------------------------------------------------------------------------------- -- -- FILE ATTO Bridge Private SNMP MIB -- -- DESCRIPTION Bridge SNMP Management Information Base -- -- THIS PROGRAM AND THE INFORMATION CONTAINED HEREIN IS THE PROPERTY OF -- ATTO TECHNOLOGY, INC. AND SHALL NOT BE REPRODUCED, COPIED, OR USED IN -- WHOLE OR IN PART OTHER THAN AS PROVIDED FOR IN THE LICENSE AGREEMENT -- PURSUANT TO WHICH IT WAS FURNISHED. -- -- COPYRIGHT (c) ATTO TECHNOLOGY, INC. 1996 - 2006 -- ALL RIGHTS RESERVED. -- ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- -- Standard version ------------------------------------------------------------------------------- ATTOBRIDGE-MIB DEFINITIONS ::= BEGIN IMPORTS IpAddress, experimental, enterprises FROM RFC1155-SMI ifIndex, DisplayString FROM RFC1213-MIB NOTIFICATION-TYPE FROM SNMPv2-SMI; -- -- According to ftp://ftp.isi.edu/in-notes/iana/assignments/enterprise-numbers, -- ATTO's enterprise number is registered as being 4547. -- attotech OBJECT IDENTIFIER ::= { enterprises 4547 } products OBJECT IDENTIFIER ::= { attotech 1 } bridge MODULE-IDENTITY LAST-UPDATED "200509200000Z" -- 20 Sep, 2005 ORGANIZATION "ATTO Technology, Inc." CONTACT-INFO "ATTO" DESCRIPTION "Bridge Custom MIB" ::= { products 2 } bridgeConfig OBJECT IDENTIFIER ::= { bridge 1 } bridgeStatus OBJECT IDENTIFIER ::= { bridge 2 } bridgeTrapInfo OBJECT IDENTIFIER ::= { bridge 3 } --bridgeTraps OBJECT IDENTIFIER ::= { bridge 4 } ------------------------------------------------------------------------------- -- OBJECT DEFINITIONS ------------------------------------------------------------------------------- trapsEnabled OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether traps are enabled or disabled." ::= { bridgeConfig 1 } snmpUpdatesEnabled OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether SNMP updates are enabled or disabled." ::= { bridgeConfig 2 } snmpExtendedEnabled OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether extended SNMP is enabled or disabled." ::= { bridgeConfig 3 } ------------------------------------------------------------------------------- -- OBJECT TABLE DEFINITIONS ------------------------------------------------------------------------------- -- -- -- Temperature Sensor Table -- tempSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF TempSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The temperature sensor table stores information about the bridge temperature sensor." ::= { bridgeStatus 1 } tempSensorEntry OBJECT-TYPE SYNTAX TempSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The temperature sensor table stores information about the bridge temperature sensor." INDEX { tempSensorIndex } ::= { tempSensorTable 1 } TempSensorEntry ::= SEQUENCE { tempSensorIndex INTEGER, tempSensorStatus INTEGER, temperature INTEGER } tempSensorIndex OBJECT-TYPE SYNTAX INTEGER (1..3) ACCESS read-only STATUS mandatory DESCRIPTION "Used to index the sensor in the temperature sensor table." ::= { tempSensorEntry 1 } tempSensorStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), warning(2), critical(3), unknown(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of the sensor (normal, warning or critical)." ::= { tempSensorEntry 2 } temperature OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current temperature of the sensor." ::= { tempSensorEntry 3 } -- -- -- Voltage Sensor Table -- voltageSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF VoltageSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The voltage sensor table stores information about the bridge voltage sensor." ::= { bridgeStatus 2 } voltageSensorEntry OBJECT-TYPE SYNTAX VoltageSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The voltage sensor table stores information about the bridge voltage sensor." INDEX { voltageSensorIndex } ::= { voltageSensorTable 1 } VoltageSensorEntry ::= SEQUENCE { voltageSensorIndex INTEGER, voltageSensorStatus INTEGER, voltage INTEGER } voltageSensorIndex OBJECT-TYPE SYNTAX INTEGER (1..3) ACCESS read-only STATUS mandatory DESCRIPTION "Used to index the sensor in the voltage sensor table." ::= { voltageSensorEntry 1 } voltageSensorStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), warning(2), critical(3), unknown(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status of the sensor (normal, warning or critical)." ::= { voltageSensorEntry 2 } voltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current voltage of the sensor." ::= { voltageSensorEntry 3 } -- -- -- Device Table -- deviceCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of devices present." ::= { bridgeStatus 4 } deviceCacheTable OBJECT-TYPE SYNTAX SEQUENCE OF DeviceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The device table stores information about the devices attached to the bridge." ::= { bridgeStatus 5 } deviceEntry OBJECT-TYPE SYNTAX DeviceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The device table stores information about the devices