----------------------------------------------------------------------- -- MIB table for H6520 -- -- v1.0 for firmware 9-5-0-0, 2017-04-19 ----------------------------------------------------------------------- H6520-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; DisplayString ::= OCTET STRING comet OBJECT IDENTIFIER ::= { enterprises 22626 } products OBJECT IDENTIFIER ::= { comet 1 } h6520 OBJECT IDENTIFIER ::= { products 2 } values OBJECT IDENTIFIER ::= { h6520 1 } global OBJECT IDENTIFIER ::= { h6520 2 } valuesInt OBJECT IDENTIFIER ::= { h6520 3 } settings OBJECT IDENTIFIER ::= { h6520 4 } traps OBJECT IDENTIFIER ::= { h6520 5 } tables OBJECT IDENTIFIER ::= { h6520 6 } ----------------------------------------------------------------------- -- Measured values - String ----------------------------------------------------------------------- temp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature" ::= { values 1 } hum OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Relative humidity" ::= { values 2 } compVal OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Computed value" ::= { values 3 } co2 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "CO2 level" ::= { values 4 } re1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Relay 1 state; open, closed" ::= { values 8 } re2 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Relay 2 state; open, closed" ::= { values 9 } tempAlarm1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm1 on Temperature; none, active" ::= { values 10 } humAlarm1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm1 on Relative humidity; none, active" ::= { values 11 } compValAlarm1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm1 on Computed value; none, active" ::= { values 12 } co2Alarm1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm1 on CO2 level; none, active" ::= { values 13 } tempAlarm2 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm2 on Temperature; none, active" ::= { values 14 } humAlarm2 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm2 on Relative humidity; none, active" ::= { values 15 } compValAlarm2 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm2 on Computed value; none, active" ::= { values 16 } co2Alarm2 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm2 on CO2 level; none, active" ::= { values 17 } tempUnit OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature Unit" ::= { values 21 } humUnit OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Relative humidity Unit" ::= { values 22 } compValUnit OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Computed value Unit" ::= { values 23 } co2Unit OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "CO2 level Unit" ::= { values 24 } ----------------------------------------------------------------------- -- Device informations ----------------------------------------------------------------------- sensorName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..68)) ACCESS read-only STATUS mandatory DESCRIPTION "Device name" ::= { global 1 } serialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "Serial number" ::= { global 2 } deviceType OBJECT-TYPE SYNTAX INTEGER (0..65534) ACCESS read-only STATUS mandatory DESCRIPTION "Device type" ::= { global 3 } ----------------------------------------------------------------------- -- Measured values - Integer ----------------------------------------------------------------------- tempInt OBJECT-TYPE SYNTAX INTEGER (-5000..20000) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature (value*10)" ::= { valuesInt 1 } humInt OBJECT-TYPE SYNTAX INTEGER (-5000..20000) ACCESS read-only STATUS mandatory DESCRIPTION "Relative humidity (value*10)" ::= { valuesInt 2 } compValInt OBJECT-TYPE SYNTAX INTEGER (-5000..20000) ACCESS read-only STATUS mandatory DESCRIPTION "Computed value (value*10)" ::= { valuesInt 3 } co2Int OBJECT-TYPE SYNTAX INTEGER (-5000..20000) ACCESS read-only STATUS mandatory DESCRIPTION "CO2 level (value*X)" ::= { valuesInt 4 } re1Int OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Relay 1 state" ::= { valuesInt 8 } re2Int OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Relay 