-- -- CAREL-uac.MIB -- MIB generated by CAREL -- Friday, 14 March 2003 -- CAREL-uac-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-GROUP FROM SNMPv2-CONF sysContact, sysName, sysLocation FROM SNMPv2-MIB enterprises, MODULE-IDENTITY FROM SNMPv2-SMI; uacMIB MODULE-IDENTITY LAST-UPDATED "200303141725Z" -- March 14, 2003 at 17:25 GMT ORGANIZATION "CAREL SpA" CONTACT-INFO " Simone Ravazzolo Carel SpA Via dell'Industria, 11 35020 Brugine (PD) Italy Tel: +39 049 9716611 E-mail: simone.ravazzolo@carel.com " DESCRIPTION "This is the MIB module for the uac device." ::= { instruments 1 } -- -- Node definitions -- -- 1.3.6.1.4.1.9839 carel OBJECT IDENTIFIER ::= { enterprises 9839 } -- 1.3.6.1.4.1.9839.1 systm OBJECT IDENTIFIER ::= { carel 1 } -- 1.3.6.1.4.1.9839.1.1 agentRelease OBJECT-TYPE SYNTAX Integer32 UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Release of the Agent." ::= { systm 1 } -- 1.3.6.1.4.1.9839.1.2 agentCode OBJECT-TYPE SYNTAX Integer32 UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Code of the Agent. 1=WebGate" ::= { systm 2 } -- 1.3.6.1.4.1.9839.2 instruments OBJECT IDENTIFIER ::= { carel 2 } -- 1.3.6.1.4.1.9839.2.0 webGateInfo OBJECT IDENTIFIER ::= { instruments 0 } -- 1.3.6.1.4.1.9839.2.0.1 agentParameters OBJECT IDENTIFIER ::= { webGateInfo 1 } -- 1.3.6.1.4.1.9839.2.0.1.1 netSize OBJECT-TYPE SYNTAX Integer32 (1..16) UNITS "N/A" MAX-ACCESS read-write STATUS current DESCRIPTION "Network size. It corresponds to the number of units connected to the WebGate. " ::= { agentParameters 1 } -- 1.3.6.1.4.1.9839.2.0.1.2 baudRate OBJECT-TYPE SYNTAX Integer32 (1200 | 2400 |4800 |9600 | 19200) UNITS "N/A" MAX-ACCESS read-write STATUS current DESCRIPTION "Baudrate of the Carel network. " ::= { agentParameters 2 } -- 1.3.6.1.4.1.9839.2.0.2 unitTypeGroup OBJECT IDENTIFIER ::= { webGateInfo 2 } -- 1.3.6.1.4.1.9839.2.0.2.1 unit1-Type OBJECT-TYPE SYNTAX DisplayString UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the unit having serial address 1. " ::= { unitTypeGroup 1 } -- ... You will have how many unitX-Type objects as the value of netSize is -- 1.3.6.1.4.1.9839.2.0.3 unitCodeGroup OBJECT IDENTIFIER ::= { webGateInfo 3 } -- 1.3.6.1.4.1.9839.2.0.3.1 unit1-Code OBJECT-TYPE SYNTAX Integer32 UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Code of the unit having serial address 1. " ::= { unitCodeGroup 1 } -- ... You will have how many unitX-Code objects as the value of netSize is -- 1.3.6.1.4.1.9839.2.0.4 unitSoftwareReleaseGroup OBJECT IDENTIFIER ::= { webGateInfo 4 } -- 1.3.6.1.4.1.9839.2.0.3.1 unit1-SoftwareRelease OBJECT-TYPE SYNTAX Integer32 UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Software release of the unit having serial address 1. " ::= { unitSoftwareReleaseGroup 1 } -- ... You will have how many unitX-SoftwareRelease objects as the value of netSize is -- 1.3.6.1.4.1.9839.2.0.5 unitMinSoftwareReleaseGroup OBJECT IDENTIFIER ::= { webGateInfo 5 } -- 1.3.6.1.4.1.9839.2.0.5.1 unit1-MinSoftwareRelease OBJECT-TYPE SYNTAX Integer32 UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum software release of the unit having serial address 1. " ::= { unitMinSoftwareReleaseGroup 1 } -- ... You will have how many unitX-MinSoftwareRelease objects as the value of netSize is -- 1.3.6.1.4.1.9839.2.0.6 unitMaxSoftwareReleaseGroup OBJECT IDENTIFIER ::= { webGateInfo 6 } -- 1.3.6.1.4.1.9839.2.0.6.1 unit1-MaxSoftwareRelease OBJECT-TYPE SYNTAX Integer32 UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum software release of the unit having serial address 1. " ::= { unitMaxSoftwareReleaseGroup 1 } -- ... You will have how many unitX-MaxSoftwareRelease objects as the value of netSize is -- 1.3.6.1.4.1.9839.2.0.7 unitNoAnswerCounterGroup OBJECT IDENTIFIER ::= { webGateInfo 7 } -- 1.3.6.1.4.1.9839.2.0.7.1 unit1-NoAnswerCounter OBJECT-TYPE SYNTAX Integer32 UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "No answer counter of the unit having serial address 