attached to the bridge." INDEX { deviceCacheIndex } ::= { deviceCacheTable 1 } DeviceEntry ::= SEQUENCE { deviceCacheIndex INTEGER, deviceSource DisplayString, deviceDestination DisplayString, deviceType DisplayString, deviceVendor DisplayString, deviceProduct DisplayString, deviceRevision DisplayString, deviceState INTEGER } deviceCacheIndex OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-only STATUS mandatory DESCRIPTION "Used to index the device table." ::= { deviceEntry 1 } deviceSource OBJECT-TYPE SYNTAX DisplayString (SIZE (0..79)) ACCESS read-only STATUS mandatory DESCRIPTION "A string representing the source interface, meaning the interface exposed to the host." ::= { deviceEntry 2 } deviceDestination OBJECT-TYPE SYNTAX DisplayString (SIZE (0..79)) ACCESS read-only STATUS mandatory DESCRIPTION "A string representing the destination interface, meaning the interface of the target device." ::= { deviceEntry 3 } deviceType OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "Device type (i.e. DISK, TAPE, etc.) of attached device." ::= { deviceEntry 4 } deviceVendor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Vendor name of attached device, from inquiry data." ::= { deviceEntry 5 } deviceProduct OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "Product name of attached device, from inquiry data." ::= { deviceEntry 6 } deviceRevision OBJECT-TYPE SYNTAX DisplayString (SIZE (0..4)) ACCESS read-only STATUS mandatory DESCRIPTION "Revision of attached device, from inquiry data." ::= { deviceEntry 7 } deviceState OBJECT-TYPE SYNTAX INTEGER { offline(0), online(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the device (online, offline, or unknown)." ::= { deviceEntry 8 } -- -- -- Error Table -- errorCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of errors that have occured since last bridge power-on or reset." ::= { bridgeStatus 6 } errorsSinceUpdate OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of errors that have occured since last MIB scan, which is approximately every 15sec." ::= { bridgeStatus 7 } errorTable OBJECT-TYPE SYNTAX SEQUENCE OF ErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Device Error table stores information about errors that have occurred with the devices attached to the bridge." ::= { bridgeStatus 8 } errorEntry OBJECT-TYPE SYNTAX ErrorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Device Error table stores information about errors that have occurred with the devices attached to the bridge." INDEX { errorIndex } ::= { errorTable 1 } ErrorEntry ::= SEQUENCE { errorIndex INTEGER, errorDateStamp DisplayString, errorTimeStamp DisplayString, errorInitiator DisplayString, errorSource DisplayString, errorOpCode INTEGER, errorSenseKey INTEGER, errorASC INTEGER, errorASCQ INTEGER, errorLogSense OCTET STRING } errorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Used to index the error device table." ::= { errorEntry 1 } errorDateStamp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..11)) ACCESS read-only STATUS mandatory DESCRIPTION "Date at which the error occurred." ::= { errorEntry 2 } errorTimeStamp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..9)) ACCESS read-only STATUS mandatory DESCRIPTION "Time at which the error occurred." ::= { errorEntry 3 } errorInitiator OBJECT-TYPE SYNTAX DisplayString (SIZE (0..79)) ACCESS read-only STATUS mandatory DESCRIPTION "A string representing the initiator which issued the failed command." ::= { errorEntry 4 } errorSource OBJECT-TYPE SYNTAX DisplayString (SIZE (0..79)) ACCESS read-only STATUS mandatory DESCRIPTION "A string representing the source interface, meaning the interface exposed to the host, which is associated with the error." ::= { errorEntry 5 } errorOpCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "OpCode of the command which failed." ::= { errorEntry 6 } errorSenseKey OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Sense Key returned as a result of the failed command." ::= { errorEntry 7 } errorASC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ASC returned as a result of the failed command." ::= { errorEntry 8 } errorASCQ OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ASCQ returned as a result of the failed command." ::= { errorEntry 9 } errorLogSense OBJECT-TYPE SYNTAX OCTET STRING (SIZE(64)) ACCESS read-only STATUS mandatory DESCRIPTION "Log Sense returned as a result of the failed command." ::= { errorEntry 10 } ------------------------------------------------------------------------------- -- TRAP DEFINITIONS ------------------------------------------------------------------------------- trapMaxClients OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of SNMP trap recipients supported by the unit." ::= { bridgeTrapInfo 1 } -- -- Currently not supported -- --trapClientCount OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION "The current number of rows in the trap table." -- ::= { bridgeTrapInfo 2 } -- -- Trap table definition -- trapClientTable OBJECT-TYPE SYNTAX SEQUENCE OF TrapClientEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing a row for each IP address/port number that traps will be sent to." ::= { bridgeTrapInfo 3 } trapClientEntry OBJECT-TYPE SYNTAX TrapClientEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Ip/Port pair for a specific client." INDEX { trapClientIndex } ::= { trapClientTable 1 } TrapClientEntry ::= SEQUENCE { trapClientIndex INTEGER, trapClientIpAddress IpAddress, trapClientPort INTEGER, trapClientFilter INTEGER, trapClientRowState INTEGER } trapClientIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Used to index a trap client in the trapClientTable." ::= { trapClientEntry 1 } trapClientIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address of a client registered for traps in dotted notation." ::= { trapClientEntry 2 } trapClientPort OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The UDP port to send traps for this host. Normally this would be the standard trap port (162). This object is an index and must be specified to create a row in this table." ::= { trapClientEntry 3 } trapClientFilter OBJECT-TYPE SYNTAX INTEGER { none (1), critical (2), warning (3), informational (4), all (5) } ACCESS read-only STATUS mandatory DESCRIPTION "This value defines the trap severity filter for this trap host. The unit will send traps to this host that have a severity level less than or equal to this value. The default value of this object is 'warning'." ::= { trapClientEntry 4 } trapClientRowState OBJECT-TYPE SYNTAX INTEGER { rowDestroy(1), -- Remove row from table rowInactive(2), -- Row exists, but Traps disabled rowActive(3) -- Row exists and is enabled for -- sending traps } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the state of the row. rowDestroy READ : Can never happen WRITE : Remove this row from the table. rowInactive READ : Indicates that this row does not exist, but that traps are not enabled to be sent to the target. WRITE : If the row does not exist, and the agent allows writes to the trap table, then a new row is created. The values of the optional columns will be set to default values. Traps are not enabled to be sent to the target. If the row already existed, then traps are disabled from being sent to the target. rowActive READ : Indicates that this row exists, and that traps are enabled to be sent to the target. WRITE : If the row does not exist, and the agent allows writes to the trap table, then a new row is created. The values of the optional columns will be set to default traps. If the row already exists then traps are enabled to be sent to the target. A value of rowActive or rowInactive must be specified to create a row in the table." ::= { trapClientEntry 5 } -- -- Bridge specific traps -- bridgeTempStatusChanged TRAP-TYPE ENTERPRISE attotech VARIABLES { tempSensorIndex, tempSensorStatus, temperature } DESCRIPTION "The bridgeTempStatusChanged trap supports notification of temperature status changes in the bridge. The following information is returned: tempSensorIndex - the sensor of concern tempSensorStatus - the current status of the sensor (normal, warning, critical) temperature - current temperature of the sensor Recommended severity level (for filtering): warning" ::= 1 bridgeVoltageStatusChanged TRAP-TYPE ENTERPRISE attotech VARIABLES { voltageSensorIndex, voltageSensorStatus, voltage } DESCRIPTION "The bridgeVoltageStatusChanged trap supports notification of temperature status changes in the bridge. The following information is returned: voltageSensorIndex - the sensor of concern voltageSensorStatus - the current status of the sensor (normal, warning, critical) voltage - current temperature of the sensor Recommended severity level (for filtering): warning" ::= 2 bridgeDeviceTransition TRAP-TYPE ENTERPRISE attotech VARIABLES { deviceCacheIndex, deviceSource, deviceState } DESCRIPTION "The bridgeDeviceTransition trap supports notification of device online/offline status changes in the bridge. The following information is returned: deviceCacheIndex - the device of concern deviceSource - the description of the source device deviceState - the current state of the device Recommended severity level (for filtering): informational" ::= 4 bridgeDeviceError TRAP-TYPE ENTERPRISE attotech VARIABLES { errorSource, errorOpCode, errorSenseKey, errorASC, errorASCQ, errorsSinceUpdate } DESCRIPTION "The bridgeDeviceTransition trap supports notification of device online/offline status changes in the bridge. The following information is returned: errorSource - the description of the source device errorOpCode - the offending command errorSenseKey - the sense key returned by the device errorASC - the ASC returned by the device errorASCQ - the ASCQ returned by the device errorsSinceUpdate - the number of errors in the past 15sec Recommended severity level (for filtering): informational" ::= 5 END -------------------------------------------------------------------------------