-- ***************************************************************************** -- Bachmann GmbH, Stuttgart -- BACHMANN-BLUENET2-MIB Version 1.0 -- -- Management Information Base for SNMP Network Management -- -- Copyright 2013 Bachmann GmbH. -- All Rights Reserved. -- -- ***************************************************************************** -- File : $RCSfile: BACHMANN-BLUENET2-MIB.txt,v $ -- Rev. : $Revision: 1.17 $ -- Date : $Date: 2015/09/22 16:45:34 $ -- Author : $Author: fis $ -- Id : $Id: BACHMANN-BLUENET2-MIB.txt,v 1.17 2015/09/22 16:45:34 fis Exp $ -- ***************************************************************************** BACHMANN-BLUENET2-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, Integer32, Unsigned32, TimeTicks FROM SNMPv2-SMI MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP FROM SNMPv2-CONF DateAndTime, DisplayString, RowStatus, TEXTUAL-CONVENTION FROM SNMPv2-TC sysObjectID FROM SNMPv2-MIB bachmann FROM BACHMANN-SMI-MIB; blueNet2Mib MODULE-IDENTITY LAST-UPDATED "201507010000Z" ORGANIZATION "Bachmann GmbH" CONTACT-INFO "www.bachmann.com Bachmann GmbH Ernsthaldenstrasse 33 D-70565 Stuttgart Germany, Europe Tel. +49 711 86602-0 Fax +49 711 86602-34 info@bachmann.com" DESCRIPTION "The MIB module for representing BlueNet2 PDU SNMP agent implementation version v1.01.00." REVISION "201507010000Z" DESCRIPTION "The MIB module for representing BlueNet2 PDU SNMP agent implementation version v1.00.00." REVISION "201506010000Z" DESCRIPTION "Version 10100 of BlueNet2 PDU MIB." REVISION "201502010000Z" DESCRIPTION "Initial Version of BlueNet2 PDU MIB." -- ::= { iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) bachmann(31770) blueNet2Mib(2) } ::= { bachmann 2 } -- ***************************************************************************** -- bachmann OBJECT IDENTIFIER ::= { enterprises 31770 } -- blueNet2Mib OBJECT IDENTIFIER ::= { bachmann 2 } blueNet2Notifications OBJECT IDENTIFIER ::= { blueNet2Mib 0 } blueNet2Products OBJECT IDENTIFIER ::= { blueNet2Mib 1 } blueNet2Objects OBJECT IDENTIFIER ::= { blueNet2Mib 2 } blueNet2Identification OBJECT IDENTIFIER ::= { blueNet2Objects 1 } blueNet2Information OBJECT IDENTIFIER ::= { blueNet2Objects 2 } blueNet2Configuration OBJECT IDENTIFIER ::= { blueNet2Objects 3 } blueNet2Devices OBJECT IDENTIFIER ::= { blueNet2Objects 4 } blueNet2Sensors OBJECT IDENTIFIER ::= { blueNet2Objects 5 } blueNet2Circuits OBJECT IDENTIFIER ::= { blueNet2Objects 6 } blueNet2SocketGroups OBJECT IDENTIFIER ::= { blueNet2Objects 7 } blueNet2Variables OBJECT IDENTIFIER ::= { blueNet2Objects 8 } blueNet2MPStates OBJECT IDENTIFIER ::= { blueNet2Objects 9 } blueNet2Traps OBJECT IDENTIFIER ::= { blueNet2Mib 3 } blueNet2Conformance OBJECT IDENTIFIER ::= { blueNet2Mib 4 } -- blueNet2Capabilities OBJECT IDENTIFIER ::= { blueNet2Mib 5 } -- ***************************************************************************** BlueNet2ComponentStates ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the possible values of component states." SYNTAX INTEGER { ok (1), warning (2), alarm (3) } BlueNet2EntitySources ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the possible source of entity variables." SYNTAX INTEGER { other (1), device (2), sensor (3), circuit (4), phase (5), fuse (6), socket (7), socketgroup (8), rcm (9) } BlueNet2EntityStates ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the possible values of entity states." SYNTAX INTEGER { expected (0), undefined (1), ok (2), errorHigh (3), errorLow (4), warningHigh (5), warningLow (6), lost (7), deactivate (8), onAlarmIdentidy (9), offAlarmIdentify(10), onAlarm (11), offAlarm (12), onWarningIdentify (13), offWarningIdentify (14), onWarning (15), offWarning (16), onIdentify (17), offIdentify (18), on (19), off (20), onChildAlarm (21), offChildAlarm (22), onChildWarning (23), offChildWarning (24), childAlarm (25), childWarning (26), lostChild (27), updateInProgress (36), updateError (37), onGoingSwitch (38), high (39), low (40), alarm (41), warning (42), ok (43), disabled (44), fwVersionTooNew (45) } BlueNet2EntityBits ::= TEXTUAL-CONVENTION DISPLAY-HINT "1x:" STATUS current DESCRIPTION "Each octet within this value specifies a set of eight BlueNet2EntityStates, with the first octet specifying 0 through 7, the second octet specifying states 8 through 15, etc. Within each octet, the most significant bit represents the lowest numbered state, and the least significant bit represents the highest numbered state. Thus, each state is represented by a single bit within the value of this object. If that bit has a value of '1' then that state is included in the set of states; the states is not included if its bit has a value of '0'." SYNTAX OCTET STRING (SIZE (8..8)) BlueNet2DataSourceTypes ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the possible values of data sources. (1) voltage (2) peak voltage, can be reset by user (4) current (5) peak current, can be reset by user (7) differential current AC (8) differential current DC (9) neutral current if more than one phase is present (16) phase angle (17) power factor (18) apparent power (19) active power (20) peak active power (21) peak active power, can be reset by user (22) reactive power (23) frequency (24) peak neutral current (32) apparent energy accumulated (33) apparent energy delta (34) reactive energy accumulated (35) reactive energy delta (36) active energy accumulated (37) active energy delta (38) active energy accumulated, can be reset by the user (39) active energy runtime (40) custom energy runtime, can be reset by the user (48) fuse state (on, off etc) (49) orientation as calculated by the gyro sensor (50) usb (51) socket state (52) pdu state (53) state of an external i2c sensor (54) circuit state (55) phase state (56) rcd state (57) socketGroup state (58) global state (64) (external) sensor type (65) circuit type (66) fuse type (67) socket type (68) socket color (69) phase type (70) pdu type (71) rcm type (80) delta voltage 12 (81) delta voltage 23 (82) delta voltage 31 (83) rcm AC peak value (84) rcm DC peak value (256) temperature (257) humidity (258) general purpose i/o input channel 1 (259) general purpose i/o input channel 2 (260) general purpose i/o input channel 3 (261) general purpose i/o input channel 4 (262) general purpose i/o output channel 1 (263) general purpose i/o output channel 2 (264) general purpose i/o output channel 3 (265) general purpose i/o output channel 4 (266) dew point (267) pressure (268) differential pressure (269) co2 equivalent (air quality) (270) total volatile organic components (air quality) (65535) Unspecified" SYNTAX INTEGER { voltage (1), peakVoltage (2), current (4), peakCurrent (5), differentialCurrentAc(7), differentialCurrentDc(8), neutralCurrent (9), phaseAngle (16), powerFactor (17), apparentPower (18), activePower (19), peakActivePower (20), peakActivePowerUser(21), reactivePower (22), frequency (23), peakNeutralCurrent(24), apparentEnergyAccumulated(32), apparentEnergyDelta(33), reactiveEnergyAccumulated(34), reactiveEnergyDelta(35), activeEnergyAccumulated(36), activeEnergyDelta(37), activeEnergyAccumulatedUser(38), activeEnergyRuntime(39), customEnergyRuntimeUser(40), fuseState (48), orientation (49), usb (50), socketState (51), pduState (52), sensorState (53), circuitState (54), phaseState (55), rcdState (56), socketGroupState (57), globalState (58), sensorType (64), circuitType (65), fuseType (66), socketType (67), socketColor (68), phaseType (69), pduType (70), rcmType (71), deltaVoltage12 (80), deltaVoltage23 (81), deltaVoltage31 (82), rcmACPeak (83), rcmDCPeak (84), temperature (256), humidity (257), ioInputChannel1 (258), ioInputChannel2 (259), ioInputChannel3 (260), ioInputChannel4 (261), ioOutputChannel1(262), ioOutputChannel2(263), ioOutputChannel3(264), ioOutputChannel4(265), dewPoint (266), pressure (267), diffPressure (268), co2Equivalent (269), tvoc (270), unspecified (65535) } BlueNet2DataSourceUnits ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the possible units of data sources. Definitions according to CiA 2006." SYNTAX INTEGER { metre (1), kilogram (2), second (3), ampere (4), kelvin (5), mole (6), candela (7), radian (16), steradian (17), hertz (32), newton (33), pascal (34), joule (35), watt (36), coulomb (37), volt (38), farad (39), ohm (40), siemens (41), weber (42), tesla (43), henry (44), celsius (45), lumen (46), lux (47), becquerel (48), gray (49), sievert (50), katal (51), grade (64), degree (65), aMinuteAngle (66), aSecondAngle (67), litre (68), are (69), hectare (70), minute (71), hour (72), day (73), year (74), gram (75), tonne (76), bar (78), poise (79), stokes (80), electronvolt (81), atomicMass (82), astronomic (83), parsec (84), metrePerS2 (85), newtonMetre (86), s2 (87), m2 (88), m3 (89), pascalSecond (90), jPerKgK (91), wPerMK (92), jPerMoleK (93), wPerM2Sr (94), katPerM3 (95), kiloWattHour (240), percentage (241), va (242), var (243), kiloVaHour (244), kiloVarHour (245), milliAmpere (246), unit (255) } BlueNet2InfoMessageSources ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the source of a message." SYNTAX INTEGER { other (1), device (2), sensor (3), variable (4) } BlueNet2SocketModes ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the mode of a socket or socket group or its LEDs. A socket or socket group can be notSwitchable or switchedOn/Off. A socket group may also have different sockets switchedOnAndOff. A socket or socket group can be set using switchedOn/Off only. A socket group without any socket at all has mode notAvailable." SYNTAX INTEGER { switchedOn (1), switchedOff (2), switchedOnAndOff(3), notAvailable (4), notSwitchable (5) } BlueNet2SocketMembers ::= TEXTUAL-CONVENTION DISPLAY-HINT "1x:" STATUS current DESCRIPTION "Each octet within this value specifies a set of eight sockets, with the first octet specifying sockets 1 through 8, the second octet specifying sockets 9 through 16, etc. Within each octet, the most significant bit represents the lowest numbered socket, and the least significant bit represents the highest numbered socket. Thus, each socket of the pdu is represented by a single bit within the value of this object. If that bit has a value of '1' then that socket is included in the set of sockets; the socket is not included if its bit has a value of '0'." SYNTAX OCTET STRING (SIZE (1..255)) BlueNet2GPIOModes ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the mode of GPIO input or output." SYNTAX INTEGER { disabled (0), enabled (2), s0 (6), undefined (7) } BlueNet2GPIOSwitch ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the state to switch on/off GPIO output." SYNTAX INTEGER { undefined (0), switchable (3), notSwitchable (5), on (1), off (2) } BlueNet2RcmSelftestCommand ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents RCM self-test commands with or without alarm or selftest notifications." SYNTAX INTEGER { selftestWithoutAnyNotification (0), selftestWithAlarmNotifyOnly (1), selftestWithSelftestNotifyOnly (2), selftestWithAlarmAndSelftestNotify (3), selftestCommand (4) } BlueNet2RcmSelftestResult ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents RCM self-test result values." SYNTAX INTEGER { notRun (0), notReachable (1), success (2), failure (3), partialSuccess (4), cancelled (5), notApplicable (255) } -- ***************************************************************************** -- Notifications -- blueNet2NotificationPrefix OBJECT IDENTIFIER ::= { blueNet2Notifications 0 } blueNet2PduStatusOkNotification NOTIFICATION-TYPE OBJECTS { blueNet2DeviceGuid, blueNet2DeviceStatus, blueNet2DeviceAlarm } STATUS current DESCRIPTION "PDU status ok." -- -- #CATEGORY "Status Events." -- #TYPE "PDU status ok." -- #SUMMARY "Guid %x device status is %i: %s." -- #ARGUMENTS {0,1,2} -- #SEVERITY INFORMATIONAL -- #STATE OPERATIONAL -- ::= { blueNet2NotificationPrefix 1 } blueNet2PduStatusWarningNotification NOTIFICATION-TYPE OBJECTS { blueNet2DeviceGuid, blueNet2DeviceStatus, blueNet2DeviceAlarm } STATUS current DESCRIPTION "PDU status warning." -- -- #CATEGORY "Status Events." -- #TYPE "PDU status warning." -- #SUMMARY "Guid %x device status is %i: %s." -- #ARGUMENTS {0,1,2} -- #SEVERITY MINOR -- #STATE OPERATIONAL -- ::= { blueNet2NotificationPrefix 2 } blueNet2PduStatusAlarmNotification NOTIFICATION-TYPE OBJECTS { blueNet2DeviceGuid, blueNet2DeviceStatus, blueNet2DeviceAlarm } STATUS current DESCRIPTION "PDU status alarm." -- -- #CATEGORY "Status Events." -- #TYPE "PDU status alarm." -- #SUMMARY "Guid %x device status is %i: %s." -- #ARGUMENTS {0,1,2} -- #SEVERITY MAJOR -- #STATE OPERATIONAL -- ::= { blueNet2NotificationPrefix 3 } blueNet2SensorStatusOkNotification NOTIFICATION-TYPE OBJECTS { blueNet2SensorGuid, blueNet2SensorStatus, blueNet2SensorAlarm } STATUS current DESCRIPTION "Sensor status ok." -- -- #CATEGORY "Status Events." -- #TYPE "Sensor status ok." -- #SUMMARY "Guid %x sensor status is %i: %s." -- #ARGUMENTS {0,1,2} -- #SEVERITY INFORMATIONAL -- #STATE OPERATIONAL -- ::= { blueNet2NotificationPrefix 4 } blueNet2SensorStatusWarningNotification NOTIFICATION-TYPE OBJECTS { blueNet2SensorGuid, blueNet2SensorStatus, blueNet2SensorAlarm } STATUS current DESCRIPTION "Sensor status warning." -- -- #CATEGORY "Status Events." -- #TYPE "Sensor status warning." -- #SUMMARY "Guid %x sensor status is %i: %s." -- #ARGUMENTS {0,1,2} -- #SEVERITY MINOR -- #STATE OPERATIONAL -- ::= { blueNet2NotificationPrefix 5 } blueNet2SensorStatusAlarmNotification NOTIFICATION-TYPE OBJECTS { blueNet2SensorGuid, blueNet2SensorStatus, blueNet2SensorAlarm } STATUS current DESCRIPTION "Sensor status alarm." -- -- #CATEGORY "Status Events." -- #TYPE "Sensor status alarm." -- #SUMMARY "Guid %x sensor status is %i: %s." -- #ARGUMENTS {0,1,2} -- #SEVERITY INFORMATIONAL -- #STATE OPERATIONAL -- ::= { blueNet2NotificationPrefix 6 } blueNet2VariableStatusOkNotification NOTIFICATION-TYPE OBJECTS { blueNet2VariableDataGuid, blueNet2VariableDataStatus, blueNet2VariableDataValue, blueNet2VariableAlarm } STATUS current DESCRIPTION "Variable status ok." -- -- #CATEGORY "Threshold Events." -- #TYPE "Variable status ok." -- #SUMMARY "Guid %x variable value %i is ok (%i), %s." -- #ARGUMENTS {0,1,2,3} -- #SEVERITY INFORMATIONAL -- #STATE OPERATIONAL -- ::= { blueNet2NotificationPrefix 7 } blueNet2VariableLowerWarningNotification NOTIFICATION-TYPE OBJECTS { blueNet2VariableDataGuid, blueNet2VariableDataStatus, blueNet2VariableDataValue, blueNet2VariableSetPointLowerAlarm, blueNet2VariableAlarm } STATUS current DESCRIPTION "Variable status lower warning." -- -- #CATEGORY "Threshold Events." -- #TYPE "Variable status lower warning." -- #SUMMARY "Guid %x variable value %i deceeds %i (%i), %s." -- #ARGUMENTS {0,2,1,3,4} -- #SEVERITY MINOR -- #STATE OPERATIONAL -- ::= { blueNet2NotificationPrefix 8 } blueNet2VariableUpperWarningNotification NOTIFICATION-TYPE OBJECTS { blueNet2VariableDataGuid, blueNet2VariableDataStatus, blueNet2VariableDataValue, blueNet2VariableSetPointUpperWarning, blueNet2VariableAlarm } STATUS current DESCRIPTION "Variable status upper warning." -- -- #CATEGORY "Threshold Events." -- #TYPE "Variable status upper warning." -- #SUMMARY "Guid %x variable value %i exceeds %i (%i), %s." -- #ARGUMENTS {0,2,1,3,4} -- #SEVERITY MINOR -- #STATE OPERATIONAL -- ::= { blueNet2NotificationPrefix 9 } blueNet2VariableLowerAlarmNotification NOTIFICATION-TYPE OBJECTS { blueNet2VariableDataGuid, blueNet2VariableDataStatus, blueNet2VariableDataValue, blueNet2VariableSetPointLowerAlarm, blueNet2VariableAlarm } STATUS current DESCRIPTION "Variable status lower alarm." -- -- #CATEGORY "Threshold Events." -- #TYPE "Variable status lower alarm." -- #SUMMARY "Guid %x variable value %i deceeds %i (%i), %s." -- #ARGUMENTS {0,2,1,3,4} -- #SEVERITY MAJOR -- #STATE OPERATIONAL -- ::= { blueNet2NotificationPrefix 10 } blueNet2VariableUpperAlarmNotification NOTIFICATION-TYPE OBJECTS { blueNet2VariableDataGuid, blueNet2VariableDataStatus, blueNet2VariableDataValue, blueNet2VariableSetPointUpperAlarm, blueNet2VariableAlarm } STATUS current DESCRIPTION "Variable status upper alarm." -- -- #CATEGORY "Threshold Events." -- #TYPE "Variable status upper alarm." -- #SUMMARY "Guid %x variable value %i exceeds %i (%i), %s." -- #ARGUMENTS {0,2,1,3,4} -- #SEVERITY MAJOR -- #STATE OPERATIONAL -- ::= { blueNet2NotificationPrefix 11 } blueNet2ReconfigAgentNotification NOTIFICATION-TYPE OBJECTS { sysObjectID } STATUS current DESCRIPTION "Agent reconfiguration." -- -- #CATEGORY "Status Events." -- #TYPE "Agent status." -- #SUMMARY "Agent type: %s, Status: configuration has changed." -- #ARGUMENTS {0} -- #SEVERITY INFORMATIONAL -- #TIMEINDEX 6 -- #STATE OPERATIONAL -- ::= { blueNet2NotificationPrefix 98 } blueNet2ShutdownAgentNotification NOTIFICATION-TYPE OBJECTS { sysObjectID } STATUS current DESCRIPTION "Agent shutdown." -- -- #CATEGORY "Status Events." -- #TYPE "Agent status." -- #SUMMARY "Agent type: %s, Status: shutdown." -- #ARGUMENTS {0} -- #SEVERITY SEVERE -- #TIMEINDEX 6 -- #STATE NONOPERATIONAL -- ::= { blueNet2NotificationPrefix 99 } -- ***************************************************************************** -- Products -- -- please refer to BACHMANN-BLUENET2-PRODUCTS-MIB definitions -- ***************************************************************************** -- Objects -- -- ============================================================================= -- blueNet2Identification: global BlueNet2 PDU product identification -- blueNet2IdProductVendor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "BlueNet2 vendor name." ::= { blueNet2Identification 1 } blueNet2IdProductName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "BlueNet2 product name." ::= { blueNet2Identification 2 } blueNet2IdProductURI OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "URI of BlueNet2 PDU product." ::= { blueNet2Identification 3 } blueNet2IdProductPartNr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Part number of BlueNet2 PDU product." ::= { blueNet2Identification 4 } blueNet2IdProductSNr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique serial number of BlueNet2 PDU product." ::= { blueNet2Identification 5 } blueNet2IdProductDate OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Production date of BlueNet2 PDU product." ::= { blueNet2Identification 6 } blueNet2IdProductFacility OBJECT-TYPE SYNTAX INTEGER { neutralCurrent (0), fuse (1), rcd (2), identify (3), switch (4), oneInlet (5), monitoredPerOutlet(6), monitoredPerPhase(7), spd (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Functional product facility of BlueNet2 PDU product. 0 : number of phases is 3 1 : has real fuses 2 : has any RCMs 3 : has sockets 4 : sockets can be switched 5 : has one inlet 6 : measurement is done on socket layer 7 : measurement is done on phase layer 8 : has any SPDs" ::= { blueNet2Identification 7 } blueNet2IdProductCaps OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Capabilities of BlueNet2 PDU product as referred in BACHMANN-BLUENET2-CAPABILITY-MIB blueNet2Capabilities. e.g. read 10203 as 01 02 03 to get version 1.2.3." ::= { blueNet2Identification 8 } blueNet2IdProductFwV OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware revision of BlueNet2 PDU." ::= { blueNet2Identification 9 } blueNet2IdProductHwV OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware revision of BlueNet2 PDU." ::= { blueNet2Identification 10 } blueNet2IdProductSwV OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Software revision of BlueNet2 PDU." ::= { blueNet2Identification 11 } blueNet2IdProductOsV OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Operating system revision of BlueNet2 PDU." ::= { blueNet2Identification 12 } blueNet2IdProductArch OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Operating system cpu architecture of BlueNet2 PDU." ::= { blueNet2Identification 13 } blueNet2IdProductMAC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet MAC address of BlueNet2 PDU." ::= { blueNet2Identification 14 } -- ============================================================================= -- blueNet2Information: global BlueNet2 PDU information -- blueNet2InfoUpTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Uptime of the BlueNet2 PDU operating system in seconds. This is different to the sysUpTime since agent (re-)start." ::= { blueNet2Information 1 } blueNet2InfoOverallStatus OBJECT-TYPE SYNTAX BlueNet2ComponentStates MAX-ACCESS read-only STATUS current DESCRIPTION "General hadware status of BlueNet2 PDU." ::= { blueNet2Information 2 } blueNet2InfoNumberOfChanges OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of global configuration changes." ::= { blueNet2Information 3 } blueNet2InfoLastChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the sysUpTime object at which the last change in global configuration happened." ::= { blueNet2Information 4 } blueNet2InfoAccumulatedStatus OBJECT-TYPE SYNTAX BlueNet2EntityBits MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field of all current states." ::= { blueNet2Information 5 } blueNet2InfoLoadTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2InfoLoadEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of system load entries." ::= { blueNet2Information 6 } blueNet2InfoLoadEntry OBJECT-TYPE SYNTAX BlueNet2InfoLoadEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of system load table." INDEX { blueNet2InfoLoadIndex } ::= { blueNet2InfoLoadTable 1 } BlueNet2InfoLoadEntry ::= SEQUENCE { blueNet2InfoLoadIndex Unsigned32, blueNet2InfoLoadAverage Unsigned32 } blueNet2InfoLoadIndex OBJECT-TYPE SYNTAX Unsigned32 (1..10) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for the system load table. These are the past minutes the load is given for." ::= { blueNet2InfoLoadEntry 1 } blueNet2InfoLoadAverage OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "System load average multiplied by 100." ::= { blueNet2InfoLoadEntry 2 } blueNet2InfoMessageTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2InfoMessageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of the last text message per source." ::= { blueNet2Information 7 } blueNet2InfoMessageEntry OBJECT-TYPE SYNTAX BlueNet2InfoMessageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of last message table." INDEX { blueNet2InfoMessageSource } ::= { blueNet2InfoMessageTable 1 } BlueNet2InfoMessageEntry ::= SEQUENCE { blueNet2InfoMessageSource BlueNet2InfoMessageSources, blueNet2InfoMessageStatus BlueNet2ComponentStates, blueNet2InfoMessageTime TimeTicks, blueNet2InfoMessageText DisplayString, blueNet2InfoMessageNumberOfOks Unsigned32, blueNet2InfoMessageNumberOfWarnings Unsigned32, blueNet2InfoMessageNumberOfErrors Unsigned32 } blueNet2InfoMessageSource OBJECT-TYPE SYNTAX BlueNet2InfoMessageSources MAX-ACCESS not-accessible STATUS current DESCRIPTION "Source of the text message." ::= { blueNet2InfoMessageEntry 1 } blueNet2InfoMessageStatus OBJECT-TYPE SYNTAX BlueNet2ComponentStates MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the text message source." ::= { blueNet2InfoMessageEntry 2 } blueNet2InfoMessageTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last received text message according to operating time sysUpTime." ::= { blueNet2InfoMessageEntry 3 } blueNet2InfoMessageText OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Last text message of a source." ::= { blueNet2InfoMessageEntry 4 } blueNet2InfoMessageNumberOfOks OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated number of ok messages." ::= { blueNet2InfoMessageEntry 5 } blueNet2InfoMessageNumberOfWarnings OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated number of warning messages." ::= { blueNet2InfoMessageEntry 6 } blueNet2InfoMessageNumberOfErrors OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated number of error messages." ::= { blueNet2InfoMessageEntry 7 } -- ============================================================================= -- blueNet2Configuration: global BlueNet2 PDU configuration -- blueNet2Alias OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "BlueNet2 product alias. This object should be set by the administrator." ::= { blueNet2Configuration 1 } blueNet2Language OBJECT-TYPE SYNTAX INTEGER { other (1), english (2), german (3), french (4) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Supported display language." DEFVAL { english } ::= { blueNet2Configuration 2 } blueNet2DateTime OBJECT-TYPE SYNTAX DateAndTime -- DISPLAY-HINT "2d-1d-1d,1d:1d:1d.1d,1a1d:1d" MAX-ACCESS read-write STATUS current DESCRIPTION "Date and time of day as set manually or by NTP." ::= { blueNet2Configuration 3 } blueNet2Protocols OBJECT IDENTIFIER ::= { blueNet2Configuration 4 } blueNet2FtpAccess OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Ftp access status." DEFVAL { disabled } ::= { blueNet2Protocols 1 } blueNet2FtpPort OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "TCP/IP port of FTP daemon." DEFVAL { 21 } ::= { blueNet2Protocols 2 } blueNet2HttpAccess OBJECT-TYPE SYNTAX BITS { httpEnabled (0), httpsEnabled (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "HTTP/HTTPS access status." DEFVAL { { httpsEnabled } } ::= { blueNet2Protocols 3 } blueNet2HttpPort OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "TCP/IP port of HTTP daemon." DEFVAL { 80 } ::= { blueNet2Protocols 4 } blueNet2HttpsPort OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "TCP/IP port of HTTPS daemon." DEFVAL { 443 } ::= { blueNet2Protocols 5 } blueNet2SftpAccess OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Sftp access status." DEFVAL { disabled } ::= { blueNet2Protocols 6 } blueNet2SftpPort OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "TCP/IP port of SFTP daemon." DEFVAL { 115 } ::= { blueNet2Protocols 7 } blueNet2SshAccess OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Ssh access status." DEFVAL { enabled } ::= { blueNet2Protocols 8 } blueNet2SshPort OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "TCP/IP port of SSH daemon." DEFVAL { 22 } ::= { blueNet2Protocols 9 } blueNet2TelnetAccess OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Telnet access status." DEFVAL { disabled } ::= { blueNet2Protocols 10 } blueNet2TelnetPort OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "TCP/IP port of telnet daemon." DEFVAL { 23 } ::= { blueNet2Protocols 11 } -- ----------------------------------------------------------------------------- blueNet2Snmp OBJECT IDENTIFIER ::= { blueNet2Protocols 12 } blueNet2SnmpVersions OBJECT-TYPE SYNTAX BITS { snmpv1 (0), snmpv2c (1), snmpv3 (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Supported and enabled SNMP versions." DEFVAL { { snmpv1, snmpv2c, snmpv3 } } ::= { blueNet2Snmp 1 } blueNet2MaxTrapReceivers OBJECT-TYPE SYNTAX Unsigned32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of entries in blueNet2TrapReceiverTable." ::= { blueNet2Snmp 2 } blueNet2TrapReceiverTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2TrapReceiverEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of trap receiver entries." ::= { blueNet2Snmp 3 } blueNet2TrapReceiverEntry OBJECT-TYPE SYNTAX BlueNet2TrapReceiverEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of trapTable." INDEX { blueNet2TrapReceiverIndex } ::= { blueNet2TrapReceiverTable 1 } BlueNet2TrapReceiverEntry ::= SEQUENCE { blueNet2TrapReceiverIndex Unsigned32, blueNet2TrapReceiverRowStatus RowStatus, blueNet2TrapReceiverProtocol INTEGER, blueNet2TrapReceiverAddress DisplayString, blueNet2TrapReceiverFriendlyName DisplayString, blueNet2TrapReceiverDescription DisplayString, blueNet2TrapReceiverCommunity DisplayString, blueNet2TrapReceiverUsername DisplayString } blueNet2TrapReceiverIndex OBJECT-TYPE SYNTAX Unsigned32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the trap receiver table." ::= { blueNet2TrapReceiverEntry 1 } blueNet2TrapReceiverRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Activate/create/destroy/disable a trap receiver entry." ::= { blueNet2TrapReceiverEntry 2 } blueNet2TrapReceiverProtocol OBJECT-TYPE SYNTAX INTEGER { snmpv1Trap (1), snmpv2cTrap (2), snmpv2cInform (3), snmpv3Trap (4), snmpv3Inform (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Set trap/inform version." DEFVAL { snmpv1Trap } ::= { blueNet2TrapReceiverEntry 3 } blueNet2TrapReceiverAddress OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "IPv4/IPv6 address or host name of trap receiver." ::= { blueNet2TrapReceiverEntry 4 } blueNet2TrapReceiverFriendlyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "User friendly name to identify a trap receiver. This is a mnemonic only and will not be used to send traps." ::= { blueNet2TrapReceiverEntry 5 } blueNet2TrapReceiverDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Description to identify a trap receiver. This is a mnemonic only and will not be used to send traps." ::= { blueNet2TrapReceiverEntry 6 } blueNet2TrapReceiverCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Community used by SNMPv1 and SNMPv2c to identify at trap receiver address." ::= { blueNet2TrapReceiverEntry 7 } blueNet2TrapReceiverUsername OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Username used by SNMPv3 to identify at trap receiver address." ::= { blueNet2TrapReceiverEntry 8 } -- ----------------------------------------------------------------------------- blueNet2Modbus OBJECT IDENTIFIER ::= { blueNet2Protocols 13 } blueNet2ModbusVersions OBJECT-TYPE SYNTAX BITS { rtu (0), tcp (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Supported and enabled modbus version(s)." DEFVAL { { tcp } } ::= { blueNet2Modbus 1 } blueNet2ModbusService OBJECT-TYPE SYNTAX INTEGER { disabled (1), readonly (2), writeonly (3), readwrite (4) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Modbus service status." DEFVAL { disabled } ::= { blueNet2Modbus 2 } blueNet2ModbusTcpPort OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "TCP/IP port of modbus daemon." DEFVAL { 502 } ::= { blueNet2Modbus 3 } blueNet2ModbusSerialMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Serial mode configuration parameters (baud,data,parity,stop) of modbus daemon." DEFVAL { "115200,8,N,1" } ::= { blueNet2Modbus 4 } blueNet2MaxModbusTcpMasters OBJECT-TYPE SYNTAX Unsigned32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of entries in blueNet2ModbusTcpTable." ::= { blueNet2Modbus 5 } blueNet2ModbusTcpTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2ModbusTcpEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A list of modbus entries." ::= { blueNet2Modbus 6 } blueNet2ModbusTcpEntry OBJECT-TYPE SYNTAX BlueNet2ModbusTcpEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Entries of modbus table." INDEX { blueNet2ModbusTcpIndex } ::= { blueNet2ModbusTcpTable 1 } BlueNet2ModbusTcpEntry ::= SEQUENCE { blueNet2ModbusTcpIndex Unsigned32, blueNet2ModbusTcpRowStatus RowStatus, blueNet2ModbusTcpAccess INTEGER, blueNet2ModbusTcpMaster DisplayString, blueNet2ModbusTcpFriendlyName DisplayString, blueNet2ModbusTcpDescription DisplayString } blueNet2ModbusTcpIndex OBJECT-TYPE SYNTAX Unsigned32 (1..256) MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Index of the modbus TCP access table." ::= { blueNet2ModbusTcpEntry 1 } blueNet2ModbusTcpRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Activate/create/destroy/disable a modbus TCP entry." ::= { blueNet2ModbusTcpEntry 2 } blueNet2ModbusTcpAccess OBJECT-TYPE SYNTAX INTEGER { noaccess (1), readonly (2), writeonly (3), readwrite (4) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Modbus access for this master entry. This access is inferior to blueNet2ModbusService, e.g. readwrite access also requires readwrite status." -- DEFVAL { noaccess } ::= { blueNet2ModbusTcpEntry 3 } blueNet2ModbusTcpMaster OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Source to restrict modbus access. It can either be a specific hostname, IP address, or a subnet represented as IP/MASK (e.g. 10.10.10.0/255.255.255.0), or IP/BITS (e.g. 10.10.10.0/24), or the IPv6 equivalents. The same