CIENA-OME6500-S5-ETH-MULTISEG-TOPOLOGY-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, IpAddress, Integer32, TimeTicks FROM SNMPv2-SMI SnpxChassisType, SnpxBackplaneType FROM SYNOPTICS-ROOT-MIB InetAddress, InetAddressType FROM INET-ADDRESS-MIB DisplayString FROM RFC1213-MIB cienaS5EnMsTop FROM CIENA-OME6500-S5-ROOT-MIB MacAddress FROM SNMPv2-TC; ome6500S5EthMultisegTopologyMib MODULE-IDENTITY LAST-UPDATED "201510200000Z" ORGANIZATION "Ciena Corp" CONTACT-INFO "Ciena Corp" DESCRIPTION "5000 CIENA Ethernet Multi-segment MIB Created for Rel11.10. This MIB contains objects extended from Nortel S5-ETH-MULTISEG-TOPOLOGY MIB." REVISION "201510200000Z" DESCRIPTION "Created for Rel11.10 to enhance support for ipv6 address and LLDP fields." ::= { cienaS5EnMsTop 0 } -- Groups ome6500S5EnMsTopInfo OBJECT IDENTIFIER ::= { cienaS5EnMsTop 1 } ome6500S5EnMsTopNmm OBJECT IDENTIFIER ::= { cienaS5EnMsTop 2 } ome6500S5EnMsTopBdg OBJECT IDENTIFIER ::= { cienaS5EnMsTop 3 } ome6500S5EnMsTopSrcMac OBJECT IDENTIFIER ::= { cienaS5EnMsTop 4 } -- SECTION 2: MIB Objects -- Topology Status and Configuration Information ome6500S5EnMsTopIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "An IP address of the agent. This is used to fill in the IP address field of transmitted SONMP packets. The agent should be reachable through this IP address." ::= { ome6500S5EnMsTopInfo 1 } ome6500S5EnMsTopStatus OBJECT-TYPE SYNTAX INTEGER { topOn(1), topOff(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if the agent is participating in multi-segment topology. The values are: topOn(1)....topology is on topOff(2)...topology is off When the value is topOff(2) the status of topology table entries is undefined. However, the agent should make its best attempt when the value is changed to topOff(2) to remove all existing instances of topology MIB objects. The agent must save the setting of this object in nonvolatile memory (i.e., save across reboots)." DEFVAL { topOn } ::= { ome6500S5EnMsTopInfo 2 } ome6500S5EnMsTopNmmLstChg OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime the last time an entry in the NMM topology table was added, deleted, or modified. If the NMM topology table has not changed since cold/warm start of the agent, then the value is zero." ::= { ome6500S5EnMsTopInfo 3 } ome6500S5EnMsTopBdgLstChg OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The value of sysUpTime the last time an entry in the bridge topology table was added, deleted, or modified. If the bridge topology table has not changed since cold/warm start of the agent, then the value is zero." ::= { ome6500S5EnMsTopInfo 4 } ome6500S5EnMsTopNmmMaxNum OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of entries in the NMM topology table." ::= { ome6500S5EnMsTopInfo 5 } ome6500S5EnMsTopNmmCurNum OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The current number of entries in the NMM topology table." ::= { ome6500S5EnMsTopInfo 6 } ome6500S5EnMsTopBdgMaxNum OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The maximum number of entries in the bridge topology table." ::= { ome6500S5EnMsTopInfo 7 } ome6500S5EnMsTopBdgCurNum OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The current number of entries in the bridge topology table." ::= { ome6500S5EnMsTopInfo 8 } ome6500S5EnMsTopInetAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-only STATUS current DESCRIPTION "The address type of shelf.Currently only unknown and ipv6 values are expected. Value unknown will be returned if no ipv6 address is provisioned." ::= { ome6500S5EnMsTopInfo 9 } ome6500S5EnMsTopInetAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is Shelf's network address. Its value depends on the value of ome6500S5EnMsTopInetAddressType NULL value will be returned in case no ipv6 address is provisioned." ::= { ome6500S5EnMsTopInfo 10 } -- Network Management Module (NMM) Topology Table ome6500S5EnMsTopNmmTable OBJECT-TYPE SYNTAX SEQUENCE OF Ome6500S5EnMsTopNmmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of topology information from each topology agent that sends out NMM topology messages, and that has been heard by the reporting topology