, bgpNeighborEstablishedTransitions IetfYangTypesCounter64, bgpNeighborSupportedCapabilities OCTET STRING } bgpNeighborNeighborAddress OBJECT-TYPE SYNTAX IetfInetTypesIpAddress (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Address of the BGP peer, either in IPv4 or IPv6 " ::= { bgpNeighborEntry 1 } bgpNeighborEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Whether the BGP peer is enabled. In cases where the enabled leaf is set to false, the local system should not initiate connections to the neighbor, and should not respond to TCP connections attempts from the neighbor. If the state of the BGP session is ESTABLISHED at the time that this leaf is set to false, the BGP session should be ceased. default value :true" ::= { bgpNeighborEntry 2 } bgpNeighborPeerAs OBJECT-TYPE SYNTAX IetfInetTypesAsNumber MAX-ACCESS read-only STATUS current DESCRIPTION "AS number of the peer. " ::= { bgpNeighborEntry 3 } bgpNeighborDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "An optional textual description (intended primarily for use with a peer or group " ::= { bgpNeighborEntry 4 } bgpNeighborSessionState OBJECT-TYPE SYNTAX INTEGER { idle (1), connect (2), active (3), opensent (4), openconfirm (5), established (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Operational state of the BGP peer default value :IDLE" ::= { bgpNeighborEntry 5 } bgpNeighborEstablishedTransitions OBJECT-TYPE SYNTAX IetfYangTypesCounter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of transitions to the Established state for the neighbor session. This value is analogous to the bgpPeerFsmEstablishedTransitions object from the standard BGP-4 MIB " ::= { bgpNeighborEntry 6 } bgpNeighborSupportedCapabilities OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "BGP capabilities negotiated as supported with the peerThis is a leaf list, encode by some leafs. " ::= { bgpNeighborEntry 7 } hmoRoute OBJECT IDENTIFIER ::= { networking 26 } hmoRouteTable OBJECT-TYPE SYNTAX SEQUENCE OF HmoRouteEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of routes from static/ospfv2/bgp." ::= { hmoRoute 1 } hmoRouteEntry OBJECT-TYPE SYNTAX HmoRouteEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of hmoRouteTable" INDEX { ribName,hmoRouteSourceProtocol,hmoRouteDestinationPrefix } ::= { hmoRouteTable 1 } HmoRouteEntry ::= SEQUENCE { hmoRouteSourceProtocol CoriantTypesSourceProtocol, hmoRouteDestinationPrefix IetfInetTypesIpPrefix } hmoRouteSourceProtocol OBJECT-TYPE SYNTAX CoriantTypesSourceProtocol MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the routing protocol from which the route originated. " ::= { hmoRouteEntry 1 } hmoRouteDestinationPrefix OBJECT-TYPE SYNTAX IetfInetTypesIpPrefix (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "IP destination prefix. " ::= { hmoRouteEntry 2 } hmoRouteNextHop OBJECT IDENTIFIER ::= { networking 27 } hmoRouteNextHopTable OBJECT-TYPE SYNTAX SEQUENCE OF HmoRouteNextHopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration of next-hop." ::= { hmoRouteNextHop 1 } hmoRouteNextHopEntry OBJECT-TYPE SYNTAX HmoRouteNextHopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of hmoRouteNextHopTable" INDEX { ribName,hmoRouteSourceProtocol,hmoRouteDestinationPrefix } ::= { hmoRouteNextHopTable 1 } HmoRouteNextHopEntry ::= SEQUENCE { hmoRouteNextHopEntryOutgoingInterface RowPointer, hmoRouteNextHopEntryNextHopAddress IetfInetTypesIpAddress, hmoRouteNextHopEntrySourceAddress IetfInetTypesIpAddress } hmoRouteNextHopEntryOutgoingInterface OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Reference of the outgoing interface. " ::= { hmoRouteNextHopEntry 1 } hmoRouteNextHopEntryNextHopAddress OBJECT-TYPE SYNTAX IetfInetTypesIpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IPv4 address of the next-hop. " ::= { hmoRouteNextHopEntry 2 } hmoRouteNextHopEntrySourceAddress OBJECT-TYPE SYNTAX IetfInetTypesIpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "source address of packet out chosen by kernel if the source address has not been chosen by applcation. " ::= { hmoRouteNextHopEntry 3 } neighbors OBJECT IDENTIFIER ::= { networking 28 } neighborsTable OBJECT-TYPE SYNTAX SEQUENCE OF NeighborsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { neighbors 1 } neighborsEntry OBJECT-TYPE SYNTAX NeighborsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of neighborsTable" INDEX { neighborsAddressFamily } ::= { neighborsTable 1 } NeighborsEntry ::= SEQUENCE { neighborsAddressFamily OCTET STRING } neighborsAddressFamily OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The address-family of the neighbor. " ::= { neighborsEntry 1 } neighbor OBJECT IDENTIFIER ::= { networking 29 } neighborTable OBJECT-TYPE SYNTAX SEQUENCE OF NeighborEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of mappings from IP addresses to link-layer addresses." ::= { neighbor 1 } neighborEntry OBJECT-TYPE SYNTAX NeighborEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of neighborTable" INDEX { neighborsAddressFamily,neighborIp } ::= { neighborTable 1 } NeighborEntry ::= SEQUENCE { neighborIp IetfInetTypesIpAddressNoZone, neighborLinkLayerAddress IetfYangTypesPhysAddress, neighborOrigin INTEGER, neighborOutgoingInterface RowPointer, neighborVlanDevName OCTET STRING } neighborIp OBJECT-TYPE SYNTAX IetfInetTypesIpAddressNoZone (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the neighbor node. " ::= { neighborEntry 1 } neighborLinkLayerAddress OBJECT-TYPE SYNTAX IetfYangTypesPhysAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The link-layer address of the neighbor node. " ::= { neighborEntry 2 } neighborOrigin OBJECT-TYPE SYNTAX INTEGER { other (0), static (1), dynamic (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The origin of this neighbor entry. " ::= { neighborEntry 3 } neighborOutgoingInterface OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Interface to the neighbor node. " ::= { neighborEntry 4 } neighborVlanDevName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The VLAN device name. " ::= { neighborEntry 5 } padENTR OBJECT IDENTIFIER ::= { networking 32 } padENTRTable OBJECT-TYPE SYNTAX SEQUENCE OF PadENTREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Peer Authorization Database (PAD) entry." ::= { padENTR 1 } padENTREntry OBJECT-TYPE SYNTAX PadENTREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of padENTRTable" INDEX { padENTRName } ::= { padENTRTable 1 } PadENTREntry ::= SEQUENCE { padENTRName OCTET STRING } padENTRName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "PAD unique name to identify this entry. " ::= { padENTREntry 1 } peerAuthentication OBJECT IDENTIFIER ::= { networking 33 } peerAuthenticationTable OBJECT-TYPE SYNTAX SEQUENCE OF PeerAuthenticationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This container allows the Security Controller to configure the authentication method (pre-shared key, eap, digitial-signature, null) that will use a particular peer and the credentials, which will depend on the selected authentication method." ::= { peerAuthentication 1 } peerAuthenticationEntry OBJECT-TYPE SYNTAX PeerAuthenticationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of peerAuthenticationTable" INDEX { padENTRName } ::= { peerAuthenticationTable 1 } PeerAuthenticationEntry ::= SEQUENCE { peerAuthenticationAuthMethod INTEGER } peerAuthenticationAuthMethod OBJECT-TYPE SYNTAX INTEGER { preShared (0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of authentication method. default value :pre-shared" ::= { peerAuthenticationEntry 1 } preShared OBJECT IDENTIFIER ::= { networking 34 } preSharedTable OBJECT-TYPE SYNTAX SEQUENCE OF PreSharedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Shared secret value for PSK." ::= { preShared 1 } preSharedEntry OBJECT-TYPE SYNTAX PreSharedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of preSharedTable" INDEX { padENTRName } ::= { preSharedTable 1 } PreSharedEntry ::= SEQUENCE { preSharedSecret IetfYangTypesHexString } preSharedSecret OBJECT-TYPE SYNTAX IetfYangTypesHexString MAX-ACCESS read-only STATUS current DESCRIPTION "Pre-shared secret value. " ::= { preSharedEntry 1 } connENTR OBJECT IDENTIFIER ::= { networking 35 } connENTRTable OBJECT-TYPE SYNTAX SEQUENCE OF ConnENTREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IKE peer connection information. This list contains the IKE connection for this peer with other peers. This will be translated in real time by IKE Security Associations established with these nodes." ::= { connENTR 1 } connENTREntry OBJECT-TYPE SYNTAX ConnENTREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of connENTRTable" INDEX { connENTRName } ::= { connENTRTable 1 } ConnENTREntry ::= SEQUENCE { connENTRName OCTET STRING, connENTRIkeVersion INTEGER, connENTRAdminStatus INTEGER, connENTROperStatus INTEGER, connENTRAuthalg OCTET STRING, connENTREncalg OCTET STRING, connENTRDhGroup IpsecDhGroup, connENTRLocalAddress IetfInetTypesIpAddress, connENTRLocalPadEntryRef RowPointer, connENTRRemoteAddress IetfInetTypesIpAddress, connENTRRemotePadEntryRef RowPointer } connENTRName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier for this connection entry. " ::= { connENTREntry 1 } connENTRIkeVersion OBJECT-TYPE SYNTAX INTEGER { ikev2 (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "IKE version. Only version 2 is supported so far. default value :ikev2" ::= { connENTREntry 2 } connENTRAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :down" ::= { connENTREntry 3 } connENTROperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :down" ::= { connENTREntry 4 } connENTRAuthalg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Authentication algorithm for establishing the IKE SA.This is a leaf list, encode by some leafs. " ::= { connENTREntry 5 } connENTREncalg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Encryption algorithm for the IKE SAs.This is a leaf list, encode by some leafs. " ::= { connENTREntry 6 } connENTRDhGroup OBJECT-TYPE SYNTAX IpsecDhGroup MAX-ACCESS read-only STATUS current DESCRIPTION "Group number for Diffie-Hellman Exponentiation used during IKE_SA_INIT for the IKE SA key exchange. default value :14" ::= { connENTREntry 7 } connENTRLocalAddress OBJECT-TYPE SYNTAX IetfInetTypesIpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "local address. " ::= { connENTREntry 8 } connENTRLocalPadEntryRef OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Local peer authentication information. This node points to a specific entry in the PAD where the authorization information about this particular local peer is stored. It MUST match a pad-entry-name. " ::= { connENTREntry 9 } connENTRRemoteAddress OBJECT-TYPE SYNTAX IetfInetTypesIpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "remote address. " ::= { connENTREntry 10 } connENTRRemotePadEntryRef OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Remote peer authentication information. This node points to a specific entry in the PAD where the authorization information about this particular remote peer is stored. It MUST match a pad-entry-name. " ::= { connENTREntry 11 } ikeSaLifetime OBJECT IDENTIFIER ::= { networking 36 } ikeSaLifetimeTable OBJECT-TYPE SYNTAX SEQUENCE OF IkeSaLifetimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IKE SA lifetime soft. Two lifetime values can be configured: either rekey time of the IKE SA or reauth time of the IKE SA. When the rekey lifetime expires a rekey of the IKE SA starts. When reauth lifetime expires a IKE SA reauthentication starts." ::= { ikeSaLifetime 1 } ikeSaLifetimeEntry OBJECT-TYPE SYNTAX IkeSaLifetimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ikeSaLifetimeTable" INDEX { connENTRName } ::= { ikeSaLifetimeTable 1 } IkeSaLifetimeEntry ::= SEQUENCE { ikeSaLifetimeRekeyTime Unsigned32, ikeSaLifetimeReauthTime Unsigned32 } ikeSaLifetimeRekeyTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Time in seconds between each IKE SA rekey.The value 0 means infinite. default value :86400" ::= { ikeSaLifetimeEntry 1 } ikeSaLifetimeReauthTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Time in seconds between each IKE SA reauthentication. The value 0 means infinite. default value :86400" ::= { ikeSaLifetimeEntry 2 } spdENTR OBJECT IDENTIFIER ::= { networking 40 } spdENTRTable OBJECT-TYPE SYNTAX SEQUENCE OF SpdENTREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of entries which will constitute the representation of the SPD. Since we have IKE in this case, it is only required to send a IPsec policy from this NE where 'local' is this NE and 'remote' the other NE. The IKE implementation will install IPsec policies in the NE in both directions (inbound and outbound) and their corresponding IPsec SAs based on the information in this SPD entry." ::= { spdENTR 1 } spdENTREntry OBJECT-TYPE SYNTAX SpdENTREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of spdENTRTable" INDEX { connENTRName,spdENTRSpdEntryName } ::= { spdENTRTable 1 } SpdENTREntry ::= SEQUENCE { spdENTRAdminStatus INTEGER, spdENTROperStatus INTEGER, spdENTRSpdEntryName OCTET STRING } spdENTRAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :down" ::= { spdENTREntry 3 } spdENTROperStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state specifies whether or not a resource is able to provide service. The operational state shall be visible to the operator. The user cannot modify the operational state. It provides a simple mechanism for the operator to decide whether a resource is operational or not, therefore this parameter has a read-only nature. The operational state is closely coupled with the alarm status of a resource, i.e. state transitions are triggered internally by the NE software. It can have one of the following values: Down: The resource is totally inoperable and unable to provide service to the user(s) Up: The resource is partially or fully operable and available for use. default value :down" ::= { spdENTREntry 4 } spdENTRSpdEntryName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "SPD entry unique name to identify the IPsec policy. " ::= { spdENTREntry 5 } trafficSelector OBJECT IDENTIFIER ::= { networking 42 } trafficSelectorTable OBJECT-TYPE SYNTAX SEQUENCE OF TrafficSelectorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Packets are selected for processing actions based on the IP and inner protocol header information, selectors, matched against entries in the SPD." ::= { trafficSelector 1 } trafficSelectorEntry OBJECT-TYPE SYNTAX TrafficSelectorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of trafficSelectorTable" INDEX { connENTRName,spdENTRSpdEntryName } ::= { trafficSelectorTable 1 } TrafficSelectorEntry ::= SEQUENCE { trafficSelectorLocalSubnet IetfInetTypesIpPrefix, trafficSelectorRemoteSubnet IetfInetTypesIpPrefix, trafficSelectorInnerProtocol IpsecIpsecInnerProtocol } trafficSelectorLocalSubnet OBJECT-TYPE SYNTAX IetfInetTypesIpPrefix MAX-ACCESS read-only STATUS current DESCRIPTION "Local IP address subnet. " ::= { trafficSelectorEntry 1 } trafficSelectorRemoteSubnet OBJECT-TYPE SYNTAX IetfInetTypesIpPrefix MAX-ACCESS read-only STATUS current DESCRIPTION "Remote IP address subnet. " ::= { trafficSelectorEntry 2 } trafficSelectorInnerProtocol OBJECT-TYPE SYNTAX IpsecIpsecInnerProtocol MAX-ACCESS read-only STATUS current DESCRIPTION "Inner Protocol that is going to be protected with IPsec. default value :any" ::= { trafficSelectorEntry 3 } localPorts OBJECT IDENTIFIER ::= { networking 43 } localPortsTable OBJECT-TYPE SYNTAX SEQUENCE OF LocalPortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of local ports. When the inner protocol is ICMP this 16 bit value represents code and type." ::= { localPorts 1 } localPortsEntry OBJECT-TYPE SYNTAX LocalPortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of localPortsTable" INDEX { connENTRName,spdENTRSpdEntryName,localPortsStart,localPortsEnd } ::= { localPortsTable 1 } LocalPortsEntry ::= SEQUENCE { localPortsStart IetfInetTypesPortNumber, localPortsEnd IetfInetTypesPortNumber } localPortsStart OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Start port number. " ::= { localPortsEntry 1 } localPortsEnd OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "End port number. " ::= { localPortsEntry 2 } remotePorts OBJECT IDENTIFIER ::= { networking 44 } remotePortsTable OBJECT-TYPE SYNTAX SEQUENCE OF RemotePortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of remote ports. When the upper layer protocol is ICMP this 16 bit value represents code and type." ::= { remotePorts 1 } remotePortsEntry OBJECT-TYPE SYNTAX RemotePortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of remotePortsTable" INDEX { connENTRName,spdENTRSpdEntryName,remotePortsStart,remotePortsEnd } ::= { remotePortsTable 1 } RemotePortsEntry ::= SEQUENCE { remotePortsStart IetfInetTypesPortNumber, remotePortsEnd IetfInetTypesPortNumber } remotePortsStart OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Start port number. " ::= { remotePortsEntry 1 } remotePortsEnd OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "End port number. " ::= { remotePortsEntry 2 } processingInfo OBJECT IDENTIFIER ::= { networking 45 } processingInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF ProcessingInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "SPD processing. If the required processing action is protect, it contains the required information to process the packet." ::= { processingInfo 1 } processingInfoEntry OBJECT-TYPE SYNTAX ProcessingInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of processingInfoTable" INDEX { connENTRName,spdENTRSpdEntryName } ::= { processingInfoTable 1 } ProcessingInfoEntry ::= SEQUENCE { processingInfoAction INTEGER } processingInfoAction OBJECT-TYPE SYNTAX INTEGER { protect (0), bypass (1), discard (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "If bypass or discard, container ipsec-sa-cfg is empty. default value :protect" ::= { processingInfoEntry 1 } ipsecSaCfg OBJECT IDENTIFIER ::= { networking 46 } ipsecSaCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF IpsecSaCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IPsec SA configuration included in the SPD entry." ::= { ipsecSaCfg 1 } ipsecSaCfgEntry OBJECT-TYPE SYNTAX IpsecSaCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ipsecSaCfgTable" INDEX { connENTRName,spdENTRSpdEntryName } ::= { ipsecSaCfgTable 1 } IpsecSaCfgEntry ::= SEQUENCE { ipsecSaCfgMode INTEGER, ipsecSaCfgProtocolParameters INTEGER } ipsecSaCfgMode OBJECT-TYPE SYNTAX INTEGER { transport (0), tunnel (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "IPsec SA has to be processed in transport or tunnel mode. default value :transport" ::= { ipsecSaCfgEntry 1 } ipsecSaCfgProtocolParameters OBJECT-TYPE SYNTAX INTEGER { esp (0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Security protocol of the IPsec SA: Only ESP is supported but it could be extended in the future. default value :esp" ::= { ipsecSaCfgEntry 2 } espAlgorithms OBJECT IDENTIFIER ::= { networking 47 } espAlgorithmsTable OBJECT-TYPE SYNTAX SEQUENCE OF EspAlgorithmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration of Encapsulating Security Payload (ESP) parameters and algorithms." ::= { espAlgorithms 1 } espAlgorithmsEntry OBJECT-TYPE SYNTAX EspAlgorithmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of espAlgorithmsTable" INDEX { connENTRName,spdENTRSpdEntryName } ::= { espAlgorithmsTable 1 } EspAlgorithmsEntry ::= SEQUENCE { espAlgorithmsIntegrity OCTET STRING, espAlgorithmsEncryption OCTET STRING } espAlgorithmsIntegrity OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Configuration of ESP authentication based on the specified integrity algorithm. With AEAD algorithms, the integrity node is not used.This is a leaf list, encode by some leafs. " ::= { espAlgorithmsEntry 1 } espAlgorithmsEncryption OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Configuration of ESP encryption algorithms.This is a leaf list, encode by some leafs. " ::= { espAlgorithmsEntry 2 } childSaInfo OBJECT IDENTIFIER ::= { networking 48 } childSaInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF ChildSaInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Specific information for IPsec SAs SAs. It includes PFS group and IPsec SAs rekey lifetimes." ::= { childSaInfo 1 } childSaInfoEntry OBJECT-TYPE SYNTAX ChildSaInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of childSaInfoTable" INDEX { connENTRName } ::= { childSaInfoTable 1 } ChildSaInfoEntry ::= SEQUENCE { childSaInfoPfsGroups OCTET STRING } childSaInfoPfsGroups OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "perfect forward secrecy group numbers.This is a leaf list, encode by some leafs. " ::= { childSaInfoEntry 1 } childSaLifetime OBJECT IDENTIFIER ::= { networking 49 } childSaLifetimeTable OBJECT-TYPE SYNTAX SEQUENCE OF ChildSaLifetimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IPsec SA lifetime soft." ::= { childSaLifetime 1 } childSaLifetimeEntry OBJECT-TYPE SYNTAX ChildSaLifetimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of childSaLifetimeTable" INDEX { connENTRName } ::= { childSaLifetimeTable 1 } ChildSaLifetimeEntry ::= SEQUENCE { childSaLifetimeTime Unsigned32, childSaLifetimeBytes Unsigned32 } childSaLifetimeTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Time in seconds since the IPsec SA was added. For example, if this value is 180 seconds it means the IPsec SA expires in 180 seconds since it was added. The value 0 implies infinite. default value :28800" ::= { childSaLifetimeEntry 1 } childSaLifetimeBytes OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "If the IPsec SA processes the number of bytes expressed in this leaf, the IPsec SA expires and should be rekeyed. The value 0 implies infinite. default value :0" ::= { childSaLifetimeEntry 2 } ikeState OBJECT IDENTIFIER ::= { networking 51 } ikeStateTable OBJECT-TYPE SYNTAX SEQUENCE OF IkeStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IKE state data for a particular connection." ::= { ikeState 1 } ikeStateEntry OBJECT-TYPE SYNTAX IkeStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ikeStateTable" INDEX { connENTRName } ::= { ikeStateTable 1 } IkeStateEntry ::= SEQUENCE { ikeStateInitiator TruthValue, ikeStateInitiatorIkesaSpi OCTET STRING, ikeStateResponderIkesaSpi OCTET STRING, ikeStateEstablished OCTET STRING, ikeStateCurrentRekeyTime OCTET STRING, ikeStateCurrentReauthTime OCTET STRING } ikeStateInitiator OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "It is acting as initiator for this connection. " ::= { ikeStateEntry 1 } ikeStateInitiatorIkesaSpi OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Initiator's IKE SA SPI. " ::= { ikeStateEntry 2 } ikeStateResponderIkesaSpi OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Responder's IKE SA SPI. " ::= { ikeStateEntry 3 } ikeStateEstablished OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Seconds since this IKE SA has been established. " ::= { ikeStateEntry 4 } ikeStateCurrentRekeyTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Seconds before IKE SA must be rekeyed. " ::= { ikeStateEntry 5 } ikeStateCurrentReauthTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Seconds before IKE SA must be re-authenticated. " ::= { ikeStateEntry 6 } acl OBJECT IDENTIFIER ::= { networking 52 } aclTable OBJECT-TYPE SYNTAX SEQUENCE OF AclEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An ACL is an ordered list of ACEs. Each ACE has a list of match criteria and a list of actions." ::= { acl 1 } aclEntry OBJECT-TYPE SYNTAX AclEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of aclTable" INDEX { aclName } ::= { aclTable 1 } AclEntry ::= SEQUENCE { aclName OCTET STRING, aclType INTEGER } aclName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the access list. " ::= { aclEntry 1 } aclType OBJECT-TYPE SYNTAX INTEGER { ipv4AclType (0), ipv6AclType (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of ACL. Indicates the primary intended type of match criteria (e.g., Ethernet, IPv4, IPv6, mixed, etc.) used in the list instance. " ::= { aclEntry 2 } ace OBJECT IDENTIFIER ::= { networking 53 } aceTable OBJECT-TYPE SYNTAX SEQUENCE OF AceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of ACEs." ::= { ace 1 } aceEntry OBJECT-TYPE SYNTAX AceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of aceTable" INDEX { aclName,aceSequenceId } ::= { aceTable 1 } AceEntry ::= SEQUENCE { aceSequenceId Unsigned32, aceLabel OCTET STRING, aceForwardingAction INTEGER } aceSequenceId OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Sequence number that establishes the relative order of the ACE within an ACL " ::= { aceEntry 2 } aceLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique name identifying this ACE. " ::= { aceEntry 3 } aceForwardingAction OBJECT-TYPE SYNTAX INTEGER { accept (0), drop (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the forwarding action per ace entry. " ::= { aceEntry 4 } aclSet OBJECT IDENTIFIER ::= { networking 58 } aclSetTable OBJECT-TYPE SYNTAX SEQUENCE OF AclSetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of ACLs on local service." ::= { aclSet 1 } aclSetEntry OBJECT-TYPE SYNTAX AclSetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of aclSetTable" INDEX { aclLocalServiceService,aclSetName } ::= { aclSetTable 1 } AclSetEntry ::= SEQUENCE { aclSetName OCTET STRING } aclSetName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Reference to the ACL name applied on the local network services. " ::= { aclSetEntry 1 } aclIpv4 OBJECT IDENTIFIER ::= { networking 59 } aclIpv4Table OBJECT-TYPE SYNTAX SEQUENCE OF AclIpv4Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Rule set that matches IPv4 headers." ::= { aclIpv4 1 } aclIpv4Entry OBJECT-TYPE SYNTAX AclIpv4Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of aclIpv4Table" INDEX { aclName,aceSequenceId } ::= { aclIpv4Table 1 } AclIpv4Entry ::= SEQUENCE { aclIpv4SourceIpv4Network IetfInetTypesIpv4Prefix, aclIpv4Protocol Unsigned32 } aclIpv4SourceIpv4Network OBJECT-TYPE SYNTAX IetfInetTypesIpv4Prefix MAX-ACCESS read-only STATUS current DESCRIPTION "Source IPv4 address prefix. " ::= { aclIpv4Entry 1 } aclIpv4Protocol OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Internet Protocol number. Refers to the protocol of the payload. " ::= { aclIpv4Entry 2 } aclIpv6 OBJECT IDENTIFIER ::= { networking 60 } aclIpv6Table OBJECT-TYPE SYNTAX SEQUENCE OF AclIpv6Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Rule set that matches IPv6 headers." ::= { aclIpv6 1 } aclIpv6Entry OBJECT-TYPE SYNTAX AclIpv6Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of aclIpv6Table" INDEX { aclName,aceSequenceId } ::= { aclIpv6Table 1 } AclIpv6Entry ::= SEQUENCE { aclIpv6SourceIpv6Network IetfInetTypesIpv6Prefix, aclIpv6Protocol Unsigned32 } aclIpv6SourceIpv6Network OBJECT-TYPE SYNTAX IetfInetTypesIpv6Prefix MAX-ACCESS read-only STATUS current DESCRIPTION "Source IPv6 address prefix. " ::= { aclIpv6Entry 1 } aclIpv6Protocol OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Internet Protocol number. Refers to the protocol of the payload. In IPv6, this field is known as 'next-header', and if extension headers are present, the protocol is present in the 'upper-layer' header. " ::= { aclIpv6Entry 2 } aclTcp OBJECT IDENTIFIER ::= { networking 61 } aclTcpTable OBJECT-TYPE SYNTAX SEQUENCE OF AclTcpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Rule set that matches TCP headers." ::= { aclTcp 1 } aclTcpEntry OBJECT-TYPE SYNTAX AclTcpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of aclTcpTable" INDEX { aclName,aceSequenceId } ::= { aclTcpTable 1 } AclTcpEntry ::= SEQUENCE { aclTcpDestinationLowerPort IetfInetTypesPortNumber, aclTcpDestinationUpperPort IetfInetTypesPortNumber } aclTcpDestinationLowerPort OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Lower boundary for a port. " ::= { aclTcpEntry 1 } aclTcpDestinationUpperPort OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Upper boundary for a port. " ::= { aclTcpEntry 2 } aclUdp OBJECT IDENTIFIER ::= { networking 62 } aclUdpTable OBJECT-TYPE SYNTAX SEQUENCE OF AclUdpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Rule set that matches UDP headers." ::= { aclUdp 1 } aclUdpEntry OBJECT-TYPE SYNTAX AclUdpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of aclUdpTable" INDEX { aclName,aceSequenceId } ::= { aclUdpTable 1 } AclUdpEntry ::= SEQUENCE { aclUdpDestinationLowerPort IetfInetTypesPortNumber, aclUdpDestinationUpperPort IetfInetTypesPortNumber } aclUdpDestinationLowerPort OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Lower boundary for a port. " ::= { aclUdpEntry 1 } aclUdpDestinationUpperPort OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Upper boundary for a port. " ::= { aclUdpEntry 2 } aclLocalService OBJECT IDENTIFIER ::= { networking 63 } aclLocalServiceTable OBJECT-TYPE SYNTAX SEQUENCE OF AclLocalServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ACL attachment point of all the local network services." ::= { aclLocalService 1 } aclLocalServiceEntry OBJECT-TYPE SYNTAX AclLocalServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of aclLocalServiceTable" INDEX { aclLocalServiceService } ::= { aclLocalServiceTable 1 } AclLocalServiceEntry ::= SEQUENCE { aclLocalServiceService INTEGER } aclLocalServiceService OBJECT-TYPE SYNTAX INTEGER { all (0), ssh (1), cli (2), snmp (3), netconf (4), restconf (5), webgui (6), grpc (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { aclLocalServiceEntry 1 } security OBJECT IDENTIFIER ::= { groove 7 } securityInfo OBJECT IDENTIFIER ::= { security 1 } securitySshPublicKey OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3000)) MAX-ACCESS read-only STATUS current DESCRIPTION "The system's public key for use with SSH or SFTP.This is a leaf list, encode by some leafs. " ::= { securityInfo 1 } securitySshPublicKeyFingerprint OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "The fingerprint of the system's public key.This is a leaf list, encode by some leafs. " ::= { securityInfo 2 } securityPreLoginMessage OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..1440)) MAX-ACCESS read-only STATUS current DESCRIPTION "Welcome message displayed before user login default value :****************************************** Warning ****************************************** This system is restricted to authorized users for business purposes. Unauthorized access is a violation of the law. This service may be monitored for administrative and security reasons. By proceeding, you consent to this monitoring. ********************************************************************************************* " ::= { securityInfo 3 } securityWarningMessage OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..1440)) MAX-ACCESS read-only STATUS current DESCRIPTION "Welcome message displayed after user login default value :****************************************** Warning ****************************************** This system is restricted to authorized users for business purposes. Unauthorized access is a violation of the law. This service may be monitored for administrative and security reasons. By proceeding, you consent to this monitoring. ********************************************************************************************* " ::= { securityInfo 4 } securityAaaAuthenticationMethod OBJECT-TYPE SYNTAX INTEGER { localOnly (1), localFirstThenRemote (3), remoteFirstThenLocal (4), remoteUnavailableThenLocal (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "specify authentication method for the user login to the NE. default value :local-only" ::= { securityInfo 5 } securitySystemFips OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "specifies whether the system security is operating in compliance with FIPS. default value :disabled" ::= { securityInfo 6 } securityHttpSupport OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Defines whether unsecure HTTP protocol is allowed; includes file transfer, or any other application that uses HTTP default value :disabled" ::= { securityInfo 7 } securityStrictPasswordCheck OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Defines whether system password follow strict checking default value :enabled" ::= { securityInfo 8 } securityGrpcLocalCertificate OBJECT-TYPE SYNTAX SecurityGrpcCertificateRef MAX-ACCESS read-only STATUS current DESCRIPTION "Certificate for gRPC dial-in server and dial-out client. default value :none" ::= { securityInfo 9 } securityHttpsLocalCertificate OBJECT-TYPE SYNTAX SecurityLocalCertificateRef MAX-ACCESS read-only STATUS current DESCRIPTION "Certificate for both WebGUI https server and RESTCONF https server. default value :none" ::= { securityInfo 10 } securityGrpcDialOutTrustedCertgrp OBJECT-TYPE SYNTAX SecurityTrustedCertificateGroupRef MAX-ACCESS read-only STATUS current DESCRIPTION "trusted certificate group for gRPC dial-out client. default value :none" ::= { securityInfo 11 } securityGrpcDialInTrustedCertgrp OBJECT-TYPE SYNTAX SecurityTrustedCertificateGroupRef MAX-ACCESS read-only STATUS current DESCRIPTION "trusted certificate group for gRPC dial-in server. default value :none" ::= { securityInfo 12 } securityGrpcDialOutAuthentication OBJECT-TYPE SYNTAX INTEGER { none (0), tlsUniAuth (1), tlsMutualAuth (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL default value :none" ::= { securityInfo 13 } securityGrpcDialInAuthentication OBJECT-TYPE SYNTAX INTEGER { none (0), tlsUniAuth (1), tlsMutualAuth (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "NULL default value :none" ::= { securityInfo 14 } securityRestconfHttpsTrustedCertgrp OBJECT-TYPE SYNTAX SecurityTrustedCertificateGroupRef MAX-ACCESS read-only STATUS current DESCRIPTION "Certificate group for RESTCONF https server. default value :none" ::= { securityInfo 16 } securityRestconfHttpsAuthentication OBJECT-TYPE SYNTAX INTEGER { tlsUniAuth (0), tlsMutualAuth (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Update TLS auth for RESTCONF Conditions:/ne/system/restconf/rest-https-support = 'enabled' default value :tls-uni-auth" ::= { securityInfo 17 } securityCspSymmetricalKey OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Critical Security Parameters symmetrical key. " ::= { securityInfo 18 } securitySshSha1Support OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Defines if ssh-sha1 is enabled for SSH. This applies to sha-1 hash and HMAC. default value :enabled" ::= { securityInfo 19 } user OBJECT IDENTIFIER ::= { security 2 } userTable OBJECT-TYPE SYNTAX SEQUENCE OF UserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { user 1 } userEntry OBJECT-TYPE SYNTAX UserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of userTable" INDEX { userName } ::= { userTable 1 } UserEntry ::= SEQUENCE { userName CoriantTypesUserName, userPassword OCTET STRING, userClass INTEGER, userMaxInvalidLogin Unsigned32, userSuspensionTime Unsigned32, userTimeout Unsigned32, userPasswordAgingInterval Unsigned32, userPasswordExpirationDate IetfYangTypesDateAndTime, userAdminStatus INTEGER, userStatus INTEGER, userMaxSessions Unsigned32, userLastLoginDate IetfYangTypesDateAndTime, userAaaType INTEGER } userName OBJECT-TYPE SYNTAX CoriantTypesUserName MAX-ACCESS read-only STATUS current DESCRIPTION "User name. " ::= { userEntry 1 } userPassword OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The password of the user. " ::= { userEntry 2 } userClass OBJECT-TYPE SYNTAX INTEGER { cryptoOfficer (0), administration (1), configuration (2), operation (3), supervision (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The access class for the user. default value :supervision" ::= { userEntry 3 } userMaxInvalidLogin OBJECT-TYPE SYNTAX Unsigned32 (0..9) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is the maximum number of consecutive and invalid login attempts before an account is suspended (lockedout). Conditions:../user-aaa-type = 'local' default value :3" ::= { userEntry 4 } userSuspensionTime OBJECT-TYPE SYNTAX Unsigned32 (0..300) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is the duration of UID suspension following consecutive invalid login attempts. Setting the value to 0 disables this attribute. Conditions:../user-aaa-type = 'local' UNITS:seconds default value :60" ::= { userEntry 5 } userTimeout OBJECT-TYPE SYNTAX Unsigned32 (0..300) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is the Session Time Out Interval. If there are no messages between the user and the NE over the Time Out interval, the session is logged off. Setting the value to 0 disables this attribute (meaning the session will not time out). UNITS:minutes default value :30" ::= { userEntry 6 } userPasswordAgingInterval OBJECT-TYPE SYNTAX Unsigned32 (0..365) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is the Password Aging Interval. Setting the value to 0 disables this attribute. Conditions:../user-aaa-type = 'local' UNITS:days default value :0" ::= { userEntry 7 } userPasswordExpirationDate OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute shows the password expiration date. Conditions:../user-aaa-type = 'local' " ::= { userEntry 8 } userAdminStatus OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The attribute allows administrators to modify the user administration status. default value :enabled" ::= { userEntry 9 } userStatus OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2), passwordAged (3), lockout (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute shows the user status. User with status 'enabled' will have access to the system. User with status 'disabled' not have access to the system. User with status 'password-aged' will have access to the system but will be forced to change his password on first-time login. User with status 'lockout' means the account is locked out due to unsuccessful login attempts. default value :disabled" ::= { userEntry 10 } userMaxSessions OBJECT-TYPE SYNTAX Unsigned32 (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute specifies the maximum number of sessions allowed for this user. default value :6" ::= { userEntry 11 } userLastLoginDate OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The last login date/time of the user. default value :1970-01-01T00:00:00Z" ::= { userEntry 12 } userAaaType OBJECT-TYPE SYNTAX INTEGER { local (1), remote (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the authentication method of the user. default value :local" ::= { userEntry 13 } session OBJECT IDENTIFIER ::= { security 3 } sessionTable OBJECT-TYPE SYNTAX SEQUENCE OF SessionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { session 1 } sessionEntry OBJECT-TYPE SYNTAX SessionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of sessionTable" INDEX { sessionId } ::= { sessionTable 1 } SessionEntry ::= SEQUENCE { sessionId CoriantTypesSessionId, sessionUser RowPointer, sessionType INTEGER, sessionProtocol INTEGER, sessionCreatedTime IetfYangTypesDateAndTime, sessionMode INTEGER } sessionId OBJECT-TYPE SYNTAX CoriantTypesSessionId MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies a unique identifier of the current session. It indicates the IP address and transport layer port number associated with this session. If the session is initiated from the serial port, the value is 'NA'. " ::= { sessionEntry 1 } sessionUser OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Points to a user instance. Conditions:../session-mode = 'server' " ::= { sessionEntry 2 } sessionType OBJECT-TYPE SYNTAX INTEGER { cli (1), snmp (2), netconf (3), restconf (4), webgui (5), gnmi (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Session type. " ::= { sessionEntry 3 } sessionProtocol OBJECT-TYPE SYNTAX INTEGER { telnet (1), telnetRaw (2), serial (3), ssh (4), sshRaw (5), https (6), http (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates which protocol has been used to establish the session. " ::= { sessionEntry 4 } sessionCreatedTime OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The timestamp the user has created this session. " ::= { sessionEntry 5 } sessionMode OBJECT-TYPE SYNTAX INTEGER { server (1), client (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "the device role in session connection default value :server" ::= { sessionEntry 6 } aaaServer OBJECT IDENTIFIER ::= { security 4 } aaaServerTable OBJECT-TYPE SYNTAX SEQUENCE OF AaaServerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { aaaServer 1 } aaaServerEntry OBJECT-TYPE SYNTAX AaaServerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of aaaServerTable" INDEX { aaaServerServerName } ::= { aaaServerTable 1 } AaaServerEntry ::= SEQUENCE { aaaServerServerName OCTET STRING, aaaServerServerPriority Unsigned32, aaaServerProtocolSupported INTEGER, aaaServerServerIp IetfInetTypesIpAddress, aaaServerServerPort IetfInetTypesPortNumber, aaaServerSharedSecret OCTET STRING, aaaServerRoleSupported BITS, aaaServerAdminStatus INTEGER, aaaServerTimeOut Unsigned32, aaaServerRetry Unsigned32, aaaServerServerPortAuthentication IetfInetTypesPortNumber, aaaServerServerPortAccounting IetfInetTypesPortNumber, aaaServerSourceIp OCTET STRING } aaaServerServerName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "specify the name of aaa server. " ::= { aaaServerEntry 1 } aaaServerServerPriority OBJECT-TYPE SYNTAX Unsigned32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "This is used to sort the servers in the order of precedence. " ::= { aaaServerEntry 2 } aaaServerProtocolSupported OBJECT-TYPE SYNTAX INTEGER { tacacsplus (1), radius (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "specify the protocol used for AAA. " ::= { aaaServerEntry 3 } aaaServerServerIp OBJECT-TYPE SYNTAX IetfInetTypesIpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of AAA server. " ::= { aaaServerEntry 4 } aaaServerServerPort OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "AAA server port number. Conditions:../protocol-supported = 'TACACSPLUS' default value :49" ::= { aaaServerEntry 5 } aaaServerSharedSecret OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..100)) MAX-ACCESS read-only STATUS current DESCRIPTION "The shared secret of the aaa server. The shared secret will be displayed as *. default value :sharedkey" ::= { aaaServerEntry 6 } aaaServerRoleSupported OBJECT-TYPE SYNTAX BITS { authentication (0), authorization (1), accounting (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "specify the role of the server for AAA. default value :authentication authorization accounting" ::= { aaaServerEntry 7 } aaaServerAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { aaaServerEntry 8 } aaaServerTimeOut OBJECT-TYPE SYNTAX Unsigned32 (1..60) MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the response timeout of Access-Request messages sent to a AAA server in seconds. UNITS:seconds default value :5" ::= { aaaServerEntry 9 } aaaServerRetry OBJECT-TYPE SYNTAX Unsigned32 (0..