master can be specified in several separate entries presumably with different access tokens. The first combination matching an incoming request will be selected." ::= { blueNet2ModbusTcpEntry 4 } blueNet2ModbusTcpFriendlyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "User friendly name to identify a modbus master. This is a mnemonic only and will not be used to query data." ::= { blueNet2ModbusTcpEntry 5 } blueNet2ModbusTcpDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Description to identify a modbus master. This is a mnemonic only and will not be used to query data." ::= { blueNet2ModbusTcpEntry 6 } -- ----------------------------------------------------------------------------- blueNet2Ntp OBJECT IDENTIFIER ::= { blueNet2Protocols 14 } blueNet2NtpService OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "NTP service status." DEFVAL { disabled } ::= { blueNet2Ntp 1 } blueNet2NtpPort OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "TCP/IP port of NTP server." DEFVAL { 123 } ::= { blueNet2Ntp 2 } blueNet2NtpTimeZone OBJECT-TYPE SYNTAX Integer32 (1..107) MAX-ACCESS read-write STATUS current DESCRIPTION "Time Zone, list is sorted once by time offset and once by index 24 : (GMT-12:00) International Date Line West 99 : (GMT-11:00) Coordinated Universal Time-11 39 : (GMT-10:00) Hawaii 2 : (GMT-09:00) Alaska 58 : (GMT-08:00) Pacific Time (US & Canada) 59 : (GMT-08:00) Tijuana, Baja California 75 : (GMT-07:00) Arizona 47 : (GMT-07:00) Mountain Time (US & Canada) 48 : (GMT-07:00) Chihuahua, La Paz, Mazatlan 15 : (GMT-06:00) Central America 21 : (GMT-06:00) Central Time (US & Canada) 22 : (GMT-06:00) Guadalajara, Mexico City, Monterrey 11 : (GMT-06:00) Saskatchewan 106 : (GMT-05:30) Pacific Marquesas 63 : (GMT-05:00) Bogota, Lima, Quito, Rio Branco 29 : (GMT-05:00) Eastern Time (US & Canada) 74 : (GMT-05:00) Indiana (East) 85 : (GMT-04:00) Caracas 95 : (GMT-04:00) Asuncion 6 : (GMT-04:00) Atlantic Time (Canada) 64 : (GMT-04:00) La Paz 17 : (GMT-04:00) Manaus 57 : (GMT-04:00) Santiago 54 : (GMT-03:30) Newfoundland 28 : (GMT-03:00) Brasilia 86 : (GMT-03:00) Buenos Aires 62 : (GMT-03:00) Buenos Aires, Georgetown 36 : (GMT-03:00) Greenland 83 : (GMT-03:00) Montevideo 87 : (GMT-03:00) Salvador 45 : (GMT-02:00) Mid-Atlantic 10 : (GMT-01:00) Azores 12 : (GMT-01:00) Cape Verde Is. 93 : (GMT) Casablanca 89 : (GMT) Coordinated Universal Time 37 : (GMT) Casablanca, Monrovia, Reykjavik 35 : (GMT) Greenwich Mean Time : Dublin, Edinburgh, Lisbon, London 79 : (GMT+01:00) Amsterdam, Berlin, Bern, Rome, Stockholm, Vienna 18 : (GMT+01:00) Belgrade, Bratislava, Budapest, Ljubljana, Prague 60 : (GMT+01:00) Brussels, Copenhagen, Madrid, Paris 19 : (GMT+01:00) Sarajevo, Skopje, Warsaw, Zagreb 101 : (GMT+01:00) Tripoli 78 : (GMT+01:00) West Central Africa 43 : (GMT+02:00) Amman 38 : (GMT+02:00) Athens, Bucharest, Istanbul 46 : (GMT+02:00) Beirut 27 : (GMT+02:00) Minsk 30 : (GMT+02:00) Cairo 96 : (GMT+02:00) Damascus 68 : (GMT+02:00) Harare, Pretoria 33 : (GMT+02:00) Helsinki, Kyiv, Riga, Sofia, Tallinn, Vilnius 98 : (GMT+02:00) Istanbul 42 : (GMT+02:00) Jerusalem 51 : (GMT+02:00) Windhoek 5 : (GMT+03:00) Baghdad 90 : (GMT+03:00) Kaliningrad, Minsk 3 : (GMT+03:00) Kuwait, Riyadh 61 : (GMT+04:00) Moscow, St. Petersburg, Volgograd 92 : (GMT+04:00) Port Louis 25 : (GMT+03:00) Nairobi 34 : (GMT+03:00) Tbilisi 41 : (GMT+03:30) Tehran 4 : (GMT+04:00) Abu Dhabi, Muscat 9 : (GMT+04:00) Baku 84 : (GMT+04:00) Yerevan 13 : (GMT+04:00) Yerevan (Do not use) 1 : (GMT+04:30) Kabul 31 : (GMT+05:00) Ekaterinburg 94 : (GMT+05:00) Islamabad, Karachi 80 : (GMT+05:00) Tashkent 40 : (GMT+05:30) Chennai, Kolkata, Mumbai, New Delhi 69 : (GMT+05:30) Sri Jayawardenepura 52 : (GMT+05:45) Kathmandu 50 : (GMT+06:00) Almaty, Novosibirsk 16 : (GMT+06:00) Astana, Dhaka 88 : (GMT+06:00) Dhaka 49 : (GMT+06:30) Yangon (Rangoon) 66 : (GMT+07:00) Bangkok, Hanoi, Jakarta 56 : (GMT+07:00) Krasnoyarsk 23 : (GMT+08:00) Beijing, Chongqing, Hong Kong, Urumqi 55 : (GMT+08:00) Irkutsk, Ulaan Bataar 97 : (GMT+08:00) Ulaanbaatar 67 : (GMT+08:00) Kuala Lumpur, Singapore 77 : (GMT+08:00) Perth 70 : (GMT+08:00) Taipei 102 : (GMT+08:45) Australia, Eucla 72 : (GMT+09:00) Osaka, Sapporo, Tokyo 44 : (GMT+09:00) Seoul 82 : (GMT+09:00) Yakutsk 14 : (GMT+09:30) Adelaide 7 : (GMT+09:30) Darwin 26 : (GMT+10:00) Brisbane 8 : (GMT+10:00) Canberra, Melbourne, Sydney 81 : (GMT+10:00) Guam, Port Moresby 71 : (GMT+10:00) Hobart 76 : (GMT+10:00) Vladivostok 103 : (GMT+10:30) Australia, Lord Howe 104 : (GMT+11:30) Pacific, Norfolk 91 : (GMT+12:00) Magadan 20 : (GMT+11:00) Magadan, Solomon Is., New Caledonia 53 : (GMT+12:00) Auckland, Wellington 100 : (GMT+12:00) Coordinated Universal Time+12 32 : (GMT+12:00) Fiji, Kamchatka, Marshall Is. 105 : (GMT+12:45) Pacific, Chatham 65 : (GMT+13:00) Samoa 73 : (GMT+13:00) Nuku'alofa 107 : (GMT+14:00) Line Island 1 : (GMT+04:30) Kabul 2 : (GMT-09:00) Alaska 3 : (GMT+03:00) Kuwait, Riyadh 4 : (GMT+04:00) Abu Dhabi, Muscat 5 : (GMT+03:00) Baghdad 6 : (GMT-04:00) Atlantic Time (Canada) 7 : (GMT+09:30) Darwin 8 : (GMT+10:00) Canberra, Melbourne, Sydney 9 : (GMT+04:00) Baku 10 : (GMT-01:00) Azores 11 : (GMT-06:00) Saskatchewan 12 : (GMT-01:00) Cape Verde Is. 13 : (GMT+04:00) Yerevan (Do not use) 14 : (GMT+09:30) Adelaide 15 : (GMT-06:00) Central America 16 : (GMT+06:00) Astana, Dhaka 17 : (GMT-04:00) Manaus 18 : (GMT+01:00) Belgrade, Bratislava, Budapest, Ljubljana, Prague 19 : (GMT+01:00) Sarajevo, Skopje, Warsaw, Zagreb 20 : (GMT+11:00) Magadan, Solomon Is., New Caledonia 21 : (GMT-06:00) Central Time (US & Canada) 22 : (GMT-06:00) Guadalajara, Mexico City, Monterrey 23 : (GMT+08:00) Beijing, Chongqing, Hong Kong, Urumqi 24 : (GMT-12:00) International Date Line West 25 : (GMT+03:00) Nairobi 26 : (GMT+10:00) Brisbane 27 : (GMT+02:00) Minsk 28 : (GMT-03:00) Brasilia 29 : (GMT-05:00) Eastern Time (US & Canada) 30 : (GMT+02:00) Cairo 31 : (GMT+05:00) Ekaterinburg 32 : (GMT+12:00) Fiji, Kamchatka, Marshall Is. 33 : (GMT+02:00) Helsinki, Kyiv, Riga, Sofia, Tallinn, Vilnius 34 : (GMT+03:00) Tbilisi 35 : (GMT) Greenwich Mean Time : Dublin, Edinburgh, Lisbon, London 36 : (GMT-03:00) Greenland 37 : (GMT) Casablanca, Monrovia, Reykjavik 38 : (GMT+02:00) Athens, Bucharest, Istanbul 39 : (GMT-10:00) Hawaii 40 : (GMT+05:30) Chennai, Kolkata, Mumbai, New Delhi 41 : (GMT+03:30) Tehran 42 : (GMT+02:00) Jerusalem 43 : (GMT+02:00) Amman 44 : (GMT+09:00) Seoul 45 : (GMT-02:00) Mid-Atlantic 46 : (GMT+02:00) Beirut 47 : (GMT-07:00) Mountain Time (US & Canada) 48 : (GMT-07:00) Chihuahua, La Paz, Mazatlan 49 : (GMT+06:30) Yangon (Rangoon) 50 : (GMT+06:00) Almaty, Novosibirsk 51 : (GMT+02:00) Windhoek 52 : (GMT+05:45) Kathmandu 53 : (GMT+12:00) Auckland, Wellington 54 : (GMT-03:30) Newfoundland 55 : (GMT+08:00) Irkutsk, Ulaan Bataar 56 : (GMT+07:00) Krasnoyarsk 57 : (GMT-04:00) Santiago 58 : (GMT-08:00) Pacific Time (US & Canada) 59 : (GMT-08:00) Tijuana, Baja California 60 : (GMT+01:00) Brussels, Copenhagen, Madrid, Paris 61 : (GMT+04:00) Moscow, St. Petersburg, Volgograd 62 : (GMT-03:00) Buenos Aires, Georgetown 63 : (GMT-05:00) Bogota, Lima, Quito, Rio Branco 64 : (GMT-04:00) La Paz 65 : (GMT+13:00) Samoa 66 : (GMT+07:00) Bangkok, Hanoi, Jakarta 67 : (GMT+08:00) Kuala Lumpur, Singapore 68 : (GMT+02:00) Harare, Pretoria 69 : (GMT+05:30) Sri Jayawardenepura 70 : (GMT+08:00) Taipei 71 : (GMT+10:00) Hobart 72 : (GMT+09:00) Osaka, Sapporo, Tokyo 73 : (GMT+13:00) Nuku'alofa 74 : (GMT-05:00) Indiana (East) 75 : (GMT-07:00) Arizona 76 : (GMT+10:00) Vladivostok 77 : (GMT+08:00) Perth 78 : (GMT+01:00) West Central Africa 79 : (GMT+01:00) Amsterdam, Berlin, Bern, Rome, Stockholm, Vienna 80 : (GMT+05:00) Tashkent 81 : (GMT+10:00) Guam, Port Moresby 82 : (GMT+09:00) Yakutsk 83 : (GMT-03:00) Montevideo 84 : (GMT+04:00) Yerevan 85 : (GMT-04:00) Caracas 86 : (GMT-03:00) Buenos Aires 87 : (GMT-03:00) Salvador 88 : (GMT+06:00) Dhaka 89 : (GMT) Coordinated Universal Time 90 : (GMT+03:00) Kaliningrad, Minsk 91 : (GMT+12:00) Magadan 92 : (GMT+04:00) Port Louis 93 : (GMT) Casablanca 94 : (GMT+05:00) Islamabad, Karachi 95 : (GMT-04:00) Asuncion 96 : (GMT+02:00) Damascus 97 : (GMT+08:00) Ulaanbaatar 98 : (GMT+02:00) Istanbul 99 : (GMT-11:00) Coordinated Universal Time-11 100 : (GMT+12:00) Coordinated Universal Time+12 101 : (GMT+01:00) Tripoli 102 : (GMT+08:45) Australia, Eucla 103 : (GMT+10:30) Australia, Lord Howe 104 : (GMT+11:30) Pacific, Norfolk 105 : (GMT+12:45) Pacific, Chatham 106 : (GMT-09:30) Pacific Marquesas 107 : (GMT+14:00) Line Island The operating system may reject any unknown/unsupported timezone. The timezone may also change to another timezone with the same offset." DEFVAL { 79 } ::= { blueNet2Ntp 3 } blueNet2MaxNtpServers OBJECT-TYPE SYNTAX Unsigned32 (1..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of entries in blueNet2NtpServerTable." ::= { blueNet2Ntp 4 } blueNet2NtpServerTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2NtpServerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of NTP server entries." ::= { blueNet2Ntp 5 } blueNet2NtpServerEntry OBJECT-TYPE SYNTAX BlueNet2NtpServerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of NTP server table." INDEX { blueNet2NtpServerIndex } ::= { blueNet2NtpServerTable 1 } BlueNet2NtpServerEntry ::= SEQUENCE { blueNet2NtpServerIndex Unsigned32, blueNet2NtpServerRowStatus RowStatus, blueNet2NtpServerAddress DisplayString, blueNet2NtpServerFriendlyName DisplayString, blueNet2NtpServerDescription DisplayString } blueNet2NtpServerIndex OBJECT-TYPE SYNTAX Unsigned32 (1..3) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the NTP server table." ::= { blueNet2NtpServerEntry 1 } blueNet2NtpServerRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Activate/create/destroy/disable a NTP server entry." ::= { blueNet2NtpServerEntry 2 } blueNet2NtpServerAddress OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "IP address or name of NTP server." ::= { blueNet2NtpServerEntry 3 } blueNet2NtpServerFriendlyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "User friendly name to identify a ntp server. This is a mnemonic only and will not be used to query data." ::= { blueNet2NtpServerEntry 4 } blueNet2NtpServerDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Description to identify a ntp server. This is a mnemonic only and will not be used to query data." ::= { blueNet2NtpServerEntry 5 } -- ----------------------------------------------------------------------------- blueNet2Smtp OBJECT IDENTIFIER ::= { blueNet2Protocols 15 } blueNet2SmtpService OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "SMTP service status." DEFVAL { disabled } ::= { blueNet2Smtp 1 } blueNet2SmtpPort OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "TCP/IP port of SMTP server." DEFVAL { 25 } ::= { blueNet2Smtp 2 } blueNet2SmtpServer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "IP address or name of SMTP server." ::= { blueNet2Smtp 3 } blueNet2SmtpAuth OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "SMTP authentication mode." DEFVAL { disabled } ::= { blueNet2Smtp 4 } blueNet2SmtpUsername OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Username required to authenticate at the SMTP server." ::= { blueNet2Smtp 5 } blueNet2SmtpPassword OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Password required to authenticate at the SMTP server." ::= { blueNet2Smtp 6 } blueNet2SmtpFrom OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Sender address of the SMTP message." ::= { blueNet2Smtp 7 } blueNet2SmtpReply OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Reply address of the SMTP message." ::= { blueNet2Smtp 8 } blueNet2MaxSmtpReceivers OBJECT-TYPE SYNTAX Unsigned32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of entries in blueNet2SmtpReceiverTable." ::= { blueNet2Smtp 9 } blueNet2SmtpReceiverTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2SmtpReceiverEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A list of SMTP receiver entries." ::= { blueNet2Smtp 10 } blueNet2SmtpReceiverEntry OBJECT-TYPE SYNTAX BlueNet2SmtpReceiverEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Entries of SMTP receiver table." INDEX { blueNet2SmtpReceiverIndex } ::= { blueNet2SmtpReceiverTable 1 } BlueNet2SmtpReceiverEntry ::= SEQUENCE { blueNet2SmtpReceiverIndex Unsigned32, blueNet2SmtpReceiverRowStatus RowStatus, blueNet2SmtpReceiverAddress DisplayString, blueNet2SmtpReceiverFriendlyName DisplayString, blueNet2SmtpReceiverDescription DisplayString } blueNet2SmtpReceiverIndex OBJECT-TYPE SYNTAX Unsigned32 (1..256) MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Index of the SMTP receiver table." ::= { blueNet2SmtpReceiverEntry 1 } blueNet2SmtpReceiverRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Activate/create/destroy/disable a SMTP receiver entry." ::= { blueNet2SmtpReceiverEntry 2 } blueNet2SmtpReceiverAddress OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "IP address or name of SMTP receiver." ::= { blueNet2SmtpReceiverEntry 3 } blueNet2SmtpReceiverFriendlyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "User friendly name to identify a smtp server. This is a mnemonic only and will not be used to send data." ::= { blueNet2SmtpReceiverEntry 4 } blueNet2SmtpReceiverDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Description to identify a smtp server. This is a mnemonic only and will not be used to send data." ::= { blueNet2SmtpReceiverEntry 5 } -- ----------------------------------------------------------------------------- blueNet2Syslog OBJECT IDENTIFIER ::= { blueNet2Protocols 16 } blueNet2SyslogService OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Syslog service status." DEFVAL { disabled } ::= { blueNet2Syslog 1 } blueNet2SyslogFacility OBJECT-TYPE SYNTAX INTEGER { local0 (1), local1 (2), local2 (3), local3 (4), local4 (5), local5 (6), local6 (7), local7 (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Syslog facility local0 .. local7." DEFVAL { local0 } ::= { blueNet2Syslog 2 } blueNet2MaxSyslogServers OBJECT-TYPE SYNTAX Unsigned32 (1..