1. " ::= { unitNoAnswerCounterGroup 1 } -- ... You will have how many unitX-NoAnswerCounter objects as the value of netSize is -- 1.3.6.1.4.1.9839.2.0.8 unitErrorChecksumCounterGroup OBJECT IDENTIFIER ::= { webGateInfo 8 } -- 1.3.6.1.4.1.9839.2.0.8.1 unit1-ErrorChecksumCounter OBJECT-TYPE SYNTAX Integer32 UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Error checksum counter of the unit having serial address 1. " ::= { unitErrorChecksumCounterGroup 1 } -- ... You will have how many unitX-ErrorChecksumCounter objects as the value of netSize is -- 1.3.6.1.4.1.9839.2.0.9 unitTimeoutCounterGroup OBJECT IDENTIFIER ::= { webGateInfo 9 } -- 1.3.6.1.4.1.9839.2.0.9.1 unit1-TimeoutCounter OBJECT-TYPE SYNTAX Integer32 UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Timeout counter of the unit having serial address 1. " ::= { unitTimeoutCounterGroup 1 } -- ... You will have how many unitX-TimeoutCounter objects as the value of netSize is -- 1.3.6.1.4.1.9839.2.0.10 unitOnLineStatusGroup OBJECT IDENTIFIER ::= { webGateInfo 10 } -- 1.3.6.1.4.1.9839.2.0.10.1 unit1-OnLineStatus OBJECT-TYPE SYNTAX Integer32 UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "On line status of the unit having serial address 1. " ::= { unitOnLineStatusGroup 1 } -- ... You will have how many unitX-OnLineStatus objects as the value of netSize is -- 1.3.6.1.4.1.9839.2.1 uacMIB OBJECT IDENTIFIER ::= { instruments 1 } -- 1.3.6.1.4.1.9839.2.1.1 digitalObjects OBJECT IDENTIFIER ::= { uacMIB 1 } -- 1.3.6.1.4.1.9839.2.1.1.3 al_eeprom OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "eeprom error" ::= { digitalObjects 3 } -- 1.3.6.1.4.1.9839.2.1.1.4 al_b1_ko OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Control sensor faulty or not connected" ::= { digitalObjects 4 } -- 1.3.6.1.4.1.9839.2.1.1.5 al_b2_ko OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Evaporator sensor faulty or not connected" ::= { digitalObjects 5 } -- 1.3.6.1.4.1.9839.2.1.1.6 al_b3_ko OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Humidity probe faulty or not connected" ::= { digitalObjects 6 } -- 1.3.6.1.4.1.9839.2.1.1.7 al_b4_ko OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Supply sensor faulty or not connected" ::= { digitalObjects 7 } -- 1.3.6.1.4.1.9839.2.1.1.8 al_clock OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "clock board faulty or not connected" ::= { digitalObjects 8 } -- 1.3.6.1.4.1.9839.2.1.1.9 al_hp_ckt1 OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "high pressure on circuit 1" ::= { digitalObjects 9 } -- 1.3.6.1.4.1.9839.2.1.1.10 al_hp_ckt2 OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "high pressure on circuit 2" ::= { digitalObjects 10 } -- 1.3.6.1.4.1.9839.2.1.1.11 al_lp_ckt1 OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "low pressure on circuit 1" ::= { digitalObjects 11 } -- 1.3.6.1.4.1.9839.2.1.1.12 al_lp_ckt2 OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "low pressure on circuit 2" ::= { digitalObjects 12 } -- 1.3.6.1.4.1.9839.2.1.1.13 al_flow_sw OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Air flow alarm" ::= { digitalObjects 13 } -- 1.3.6.1.4.1.9839.2.1.1.14 al_clogged_fl OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "clogged filter" ::= { digitalObjects 14 } -- 1.3.6.1.4.1.9839.2.1.1.15 al_heaters_ol OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Resistors overheat" ::= { digitalObjects 15 } -- 1.3.6.1.4.1.9839.2.1.1.16 al_fan_ol OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Fan overheat" ::= { digitalObjects 16 } -- 1.3.6.1.4.1.9839.2.1.1.17 al_comp_ol OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Compressor overheat" ::= { digitalObjects 17 } -- 1.3.6.1.4.1.9839.2.1.1.18 al_freecool OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Cooling alarm" ::= { digitalObjects 18 } -- 1.3.6.1.4.1.9839.2.1.1.19 al_humidif OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Humidifier alarm" ::= { digitalObjects 19 } -- 