-- SiteBoss 450 MIB -- v 4.35 July 2 2013 -- Copyright (c) 2013 by Asentria Corporation. All rights reserved. SITEBOSS-450-STD-MIB DEFINITIONS ::= BEGIN IMPORTS DisplayString FROM SNMPv2-TC IpAddress, TimeTicks, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE FROM SNMPv2-SMI asentria FROM ASENTRIA-ROOT-MIB; --*************************************************************************************** --MODULE IDENTITY --*************************************************************************************** s450 MODULE-IDENTITY LAST-UPDATED "201307020435Z" ORGANIZATION "Asentria Corporation" CONTACT-INFO "Phone: 206-344-8800 Fax: 206-344-2116 Email: support@asentria.com" DESCRIPTION "MIB module for managing Asentria SiteBoss 450" REVISION "201307020435Z" DESCRIPTION "-v4.35 -Added snmpPoll objects (OMX-394). -Applicable since unit version 2.09.560." REVISION "201305280434Z" DESCRIPTION "-v4.34 -Fixed incorrect SYNTAX for sysCharMask (OMX-328). -Added evGlobal branch (OMX-228). -Applicable since unit version 2.09.500." REVISION "201305100433Z" DESCRIPTION "-v4.33 -Fixed incorrect SYNTAX statements for various objects (OMX-314). -Removed references to No Data events. -Applicable since unit version 2.09.380." REVISION "201304100432Z" DESCRIPTION "-v4.32 -Added non-weekly job scheduling objects (OMX-252). -Applicable since unit version 2.09.310." REVISION "201303150431Z" DESCRIPTION "-v4.31 -Renamed sysLocation branch to sysLoc (OMX-198). -Applicable since unit version 2.09.240." REVISION "201303140430Z" DESCRIPTION "-v4.30 -Added snmpProxy branch (OMX-190). -Applicable since unit version 2.09.280." REVISION "201302060429Z" DESCRIPTION "-v4.29 -Renamed telnet* objects. -Applicable since unit version 2.09.240." REVISION "201301140428Z" DESCRIPTION "-v4.28 -Added evReset branch and associated notification (OMX-83). -Applicable since unit version 2.09.220." REVISION "201211190427Z" DESCRIPTION "-v4.27 -Removed notification capture objects. -Added sysFileTransfer and sysUpdate objects. (BN 4632) -Added ethRouting objects. (BN 4620) -Applicable since unit version 2.09.120." REVISION "201208220426Z" DESCRIPTION "-v4.26 -Added additional AC power monitor items." REVISION "201208020425Z" DESCRIPTION "-v4.25 -Removed non-weekly job schedule objects." REVISION "201207090424Z" DESCRIPTION "-v4.24 -Removed wirelessBand object." REVISION "201207060423Z" DESCRIPTION "-v4.23 -Added camera notification definition. -Updated comment for secUserConnectVia object." REVISION "201206120422Z" DESCRIPTION "-v4.22 -Removed user credentials objects." REVISION "201205020421Z" DESCRIPTION "-v4.21 -Added object for location. -Fixed objects for Generator Exercising Non-Start event." REVISION "201204020420Z" DESCRIPTION "-v4.20 -Revamped battery monitor objects." REVISION "201203150419Z" DESCRIPTION "-v4.19 -Added battery monitor status and config objects. -Added AC power monitor config objects." REVISION "201202280418Z" DESCRIPTION "-v4.18 -Fixed acpmsIndex range. -Added various objects for combined