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of entries in blueNet2SyslogServerTable." ::= { blueNet2Syslog 3 } blueNet2SyslogServerTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2SyslogServerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of syslog server entries." ::= { blueNet2Syslog 4 } blueNet2SyslogServerEntry OBJECT-TYPE SYNTAX BlueNet2SyslogServerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of syslog server table." INDEX { blueNet2SyslogServerIndex } ::= { blueNet2SyslogServerTable 1 } BlueNet2SyslogServerEntry ::= SEQUENCE { blueNet2SyslogServerIndex Unsigned32, blueNet2SyslogServerRowStatus RowStatus, blueNet2SyslogServerAddress DisplayString, blueNet2SyslogServerPort Unsigned32, blueNet2SyslogServerFriendlyName DisplayString, blueNet2SyslogServerDescription DisplayString, blueNet2SyslogServerProtocol INTEGER } blueNet2SyslogServerIndex OBJECT-TYPE SYNTAX Unsigned32 (1..3) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of the syslog server table." ::= { blueNet2SyslogServerEntry 1 } blueNet2SyslogServerRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Activate/create/destroy/disable a syslog server entry." ::= { blueNet2SyslogServerEntry 2 } blueNet2SyslogServerAddress OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "IP address or name of syslog server." ::= { blueNet2SyslogServerEntry 3 } blueNet2SyslogServerPort OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "TCP/IP port of syslog server." DEFVAL { 514 } ::= { blueNet2SyslogServerEntry 4 } blueNet2SyslogServerFriendlyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "User friendly name to identify a syslog server. This is a mnemonic only and will not be used to send data." ::= { blueNet2SyslogServerEntry 5 } blueNet2SyslogServerDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Description to identify a syslog server. This is a mnemonic only and will not be used to send data." ::= { blueNet2SyslogServerEntry 6 } blueNet2SyslogServerProtocol OBJECT-TYPE SYNTAX INTEGER { udp (1), tcp (2), relp (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set TCP/IP protocol of syslog server." DEFVAL { udp } ::= { blueNet2SyslogServerEntry 7 } -- ============================================================================= -- blueNet2Devices: global BlueNet2 PDU devices -- blueNet2DeviceInfo OBJECT IDENTIFIER ::= { blueNet2Devices 1 } blueNet2OverallDeviceStatus OBJECT-TYPE SYNTAX BlueNet2ComponentStates MAX-ACCESS read-only STATUS current DESCRIPTION "Overall status of all devices." ::= { blueNet2DeviceInfo 1 } blueNet2NumberOfDevices OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of devices available." ::= { blueNet2DeviceInfo 2 } blueNet2LastChangeOverallDeviceStatus OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last status change of any device connected to BlueNet2 PDU according to operating time sysUpTime." ::= { blueNet2DeviceInfo 3 } blueNet2LastChangeNumberOfDevices OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last device number change according to operating time sysUpTime." ::= { blueNet2DeviceInfo 4 } blueNet2LastChangeDeviceSettings OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last setting change of any device connected to BlueNet2 PDU according to operating time sysUpTime. This timestamp will be affected by SNMP settings only!" ::= { blueNet2DeviceInfo 5 } blueNet2LastChangeDevices OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last device change according to operating time sysUpTime." ::= { blueNet2DeviceInfo 6 } blueNet2DevicesAccumulatedStatus OBJECT-TYPE SYNTAX BlueNet2EntityBits MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field of all current device states." ::= { blueNet2DeviceInfo 7 } -- ----------------------------------------------------------------------------- blueNet2DeviceTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2DeviceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Headline of device table." ::= { blueNet2Devices 2 } blueNet2DeviceEntry OBJECT-TYPE SYNTAX BlueNet2DeviceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of device table." INDEX { blueNet2DeviceIndex } ::= { blueNet2DeviceTable 1 } BlueNet2DeviceEntry ::= SEQUENCE { blueNet2DeviceIndex Unsigned32, blueNet2DeviceGuid OCTET STRING, blueNet2DeviceName DisplayString, blueNet2DeviceFriendlyName DisplayString, blueNet2DeviceDescription DisplayString, blueNet2DeviceType OBJECT IDENTIFIER, blueNet2DeviceStatus BlueNet2EntityStates, blueNet2DeviceAlarm DisplayString, blueNet2DeviceLastChange TimeTicks, blueNet2DeviceEntPhysicalIndex Unsigned32, blueNet2DevicePartNr DisplayString, blueNet2DeviceSNr DisplayString, blueNet2DeviceFwV DisplayString, blueNet2DeviceHwV DisplayString, blueNet2DeviceSwV DisplayString, blueNet2DeviceOsV DisplayString, blueNet2DeviceMAC DisplayString, blueNet2DeviceNumberOfSensors Unsigned32, blueNet2DeviceNumberOfCircuits Unsigned32, blueNet2DeviceNumberOfPhases Unsigned32, blueNet2DeviceNumberOfFuses Unsigned32, blueNet2DeviceNumberOfSockets Unsigned32, blueNet2DeviceNumberOfRCMs Unsigned32, blueNet2DeviceNumberOfVars Unsigned32, blueNet2DeviceLocation DisplayString, blueNet2DeviceProductDate DisplayString, blueNet2DeviceModbusAddr Integer32, blueNet2DeviceNumberOfSPDs Unsigned32 } blueNet2DeviceIndex OBJECT-TYPE SYNTAX Unsigned32 (1..11) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of device connected to BlueNet2 PDU." ::= { blueNet2DeviceEntry 1 } blueNet2DeviceGuid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "GUID of device connected to BlueNet2 PDU." ::= { blueNet2DeviceEntry 2 } blueNet2DeviceName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the device connected to BlueNet2 PDU." ::= { blueNet2DeviceEntry 3 } blueNet2DeviceFriendlyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "User friendlyname of the device connected to BlueNet2 PDU." ::= { blueNet2DeviceEntry 4 } blueNet2DeviceDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "Description of the device connected to BlueNet2 PDU." ::= { blueNet2DeviceEntry 5 } blueNet2DeviceType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "Type of device connected to BlueNet2 PDU." ::= { blueNet2DeviceEntry 6 } blueNet2DeviceStatus OBJECT-TYPE SYNTAX BlueNet2EntityStates MAX-ACCESS read-only STATUS current DESCRIPTION "General status of device connected to BlueNet2 PDU." ::= { blueNet2DeviceEntry 7 } blueNet2DeviceAlarm OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Alarm text of device connected to BlueNet2 PDU. This field is deprecated and is not filled." ::= { blueNet2DeviceEntry 8 } blueNet2DeviceLastChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last change of device connected to BlueNet2 PDU according to operating time sysUpTime." ::= { blueNet2DeviceEntry 9 } blueNet2DeviceEntPhysicalIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Corresponding entPhysicalIndex of this device. 0 if none exists." ::= { blueNet2DeviceEntry 10 } blueNet2DevicePartNr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Article part number of device connected to BlueNet2 PDU." ::= { blueNet2DeviceEntry 11 } blueNet2DeviceSNr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number of device connected to BlueNet2 PDU." ::= { blueNet2DeviceEntry 12 } blueNet2DeviceFwV OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Firmware version of device connected to BlueNet2 PDU." ::= { blueNet2DeviceEntry 13 } blueNet2DeviceHwV OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware version of device connected to BlueNet2 PDU." ::= { blueNet2DeviceEntry 14 } blueNet2DeviceSwV OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Software version of device connected to BlueNet2 PDU." ::= { blueNet2DeviceEntry 15 } blueNet2DeviceOsV OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Operating system version of device connected to BlueNet2 PDU." ::= { blueNet2DeviceEntry 16 } blueNet2DeviceMAC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "MAC address of device connected to BlueNet2 PDU." ::= { blueNet2DeviceEntry 17 } blueNet2DeviceNumberOfSensors OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of sensors available on this device. This variable will give the number of rows of the sensor table blueNet2SensorTable belonging to this device." ::= { blueNet2DeviceEntry 18 } blueNet2DeviceNumberOfCircuits OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of circuits available in this device. This variable will give the number of rows of the circuit table blueNet2CircuitTable belonging to this device." ::= { blueNet2DeviceEntry 19 } blueNet2DeviceNumberOfPhases OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of phases available in this device. This variable will give the number of rows of the phases table blueNet2PhaseTable belonging to this device." ::= { blueNet2DeviceEntry 20 } blueNet2DeviceNumberOfFuses OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of fuses available in this device. This variable will give the number of rows of the fuse table blueNet2FuseTable belonging to this device." ::= { blueNet2DeviceEntry 21 } blueNet2DeviceNumberOfSockets OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of sockets available in this device. This variable will give the number of rows of the socket table blueNet2SocketTable belonging to this device." ::= { blueNet2DeviceEntry 22 } blueNet2DeviceNumberOfRCMs OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of RCMs available in this device. This variable will give the number of rows of the RCM table blueNet2RcmTable belonging to this device." ::= { blueNet2DeviceEntry 23 } blueNet2DeviceNumberOfVars OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of variables available in this device. This variable will give the number of rows of the variable table blueNet2VariableTable belonging to this device." ::= { blueNet2DeviceEntry 24 } blueNet2DeviceLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "Location of device connected to BlueNet2 PDU." ::= { blueNet2DeviceEntry 25 } blueNet2DeviceProductDate OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Device Production Date." ::= { blueNet2DeviceEntry 26 } blueNet2DeviceModbusAddr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Device Modbus Address." ::= { blueNet2DeviceEntry 27 } blueNet2DeviceNumberOfSPDs OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of SPDs available in this device. This variable will give the number of rows of the SPD table blueNet2SpdTable belonging to this device." ::= { blueNet2DeviceEntry 28 } -- ============================================================================= -- blueNet2Sensors: BlueNet2 PDU sensors -- blueNet2SensorInfo OBJECT IDENTIFIER ::= { blueNet2Sensors 1 } blueNet2OverallSensorStatus OBJECT-TYPE SYNTAX BlueNet2ComponentStates MAX-ACCESS read-only STATUS current DESCRIPTION "Overall status of all sensors." ::= { blueNet2SensorInfo 1 } blueNet2NumberOfSensors OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of sensors available." ::= { blueNet2SensorInfo 2 } blueNet2LastChangeOverallSensorStatus OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last status change of any sensor connected to BlueNet2 PDU according to operating time sysUpTime." ::= { blueNet2SensorInfo 3 } blueNet2LastChangeNumberOfSensors OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last sensor number change according to operating time sysUpTime." ::= { blueNet2SensorInfo 4 } blueNet2LastChangeSensorSettings OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last setting change of any sensor connected to BlueNet2 PDU according to operating time sysUpTime. This timestamp will be affected by SNMP settings only!" ::= { blueNet2SensorInfo 5 } blueNet2LastChangeSensors OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last sensor change according to operating time sysUpTime." ::= { blueNet2SensorInfo 6 } blueNet2SensorsAccumulatedStatus OBJECT-TYPE SYNTAX BlueNet2EntityBits MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field of all current sensor states." ::= { blueNet2SensorInfo 7 } -- ----------------------------------------------------------------------------- blueNet2SensorTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2SensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Headline of sensor table." ::= { blueNet2Sensors 2 } blueNet2SensorEntry OBJECT-TYPE SYNTAX BlueNet2SensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of sensor table." INDEX { blueNet2SensorDevice,blueNet2SensorIndex } ::= { blueNet2SensorTable 1 } BlueNet2SensorEntry ::= SEQUENCE { blueNet2SensorDevice Unsigned32, blueNet2SensorIndex Unsigned32, blueNet2SensorGuid OCTET STRING, blueNet2SensorName DisplayString, blueNet2SensorFriendlyName DisplayString, blueNet2SensorDescription DisplayString, blueNet2SensorType OBJECT IDENTIFIER, blueNet2SensorStatus BlueNet2EntityStates, blueNet2SensorAlarm DisplayString, blueNet2SensorLastChange TimeTicks, blueNet2SensorEntPhysicalIndex Unsigned32, blueNet2SensorNumberOfVars Unsigned32, blueNet2SensorHwV DisplayString, blueNet2SensorFwV DisplayString, blueNet2SensorSNr DisplayString } blueNet2SensorDevice OBJECT-TYPE SYNTAX Unsigned32 (1..11) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of device connected to BlueNet2 PDU." ::= { blueNet2SensorEntry 1 } blueNet2SensorIndex OBJECT-TYPE SYNTAX Unsigned32 (1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of sensor connected to BlueNet2 PDU." ::= { blueNet2SensorEntry 2 } blueNet2SensorGuid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "GUID of sensor connected to BlueNet2 PDU." ::= { blueNet2SensorEntry 3 } blueNet2SensorName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the sensor connected to BlueNet2 PDU." ::= { blueNet2SensorEntry 4 } blueNet2SensorFriendlyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "User friendlyname of the sensor connected to BlueNet2 PDU." ::= { blueNet2SensorEntry 5 } blueNet2SensorDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "Description of the sensor connected to BlueNet2 PDU." ::= { blueNet2SensorEntry 6 } blueNet2SensorType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "Type of of sensor connected to BlueNet2 PDU." ::= { blueNet2SensorEntry 7 } blueNet2SensorStatus OBJECT-TYPE SYNTAX BlueNet2EntityStates MAX-ACCESS read-only STATUS current DESCRIPTION "General Status of sensor connected to BlueNet2 PDU." ::= { blueNet2SensorEntry 8 } blueNet2SensorAlarm OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm text of sensor connected to BlueNet2 PDU." ::= { blueNet2SensorEntry 9 } blueNet2SensorLastChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last change of sensor connected to BlueNet2 PDU according to operating time sysUpTime." ::= { blueNet2SensorEntry 10 } blueNet2SensorEntPhysicalIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Corresponding entPhysicalIndex of this sensor. 0 if none exists." ::= { blueNet2SensorEntry 11 } blueNet2SensorNumberOfVars OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of variables available on this sensor. This variable will give the number of rows of the variable table blueNet2SensorVarTable belonging to this sensor." ::= { blueNet2SensorEntry 12 } blueNet2SensorHwV OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware version of the sensor." ::= { blueNet2SensorEntry 13 } blueNet2SensorFwV OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Firmware version of the sensor." ::= { blueNet2SensorEntry 14 } blueNet2SensorSNr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Serial number of the sensor." ::= { blueNet2SensorEntry 15 } -- ----------------------------------------------------------------------------- blueNet2SensorVariableTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2SensorVariableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Headline of sensor variable table." ::= { blueNet2Sensors 3 } blueNet2SensorVariableEntry OBJECT-TYPE SYNTAX BlueNet2SensorVariableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of sensor variable table." INDEX { blueNet2SensorDeviceIndex,blueNet2SensorSensorIndex,blueNet2SensorVariableIndex } ::= { blueNet2SensorVariableTable 1 } BlueNet2SensorVariableEntry ::= SEQUENCE { blueNet2SensorDeviceIndex Unsigned32, blueNet2SensorSensorIndex Unsigned32, blueNet2SensorVariableIndex Unsigned32, blueNet2SensorVariableGuid OCTET STRING, blueNet2SensorVariableName DisplayString, blueNet2SensorVariableFriendlyName DisplayString, blueNet2SensorVariableDescription DisplayString, blueNet2SensorVariableGPIOMode BlueNet2GPIOModes, blueNet2SensorVariableGPIOSwitch BlueNet2GPIOSwitch, blueNet2SensorVariableGPIOState BlueNet2EntityStates } blueNet2SensorDeviceIndex OBJECT-TYPE SYNTAX Unsigned32 (1..11) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of sensor connected." ::= { blueNet2SensorVariableEntry 1 } blueNet2SensorSensorIndex OBJECT-TYPE SYNTAX Unsigned32 (1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of sensor connected." ::= { blueNet2SensorVariableEntry 2 } blueNet2SensorVariableIndex OBJECT-TYPE SYNTAX Unsigned32 (1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of sensor variable." ::= { blueNet2SensorVariableEntry 3 } blueNet2SensorVariableGuid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "GUID of sensor connected to BlueNet2 PDU." ::= { blueNet2SensorVariableEntry 4 } blueNet2SensorVariableName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the sensor variable." ::= { blueNet2SensorVariableEntry 5 } blueNet2SensorVariableFriendlyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "User friendlyname of the sensor variable." ::= { blueNet2SensorVariableEntry 6 } blueNet2SensorVariableDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Description of the sensor variable." ::= { blueNet2SensorVariableEntry 7 } blueNet2SensorVariableGPIOMode OBJECT-TYPE SYNTAX BlueNet2GPIOModes MAX-ACCESS read-write STATUS current DESCRIPTION "Mode of the GPIO sensor connected to BlueNet2 PDU." ::= { blueNet2SensorVariableEntry 8 } blueNet2SensorVariableGPIOSwitch