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the number of attempted Access-Request messages to a single AAA server before failing authentication. default value :3" ::= { aaaServerEntry 10 } aaaServerServerPortAuthentication OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "AAA server authentication port number. Conditions:../protocol-supported = 'RADIUS' default value :1812" ::= { aaaServerEntry 11 } aaaServerServerPortAccounting OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "AAA server accounting port number. Conditions:../protocol-supported = 'RADIUS' default value :1813" ::= { aaaServerEntry 12 } aaaServerSourceIp OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Source IP address used for RADIUS communications. Conditions:../protocol-supported = 'RADIUS' default value :auto" ::= { aaaServerEntry 13 } keySyncSession OBJECT IDENTIFIER ::= { security 5 } keySyncSessionTable OBJECT-TYPE SYNTAX SEQUENCE OF KeySyncSessionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "TLS session to synchronize ODU encryption key." ::= { keySyncSession 1 } keySyncSessionEntry OBJECT-TYPE SYNTAX KeySyncSessionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of keySyncSessionTable" INDEX { keySyncSessionId } ::= { keySyncSessionTable 1 } KeySyncSessionEntry ::= SEQUENCE { keySyncSessionId Unsigned32, keySyncSessionAdminStatus INTEGER, keySyncSessionSessionStatus INTEGER, keySyncSessionRemoteIp IetfInetTypesIpv4Address, keySyncSessionRemotePort IetfInetTypesPortNumber, keySyncSessionLocalIp IetfInetTypesIpv4Address, keySyncSessionLocalPort IetfInetTypesPortNumber, keySyncSessionSourceAddressFrom KeySyncSessionInterfaceRef, keySyncSessionConnectedTime IetfYangTypesDateAndTime, keySyncSessionType INTEGER, keySyncSessionAuthType INTEGER, keySyncSessionLocalCertificate KeySyncSessionCertificateRef } keySyncSessionId OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies a unique identifier of the key synchronization session. " ::= { keySyncSessionEntry 1 } keySyncSessionAdminStatus OBJECT-TYPE SYNTAX INTEGER { up (1), down (2), upNoAlm (3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The administrative state specifies the permission to use or prohibition against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource. default value :up" ::= { keySyncSessionEntry 2 } keySyncSessionSessionStatus OBJECT-TYPE SYNTAX INTEGER { unknown (0), disabled (1), connecting (2), incomplete (3), connected (4), unreachable (5), failedAuth (6), failed (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicating the status of key sync session. " ::= { keySyncSessionEntry 4 } keySyncSessionRemoteIp OBJECT-TYPE SYNTAX IetfInetTypesIpv4Address MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of remote session server. " ::= { keySyncSessionEntry 5 } keySyncSessionRemotePort OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The port number of remote session server. default value :8443" ::= { keySyncSessionEntry 6 } keySyncSessionLocalIp OBJECT-TYPE SYNTAX IetfInetTypesIpv4Address MAX-ACCESS read-only STATUS current DESCRIPTION "The source IP address of a manual session. " ::= { keySyncSessionEntry 7 } keySyncSessionLocalPort OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The source port number of a manual session. " ::= { keySyncSessionEntry 8 } keySyncSessionSourceAddressFrom OBJECT-TYPE SYNTAX KeySyncSessionInterfaceRef MAX-ACCESS read-only STATUS current DESCRIPTION "specifies the interface of the source IP address of the outgoing packets. Conditions:../key-sync-session-type = 'manual' default value :auto" ::= { keySyncSessionEntry 9 } keySyncSessionConnectedTime OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The timestamp the user has created this session. " ::= { keySyncSessionEntry 10 } keySyncSessionType OBJECT-TYPE SYNTAX INTEGER { auto (1), manual (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicating the type of key sync session, 'manual' is for the session user configured, and 'auto' is for the session automatically created by system. default value :manual" ::= { keySyncSessionEntry 11 } keySyncSessionAuthType OBJECT-TYPE SYNTAX INTEGER { tlsCertificate (1), proprietaryPsk (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicating the authentication type of the key sync session. default value :proprietary-psk" ::= { keySyncSessionEntry 12 } keySyncSessionLocalCertificate OBJECT-TYPE SYNTAX KeySyncSessionCertificateRef MAX-ACCESS read-only STATUS current DESCRIPTION "Previously installed certificate that authenticates the NE. default value :none" ::= { keySyncSessionEntry 13 } pskMap OBJECT IDENTIFIER ::= { security 7 } pskMapTable OBJECT-TYPE SYNTAX SEQUENCE OF PskMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { pskMap 1 } pskMapEntry OBJECT-TYPE SYNTAX PskMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of pskMapTable" INDEX { pskMapPskIdentity } ::= { pskMapTable 1 } PskMapEntry ::= SEQUENCE { pskMapPskIdentity OCTET STRING, pskMapKey IetfYangTypesHexString, pskMapPskStatus INTEGER, pskMapPskInfo OCTET STRING, pskMapWarningTimer Unsigned32, pskMapCriticalTimer Unsigned32, pskMapTrafficOffTimer Unsigned32, pskMapEffectiveTimestamp IetfYangTypesDateAndTime } pskMapPskIdentity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The PSK identity encoded as a UTF-8 string. For details how certain common PSK identity formats can be encoded in UTF-8, see section 5.1. of RFC 4279. " ::= { pskMapEntry 1 } pskMapKey OBJECT-TYPE SYNTAX IetfYangTypesHexString MAX-ACCESS read-only STATUS current DESCRIPTION "The key associated with the PSK identity " ::= { pskMapEntry 2 } pskMapPskStatus OBJECT-TYPE SYNTAX INTEGER { init (1), sync (2), fail (3), authenticate (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the psk-map. psk-map can be updated only if psk-status is in init or sync status; the previous psk-map updating can be cancelled only if psk-satus is updating; psk-map cannot be updated and previous psk-map updating cannot be cancelled if psk-status is candidate-key-authenticate. default value :init" ::= { pskMapEntry 4 } pskMapPskInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The label of the psk-map. default value :" ::= { pskMapEntry 5 } pskMapWarningTimer OBJECT-TYPE SYNTAX Unsigned32 (1..240) MAX-ACCESS read-only STATUS current DESCRIPTION "Warning Time before psk-map updating completes. UNITS:minutes default value :5" ::= { pskMapEntry 6 } pskMapCriticalTimer OBJECT-TYPE SYNTAX Unsigned32 (1..480) MAX-ACCESS read-only STATUS current DESCRIPTION "Critical time before psk-map updating completes. UNITS:minutes default value :30" ::= { pskMapEntry 7 } pskMapTrafficOffTimer OBJECT-TYPE SYNTAX Unsigned32 (1..1440) MAX-ACCESS read-only STATUS current DESCRIPTION "Traffic off time before psk-map updating completes. UNITS:minutes default value :1440" ::= { pskMapEntry 8 } pskMapEffectiveTimestamp OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Time of new psk starts to take effect. " ::= { pskMapEntry 9 } key OBJECT IDENTIFIER ::= { security 9 } keyTable OBJECT-TYPE SYNTAX SEQUENCE OF KeyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A key maintained by the keystore." ::= { key 1 } keyEntry OBJECT-TYPE SYNTAX KeyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of keyTable" INDEX { keyName } ::= { keyTable 1 } KeyEntry ::= SEQUENCE { keyName OCTET STRING, keyAlgorithmIdentifier INTEGER, keyPublicKey OCTET STRING } keyName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "An arbitrary name for the key. " ::= { keyEntry 1 } keyAlgorithmIdentifier OBJECT-TYPE SYNTAX INTEGER { rsa1024 (1), rsa2048 (2), rsa3072 (3), rsa4096 (4), rsa7680 (5), rsa15360 (6), secp192r1 (7), secp256r1 (8), secp384r1 (9), secp521r1 (10) } MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies which algorithm is to be used with the key. This value determines how the 'private-key' and 'public-key' fields are interpreted. " ::= { keyEntry 2 } keyPublicKey OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3000)) MAX-ACCESS read-only STATUS current DESCRIPTION "A binary string that contains the value of the public key. The interpretation of the content is defined in the registration of the key algorithm. For example, a DSA key is an INTEGER, an RSA key is represented as RSAPublicKey as defined in [RFC3447], and an Elliptic Curve Cryptography (ECC) key is represented using the 'publicKey' described in [RFC5915] " ::= { keyEntry 3 } certificate OBJECT IDENTIFIER ::= { security 10 } certificateTable OBJECT-TYPE SYNTAX SEQUENCE OF CertificateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A certificate for this private key." ::= { certificate 1 } certificateEntry OBJECT-TYPE SYNTAX CertificateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of certificateTable" INDEX { keyName,certificateName } ::= { certificateTable 1 } CertificateEntry ::= SEQUENCE { certificateName OCTET STRING, certificateVersion INTEGER, certificateSerialNumber OCTET STRING, certificateSignatureAlgorithm OCTET STRING, certificateIssuer OCTET STRING, certificateValidFrom OCTET STRING, certificateValidTo OCTET STRING, certificateSubject OCTET STRING, certificatePublicKeyAlgorithm OCTET STRING, certificateSubjectAltName OCTET STRING } certificateName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "An arbitrary name for the certificate. The name must be a unique across all keys, not just within this key. " ::= { certificateEntry 1 } certificateVersion OBJECT-TYPE SYNTAX INTEGER { x509v1 (1), x509v2 (2), x509v3 (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "version of the certificate. default value :x509v1" ::= { certificateEntry 2 } certificateSerialNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "serial number of the certificate. " ::= { certificateEntry 3 } certificateSignatureAlgorithm OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "signature algorithm of the certificate. " ::= { certificateEntry 4 } certificateIssuer OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "issuer of the certificate. " ::= { certificateEntry 5 } certificateValidFrom OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "valid-from date and time of the certificate. " ::= { certificateEntry 6 } certificateValidTo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "valid-to date and time of the certificate. " ::= { certificateEntry 7 } certificateSubject OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "subject of the certificate. " ::= { certificateEntry 8 } certificatePublicKeyAlgorithm OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "public-key-algorithm of the certificate. " ::= { certificateEntry 9 } certificateSubjectAltName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..2000)) MAX-ACCESS read-only STATUS current DESCRIPTION "Subject Alternative Names of the certificate. " ::= { certificateEntry 10 } trustedCertificateGroup OBJECT IDENTIFIER ::= { security 11 } trustedCertificateGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF TrustedCertificateGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of trusted certificates. These certificates can be used by a server to authenticate clients, or by clients to authenticate servers. The certificates may be endpoint specific or for certificate authorities, to authenticate many clients at once. Each list of certificates SHOULD be specific to a purpose, as the list as a whole may be referenced by other modules. For instance, a NETCONF server model might point to a list of certificates to use when authenticating client certificates." ::= { trustedCertificateGroup 1 } trustedCertificateGroupEntry OBJECT-TYPE SYNTAX TrustedCertificateGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of trustedCertificateGroupTable" INDEX { trustedCertificateGroupName } ::= { trustedCertificateGroupTable 1 } TrustedCertificateGroupEntry ::= SEQUENCE { trustedCertificateGroupName OCTET STRING } trustedCertificateGroupName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "An arbitrary name for this list of trusted certificates. " ::= { trustedCertificateGroupEntry 1 } trustedCertificate OBJECT IDENTIFIER ::= { security 12 } trustedCertificateTable OBJECT-TYPE SYNTAX SEQUENCE OF TrustedCertificateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A trusted certificate for a specific use. Note, this 'certificate' is a list in order to encode any associated intermediate certificates." ::= { trustedCertificate 1 } trustedCertificateEntry OBJECT-TYPE SYNTAX TrustedCertificateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of trustedCertificateTable" INDEX { trustedCertificateGroupName,trustedCertificateName } ::= { trustedCertificateTable 1 } TrustedCertificateEntry ::= SEQUENCE { trustedCertificateName OCTET STRING, trustedCertificateVersion INTEGER, trustedCertificateSerialNumber OCTET STRING, trustedCertificateSignatureAlgorithm OCTET STRING, trustedCertificateIssuer OCTET STRING, trustedCertificateValidFrom OCTET STRING, trustedCertificateValidTo OCTET STRING, trustedCertificateSubject OCTET STRING, trustedCertificatePublicKeyAlgorithm OCTET STRING, trustedCertificateSubjectAltName OCTET STRING } trustedCertificateName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "An arbitrary name for this trusted certificate. Must be unique across all lists of trusted certificates (not just this list) so that a leafref to it from another module can resolve to unique values. " ::= { trustedCertificateEntry 1 } trustedCertificateVersion OBJECT-TYPE SYNTAX INTEGER { x509v1 (1), x509v2 (2), x509v3 (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "version of the certificate. default value :x509v1" ::= { trustedCertificateEntry 2 } trustedCertificateSerialNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "serial number of the certificate. " ::= { trustedCertificateEntry 3 } trustedCertificateSignatureAlgorithm OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "signature algorithm of the certificate. " ::= { trustedCertificateEntry 4 } trustedCertificateIssuer OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "issuer of the certificate. " ::= { trustedCertificateEntry 5 } trustedCertificateValidFrom OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "valid-from date and time of the certificate. " ::= { trustedCertificateEntry 6 } trustedCertificateValidTo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "valid-to date and time of the certificate. " ::= { trustedCertificateEntry 7 } trustedCertificateSubject OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "subject of the certificate. " ::= { trustedCertificateEntry 8 } trustedCertificatePublicKeyAlgorithm OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "public-key-algorithm of the certificate. " ::= { trustedCertificateEntry 9 } trustedCertificateSubjectAltName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..2000)) MAX-ACCESS read-only STATUS current DESCRIPTION "Subject Alternative Names of the certificate. " ::= { trustedCertificateEntry 10 } authorizedKey OBJECT IDENTIFIER ::= { security 14 } authorizedKeyTable OBJECT-TYPE SYNTAX SEQUENCE OF AuthorizedKeyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { authorizedKey 1 } authorizedKeyEntry OBJECT-TYPE SYNTAX AuthorizedKeyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of authorizedKeyTable" INDEX { userName,authorizedKeyName } ::= { authorizedKeyTable 1 } AuthorizedKeyEntry ::= SEQUENCE { authorizedKeyName OCTET STRING, authorizedKeyPublicKey OCTET STRING } authorizedKeyName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "name of authorized key. " ::= { authorizedKeyEntry 1 } authorizedKeyPublicKey OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..3000)) MAX-ACCESS read-only STATUS current DESCRIPTION "one of the authorized public keys of the user. " ::= { authorizedKeyEntry 2 } certificateChain OBJECT IDENTIFIER ::= { security 15 } certificateChainTable OBJECT-TYPE SYNTAX SEQUENCE OF CertificateChainEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "certificate chain." ::= { certificateChain 1 } certificateChainEntry OBJECT-TYPE SYNTAX CertificateChainEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of certificateChainTable" INDEX { keyName,certificateName,certificateChainLevel } ::= { certificateChainTable 1 } CertificateChainEntry ::= SEQUENCE { certificateChainLevel OCTET STRING, certificateChainVersion INTEGER, certificateChainSerialNumber OCTET STRING, certificateChainSignatureAlgorithm OCTET STRING, certificateChainIssuer OCTET STRING, certificateChainValidFrom OCTET STRING, certificateChainValidTo OCTET STRING, certificateChainSubject OCTET STRING, certificateChainPublicKeyAlgorithm OCTET STRING, certificateChainSubjectAltName OCTET STRING } certificateChainLevel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "certificate chain level. " ::= { certificateChainEntry 1 } certificateChainVersion OBJECT-TYPE SYNTAX INTEGER { x509v1 (1), x509v2 (2), x509v3 (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "version of the certificate. default value :x509v1" ::= { certificateChainEntry 2 } certificateChainSerialNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "serial number of the certificate. " ::= { certificateChainEntry 3 } certificateChainSignatureAlgorithm OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "signature algorithm of the certificate. " ::= { certificateChainEntry 4 } certificateChainIssuer OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "issuer of the certificate. " ::= { certificateChainEntry 5 } certificateChainValidFrom OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "valid-from date and time of the certificate. " ::= { certificateChainEntry 6 } certificateChainValidTo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "valid-to date and time of the certificate. " ::= { certificateChainEntry 7 } certificateChainSubject OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "subject of the certificate. " ::= { certificateChainEntry 8 } certificateChainPublicKeyAlgorithm OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "public-key-algorithm of the certificate. " ::= { certificateChainEntry 9 } certificateChainSubjectAltName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..2000)) MAX-ACCESS read-only STATUS current DESCRIPTION "Subject Alternative Names of the certificate. " ::= { certificateChainEntry 10 } nbi OBJECT IDENTIFIER ::= { groove 8 } snmp OBJECT IDENTIFIER ::= { nbi 1 } snmpv3 OBJECT IDENTIFIER ::= { snmp 1 } snmpv3Table OBJECT-TYPE SYNTAX SEQUENCE OF Snmpv3Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "SNMPv3 configuration for user" ::= { snmpv3 1 } snmpv3Entry OBJECT-TYPE SYNTAX Snmpv3Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of snmpv3Table" INDEX { userName } ::= { snmpv3Table 1 } Snmpv3Entry ::= SEQUENCE { snmpv3UserSecLevel INTEGER, snmpv3AuthProtocol INTEGER, snmpv3AuthPassphrase OCTET STRING, snmpv3PrivProtocol INTEGER, snmpv3PrivPassphrase OCTET STRING } snmpv3UserSecLevel OBJECT-TYPE SYNTAX INTEGER { authPriv (1), authNoPriv (2), noAuthNoPriv (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the SNMPv3 user security level. default value :no-auth-no-priv" ::= { snmpv3Entry 1 } snmpv3AuthProtocol OBJECT-TYPE SYNTAX INTEGER { md5 (1), sha (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the authentication protocol that the SNMPv3 user being created will use. Conditions:(../user-sec-level = 'auth-priv') or (../user-sec-level = 'auth-no-priv') default value :SHA" ::= { snmpv3Entry 2 } snmpv3AuthPassphrase OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0|8..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the SNMPv3 authentication pass phrase. Conditions:(../user-sec-level = 'auth-priv') or (../user-sec-level = 'auth-no-priv') " ::= { snmpv3Entry 3 } snmpv3PrivProtocol OBJECT-TYPE SYNTAX INTEGER { des (1), aes (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the privacy protocol that the SNMPv3 user being created will use. Conditions:../user-sec-level = 'auth-priv' default value :AES" ::= { snmpv3Entry 4 } snmpv3PrivPassphrase OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0|8..