1.3.6.1.4.1.9839.2.1.1.20 al_room_lt OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "room low temperature" ::= { digitalObjects 20 } -- 1.3.6.1.4.1.9839.2.1.1.21 al_room_ht OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "room high temperature" ::= { digitalObjects 21 } -- 1.3.6.1.4.1.9839.2.1.1.22 al_room_lh OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "room low humidity" ::= { digitalObjects 22 } -- 1.3.6.1.4.1.9839.2.1.1.23 al_room_hh OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "room high humidity" ::= { digitalObjects 23 } -- 1.3.6.1.4.1.9839.2.1.1.24 al_generic_ext OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "External alarm" ::= { digitalObjects 24 } -- 1.3.6.1.4.1.9839.2.1.1.25 al_fan_maint OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "fan maintenance" ::= { digitalObjects 25 } -- 1.3.6.1.4.1.9839.2.1.1.26 al_filter_maint OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "air filter maintenance" ::= { digitalObjects 26 } -- 1.3.6.1.4.1.9839.2.1.1.27 al_comp1_maint OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "compressor n°1 maintenance" ::= { digitalObjects 27 } -- 1.3.6.1.4.1.9839.2.1.1.28 al_comp2_maint OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "compressor n°2 maintenance" ::= { digitalObjects 28 } -- 1.3.6.1.4.1.9839.2.1.1.29 al_low_c_ee OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "low voltage while eeprom writing" ::= { digitalObjects 29 } -- 1.3.6.1.4.1.9839.2.1.1.30 al_volt_lack OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "No shelter mains" ::= { digitalObjects 30 } -- 1.3.6.1.4.1.9839.2.1.1.31 al_smoke_fire OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Smoke/Fire alarm" ::= { digitalObjects 31 } -- 1.3.6.1.4.1.9839.2.1.1.33 unit_status OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "On status" ::= { digitalObjects 33 } -- 1.3.6.1.4.1.9839.2.1.1.34 comp1_status OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Compressor 1" ::= { digitalObjects 34 } -- 1.3.6.1.4.1.9839.2.1.1.35 comp2_status OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Compressor 2" ::= { digitalObjects 35 } -- 1.3.6.1.4.1.9839.2.1.1.36 heater1_status OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-write STATUS current DESCRIPTION "Heater 1" ::= { digitalObjects 36 } -- 1.3.6.1.4.1.9839.2.1.1.37 heater2_status OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-write STATUS current DESCRIPTION "Heater 2" ::= { digitalObjects 37 } -- 1.3.6.1.4.1.9839.2.1.1.38 fan_status OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Fan status" ::= { digitalObjects 38 } -- 1.3.6.1.4.1.9839.2.1.1.39 deshum_status OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Dehumidifier" ::= { digitalObjects 39 } -- 1.3.6.1.4.1.9839.2.1.1.41 humid_on OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-write STATUS current DESCRIPTION "with HA=4,5 humidifier status" ::= { digitalObjects 41 } -- 1.3.6.1.4.1.9839.2.1.1.45 al_fan1_ol OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Fan overheat 1" ::= { digitalObjects 45 } -- 1.3.6.1.4.1.9839.2.1.1.46 al_fan2_ol OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Fan overheat 2" ::= { digitalObjects 46 } -- 1.3.6.1.4.1.9839.2.1.1.49 on_off OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "N/A" MAX-ACCESS read-write STATUS current DESCRIPTION "On/off command (like press on/off key)" ::= { digitalObjects 49 } -- 1.3.6.1.4.1.9839.2.1.1.50 measunit OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Measure unit (celsius/Fahrenheit)" DEFVAL { 0 } ::= { digitalObjects 50 } -- 1.3.6.1.4.1.9839.2.1.2 analogObjects OBJECT IDENTIFIER ::= { uacMIB 2 } -- 1.3.6.1.4.1.9839.2.1.2.1 probeb3_rp OBJECT-TYPE SYNTAX Integer32 (-32767..32767) UNITS "%RH x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Reading probe B3" ::= { analogObjects 1 } -- 1.3.6.1.4.1.9839.2.1.2.2 probeb1_rn OBJECT-TYPE SYNTAX Integer32 (-32767..32767) UNITS "°C x10" MAX-ACCESS read-only