OBJECT-TYPE SYNTAX BlueNet2GPIOSwitch MAX-ACCESS read-write STATUS current DESCRIPTION "Switch on/off the GPIO Outputs." ::= { blueNet2SensorVariableEntry 9 } blueNet2SensorVariableGPIOState OBJECT-TYPE SYNTAX BlueNet2EntityStates MAX-ACCESS read-only STATUS current DESCRIPTION "State of GPIO inputs/outputs" ::= { blueNet2SensorVariableEntry 10 } -- ============================================================================= -- blueNet2Circuits: BlueNet2 PDU Circuits -- blueNet2CircuitInfo OBJECT IDENTIFIER ::= { blueNet2Circuits 1 } blueNet2OverallCircuitStatus OBJECT-TYPE SYNTAX BlueNet2ComponentStates MAX-ACCESS read-only STATUS current DESCRIPTION "Overall status of all circuits." ::= { blueNet2CircuitInfo 1 } blueNet2NumberOfCircuits OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of circuits available." ::= { blueNet2CircuitInfo 2 } blueNet2LastChangeOverallCircuitStatus OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last status change of any circuit connected to BlueNet2 PDU according to operating time sysUpTime." ::= { blueNet2CircuitInfo 3 } blueNet2LastChangeNumberOfCircuits OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last circuit number change according to operating time sysUpTime." ::= { blueNet2CircuitInfo 4 } blueNet2LastChangeCircuitSettings OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last setting change of any circuit connected to BlueNet2 PDU according to operating time sysUpTime. This timestamp will be affected by SNMP settings only!" ::= { blueNet2CircuitInfo 5 } blueNet2LastChangeCircuits OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last circuit change according to operating time sysUpTime." ::= { blueNet2CircuitInfo 6 } -- ----------------------------------------------------------------------------- blueNet2CircuitTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2CircuitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Headline of circuit table." ::= { blueNet2Circuits 2 } blueNet2CircuitEntry OBJECT-TYPE SYNTAX BlueNet2CircuitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of circuit table." INDEX { blueNet2CircuitDevice,blueNet2CircuitIndex } ::= { blueNet2CircuitTable 1 } BlueNet2CircuitEntry ::= SEQUENCE { blueNet2CircuitDevice Unsigned32, blueNet2CircuitIndex Unsigned32, blueNet2CircuitGuid OCTET STRING, blueNet2CircuitName DisplayString, blueNet2CircuitFriendlyName DisplayString, blueNet2CircuitDescription DisplayString, blueNet2CircuitType OBJECT IDENTIFIER, blueNet2CircuitStatus BlueNet2EntityStates, blueNet2CircuitNumberOfPhases Unsigned32 } blueNet2CircuitDevice OBJECT-TYPE SYNTAX Unsigned32 (1..11) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of device connected to BlueNet2 PDU." ::= { blueNet2CircuitEntry 1 } blueNet2CircuitIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of circuit connected to BlueNet2 PDU." ::= { blueNet2CircuitEntry 2 } blueNet2CircuitGuid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "GUID of circuit connected to BlueNet2 PDU." ::= { blueNet2CircuitEntry 3 } blueNet2CircuitName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the circuit connected to BlueNet2 PDU." ::= { blueNet2CircuitEntry 4 } blueNet2CircuitFriendlyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "User friendlyname of the circuit connected to BlueNet2 PDU." ::= { blueNet2CircuitEntry 5 } blueNet2CircuitDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "Description of the circuit connected to BlueNet2 PDU." ::= { blueNet2CircuitEntry 6 } blueNet2CircuitType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "Type of circuit connected to BlueNet2 PDU." ::= { blueNet2CircuitEntry 7 } blueNet2CircuitStatus OBJECT-TYPE SYNTAX BlueNet2EntityStates MAX-ACCESS read-only STATUS current DESCRIPTION "General status of the entity providing the status of a circuit connected to BlueNet2 PDU in blueNet2VariableStatus." ::= { blueNet2CircuitEntry 8 } blueNet2CircuitNumberOfPhases OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of phases of circuit connected to BlueNet2 PDU." ::= { blueNet2CircuitEntry 9 } -- ----------------------------------------------------------------------------- blueNet2PhaseTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2PhaseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Headline of phase table." ::= { blueNet2Circuits 3 } blueNet2PhaseEntry OBJECT-TYPE SYNTAX BlueNet2PhaseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of phase table." INDEX { blueNet2PhaseDevice,blueNet2PhaseCircuit,blueNet2PhaseIndex } ::= { blueNet2PhaseTable 1 } BlueNet2PhaseEntry ::= SEQUENCE { blueNet2PhaseDevice Unsigned32, blueNet2PhaseCircuit Unsigned32, blueNet2PhaseIndex Unsigned32, blueNet2PhaseGuid OCTET STRING, blueNet2PhaseName DisplayString, blueNet2PhaseFriendlyName DisplayString, blueNet2PhaseDescription DisplayString, blueNet2PhaseStatus BlueNet2EntityStates, blueNet2PhaseNumberOfFuses Unsigned32 } blueNet2PhaseDevice OBJECT-TYPE SYNTAX Unsigned32 (1..11) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of device connected to BlueNet2 PDU." ::= { blueNet2PhaseEntry 1 } blueNet2PhaseCircuit OBJECT-TYPE SYNTAX Unsigned32 (1..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of circuit connected to BlueNet2 PDU." ::= { blueNet2PhaseEntry 2 } blueNet2PhaseIndex OBJECT-TYPE SYNTAX Unsigned32 (1..3) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of phase connected to BlueNet2 PDU." ::= { blueNet2PhaseEntry 3 } blueNet2PhaseGuid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "GUID of phase connected to BlueNet2 PDU." ::= { blueNet2PhaseEntry 4 } blueNet2PhaseName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the phase connected to BlueNet2 PDU." ::= { blueNet2PhaseEntry 5 } blueNet2PhaseFriendlyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "User friendlyname of the phase connected to BlueNet2 PDU." ::= { blueNet2PhaseEntry 6 } blueNet2PhaseDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "Description of the phase connected to BlueNet2 PDU." ::= { blueNet2PhaseEntry 7 } blueNet2PhaseStatus OBJECT-TYPE SYNTAX BlueNet2EntityStates MAX-ACCESS read-only STATUS current DESCRIPTION "General status of the entity providing the status of a phase connected to BlueNet2 PDU in blueNet2VariableStatus." ::= { blueNet2PhaseEntry 8 } blueNet2PhaseNumberOfFuses OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of fuses of phase connected to BlueNet2 PDU." ::= { blueNet2PhaseEntry 9 } -- ----------------------------------------------------------------------------- blueNet2FuseTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2FuseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Headline of fuse table." ::= { blueNet2Circuits 4 } blueNet2FuseEntry OBJECT-TYPE SYNTAX BlueNet2FuseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of fuse table." INDEX { blueNet2FuseDevice,blueNet2FuseCircuit,blueNet2FusePhase,blueNet2FuseIndex } ::= { blueNet2FuseTable 1 } BlueNet2FuseEntry ::= SEQUENCE { blueNet2FuseDevice Unsigned32, blueNet2FuseCircuit Unsigned32, blueNet2FusePhase Unsigned32, blueNet2FuseIndex Unsigned32, blueNet2FuseGuid OCTET STRING, blueNet2FuseName DisplayString, blueNet2FuseFriendlyName DisplayString, blueNet2FuseDescription DisplayString, blueNet2FuseType OBJECT IDENTIFIER, blueNet2FuseStatus BlueNet2EntityStates, blueNet2FuseNumberOfSockets Unsigned32 } blueNet2FuseDevice OBJECT-TYPE SYNTAX Unsigned32 (1..11) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of device connected to BlueNet2 PDU." ::= { blueNet2FuseEntry 1 } blueNet2FuseCircuit OBJECT-TYPE SYNTAX Unsigned32 (1..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of circuit connected to BlueNet2 PDU." ::= { blueNet2FuseEntry 2 } blueNet2FusePhase OBJECT-TYPE SYNTAX Unsigned32 (1..3) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of phase connected to BlueNet2 PDU." ::= { blueNet2FuseEntry 3 } blueNet2FuseIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of phase connected to BlueNet2 PDU." ::= { blueNet2FuseEntry 4 } blueNet2FuseGuid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "GUID of fuse connected to BlueNet2 PDU." ::= { blueNet2FuseEntry 5 } blueNet2FuseName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the fuse connected to BlueNet2 PDU." ::= { blueNet2FuseEntry 6 } blueNet2FuseFriendlyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "User friendlyname of the fuse connected to BlueNet2 PDU." ::= { blueNet2FuseEntry 7 } blueNet2FuseDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "Description of the fuse connected to BlueNet2 PDU." ::= { blueNet2FuseEntry 8 } blueNet2FuseType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the fuse connected to BlueNet2 PDU." ::= { blueNet2FuseEntry 9 } blueNet2FuseStatus OBJECT-TYPE SYNTAX BlueNet2EntityStates MAX-ACCESS read-only STATUS current DESCRIPTION "General status of the entity providing the status of a fuse connected to BlueNet2 PDU in blueNet2VariableStatus." ::= { blueNet2FuseEntry 10 } blueNet2FuseNumberOfSockets OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of sockets of fuse connected to BlueNet2 PDU." ::= { blueNet2FuseEntry 11 } -- ----------------------------------------------------------------------------- blueNet2SocketTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2SocketEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Headline of socket table." ::= { blueNet2Circuits 5 } blueNet2SocketEntry OBJECT-TYPE SYNTAX BlueNet2SocketEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of socket table." INDEX { blueNet2SocketDevice,blueNet2SocketCircuit,blueNet2SocketPhase,blueNet2SocketIndex } ::= { blueNet2SocketTable 1 } BlueNet2SocketEntry ::= SEQUENCE { blueNet2SocketDevice Unsigned32, blueNet2SocketCircuit Unsigned32, blueNet2SocketPhase Unsigned32, blueNet2SocketFuse Unsigned32, blueNet2SocketIndex Unsigned32, blueNet2SocketGuid OCTET STRING, blueNet2SocketName DisplayString, blueNet2SocketFriendlyName DisplayString, blueNet2SocketDescription DisplayString, blueNet2SocketType OBJECT IDENTIFIER, blueNet2SocketStatus BlueNet2EntityStates, blueNet2SocketMode BlueNet2SocketModes, blueNet2SocketIdentify BlueNet2SocketModes, blueNet2SocketMemberIndex Unsigned32 } blueNet2SocketDevice OBJECT-TYPE SYNTAX Unsigned32 (1..11) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of device connected to BlueNet2 PDU." ::= { blueNet2SocketEntry 1 } blueNet2SocketCircuit OBJECT-TYPE SYNTAX Unsigned32 (1..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of circuit connected to BlueNet2 PDU." ::= { blueNet2SocketEntry 2 } blueNet2SocketPhase OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of phase connected to BlueNet2 PDU." ::= { blueNet2SocketEntry 3 } blueNet2SocketFuse OBJECT-TYPE SYNTAX Unsigned32 (1..4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of fuse connected to BlueNet2 PDU." ::= { blueNet2SocketEntry 4 } blueNet2SocketIndex OBJECT-TYPE SYNTAX Unsigned32 (0..24) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of socket connected to BlueNet2 PDU." ::= { blueNet2SocketEntry 5 } blueNet2SocketGuid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "GUID of socket connected to BlueNet2 PDU." ::= { blueNet2SocketEntry 6 } blueNet2SocketName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the socket connected to BlueNet2 PDU." ::= { blueNet2SocketEntry 7 } blueNet2SocketFriendlyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "User friendlyname of the socket connected to BlueNet2 PDU." ::= { blueNet2SocketEntry 8 } blueNet2SocketDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "Description of the socket connected to BlueNet2 PDU." ::= { blueNet2SocketEntry 9 } blueNet2SocketType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the socket connected to BlueNet2 PDU." ::= { blueNet2SocketEntry 10 } blueNet2SocketStatus OBJECT-TYPE SYNTAX BlueNet2EntityStates MAX-ACCESS read-only STATUS current DESCRIPTION "General status of the entity providing the status of a socket connected to BlueNet2 PDU in blueNet2VariableStatus." ::= { blueNet2SocketEntry 11 } blueNet2SocketMode OBJECT-TYPE SYNTAX BlueNet2SocketModes MAX-ACCESS read-write STATUS current DESCRIPTION "Mode of the socket connected to BlueNet2 PDU." ::= { blueNet2SocketEntry 12 } blueNet2SocketIdentify OBJECT-TYPE SYNTAX BlueNet2SocketModes MAX-ACCESS read-write STATUS current DESCRIPTION "Mode of the sockets LED connected to BlueNet2 PDU." ::= { blueNet2SocketEntry 13 } blueNet2SocketMemberIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2048) MAX-ACCESS read-only STATUS current DESCRIPTION "Index of this socket to be used in blueNet2SocketGroupMembers." ::= { blueNet2SocketEntry 14 } -- ----------------------------------------------------------------------------- blueNet2RcmTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2RCMEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Headline of rcm table." ::= { blueNet2Circuits 6 } blueNet2RcmEntry OBJECT-TYPE SYNTAX BlueNet2RCMEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of rcm table." INDEX { blueNet2RcmDevice,blueNet2RcmCircuit,blueNet2RcmPhase,blueNet2RcmFuse,blueNet2RcmSocket,blueNet2RcmIndex } ::= { blueNet2RcmTable 1 } BlueNet2RCMEntry ::= SEQUENCE { blueNet2RcmDevice Unsigned32, blueNet2RcmCircuit Unsigned32, blueNet2RcmPhase Unsigned32, blueNet2RcmFuse Unsigned32, blueNet2RcmSocket Unsigned32, blueNet2RcmIndex Unsigned32, blueNet2RcmGuid OCTET STRING, blueNet2RcmName DisplayString, blueNet2RcmFriendlyName DisplayString, blueNet2RcmDescription DisplayString, blueNet2RcmType OBJECT IDENTIFIER, blueNet2RcmStatus BlueNet2EntityStates, blueNet2RcmSelftestCommand BlueNet2RcmSelftestCommand, blueNet2RcmSelftestResultValue BlueNet2RcmSelftestResult, blueNet2RcmSelftestResultACvalue BlueNet2RcmSelftestResult, blueNet2RcmSelftestResultDCvalue BlueNet2RcmSelftestResult, blueNet2RcmSelftestTimeStamp DateAndTime, blueNet2RcmSelftestResultStr DisplayString } blueNet2RcmDevice OBJECT-TYPE SYNTAX Unsigned32 (0..11) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of device connected to BlueNet2 PDU." ::= { blueNet2RcmEntry 1 } blueNet2RcmCircuit OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of circuit connected to BlueNet2 PDU." ::= { blueNet2RcmEntry 2 } blueNet2RcmPhase OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of phase connected to BlueNet2 PDU." ::= { blueNet2RcmEntry 3 } blueNet2RcmFuse OBJECT-TYPE SYNTAX Unsigned32 (0..4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of fuse connected to BlueNet2 PDU." ::= { blueNet2RcmEntry 4 } blueNet2RcmSocket OBJECT-TYPE SYNTAX Unsigned32 (0..24) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of socket connected to BlueNet2 PDU." ::= { blueNet2RcmEntry 5 } blueNet2RcmIndex OBJECT-TYPE SYNTAX Unsigned32 (0..24) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of RCM connected to BlueNet2 PDU." ::= { blueNet2RcmEntry 6 } blueNet2RcmGuid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "GUID of RCM connected to BlueNet2 PDU." ::= { blueNet2RcmEntry 7 } blueNet2RcmName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the RCM connected to BlueNet2 PDU." ::= { blueNet2RcmEntry 8 } blueNet2RcmFriendlyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "User friendlyname of the RCM connected to BlueNet2 PDU." ::= { blueNet2RcmEntry 9 } blueNet2RcmDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "Description of the RCM connected to BlueNet2 PDU." ::= { blueNet2RcmEntry 10 } blueNet2RcmType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the rcm connected to BlueNet2 PDU." ::= { blueNet2RcmEntry 11 } blueNet2RcmStatus OBJECT-TYPE SYNTAX BlueNet2EntityStates MAX-ACCESS read-only STATUS current DESCRIPTION "General status of the entity providing the status of a Rcm connected to BlueNet2 PDU in blueNet2VariableStatus." ::= { blueNet2RcmEntry 12 } blueNet2RcmSelftestCommand OBJECT-TYPE SYNTAX BlueNet2RcmSelftestCommand MAX-ACCESS read-write STATUS current DESCRIPTION "RCM self-test commands." ::= { blueNet2RcmEntry 13 } blueNet2RcmSelftestResultValue OBJECT-TYPE SYNTAX BlueNet2RcmSelftestResult MAX-ACCESS read-only STATUS current DESCRIPTION "RCM self-test result value." ::= { blueNet2RcmEntry 14 } blueNet2RcmSelftestResultACvalue OBJECT-TYPE SYNTAX BlueNet2RcmSelftestResult MAX-ACCESS read-only STATUS current DESCRIPTION "RCM self-test AC result value." ::= { blueNet2RcmEntry 15 } blueNet2RcmSelftestResultDCvalue OBJECT-TYPE SYNTAX BlueNet2RcmSelftestResult MAX-ACCESS read-only STATUS current DESCRIPTION "RCM self-test DC result value." ::= { blueNet2RcmEntry 16 } blueNet2RcmSelftestTimeStamp OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of RCM self-test." ::= { blueNet2RcmEntry 17 } blueNet2RcmSelftestResultStr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "RCM Selftest result as string." ::= { blueNet2RcmEntry 18 } -- ----------------------------------------------------------------------------- blueNet2SpdTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2SpdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Headline of SPD table." ::= { blueNet2Circuits 7 } blueNet2SpdEntry OBJECT-TYPE SYNTAX BlueNet2SpdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of spd table." INDEX { blueNet2SpdDevice,blueNet2SpdCircuit,blueNet2SpdPhase,blueNet2SpdFuse,blueNet2SpdSocket,blueNet2SpdIndex } ::= { blueNet2SpdTable 1 } BlueNet2SpdEntry ::= SEQUENCE { blueNet2SpdDevice Unsigned32, blueNet2SpdCircuit Unsigned32, blueNet2SpdPhase Unsigned32, blueNet2SpdFuse Unsigned32, blueNet2SpdSocket Unsigned32, blueNet2SpdIndex Unsigned32, blueNet2SpdGuid OCTET STRING, blueNet2SpdName DisplayString, blueNet2SpdFriendlyName DisplayString, blueNet2SpdDescription DisplayString, blueNet2SpdType OBJECT IDENTIFIER, blueNet2SpdStatus BlueNet2EntityStates } blueNet2SpdDevice OBJECT-TYPE SYNTAX Unsigned32 (1..11) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of device connected to BlueNet2 PDU." ::= { blueNet2SpdEntry 1 } blueNet2SpdCircuit OBJECT-TYPE SYNTAX Unsigned32 (1..