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies the SNMPv3 privacy pass phrase. Conditions:../user-sec-level = 'auth-priv' " ::= { snmpv3Entry 5 } snmpInfo OBJECT IDENTIFIER ::= { snmp 2 } snmpEngineId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "snmp EngineID of the NE. The EngineID will follow the EngineID format 3 defined in RFC3411. The MAC address in the Engine ID will be the first MAC address of the MAC addresses Pool of the NE. " ::= { snmpInfo 1 } snmpEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "User configurable switch to enable or disable global SNMP access default value :true" ::= { snmpInfo 2 } snmpContactInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..512)) MAX-ACCESS read-only STATUS current DESCRIPTION "SNMP contact info of the NE. Default value is device info. Allow user defined value default value :https://www.infinera.com" ::= { snmpInfo 3 } snmpCommunity OBJECT IDENTIFIER ::= { snmp 3 } snmpCommunityTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpCommunityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of SNMP Community Strings. Please note that the trap-community-string is located in the snmp-target MO." ::= { snmpCommunity 1 } snmpCommunityEntry OBJECT-TYPE SYNTAX SnmpCommunityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of snmpCommunityTable" INDEX { snmpCommunityCommunityString } ::= { snmpCommunityTable 1 } SnmpCommunityEntry ::= SEQUENCE { snmpCommunityCommunityString CoriantTypesSnmpString, snmpCommunityCommunityStringAccess INTEGER } snmpCommunityCommunityString OBJECT-TYPE SYNTAX CoriantTypesSnmpString MAX-ACCESS read-only STATUS current DESCRIPTION "Community String. " ::= { snmpCommunityEntry 1 } snmpCommunityCommunityStringAccess OBJECT-TYPE SYNTAX INTEGER { readOnly (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "snmp access right of this community string. default value :read-only" ::= { snmpCommunityEntry 2 } snmpTarget OBJECT IDENTIFIER ::= { snmp 4 } snmpTargetTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpTargetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of SNMP targets (trap listeners)" ::= { snmpTarget 1 } snmpTargetEntry OBJECT-TYPE SYNTAX SnmpTargetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of snmpTargetTable" INDEX { snmpTargetTargetName } ::= { snmpTargetTable 1 } SnmpTargetEntry ::= SEQUENCE { snmpTargetSnmpVersion INTEGER, snmpTargetSnmpv3User RowPointer, snmpTargetTargetName OCTET STRING, snmpTargetTargetIp IetfInetTypesIpAddress, snmpTargetTargetPort IetfInetTypesPortNumber, snmpTargetTargetTransport INTEGER, snmpTargetTrapCommunityString CoriantTypesSnmpString } snmpTargetSnmpVersion OBJECT-TYPE SYNTAX INTEGER { v2c (2), v3 (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "snmp version. default value :v2c" ::= { snmpTargetEntry 1 } snmpTargetSnmpv3User OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate the snmpv3 user. Conditions:../snmp-version = 'v3' " ::= { snmpTargetEntry 2 } snmpTargetTargetName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the SNMP target " ::= { snmpTargetEntry 3 } snmpTargetTargetIp OBJECT-TYPE SYNTAX IetfInetTypesIpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address of the SNMP target " ::= { snmpTargetEntry 4 } snmpTargetTargetPort OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "UDP port number. default value :162" ::= { snmpTargetEntry 5 } snmpTargetTargetTransport OBJECT-TYPE SYNTAX INTEGER { udp (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of transport for the SNMP target default value :udp" ::= { snmpTargetEntry 6 } snmpTargetTrapCommunityString OBJECT-TYPE SYNTAX CoriantTypesSnmpString MAX-ACCESS read-only STATUS current DESCRIPTION "Community string used for SNMP traps Conditions:../snmp-version = 'v2c' default value :groove" ::= { snmpTargetEntry 7 } cli OBJECT IDENTIFIER ::= { nbi 2 } cliConfig OBJECT IDENTIFIER ::= { cli 1 } cliConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF CliConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { cliConfig 1 } cliConfigEntry OBJECT-TYPE SYNTAX CliConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of cliConfigTable" INDEX { sessionId } ::= { cliConfigTable 1 } CliConfigEntry ::= SEQUENCE { cliConfigCliLines Unsigned32, cliConfigCliColumns Unsigned32, cliConfigMaxHistorySize Unsigned32, cliConfigInteractiveMode CoriantTypesEnableSwitch } cliConfigCliLines OBJECT-TYPE SYNTAX Unsigned32 (10..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of rows to be used for display. This value is automatically discovered when possible default value :40" ::= { cliConfigEntry 1 } cliConfigCliColumns OBJECT-TYPE SYNTAX Unsigned32 (80..4000) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of columns to be used for display. This value is automatically discovered when possible default value :140" ::= { cliConfigEntry 2 } cliConfigMaxHistorySize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Command history maximum size for the current session default value :500" ::= { cliConfigEntry 3 } cliConfigInteractiveMode OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION " This determines if the CLI shall issue interactive prompt (e.g. for prompting additional information, or for confirmation of user initiated actions). Enabled = CLI will prompt user (default) Disabled = CLI will suppress any prompt to the user This parameter is set per CLI session and is not persistent. default value :enabled" ::= { cliConfigEntry 4 } restconf OBJECT IDENTIFIER ::= { nbi 3 } restconfRestHttpSupport OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Defines if the HTTP port (8080) is enabled for RESTCONF default value :disabled" ::= { restconf 1 } restconfRestHttpsSupport OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Defines if the HTTPS port (8181) is enabled for RESTCONF default value :enabled" ::= { restconf 2 } restconfRestSessionTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..300) MAX-ACCESS read-only STATUS current DESCRIPTION "Timeout of a cookie based RESTCONF session. The cookie expiration date is reset every time there is activity on the session. UNITS:minutes default value :5" ::= { restconf 3 } restconfEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "User configurable switch to enable or disable RESTCONF access default value :true" ::= { restconf 4 } cliAlias OBJECT IDENTIFIER ::= { nbi 4 } cliAliasTable OBJECT-TYPE SYNTAX SEQUENCE OF CliAliasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of aliases used in CLI. Can only be accessed via 'alias/unalias' CLI commands." ::= { cliAlias 1 } cliAliasEntry OBJECT-TYPE SYNTAX CliAliasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of cliAliasTable" INDEX { cliAliasName } ::= { cliAliasTable 1 } CliAliasEntry ::= SEQUENCE { cliAliasName OCTET STRING, cliAliasValue OCTET STRING } cliAliasName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the alias " ::= { cliAliasEntry 1 } cliAliasValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..1024)) MAX-ACCESS read-only STATUS current DESCRIPTION "Value of the alias " ::= { cliAliasEntry 2 } cliScript OBJECT IDENTIFIER ::= { nbi 5 } cliScriptTable OBJECT-TYPE SYNTAX SEQUENCE OF CliScriptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of available CLI scripts. Scripts can be executed with the 'run' command" ::= { cliScript 1 } cliScriptEntry OBJECT-TYPE SYNTAX CliScriptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of cliScriptTable" INDEX { cliScriptScriptName } ::= { cliScriptTable 1 } CliScriptEntry ::= SEQUENCE { cliScriptScriptName OCTET STRING, cliScriptDescription OCTET STRING } cliScriptScriptName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "File name of the CLI script " ::= { cliScriptEntry 1 } cliScriptDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "Description of the CLI script " ::= { cliScriptEntry 2 } netconf OBJECT IDENTIFIER ::= { nbi 6 } netconfAnnotateCliName OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "If enabled, annotates NETCONF XML output with cli names for traceability. default value :disabled" ::= { netconf 1 } netconfEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "User configurable switch to enable or disable NETCONF access default value :true" ::= { netconf 2 } grpc OBJECT IDENTIFIER ::= { nbi 7 } grpcEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "User configurable switch to enable or disable gRPC/gNMI access default value :true" ::= { grpc 1 } filesw OBJECT IDENTIFIER ::= { groove 9 } softwareload OBJECT IDENTIFIER ::= { filesw 2 } softwareloadTable OBJECT-TYPE SYNTAX SEQUENCE OF SoftwareloadEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The list of the software loads in the system." ::= { softwareload 1 } softwareloadEntry OBJECT-TYPE SYNTAX SoftwareloadEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of softwareloadTable" INDEX { softwareloadSwloadId } ::= { softwareloadTable 1 } SoftwareloadEntry ::= SEQUENCE { softwareloadSwloadId Unsigned32, softwareloadSwloadState INTEGER, softwareloadSwloadVersion CoriantFileSwTypesSwVersion, softwareloadSwloadVendor CoriantFileSwTypesSwloadVendor, softwareloadSwloadProduct CoriantFileSwTypesSwloadProduct, softwareloadSwloadLabel OCTET STRING } softwareloadSwloadId OBJECT-TYPE SYNTAX Unsigned32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION " software load identifier which is uniquely identify specific software load. " ::= { softwareloadEntry 1 } softwareloadSwloadState OBJECT-TYPE SYNTAX INTEGER { active (1), inactive (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the state of the software load. " ::= { softwareloadEntry 2 } softwareloadSwloadVersion OBJECT-TYPE SYNTAX CoriantFileSwTypesSwVersion MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the software version of the software load. " ::= { softwareloadEntry 3 } softwareloadSwloadVendor OBJECT-TYPE SYNTAX CoriantFileSwTypesSwloadVendor MAX-ACCESS read-only STATUS current DESCRIPTION " Vendor information of the software load. " ::= { softwareloadEntry 4 } softwareloadSwloadProduct OBJECT-TYPE SYNTAX CoriantFileSwTypesSwloadProduct MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the network element family this software belongs to. " ::= { softwareloadEntry 5 } softwareloadSwloadLabel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..1024)) MAX-ACCESS read-only STATUS current DESCRIPTION " The label of the software load including summary information. " ::= { softwareloadEntry 6 } database OBJECT IDENTIFIER ::= { filesw 3 } databaseTable OBJECT-TYPE SYNTAX SEQUENCE OF DatabaseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The list of the databases in the system." ::= { database 1 } databaseEntry OBJECT-TYPE SYNTAX DatabaseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of databaseTable" INDEX { softwareloadSwloadId,databaseId } ::= { databaseTable 1 } DatabaseEntry ::= SEQUENCE { databaseId Unsigned32, databaseState INTEGER, databaseVersion CoriantFileSwTypesSwVersion, databaseVendor CoriantFileSwTypesSwloadVendor, databaseProduct CoriantFileSwTypesSwloadProduct, databaseBackupTime OCTET STRING } databaseId OBJECT-TYPE SYNTAX Unsigned32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION " database identifier which is uniquely identify specific database. " ::= { databaseEntry 1 } databaseState OBJECT-TYPE SYNTAX INTEGER { active (1), inactive (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the state of the database. " ::= { databaseEntry 2 } databaseVersion OBJECT-TYPE SYNTAX CoriantFileSwTypesSwVersion MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the database version. " ::= { databaseEntry 3 } databaseVendor OBJECT-TYPE SYNTAX CoriantFileSwTypesSwloadVendor MAX-ACCESS read-only STATUS current DESCRIPTION " Vendor information of the database. " ::= { databaseEntry 4 } databaseProduct OBJECT-TYPE SYNTAX CoriantFileSwTypesSwloadProduct MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the network element family this database belongs to. " ::= { databaseEntry 5 } databaseBackupTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the database last backup time. default value :" ::= { databaseEntry 6 } fwVersionMap OBJECT IDENTIFIER ::= { filesw 4 } fwVersionMapTable OBJECT-TYPE SYNTAX SEQUENCE OF FwVersionMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The firmware information of the upgradable devices included in the software load." ::= { fwVersionMap 1 } fwVersionMapEntry OBJECT-TYPE SYNTAX FwVersionMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of fwVersionMapTable" INDEX { softwareloadSwloadId,fwVersionMapDeviceName } ::= { fwVersionMapTable 1 } FwVersionMapEntry ::= SEQUENCE { fwVersionMapDeviceName CoriantFileSwTypesDeviceName, fwVersionMapDeviceFwVersion CoriantFileSwTypesDeviceFwVersion } fwVersionMapDeviceName OBJECT-TYPE SYNTAX CoriantFileSwTypesDeviceName MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the name of the device. " ::= { fwVersionMapEntry 1 } fwVersionMapDeviceFwVersion OBJECT-TYPE SYNTAX CoriantFileSwTypesDeviceFwVersion MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the version of the firmware. " ::= { fwVersionMapEntry 2 } currentFwVersion OBJECT IDENTIFIER ::= { filesw 5 } currentFwVersionTable OBJECT-TYPE SYNTAX SEQUENCE OF CurrentFwVersionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The firmware information of the upgradable devices included in the software load." ::= { currentFwVersion 1 } currentFwVersionEntry OBJECT-TYPE SYNTAX CurrentFwVersionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of currentFwVersionTable" INDEX { currentFwVersionEquipmentEntity,currentFwVersionDeviceName } ::= { currentFwVersionTable 1 } CurrentFwVersionEntry ::= SEQUENCE { currentFwVersionEquipmentEntity RowPointer, currentFwVersionFwEquipmentType CoriantTypesEquipmentType, currentFwVersionDeviceName CoriantFileSwTypesDeviceName, currentFwVersionDeviceFwVersion CoriantFileSwTypesDeviceFwVersion, currentFwVersionFwState INTEGER, currentFwVersionSystemFwVersion CoriantFileSwTypesDeviceFwVersion } currentFwVersionEquipmentEntity OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the entity of the equipment carrying the device. " ::= { currentFwVersionEntry 1 } currentFwVersionFwEquipmentType OBJECT-TYPE SYNTAX CoriantTypesEquipmentType MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the type of the equipment carrying the device. " ::= { currentFwVersionEntry 2 } currentFwVersionDeviceName OBJECT-TYPE SYNTAX CoriantFileSwTypesDeviceName MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the name of the device. " ::= { currentFwVersionEntry 3 } currentFwVersionDeviceFwVersion OBJECT-TYPE SYNTAX CoriantFileSwTypesDeviceFwVersion MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the version of the firmware. " ::= { currentFwVersionEntry 4 } currentFwVersionFwState OBJECT-TYPE SYNTAX INTEGER { notAvailable (0), current (1), notCurrent (2) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates firmware state of the device. Current: indicates the loaded firmware is the version of current software load. Not-current: indicates the loaded firmware is not the version of current software load. default value :not-available" ::= { currentFwVersionEntry 5 } currentFwVersionSystemFwVersion OBJECT-TYPE SYNTAX CoriantFileSwTypesDeviceFwVersion MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the version of the firmware in system appication. " ::= { currentFwVersionEntry 6 } rollbackPoint OBJECT IDENTIFIER ::= { filesw 6 } rollbackPointTable OBJECT-TYPE SYNTAX SEQUENCE OF RollbackPointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents a rollback point stored in the system. A rollback point represents the system configuration of a specific point in time, that the user may create with the 'create-rollback-point' command, visualize with the 'diff' command' and rollback to with the 'rollback' command. The system is able to store up to 10 rollback-points, rolling over old instances as new ones are created. The incremental IDs of 1..10 are automatically generated by the system whenever the rollback-point is created. Rollback points can be deleted as any normal object. A special 'backup' rollback-point can also be created with ID 0; unlike normal rollback-points, this instance will be kept even after activation with the 'rollback' RPC." ::= { rollbackPoint 1 } rollbackPointEntry OBJECT-TYPE SYNTAX RollbackPointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of rollbackPointTable" INDEX { rollbackPointId } ::= { rollbackPointTable 1 } RollbackPointEntry ::= SEQUENCE { rollbackPointId Unsigned32, rollbackPointCreationTime IetfYangTypesDateAndTime, rollbackPointCreationTrigger CoriantTypesUserName, rollbackPointDescription OCTET STRING, rollbackPointType INTEGER } rollbackPointId OBJECT-TYPE SYNTAX Unsigned32 (0..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Integer ID of the rollback-point. Generated dynamically whenever a rollback-point is created, with range 1 to 100 " ::= { rollbackPointEntry 1 } rollbackPointCreationTime OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp when this rollback-point was created " ::= { rollbackPointEntry 2 } rollbackPointCreationTrigger OBJECT-TYPE SYNTAX CoriantTypesUserName MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the author user-name of this rollback-point " ::= { rollbackPointEntry 3 } rollbackPointDescription OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..200)) MAX-ACCESS read-only STATUS current DESCRIPTION "User defined description of this rollback-point " ::= { rollbackPointEntry 4 } rollbackPointType OBJECT-TYPE SYNTAX INTEGER { normal (1), backup (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the rollback-point default value :normal" ::= { rollbackPointEntry 5 } logServer OBJECT IDENTIFIER ::= { filesw 8 } logServerTable OBJECT-TYPE SYNTAX SEQUENCE OF LogServerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Grouping the configuration parameters for log forwarding." ::= { logServer 1 } logServerEntry OBJECT-TYPE SYNTAX LogServerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of logServerTable" INDEX { logServerName } ::= { logServerTable 1 } LogServerEntry ::= SEQUENCE { logServerName OCTET STRING, logServerIpAddress IetfInetTypesIpAddress, logServerTransport INTEGER, logServerPort IetfInetTypesPortNumber, logServerDestinationFacilityType CoriantTypesEnableSwitch, logServerDestinationFacility OCTET STRING } logServerName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name for the endpoint to forwarding logs to. " ::= { logServerEntry 1 } logServerIpAddress OBJECT-TYPE SYNTAX IetfInetTypesIpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The leaf uniquely specifies the ipv4 address of the remote host. " ::= { logServerEntry 2 } logServerTransport OBJECT-TYPE SYNTAX INTEGER { tcp (1), udp (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "It is the transport protocol used when forwarding logs. default value :udp" ::= { logServerEntry 3 } logServerPort OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "This leaf specifies the port number used to deliver messages to the remote server. default value :514" ::= { logServerEntry 4 } logServerDestinationFacilityType OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION "Switching of the function destination-facility default value :disabled" ::= { logServerEntry 5 } logServerDestinationFacility OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This leaf specifies the facility used in messages delivered to the remote server. default value :23" ::= { logServerEntry 6 } logFacility OBJECT IDENTIFIER ::= { filesw 10 } logFacilityTable OBJECT-TYPE SYNTAX SEQUENCE OF LogFacilityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { logFacility 1 } logFacilityEntry OBJECT-TYPE SYNTAX LogFacilityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of logFacilityTable" INDEX { logServerName,logFacilityLogSelectorFacility } ::= { logFacilityTable 1 } LogFacilityEntry ::= SEQUENCE { logFacilityLogSelectorFacility INTEGER, logFacilityLogSelectorSeverity INTEGER, logFacilityCompareOp INTEGER, logFacilityEnabled TruthValue } logFacilityLogSelectorFacility OBJECT-TYPE SYNTAX INTEGER { security (1), alarm (2), event (3), configuration (4), cryptoConfiguration (5), cryptoSecurity (6), cryptoEvent (7), cryptoAlarm (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The leaf uniquely identifies a syslog facility for forwarding. " ::= { logFacilityEntry 1 } logFacilityLogSelectorSeverity OBJECT-TYPE SYNTAX INTEGER { emergency (0), alert (1), critical (2), error (3), warning (4), notice (5), informational (6), debug (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The system log selected severity level for forwarding default value :debug" ::= { logFacilityEntry 2 } logFacilityCompareOp OBJECT-TYPE SYNTAX INTEGER { equalsOrHigher (1), equals (2), notEquals (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This leaf describes the option to specify how the