STATUS current DESCRIPTION "Room temper. B1" ::= { analogObjects 2 } -- 1.3.6.1.4.1.9839.2.1.2.3 probeb2_ro OBJECT-TYPE SYNTAX Integer32 (-32767..32767) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Reading probe B2" ::= { analogObjects 3 } -- 1.3.6.1.4.1.9839.2.1.2.4 probeb4_rr OBJECT-TYPE SYNTAX Integer32 (-32767..32767) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Reading probe B4" ::= { analogObjects 4 } -- 1.3.6.1.4.1.9839.2.1.2.5 real_setp OBJECT-TYPE SYNTAX Integer32 (-32767..32767) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Set point" DEFVAL { 200 } ::= { analogObjects 5 } -- 1.3.6.1.4.1.9839.2.1.2.11 sum_setp_r1 OBJECT-TYPE SYNTAX Integer32 (-32767..32767) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Temperature set point (cooling)" DEFVAL { 200 } ::= { analogObjects 11 } -- 1.3.6.1.4.1.9839.2.1.2.12 win_setp_r9 OBJECT-TYPE SYNTAX Integer32 (-32767..32767) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Temperature set point (heating)" DEFVAL { 180 } ::= { analogObjects 12 } -- 1.3.6.1.4.1.9839.2.1.2.13 min_setp_t_ra OBJECT-TYPE SYNTAX Integer32 (-40..32767) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum temperature set point" DEFVAL { 0 } ::= { analogObjects 13 } -- 1.3.6.1.4.1.9839.2.1.2.14 max_setp_t_rb OBJECT-TYPE SYNTAX Integer32 (-32767..1400) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum temperature set point" DEFVAL { 500 } ::= { analogObjects 14 } -- 1.3.6.1.4.1.9839.2.1.2.15 sum_diff_r2 OBJECT-TYPE SYNTAX Integer32 (1..198) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Cooling differential" DEFVAL { 30 } ::= { analogObjects 15 } -- 1.3.6.1.4.1.9839.2.1.2.16 win_diff_r3 OBJECT-TYPE SYNTAX Integer32 (1..198) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Heating differential" DEFVAL { 20 } ::= { analogObjects 16 } -- 1.3.6.1.4.1.9839.2.1.2.17 n_zone_r4 OBJECT-TYPE SYNTAX Integer32 (1..360) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Temperature dead zone" DEFVAL { 10 } ::= { analogObjects 17 } -- 1.3.6.1.4.1.9839.2.1.2.18 hum_setp_r5 OBJECT-TYPE SYNTAX Integer32 (-32767..32767) UNITS "%RH x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Humidity Set Point" DEFVAL { 500 } ::= { analogObjects 18 } -- 1.3.6.1.4.1.9839.2.1.2.19 min_setp_h_rc OBJECT-TYPE SYNTAX Integer32 (0..32767) UNITS "%RH x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum humidity set point" DEFVAL { 0 } ::= { analogObjects 19 } -- 1.3.6.1.4.1.9839.2.1.2.20 max_setp_h_rd OBJECT-TYPE SYNTAX Integer32 (-32767..1000) UNITS "%RH x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum humidity set point" DEFVAL { 1000 } ::= { analogObjects 20 } -- 1.3.6.1.4.1.9839.2.1.2.21 diff_hum_r6 OBJECT-TYPE SYNTAX Integer32 (10..200) UNITS "%RH x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Humidification differential" DEFVAL { 40 } ::= { analogObjects 21 } -- 1.3.6.1.4.1.9839.2.1.2.22 diff_dehum_r7 OBJECT-TYPE SYNTAX Integer32 (10..200) UNITS "%RH x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Dehumidification differential" DEFVAL { 30 } ::= { analogObjects 22 } -- 1.3.6.1.4.1.9839.2.1.2.23 n_zone_h_r8 OBJECT-TYPE SYNTAX Integer32 (0..200) UNITS "%RH x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Humidity control dead zone" DEFVAL { 20 } ::= { analogObjects 23 } -- 1.3.6.1.4.1.9839.2.1.2.24 authority_rg OBJECT-TYPE SYNTAX Integer32 (-20..20) UNITS "N/A" MAX-ACCESS read-write STATUS current DESCRIPTION "rG Authority for compensation" DEFVAL { 5 } ::= { analogObjects 24 } -- 1.3.6.1.4.1.9839.2.1.2.25 s_setp_b2_rh OBJECT-TYPE SYNTAX Integer32 (-40..1400) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Cooling set point compensation" DEFVAL { 250 } ::= { analogObjects 25 } -- 1.3.6.1.4.1.9839.2.1.2.26 w_setp_b2_ri OBJECT-TYPE SYNTAX Integer32 (-40..1400) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Heating set point compensation" DEFVAL { 100 } ::= { analogObjects 26 } -- 1.3.6.1.4.1.9839.2.1.2.27 diff_freec_rl OBJECT-TYPE SYNTAX Integer32 (0..540) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Free cooling differential(only for shelters)" DEFVAL { 90 } ::= { analogObjects 27 } -- 1.3.6.1.4.1.9839.2.1.2.28 min_t_freec_rn OBJECT-TYPE SYNTAX Integer32 (-40..860) UNITS "°C x10" MAX-ACCESS read-only STATUS current DESCRIPTION "Lower supply temperature limit during free cooling" DEFVAL { 50 } ::= { analogObjects 28 } -- 1.3.6.1.4.1.9839.2.1.2.29 delta_p6 OBJECT-TYPE SYNTAX Integer32 (0..900) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Delta from effective set point for low temperature alarm" DEFVAL { 100 } ::= { analogObjects 29 } -- 1.3.6.1.4.1.9839.2.1.2.30 delta_p7 OBJECT-TYPE SYNTAX Integer32 (0..900) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Delta from effective set point for high temperature alarm" DEFVAL { 100 } ::= { analogObjects 30 } -- 1.3.6.1.4.1.9839.2.1.2.31 delta_p8 OBJECT-TYPE SYNTAX Integer32 (0..500) UNITS "%RH x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Delta from set point for low humidity alarm" DEFVAL { 200 } ::= { analogObjects 31 } -- 1.3.6.1.4.1.9839.2.1.2.32 delta_p9 OBJECT-TYPE SYNTAX Integer32 (0..500) UNITS "%RH x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Delta from set point for high humidity alarm" DEFVAL { 200 } ::= { analogObjects 32 } -- 1.3.6.1.4.1.9839.2.1.2.33 diff_pd OBJECT-TYPE SYNTAX Integer32 (0..360) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Return supply temp. difference for supply temp ala" DEFVAL { 30 } ::= { analogObjects 33 } -- 1.3.6.1.4.1.9839.2.1.2.34 min_fan_s_f5 OBJECT-TYPE SYNTAX Integer32 (0..32767) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "% reg. band for min speed or temp./pressure for min speed in condens." DEFVAL { 200 } ::= { analogObjects 34 } -- 1.3.6.1.4.1.9839.2.1.2.35 max_fan_s_f6 OBJECT-TYPE SYNTAX Integer32 (-32767..1580) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "% reg. band for max speed or temp./pressure for max speed in condens." DEFVAL { 1000 } ::= { analogObjects 35 } -- 1.3.6.1.4.1.9839.2.1.2.36 probeconvl OBJECT-TYPE SYNTAX Integer32 (0..32767) UNITS "%RH/bar x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Minimun value of humidity/pressure at 0mA, 4mA or 0Vdc" DEFVAL { 0 } ::= { analogObjects 36 } -- 1.3.6.1.4.1.9839.2.1.2.37 probeconvh OBJECT-TYPE SYNTAX Integer32 (-32767..1000) UNITS "%RH/bar x10" MAX-ACCESS read-write STATUS current DESCRIPTION "maximun value of humidity/pressure at 20mA or 1Vdc" DEFVAL { 1000 } ::= { analogObjects 37 } -- 1.3.6.1.4.1.9839.2.1.2.38 calibrazione_sonda_b1 OBJECT-TYPE SYNTAX Integer32 (-108..108) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Calibration probe B1" DEFVAL { 0 } ::= { analogObjects 38 } -- 1.3.6.1.4.1.9839.2.1.2.39 calibrazione_sonda_b2 OBJECT-TYPE SYNTAX Integer32 (-108..108) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Calibration probe B2" DEFVAL { 0 } ::= { analogObjects 39 } -- 1.3.6.1.4.1.9839.2.1.2.40 calibrazione_sonda_b3 OBJECT-TYPE SYNTAX Integer32 (-100..100) UNITS "%RH/bar x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Calibration probe B3" DEFVAL { 0 } ::= { analogObjects 40 } -- 1.3.6.1.4.1.9839.2.1.2.41 calibrazione_sonda_b4 OBJECT-TYPE SYNTAX Integer32 (-108..108) UNITS "°C x10" MAX-ACCESS read-write STATUS current DESCRIPTION "Calibration probe B4" DEFVAL { 0 } ::= { analogObjects 41 } -- 1.3.6.1.4.1.9839.2.1.3 integerObjects OBJECT IDENTIFIER ::= { uacMIB 3 } -- 1.3.6.1.4.1.9839.2.1.3.11 fan_h_count_fa OBJECT-TYPE SYNTAX Integer32 (0..30000) UNITS "hours" MAX-ACCESS read-write STATUS current DESCRIPTION "Supply fan hour counter" DEFVAL { 0 } ::= { integerObjects 11 } -- 1.3.6.1.4.1.9839.2.1.3.12 filt_h_count_fc OBJECT-TYPE SYNTAX Integer32 (0..30000) UNITS "hours" MAX-ACCESS read-write STATUS current DESCRIPTION "Filter hour counter" DEFVAL { 0 } ::= { integerObjects 12 } -- 1.3.6.1.4.1.9839.2.1.3.13 cmp1_h_count_c9 OBJECT-TYPE SYNTAX Integer32 (0..30000) UNITS "hours" MAX-ACCESS read-write STATUS current DESCRIPTION "compressor 1 hour counter" DEFVAL { 0 } ::= { integerObjects 13 } -- 1.3.6.1.4.1.9839.2.1.3.14 cmp2_h_count_ca OBJECT-TYPE SYNTAX Integer32 (0..30000) UNITS "hours" MAX-ACCESS read-write STATUS current DESCRIPTION "compressor 2 hour counter" DEFVAL { 0 } ::= { integerObjects 14 } -- 1.3.6.1.4.1.9839.2.1.3.15 en_fan_hc_f9 OBJECT-TYPE SYNTAX Integer32 (0..30000) UNITS "hours" MAX-ACCESS read-write STATUS current DESCRIPTION "Supply fan hour counter threshold" DEFVAL { 0 } ::= { integerObjects 15 } -- 1.3.6.1.4.1.9839.2.1.3.16 en_filt_hc_fb OBJECT-TYPE SYNTAX Integer32 (0..30000) UNITS "hours" MAX-ACCESS read-write STATUS current DESCRIPTION "Filter hour counter threshold" DEFVAL { 0 } ::= { integerObjects 16 } -- 1.3.6.1.4.1.9839.2.1.3.17 en_cmps_hc_c8 OBJECT-TYPE SYNTAX Integer32 (0..30000) UNITS "hours" MAX-ACCESS read-write STATUS current DESCRIPTION "compressor hour counter threshold" DEFVAL { 0 } ::= { integerObjects 17 } -- 1.3.6.1.4.1.9839.2.1.3.18 unit_model_h1 OBJECT-TYPE SYNTAX Integer32 (0..3) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Machine model" DEFVAL { 0 } ::= { integerObjects 18 } -- 1.3.6.1.4.1.9839.2.1.3.19 cool_mode_h5 OBJECT-TYPE SYNTAX Integer32 (1..5) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Operating mode of the 2 “cool” outputs" DEFVAL { 1 } ::= { integerObjects 19 } -- 1.3.6.1.4.1.9839.2.1.3.20 heat_mode_h6 OBJECT-TYPE SYNTAX Integer32 (0..4) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Operating mode of the 2 “heat” outputs" DEFVAL { 1 } ::= { integerObjects 20 } -- 1.3.6.1.4.1.9839.2.1.3.21 en_humidif_h8 OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Presence of humidifier" DEFVAL { 0 } ::= { integerObjects 21 } -- 1.3.6.1.4.1.9839.2.1.3.22 tempo_di_escursione_valvola_3 OBJECT-TYPE SYNTAX Integer32 (0..600) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "3P valve or damper excursion time" DEFVAL { 150 } ::= { integerObjects 22 } -- 1.3.6.1.4.1.9839.2.1.3.23 prop_pi_re OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Type of temperature regulation" DEFVAL { 0 } ::= { integerObjects 23 } -- 1.3.6.1.4.1.9839.2.1.3.24 pi_time_rf OBJECT-TYPE SYNTAX Integer32 (10..3600) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "Integration time for P+I action" DEFVAL { 600 } ::= { integerObjects 24 } -- 1.3.6.1.4.1.9839.2.1.3.25 conf_humid_h9 OBJECT-TYPE SYNTAX Integer32 (0..9) UNITS "flags" MAX-ACCESS read-write STATUS current DESCRIPTION "Type of dehumidification" DEFVAL { 0 } ::= { integerObjects 25 } -- 1.3.6.1.4.1.9839.2.1.3.26 conf_b2_hc OBJECT-TYPE SYNTAX Integer32 (0..3) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Function of probe B2" DEFVAL { 0 } ::= { integerObjects 26 } -- 1.3.6.1.4.1.9839.2.1.3.27 conf_b3_hd OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Function of probe B3" DEFVAL { 0 } ::= { integerObjects 27 } -- 1.3.6.1.4.1.9839.2.1.3.28 conf_anout2_hb OBJECT-TYPE SYNTAX Integer32 (0..2) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Function of output Y2" DEFVAL { 0 } ::= { integerObjects 28 } -- 1.3.6.1.4.1.9839.2.1.3.29 id_on_off_he OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF digital input" DEFVAL { 0 } ::= { integerObjects 29 } -- 1.3.6.1.4.1.9839.2.1.3.30 al_out_lgk_hf OBJECT-TYPE SYNTAX Integer32 (0..3) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Alarm relay logic" DEFVAL { 0 } ::= { integerObjects 30 } -- 1.3.6.1.4.1.9839.2.1.3.31 conf_deshum_ha OBJECT-TYPE SYNTAX Integer32 (0..7) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Function of the dehumidificat./humidif. Relay" DEFVAL { 0 } ::= { integerObjects 31 } -- 1.3.6.1.4.1.9839.2.1.3.32 conf_id_al_pb OBJECT-TYPE SYNTAX Integer32 (0..6) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Type of management of generic alarm input ID5" DEFVAL { 1 } ::= { integerObjects 32 } -- 1.3.6.1.4.1.9839.2.1.3.33 un_rot_num_h2 OBJECT-TYPE SYNTAX Integer32 (0..6) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "N. of machines in rotation" DEFVAL { 0 } ::= { integerObjects 33 } -- 1.3.6.1.4.1.9839.2.1.3.34 un_rot_adr_h3 OBJECT-TYPE SYNTAX Integer32 (1..6) UNITS "N/A" MAX-ACCESS read-write STATUS current DESCRIPTION "Address of unit in rotation" DEFVAL { 1 } ::= { integerObjects 34 } -- 1.3.6.1.4.1.9839.2.1.3.35 rot_time_h4 OBJECT-TYPE SYNTAX Integer32 (0..250) UNITS "hours" MAX-ACCESS read-write STATUS current DESCRIPTION "Rotation time between a series of units" DEFVAL { 0 } ::= { integerObjects 35 } -- 1.3.6.1.4.1.9839.2.1.3.36 presenza_sonda_1 OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Presence external air probe B2" DEFVAL { 0 } ::= { integerObjects 36 } -- 1.3.6.1.4.1.9839.2.1.3.37 tipo_sonda_2 OBJECT-TYPE SYNTAX Integer32 (0..2) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Type of humidity/press./temp. probe B3" DEFVAL { 0 } ::= { integerObjects 37 } -- 1.3.6.1.4.1.9839.2.1.3.38 presenza_sonda_3 OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Presence supply air B4" DEFVAL { 0 } ::= { integerObjects 38 } -- 1.3.6.1.4.1.9839.2.1.3.39 filtro_digitale OBJECT-TYPE SYNTAX Integer32 (1..15) UNITS "°C" MAX-ACCESS read-write STATUS current DESCRIPTION "Digital filter" DEFVAL { 4 } ::= { integerObjects 39 } -- 1.3.6.1.4.1.9839.2.1.3.40 limitazione_ingresso OBJECT-TYPE SYNTAX Integer32 (1..15) UNITS "N/A" MAX-ACCESS read-write STATUS current DESCRIPTION "Input limit" DEFVAL { 8 } ::= { integerObjects 40 } -- 1.3.6.1.4.1.9839.2.1.3.41 keyb_lockup_hi OBJECT-TYPE SYNTAX Integer32 (-32767..32767) UNITS "N/A" MAX-ACCESS read-write STATUS current DESCRIPTION "inibit parameter modifications" ::= { integerObjects 41 } -- 1.3.6.1.4.1.9839.2.1.3.42 param_set_hl OBJECT-TYPE SYNTAX Integer32 (0..3) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Parameter sets" DEFVAL { 0 } ::= { integerObjects 42 } -- 1.3.6.1.4.1.9839.2.1.3.43 display_cfg_hn OBJECT-TYPE SYNTAX Integer32 (0..2) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Select data shown on display" DEFVAL { 0 } ::= { integerObjects 43 } -- 1.3.6.1.4.1.9839.2.1.3.44 buzzer_cfg_p4 OBJECT-TYPE SYNTAX Integer32 (0..15) UNITS "min" MAX-ACCESS read-write STATUS current DESCRIPTION "P4 Buzzer activation" DEFVAL { 0 } ::= { integerObjects 44 } -- 1.3.6.1.4.1.9839.2.1.3.45 alm_reset_p5 OBJECT-TYPE SYNTAX Integer32 (1..5) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Reset alarms" DEFVAL { 1 } ::= { integerObjects 45 } -- 1.3.6.1.4.1.9839.2.1.3.48 user_pw_hh OBJECT-TYPE SYNTAX Integer32 (0..200) UNITS "N/A" MAX-ACCESS read-write STATUS current DESCRIPTION "USER password" DEFVAL { 22 } ::= { integerObjects 48 } -- 1.3.6.1.4.1.9839.2.1.3.49 sw_release_hr OBJECT-TYPE SYNTAX Integer32 (-32767..32767) UNITS "N/A" MAX-ACCESS read-only STATUS current DESCRIPTION "Software version" DEFVAL { 13 } ::= { integerObjects 49 } -- 1.3.6.1.4.1.9839.2.1.3.50 fan_config_f1 OBJECT-TYPE SYNTAX Integer32 (0..2) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Fan operating mode" DEFVAL { 1 } ::= { integerObjects 50 } -- 1.3.6.1.4.1.9839.2.1.3.51 min_volt_f2 OBJECT-TYPE SYNTAX Integer32 (0..32767) UNITS "step" MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum triac voltage threshold" DEFVAL { 35 } ::= { integerObjects 51 } -- 1.3.6.1.4.1.9839.2.1.3.52 max_volt_f3 OBJECT-TYPE SYNTAX Integer32 (-32767..100) UNITS "step" MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum triac voltage threshold" DEFVAL { 75 } ::= { integerObjects 52 } -- 1.3.6.1.4.1.9839.2.1.3.53 triac_durat_f4 OBJECT-TYPE SYNTAX Integer32 (0..15) UNITS "ms" MAX-ACCESS read-write STATUS current DESCRIPTION "Duration of triac impulse" DEFVAL { 2 } ::= { integerObjects 53 } -- 1.3.6.1.4.1.9839.2.1.3.54 min_out_val_f7 OBJECT-TYPE SYNTAX Integer32 (0..32767) UNITS "%" MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum output value" DEFVAL { 10 } ::= { integerObjects 54 } -- 1.3.6.1.4.1.9839.2.1.3.55 max_out_val_f8 OBJECT-TYPE