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of circuit connected to BlueNet2 PDU." ::= { blueNet2SpdEntry 2 } blueNet2SpdPhase OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of phase connected to BlueNet2 PDU." ::= { blueNet2SpdEntry 3 } blueNet2SpdFuse OBJECT-TYPE SYNTAX Unsigned32 (0..4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of fuse connected to BlueNet2 PDU." ::= { blueNet2SpdEntry 4 } blueNet2SpdSocket OBJECT-TYPE SYNTAX Unsigned32 (0..48) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of socket connected to BlueNet2 PDU." ::= { blueNet2SpdEntry 5 } blueNet2SpdIndex OBJECT-TYPE SYNTAX Unsigned32 (1..3) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of SPD connected to BlueNet2 PDU." ::= { blueNet2SpdEntry 6 } blueNet2SpdGuid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "GUID of SPD connected to BlueNet2 PDU." ::= { blueNet2SpdEntry 7 } blueNet2SpdName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the SPD connected to BlueNet2 PDU." ::= { blueNet2SpdEntry 8 } blueNet2SpdFriendlyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "User friendlyname of the SPD connected to BlueNet2 PDU." ::= { blueNet2SpdEntry 9 } blueNet2SpdDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "Description of the SPD connected to BlueNet2 PDU." ::= { blueNet2SpdEntry 10 } blueNet2SpdType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the spd connected to BlueNet2 PDU." ::= { blueNet2SpdEntry 11 } blueNet2SpdStatus OBJECT-TYPE SYNTAX BlueNet2EntityStates MAX-ACCESS read-only STATUS current DESCRIPTION "General status of the entity providing the status of an SPD connected to BlueNet2 PDU." ::= { blueNet2SpdEntry 12 } -- ============================================================================= -- blueNet2SocketGroups: global BlueNet2 PDU SocketGroups -- blueNet2SocketGroupInfo OBJECT IDENTIFIER ::= { blueNet2SocketGroups 1 } blueNet2OverallSocketGroupStatus OBJECT-TYPE SYNTAX BlueNet2ComponentStates MAX-ACCESS read-only STATUS current DESCRIPTION "Overall status of all socket groups." ::= { blueNet2SocketGroupInfo 1 } blueNet2NumberOfSocketGroups OBJECT-TYPE SYNTAX Unsigned32 (1..128) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of socket groups available." ::= { blueNet2SocketGroupInfo 2 } blueNet2LastChangeOverallSocketGroupStatus OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last status change of any socket group connected to BlueNet2 PDU according to operating time sysUpTime." ::= { blueNet2SocketGroupInfo 3 } blueNet2LastChangeNumberOfSocketGroups OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last socket group number change according to operating time sysUpTime." ::= { blueNet2SocketGroupInfo 4 } blueNet2LastChangeSocketGroupSettings OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last setting change of any socket group connected to BlueNet2 PDU according to operating time sysUpTime. This timestamp will be affected by SNMP settings only!" ::= { blueNet2SocketGroupInfo 5 } blueNet2LastChangeSocketGroups OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last socket group change according to operating time sysUpTime." ::= { blueNet2SocketGroupInfo 6 } blueNet2SocketGroupsAccumulatedStatus OBJECT-TYPE SYNTAX BlueNet2EntityBits MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field of all current socket group states." ::= { blueNet2SocketGroupInfo 7 } blueNet2SocketGroupsInUse OBJECT-TYPE SYNTAX Unsigned32 (1..128) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of socket groups in use." ::= { blueNet2SocketGroupInfo 8 } blueNet2MaxSocketGroups OBJECT-TYPE SYNTAX Unsigned32 (1..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of entries in blueNet2SocketGroupTable." ::= { blueNet2SocketGroupInfo 9 } -- ----------------------------------------------------------------------------- blueNet2SocketGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2SocketGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Headline of socket group table." ::= { blueNet2SocketGroups 2 } blueNet2SocketGroupEntry OBJECT-TYPE SYNTAX BlueNet2SocketGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of socket group table." INDEX { blueNet2SocketGroupIndex } ::= { blueNet2SocketGroupTable 1 } BlueNet2SocketGroupEntry ::= SEQUENCE { blueNet2SocketGroupIndex Unsigned32, blueNet2SocketGroupRowStatus RowStatus, blueNet2SocketGroupGuid OCTET STRING, blueNet2SocketGroupName DisplayString, blueNet2SocketGroupFriendlyName DisplayString, blueNet2SocketGroupDescription DisplayString, blueNet2SocketGroupStatus INTEGER, blueNet2SocketGroupMode BlueNet2SocketModes, blueNet2SocketGroupIdentify BlueNet2SocketModes, blueNet2SocketGroupEntPhysicalIndex Unsigned32, blueNet2SocketGroupAccumulatedStatus BlueNet2EntityBits, blueNet2SocketGroupMembers BlueNet2SocketMembers } blueNet2SocketGroupIndex OBJECT-TYPE SYNTAX Unsigned32 (1..128) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of socket group available on BlueNet2 PDU." ::= { blueNet2SocketGroupEntry 1 } blueNet2SocketGroupRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Activate/create/destroy/disable a socket group entry." ::= { blueNet2SocketGroupEntry 2 } blueNet2SocketGroupGuid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "GUID of socket group on BlueNet2 PDU." ::= { blueNet2SocketGroupEntry 3 } blueNet2SocketGroupName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the socket group connected to BlueNet2 PDU." ::= { blueNet2SocketGroupEntry 4 } blueNet2SocketGroupFriendlyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "User friendlyname of the socket group connected to BlueNet2 PDU." ::= { blueNet2SocketGroupEntry 5 } blueNet2SocketGroupDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "Description of the socket group connected to BlueNet2 PDU." ::= { blueNet2SocketGroupEntry 6 } blueNet2SocketGroupStatus OBJECT-TYPE SYNTAX BlueNet2EntityStates MAX-ACCESS read-only STATUS current DESCRIPTION "Status of socket group." ::= { blueNet2SocketGroupEntry 7 } blueNet2SocketGroupMode OBJECT-TYPE SYNTAX BlueNet2SocketModes MAX-ACCESS read-write STATUS current DESCRIPTION "Mode of all the sockets of a socket group connected to BlueNet2 PDU." ::= { blueNet2SocketGroupEntry 8 } blueNet2SocketGroupIdentify OBJECT-TYPE SYNTAX BlueNet2SocketModes MAX-ACCESS read-write STATUS current DESCRIPTION "Mode of all the socket leds of a socket group connected to BlueNet2 PDU." ::= { blueNet2SocketGroupEntry 9 } blueNet2SocketGroupEntPhysicalIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Corresponding entPhysicalIndex of this socketgroup. 0 if none exists." ::= { blueNet2SocketGroupEntry 10 } blueNet2SocketGroupAccumulatedStatus OBJECT-TYPE SYNTAX BlueNet2EntityBits MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field of all current socket group members states." ::= { blueNet2SocketGroupEntry 11 } blueNet2SocketGroupMembers OBJECT-TYPE SYNTAX BlueNet2SocketMembers MAX-ACCESS read-write STATUS current DESCRIPTION "The set of sockets which are members of this socket group." ::= { blueNet2SocketGroupEntry 12 } --- ============================================================================= -- blueNet2Variables: global BlueNet2 PDU Variables -- blueNet2VariableInfo OBJECT IDENTIFIER ::= { blueNet2Variables 1 } blueNet2OverallVariableStatus OBJECT-TYPE SYNTAX BlueNet2ComponentStates MAX-ACCESS read-only STATUS current DESCRIPTION "Overall status of all variables." ::= { blueNet2VariableInfo 1 } blueNet2NumberOfVariables OBJECT-TYPE SYNTAX Unsigned32 (1..128) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of variables available." ::= { blueNet2VariableInfo 2 } blueNet2LastChangeOverallVariableStatus OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last status change of any variables connected to BlueNet2 PDU according to operating time sysUpTime." ::= { blueNet2VariableInfo 3 } blueNet2LastChangeNumberOfVariables OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last variables number change according to operating time sysUpTime." ::= { blueNet2VariableInfo 4 } blueNet2LastChangeVariableSettings OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last setting change of any variables connected to BlueNet2 PDU according to operating time sysUpTime. This timestamp will be affected by SNMP settings only!" ::= { blueNet2VariableInfo 5 } blueNet2LastChangeVariableStatus OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last variable status change according to operating time sysUpTime." ::= { blueNet2VariableInfo 6 } blueNet2VariablesAccumulatedStatus OBJECT-TYPE SYNTAX BlueNet2EntityBits MAX-ACCESS read-only STATUS current DESCRIPTION "A bit field of all current variable states." ::= { blueNet2VariableInfo 7 } blueNet2NumberOfChangesVariableScaling OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of changes in variable scaling due to overrun or reset. Variables are given most accurate, each using its own scaling. But some variables are accumulated and may overrun time by time. In case of overrun or manually reset of a variable its scaling will be changed and this counter gets incremented." ::= { blueNet2VariableInfo 8 } blueNet2LastChangeVariableScaling OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last variable scaling change according to operating time sysUpTime." ::= { blueNet2VariableInfo 9 } blueNet2LastChangeVariableReset OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of last manually reset of a variable according to operating time sysUpTime." ::= { blueNet2VariableInfo 10 } -- ----------------------------------------------------------------------------- blueNet2VariableTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2VariableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Headline of variable table." ::= { blueNet2Variables 2 } blueNet2VariableEntry OBJECT-TYPE SYNTAX BlueNet2VariableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of variable table." INDEX { blueNet2VariableId } ::= { blueNet2VariableTable 1 } BlueNet2VariableEntry ::= SEQUENCE { blueNet2VariableId OCTET STRING, blueNet2VariableGuid OCTET STRING, blueNet2VariableName DisplayString, blueNet2VariableFriendlyName DisplayString, blueNet2VariableDescription DisplayString, blueNet2VariableType BlueNet2DataSourceTypes, blueNet2VariableStatus BlueNet2EntityStates, blueNet2VariableAlarm DisplayString, blueNet2VariableScaling Integer32, blueNet2VariableUnit BlueNet2DataSourceUnits, blueNet2VariableSetPoint INTEGER, blueNet2VariableMode INTEGER, blueNet2VariableEntPhysicalIndex Unsigned32 } blueNet2VariableId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "GUID of variable." ::= { blueNet2VariableEntry 1 } blueNet2VariableGuid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "GUID of variable." ::= { blueNet2VariableEntry 2 } blueNet2VariableName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the variable connected to BlueNet2 PDU." ::= { blueNet2VariableEntry 3 } blueNet2VariableFriendlyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "User friendlyname of the variable connected to BlueNet2 PDU." ::= { blueNet2VariableEntry 4 } blueNet2VariableDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Description of the variable connected to BlueNet2 PDU." ::= { blueNet2VariableEntry 5 } blueNet2VariableType OBJECT-TYPE SYNTAX BlueNet2DataSourceTypes MAX-ACCESS read-only STATUS current DESCRIPTION "Type of variable." ::= { blueNet2VariableEntry 6 } blueNet2VariableStatus OBJECT-TYPE SYNTAX BlueNet2EntityStates MAX-ACCESS read-only STATUS current DESCRIPTION "General status of variable connected to BlueNet2 PDU." ::= { blueNet2VariableEntry 7 } blueNet2VariableAlarm OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm text of variable connected to BlueNet2 PDU." ::= { blueNet2VariableEntry 8 } blueNet2VariableScaling OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Scaling of variable as 10^x." ::= { blueNet2VariableEntry 9 } blueNet2VariableUnit OBJECT-TYPE SYNTAX BlueNet2DataSourceUnits MAX-ACCESS read-only STATUS current DESCRIPTION "Unit of variable." ::= { blueNet2VariableEntry 10 } blueNet2VariableSetPoint OBJECT-TYPE SYNTAX INTEGER { notAvailable (1), available (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Set point supported for this variable." ::= { blueNet2VariableEntry 11 } blueNet2VariableMode OBJECT-TYPE SYNTAX INTEGER { resettable (0), reset (1), noReset (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset mode of a variable. Variables in mode reset(1) can by reset by writing reset(1). No other values than reset(1) can be written." ::= { blueNet2VariableEntry 12 } blueNet2VariableEntPhysicalIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Corresponding entPhysicalIndex of this variable. 0 if none exists." ::= { blueNet2VariableEntry 13 } -- ----------------------------------------------------------------------------- blueNet2VariableSetPointTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2VariableSetPointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Headline of variable set point table." ::= { blueNet2Variables 3 } blueNet2VariableSetPointEntry OBJECT-TYPE SYNTAX BlueNet2VariableSetPointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of variable set point table." INDEX { blueNet2VariableSetPointGuid } ::= { blueNet2VariableSetPointTable 1 } BlueNet2VariableSetPointEntry ::= SEQUENCE { blueNet2VariableSetPointGuid OCTET STRING, blueNet2VariableSetPointType BITS, blueNet2VariableSetPointMinValue Integer32, blueNet2VariableSetPointMaxValue Integer32, blueNet2VariableSetPointLowerAlarm Integer32, blueNet2VariableSetPointLowerWarning Integer32, blueNet2VariableSetPointUpperWarning Integer32, blueNet2VariableSetPointUpperAlarm Integer32, blueNet2VariableSetPointHysteresis Unsigned32, blueNet2VariableSetPointRcmACUpperAlarmThreshold DisplayString, blueNet2VariableSetPointRcmACUpperAlarmGradient DisplayString, blueNet2VariableSetPointRcmACUpperWarningThreshold DisplayString, blueNet2VariableSetPointRcmACUpperWarningGradient DisplayString } blueNet2VariableSetPointGuid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "GUID of set point." ::= { blueNet2VariableSetPointEntry 1 } blueNet2VariableSetPointType OBJECT-TYPE SYNTAX BITS { highAlarm (0), lowAlarm (1), highWarning (2), lowWarning (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of setpoint." ::= { blueNet2VariableSetPointEntry 2 } blueNet2VariableSetPointMinValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum value of setpoint." ::= { blueNet2VariableSetPointEntry 3 } blueNet2VariableSetPointMaxValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum value of setpoint." ::= { blueNet2VariableSetPointEntry 4 } blueNet2VariableSetPointLowerAlarm OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Lower threshold of variable." ::= { blueNet2VariableSetPointEntry 5 } blueNet2VariableSetPointLowerWarning OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Lower Warning of variable." ::= { blueNet2VariableSetPointEntry 6 } blueNet2VariableSetPointUpperWarning OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Upper warning of variable." ::= { blueNet2VariableSetPointEntry 7 } blueNet2VariableSetPointUpperAlarm OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Upper threshold of variable." ::= { blueNet2VariableSetPointEntry 8 } blueNet2VariableSetPointHysteresis OBJECT-TYPE SYNTAX Unsigned32 (0..