severity comparison is performed. default value :equals-or-higher" ::= { logFacilityEntry 3 } logFacilityEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The current operational state of the facility. default value :true" ::= { logFacilityEntry 4 } timeManager OBJECT IDENTIFIER ::= { groove 10 } timeManagerInfo OBJECT IDENTIFIER ::= { timeManager 1 } timeManagerTimezone OBJECT-TYPE SYNTAX INTEGER { internationalDateLineWestGmt1200 (1), midwayIslandSamoaGmt1100 (2), hawaiiGmt1000 (3), alaskaGmt0900 (4), pacificTimeUsAndCanadaGmt0800 (5), arizonaGmt0700 (6), mountainTimeUsAndCanadaGmt0700 (7), centralamericaGmt0600 (8), centralTimeUsAndCanadaGmt0600 (9), mexicoCityTegucigalpaGmt0600 (10), saskatchewanGmt0600 (11), bagotaLimaQuitoGmt0500 (12), easternTimeUsAndCanadaGmt0500 (13), indianaEastGmt0500 (14), caracasLaPazGmt0430 (15), atlanticTimeCanadaGmt0400 (16), santiagoGmt0400 (17), newfoundlandGmt0330 (18), brasiliaGmt0300 (19), buenosAiresGeorgetownGmt0300 (20), greenlandGmt0300 (21), midAtlanticGmt0200 (22), azoresGmt0100 (23), capeVerdeIsGmt0100 (24), casablancaMonroviaGmt (25), greenwichMeanTimeDublinEdinburghLisbonLondonGmt (26), amsterdamCopenhagenMadridParisvilniusGmtplus0100 (27), belgradeSarajevoSkopjeSofijaZargrebGmtplus0100 (28), bratislavaBudapestLjublijanaPragueWasawGmtplus0100 (29), brusselsBerlinBernRomeStockholmViennaGmtplus0100 (30), westCentralAfricaGmtplus0100 (31), athensIstanbulMinskGmtplus0200 (32), bucharestGmtplus0200 (33), cairoGmtplus0200 (34), hararePretoriaGmtplus0200 (35), helsinkiRigaTallinnGmtplus0200 (36), jerusalemGmtplus0200 (37), israelGmtplus0200 (38), baghdadGmtplus0300 (39), kuwaitRiyadhGmtplus0300 (40), moscowStPetersburgVolgogradGmtplus0300 (41), nairobiGmtplus0300 (42), tehranGmtplus0330 (43), abuDhabiMuscatGmtplus0400 (44), bakuGmtplus0400 (45), tbilisiGmtplus0400 (46), kabulGmtplus0430 (47), ekaterinburgGmtplus0500 (48), islamabadKarachiTashkentGmtplus0500 (49), mumbaiCalcuttaChennaiNewDelhiGmtplus0530 (50), colomboGmtplus0530 (51), kathmanduGmtplus0545 (52), dhakaGmtplus0600 (53), almatyGmtplus0600 (54), rangoonGmtplus0630 (55), bangkokHanoiJakartaGmtplus0700 (56), beijingChongqingHongKongUrumqiGmtplus0800 (57), perthGmtplus0800 (58), singaporeKualaLumpurGmtplus0800 (59), taipeiGmtplus0800 (60), osakaSapporoTokyoGmtplus0900 (61), seoulGmtplus0900 (62), yakutskGmtplus0900 (63), adelaideGmtplus0930 (64), darwinGmtplus0930 (65), brisbaneGmtplus1000 (66), canberraMelbourneSydneyGmtplus1000 (67), guamPortMoresbyGmtplus1000 (68), hobartGmtplus1000 (69), vladivostokGmtplus1000 (70), magadanSolomonIsNewCaledoniaGmtplus1100 (71), aucklandWellingtonGmtplus1200 (72), fijiKamchatkaMarshallIsGmtplus1200 (73), eniwetokKwajaleinGmtplus1200 (74), nukuAlofaGmtplus1300 (75), kiritimatiGmtplus1400 (76), universalTimeCoordinated (77) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Name of the Time Zone of this NE. default value :Greenwich_Mean_Time:Dublin-Edinburgh-Lisbon-London[GMT]" ::= { timeManagerInfo 1 } timeManagerCurrentTime OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current Date and Time of this NE. " ::= { timeManagerInfo 2 } timeManagerLastStartTime OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate the time of last system boot. " ::= { timeManagerInfo 3 } timeManagerUpTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate how long the system has been running. " ::= { timeManagerInfo 4 } timeManagerTimeSourceState OBJECT-TYPE SYNTAX INTEGER { external (1), freerun (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the state of the time source. " ::= { timeManagerInfo 5 } ntp OBJECT IDENTIFIER ::= { timeManager 2 } ntpEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if NTP is enabled. default value :true" ::= { ntp 1 } ntpCurrentTimeSource OBJECT-TYPE SYNTAX IetfInetTypesIpAddressNoZone MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current time source. default value :0.0.0.0" ::= { ntp 2 } ntpAssociation OBJECT IDENTIFIER ::= { timeManager 3 } ntpAssociationTable OBJECT-TYPE SYNTAX SEQUENCE OF NtpAssociationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { ntpAssociation 1 } ntpAssociationEntry OBJECT-TYPE SYNTAX NtpAssociationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ntpAssociationTable" INDEX { ntpAssociationSource } ::= { ntpAssociationTable 1 } NtpAssociationEntry ::= SEQUENCE { ntpAssociationSource IetfInetTypesIpAddressNoZone, ntpAssociationType INTEGER, ntpAssociationPreferredNtpAssociation TruthValue, ntpAssociationNtpAdminState INTEGER } ntpAssociationSource OBJECT-TYPE SYNTAX IetfInetTypesIpAddressNoZone (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ntp-association-source. " ::= { ntpAssociationEntry 1 } ntpAssociationType OBJECT-TYPE SYNTAX INTEGER { ntpServer (1), ntpPeer (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ntp association type. default value :ntp-server" ::= { ntpAssociationEntry 2 } ntpAssociationPreferredNtpAssociation OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if this is preferred. " ::= { ntpAssociationEntry 3 } ntpAssociationNtpAdminState OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The administrative state specifies the permission to use or prohibition against using the resource. default value :up" ::= { ntpAssociationEntry 4 } ntpAssociationStatus OBJECT IDENTIFIER ::= { timeManager 4 } ntpAssociationStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF NtpAssociationStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { ntpAssociationStatus 1 } ntpAssociationStatusEntry OBJECT-TYPE SYNTAX NtpAssociationStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ntpAssociationStatusTable" INDEX { ntpAssociationSource } ::= { ntpAssociationStatusTable 1 } NtpAssociationStatusEntry ::= SEQUENCE { ntpAssociationStatusNtpAssociationRefid OCTET STRING, ntpAssociationStatusNtpStratum Unsigned32, ntpAssociationStatusNtpPollingInterval Unsigned32, ntpAssociationStatusNtpPrecision OCTET STRING, ntpAssociationStatusNtpAssociationOffset OCTET STRING, ntpAssociationStatusNtpAssociationReach Unsigned32, ntpAssociationStatusNtpAssociationDelay OCTET STRING, ntpAssociationStatusNtpAssociationDispersion OCTET STRING } ntpAssociationStatusNtpAssociationRefid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "Reference clock type or address for the peer. " ::= { ntpAssociationStatusEntry 1 } ntpAssociationStatusNtpStratum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the stratum of local clock. A value of 0, indicates that Stratum in Unspecified. " ::= { ntpAssociationStatusEntry 2 } ntpAssociationStatusNtpPollingInterval OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "NTP polling interval. This is an integer number indicating the HOST polling interval between transmitted messages, in seconds. UNITS:seconds " ::= { ntpAssociationStatusEntry 3 } ntpAssociationStatusNtpPrecision OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is an unsigned floating-point number indicating the precision of the various clocks, in milliseconds. UNITS:milliseconds " ::= { ntpAssociationStatusEntry 4 } ntpAssociationStatusNtpAssociationOffset OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the offset between the local clock and the superior reference clock. UNITS:milliseconds " ::= { ntpAssociationStatusEntry 5 } ntpAssociationStatusNtpAssociationReach OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the reachability of the configured server or peer. " ::= { ntpAssociationStatusEntry 6 } ntpAssociationStatusNtpAssociationDelay OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the delay between the local clock and the superior reference clock, in milliseconds. UNITS:milliseconds " ::= { ntpAssociationStatusEntry 7 } ntpAssociationStatusNtpAssociationDispersion OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the dispersion between the local clock and the peer clock, in milliseconds. UNITS:milliseconds " ::= { ntpAssociationStatusEntry 8 } ztc OBJECT IDENTIFIER ::= { groove 11 } ztcInfo OBJECT IDENTIFIER ::= { ztc 1 } ztcEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "enable/disable Zero Touch commissioning. default value :true" ::= { ztcInfo 1 } ztcStatus OBJECT-TYPE SYNTAX INTEGER { disabled (0), ready (1), ongoing (2), failed (3), done (4), incomplete (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the ZTC process status: disabled - ZTC will not be attempted because it was disabled via configuration ready - ZTC will be attempted when able to communicate with external ZTC server ongoing - ZTC is ongoing failed - some problems occurred during ZTC done - ZTC completed successfully incomplete - ZTC incomplete. default value :ready" ::= { ztcInfo 2 } ztcProxy OBJECT-TYPE SYNTAX CoriantTypesEnableSwitch MAX-ACCESS read-only STATUS current DESCRIPTION " The attribute will enable/disable the ztc proxy function for the subtending NEs. default value :enabled" ::= { ztcInfo 3 } ztcDhcpServer OBJECT-TYPE SYNTAX IetfInetTypesIpv4Address MAX-ACCESS read-only STATUS current DESCRIPTION " The IPv4 address of the DHCP server for the DHCP relay agent when the ztc-proxy is enabled. " ::= { ztcInfo 4 } common OBJECT IDENTIFIER ::= { groove 13 } bitErrorRatePreFec OBJECT IDENTIFIER ::= { common 1 } bitErrorRatePreFecTable OBJECT-TYPE SYNTAX SEQUENCE OF BitErrorRatePreFecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for bit error rate before fec, corresponding to pm parameter BER-FEC" ::= { bitErrorRatePreFec 1 } bitErrorRatePreFecEntry OBJECT-TYPE SYNTAX BitErrorRatePreFecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of bitErrorRatePreFecTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { bitErrorRatePreFecTable 1 } BitErrorRatePreFecEntry ::= SEQUENCE { bitErrorRatePreFecInstant OCTET STRING, bitErrorRatePreFecAvg OCTET STRING, bitErrorRatePreFecMin OCTET STRING, bitErrorRatePreFecMax OCTET STRING } bitErrorRatePreFecInstant OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter UNITS:bit-ratio " ::= { bitErrorRatePreFecEntry 1 } bitErrorRatePreFecAvg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter UNITS:bit-ratio " ::= { bitErrorRatePreFecEntry 2 } bitErrorRatePreFecMin OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter UNITS:bit-ratio " ::= { bitErrorRatePreFecEntry 3 } bitErrorRatePreFecMax OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter UNITS:bit-ratio " ::= { bitErrorRatePreFecEntry 4 } bitErrorRatePostFec OBJECT IDENTIFIER ::= { common 2 } bitErrorRatePostFecTable OBJECT-TYPE SYNTAX SEQUENCE OF BitErrorRatePostFecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for bit error rate post fec, corresponding to pm parameter BER-POST-FEC" ::= { bitErrorRatePostFec 1 } bitErrorRatePostFecEntry OBJECT-TYPE SYNTAX BitErrorRatePostFecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of bitErrorRatePostFecTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { bitErrorRatePostFecTable 1 } BitErrorRatePostFecEntry ::= SEQUENCE { bitErrorRatePostFecInstant OCTET STRING, bitErrorRatePostFecAvg OCTET STRING, bitErrorRatePostFecMin OCTET STRING, bitErrorRatePostFecMax OCTET STRING } bitErrorRatePostFecInstant OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter UNITS:bit-ratio " ::= { bitErrorRatePostFecEntry 1 } bitErrorRatePostFecAvg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter UNITS:bit-ratio " ::= { bitErrorRatePostFecEntry 2 } bitErrorRatePostFecMin OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter UNITS:bit-ratio " ::= { bitErrorRatePostFecEntry 3 } bitErrorRatePostFecMax OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter UNITS:bit-ratio " ::= { bitErrorRatePostFecEntry 4 } inUtilization OBJECT IDENTIFIER ::= { common 3 } inUtilizationTable OBJECT-TYPE SYNTAX SEQUENCE OF InUtilizationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for RX utilization, corresponding to pm parameter Utilization" ::= { inUtilization 1 } inUtilizationEntry OBJECT-TYPE SYNTAX InUtilizationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of inUtilizationTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { inUtilizationTable 1 } InUtilizationEntry ::= SEQUENCE { inUtilizationInstant CoriantTypesPercentage, inUtilizationAvg CoriantTypesPercentage, inUtilizationMin CoriantTypesPercentage, inUtilizationMax CoriantTypesPercentage } inUtilizationInstant OBJECT-TYPE SYNTAX CoriantTypesPercentage MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter " ::= { inUtilizationEntry 1 } inUtilizationAvg OBJECT-TYPE SYNTAX CoriantTypesPercentage MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter " ::= { inUtilizationEntry 2 } inUtilizationMin OBJECT-TYPE SYNTAX CoriantTypesPercentage MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter " ::= { inUtilizationEntry 3 } inUtilizationMax OBJECT-TYPE SYNTAX CoriantTypesPercentage MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter " ::= { inUtilizationEntry 4 } outUtilization OBJECT IDENTIFIER ::= { common 4 } outUtilizationTable OBJECT-TYPE SYNTAX SEQUENCE OF OutUtilizationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for TX utilization, corresponding to pm parameter Utilization" ::= { outUtilization 1 } outUtilizationEntry OBJECT-TYPE SYNTAX OutUtilizationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of outUtilizationTable" INDEX { shelfId,slotId,subslotId,portId,subportId } ::= { outUtilizationTable 1 } OutUtilizationEntry ::= SEQUENCE { outUtilizationInstant CoriantTypesPercentage, outUtilizationAvg CoriantTypesPercentage, outUtilizationMin CoriantTypesPercentage, outUtilizationMax CoriantTypesPercentage } outUtilizationInstant OBJECT-TYPE SYNTAX CoriantTypesPercentage MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter " ::= { outUtilizationEntry 1 } outUtilizationAvg OBJECT-TYPE SYNTAX CoriantTypesPercentage MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter " ::= { outUtilizationEntry 2 } outUtilizationMin OBJECT-TYPE SYNTAX CoriantTypesPercentage MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter " ::= { outUtilizationEntry 3 } outUtilizationMax OBJECT-TYPE SYNTAX CoriantTypesPercentage MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter " ::= { outUtilizationEntry 4 } oduDelay OBJECT IDENTIFIER ::= { common 23 } oduDelayTable OBJECT-TYPE SYNTAX SEQUENCE OF OduDelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for measured odu signal delay, corresponding to pm parameter DELAY" ::= { oduDelay 1 } oduDelayEntry OBJECT-TYPE SYNTAX OduDelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of oduDelayTable" INDEX { shelfId,slotId,subslotId,portId,subportId,odutypeL1,oduidL1,odutypeL2,oduidL2,odutypeL3,oduidL3,odutypeL4,oduidL4 } ::= { oduDelayTable 1 } OduDelayEntry ::= SEQUENCE { oduDelayInstant OCTET STRING, oduDelayAvg OCTET STRING, oduDelayMin OCTET STRING, oduDelayMax OCTET STRING } oduDelayInstant OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter UNITS:microseconds " ::= { oduDelayEntry 1 } oduDelayAvg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter UNITS:microseconds " ::= { oduDelayEntry 2 } oduDelayMin OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter UNITS:microseconds " ::= { oduDelayEntry 3 } oduDelayMax OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter UNITS:microseconds " ::= { oduDelayEntry 4 } inOpticalPower OBJECT IDENTIFIER ::= { common 24 } inOpticalPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF InOpticalPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for RX optical power, corresponding to pm parameter OPT" ::= { inOpticalPower 1 } inOpticalPowerEntry OBJECT-TYPE SYNTAX InOpticalPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of inOpticalPowerTable" INDEX { shelfId,slotId,subslotId,portId,subportId,otsName,omsName,oscName,goptName,nmcName } ::= { inOpticalPowerTable 1 } InOpticalPowerEntry ::= SEQUENCE { inOpticalPowerInstant CoriantTypesOpticalPower, inOpticalPowerAvg CoriantTypesOpticalPower, inOpticalPowerMin CoriantTypesOpticalPower, inOpticalPowerMax CoriantTypesOpticalPower } inOpticalPowerInstant OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter " ::= { inOpticalPowerEntry 1 } inOpticalPowerAvg OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter " ::= { inOpticalPowerEntry 2 } inOpticalPowerMin OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter " ::= { inOpticalPowerEntry 3 } inOpticalPowerMax OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter " ::= { inOpticalPowerEntry 4 } outOpticalPower OBJECT IDENTIFIER ::= { common 25 } outOpticalPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF OutOpticalPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for TX optical power, corresponding to pm parameter OPR" ::= { outOpticalPower 1 } outOpticalPowerEntry OBJECT-TYPE SYNTAX OutOpticalPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of outOpticalPowerTable" INDEX { shelfId,slotId,subslotId,portId,subportId,otsName,omsName,oscName,goptName,nmcName } ::= { outOpticalPowerTable 1 } OutOpticalPowerEntry ::= SEQUENCE { outOpticalPowerInstant CoriantTypesOpticalPower, outOpticalPowerAvg CoriantTypesOpticalPower, outOpticalPowerMin CoriantTypesOpticalPower, outOpticalPowerMax CoriantTypesOpticalPower } outOpticalPowerInstant OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter " ::= { outOpticalPowerEntry 1 } outOpticalPowerAvg OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter " ::= { outOpticalPowerEntry 2 } outOpticalPowerMin OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter " ::= { outOpticalPowerEntry 3 } outOpticalPowerMax OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter " ::= { outOpticalPowerEntry 4 } differentialGroupDelay OBJECT IDENTIFIER ::= { common 26 } differentialGroupDelayTable OBJECT-TYPE SYNTAX SEQUENCE OF DifferentialGroupDelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for differential group delay, corresponding to pm parameter DGD" ::= { differentialGroupDelay 1 } differentialGroupDelayEntry OBJECT-TYPE SYNTAX DifferentialGroupDelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of differentialGroupDelayTable" INDEX { shelfId,slotId,subslotId,portId } ::= { differentialGroupDelayTable 1 } DifferentialGroupDelayEntry ::= SEQUENCE { differentialGroupDelayInstant Unsigned32, differentialGroupDelayAvg Unsigned32, differentialGroupDelayMin Unsigned32, differentialGroupDelayMax Unsigned32 } differentialGroupDelayInstant OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter UNITS:ps " ::= { differentialGroupDelayEntry 1 } differentialGroupDelayAvg OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter UNITS:ps " ::= { differentialGroupDelayEntry 2 } differentialGroupDelayMin OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter UNITS:ps " ::= { differentialGroupDelayEntry 3 } differentialGroupDelayMax OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter UNITS:ps " ::= { differentialGroupDelayEntry 4 } chromaticDispersion OBJECT IDENTIFIER ::= { common 27 } chromaticDispersionTable OBJECT-TYPE SYNTAX SEQUENCE OF ChromaticDispersionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for chromatic dispersion, corresponding to pm parameter CD" ::= { chromaticDispersion 1 } chromaticDispersionEntry OBJECT-TYPE SYNTAX ChromaticDispersionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of chromaticDispersionTable" INDEX { shelfId,slotId,subslotId,portId } ::= { chromaticDispersionTable 1 } ChromaticDispersionEntry ::= SEQUENCE { chromaticDispersionInstant INTEGER, chromaticDispersionAvg INTEGER, chromaticDispersionMin INTEGER, chromaticDispersionMax INTEGER } chromaticDispersionInstant OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter UNITS:ps/nm " ::= { chromaticDispersionEntry 1 } chromaticDispersionAvg OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter UNITS:ps/pm " ::= { chromaticDispersionEntry 2 } chromaticDispersionMin OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter UNITS:ps/pm " ::= { chromaticDispersionEntry 3 } chromaticDispersionMax OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter UNITS:ps/pm " ::= { chromaticDispersionEntry 4 } osnr OBJECT IDENTIFIER ::= { common 28 } osnrTable OBJECT-TYPE SYNTAX SEQUENCE OF OsnrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for osnr, corresponding to pm parameter OSNR" ::= { osnr 1 } osnrEntry OBJECT-TYPE SYNTAX OsnrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of osnrTable" INDEX { shelfId,slotId,subslotId,portId } ::= { osnrTable 1 } OsnrEntry ::= SEQUENCE { osnrInstant CoriantTypesDBPrecision1, osnrAvg CoriantTypesDBPrecision1, osnrMin CoriantTypesDBPrecision1, osnrMax CoriantTypesDBPrecision1 } osnrInstant OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter " ::= { osnrEntry 1 } osnrAvg OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter " ::= { osnrEntry 2 } osnrMin OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter " ::= { osnrEntry 3 } osnrMax OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter " ::= { osnrEntry 4 } qFactor OBJECT IDENTIFIER ::= { common 29 } qFactorTable OBJECT-TYPE SYNTAX SEQUENCE OF QFactorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for q-factor, corresponding to pm parameter Q-factor" ::= { qFactor 1 } qFactorEntry OBJECT-TYPE SYNTAX QFactorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of qFactorTable" INDEX { shelfId,slotId,subslotId,portId } ::= { qFactorTable 1 } QFactorEntry ::= SEQUENCE { qFactorInstant CoriantTypesDBPrecision1, qFactorAvg CoriantTypesDBPrecision1, qFactorMin CoriantTypesDBPrecision1, qFactorMax CoriantTypesDBPrecision1 } qFactorInstant OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter " ::= { qFactorEntry 1 } qFactorAvg OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter " ::= { qFactorEntry 2 } qFactorMin OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter " ::= { qFactorEntry 3 } qFactorMax OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter " ::= { qFactorEntry 4 } polarizationDependentLoss OBJECT IDENTIFIER ::= { common 30 } polarizationDependentLossTable OBJECT-TYPE SYNTAX SEQUENCE OF PolarizationDependentLossEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for polarization dependent loss, corresponding to pm parameter PDL" ::= { polarizationDependentLoss 1 } polarizationDependentLossEntry OBJECT-TYPE SYNTAX PolarizationDependentLossEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of polarizationDependentLossTable" INDEX { shelfId,slotId,subslotId,portId } ::= { polarizationDependentLossTable 1 } PolarizationDependentLossEntry ::= SEQUENCE { polarizationDependentLossInstant CoriantTypesDBPrecision1, polarizationDependentLossAvg CoriantTypesDBPrecision1, polarizationDependentLossMin CoriantTypesDBPrecision1, polarizationDependentLossMax CoriantTypesDBPrecision1 } polarizationDependentLossInstant OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter " ::= { polarizationDependentLossEntry 1 } polarizationDependentLossAvg OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter " ::= { polarizationDependentLossEntry 2 } polarizationDependentLossMin OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter " ::= { polarizationDependentLossEntry 3 } polarizationDependentLossMax OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter " ::= { polarizationDependentLossEntry 4 } inOpticalFrequency OBJECT IDENTIFIER ::= { common 31 } inOpticalFrequencyTable OBJECT-TYPE SYNTAX SEQUENCE OF InOpticalFrequencyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for RX optical frequency, corresponding to pm parameter OFT" ::= { inOpticalFrequency 1 } inOpticalFrequencyEntry OBJECT-TYPE SYNTAX InOpticalFrequencyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of inOpticalFrequencyTable" INDEX { shelfId,slotId,subslotId,portId } ::= { inOpticalFrequencyTable 1 } InOpticalFrequencyEntry ::= SEQUENCE { inOpticalFrequencyInstant Unsigned32, inOpticalFrequencyAvg Unsigned32, inOpticalFrequencyMin Unsigned32, inOpticalFrequencyMax Unsigned32 } inOpticalFrequencyInstant OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter UNITS:MHz " ::= { inOpticalFrequencyEntry 1 } inOpticalFrequencyAvg OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter UNITS:MHz " ::= { inOpticalFrequencyEntry 2 } inOpticalFrequencyMin OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter UNITS:MHz " ::= { inOpticalFrequencyEntry 3 } inOpticalFrequencyMax OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter UNITS:MHz " ::= { inOpticalFrequencyEntry 4 } outOpticalFrequency OBJECT IDENTIFIER ::= { common 32 } outOpticalFrequencyTable OBJECT-TYPE SYNTAX SEQUENCE OF OutOpticalFrequencyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for TX optical frequency, corresponding to pm parameter OFR" ::= { outOpticalFrequency 1 } outOpticalFrequencyEntry OBJECT-TYPE SYNTAX OutOpticalFrequencyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of outOpticalFrequencyTable" INDEX { shelfId,slotId,subslotId,portId } ::= { outOpticalFrequencyTable 1 } OutOpticalFrequencyEntry ::= SEQUENCE { outOpticalFrequencyInstant Unsigned32, outOpticalFrequencyAvg Unsigned32, outOpticalFrequencyMin Unsigned32, outOpticalFrequencyMax Unsigned32 } outOpticalFrequencyInstant OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter UNITS:MHz " ::= { outOpticalFrequencyEntry 1 } outOpticalFrequencyAvg OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter UNITS:MHz " ::= { outOpticalFrequencyEntry 2 } outOpticalFrequencyMin OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter UNITS:MHz " ::= { outOpticalFrequencyEntry 3 } outOpticalFrequencyMax OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter UNITS:MHz " ::= { outOpticalFrequencyEntry 4 } inOpticalPowerLaneHigh OBJECT IDENTIFIER ::= { common 33 } inOpticalPowerLaneHighTable OBJECT-TYPE SYNTAX SEQUENCE OF InOpticalPowerLaneHighEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for highest value of RX lane optical power, corresponding to pm parameter OPR-lane-high" ::= { inOpticalPowerLaneHigh 1 } inOpticalPowerLaneHighEntry OBJECT-TYPE SYNTAX InOpticalPowerLaneHighEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of inOpticalPowerLaneHighTable" INDEX { shelfId,slotId,subslotId,portId } ::= { inOpticalPowerLaneHighTable 1 } InOpticalPowerLaneHighEntry ::= SEQUENCE { inOpticalPowerLaneHighInstant CoriantTypesOpticalPower, inOpticalPowerLaneHighAvg CoriantTypesOpticalPower, inOpticalPowerLaneHighMin CoriantTypesOpticalPower, inOpticalPowerLaneHighMax CoriantTypesOpticalPower } inOpticalPowerLaneHighInstant OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter " ::= { inOpticalPowerLaneHighEntry 1 } inOpticalPowerLaneHighAvg OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter " ::= { inOpticalPowerLaneHighEntry 2 } inOpticalPowerLaneHighMin OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter " ::= { inOpticalPowerLaneHighEntry 3 } inOpticalPowerLaneHighMax OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter " ::= { inOpticalPowerLaneHighEntry 4 } inOpticalPowerLaneLow OBJECT IDENTIFIER ::= { common 34 } inOpticalPowerLaneLowTable OBJECT-TYPE SYNTAX SEQUENCE OF InOpticalPowerLaneLowEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for lowest value of RX lane optical power, corresponding to pm parameter OPR-lane-low" ::= { inOpticalPowerLaneLow 1 } inOpticalPowerLaneLowEntry OBJECT-TYPE SYNTAX InOpticalPowerLaneLowEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of inOpticalPowerLaneLowTable" INDEX { shelfId,slotId,subslotId,portId } ::= { inOpticalPowerLaneLowTable 1 } InOpticalPowerLaneLowEntry ::= SEQUENCE { inOpticalPowerLaneLowInstant CoriantTypesOpticalPower, inOpticalPowerLaneLowAvg CoriantTypesOpticalPower, inOpticalPowerLaneLowMin CoriantTypesOpticalPower, inOpticalPowerLaneLowMax CoriantTypesOpticalPower } inOpticalPowerLaneLowInstant OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter " ::= { inOpticalPowerLaneLowEntry 1 } inOpticalPowerLaneLowAvg OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter " ::= { inOpticalPowerLaneLowEntry 2 } inOpticalPowerLaneLowMin OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter " ::= { inOpticalPowerLaneLowEntry 3 } inOpticalPowerLaneLowMax OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter " ::= { inOpticalPowerLaneLowEntry 4 } inOpticalPowerLaneTotal OBJECT IDENTIFIER ::= { common 35 } inOpticalPowerLaneTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF InOpticalPowerLaneTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for total value of RX lane optical power, corresponding to pm parameter OPR-lane-total" ::= { inOpticalPowerLaneTotal 1 } inOpticalPowerLaneTotalEntry OBJECT-TYPE SYNTAX InOpticalPowerLaneTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of inOpticalPowerLaneTotalTable" INDEX { shelfId,slotId,subslotId,portId } ::= { inOpticalPowerLaneTotalTable 1 } InOpticalPowerLaneTotalEntry ::= SEQUENCE { inOpticalPowerLaneTotalInstant CoriantTypesOpticalPower, inOpticalPowerLaneTotalAvg CoriantTypesOpticalPower, inOpticalPowerLaneTotalMin CoriantTypesOpticalPower, inOpticalPowerLaneTotalMax CoriantTypesOpticalPower } inOpticalPowerLaneTotalInstant OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter " ::= { inOpticalPowerLaneTotalEntry 1 } inOpticalPowerLaneTotalAvg OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter " ::= { inOpticalPowerLaneTotalEntry 2 } inOpticalPowerLaneTotalMin OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter " ::= { inOpticalPowerLaneTotalEntry 3 } inOpticalPowerLaneTotalMax OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter " ::= { inOpticalPowerLaneTotalEntry 4 } outOpticalPowerLaneHigh OBJECT IDENTIFIER ::= { common 36 } outOpticalPowerLaneHighTable OBJECT-TYPE SYNTAX SEQUENCE OF OutOpticalPowerLaneHighEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for highest value of TX lane optical power, corresponding to pm parameter OPR-lane-high" ::= { outOpticalPowerLaneHigh 1 } outOpticalPowerLaneHighEntry OBJECT-TYPE SYNTAX OutOpticalPowerLaneHighEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of outOpticalPowerLaneHighTable" INDEX { shelfId,slotId,subslotId,portId } ::= { outOpticalPowerLaneHighTable 1 } OutOpticalPowerLaneHighEntry ::= SEQUENCE { outOpticalPowerLaneHighInstant CoriantTypesOpticalPower, outOpticalPowerLaneHighAvg CoriantTypesOpticalPower, outOpticalPowerLaneHighMin CoriantTypesOpticalPower, outOpticalPowerLaneHighMax CoriantTypesOpticalPower } outOpticalPowerLaneHighInstant OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter " ::= { outOpticalPowerLaneHighEntry 1 } outOpticalPowerLaneHighAvg OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter " ::= { outOpticalPowerLaneHighEntry 2 } outOpticalPowerLaneHighMin OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter " ::= { outOpticalPowerLaneHighEntry 3 } outOpticalPowerLaneHighMax OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter " ::= { outOpticalPowerLaneHighEntry 4 } outOpticalPowerLaneLow OBJECT IDENTIFIER ::= { common 37 } outOpticalPowerLaneLowTable OBJECT-TYPE SYNTAX SEQUENCE OF OutOpticalPowerLaneLowEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for lowest value of TX lane optical power, corresponding to pm parameter OPR-lane-low" ::= { outOpticalPowerLaneLow 1 } outOpticalPowerLaneLowEntry OBJECT-TYPE SYNTAX OutOpticalPowerLaneLowEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of outOpticalPowerLaneLowTable" INDEX { shelfId,slotId,subslotId,portId } ::= { outOpticalPowerLaneLowTable 1 } OutOpticalPowerLaneLowEntry ::= SEQUENCE { outOpticalPowerLaneLowInstant CoriantTypesOpticalPower, outOpticalPowerLaneLowAvg CoriantTypesOpticalPower, outOpticalPowerLaneLowMin CoriantTypesOpticalPower, outOpticalPowerLaneLowMax CoriantTypesOpticalPower } outOpticalPowerLaneLowInstant OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter " ::= { outOpticalPowerLaneLowEntry 1 } outOpticalPowerLaneLowAvg OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter " ::= { outOpticalPowerLaneLowEntry 2 } outOpticalPowerLaneLowMin OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter " ::= { outOpticalPowerLaneLowEntry 3 } outOpticalPowerLaneLowMax OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter " ::= { outOpticalPowerLaneLowEntry 4 } outOpticalPowerLaneTotal OBJECT IDENTIFIER ::= { common 38 } outOpticalPowerLaneTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF OutOpticalPowerLaneTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for total value of TX lane optical power, corresponding to pm parameter OPR-lane-total" ::= { outOpticalPowerLaneTotal 1 } outOpticalPowerLaneTotalEntry OBJECT-TYPE SYNTAX OutOpticalPowerLaneTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of outOpticalPowerLaneTotalTable" INDEX { shelfId,slotId,subslotId,portId } ::= { outOpticalPowerLaneTotalTable 1 } OutOpticalPowerLaneTotalEntry ::= SEQUENCE { outOpticalPowerLaneTotalInstant CoriantTypesOpticalPower, outOpticalPowerLaneTotalAvg CoriantTypesOpticalPower, outOpticalPowerLaneTotalMin CoriantTypesOpticalPower, outOpticalPowerLaneTotalMax CoriantTypesOpticalPower } outOpticalPowerLaneTotalInstant OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter " ::= { outOpticalPowerLaneTotalEntry 1 } outOpticalPowerLaneTotalAvg OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter " ::= { outOpticalPowerLaneTotalEntry 2 } outOpticalPowerLaneTotalMin OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter " ::= { outOpticalPowerLaneTotalEntry 3 } outOpticalPowerLaneTotalMax OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter " ::= { outOpticalPowerLaneTotalEntry 4 } moduleTemperature OBJECT IDENTIFIER ::= { common 39 } moduleTemperatureTable OBJECT-TYPE SYNTAX SEQUENCE OF ModuleTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for module temperature, corresponding to pm parameter T-module" ::= { moduleTemperature 1 } moduleTemperatureEntry OBJECT-TYPE SYNTAX ModuleTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of moduleTemperatureTable" INDEX { shelfId,slotId,subslotId } ::= { moduleTemperatureTable 1 } ModuleTemperatureEntry ::= SEQUENCE { moduleTemperatureInstant CoriantTypesTemperaturePrecision3, moduleTemperatureAvg CoriantTypesTemperaturePrecision3, moduleTemperatureMin CoriantTypesTemperaturePrecision3, moduleTemperatureMax CoriantTypesTemperaturePrecision3 } moduleTemperatureInstant OBJECT-TYPE SYNTAX CoriantTypesTemperaturePrecision3 MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter " ::= { moduleTemperatureEntry 1 } moduleTemperatureAvg OBJECT-TYPE SYNTAX CoriantTypesTemperaturePrecision3 MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter " ::= { moduleTemperatureEntry 2 } moduleTemperatureMin OBJECT-TYPE SYNTAX CoriantTypesTemperaturePrecision3 MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter " ::= { moduleTemperatureEntry 3 } moduleTemperatureMax OBJECT-TYPE SYNTAX CoriantTypesTemperaturePrecision3 MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter " ::= { moduleTemperatureEntry 4 } inletTemperature OBJECT IDENTIFIER ::= { common 40 } inletTemperatureTable OBJECT-TYPE SYNTAX SEQUENCE OF InletTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for inlet temperature, corresponding to pm parameter T-inlet" ::= { inletTemperature 1 } inletTemperatureEntry OBJECT-TYPE SYNTAX InletTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of inletTemperatureTable" INDEX { shelfId } ::= { inletTemperatureTable 1 } InletTemperatureEntry ::= SEQUENCE { inletTemperatureInstant CoriantTypesTemperaturePrecision3, inletTemperatureAvg CoriantTypesTemperaturePrecision3, inletTemperatureMin CoriantTypesTemperaturePrecision3, inletTemperatureMax CoriantTypesTemperaturePrecision3 } inletTemperatureInstant OBJECT-TYPE SYNTAX CoriantTypesTemperaturePrecision3 MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter " ::= { inletTemperatureEntry 1 } inletTemperatureAvg OBJECT-TYPE SYNTAX CoriantTypesTemperaturePrecision3 MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter " ::= { inletTemperatureEntry 2 } inletTemperatureMin OBJECT-TYPE SYNTAX CoriantTypesTemperaturePrecision3 MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter " ::= { inletTemperatureEntry 3 } inletTemperatureMax OBJECT-TYPE SYNTAX CoriantTypesTemperaturePrecision3 MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter " ::= { inletTemperatureEntry 4 } outletTemperature OBJECT IDENTIFIER ::= { common 41 } outletTemperatureTable OBJECT-TYPE SYNTAX SEQUENCE OF OutletTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for outlet temperature, corresponding to pm parameter T-outlet" ::= { outletTemperature 1 } outletTemperatureEntry OBJECT-TYPE SYNTAX OutletTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of outletTemperatureTable" INDEX { shelfId } ::= { outletTemperatureTable 1 } OutletTemperatureEntry ::= SEQUENCE { outletTemperatureInstant CoriantTypesTemperaturePrecision3, outletTemperatureAvg CoriantTypesTemperaturePrecision3, outletTemperatureMin CoriantTypesTemperaturePrecision3, outletTemperatureMax CoriantTypesTemperaturePrecision3 } outletTemperatureInstant OBJECT-TYPE SYNTAX CoriantTypesTemperaturePrecision3 MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter " ::= { outletTemperatureEntry 1 } outletTemperatureAvg OBJECT-TYPE SYNTAX CoriantTypesTemperaturePrecision3 MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter " ::= { outletTemperatureEntry 2 } outletTemperatureMin OBJECT-TYPE SYNTAX CoriantTypesTemperaturePrecision3 MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter " ::= { outletTemperatureEntry 3 } outletTemperatureMax OBJECT-TYPE SYNTAX CoriantTypesTemperaturePrecision3 MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter " ::= { outletTemperatureEntry 4 } opticalReturnLoss OBJECT IDENTIFIER ::= { common 42 } opticalReturnLossTable OBJECT-TYPE SYNTAX SEQUENCE OF OpticalReturnLossEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for return loss, corresponding to pm parameter ORL" ::= { opticalReturnLoss 1 } opticalReturnLossEntry OBJECT-TYPE SYNTAX OpticalReturnLossEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of opticalReturnLossTable" INDEX { omsName } ::= { opticalReturnLossTable 1 } OpticalReturnLossEntry ::= SEQUENCE { opticalReturnLossInstant CoriantTypesDBPrecision1, opticalReturnLossAvg CoriantTypesDBPrecision1, opticalReturnLossMin CoriantTypesDBPrecision1, opticalReturnLossMax CoriantTypesDBPrecision1 } opticalReturnLossInstant OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter " ::= { opticalReturnLossEntry 1 } opticalReturnLossAvg OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter " ::= { opticalReturnLossEntry 2 } opticalReturnLossMin OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter " ::= { opticalReturnLossEntry 3 } opticalReturnLossMax OBJECT-TYPE SYNTAX CoriantTypesDBPrecision1 MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter " ::= { opticalReturnLossEntry 4 } sopChangeRate OBJECT IDENTIFIER ::= { common 43 } sopChangeRateTable OBJECT-TYPE SYNTAX SEQUENCE OF SopChangeRateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "statistics value: average, minimum, maximum and instant value for SOP change rate, corresponding to pm parameter SOP" ::= { sopChangeRate 1 } sopChangeRateEntry OBJECT-TYPE SYNTAX SopChangeRateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of sopChangeRateTable" INDEX { shelfId,slotId,subslotId,portId } ::= { sopChangeRateTable 1 } SopChangeRateEntry ::= SEQUENCE { sopChangeRateInstant Unsigned32, sopChangeRateAvg Unsigned32, sopChangeRateMin Unsigned32, sopChangeRateMax Unsigned32 } sopChangeRateInstant OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "the instant value of statistics counter UNITS:rads/s " ::= { sopChangeRateEntry 1 } sopChangeRateAvg OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "the average value of statistics counter UNITS:rads/s " ::= { sopChangeRateEntry 2 } sopChangeRateMin OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "the minimum value of statistics counter UNITS:rads/s " ::= { sopChangeRateEntry 3 } sopChangeRateMax OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "the maximum value of statistics counter UNITS:rads/s " ::= { sopChangeRateEntry 4 } hmoOcmPort OBJECT IDENTIFIER ::= { groove 15 } rawData OBJECT IDENTIFIER ::= { hmoOcmPort 1 } rawDataTable OBJECT-TYPE SYNTAX SEQUENCE OF RawDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Contains ocm raw measure data." ::= { rawData 1 } rawDataEntry OBJECT-TYPE SYNTAX RawDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of rawDataTable" INDEX { shelfId,slotId,subslotId,portId } ::= { rawDataTable 1 } RawDataEntry ::= SEQUENCE { rawDataRefreshCounter Unsigned32, rawDataValidNum Unsigned32 } rawDataRefreshCounter OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "count the ocm-raw-data refreshed times. default value :0" ::= { rawDataEntry 1 } rawDataValidNum OBJECT-TYPE SYNTAX Unsigned32 (0..136) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of valid ocm-raw-data list. Example, if this values is 10, means only the key index-id 0..9 is valid. default value :0" ::= { rawDataEntry 2 } rawDataList OBJECT IDENTIFIER ::= { hmoOcmPort 2 } rawDataListTable OBJECT-TYPE SYNTAX SEQUENCE OF RawDataListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Kinds of raw measure data reported from ocm." ::= { rawDataList 1 } rawDataListEntry OBJECT-TYPE SYNTAX RawDataListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of rawDataListTable" INDEX { shelfId,slotId,subslotId,portId,rawDataListIndexId } ::= { rawDataListTable 1 } RawDataListEntry ::= SEQUENCE { rawDataListIndexId Unsigned32, rawDataListOchId Unsigned32, rawDataListNmcId Unsigned32, rawDataListActualOpticalPower CoriantTypesOpticalPower, rawDataListChannelFrequency Unsigned32, rawDataListActualChannelFrequency Unsigned32, rawDataListActualChannelWidth Unsigned32, rawDataListActualChannelRange Unsigned32, rawDataListActualChannelOsnr CoriantTypesOpticalDB, rawDataListHighPowerAttenuation CoriantTypesDecimalFract2, rawDataListHighPowerStatus INTEGER } rawDataListIndexId OBJECT-TYPE SYNTAX Unsigned32 (0..135) MAX-ACCESS read-only STATUS current