SYNTAX Integer32 (-32767..100) UNITS "%" MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum output value" DEFVAL { 100 } ::= { integerObjects 55 } -- 1.3.6.1.4.1.9839.2.1.3.56 min_on_time_c1 OBJECT-TYPE SYNTAX Integer32 (0..300) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum ON time" DEFVAL { 60 } ::= { integerObjects 56 } -- 1.3.6.1.4.1.9839.2.1.3.57 min_off_time_c2 OBJECT-TYPE SYNTAX Integer32 (0..900) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum OFF time" DEFVAL { 60 } ::= { integerObjects 57 } -- 1.3.6.1.4.1.9839.2.1.3.58 t_betw_2_on_c3 OBJECT-TYPE SYNTAX Integer32 (0..900) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum time between two start-ups" DEFVAL { 360 } ::= { integerObjects 58 } -- 1.3.6.1.4.1.9839.2.1.3.59 t_comp_2_on_c4 OBJECT-TYPE SYNTAX Integer32 (0..300) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "ON delay between the 2 compressors" DEFVAL { 30 } ::= { integerObjects 59 } -- 1.3.6.1.4.1.9839.2.1.3.60 t_comp_2_off_c5 OBJECT-TYPE SYNTAX Integer32 (0..300) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "OFF delay between the 2 compressors" DEFVAL { 0 } ::= { integerObjects 60 } -- 1.3.6.1.4.1.9839.2.1.3.61 t_comp_fan_c7 OBJECT-TYPE SYNTAX Integer32 (0..300) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "Comp. ON delay from supply fan start-up" DEFVAL { 20 } ::= { integerObjects 61 } -- 1.3.6.1.4.1.9839.2.1.3.62 off_fan_d_fd OBJECT-TYPE SYNTAX Integer32 (0..900) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "Supply fan off delay" DEFVAL { 20 } ::= { integerObjects 62 } -- 1.3.6.1.4.1.9839.2.1.3.63 on_dalay_hg OBJECT-TYPE SYNTAX Integer32 (0..300) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "Delay on start-up" DEFVAL { 0 } ::= { integerObjects 63 } -- 1.3.6.1.4.1.9839.2.1.3.64 en_rotat_c6 OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Compressor rotation" DEFVAL { 0 } ::= { integerObjects 64 } -- 1.3.6.1.4.1.9839.2.1.3.65 d_flow_s_p1 OBJECT-TYPE SYNTAX Integer32 (0..250) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "Flow alarm delay from fan start-up" DEFVAL { 20 } ::= { integerObjects 65 } -- 1.3.6.1.4.1.9839.2.1.3.66 d_flow_run_p2 OBJECT-TYPE SYNTAX Integer32 (0..90) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "Flow alarm delay during operation" DEFVAL { 5 } ::= { integerObjects 66 } -- 1.3.6.1.4.1.9839.2.1.3.67 lp_delay_p3 OBJECT-TYPE SYNTAX Integer32 (0..250) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "Low pressure alarm delay from compress. Start-up" DEFVAL { 40 } ::= { integerObjects 67 } -- 1.3.6.1.4.1.9839.2.1.3.68 al_prb_delay_pa OBJECT-TYPE SYNTAX Integer32 (0..150) UNITS "min" MAX-ACCESS read-write STATUS current DESCRIPTION "Alarm delay high/low temperature/humidity on start-up" DEFVAL { 20 } ::= { integerObjects 68 } -- 1.3.6.1.4.1.9839.2.1.3.69 al_gen_delay_pc OBJECT-TYPE SYNTAX Integer32 (0..250) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "Generic alarm delay" DEFVAL { 60 } ::= { integerObjects 69 } -- 1.3.6.1.4.1.9839.2.1.3.70 t_slot_cfg_rt OBJECT-TYPE SYNTAX Integer32 (0..2) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Time band setting" DEFVAL { 0 } ::= { integerObjects 70 } -- 1.3.6.1.4.1.9839.2.1.3.71 fan_time_fe OBJECT-TYPE SYNTAX Integer32 (0..60) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "Fan pick-up time in condensation" DEFVAL { 4 } ::= { integerObjects 71 } -- 1.3.6.1.4.1.9839.2.1.3.72 abilitazione_allarme_fumo OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Input selection" DEFVAL { 0 } ::= { integerObjects 72 } -- 1.3.6.1.4.1.9839.2.1.3.73 abilitazione_allarme_cf OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "Water flow alarm enable" DEFVAL { 0 } ::= { integerObjects 73 } -- 1.3.6.1.4.1.9839.2.1.3.74 abilitazione_allarme_ht OBJECT-TYPE SYNTAX Integer32 (0..1) UNITS "flag" MAX-ACCESS read-write STATUS current DESCRIPTION "high temperature pre-alarm enable" DEFVAL { 0 } ::= { integerObjects 74 } END -- -- CAREL-uac.MIB --