-- This file is corresponding to Release 9.1.10.101 from 2014/08/11 00:00:00 --------------------------------------------------------------------------- -- (C)opyright 2009-2014 bintec elmeg GmbH -- $RCSfile: mib-sysped,v $ -- $Revision: 1.7 $ -- $Date: 2014-02-07 10:37:50 $ --------------------------------------------------------------------------- FEC-SYSPED-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, mib-2, enterprises FROM SNMPv2-SMI DisplayString, TimeStamp, TruthValue FROM SNMPv2-TC sys, Date FROM BINTEC-MIB MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF; --------------------------------------------------------------------------- sysPEDMIB MODULE-IDENTITY LAST-UPDATED "201201240000Z" ORGANIZATION "bintec elmeg GmbH" CONTACT-INFO "EMail: info@bintec-elmeg.com Web: www.bintec-elmeg.com " DESCRIPTION "The MIB module for PED specific parts. " ::= { sys 6 } --------------------------------------------------------------------------- -- OID groups & all tables --------------------------------------------------------------------------- sysPedRelay OBJECT IDENTIFIER ::= { sysPEDMIB 1 } -- sysPedRelay1State 1 -- sysPedRelay2State 2 -- sysPedRelayCount 31 sysPedTemperature OBJECT IDENTIFIER ::= { sysPEDMIB 2 } -- sysPedTemperatureCurrent 1 -- sysPedTemperatureMax 2 -- sysPedTemperatureMaxTime 3 -- sysPedTemperatureMin 4 -- sysPedTemperatureMinTime 5 -- sysPedTemperatureUpdatePeriod 6 -- sysPedTemperatureLowerThreshold 7 -- sysPedTemperatureUpperThreshold 8 -- sysPedTemperatureAlarm 9 --------------------------------------------------------------------------- --------------------------------------------------------------------------- -- sysPedRelais --------------------------------------------------------------------------- sysPedRelay1State OBJECT-TYPE SYNTAX INTEGER { open(1), closed(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Relay control. open : Relay is open. closed: Relay is closed. Default state is open." DEFVAL { open } ::= { sysPedRelay 1 } sysPedRelay2State OBJECT-TYPE SYNTAX INTEGER { open(1), closed(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Relay control. open : Relay is open. closed: Relay is closed. Default state is open." DEFVAL { open } ::= { sysPedRelay 2 } sysPedRelayCount OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Number of available relays in the system." ::= { sysPedRelay 31 } --------------------------------------------------------------------------- --------------------------------------------------------------------------- -- sysPedTemperature --------------------------------------------------------------------------- sysPedTemperatureCurrent OBJECT-TYPE SYNTAX INTEGER (-55..150) UNITS "degree Centigrade" MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature during the last measurement time." ::= { sysPedTemperature 1 } sysPedTemperatureMax OBJECT-TYPE SYNTAX INTEGER (-55..150) UNITS "degree Centigrade" MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum observed temperature." ::= { sysPedTemperature 2 } sysPedTemperatureMaxTime OBJECT-TYPE SYNTAX Date MAX-ACCESS read-only STATUS current DESCRIPTION "Point in time the maximum temperature was observed." ::= { sysPedTemperature 3 } sysPedTemperatureMin OBJECT-TYPE SYNTAX INTEGER (-55..150) UNITS "degree Centigrade" MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum observed temperature." ::= { sysPedTemperature 4 } sysPedTemperatureMinTime OBJECT-TYPE SYNTAX Date MAX-ACCESS read-only STATUS current DESCRIPTION "Point in time the minimum temperature was observed." ::= { sysPedTemperature 5 } sysPedTemperatureUpdatePeriod OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Measurement interval of temperature update in seconds. 0: Disable measurements." DEFVAL { 10 } ::= { sysPedTemperature 6 } sysPedTemperatureLowerThreshold OBJECT-TYPE SYNTAX INTEGER (-55..125) UNITS "degree Centigrade" MAX-ACCESS read-write STATUS current DESCRIPTION "Minimal allowed temperature. If temperature falls below this threshold, a syslog message is generated." DEFVAL { -25 } ::= { sysPedTemperature 7 } sysPedTemperatureUpperThreshold OBJECT-TYPE SYNTAX INTEGER (-55..125) UNITS "degree Centigrade" MAX-ACCESS read-write STATUS current DESCRIPTION "Maximal allowed temperature. If temperature raises above this threshold, a syslog message is generated." DEFVAL { 70 } ::= { sysPedTemperature 8 } sysPedTemperatureAlarm OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if the defined temperature thresholds are violated." DEFVAL { false } ::= { sysPedTemperature 9 } --------------------------------------------------------------------------- END