DESCRIPTION "Integer ID of the ocm-raw-data. " ::= { rawDataListEntry 1 } rawDataListOchId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Use target frequency as och id, the id is defined to uniquely identify the och optical interface. " ::= { rawDataListEntry 2 } rawDataListNmcId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The id is defined to uniquely identify the nmc optical interface. " ::= { rawDataListEntry 3 } rawDataListActualOpticalPower OBJECT-TYPE SYNTAX CoriantTypesOpticalPower MAX-ACCESS read-only STATUS current DESCRIPTION "Actual optical power. " ::= { rawDataListEntry 4 } rawDataListChannelFrequency OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "channel center frequency. UNITS:MHz " ::= { rawDataListEntry 5 } rawDataListActualChannelFrequency OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual channel center frequency. UNITS:MHz " ::= { rawDataListEntry 6 } rawDataListActualChannelWidth OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual channel width with unit MHz. UNITS:MHz " ::= { rawDataListEntry 7 } rawDataListActualChannelRange OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual channel range. " ::= { rawDataListEntry 8 } rawDataListActualChannelOsnr OBJECT-TYPE SYNTAX CoriantTypesOpticalDB MAX-ACCESS read-only STATUS current DESCRIPTION "Actual channel Optical Signal Noise Ratio. " ::= { rawDataListEntry 9 } rawDataListHighPowerAttenuation OBJECT-TYPE SYNTAX CoriantTypesDecimalFract2 MAX-ACCESS read-only STATUS current DESCRIPTION "the attenuation value for nmc high power UNITS:dB default value :99" ::= { rawDataListEntry 10 } rawDataListHighPowerStatus OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "nmc high power state default value :99" ::= { rawDataListEntry 11 } hmo OBJECT IDENTIFIER ::= { groove 16 } wssActualVoa OBJECT IDENTIFIER ::= { hmo 2 } wssActualVoaTable OBJECT-TYPE SYNTAX SEQUENCE OF WssActualVoaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { wssActualVoa 1 } wssActualVoaEntry OBJECT-TYPE SYNTAX WssActualVoaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of wssActualVoaTable" INDEX { shelfId,slotId,subslotId } ::= { wssActualVoaTable 1 } WssActualVoaEntry ::= SEQUENCE { wssActualVoaTriggerCounter Unsigned32, wssActualVoaNmcTotalNumber Unsigned32, wssActualVoaDirectionType INTEGER } wssActualVoaTriggerCounter OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "used to trigger callback default value :0" ::= { wssActualVoaEntry 1 } wssActualVoaNmcTotalNumber OBJECT-TYPE SYNTAX Unsigned32 (0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "used to record the total number of nmcs whose voa change default value :0" ::= { wssActualVoaEntry 2 } wssActualVoaDirectionType OBJECT-TYPE SYNTAX INTEGER { notAvailable (0), input (1), output (2), bidirection (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "the direction of voa configure for nmc default value :not-available" ::= { wssActualVoaEntry 3 } nmcActualVoa OBJECT IDENTIFIER ::= { hmo 3 } nmcActualVoaTable OBJECT-TYPE SYNTAX SEQUENCE OF NmcActualVoaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Kinds of nmc voa reported from wss." ::= { nmcActualVoa 1 } nmcActualVoaEntry OBJECT-TYPE SYNTAX NmcActualVoaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of nmcActualVoaTable" INDEX { shelfId,slotId,subslotId,nmcTargetVoaNmcTmpId } ::= { nmcActualVoaTable 1 } NmcActualVoaEntry ::= SEQUENCE { nmcActualVoaNmcTmpId Unsigned32, nmcActualVoaNmcId Unsigned32, nmcActualVoaInputAttenuation CoriantTypesDecimalFract2, nmcActualVoaOutputAttenuation CoriantTypesDecimalFract2 } nmcActualVoaNmcTmpId OBJECT-TYPE SYNTAX Unsigned32 (1..128) MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { nmcActualVoaEntry 1 } nmcActualVoaNmcId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "0 " ::= { nmcActualVoaEntry 2 } nmcActualVoaInputAttenuation OBJECT-TYPE SYNTAX CoriantTypesDecimalFract2 MAX-ACCESS read-only STATUS current DESCRIPTION "the voa value for nmc input direction UNITS:dB default value :0.0" ::= { nmcActualVoaEntry 3 } nmcActualVoaOutputAttenuation OBJECT-TYPE SYNTAX CoriantTypesDecimalFract2 MAX-ACCESS read-only STATUS current DESCRIPTION "the voa value for nmc output direction UNITS:dB default value :0.0" ::= { nmcActualVoaEntry 4 } wssTargetVoa OBJECT IDENTIFIER ::= { hmo 4 } wssTargetVoaTable OBJECT-TYPE SYNTAX SEQUENCE OF WssTargetVoaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { wssTargetVoa 1 } wssTargetVoaEntry OBJECT-TYPE SYNTAX WssTargetVoaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of wssTargetVoaTable" INDEX { shelfId,slotId,subslotId } ::= { wssTargetVoaTable 1 } WssTargetVoaEntry ::= SEQUENCE { wssTargetVoaTriggerCounter Unsigned32, wssTargetVoaNmcTotalNumber Unsigned32, wssTargetVoaDirectionType INTEGER } wssTargetVoaTriggerCounter OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "used to trigger callback default value :0" ::= { wssTargetVoaEntry 1 } wssTargetVoaNmcTotalNumber OBJECT-TYPE SYNTAX Unsigned32 (0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "used to record the total number of nmcs whose voa change default value :0" ::= { wssTargetVoaEntry 2 } wssTargetVoaDirectionType OBJECT-TYPE SYNTAX INTEGER { notAvailable (0), input (1), output (2), bidirection (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "the direction of voa configure for nmc default value :not-available" ::= { wssTargetVoaEntry 3 } nmcTargetVoa OBJECT IDENTIFIER ::= { hmo 5 } nmcTargetVoaTable OBJECT-TYPE SYNTAX SEQUENCE OF NmcTargetVoaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Kinds of nmc voa reported from wss." ::= { nmcTargetVoa 1 } nmcTargetVoaEntry OBJECT-TYPE SYNTAX NmcTargetVoaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of nmcTargetVoaTable" INDEX { shelfId,slotId,subslotId,nmcTargetVoaNmcTmpId } ::= { nmcTargetVoaTable 1 } NmcTargetVoaEntry ::= SEQUENCE { nmcTargetVoaNmcTmpId Unsigned32, nmcTargetVoaNmcId Unsigned32, nmcTargetVoaInputAttenuation CoriantTypesDecimalFract2, nmcTargetVoaOutputAttenuation CoriantTypesDecimalFract2 } nmcTargetVoaNmcTmpId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { nmcTargetVoaEntry 1 } nmcTargetVoaNmcId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "0 " ::= { nmcTargetVoaEntry 2 } nmcTargetVoaInputAttenuation OBJECT-TYPE SYNTAX CoriantTypesDecimalFract2 MAX-ACCESS read-only STATUS current DESCRIPTION "the voa value for nmc input direction UNITS:dB default value :0.0" ::= { nmcTargetVoaEntry 3 } nmcTargetVoaOutputAttenuation OBJECT-TYPE SYNTAX CoriantTypesDecimalFract2 MAX-ACCESS read-only STATUS current DESCRIPTION "the voa value for nmc output direction UNITS:dB default value :0.0" ::= { nmcTargetVoaEntry 4 } nmcReference OBJECT IDENTIFIER ::= { hmo 6 } nmcReferenceTable OBJECT-TYPE SYNTAX SEQUENCE OF NmcReferenceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the Network Media Channel (NMC) MO" ::= { nmcReference 1 } nmcReferenceEntry OBJECT-TYPE SYNTAX NmcReferenceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of nmcReferenceTable" INDEX { nmcReferenceId } ::= { nmcReferenceTable 1 } NmcReferenceEntry ::= SEQUENCE { nmcReferenceId Unsigned32, nmcReferenceOcmNmcSourceRefId Unsigned32 } nmcReferenceId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "NULL " ::= { nmcReferenceEntry 1 } nmcReferenceOcmNmcSourceRefId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Record the nbi nmc ref id in the ocm nmc which used to mapping to NBI NMC. " ::= { nmcReferenceEntry 2 } ochReference OBJECT IDENTIFIER ::= { hmo 7 } ochReferenceTable OBJECT-TYPE SYNTAX SEQUENCE OF OchReferenceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents the Optical Channel (OCH) MO" ::= { ochReference 1 } ochReferenceEntry OBJECT-TYPE SYNTAX OchReferenceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of ochReferenceTable" INDEX { ochReferenceOchName } ::= { ochReferenceTable 1 } OchReferenceEntry ::= SEQUENCE { ochReferenceOchName CoriantTypesNameIdentifier, ochReferenceOchFrequency Unsigned32, ochReferenceOchWidth OCTET STRING, ochReferenceMaxAttenuation CoriantTypesDecimalFract2, ochReferenceTargetAttenuation CoriantTypesDecimalFract2, ochReferenceActualAttenuation CoriantTypesDecimalFract2 } ochReferenceOchName OBJECT-TYPE SYNTAX CoriantTypesNameIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "The name is defined to uniquely identify the och optical interface. " ::= { ochReferenceEntry 1 } ochReferenceOchFrequency OBJECT-TYPE SYNTAX Unsigned32 (0|191300000..196125000) MAX-ACCESS read-only STATUS current DESCRIPTION "Frequency of the channel with unit MHz. UNITS:MHz " ::= { ochReferenceEntry 2 } ochReferenceOchWidth OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Wavelength of the channel with unit nm. UNITS:nm " ::= { ochReferenceEntry 3 } ochReferenceMaxAttenuation OBJECT-TYPE SYNTAX CoriantTypesDecimalFract2 MAX-ACCESS read-only STATUS current DESCRIPTION "the voa value for nmc input direction UNITS:dB default value :0.0" ::= { ochReferenceEntry 4 } ochReferenceTargetAttenuation OBJECT-TYPE SYNTAX CoriantTypesDecimalFract2 MAX-ACCESS read-only STATUS current DESCRIPTION "the voa value for nmc input direction UNITS:dB default value :0.0" ::= { ochReferenceEntry 5 } ochReferenceActualAttenuation OBJECT-TYPE SYNTAX CoriantTypesDecimalFract2 MAX-ACCESS read-only STATUS current DESCRIPTION "the voa value for nmc input direction UNITS:dB default value :0.0" ::= { ochReferenceEntry 6 } telemetry OBJECT IDENTIFIER ::= { groove 19 } sensorGroup OBJECT IDENTIFIER ::= { telemetry 3 } sensorGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of telemetry sensory groups on the local system, where a sensor grouping represents a resuable grouping of multiple paths and exclude filters." ::= { sensorGroup 1 } sensorGroupEntry OBJECT-TYPE SYNTAX SensorGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of sensorGroupTable" INDEX { sensorGroupId } ::= { sensorGroupTable 1 } SensorGroupEntry ::= SEQUENCE { sensorGroupId OCTET STRING } sensorGroupId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name or identifier for the sensor group itself. Will be referenced by other configuration specifying a sensor group " ::= { sensorGroupEntry 1 } sensorPath OBJECT IDENTIFIER ::= { telemetry 5 } sensorPathTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorPathEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of paths in the model which together comprise a sensor grouping. Filters for each path to exclude items are also provided." ::= { sensorPath 1 } sensorPathEntry OBJECT-TYPE SYNTAX SensorPathEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of sensorPathTable" INDEX { sensorGroupId,sensorPathIndex } ::= { sensorPathTable 1 } SensorPathEntry ::= SEQUENCE { sensorPathIndex OCTET STRING, sensorPathModelPath OCTET STRING, sensorPathExcludeFilter OCTET STRING } sensorPathIndex OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..320)) MAX-ACCESS read-only STATUS current DESCRIPTION "index for sensor-path " ::= { sensorPathEntry 1 } sensorPathModelPath OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Path to a section of operational state of interest (the sensor). " ::= { sensorPathEntry 2 } sensorPathExcludeFilter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Filter to exclude certain values out of the state values " ::= { sensorPathEntry 3 } destinationGroup OBJECT IDENTIFIER ::= { telemetry 7 } destinationGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF DestinationGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of destination-groups. Destination groups allow the reuse of common telemetry destinations across the telemetry configuration. An operator references a set of destinations via the configurable destination-group-identifier. A destination group may contain one or more telemetry destinations" ::= { destinationGroup 1 } destinationGroupEntry OBJECT-TYPE SYNTAX DestinationGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of destinationGroupTable" INDEX { destinationGroupGroupId } ::= { destinationGroupTable 1 } DestinationGroupEntry ::= SEQUENCE { destinationGroupGroupId OCTET STRING } destinationGroupGroupId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique identifier for the destination group " ::= { destinationGroupEntry 1 } destination OBJECT IDENTIFIER ::= { telemetry 9 } destinationTable OBJECT-TYPE SYNTAX SEQUENCE OF DestinationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of telemetry stream destinations" ::= { destination 1 } destinationEntry OBJECT-TYPE SYNTAX DestinationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of destinationTable" INDEX { destinationGroupGroupId,destinationAddress,destinationPort } ::= { destinationTable 1 } DestinationEntry ::= SEQUENCE { destinationAddress IetfInetTypesIpAddress, destinationPort IetfInetTypesPortNumber } destinationAddress OBJECT-TYPE SYNTAX IetfInetTypesIpAddress (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "IP address of the telemetry stream destination " ::= { destinationEntry 1 } destinationPort OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Protocol (udp or tcp) port number for the telemetry stream destination " ::= { destinationEntry 2 } dialOutSubscription OBJECT IDENTIFIER ::= { telemetry 12 } dialOutSubscriptionTable OBJECT-TYPE SYNTAX SEQUENCE OF DialOutSubscriptionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of telemetry subscriptions. A telemetry subscription consists of a set of collection destinations, stream attributes, and associated paths to state information in the model (sensor data)" ::= { dialOutSubscription 1 } dialOutSubscriptionEntry OBJECT-TYPE SYNTAX DialOutSubscriptionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of dialOutSubscriptionTable" INDEX { dialOutSubscriptionSubscriptionName } ::= { dialOutSubscriptionTable 1 } DialOutSubscriptionEntry ::= SEQUENCE { dialOutSubscriptionStartStreamingTime IetfYangTypesDateAndTime, dialOutSubscriptionStreamingDataModel INTEGER, dialOutSubscriptionSubscriptionName OCTET STRING, dialOutSubscriptionSubscriptionId OCTET STRING, dialOutSubscriptionLocalSourceAddress OCTET STRING, dialOutSubscriptionOriginatedQosMarking IetfInetTypesDscp, dialOutSubscriptionProtocol INTEGER, dialOutSubscriptionEncoding INTEGER } dialOutSubscriptionStartStreamingTime OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The time of the subscription first streaming data packet send out. If the time is default value the packet will send immediately after subscription setting completed. If the time is passed the packet will send out at the next integral multiple of sample interval since the start-streaming-time. If the time is not yet the first packet will be sent out at the start-streaming-time default value :0000-01-01T00:00:00.000Z" ::= { dialOutSubscriptionEntry 1 } dialOutSubscriptionStreamingDataModel OBJECT-TYPE SYNTAX INTEGER { auto (1), deviceModel (2), openconfig (3), openroadm (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The stream out data based on selected model default value :Device-model" ::= { dialOutSubscriptionEntry 2 } dialOutSubscriptionSubscriptionName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "User configured identifier of the telemetry subscription. This value is used primarily for subscriptions configured locally on the network element. " ::= { dialOutSubscriptionEntry 3 } dialOutSubscriptionSubscriptionId OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "System generated identifer of the telemetry subscription. " ::= { dialOutSubscriptionEntry 4 } dialOutSubscriptionLocalSourceAddress OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address which will be the source of packets from the device to a telemetry collector destination. default value :auto" ::= { dialOutSubscriptionEntry 5 } dialOutSubscriptionOriginatedQosMarking OBJECT-TYPE SYNTAX IetfInetTypesDscp MAX-ACCESS read-only STATUS current DESCRIPTION "DSCP marking of packets generated by the telemetry subsystem on the network device. default value :0" ::= { dialOutSubscriptionEntry 6 } dialOutSubscriptionProtocol OBJECT-TYPE SYNTAX INTEGER { ssh (1), grpc (2), jsonRpc (3), websocketRpc (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Selection of the transport protocol for the telemetry stream. default value :GRPC" ::= { dialOutSubscriptionEntry 7 } dialOutSubscriptionEncoding OBJECT-TYPE SYNTAX INTEGER { xml (1), jsonIetf (2), proto3 (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Selection of the specific encoding or RPC framework for telemetry messages to and from the network element. default value :JSON_IETF" ::= { dialOutSubscriptionEntry 8 } sensorProfile OBJECT IDENTIFIER ::= { telemetry 14 } sensorProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of telemetry sensor groups used in the subscription" ::= { sensorProfile 1 } sensorProfileEntry OBJECT-TYPE SYNTAX SensorProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of sensorProfileTable" INDEX { dialOutSubscriptionSubscriptionName } ::= { sensorProfileTable 1 } SensorProfileEntry ::= SEQUENCE { sensorProfileSensorGroup RowPointer, sensorProfileSampleInterval OCTET STRING, sensorProfileHeartbeatInterval OCTET STRING, sensorProfileSuppressRedundant TruthValue } sensorProfileSensorGroup OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Reference to the sensor group which is used in the profile " ::= { sensorProfileEntry 1 } sensorProfileSampleInterval OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Time in milliseconds between the device's sample of a telemetry data source. For example, setting this to 2000 would require the local device to collect the telemetry data every 2000 milliseconds. There can be latency or jitter in transmitting the data, but the sample must occur at the specified interval. The timestamp must reflect the actual time when the data was sampled, not simply the previous sample timestamp + sample-interval. If sample-interval is set to 0, the telemetry sensor becomes event based. The sensor must then emit data upon every change of the underlying data source. UNITS:millisecond default value :10000" ::= { sensorProfileEntry 2 } sensorProfileHeartbeatInterval OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum time interval in milliseconds that may pass between updates from a device to a telemetry collector. If this interval expires, but there is no updated data to send (such as if suppress_updates has been configured), the device must send a telemetry message to the collector. UNITS:millisecond default value :20000" ::= { sensorProfileEntry 3 } sensorProfileSuppressRedundant OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Boolean flag to control suppression of redundant telemetry updates to the collector platform. If this flag is set to TRUE, then the collector will only send an update at the configured interval if a subscribed data value has changed. Otherwise, the device will not send an update to the collector until expiration of the heartbeat interval. default value :true" ::= { sensorProfileEntry 4 } destinationProfile OBJECT IDENTIFIER ::= { telemetry 16 } destinationProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF DestinationProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Identifier of the previously defined destination group" ::= { destinationProfile 1 } destinationProfileEntry OBJECT-TYPE SYNTAX DestinationProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of destinationProfileTable" INDEX { dialOutSubscriptionSubscriptionName,destinationProfileGroupId } ::= { destinationProfileTable 1 } DestinationProfileEntry ::= SEQUENCE { destinationProfileGroupId RowPointer } destinationProfileGroupId OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "The destination group id references a reusable group of destination addresses and ports for the telemetry stream. " ::= { destinationProfileEntry 1 } dialInSubscription OBJECT IDENTIFIER ::= { telemetry 18 } dialInSubscriptionTable OBJECT-TYPE SYNTAX SEQUENCE OF DialInSubscriptionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List representation of telemetry subscriptions that are configured via an inline RPC, otherwise known as dynamic telemetry subscriptions." ::= { dialInSubscription 1 } dialInSubscriptionEntry OBJECT-TYPE SYNTAX DialInSubscriptionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of dialInSubscriptionTable" INDEX { dialInSubscriptionSubscriptionId } ::= { dialInSubscriptionTable 1 } DialInSubscriptionEntry ::= SEQUENCE { dialInSubscriptionSubscriptionId OCTET STRING } dialInSubscriptionSubscriptionId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Reference to the identifier of the subscription itself. The id will be the handle to refer to the subscription once created " ::= { dialInSubscriptionEntry 1 } stateDialInSubscription OBJECT IDENTIFIER ::= { telemetry 19 } stateDialInSubscriptionTable OBJECT-TYPE SYNTAX SEQUENCE OF StateDialInSubscriptionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "State information relating to dynamic telemetry subscriptions." ::= { stateDialInSubscription 