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Hysteresis of variable." ::= { blueNet2VariableSetPointEntry 9 } blueNet2VariableSetPointRcmACUpperAlarmThreshold OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Upper Alarm threshold of RCM AC." ::= { blueNet2VariableSetPointEntry 10 } blueNet2VariableSetPointRcmACUpperAlarmGradient OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Upper Alarm gradient of RCM AC." ::= { blueNet2VariableSetPointEntry 11 } blueNet2VariableSetPointRcmACUpperWarningThreshold OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Upper Warning threshold of RCM AC." ::= { blueNet2VariableSetPointEntry 12 } blueNet2VariableSetPointRcmACUpperWarningGradient OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Upper Warning gradient of RCM AC." ::= { blueNet2VariableSetPointEntry 13 } -- ----------------------------------------------------------------------------- blueNet2VariableDataTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2VariableDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Headline of variable data table. This table contains a subset of frequently changing variables as in blueNet2VariableDataTable, like measured values and status." ::= { blueNet2Variables 4 } blueNet2VariableDataEntry OBJECT-TYPE SYNTAX BlueNet2VariableDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of variable date table." INDEX { blueNet2VariableGuid } ::= { blueNet2VariableDataTable 1 } BlueNet2VariableDataEntry ::= SEQUENCE { blueNet2VariableDataId OCTET STRING, blueNet2VariableDataGuid OCTET STRING, blueNet2VariableDataType BlueNet2DataSourceTypes, blueNet2VariableDataStatus BlueNet2EntityStates, blueNet2VariableDataValue Integer32, blueNet2VariableDataDateTime DateAndTime } blueNet2VariableDataId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "GUID of variable." ::= { blueNet2VariableDataEntry 1 } blueNet2VariableDataGuid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "GUID of variable." ::= { blueNet2VariableDataEntry 2 } blueNet2VariableDataType OBJECT-TYPE SYNTAX BlueNet2DataSourceTypes MAX-ACCESS read-only STATUS current DESCRIPTION "Type of variable." ::= { blueNet2VariableDataEntry 3 } blueNet2VariableDataStatus OBJECT-TYPE SYNTAX BlueNet2EntityStates MAX-ACCESS read-only STATUS current DESCRIPTION "Status of variable." ::= { blueNet2VariableDataEntry 4 } blueNet2VariableDataValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of variable." ::= { blueNet2VariableDataEntry 5 } blueNet2VariableDataDateTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of variable." ::= { blueNet2VariableDataEntry 6 } -- ----------------------------------------------------------------------------- blueNet2VariableDataByTypeTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2VariableDataByTypeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Headline of variable data by type table. This table contains a subset of frequently changing variables as in blueNet2VariableDataByTypeTable, like measured values and status. This table is ordered by type of measurement source." ::= { blueNet2Variables 5 } blueNet2VariableDataByTypeEntry OBJECT-TYPE SYNTAX BlueNet2VariableDataByTypeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of variable data by type table." INDEX { blueNet2VariableDataByType,blueNet2VariableDataByTypeGuid } ::= { blueNet2VariableDataByTypeTable 1 } BlueNet2VariableDataByTypeEntry ::= SEQUENCE { blueNet2VariableDataByType BlueNet2DataSourceTypes, blueNet2VariableDataByTypeGuid OCTET STRING, blueNet2VariableDataByTypeType BlueNet2DataSourceTypes, blueNet2VariableDataByTypeStatus BlueNet2EntityStates, blueNet2VariableDataByTypeValue Integer32, blueNet2VariableDataByTypeDateTime DateAndTime } blueNet2VariableDataByType OBJECT-TYPE SYNTAX BlueNet2DataSourceTypes MAX-ACCESS not-accessible STATUS current DESCRIPTION "Type of variable." ::= { blueNet2VariableDataByTypeEntry 1 } blueNet2VariableDataByTypeGuid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "GUID of variable." ::= { blueNet2VariableDataByTypeEntry 2 } blueNet2VariableDataByTypeType OBJECT-TYPE SYNTAX BlueNet2DataSourceTypes MAX-ACCESS read-only STATUS current DESCRIPTION "Type of variable." ::= { blueNet2VariableDataByTypeEntry 3 } blueNet2VariableDataByTypeStatus OBJECT-TYPE SYNTAX BlueNet2EntityStates MAX-ACCESS read-only STATUS current DESCRIPTION "Status of variable." ::= { blueNet2VariableDataByTypeEntry 4 } blueNet2VariableDataByTypeValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of variable." ::= { blueNet2VariableDataByTypeEntry 5 } blueNet2VariableDataByTypeDateTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of variable." ::= { blueNet2VariableDataByTypeEntry 6 } -- ----------------------------------------------------------------------------- blueNet2VariableDataByStateTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2VariableDataByStateEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Headline of variable data by state table. This table contains a subset of frequently changing variables as in blueNet2VariableDataByStateTable, like measured values and status. This table is ordered by the state of variable. This table is updated periodically in a 15 seconds intervall! Therefore a variable state may temporarily not reflect the current state!" ::= { blueNet2Variables 6 } blueNet2VariableDataByStateEntry OBJECT-TYPE SYNTAX BlueNet2VariableDataByStateEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Entries of variable data by state table." INDEX { blueNet2VariableDataByState,blueNet2VariableDataByStateGuid } ::= { blueNet2VariableDataByStateTable 1 } BlueNet2VariableDataByStateEntry ::= SEQUENCE { blueNet2VariableDataByState BlueNet2EntityStates, blueNet2VariableDataByStateGuid OCTET STRING, blueNet2VariableDataByStateType BlueNet2DataSourceTypes, blueNet2VariableDataByStateStatus BlueNet2EntityStates, blueNet2VariableDataByStateValue Integer32, blueNet2VariableDataByStateDateTime DateAndTime } blueNet2VariableDataByState OBJECT-TYPE SYNTAX BlueNet2EntityStates MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Status of variable." ::= { blueNet2VariableDataByStateEntry 1 } blueNet2VariableDataByStateGuid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "GUID of variable." ::= { blueNet2VariableDataByStateEntry 2 } blueNet2VariableDataByStateType OBJECT-TYPE SYNTAX BlueNet2DataSourceTypes MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Type of variable." ::= { blueNet2VariableDataByStateEntry 3 } blueNet2VariableDataByStateStatus OBJECT-TYPE SYNTAX BlueNet2EntityStates MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Status of variable." ::= { blueNet2VariableDataByStateEntry 4 } blueNet2VariableDataByStateValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Value of variable." ::= { blueNet2VariableDataByStateEntry 5 } blueNet2VariableDataByStateDateTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Timestamp of variable." ::= { blueNet2VariableDataByStateEntry 6 } -- ----------------------------------------------------------------------------- blueNet2VariableDataBySourceTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2VariableDataBySourceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Headline of variable data by state table. This table contains a subset of frequently changing variables as in blueNet2VariableDataBySourceTable, like measured values and status. This table is ordered by the source of variable." ::= { blueNet2Variables 7 } blueNet2VariableDataBySourceEntry OBJECT-TYPE SYNTAX BlueNet2VariableDataBySourceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of variable data by source table." INDEX { blueNet2VariableDataBySource,blueNet2VariableDataBySourceGuid } ::= { blueNet2VariableDataBySourceTable 1 } BlueNet2VariableDataBySourceEntry ::= SEQUENCE { blueNet2VariableDataBySource BlueNet2EntitySources, blueNet2VariableDataBySourceGuid OCTET STRING, blueNet2VariableDataBySourceType BlueNet2DataSourceTypes, blueNet2VariableDataBySourceStatus BlueNet2EntityStates, blueNet2VariableDataBySourceValue Integer32, blueNet2VariableDataBySourceDateTime DateAndTime } blueNet2VariableDataBySource OBJECT-TYPE SYNTAX BlueNet2EntitySources MAX-ACCESS not-accessible STATUS current DESCRIPTION "Source of variable." ::= { blueNet2VariableDataBySourceEntry 1 } blueNet2VariableDataBySourceGuid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "GUID of variable." ::= { blueNet2VariableDataBySourceEntry 2 } blueNet2VariableDataBySourceType OBJECT-TYPE SYNTAX BlueNet2DataSourceTypes MAX-ACCESS read-only STATUS current DESCRIPTION "Type of variable." ::= { blueNet2VariableDataBySourceEntry 3 } blueNet2VariableDataBySourceStatus OBJECT-TYPE SYNTAX BlueNet2EntityStates MAX-ACCESS read-only STATUS current DESCRIPTION "Status of variable." ::= { blueNet2VariableDataBySourceEntry 4 } blueNet2VariableDataBySourceValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of variable." ::= { blueNet2VariableDataBySourceEntry 5 } blueNet2VariableDataBySourceDateTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of variable." ::= { blueNet2VariableDataBySourceEntry 6 } --- ============================================================================= -- blueNet2MPStates: global BlueNet2 Overview of Measurement Point States -- blueNet2MPTable OBJECT-TYPE SYNTAX SEQUENCE OF BlueNet2MPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Headline of MP (Measurement Point) table." ::= { blueNet2MPStates 1 } blueNet2MPEntry OBJECT-TYPE SYNTAX BlueNet2MPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of Measurement Point table." INDEX { blueNet2MPID } ::= { blueNet2MPTable 1 } BlueNet2MPEntry ::= SEQUENCE { blueNet2MPID OCTET STRING, blueNet2MPGuid OCTET STRING, blueNet2MPName DisplayString, blueNet2MPFriendlyName DisplayString, blueNet2MPState BlueNet2EntityStates, blueNet2MPTimeStamp DateAndTime } blueNet2MPID OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "GUID of a Measurement Point." ::= { blueNet2MPEntry 1 } blueNet2MPGuid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "GUID of a Measurement Point." ::= { blueNet2MPEntry 2 } blueNet2MPName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of a Measurement Point." ::= { blueNet2MPEntry 3 } blueNet2MPFriendlyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "User friendlyname of a Measurement Point." ::= { blueNet2MPEntry 4 } blueNet2MPState OBJECT-TYPE SYNTAX BlueNet2EntityStates MAX-ACCESS read-only STATUS current DESCRIPTION "Status of a Measurement Point." ::= { blueNet2MPEntry 5 } blueNet2MPTimeStamp OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of the last change of a Measurement Point." ::= { blueNet2MPEntry 6 } -- ***************************************************************************** -- Traps -- blueNet2TrapPrefix OBJECT IDENTIFIER ::= { blueNet2Traps 0 } blueNet2PduStatusOkTrap NOTIFICATION-TYPE OBJECTS { blueNet2DeviceGuid, blueNet2DeviceStatus, blueNet2DeviceAlarm } STATUS current DESCRIPTION "PDU status ok." -- -- #CATEGORY "Status Events." -- #TYPE "PDU status ok." -- #SUMMARY "Guid %x device status is %i: %s." -- #ARGUMENTS {0,1,2} -- #SEVERITY INFORMATIONAL -- #STATE OPERATIONAL -- ::= { blueNet2TrapPrefix 1 } blueNet2PduStatusWarningTrap NOTIFICATION-TYPE OBJECTS { blueNet2DeviceGuid, blueNet2DeviceStatus, blueNet2DeviceAlarm } STATUS current DESCRIPTION "PDU status warning." -- -- #CATEGORY "Status Events." -- #TYPE "PDU status warning." -- #SUMMARY "Guid %x device status is %i: %s." -- #ARGUMENTS {0,1,2} -- #SEVERITY MINOR -- #STATE OPERATIONAL -- ::= { blueNet2TrapPrefix 2 } blueNet2PduStatusAlarmTrap NOTIFICATION-TYPE OBJECTS { blueNet2DeviceGuid, blueNet2DeviceStatus, blueNet2DeviceAlarm } STATUS current DESCRIPTION "PDU status alarm." -- -- #CATEGORY "Status Events." -- #TYPE "PDU status alarm." -- #SUMMARY "Guid %x device status is %i: %s." -- #ARGUMENTS {0,1,2} -- #SEVERITY MAJOR -- #STATE OPERATIONAL -- ::= { blueNet2TrapPrefix 3 } blueNet2SensorStatusOkTrap NOTIFICATION-TYPE OBJECTS { blueNet2SensorGuid, blueNet2SensorStatus, blueNet2SensorAlarm } STATUS current DESCRIPTION "Sensor status change." -- -- #CATEGORY "Status Events." -- #TYPE "Sensor status ok." -- #SUMMARY "Guid %x sensor status is %i: %s." -- #ARGUMENTS {0,1,2} -- #SEVERITY INFORMATIONAL -- #STATE OPERATIONAL -- ::= { blueNet2TrapPrefix 4 } blueNet2SensorStatusWarningTrap NOTIFICATION-TYPE OBJECTS { blueNet2SensorGuid, blueNet2SensorStatus, blueNet2SensorAlarm } STATUS current DESCRIPTION "Sensor status change." -- -- #CATEGORY "Status Events." -- #TYPE "Sensor status warning." -- #SUMMARY "Guid %x sensor status is %i: %s." -- #ARGUMENTS {0,1,2} -- #SEVERITY MINOR -- #STATE OPERATIONAL -- ::= { blueNet2TrapPrefix 5 } blueNet2SensorStatusAlarmTrap NOTIFICATION-TYPE OBJECTS { blueNet2SensorGuid, blueNet2SensorStatus, blueNet2SensorAlarm } STATUS current DESCRIPTION "Sensor status change." -- -- #CATEGORY "Status Events." -- #TYPE "Sensor status alarm." -- #SUMMARY "Guid %x sensor status is %i: %s." -- #ARGUMENTS {0,1,2} -- #SEVERITY MAJOR -- #STATE OPERATIONAL -- ::= { blueNet2TrapPrefix 6 } blueNet2VariableStatusOkTrap NOTIFICATION-TYPE OBJECTS { blueNet2VariableDataGuid, blueNet2VariableDataStatus, blueNet2VariableDataValue, blueNet2VariableAlarm } STATUS current DESCRIPTION "Variable status is ok." -- -- #CATEGORY "Threshold Events." -- #TYPE "Variable status is ok." -- #SUMMARY "Guid %x variable value %i is ok (%i), %s." -- #ARGUMENTS {0,1,2,3} -- #SEVERITY INFORMATIONAL -- #STATE OPERATIONAL -- ::= { blueNet2TrapPrefix 7 } blueNet2VariableLowerWarningTrap NOTIFICATION-TYPE OBJECTS { blueNet2VariableDataGuid, blueNet2VariableDataStatus, blueNet2VariableDataValue, blueNet2VariableSetPointLowerAlarm, blueNet2VariableAlarm } STATUS current DESCRIPTION "Variable status lower warning." -- -- #CATEGORY "Threshold Events." -- #TYPE "Variable status lower warning." -- #SUMMARY "Guid %x variable value %i deceeds %i (%i), %s." -- #ARGUMENTS {0,2,1,3,4} -- #SEVERITY MINOR -- #STATE OPERATIONAL -- ::= { blueNet2TrapPrefix 8 } blueNet2VariableUpperWarningTrap NOTIFICATION-TYPE OBJECTS { blueNet2VariableDataGuid, blueNet2VariableDataStatus, blueNet2VariableDataValue, blueNet2VariableSetPointUpperWarning, blueNet2VariableAlarm } STATUS current DESCRIPTION "Variable status upper warning." -- -- #CATEGORY "Threshold Events." -- #TYPE "Variable status upper warning." -- #SUMMARY "Guid %x variable value %i exceeds %i (%i), %s." -- #ARGUMENTS {0,2,1,3,4} -- #SEVERITY MINOR -- #STATE OPERATIONAL -- ::= { blueNet2TrapPrefix 9 } blueNet2VariableLowerAlarmTrap NOTIFICATION-TYPE OBJECTS { blueNet2VariableDataGuid, blueNet2VariableDataStatus, blueNet2VariableDataValue, blueNet2VariableSetPointLowerAlarm, blueNet2VariableAlarm } STATUS current DESCRIPTION "Variable status lower