FDRY-SNTP-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32 FROM SNMPv2-SMI -- [RFC2578] RowStatus FROM SNMPv2-TC -- [RFC2579] InetAddressType, InetAddress FROM INET-ADDRESS-MIB -- [RFC 4001] fdrySntp FROM FOUNDRY-SN-ROOT-MIB -- [snroo101] ; fdrySntpMIB MODULE-IDENTITY LAST-UPDATED "201708070000Z" -- 07 Aug 2017 ORGANIZATION "Ruckus Wireless, Inc.." CONTACT-INFO "Technical Support Center, Ruckus Wireless, Inc, 350 West Java Drive, Sunnyvale, CA 94089, USA Support URL: https://support.ruckuswireless.com Phone: +1-855-782-5871 ROW TF Numbers: https://support.ruckuswireless.com/contact-us" DESCRIPTION "The Ruckus Wireless proprietary MIB module for Simple Network Time Protocol(SNTP) It has new table combines Ipv4 and Ipv6 Simple Network Time Protocol server configuration. Copyright 1996-2017 Ruckus Wireless, Inc.. All rights reserved. This Ruckus Wireless, Inc SNMP Management Information Base Specification embodies Ruckus Wireless, Inc' confidential and proprietary intellectual property. Ruckus Wireless, Inc retains all title and ownership in the Specification, including any revisions. This Specification is supplied AS IS, and Ruckus Wireless, Inc makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification. " REVISION "201708070000Z" -- 07 Aug 2017 DESCRIPTION "Initial version, obsoletes the earlier snNTPServerTable." ::= { fdrySntp 1 } -- -- Top level components of this MIB. -- fdrySntpServer OBJECT IDENTIFIER ::= { fdrySntpMIB 1 } -- -- Ipv4/Ipv6 SNTP server table -- fdrySntpServerTable OBJECT-TYPE SYNTAX SEQUENCE OF FdrySntpServerTable MAX-ACCESS not-accessible STATUS current DESCRIPTION "Simple Network Time Protocol(SNTP) server table." ::= { fdrySntpServer 1 } fdrySntpServerEntry OBJECT-TYPE SYNTAX FdrySntpServerTable MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SNTP server table. This table uses running index as the Index to the table. Reasons to go for running index Scheme than IP addresses: 1. The table will be Virtual Routing and Forwarding(VRF) independent that multiple VRFs could share the same address type and address. 2. Index with address type and address could be potentially 17 unsigned integer, parsing and finding next index takes CPU time. The PDU gets to be huge too! 3. IP address is just another attribute, they are supposed to be list of servers." INDEX { fdrySntpServerIndex } ::= { fdrySntpServerTable 1 } FdrySntpServerTable ::= SEQUENCE { fdrySntpServerIndex Unsigned32, fdrySntpServerAddrType InetAddressType, fdrySntpServerAddr InetAddress, fdrySntpServerVersion Integer32, fdrySntpServerRowStatus RowStatus } fdrySntpServerIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index to the SNTP server Table. Maximum 3 Sntp servers are supported." ::= { fdrySntpServerEntry 1 } fdrySntpServerAddrType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-create STATUS current DESCRIPTION "SNTP server IP address Type. Supported address types are ipv4(1) and ipv6(2)" DEFVAL { ipv4 } ::= { fdrySntpServerEntry 2 } fdrySntpServerAddr OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-create STATUS current DESCRIPTION "SNTP server IP address." ::= { fdrySntpServerEntry 3 } fdrySntpServerVersion OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-create STATUS current DESCRIPTION "SNTP server version." DEFVAL { 3 } ::= { fdrySntpServerEntry 4 } fdrySntpServerRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This variable is used to create, modify, or delete a row in this table. When a row in this table is in active(1) state, no objects in that row can be modified except this object. " ::= { fdrySntpServerEntry 5 } END