agent. The number of entries is determined by the number of distinct topology messages received. A topology message is identified by a combination of the IP address and segment-identifier contained in the message, and the slot-port on which it is received. Entries in the table are created by reception of a 'new' NMM topology message. An entry is removed from the table after no messages are received from the corresponding topology agent in the required time interval. NOTE: there is an entry for the reporting agent with the values of slot and port set to zero." ::= { ome6500S5EnMsTopNmm 1 } ome6500S5EnMsTopNmmEntry OBJECT-TYPE SYNTAX Ome6500S5EnMsTopNmmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the NMM topology table. Entries in the table can not be created or deleted via SNMP." INDEX { ome6500S5EnMsTopNmmSlot, ome6500S5EnMsTopNmmPort, ome6500S5EnMsTopNmmIpAddr, ome6500S5EnMsTopNmmSegId } ::= { ome6500S5EnMsTopNmmTable 1 } Ome6500S5EnMsTopNmmEntry ::= SEQUENCE { ome6500S5EnMsTopNmmSlot INTEGER, ome6500S5EnMsTopNmmPort INTEGER, ome6500S5EnMsTopNmmIpAddr IpAddress, ome6500S5EnMsTopNmmSegId INTEGER, ome6500S5EnMsTopNmmMacAddr MacAddress, ome6500S5EnMsTopNmmChassisType SnpxChassisType, ome6500S5EnMsTopNmmBkplType SnpxBackplaneType, ome6500S5EnMsTopNmmLocalSeg INTEGER, ome6500S5EnMsTopNmmCurState INTEGER, ome6500S5EnMsTopNmmInetAddressType InetAddressType, ome6500S5EnMsTopNmmInetAddress InetAddress, ome6500S5EnMsTopNmmSystemDescr DisplayString, ome6500S5EnMsTopNmmPortString DisplayString, ome6500S5EnMsTopNmmRxActualData DisplayString } ome6500S5EnMsTopNmmSlot OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The slot on which the topology message was received. NOTE: There is an artificial 'row' for the reporting agent with slot and port equal to zero. NOTE: Non-modular devices that do not have multiple slots should set this value to 1." ::= { ome6500S5EnMsTopNmmEntry 1 } ome6500S5EnMsTopNmmPort OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The port on which the topology message was received. NOTE: there is an artificial 'row' for the reporting agent with slot and port equal to zero." ::= { ome6500S5EnMsTopNmmEntry 2 } ome6500S5EnMsTopNmmIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the sender of the topology message." ::= { ome6500S5EnMsTopNmmEntry 3 } ome6500S5EnMsTopNmmSegId OBJECT-TYPE SYNTAX INTEGER (0..'FFFFFF'H) MAX-ACCESS read-only STATUS current DESCRIPTION "The 'segment identifier' of the segment from which the remote agent sent the topology message. The value is extracted from the received topology message. Different devices may use different methods for representing the segment identifier. For example, system 5000 NMMs that run multi-segment autotopology use the SrcIndx of the segment as the segment identifier; switches use a computed a value equal to '(256 * s) + p' where 's' is the board, card or slot number and 'p' is the port number on and as seen by the switch sending the topology message; system 3000 NMMs use the lower three bytes of the MAC address of the NMM as the segment identifier. In any case, the 'segment identifier' uniquely identifies the network segment in the remote device from which the topology message was sent." ::= { ome6500S5EnMsTopNmmEntry 4 } ome6500S5EnMsTopNmmMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The MAC address of the sender of the topology message." ::= { ome6500S5EnMsTopNmmEntry 5 } ome6500S5EnMsTopNmmChassisType OBJECT-TYPE SYNTAX SnpxChassisType MAX-ACCESS read-only STATUS current DESCRIPTION "The chassis type of the device that sent the topology message." ::= { ome6500S5EnMsTopNmmEntry 6 } ome6500S5EnMsTopNmmBkplType OBJECT-TYPE SYNTAX SnpxBackplaneType MAX-ACCESS read-only STATUS current DESCRIPTION "The backplane type of the device that sent the topology message." ::= { ome6500S5EnMsTopNmmEntry 7 } ome6500S5EnMsTopNmmLocalSeg OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if the sender of the topology message is on the same Ethernet segment (i.e., NOT across a bridge) as the reporting agent." ::= { ome6500S5EnMsTopNmmEntry 8 } ome6500S5EnMsTopNmmCurState OBJECT-TYPE SYNTAX INTEGER { topChanged(1), heartbeat(2), new(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of sender of the topology message. The values are: topChanged(1)...topology information has recently changed heartbeat(2)....topology information unchanged new(3)..........sending agent is in new state." ::= { ome6500S5EnMsTopNmmEntry 9 } ome6500S5EnMsTopNmmInetAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-only STATUS current DESCRIPTION "The address type of shelf.Currently only unknown and ipv6 values are expected. Value unknown will be returned if no ipv6 address is provisioned." ::= { ome6500S5EnMsTopNmmEntry 10 } ome6500S5EnMsTopNmmInetAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is Shelf's network address. Its value depends on the value of object ome6500S5EnMsTopNmmInetAddressType." ::= { ome6500S5EnMsTopNmmEntry 11 } ome6500S5EnMsTopNmmSystemDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is system_description string. Its max length shall be always 40 characters." ::= { ome6500S5EnMsTopNmmEntry 12 } ome6500S5EnMsTopNmmPortString OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is Port String value from LLDP data. Its max length shall be 12 characters." ::= { ome6500S5EnMsTopNmmEntry 13 } ome6500S5EnMsTopNmmRxActualData OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is the String containing LLDP information received in Rx_Actual field. This will contain the complete information for LLDP output." ::= { ome6500S5EnMsTopNmmEntry 14 } -- Encoded Octet Strings for NMM Topology Table ome6500S5EnMsTopNmmEosSize OBJECT-TYPE SYNTAX INTEGER (0..1440) MAX-ACCESS read-only STATUS current DESCRIPTION "The current size of a 'row' in the table ome6500S5EnMsTopNmmEosTable. This allows applications to be able to break apart 'rows' in the table." ::= { ome6500S5EnMsTopNmm 2 } ome6500S5EnMsTopNmmEosTable OBJECT-TYPE SYNTAX SEQUENCE OF Ome6500S5EnMsTopNmmEosEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of encoded octet strings of entries in table ome6500S5EnMsTopNmmTable. The number of entries is determined by packing of 'rows' from ome6500S5EnMsTopNmmTable." ::= { ome6500S5EnMsTopNmm 3 } ome6500S5EnMsTopNmmEosEntry OBJECT-TYPE SYNTAX Ome6500S5EnMsTopNmmEosEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the table of encoded octet strings for table ome6500S5EnMsTopNmmTable. Instance returned in Response PDU: On GETs: instance specified is the instance returned. On GET-NEXTs: instance returned is the instance of the last record contained in the octet string. Entries in the table can not be created or deleted via SNMP." INDEX { ome6500S5EnMsTopNmmSlot, ome6500S5EnMsTopNmmPort, ome6500S5EnMsTopNmmIpAddr, ome6500S5EnMsTopNmmSegId } ::= { ome6500S5EnMsTopNmmEosTable 1 } Ome6500S5EnMsTopNmmEosEntry ::= SEQUENCE { ome6500S5EnMsTopNmmEos OCTET STRING } ome6500S5EnMsTopNmmEos OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..1400)) MAX-ACCESS read-only STATUS current DESCRIPTION "An encoded octet string. On reads it contains an integral number of 'rows' from table ome6500S5EnMsTopNmmTable. All 'rows' are the same size which is defined by object ome6500S5EnMsTopNmmEosSize." ::= { ome6500S5EnMsTopNmmEosEntry 1 } -- Bridge Topology Table ome6500S5EnMsTopBdgTable OBJECT-TYPE SYNTAX SEQUENCE OF Ome6500S5EnMsTopBdgEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A table of topology information from each Bridge in the network that is sending bridge topology messages that have been heard by the reporting agent. The number of entries is determined by the number of detected (and active) bridges. Entries in the table are created by reception of a topology message from a 'new' bridge. An entry is removed from the table after no messages are received from the corresponding bridge in the required time interval." ::= { ome6500S5EnMsTopBdg 1 } ome6500S5EnMsTopBdgEntry OBJECT-TYPE SYNTAX Ome6500S5EnMsTopBdgEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A row in the bridge topology table. Entries in the table can not be created or deleted via SNMP." INDEX { ome6500S5EnMsTopBdgSlotNum, ome6500S5EnMsTopBdgPortNum, ome6500S5EnMsTopBdgIpAddr } ::= { ome6500S5EnMsTopBdgTable 1 } Ome6500S5EnMsTopBdgEntry ::= SEQUENCE { ome6500S5EnMsTopBdgSlotNum INTEGER, ome6500S5EnMsTopBdgPortNum INTEGER, ome6500S5EnMsTopBdgIpAddr IpAddress, ome6500S5EnMsTopBdgNumber INTEGER, ome6500S5EnMsTopBdgMacAddr MacAddress, ome6500S5EnMsTopBdgType INTEGER, ome6500S5EnMsTopBdgStatus INTEGER, ome6500S5EnMsTopBdgNumPorts Integer32, ome6500S5EnMsTopBdgHelloPortNum INTEGER, ome6500S5EnMsTopBdgHelloPortType INTEGER, ome6500S5EnMsTopBdgHelloPortStatus INTEGER, ome6500S5EnMsTopBdgCompBdgMac1 MacAddress, ome6500S5EnMsTopBdgCompBdgMac2 MacAddress } ome6500S5EnMsTopBdgSlotNum OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The slot on which the topology message was received. NOTE: Non-modular devices that do not have multiple slots should set this value to 1." ::= { ome6500S5EnMsTopBdgEntry 1 } ome6500S5EnMsTopBdgPortNum OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The port on which the topology message was received." ::= { ome6500S5EnMsTopBdgEntry 2 } ome6500S5EnMsTopBdgIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The IP address of the bridge that sent the topology message." ::= { ome6500S5EnMsTopBdgEntry 3 } ome6500S5EnMsTopBdgNumber OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The 'Bridge Number' of the bridge that sent the topology message. This is the IEEE 802.1 bridge number." ::= { ome6500S5EnMsTopBdgEntry 4 } ome6500S5EnMsTopBdgMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The MAC Address of the bridge that sent the topology message." ::= { ome6500S5EnMsTopBdgEntry 5 } ome6500S5EnMsTopBdgType OBJECT-TYPE SYNTAX INTEGER { other(1), localSyn(2), remoteSyn(3), kalpana(4) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The 'kind of bridge' that sent the topology message. The values are: other(1).....unknown or other type locSyn(2)....local SynOptics bridge remSyn(3)....remote SynOptics bridge kalpana(4)...Kalpana bridge(switch) " ::= { ome6500S5EnMsTopBdgEntry 6 } ome6500S5EnMsTopBdgNumPorts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The number of ports on the bridge." ::= { ome6500S5EnMsTopBdgEntry 7 } ome6500S5EnMsTopBdgStatus OBJECT-TYPE SYNTAX INTEGER { other(1), active(2), standby(3) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The current operational status from the bridge that sent the topology message. The values are: other(1).....unknown or other active(2)....bridge is active standby(3)...bridge is in standby A value of standby(3) means that at least ONE port is in standby mode. A value of active(2) means NO port is in standby mode." ::= { ome6500S5EnMsTopBdgEntry 8 } ome6500S5EnMsTopBdgHelloPortNum OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The port number used by the bridge to send the topology message. This port may or may not be in standby mode." ::= { ome6500S5EnMsTopBdgEntry 9 } ome6500S5EnMsTopBdgHelloPortType OBJECT-TYPE SYNTAX INTEGER { other(1), eth(2), tok4(3), tok16(4), fddi(5), t1(6) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The type of the port used by the bridge to send the topology message. The values are: other(1)...other or unknown type eth(2).....ethernet tok4(3)....4 Mbit token ring tok16(4)...16 Mbit token ring fddi(5)....fddi t1(6)......t1 Note: These enumerations were done for 'completeness'. No other value than eth(2) should ever be received by an ethernet agent." ::= { ome6500S5EnMsTopBdgEntry 10 } ome6500S5EnMsTopBdgHelloPortStatus OBJECT-TYPE SYNTAX INTEGER { other(1), active(2), standby(3) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The status of the port used by the bridge to send the topology message. The values are: other(1).....unknown or other active(2)....port is active standby(3)...port is in standby" ::= { ome6500S5EnMsTopBdgEntry 11 } ome6500S5EnMsTopBdgCompBdgMac1 OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The first MAC address of a companion bridge of the bridge that sent the topology message. The value is 00:00:00:00:00:00 for local bridges (since there is no companion bridge) and also when the companion MAC address is unknown for remote bridges." ::= { ome6500S5EnMsTopBdgEntry 12 } ome6500S5EnMsTopBdgCompBdgMac2 OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The second MAC address of a companion bridge of the bridge that sent the topology message. The value is 00:00:00:00:00:00 for local bridges (since there is no companion bridge) and also when the companion MAC address is unknown for remote bridges." ::= { ome6500S5EnMsTopBdgEntry 13 } -- Encoded Octet Strings for Bridge Topology Table ome6500S5EnMsTopBdgEosSize OBJECT-TYPE SYNTAX INTEGER (0..1440) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The current size of a 'row' in the table ome6500S5EnMsTopBdgEosTable. This allows applications to be able to break apart 'rows' in the table." ::= { ome6500S5EnMsTopBdg 2 } ome6500S5EnMsTopBdgEosTable OBJECT-TYPE SYNTAX SEQUENCE OF Ome6500S5EnMsTopBdgEosEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A table of encoded octet strings of entries in table ome6500S5EnMsTopBdgTable. The number of entries is determined by packing of 'rows' from ome6500S5EnMsTopBdgTable." ::= { ome6500S5EnMsTopBdg 3 } ome6500S5EnMsTopBdgEosEntry OBJECT-TYPE SYNTAX Ome6500S5EnMsTopBdgEosEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A row in the table of encoded octet strings for table ome6500S5EnMsTopBdgTable. Instance returned in Response PDU: On GETs: instance specified is the instance returned. On GET-NEXTs: instance returned is the instance of the last record contained in the octet string. Entries in the table can not be created or deleted via SNMP." INDEX { ome6500S5EnMsTopBdgSlotNum, ome6500S5EnMsTopBdgPortNum, ome6500S5EnMsTopBdgIpAddr } ::= { ome6500S5EnMsTopBdgEosTable 1 } Ome6500S5EnMsTopBdgEosEntry ::= SEQUENCE { ome6500S5EnMsTopBdgEos OCTET STRING } ome6500S5EnMsTopBdgEos OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..1400)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "An encoded octet string. On reads it contains an integral number of 'rows' from table ome6500S5EnMsTopBdgTable. All 'rows' are the same size which is defined by object ome6500S5EnMsTopBdgEosSize." ::= { ome6500S5EnMsTopBdgEosEntry 1 } -- MAC Address-to-Segment Mapping Table -- Implementation of this group is optional. It is supported by those -- devices that use different source MAC addresses to transmit -- topology messages on different segments. ome6500S5EnMsTopSrcMacAddrTable OBJECT-TYPE SYNTAX SEQUENCE OF Ome6500S5EnMsTopSrcMacAddrEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A table describing the source MAC addresses that the agent uses to transmit topology messages on different segments in the device. The MAC addresses are preallocated and remain unchanged for the agent. However, the mapping between a MAC address and segment may change, since it can depend on the current physical and/or logical configuration of the device. Implementation of this group is required for those devices that use different source MAC addresses to transmit topology messages on different segments. Implementation of this group is optional otherwise." ::= { ome6500S5EnMsTopSrcMac 1 } ome6500S5EnMsTopSrcMacAddrEntry OBJECT-TYPE SYNTAX Ome6500S5EnMsTopSrcMacAddrEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A row in the table of MAC address-to-segment mappings. Entries in the table can not be created or deleted via SNMP." INDEX { ome6500S5EnMsTopSrcMacAddr } ::= { ome6500S5EnMsTopSrcMacAddrTable 1 } Ome6500S5EnMsTopSrcMacAddrEntry ::= SEQUENCE { ome6500S5EnMsTopSrcMacAddr MacAddress, ome6500S5EnMsTopSrcMacSegId INTEGER } ome6500S5EnMsTopSrcMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The MAC address used to transmit topology messages." ::= { ome6500S5EnMsTopSrcMacAddrEntry 1 } ome6500S5EnMsTopSrcMacSegId OBJECT-TYPE SYNTAX INTEGER (0..16777215) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The 'segment-identifier' of the segment on which topology messages were transmitted." ::= { ome6500S5EnMsTopSrcMacAddrEntry 2 } ome6500S5EnMsTopSrcMacAddrLstChg OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The value of sysUpTime when an entry in the table ome6500S5EnMsTopSrcMacAddrTable was last changed. If no changes have been done since cold/warm start of the agent, then the value is zero." ::= { ome6500S5EnMsTopSrcMac 2 } END