1 } stateDialInSubscriptionEntry OBJECT-TYPE SYNTAX StateDialInSubscriptionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of stateDialInSubscriptionTable" INDEX { dialInSubscriptionSubscriptionId } ::= { stateDialInSubscriptionTable 1 } StateDialInSubscriptionEntry ::= SEQUENCE { stateDialInSubscriptionSubscriptionId OCTET STRING, stateDialInSubscriptionDestinationAddress IetfInetTypesIpAddress, stateDialInSubscriptionDestinationPort IetfInetTypesPortNumber, stateDialInSubscriptionSampleInterval OCTET STRING, stateDialInSubscriptionHeartbeatInterval OCTET STRING, stateDialInSubscriptionSuppressRedundant TruthValue, stateDialInSubscriptionProtocol INTEGER, stateDialInSubscriptionEncoding INTEGER } stateDialInSubscriptionSubscriptionId OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "System generated identifer of the telemetry subscription. " ::= { stateDialInSubscriptionEntry 1 } stateDialInSubscriptionDestinationAddress OBJECT-TYPE SYNTAX IetfInetTypesIpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address of the telemetry stream destination " ::= { stateDialInSubscriptionEntry 2 } stateDialInSubscriptionDestinationPort OBJECT-TYPE SYNTAX IetfInetTypesPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Protocol (udp or tcp) port number for the telemetry stream destination " ::= { stateDialInSubscriptionEntry 3 } stateDialInSubscriptionSampleInterval OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Time in milliseconds between the device's sample of a telemetry data source. For example, setting this to 2000 would require the local device to collect the telemetry data every 2000 milliseconds. There can be latency or jitter in transmitting the data, but the sample must occur at the specified interval. The timestamp must reflect the actual time when the data was sampled, not simply the previous sample timestamp + sample-interval. If sample-interval is set to 0, the telemetry sensor becomes event based. The sensor must then emit data upon every change of the underlying data source. UNITS:millisecond default value :10000" ::= { stateDialInSubscriptionEntry 4 } stateDialInSubscriptionHeartbeatInterval OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum time interval in milliseconds that may pass between updates from a device to a telemetry collector. If this interval expires, but there is no updated data to send (such as if suppress_updates has been configured), the device must send a telemetry message to the collector. UNITS:millisecond default value :20000" ::= { stateDialInSubscriptionEntry 5 } stateDialInSubscriptionSuppressRedundant OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Boolean flag to control suppression of redundant telemetry updates to the collector platform. If this flag is set to TRUE, then the collector will only send an update at the configured interval if a subscribed data value has changed. Otherwise, the device will not send an update to the collector until expiration of the heartbeat interval. default value :true" ::= { stateDialInSubscriptionEntry 6 } stateDialInSubscriptionProtocol OBJECT-TYPE SYNTAX INTEGER { ssh (1), grpc (2), jsonRpc (3), websocketRpc (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Selection of the transport protocol for the telemetry stream. default value :GRPC" ::= { stateDialInSubscriptionEntry 7 } stateDialInSubscriptionEncoding OBJECT-TYPE SYNTAX INTEGER { xml (1), jsonIetf (2), proto3 (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Selection of the specific encoding or RPC framework for telemetry messages to and from the network element. default value :JSON_IETF" ::= { stateDialInSubscriptionEntry 8 } dialInSensorPath OBJECT IDENTIFIER ::= { telemetry 21 } dialInSensorPathTable OBJECT-TYPE SYNTAX SEQUENCE OF DialInSensorPathEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of paths in the model which together comprise a sensor grouping. Filters for each path to exclude items are also provided." ::= { dialInSensorPath 1 } dialInSensorPathEntry OBJECT-TYPE SYNTAX DialInSensorPathEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of dialInSensorPathTable" INDEX { dialInSubscriptionSubscriptionId,dialInSensorPathPath } ::= { dialInSensorPathTable 1 } DialInSensorPathEntry ::= SEQUENCE { dialInSensorPathPath OCTET STRING } dialInSensorPathPath OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..320)) MAX-ACCESS read-only STATUS current DESCRIPTION "Reference to the path of interest " ::= { dialInSensorPathEntry 1 } pathState OBJECT IDENTIFIER ::= { telemetry 22 } pathStateTable OBJECT-TYPE SYNTAX SEQUENCE OF PathStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "State information for a dynamic subscription paths of interest" ::= { pathState 1 } pathStateEntry OBJECT-TYPE SYNTAX PathStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of pathStateTable" INDEX { dialInSubscriptionSubscriptionId,dialInSensorPathPath } ::= { pathStateTable 1 } PathStateEntry ::= SEQUENCE { pathStateModelPath OCTET STRING, pathStateExcludeFilter OCTET STRING } pathStateModelPath OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Path to a section of operational state of interest (the sensor). " ::= { pathStateEntry 1 } pathStateExcludeFilter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Filter to exclude certain values out of the state values " ::= { pathStateEntry 2 } service OBJECT IDENTIFIER ::= { groove 20 } rstpBridgeInstance OBJECT IDENTIFIER ::= { service 2 } rstpBridgeInstanceTable OBJECT-TYPE SYNTAX SEQUENCE OF RstpBridgeInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "rstp bridge instance, max instance = 4" ::= { rstpBridgeInstance 1 } rstpBridgeInstanceEntry OBJECT-TYPE SYNTAX RstpBridgeInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of rstpBridgeInstanceTable" INDEX { rstpBridgeInstanceBridgeName } ::= { rstpBridgeInstanceTable 1 } RstpBridgeInstanceEntry ::= SEQUENCE { rstpBridgeInstanceBridgeName OCTET STRING } rstpBridgeInstanceBridgeName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "unique name of the bridge " ::= { rstpBridgeInstanceEntry 1 } rstpConfig OBJECT IDENTIFIER ::= { service 3 } rstpConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF RstpConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Collection of rstp configuration attributes" ::= { rstpConfig 1 } rstpConfigEntry OBJECT-TYPE SYNTAX RstpConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of rstpConfigTable" INDEX { rstpBridgeInstanceBridgeName } ::= { rstpConfigTable 1 } RstpConfigEntry ::= SEQUENCE { rstpConfigBridgePriority Unsigned32, rstpConfigShutdown TruthValue, rstpConfigHoldTime Unsigned32, rstpConfigHelloTime Unsigned32, rstpConfigMaxAge Unsigned32, rstpConfigForwardDelay Unsigned32, rstpConfigTransmitHoldCount Unsigned32 } rstpConfigBridgePriority OBJECT-TYPE SYNTAX Unsigned32 (0..61440) MAX-ACCESS read-only STATUS current DESCRIPTION "Bridge Priority Value default value :32768" ::= { rstpConfigEntry 1 } rstpConfigShutdown OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Bridge admin state default value :false" ::= { rstpConfigEntry 2 } rstpConfigHoldTime OBJECT-TYPE SYNTAX Unsigned32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval during which no more than two BPDUs transmitted by this node in seconds - not used in rstp mode (in seconds) default value :2" ::= { rstpConfigEntry 3 } rstpConfigHelloTime OBJECT-TYPE SYNTAX Unsigned32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "The time between the transmission of BPDU's by this node on any port, when role is root (in seconds) default value :2" ::= { rstpConfigEntry 4 } rstpConfigMaxAge OBJECT-TYPE SYNTAX Unsigned32 (6..40) MAX-ACCESS read-only STATUS current DESCRIPTION "The value that all bridges use for MaxAge when this bridge is acting as the root default value :20" ::= { rstpConfigEntry 5 } rstpConfigForwardDelay OBJECT-TYPE SYNTAX Unsigned32 (4..30) MAX-ACCESS read-only STATUS current DESCRIPTION "The port on the Switch spends this time in the listening state while moving from the blocking state to the forwarding state (in seconds) default value :15" ::= { rstpConfigEntry 6 } rstpConfigTransmitHoldCount OBJECT-TYPE SYNTAX Unsigned32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum BPDU transmission rate default value :2" ::= { rstpConfigEntry 7 } rstpBridgePortTBL OBJECT IDENTIFIER ::= { service 4 } rstpBridgePortTBLTable OBJECT-TYPE SYNTAX SEQUENCE OF RstpBridgePortTBLEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table contains port-specific information for rstp config" ::= { rstpBridgePortTBL 1 } rstpBridgePortTBLEntry OBJECT-TYPE SYNTAX RstpBridgePortTBLEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of rstpBridgePortTBLTable" INDEX { rstpBridgeInstanceBridgeName,rstpBridgePortTBLIfname } ::= { rstpBridgePortTBLTable 1 } RstpBridgePortTBLEntry ::= SEQUENCE { rstpBridgePortTBLIfname RowPointer, rstpBridgePortTBLCost Unsigned32, rstpBridgePortTBLPriority Unsigned32 } rstpBridgePortTBLIfname OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Interface name of the port " ::= { rstpBridgePortTBLEntry 1 } rstpBridgePortTBLCost OBJECT-TYPE SYNTAX Unsigned32 (2000..200000) MAX-ACCESS read-only STATUS current DESCRIPTION "The contribution of this port to the path cost of paths towards the spanning tree root which include this port also default value :20000" ::= { rstpBridgePortTBLEntry 2 } rstpBridgePortTBLPriority OBJECT-TYPE SYNTAX Unsigned32 (0..240) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the priority field default value :128" ::= { rstpBridgePortTBLEntry 3 } rstpBridgeAttr OBJECT IDENTIFIER ::= { service 6 } rstpBridgeAttrTable OBJECT-TYPE SYNTAX SEQUENCE OF RstpBridgeAttrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Collection of operational rstp bridge attributes" ::= { rstpBridgeAttr 1 } rstpBridgeAttrEntry OBJECT-TYPE SYNTAX RstpBridgeAttrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of rstpBridgeAttrTable" INDEX { rstpBridgeInstanceBridgeName } ::= { rstpBridgeAttrTable 1 } RstpBridgeAttrEntry ::= SEQUENCE { rstpBridgeAttrRootBridgePort Unsigned32, rstpBridgeAttrRootPathCost Unsigned32, rstpBridgeAttrRootBridgePriority Unsigned32, rstpBridgeAttrRootBridgeId RstpBridgeIdType, rstpBridgeAttrRootHoldTime Unsigned32, rstpBridgeAttrRootHelloTime Unsigned32, rstpBridgeAttrRootMaxAge Unsigned32, rstpBridgeAttrRootForwardDelay Unsigned32, rstpBridgeAttrBridgeId RstpBridgeIdType, rstpBridgeAttrTopoChangeCount Unsigned32, rstpBridgeAttrTimeSinceTopoChange Unsigned32 } rstpBridgeAttrRootBridgePort OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Port id of the root port " ::= { rstpBridgeAttrEntry 1 } rstpBridgeAttrRootPathCost OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The cost of the path to the root as seen from this bridge " ::= { rstpBridgeAttrEntry 2 } rstpBridgeAttrRootBridgePriority OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Root Bridge Priority Value " ::= { rstpBridgeAttrEntry 3 } rstpBridgeAttrRootBridgeId OBJECT-TYPE SYNTAX RstpBridgeIdType MAX-ACCESS read-only STATUS current DESCRIPTION "Root Bridge identifier " ::= { rstpBridgeAttrEntry 4 } rstpBridgeAttrRootHoldTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval during which no more than two BPDUs transmitted by this node in seconds at root node (in seconds) UNITS:seconds " ::= { rstpBridgeAttrEntry 5 } rstpBridgeAttrRootHelloTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time between the transmission of BPDU's used at root node (in seconds) " ::= { rstpBridgeAttrEntry 6 } rstpBridgeAttrRootMaxAge OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value that all bridges use for MaxAge used at root node UNITS:seconds " ::= { rstpBridgeAttrEntry 7 } rstpBridgeAttrRootForwardDelay OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time in seconds spent on the listening state used at root node (in seconds) UNITS:seconds " ::= { rstpBridgeAttrEntry 8 } rstpBridgeAttrBridgeId OBJECT-TYPE SYNTAX RstpBridgeIdType MAX-ACCESS read-only STATUS current DESCRIPTION "Bridge identifier of the bridge " ::= { rstpBridgeAttrEntry 9 } rstpBridgeAttrTopoChangeCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of topology changes " ::= { rstpBridgeAttrEntry 10 } rstpBridgeAttrTimeSinceTopoChange OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Time since last topology changes occurred (in seconds) " ::= { rstpBridgeAttrEntry 11 } rstpBridgePortStateTBL OBJECT IDENTIFIER ::= { service 8 } rstpBridgePortStateTBLTable OBJECT-TYPE SYNTAX SEQUENCE OF RstpBridgePortStateTBLEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains port-specific information for rstp state attributes" ::= { rstpBridgePortStateTBL 1 } rstpBridgePortStateTBLEntry OBJECT-TYPE SYNTAX RstpBridgePortStateTBLEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of rstpBridgePortStateTBLTable" INDEX { rstpBridgeInstanceBridgeName,rstpBridgePortStateTBLIfname } ::= { rstpBridgePortStateTBLTable 1 } RstpBridgePortStateTBLEntry ::= SEQUENCE { rstpBridgePortStateTBLIfname RowPointer, rstpBridgePortStateTBLBridgePortState INTEGER, rstpBridgePortStateTBLBridgePortRole INTEGER, rstpBridgePortStateTBLBridgePortId Unsigned32, rstpBridgePortStateTBLOperEdgeBridgePort TruthValue, rstpBridgePortStateTBLDesignatedBridgePort Unsigned32, rstpBridgePortStateTBLDesignatedBridgeid RstpBridgeIdType } rstpBridgePortStateTBLIfname OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION "Interface name of the port " ::= { rstpBridgePortStateTBLEntry 1 } rstpBridgePortStateTBLBridgePortState OBJECT-TYPE SYNTAX INTEGER { discarding (1), blocked (2), learning (3), forwarding (4), unknown (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The port's current state default value :unknown" ::= { rstpBridgePortStateTBLEntry 2 } rstpBridgePortStateTBLBridgePortRole OBJECT-TYPE SYNTAX INTEGER { designated (1), root (2), alternate (3), disabled (4), backup (5), unknown (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The role payed by this port in the bridge default value :unknown" ::= { rstpBridgePortStateTBLEntry 3 } rstpBridgePortStateTBLBridgePortId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique port id of this port " ::= { rstpBridgePortStateTBLEntry 4 } rstpBridgePortStateTBLOperEdgeBridgePort OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The operational value of the Edge Port parameter " ::= { rstpBridgePortStateTBLEntry 5 } rstpBridgePortStateTBLDesignatedBridgePort OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Port id of the designated port " ::= { rstpBridgePortStateTBLEntry 6 } rstpBridgePortStateTBLDesignatedBridgeid OBJECT-TYPE SYNTAX RstpBridgeIdType MAX-ACCESS read-only STATUS current DESCRIPTION "The Bridge Identifier of the bridge that this port considers to be the Designated Bridge for this port's segment " ::= { rstpBridgePortStateTBLEntry 7 } hmoStatistics OBJECT IDENTIFIER ::= { groove 21 } hmoStatisticsSubcard OBJECT IDENTIFIER ::= { hmoStatistics 1 } hmoStatisticsSubcardTable OBJECT-TYPE SYNTAX SEQUENCE OF HmoStatisticsSubcardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { hmoStatisticsSubcard 1 } hmoStatisticsSubcardEntry OBJECT-TYPE SYNTAX HmoStatisticsSubcardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of hmoStatisticsSubcardTable" INDEX { shelfId,slotId,subslotId } ::= { hmoStatisticsSubcardTable 1 } HmoStatisticsSubcardEntry ::= SEQUENCE { hmoStatisticsSubcardLastClear IetfYangTypesDateAndTime } hmoStatisticsSubcardLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { hmoStatisticsSubcardEntry 1 } hmoStatisticsCard OBJECT IDENTIFIER ::= { hmoStatistics 2 } hmoStatisticsCardTable OBJECT-TYPE SYNTAX SEQUENCE OF HmoStatisticsCardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { hmoStatisticsCard 1 } hmoStatisticsCardEntry OBJECT-TYPE SYNTAX HmoStatisticsCardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of hmoStatisticsCardTable" INDEX { shelfId,slotId } ::= { hmoStatisticsCardTable 1 } HmoStatisticsCardEntry ::= SEQUENCE { hmoStatisticsCardLastClear IetfYangTypesDateAndTime } hmoStatisticsCardLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { hmoStatisticsCardEntry 1 } hmoStatisticsShelf OBJECT IDENTIFIER ::= { hmoStatistics 3 } hmoStatisticsShelfTable OBJECT-TYPE SYNTAX SEQUENCE OF HmoStatisticsShelfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { hmoStatisticsShelf 1 } hmoStatisticsShelfEntry OBJECT-TYPE SYNTAX HmoStatisticsShelfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of hmoStatisticsShelfTable" INDEX { shelfId } ::= { hmoStatisticsShelfTable 1 } HmoStatisticsShelfEntry ::= SEQUENCE { hmoStatisticsShelfLastClear IetfYangTypesDateAndTime } hmoStatisticsShelfLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { hmoStatisticsShelfEntry 1 } hmoStatisticsOts OBJECT IDENTIFIER ::= { hmoStatistics 4 } hmoStatisticsOtsTable OBJECT-TYPE SYNTAX SEQUENCE OF HmoStatisticsOtsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { hmoStatisticsOts 1 } hmoStatisticsOtsEntry OBJECT-TYPE SYNTAX HmoStatisticsOtsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of hmoStatisticsOtsTable" INDEX { otsName } ::= { hmoStatisticsOtsTable 1 } HmoStatisticsOtsEntry ::= SEQUENCE { hmoStatisticsOtsLastClear IetfYangTypesDateAndTime } hmoStatisticsOtsLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { hmoStatisticsOtsEntry 1 } hmoStatisticsOms OBJECT IDENTIFIER ::= { hmoStatistics 5 } hmoStatisticsOmsTable OBJECT-TYPE SYNTAX SEQUENCE OF HmoStatisticsOmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { hmoStatisticsOms 1 } hmoStatisticsOmsEntry OBJECT-TYPE SYNTAX HmoStatisticsOmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of hmoStatisticsOmsTable" INDEX { omsName } ::= { hmoStatisticsOmsTable 1 } HmoStatisticsOmsEntry ::= SEQUENCE { hmoStatisticsOmsLastClear IetfYangTypesDateAndTime } hmoStatisticsOmsLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { hmoStatisticsOmsEntry 1 } hmoStatisticsOsc OBJECT IDENTIFIER ::= { hmoStatistics 6 } hmoStatisticsOscTable OBJECT-TYPE SYNTAX SEQUENCE OF HmoStatisticsOscEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { hmoStatisticsOsc 1 } hmoStatisticsOscEntry OBJECT-TYPE SYNTAX HmoStatisticsOscEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of hmoStatisticsOscTable" INDEX { oscName } ::= { hmoStatisticsOscTable 1 } HmoStatisticsOscEntry ::= SEQUENCE { hmoStatisticsOscLastClear IetfYangTypesDateAndTime } hmoStatisticsOscLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { hmoStatisticsOscEntry 1 } hmoStatisticsGopt OBJECT IDENTIFIER ::= { hmoStatistics 7 } hmoStatisticsGoptTable OBJECT-TYPE SYNTAX SEQUENCE OF HmoStatisticsGoptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { hmoStatisticsGopt 1 } hmoStatisticsGoptEntry OBJECT-TYPE SYNTAX HmoStatisticsGoptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of hmoStatisticsGoptTable" INDEX { goptName } ::= { hmoStatisticsGoptTable 1 } HmoStatisticsGoptEntry ::= SEQUENCE { hmoStatisticsGoptLastClear IetfYangTypesDateAndTime, hmoStatisticsGoptProtectionSwitchDuration OCTET STRING, hmoStatisticsGoptProtectionSwitchCount OCTET STRING, hmoStatisticsGoptLossTx OCTET STRING, hmoStatisticsGoptLossRx OCTET STRING } hmoStatisticsGoptLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { hmoStatisticsGoptEntry 1 } hmoStatisticsGoptProtectionSwitchDuration OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Protection Switch Duration, corresponding to pm parameter PSD UNITS:seconds " ::= { hmoStatisticsGoptEntry 2 } hmoStatisticsGoptProtectionSwitchCount OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Protection Switch Count, corresponding to pm parameter PSC UNITS:times " ::= { hmoStatisticsGoptEntry 3 } hmoStatisticsGoptLossTx OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of Signal Seconds of Transmit side, corresponding to pm parameter LOSS-TX UNITS:seconds " ::= { hmoStatisticsGoptEntry 4 } hmoStatisticsGoptLossRx OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of Signal Seconds of Receive side, corresponding to pm parameter LOSS-RX UNITS:seconds " ::= { hmoStatisticsGoptEntry 5 } hmoStatisticsNmc OBJECT IDENTIFIER ::= { hmoStatistics 8 } hmoStatisticsNmcTable OBJECT-TYPE SYNTAX SEQUENCE OF HmoStatisticsNmcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NULL" ::= { hmoStatisticsNmc 1 } hmoStatisticsNmcEntry OBJECT-TYPE SYNTAX HmoStatisticsNmcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of hmoStatisticsNmcTable" INDEX { nmcName } ::= { hmoStatisticsNmcTable 1 } HmoStatisticsNmcEntry ::= SEQUENCE { hmoStatisticsNmcLastClear IetfYangTypesDateAndTime, hmoStatisticsNmcLossTx OCTET STRING } hmoStatisticsNmcLastClear OBJECT-TYPE SYNTAX IetfYangTypesDateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The start time of statistics monitor default value :0000-01-01T00:00:00.000Z" ::= { hmoStatisticsNmcEntry 1 } hmoStatisticsNmcLossTx OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Loss of Signal Seconds of Transmit side, corresponding to pm parameter LOSS-TX UNITS:seconds " ::= { hmoStatisticsNmcEntry 2 } END