BROCADE-STACK-ISSU-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32 FROM SNMPv2-SMI snSwitch FROM FOUNDRY-SN-SWITCH-GROUP-MIB DisplayString FROM FOUNDRY-SN-AGENT-MIB; brcdStackISSUMIB MODULE-IDENTITY LAST-UPDATED "201708070000Z" -- Aug 7, 2017 ORGANIZATION "Ruckus Wireless, Inc" CONTACT-INFO "Technical Support Center 350 West Java Drive, Sunnyvale, CA 94089, USA Support URL: https://support.ruckuswireless.com Phone: +1-855-782-5871 ROW TF Numbers: https://support.ruckuswireless.com/contact-us" DESCRIPTION " Management Information for Stack ISSU configuration and operational status. Supported Platforms: - supported on Ruckus Wireless ICX platforms. Copyright 1996-2017 Ruckus Wireless, Inc. All rights reserved. This Ruckus Wireless, Inc SNMP Management Information Base Specification embodies Ruckus Wireless, Inc confidential and proprietary intellectual property. Ruckus Wireless, Inc retains all title and ownership in the Specification, including any revisions. This Specification is supplied AS IS, and Ruckus Wireless, Inc Systems makes no warranty, either express or implied, as to the use, operation, condition, or performance of the specification, and any unintended consequence it may on the user environment." REVISION "201603150000Z" -- March 15, 2016 DESCRIPTION "Initial version" REVISION "201708070000Z" -- Aug 7, 2017 DESCRIPTION "Modified contact Info, Organization and Description" ::= { snSwitch 41} -- -- Stack ISSU feature -- brcdStackISSUGlobalObjects OBJECT IDENTIFIER ::= { brcdStackISSUMIB 1 } brcdStackISSUTableObjects OBJECT IDENTIFIER ::= { brcdStackISSUMIB 2 } -- -- Stack ISSU Global Scalar Object Section -- brcdStackISSUGlobalUpgradeOption OBJECT-TYPE SYNTAX INTEGER { none(0), primary(1), secondary(2), primaryOnErrorReloadPrimary (3), primaryOnErrorReloadSecondary (4), secondaryOnErrorReloadPrimary (5), secondaryOnErrorReloadSecondary (6), abort (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "User configures the system upgrade option to initiate stack upgrade process using primary or secondary image. The set operation is allowed only on the active unit in stacking system or 802.1BR (SPX) system. none: reserve state. primary: system upgrade process using primary image secondary: system upgrade process using secondary image primaryOnErrorReloadPrimary: system upgrade process using primary image, reload from primary if upgrade fails primaryOnErrorReloadSecondary: system upgrade process using primary image, reload from secondary if upgrade fails secondaryOnErrorReloadPrimary: system upgrade process using secondary image, reload from primary if upgrade fails secondaryOnErrorReloadSecondary: system upgrade process using secondary image, reload from secondary if upgrade fails abort: abort upgarde process. A reload is required to bring the stack back to working condition after abort is issued. The default is none state" ::= { brcdStackISSUGlobalObjects 1} brcdStackISSUGlobalUpgradeStatus OBJECT-TYPE SYNTAX INTEGER { notUpgrading (0), unitToBeUpgraded (1), unitJoin (2), unitVersionSync (3), unitReady (4), peUnitJoin (5), peUnitVersionSync (6), peUnitReady (7), standbyAssignment (8), standbySyncCompleted (9), stackSwitchover (10), stackSwitchoverCompleted (11), upgradeAbort(12), waitingForReload (13) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of upgrade process for a stacking or SPX system The default state is in notUpgrading state" ::= { brcdStackISSUGlobalObjects 2} brcdStackISSUGlobalUpgradeSystemReady OBJECT-TYPE SYNTAX INTEGER { notReadyUpgrade(0), ready(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The per-upgrade state of a stacking or SPX system. The system must be in ready state before the upgrade process starts. It checks the following aspects: Topology is Ring Yes Standby Present Yes Standby ready for upgrade Yes Flash use in progress No Secure Setup in progress No ISSU in progress No Election in progress No All units in ready state Yes Primary Image is upgrade compatible Yes Secondary Image is upgrade compatible Yes Startup config and Running Config Same Yes Config mode conflict No If one of above check fails, then system is not ready for stack upgrade" ::= { brcdStackISSUGlobalObjects 3} brcdStackISSUGlobalUpgradeError OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The error message of system upgrade process on a stacking or SPX system. The default is null string, which means system has no error or is in no-upgrade state " ::= { brcdStackISSUGlobalObjects 4} -- -- Stack ISSU Table Object Section -- -- -- Stack ISSU Status Unit Table -- Use this table to display upgrade status or other stacking (SPX) related information for each unit -- brcdStackISSUStatusUnitTable OBJECT-TYPE SYNTAX SEQUENCE OF BrcdStackISSUStatusUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Stack ISSU status unit table." ::= { brcdStackISSUTableObjects 1 } brcdStackISSUStatusUnitEntry OBJECT-TYPE SYNTAX BrcdStackISSUStatusUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the stack ISSU status table." INDEX { brcdStackISSUStatusUnitIndex } ::= { brcdStackISSUStatusUnitTable 1 } BrcdStackISSUStatusUnitEntry ::= SEQUENCE { brcdStackISSUStatusUnitIndex Integer32, brcdStackISSUStatusUnitSequence Integer32, brcdStackISSUStatusUnitType DisplayString, brcdStackISSUStatusUnitRole INTEGER, brcdStackISSUStatusUnitStatus INTEGER } brcdStackISSUStatusUnitIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The unit Id. If it is a SPX system, CB unit ID is from 1 to 16. PE unit ID is from 17 to 56" ::= { brcdStackISSUStatusUnitEntry 1 } brcdStackISSUStatusUnitSequence OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The sequence of upgrade in a stacking or SPX system. if unit is PE, the sequence number is the same as attached to the CB unit in a SPX system. The default is 0, which means system is in no-upgrade state" ::= { brcdStackISSUStatusUnitEntry 2 } brcdStackISSUStatusUnitType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A description of the system type for each unit." ::= { brcdStackISSUStatusUnitEntry 3 } brcdStackISSUStatusUnitRole OBJECT-TYPE SYNTAX INTEGER { other(1), active(2), standby(3), member(4), standalone(5), spxPe (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "A role for each unit " ::= { brcdStackISSUStatusUnitEntry 4 } brcdStackISSUStatusUnitStatus OBJECT-TYPE SYNTAX INTEGER { notUpgraded(0), upgrading (1), joined (2), versionSyncStart (3), versionSyncComplete (4), upgradeComplete (5), upgradeAbort(6), upgradePending (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of upgrade for each unit. The default is in notUpgraded state" ::= { brcdStackISSUStatusUnitEntry 5 } END