alarm." -- -- #CATEGORY "Threshold Events." -- #TYPE "Variable status lower alarm." -- #SUMMARY "Guid %x variable value %i deceeds %i (%i), %s." -- #ARGUMENTS {0,2,1,3,4} -- #SEVERITY MAJOR -- #STATE OPERATIONAL -- ::= { blueNet2TrapPrefix 10 } blueNet2VariableUpperAlarmTrap NOTIFICATION-TYPE OBJECTS { blueNet2VariableDataGuid, blueNet2VariableDataStatus, blueNet2VariableDataValue, blueNet2VariableSetPointUpperAlarm, blueNet2VariableAlarm } STATUS current DESCRIPTION "Variable status upper alarm." -- -- #CATEGORY "Threshold Events." -- #TYPE "Variable status upper alarm." -- #SUMMARY "Guid %x variable value %i exceeds %i (%i), %s." -- #ARGUMENTS {0,2,1,3,4} -- #SEVERITY MAJOR -- #STATE OPERATIONAL -- ::= { blueNet2TrapPrefix 11 } blueNet2RCMSelftestResultTrap NOTIFICATION-TYPE OBJECTS { blueNet2RcmSelftestResultStr } STATUS current DESCRIPTION "RCM Selftest result." -- -- #CATEGORY "Status Events." -- #TYPE "RCM Selftest result." -- #SUMMARY "RCM Selftest result: %s." -- #ARGUMENTS {0} -- #SEVERITY INFORMATIONAL -- #STATE OPERATIONAL -- ::= { blueNet2TrapPrefix 12 } blueNet2ReconfigAgentTrap NOTIFICATION-TYPE OBJECTS { sysObjectID } STATUS current DESCRIPTION "Agent reconfiguration." -- -- #CATEGORY "Status Events." -- #TYPE "Agent status." -- #SUMMARY "Agent type: %s, Status: configuration has changed." -- #ARGUMENTS {0} -- #SEVERITY INFORMATIONAL -- #TIMEINDEX 6 -- #STATE OPERATIONAL -- ::= { blueNet2TrapPrefix 98 } blueNet2ShutdownAgentTrap NOTIFICATION-TYPE OBJECTS { sysObjectID } STATUS current DESCRIPTION "Agent shutdown." -- -- #CATEGORY "Status Events." -- #TYPE "Agent status." -- #SUMMARY "Agent type: %s, Status: shutdown." -- #ARGUMENTS {0} -- #SEVERITY SEVERE -- #TIMEINDEX 6 -- #STATE NONOPERATIONAL -- ::= { blueNet2TrapPrefix 99 } -- ***************************************************************************** -- Compliance Statements -- blueNet2Compliances OBJECT IDENTIFIER ::= { blueNet2Conformance 1 } blueNet2Groups OBJECT IDENTIFIER ::= { blueNet2Conformance 2 } blueNet2Compliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The core compliance statement for all BlueNet2 PDU implementations." MODULE MANDATORY-GROUPS { blueNet2NotificationGroup, blueNet2TrapGroup, blueNet2IdentificationGroup, blueNet2InformationGroup, blueNet2ConfigurationGroup, blueNet2RcmGroup, blueNet2SpdGroup, blueNet2SmtpGroup, blueNet2SnmpGroup, blueNet2NtpGroup, blueNet2ModbusGroup, blueNet2DeviceGroup, blueNet2SensorGroup, blueNet2CircuitGroup, blueNet2SocketGroup, blueNet2VariableGroup, blueNet2MPGroup } GROUP blueNet2NotificationGroup DESCRIPTION "SNMP notification handling." GROUP blueNet2TrapGroup DESCRIPTION "SNMP trap handling." GROUP blueNet2IdentificationGroup DESCRIPTION "base identification handling." GROUP blueNet2InformationGroup DESCRIPTION "base information handling." GROUP blueNet2ConfigurationGroup DESCRIPTION "base configuration handling." GROUP blueNet2NtpGroup DESCRIPTION "Simple Network Time Protocol (NTP) handling." GROUP blueNet2SyslogGroup DESCRIPTION "System log handling." GROUP blueNet2SmtpGroup DESCRIPTION "Simple Mail Transfer Protocol (SMTP) handling." GROUP blueNet2SnmpGroup DESCRIPTION "Simple Network Management Protocol (SNMP) handling." GROUP blueNet2ModbusGroup DESCRIPTION "Modbus ASCII/RTU/TCP handling." GROUP blueNet2DeviceGroup DESCRIPTION "BlueNet2 PDU device handling." GROUP blueNet2SensorGroup DESCRIPTION "BlueNet2 PDU sensor handling." GROUP blueNet2CircuitGroup DESCRIPTION "BlueNet2 PDU circuit handling." GROUP blueNet2PhaseGroup DESCRIPTION "BlueNet2 PDU phase handling." GROUP blueNet2FuseGroup DESCRIPTION "BlueNet2 PDU fuse handling." GROUP blueNet2SocketGroup DESCRIPTION "BlueNet2 PDU socket handling." GROUP blueNet2SocketGroupGroup DESCRIPTION "BlueNet2 PDU socket group handling." GROUP blueNet2VariableGroup DESCRIPTION "BlueNet2 PDU variable handling." GROUP blueNet2MPGroup DESCRIPTION "BlueNet2 Measurement Point handling." ::= { blueNet2Compliances 1 } -- ***************************************************************************** -- Conformance Groups -- blueNet2TrapGroup OBJECT-GROUP OBJECTS { blueNet2DeviceGuid, blueNet2DeviceStatus, blueNet2DeviceAlarm, blueNet2SensorGuid, blueNet2SensorStatus, blueNet2SensorAlarm, blueNet2VariableDataGuid, blueNet2VariableDataStatus, blueNet2VariableDataValue, blueNet2VariableSetPointLowerAlarm, blueNet2VariableSetPointLowerWarning, blueNet2VariableSetPointUpperWarning, blueNet2VariableSetPointUpperAlarm, blueNet2VariableAlarm } STATUS current DESCRIPTION "Conformance group for all objects contained in BlueNet2 PDU traps." ::= { blueNet2Groups 1 } blueNet2NotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { blueNet2PduStatusOkNotification, blueNet2PduStatusWarningNotification, blueNet2PduStatusAlarmNotification, blueNet2SensorStatusOkNotification, blueNet2SensorStatusWarningNotification, blueNet2SensorStatusAlarmNotification, blueNet2VariableStatusOkNotification, blueNet2VariableLowerWarningNotification, blueNet2VariableUpperWarningNotification, blueNet2VariableLowerAlarmNotification, blueNet2VariableUpperAlarmNotification, blueNet2ReconfigAgentNotification, blueNet2ShutdownAgentNotification, blueNet2PduStatusOkTrap, blueNet2PduStatusWarningTrap, blueNet2PduStatusAlarmTrap, blueNet2SensorStatusOkTrap, blueNet2SensorStatusWarningTrap, blueNet2SensorStatusAlarmTrap, blueNet2VariableStatusOkTrap, blueNet2VariableLowerWarningTrap, blueNet2VariableUpperWarningTrap, blueNet2VariableLowerAlarmTrap, blueNet2VariableUpperAlarmTrap, blueNet2RCMSelftestResultTrap, blueNet2ReconfigAgentTrap, blueNet2ShutdownAgentTrap } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU notifications." ::= { blueNet2Groups 2 } blueNet2IdentificationGroup OBJECT-GROUP OBJECTS { blueNet2IdProductVendor, blueNet2IdProductURI, blueNet2IdProductName, blueNet2IdProductPartNr, blueNet2IdProductSNr, blueNet2IdProductDate, blueNet2IdProductFacility, blueNet2IdProductCaps, blueNet2IdProductFwV, blueNet2IdProductHwV, blueNet2IdProductSwV, blueNet2IdProductOsV, blueNet2IdProductArch, blueNet2IdProductMAC } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU base identfication." ::= { blueNet2Groups 3 } blueNet2InformationGroup OBJECT-GROUP OBJECTS { blueNet2InfoUpTime, blueNet2InfoOverallStatus, blueNet2InfoNumberOfChanges, blueNet2InfoLastChange, blueNet2InfoAccumulatedStatus, blueNet2InfoLoadAverage, blueNet2InfoMessageStatus, blueNet2InfoMessageTime, blueNet2InfoMessageText, blueNet2InfoMessageNumberOfOks, blueNet2InfoMessageNumberOfWarnings, blueNet2InfoMessageNumberOfErrors } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU base information." ::= { blueNet2Groups 4 } blueNet2ConfigurationGroup OBJECT-GROUP OBJECTS { blueNet2Alias, blueNet2Language, blueNet2FtpAccess, blueNet2FtpPort, blueNet2HttpAccess, blueNet2HttpPort, blueNet2HttpsPort, blueNet2SftpAccess, blueNet2SftpPort, blueNet2SshAccess, blueNet2SshPort, blueNet2TelnetAccess, blueNet2TelnetPort } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU base configuration." ::= { blueNet2Groups 5 } blueNet2SnmpGroup OBJECT-GROUP OBJECTS { blueNet2SnmpVersions, blueNet2MaxTrapReceivers, blueNet2TrapReceiverRowStatus, blueNet2TrapReceiverProtocol, blueNet2TrapReceiverAddress, blueNet2TrapReceiverFriendlyName, blueNet2TrapReceiverDescription, blueNet2TrapReceiverCommunity, blueNet2TrapReceiverUsername } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU SNMP configuration." ::= { blueNet2Groups 6 } blueNet2ModbusGroup OBJECT-GROUP OBJECTS { blueNet2ModbusVersions, blueNet2ModbusService, blueNet2ModbusTcpPort, blueNet2ModbusSerialMode, blueNet2MaxModbusTcpMasters, blueNet2ModbusTcpRowStatus, blueNet2ModbusTcpAccess, blueNet2ModbusTcpMaster, blueNet2ModbusTcpFriendlyName, blueNet2ModbusTcpDescription } STATUS current DESCRIPTION "Conformance group for blueNet2 PDU modbus configuration." ::= { blueNet2Groups 7 } blueNet2NtpGroup OBJECT-GROUP OBJECTS { blueNet2DateTime, blueNet2NtpService, blueNet2NtpPort, blueNet2NtpTimeZone, blueNet2MaxNtpServers, blueNet2NtpServerRowStatus, blueNet2NtpServerAddress, blueNet2NtpServerFriendlyName, blueNet2NtpServerDescription } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU NTP configuration." ::= { blueNet2Groups 8 } blueNet2SmtpGroup OBJECT-GROUP OBJECTS { blueNet2SmtpService, blueNet2SmtpPort, blueNet2SmtpServer, blueNet2SmtpAuth, blueNet2SmtpUsername, blueNet2SmtpPassword, blueNet2SmtpFrom, blueNet2SmtpReply, blueNet2MaxSmtpReceivers, blueNet2SmtpReceiverRowStatus, blueNet2SmtpReceiverAddress, blueNet2SmtpReceiverFriendlyName, blueNet2SmtpReceiverDescription } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU SMTP configuration." ::= { blueNet2Groups 9 } blueNet2SyslogGroup OBJECT-GROUP OBJECTS { blueNet2SyslogService, blueNet2SyslogFacility, blueNet2MaxSyslogServers, blueNet2SyslogServerRowStatus, blueNet2SyslogServerAddress, blueNet2SyslogServerPort, blueNet2SyslogServerFriendlyName, blueNet2SyslogServerDescription, blueNet2SyslogServerProtocol } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU syslog operations." ::= { blueNet2Groups 10 } blueNet2DeviceGroup OBJECT-GROUP OBJECTS { blueNet2OverallDeviceStatus, blueNet2NumberOfDevices, blueNet2LastChangeOverallDeviceStatus, blueNet2LastChangeNumberOfDevices, blueNet2LastChangeDeviceSettings, blueNet2LastChangeDevices, blueNet2DevicesAccumulatedStatus, blueNet2DeviceGuid, blueNet2DeviceName, blueNet2DeviceFriendlyName, blueNet2DeviceDescription, blueNet2DeviceType, blueNet2DeviceStatus, blueNet2DeviceAlarm, blueNet2DeviceLastChange, blueNet2DeviceEntPhysicalIndex, blueNet2DevicePartNr, blueNet2DeviceSNr, blueNet2DeviceFwV, blueNet2DeviceHwV, blueNet2DeviceSwV, blueNet2DeviceOsV, blueNet2DeviceMAC, blueNet2DeviceNumberOfSensors, blueNet2DeviceNumberOfCircuits, blueNet2DeviceNumberOfPhases, blueNet2DeviceNumberOfFuses, blueNet2DeviceNumberOfSockets, blueNet2DeviceNumberOfRCMs, blueNet2DeviceNumberOfVars, blueNet2DeviceLocation, blueNet2DeviceProductDate, blueNet2DeviceModbusAddr } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU device information." ::= { blueNet2Groups 11 } blueNet2SensorGroup OBJECT-GROUP OBJECTS { blueNet2OverallSensorStatus, blueNet2NumberOfSensors, blueNet2LastChangeOverallSensorStatus, blueNet2LastChangeNumberOfSensors, blueNet2LastChangeSensorSettings, blueNet2LastChangeSensors, blueNet2SensorsAccumulatedStatus, blueNet2SensorGuid, blueNet2SensorName, blueNet2SensorFriendlyName, blueNet2SensorDescription, blueNet2SensorType, blueNet2SensorStatus, blueNet2SensorAlarm, blueNet2SensorLastChange, blueNet2SensorEntPhysicalIndex, blueNet2SensorNumberOfVars, blueNet2SensorHwV, blueNet2SensorFwV, blueNet2SensorSNr, blueNet2SensorVariableGuid, blueNet2SensorVariableName, blueNet2SensorVariableFriendlyName, blueNet2SensorVariableDescription, blueNet2SensorVariableGPIOMode, blueNet2SensorVariableGPIOSwitch, blueNet2SensorVariableGPIOState } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU sensor information." ::= { blueNet2Groups 12 } blueNet2CircuitGroup OBJECT-GROUP OBJECTS { blueNet2OverallCircuitStatus, blueNet2NumberOfCircuits, blueNet2LastChangeOverallCircuitStatus, blueNet2LastChangeNumberOfCircuits, blueNet2LastChangeCircuitSettings, blueNet2LastChangeCircuits, blueNet2CircuitGuid, blueNet2CircuitName, blueNet2CircuitFriendlyName, blueNet2CircuitDescription, blueNet2CircuitType, blueNet2CircuitStatus, blueNet2CircuitNumberOfPhases } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU circuit information." ::= { blueNet2Groups 13 } blueNet2PhaseGroup OBJECT-GROUP OBJECTS { blueNet2PhaseGuid, blueNet2PhaseName, blueNet2PhaseFriendlyName, blueNet2PhaseDescription, blueNet2PhaseStatus, blueNet2PhaseNumberOfFuses } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU phase information." ::= { blueNet2Groups 14 } blueNet2FuseGroup OBJECT-GROUP OBJECTS { blueNet2FuseGuid, blueNet2FuseName, blueNet2FuseFriendlyName, blueNet2FuseDescription, blueNet2FuseType, blueNet2FuseStatus, blueNet2FuseNumberOfSockets } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU fuse information." ::= { blueNet2Groups 15 } blueNet2SocketGroup OBJECT-GROUP OBJECTS { blueNet2SocketGuid, blueNet2SocketName, blueNet2SocketFriendlyName, blueNet2SocketDescription, blueNet2SocketType, blueNet2SocketStatus, blueNet2SocketMode, blueNet2SocketIdentify, blueNet2SocketMemberIndex } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU socket information." ::= { blueNet2Groups 16 } blueNet2RcmGroup OBJECT-GROUP OBJECTS { blueNet2RcmGuid, blueNet2RcmName, blueNet2RcmFriendlyName, blueNet2RcmDescription, blueNet2RcmType, blueNet2RcmStatus } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU RCM information." ::= { blueNet2Groups 17 } blueNet2SocketGroupGroup OBJECT-GROUP OBJECTS { blueNet2OverallSocketGroupStatus, blueNet2NumberOfSocketGroups, blueNet2LastChangeOverallSocketGroupStatus, blueNet2LastChangeNumberOfSocketGroups, blueNet2LastChangeSocketGroupSettings, blueNet2LastChangeSocketGroups, blueNet2SocketGroupsAccumulatedStatus, blueNet2SocketGroupsInUse, blueNet2MaxSocketGroups, blueNet2SocketGroupRowStatus, blueNet2SocketGroupGuid, blueNet2SocketGroupName, blueNet2SocketGroupFriendlyName, blueNet2SocketGroupDescription, blueNet2SocketGroupStatus, blueNet2SocketGroupMode, blueNet2SocketGroupIdentify, blueNet2SocketGroupEntPhysicalIndex, blueNet2SocketGroupAccumulatedStatus, blueNet2SocketGroupMembers } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU socket groups." ::= { blueNet2Groups 18 } blueNet2VariableGroup OBJECT-GROUP OBJECTS { blueNet2OverallVariableStatus, blueNet2NumberOfVariables, blueNet2LastChangeOverallVariableStatus, blueNet2LastChangeNumberOfVariables, blueNet2LastChangeVariableSettings, blueNet2LastChangeVariableStatus, blueNet2VariablesAccumulatedStatus, blueNet2NumberOfChangesVariableScaling, blueNet2LastChangeVariableScaling, blueNet2LastChangeVariableReset, blueNet2VariableGuid, blueNet2VariableName, blueNet2VariableFriendlyName, blueNet2VariableDescription, blueNet2VariableType, blueNet2VariableStatus, blueNet2VariableAlarm, blueNet2VariableScaling, blueNet2VariableUnit, blueNet2VariableSetPoint, blueNet2VariableMode, blueNet2VariableEntPhysicalIndex, blueNet2VariableSetPointType, blueNet2VariableSetPointMinValue, blueNet2VariableSetPointMaxValue, blueNet2VariableSetPointLowerAlarm, blueNet2VariableSetPointLowerWarning, blueNet2VariableSetPointUpperWarning, blueNet2VariableSetPointUpperAlarm, blueNet2VariableSetPointHysteresis, blueNet2VariableSetPointRcmACUpperAlarmThreshold, blueNet2VariableSetPointRcmACUpperAlarmGradient, blueNet2VariableSetPointRcmACUpperWarningThreshold, blueNet2VariableSetPointRcmACUpperWarningGradient, blueNet2VariableDataType, blueNet2VariableDataStatus, blueNet2VariableDataValue, blueNet2VariableDataDateTime, blueNet2VariableDataByTypeType, blueNet2VariableDataByTypeStatus, blueNet2VariableDataByTypeValue, blueNet2VariableDataByTypeDateTime, blueNet2VariableDataByStateType, blueNet2VariableDataByStateStatus, blueNet2VariableDataByStateValue, blueNet2VariableDataByStateDateTime, blueNet2VariableDataBySourceType, blueNet2VariableDataBySourceStatus, blueNet2VariableDataBySourceValue, blueNet2VariableDataBySourceDateTime } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU variable information." ::= { blueNet2Groups 19 } blueNet2MPGroup OBJECT-GROUP OBJECTS { blueNet2MPGuid, blueNet2MPName, blueNet2MPFriendlyName, blueNet2MPState, blueNet2MPTimeStamp } STATUS current DESCRIPTION "Conformance group for BlueNet2 Measurement Point information." ::= { blueNet2Groups 20 } blueNet2SpdGroup OBJECT-GROUP OBJECTS { blueNet2SpdGuid, blueNet2SpdName, blueNet2SpdFriendlyName, blueNet2SpdDescription, blueNet2SpdType, blueNet2SpdStatus } STATUS current DESCRIPTION "Conformance group for BlueNet2 PDU SPD information." ::= { blueNet2Groups 21 } -- ***************************************************************************** -- Capabilities -- -- please refer to BACHMANN-BLUENET2-CAPABILITY-MIB definitions -- -- ***************************************************************************** END