2 state" ::= { valuesInt 9 } tempAlarm1Int OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm1 on Temperature" ::= { valuesInt 10 } humAlarm1Int OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm1 on Relative humidity" ::= { valuesInt 11 } compValAlarm1Int OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm1 on Computed value" ::= { valuesInt 12 } co2Alarm1Int OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm1 on CO2 level" ::= { valuesInt 13 } tempAlarm2Int OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm2 on Temperature" ::= { valuesInt 14 } humAlarm2Int OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm2 on Relative humidity" ::= { valuesInt 15 } compValAlarm2Int OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm2 on Computed value" ::= { valuesInt 16 } co2Alarm2Int OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm2 on CO2 level" ::= { valuesInt 17 } ----------------------------------------------------------------------- -- Alarm settings ----------------------------------------------------------------------- tempLim1Int OBJECT-TYPE SYNTAX INTEGER (-5000..20000) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature Alarm1 Limit (value*10)" ::= { settings 1 } humLim1Int OBJECT-TYPE SYNTAX INTEGER (-5000..20000) ACCESS read-only STATUS mandatory DESCRIPTION "Humidity Alarm1 Limit (value*10)" ::= { settings 2 } compValLim1Int OBJECT-TYPE SYNTAX INTEGER (-5000..20000) ACCESS read-only STATUS mandatory DESCRIPTION "Computed Alarm1 Limit (value*10)" ::= { settings 3 } co2Lim1Int OBJECT-TYPE SYNTAX INTEGER (-5000..20000) ACCESS read-only STATUS mandatory DESCRIPTION "CO2 level Alarm1 Limit (value*X)" ::= { settings 4 } tempLim2Int OBJECT-TYPE SYNTAX INTEGER (-5000..20000) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature Alarm2 Limit (value*10)" ::= { settings 5 } humLim2Int OBJECT-TYPE SYNTAX INTEGER (-5000..20000) ACCESS read-only STATUS mandatory DESCRIPTION "Humidity Alarm2 Limit (value*10)" ::= { settings 6 } compValLim2Int OBJECT-TYPE SYNTAX INTEGER (-5000..20000) ACCESS read-only STATUS mandatory DESCRIPTION "Computed value Alarm2 Limit (value*10)" ::= { settings 7 } co2Lim2Int OBJECT-TYPE SYNTAX INTEGER (-5000..20000) ACCESS read-only STATUS mandatory DESCRIPTION "CO2 level Alarm2 Limit (value*X)" ::= { settings 8 } tempHyst1Int OBJECT-TYPE SYNTAX INTEGER (0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature Alarm1 Hysteresis (value*10)" ::= { settings 9 } humHyst1Int OBJECT-TYPE SYNTAX INTEGER (0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "Humidity Alarm1 Hysteresis (value*10)" ::= { settings 10 } compValHyst1Int OBJECT-TYPE SYNTAX INTEGER (0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "Computed value Alarm1 Hysteresis (value*10)" ::= { settings 11 } co2Hyst1Int OBJECT-TYPE SYNTAX INTEGER (0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "CO2 level Alarm1 Hysteresis (value*X)" ::= { settings 12 } tempHyst2Int OBJECT-TYPE SYNTAX INTEGER (0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature Alarm2 Hysteresis (value*10)" ::= { settings 13 } humHyst2Int OBJECT-TYPE SYNTAX INTEGER (0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "Humidity Alarm2 Hysteresis (value*10)" ::= { settings 14 } compValHyst2Int OBJECT-TYPE SYNTAX INTEGER (0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "Computed value Alarm2 Hysteresis (value*10)" ::= { settings 15 } co2Hyst2Int OBJECT-TYPE SYNTAX INTEGER (0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "CO2 level Alarm2 Hysteresis (value*X)" ::= { settings 16 } tempDelay1Int OBJECT-TYPE SYNTAX INTEGER (0..30000) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature Alarm1 Delay [sec]" ::= { settings 17 } humDelay1Int OBJECT-TYPE SYNTAX INTEGER (0..30000) ACCESS read-only STATUS mandatory DESCRIPTION "Humidity Alarm1 Delay [sec]" ::= { settings 18 } compValDelay1Int OBJECT-TYPE SYNTAX INTEGER (0..30000) ACCESS read-only STATUS mandatory DESCRIPTION "Computed value Alarm1 Delay [sec]" ::= { settings 19 } co2Delay1Int OBJECT-TYPE SYNTAX INTEGER (0..30000) ACCESS read-only STATUS mandatory DESCRIPTION "CO2 level Alarm1 Delay [sec]" ::= { settings 20 } tempDelay2Int OBJECT-TYPE SYNTAX INTEGER (0..30000) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature Alarm2 Delay [sec]" ::= { settings 21 } humDelay2Int OBJECT-TYPE SYNTAX INTEGER (0..30000) ACCESS read-only STATUS mandatory DESCRIPTION "Humidity Alarm2 Delay [sec]" ::= { settings 22 } compValDelay2Int OBJECT-TYPE SYNTAX INTEGER (0..30000) ACCESS read-only STATUS mandatory DESCRIPTION "Computed value Alarm2 Delay [sec]" ::= { settings 23 } co2Delay2Int OBJECT-TYPE SYNTAX INTEGER (0..30000) ACCESS read-only STATUS mandatory DESCRIPTION "CO2 level Alarm2 Delay [sec]" ::= { settings 24 } tempType1Int OBJECT-TYPE SYNTAX INTEGER (0..2) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature Alarm1 Type; 0-disbaled, 1-low, 2-high" ::= { settings 25 } humType1Int OBJECT-TYPE SYNTAX INTEGER (0..2) ACCESS read-only STATUS mandatory DESCRIPTION "Humidity Alarm1 Type; 0-disbaled, 1-low, 2-high" ::= { settings 26 } compValType1Int OBJECT-TYPE SYNTAX INTEGER (0..2) ACCESS read-only STATUS mandatory DESCRIPTION "Computed value Alarm1 Type; 0-disbaled, 1-low, 2-high" ::= { settings 27 } co2Type1Int OBJECT-TYPE SYNTAX INTEGER (0..2) ACCESS read-only STATUS mandatory DESCRIPTION "CO2 level Alarm1 Type; 0-disbaled, 1-low, 2-high" ::= { settings 28 } tempType2Int OBJECT-TYPE SYNTAX INTEGER (0..2) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature Alarm2 Type; 0-disbaled, 1-low, 2-high" ::= { settings 29 } humType2Int OBJECT-TYPE SYNTAX INTEGER (0..2) ACCESS read-only STATUS mandatory DESCRIPTION "Humidity Alarm2 Type; 0-disbaled, 1-low, 2-high" ::= { settings 30 } compValType2Int OBJECT-TYPE SYNTAX INTEGER (0..2) ACCESS read-only STATUS mandatory DESCRIPTION "Computed value Alarm2 Type; 0-disbaled, 1-low, 2-high" ::= { settings 31 } co2Type2Int OBJECT-TYPE SYNTAX INTEGER (0..2) ACCESS read-only STATUS mandatory DESCRIPTION "CO2 level Alarm2 Type; 0-disbaled, 1-low, 2-high" ::= { settings 32 } ----------------------------------------------------------------------- -- Trap message ----------------------------------------------------------------------- messageString OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Message giving more detailed information on trap" ::= { traps 1 } ----------------------------------------------------------------------- -- Tables ----------------------------------------------------------------------- historyTable OBJECT-TYPE SYNTAX SEQUENCE OF HistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of the history values" ::= { tables 1 } historyEntry OBJECT-TYPE SYNTAX HistoryEntry ACCESS not-accessible STATUS optional DESCRIPTION "History values entries" INDEX { histTemp } ::= { historyTable 1 } HistoryEntry ::= SEQUENCE { histTemp INTEGER, histHum INTEGER, histCompVal INTEGER, histCO2 INTEGER } histTemp OBJECT-TYPE SYNTAX INTEGER(-5000..20000) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature reading" ::= { historyEntry 1 } histHum OBJECT-TYPE SYNTAX INTEGER(-5000..20000) ACCESS read-only STATUS mandatory DESCRIPTION "Humidity reading" ::= { historyEntry 2 } histCompVal OBJECT-TYPE SYNTAX INTEGER (-5000..20000) ACCESS read-only STATUS mandatory DESCRIPTION "Computed value reading" ::= { historyEntry 3 } histCO2 OBJECT-TYPE SYNTAX INTEGER(-5000..20000) ACCESS read-only STATUS mandatory DESCRIPTION "CO2 level reading" ::= { historyEntry 4 } ----------------------------------------------------------------------- -- Traps definition ----------------------------------------------------------------------- trapTest TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString } DESCRIPTION "Testing trap, testing trap by TSensor software" ::= 0 trapNTPError TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString } DESCRIPTION "Error on time synchronisation via NTP" ::= 1 trapEmailErrLogin TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString } DESCRIPTION "SMTP error - unknown server" ::= 2 trapEmailErrAuth TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString } DESCRIPTION "SMTP error - authentication error" ::= 3 trapEmailErrSome TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString } DESCRIPTION "SMTP error - error during communication with server, unexpected return code" ::= 4 trapEmailErrSocket TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString } DESCRIPTION "SMTP error - socket error, server is not available" ::= 5 trapEmailErrDNS TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString } DESCRIPTION "SMTP error - DNS error" ::= 6 trapSOAPErrFile TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString } DESCRIPTION "SOAP error - file SOAP not found" ::= 7 trapSOAPErrDNS TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString } DESCRIPTION "SOAP error - DNS error" ::= 8 trapSOAPErrSocket TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString } DESCRIPTION "SOAP error - socket error, server is not available" ::= 9 trapSOAPErrDelivery TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString } DESCRIPTION "SOAP error - delivery error, wrong return code from server" ::= 10 trapTempAlarm1 TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, temp, tempAlarm1Int } DESCRIPTION "Trap for alarm1 on Temperature" ::= 11 trapHumAlarm1 TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, hum, humAlarm1Int } DESCRIPTION "Trap for alarm1 on Relative humidity" ::= 12 trapCompValAlarm1 TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, compVal, compValAlarm1Int } DESCRIPTION "Trap for alarm1 on Computed value" ::= 13 trapCO2Alarm1 TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, co2, co2Alarm1Int } DESCRIPTION "Trap for alarm1 on CO2 level" ::= 14 trapTempAlarm2 TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, temp, tempAlarm2Int } DESCRIPTION "Trap for alarm2 on Temperature" ::= 21 trapHumAlarm2 TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, hum, humAlarm2Int } DESCRIPTION "Trap for alarm2 on Relative humidity" ::= 22 trapCompValAlarm2 TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, compVal, compValAlarm2Int } DESCRIPTION "Trap for alarm2 on Computed value" ::= 23 trapCO2Alarm2 TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, co2, co2Alarm2Int } DESCRIPTION "Trap for alarm2 on CO2 level" ::= 24 trapTempClrAlarm1 TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, temp, tempAlarm1Int } DESCRIPTION "Trap for clearing alarm 1 on Temperature" ::= 31 trapHumClrAlarm1 TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, hum, humAlarm1Int } DESCRIPTION "Trap for clearing alarm 1 on Relative humidity" ::= 32 trapCompValClrAlarm1 TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, compVal, compValAlarm1Int } DESCRIPTION "Trap for clearing alarm 1 on Computed value" ::= 33 trapCO2ClrAlarm1 TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, co2, co2Alarm1Int } DESCRIPTION "Trap for clearing alarm 1 on CO2 level" ::= 34 trapTempClrAlarm2 TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, temp, tempAlarm2Int } DESCRIPTION "Trap for clearing alarm 2 on Temperature" ::= 41 trapHumClrAlarm2 TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, hum, humAlarm2Int } DESCRIPTION "Trap for clearing alarm 2 on Relative humidity" ::= 42 trapCompValClrAlarm2 TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, compVal, compValAlarm2Int } DESCRIPTION "Trap for clearing alarm 2 on Computed value" ::= 43 trapCO2ClrAlarm2 TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, co2, co2Alarm2Int } DESCRIPTION "Trap for clearing alarm 2 on CO2 level" ::= 44 trapRelay1Closed TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, re1Int } DESCRIPTION "Trap for closed Relay 1" ::= 70 trapRelay2Closed TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, re2Int } DESCRIPTION "Trap for closed Relay 2" ::= 71 trapRelay1Open TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, re1Int } DESCRIPTION "Trap for open Relay 1" ::= 72 trapRelay2Open TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString, re2Int } DESCRIPTION "Trap for open Relay 2" ::= 73 trapAcousticActivated TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString } DESCRIPTION "Trap for activated acoustic" ::= 74 trapAcousticDeactivated TRAP-TYPE ENTERPRISE comet VARIABLES { sensorName, messageString } DESCRIPTION "Trap for deactivated acoustic" ::= 75 END