sensor status. -Changed meaning of esPointAliasValueStr for relay/power outputs." REVISION "201202210417Z" DESCRIPTION "-v4.17 -Removed genRunReqAsm object." REVISION "201202200416Z" DESCRIPTION "-v4.16 -Added objects for fuel sensor configuration; removed battery monitor status objects." REVISION "201202140415Z" DESCRIPTION "-v4.15 -Added objects for job scheduling, generator exercising, and battery monitor status." REVISION "201202030904Z" DESCRIPTION "-v4.14 -Added generatorNonStartTrap notification definition." REVISION "201201160902Z" DESCRIPTION "-v4.13 -Jumped to 4.xx Asentria version series. The version 4 series officially may improve compatibility with certain NMS installations by grouping all notifications in a dedicated branch. No functional change from version 1.12." REVISION "201112160900Z" DESCRIPTION "-v1.12 -Added s450FuelSensorVolumeSuddenChangeTrap and s450FuelSensorVolumeSlowChangeTrap notification definitions." REVISION "201112060900Z" DESCRIPTION "-v1.11 -Moved notification definitions to dedicated branch." REVISION "201112050900Z" DESCRIPTION "-v1.10 -Added s450StockScriptTrap notification definition." REVISION "201108080900Z" DESCRIPTION "-v1.09 -Added s450StockOutputTrap notification definition." REVISION "201108010900Z" DESCRIPTION "-v1.08 -Added evMgmtReprocess object. -Added acPowerMonitorStatus branch." REVISION "201107080900Z" DESCRIPTION "-v1.07 -Added wirelessModemStatus branch. -Fixed bug where fuelSensorStatus branch was at the wrong object branch." REVISION "201105180900Z" DESCRIPTION "-v1.06 -Added s450FuelSensorVolumeTrap definition. -Added fuel sensor status objects." REVISION "201104150900Z" DESCRIPTION "-v1.05 -Removed reference to nonexistent data events." REVISION "201101050900Z" DESCRIPTION "-v1.04 -Added espcCCNormalThreshold object." REVISION "201012020900Z" DESCRIPTION "-v1.03 -Added esPointAliasValueStr object to simplify getting the current alias value of a CC input according to its current event state. -Added s450FuelSensorDisconnectTrap definition." REVISION "201011030900Z" DESCRIPTION "-v1.02 -Changed deadband, threshold, and current values for temperature sensors from integer to floating-point type. This means the SNMP object type for the temperature settings (deadbands and thresholds) changed from Integer32 to DisplayString. -Fixed bug where SNMP integer range defined in the MIB for trapIncludedValue was 16-bit instead of 32-bit." REVISION "201008240900Z" DESCRIPTION "-v1.01 -Fixed bug where some stock traps had too few varbinds declared. -Removed useless trap definitions. -Corrected product number in comments for each declared object." REVISION "201005170900Z" DESCRIPTION "-v1.00 -Initial version" ::= { asentria 17 } --1.3.6.1.4.1.3052.17 --*************************************************************************************** --Concise MIB View: Top Level Branches --*************************************************************************************** -- status .1 -- eventSensorStatus .1.1 -- esPointTable .1.1.1 -- dataEventStatus .1.2 -- deStatusTable .1.2.1 -- fuelSensorStatus .1.6 -- fsStatusTable .1.6.1 -- wirelessModemStatus .1.7 -- acPowerMonitorStatus .1.8 -- acpmStatusTable .1.8.1 -- batteryMonitorStatus .1.10 -- bmStatusTable .1.10.1 -- bmJarStatusTable .1.10.2 -- config .2 -- eventSensorBasics .2.1 -- esNumberEventSensors .2.1.1 -- esTable .2.1.2 -- esNewSensors .2.1.3 -- eventSensorPointConfig .2.2 -- esPointConfigTempTable .2.2.1 -- esPointConfigCCTable .2.2.2 -- esPointConfigHumidTable .2.2.3 -- esPointConfigAITable .2.2.5 -- serialPorts .2.3 -- numberPorts .2.3.1 -- portConfigTable .2.3.2 -- network .2.4 -- interface .2.4.1 -- defaultRouter .2.4.2 -- dnsTable .2.4.3 -- hostname .2.4.4 -- hostTable .2.4.5 -- ncpDuplex .2.4.6 -- ncpTimeout .2.4.7 -- snmp .2.4.8 -- ftpPush .2.4.9 -- routing .2.4.11 -- netSecurity .2.4.12 -- rts .2.4.13 -- trap .2.4.14 -- wireless .2.4.16 -- email .2.4.17 -- netAdvanced .2.4.18 -- web .2.4.19 -- time .2.8 -- clock .2.8.1 -- console .2.10 -- unitSecurity .2.11 -- secCore .2.11.1 -- secUserTable .2.11.2 -- secFactory .2.11.3 -- event .2.12 -- evCore .2.12.1 -- evSched1 .2.12.5 -- evSched2 .2.12.6 -- evShskLowTable .2.12.7 -- evShskHighTable .2.12.8 -- evNoSensor .2.12.9 -- fuelSensor .2.12.11 -- fuelSensorGeneralTable .2.12.11.1 -- fuelSensorTankTable .2.12.11.2 -- fuelSensorCustomTankTable .2.12.11.3 -- fuelSensorVolumeTable .2.12.11.4 -- fuelSensorDisconnectTable .2.12.11.5 -- fuelSensorSuddenChangeTable .2.12.11.6 -- fuelSensorSlowChangeTable .2.12.11.7 -- acPowerMonitor .2.12.12 -- batteryMonitor .2.12.14 -- evReset .2.12.16 -- evGlobal .2.12.18 -- action .2.14 -- actionSched .2.14.3 -- actionAsentria .2.14.4 -- actionHostTable .2.14.6 -- actionEmailTable .2.14.7 -- actionParseError .2.14.8 -- sys .2.16 -- sysTime .2.16.1 -- sysPT .2.16.2 -- sysMTU .2.16.3 -- sysAnswerString .2.16.4 -- sysEventFileID .2.16.6 -- sysEscapeCharacter .2.16.7 -- sysTimeStamp .2.16.8 -- sysLog .2.16.9 -- sysCRDB .2.16.10 -- sysCharMask .2.16.11 -- sysPrompt .2.16.12 -- sysBootStatus .2.16.13 -- sysLoc .2.16.14 -- sysFileTransfer .2.16.17 -- sysUpdate .2.16.18 -- auditLog .2.17 -- scripting .2.18 -- scrGlobalEnable .2.18.1 -- scrDTRCtrlPortEnableTable .2.18.2 -- scrTable .2.18.3 -- scrVolatileStringTable .2.18.4 -- scrVolatileIntTable .2.18.5 -- scrNonVolatileStringTable .2.18.6 -- scrNonVolatileIntTable .2.18.7 -- generator .2.19 -- genSet .2.19.1 -- genSetRelay .2.19.1.2 -- genSetCc .2.19.1.3 -- genRun .2.19.2 -- genRunNonstartEvent .2.19.2.7 -- calendar .2.20 -- productIds .3 -- siteName 3.1 -- thisProduct .3.2 -- stockTrapString .3.3 -- trapEventTypeNumber .3.4 -- trapEventTypeName .3.5 -- trapIncludedValue .3.6 -- trapIncludedString .3.7 -- trapTypeString .3.8 -- trapEventClassNumber .3.9 -- trapEventClassName .3.10 -- keyInterface .4.0 --*************************************************************************************** --Complete MIB View: All Objects --*************************************************************************************** -- status .1 -- eventSensorStatus .1.1 -- esPointTable .1.1.1 -- esPointEntry .1.1.1.1 -- esIndexES .1.1.1.1.1 -- esIndexPC .1.1.1.1.2 -- esIndexPoint .1.1.1.1.3 -- esPointName .1.1.1.1.4 -- esPointInEventState .1.1.1.1.5 -- esPointValueInt .1.1.1.1.6 -- esPointValueStr .1.1.1.1.7 -- esPointTimeLastChange .1.1.1.1.8 -- esPointTimetickLastChange .1.1.1.1.9 -- esPointAliasValueStr .1.1.1.1.10 -- dataEventStatus .1.2 -- deStatusTable .1.2.1 -- deStatusEntry .1.2.1.1 -- deStatusIndex .1.2.1.1.1 -- deStatusName .1.2.1.1.2 -- deStatusCounter .1.2.1.1.3 -- deStatusThreshold .1.2.1.1.4 -- fuelSensorStatus .1.6 -- fsStatusTable .1.6.1 -- fsStatusEntry .1.6.1.1 -- fsStatusIndex .1.6.1.1.1 -- fsStatusName .1.6.1.1.2 -- fsStatusDeviceState .1.6.1.1.3 -- fsStatusVolumeValueString .1.6.1.1.4 -- fsStatusVolumePercentLevel .1.6.1.1.7 -- fsStatusVolumeInEventState .1.6.1.1.8 -- fsStatusCombined .1.6.1.1.9 -- wirelessModemStatus .1.7 -- wmsStatus .1.7.1 -- wmsSignal .1.7.2 -- wmsRSSI .1.7.3 -- wmsBER .1.7.4 -- wmsUpdated .1.7.5 -- wmsRegistration .1.7.6 -- wmsLAC .1.7.7 -- wmsCellID .1.7.8 -- wmsIMSI .1.7.9 -- wmsPhnum .1.7.10 -- wmsLocalIP .1.7.11 -- wmsMgfID .1.7.12 -- wmsModelID .1.7.13 -- wmsIMEI .1.7.14 -- wmsRevID .1.7.15 -- wmsNetName .1.7.16 -- wmsGPRSStatus .1.7.17 -- wmsBand .1.7.18 -- wmsChannel .1.7.19 -- wmsCountryCode .1.7.20 -- wmsNetCode .1.7.21 -- wmsPLMNColor .1.7.22 -- wmsBScolor .1.7.23 -- wmsMpRACH .1.7.24 -- wmsMinRxLevel .1.7.25 -- wmsBaseCoeff .1.7.26 -- wmsSIMStatus .1.7.27 -- wmsICCID .1.7.28 -- wmsModemType .1.7.29 -- acPowerMonitorStatus .1.8 -- acpmStatusTable .1.8.1 -- acpmStatusEntry .1.8.1.1 -- acpmsIndex .1.8.1.1.1 -- acpmsName .1.8.1.1.2 -- acpmsAvgVoltageValueStr .1.8.1.1.3 -- acpmsAvgVoltageMinStr .1.8.1.1.4 -- acpmsAvgVoltageMaxStr .1.8.1.1.5 -- acpmsAvgVoltageAvgStr .1.8.1.1.6 -- acpmsAvgVoltageInEventState .1.8.1.1.7 -- acpmsVoltagePhaseAValueStr .1.8.1.1.8 -- acpmsVoltagePhaseBValueStr .1.8.1.1.9 -- acpmsVoltagePhaseCValueStr .1.8.1.1.10 -- acpmsAvgCurrentValueStr .1.8.1.1.11 -- acpmsAvgCurrentMinStr .1.8.1.1.12 -- acpmsAvgCurrentMaxStr .1.8.1.1.13 -- acpmsAvgCurrentAvgStr .1.8.1.1.14 -- acpmsAvgCurrentInEventState .1.8.1.1.15 -- acpmsCurrentPhaseAValueStr .1.8.1.1.16 -- acpmsCurrentPhaseBValueStr .1.8.1.1.17 -- acpmsCurrentPhaseCValueStr .1.8.1.1.18 -- acpmsFreqValueStr .1.8.1.1.19 -- acpmsFreqMinStr .1.8.1.1.20 -- acpmsFreqMaxStr .1.8.1.1.21 -- acpmsFreqAvgStr .1.8.1.1.22 -- acpmsFreqInEventState .1.8.1.1.23 -- acpmsTRPValueStr .1.8.1.1.24 -- acpmsTRPMinStr .1.8.1.1.25 -- acpmsTRPMaxStr .1.8.1.1.26 -- acpmsTRPAvgStr .1.8.1.1.27 -- acpmsTRPInEventState .1.8.1.1.28 -- acpmsRPPhaseAValueStr .1.8.1.1.29 -- acpmsRPPhaseBValueStr .1.8.1.1.30 -- acpmsRPPhaseCValueStr .1.8.1.1.31 -- acpmsCombined .1.8.1.1.32 -- acpmsTPFValueStr .1.8.1.1.33 -- acpmsTPFMinStr .1.8.1.1.34 -- acpmsTPFMaxStr .1.8.1.1.35 -- acpmsTPFAvgStr .1.8.1.1.36 -- acpmsTPFInEventState .1.8.1.1.37 -- acpmsPFPhaseAValueStr .1.8.1.1.38 -- acpmsPFPhaseBValueStr .1.8.1.1.39 -- acpmsPFPhaseCValueStr .1.8.1.1.40 -- acpmsTRcPValueStr .1.8.1.1.41 -- acpmsTRcPMinStr .1.8.1.1.42 -- acpmsTRcPMaxStr .1.8.1.1.43 -- acpmsTRcPAvgStr .1.8.1.1.44 -- acpmsRcPPhaseAValueStr .1.8.1.1.45 -- acpmsRcPPhaseBValueStr .1.8.1.1.46 -- acpmsRcPPhaseCValueStr .1.8.1.1.47 -- acpmsTAPValueStr .1.8.1.1.48 -- acpmsTAPMinStr .1.8.1.1.49 -- acpmsTAPMaxStr .1.8.1.1.50 -- acpmsTAPAvgStr .1.8.1.1.51 -- acpmsAPPhaseAValueStr .1.8.1.1.52 -- acpmsAPPhaseBValueStr .1.8.1.1.53 -- acpmsAPPhaseCValueStr .1.8.1.1.54 -- acpmsTotalEnergyWh .1.8.1.1.55 -- acpmsTotalEnergyVAR .1.8.1.1.56 -- acpmsTotalEnergyVA .1.8.1.1.57 -- batteryMonitorStatus .1.10 -- bmStatusTable .1.10.1 -- bmStatusEntry .1.10.1.1 -- bmsIndex .1.10.1.1.1 -- bmsEnable .1.10.1.1.2 -- bmsName .1.10.1.1.3 -- bmsState .1.10.1.1.4 -- bmsStringState .1.10.1.1.5 -- bmsTempValue .1.10.1.1.6 -- bmsTempValueStr .1.10.1.1.7 -- bmsTempEvent .1.10.1.1.8 -- bmsDiffTempValue .1.10.1.1.9 -- bmsDiffTempValueStr .1.10.1.1.10 -- bmsDiffTempEvent .1.10.1.1.11 -- bmsVoltageValue .1.10.1.1.12 -- bmsVoltageEvent .1.10.1.1.13 -- bmsDiffVoltValue .1.10.1.1.14 -- bmsDiffVoltEvent .1.10.1.1.15 -- bmsCurrentValue .1.10.1.1.16 -- bmsChargingCurrentEvent .1.10.1.1.17 -- bmsDischargingCurrentEvent .1.10.1.1.18 -- bmsChargeLevelValue .1.10.1.1.19 -- bmsChargeLevelEvent .1.10.1.1.20 -- bmsJarHealthValue .1.10.1.1.21 -- bmsJarHealthEvent .1.10.1.1.22 -- bmsCombined .1.10.1.1.23 -- bmJarStatusTable .1.10.2 -- bmJarStatusEntry .1.10.2.1 -- bmjsIndexBM .1.10.2.1.1 -- bmjsIndexJar .1.10.2.1.2 -- bmjsVoltageValue .1.10.2.1.3 -- bmjsTempValue .1.10.2.1.4 -- bmjsAdmittanceValue .1.10.2.1.5 -- bmjsAdmittanceChangeValue .1.10.2.1.6 -- config .2 -- eventSensorBasics .2.1 -- esNumberEventSensors .2.1.1 -- esTable .2.1.2 -- esEntry .2.1.2.1 -- esIndex .2.1.2.1.1 -- esName .2.1.2.1.2 -- esID .2.1.2.1.3 -- esNumberTempSensors .2.1.2.1.4 -- esTempReportingMode .2.1.2.1.5 -- esNumberCCs .2.1.2.1.6 -- esCCReportingMode .2.1.2.1.7 -- esNumberHumidSensors .2.1.2.1.8 -- esHumidReportingMode .2.1.2.1.9 -- esNumberNoiseSensors .2.1.2.1.10 -- esNoiseReportingMode .2.1.2.1.11 -- esNumberAirflowSensors .2.1.2.1.12 -- esAirflowReportingMode .2.1.2.1.13 -- esNumberAnalog .2.1.2.1.14 -- esAnalogReportingMode .2.1.2.1.15 -- esNumberRelayOutputs .2.1.2.1.16 -- esRelayReportingMode .2.1.2.1.17 -- esTempCombinedStatus .2.1.2.1.18 -- esCCCombinedStatusBlock1 .2.1.2.1.19 -- esCCCombinedStatusBlock2 .2.1.2.1.20 -- esCCCombinedStatusBlock3 .2.1.2.1.21 -- esCCCombinedStatusBlock4 .2.1.2.1.22 -- esCCCombinedStatusBlock5 .2.1.2.1.23 -- esCCCombinedStatusBlock6 .2.1.2.1.24 -- esCCCombinedStatusBlock7 .2.1.2.1.25 -- esCCCombinedStatusBlock8 .2.1.2.1.26 -- esHumidCombinedStatus .2.1.2.1.27 -- esAnalogCombinedStatusBlock1 .2.1.2.1.28 -- esAnalogCombinedStatusBlock2 .2.1.2.1.29 -- esAnalogCombinedStatusBlock3 .2.1.2.1.30 -- esAnalogCombinedStatusBlock4 .2.1.2.1.31 -- esAnalogCombinedStatusBlock5 .2.1.2.1.32 -- esAnalogCombinedStatusBlock6 .2.1.2.1.33 -- esOutputCombinedStatusBlock1 .2.1.2.1.34 -- esOutputCombinedStatusBlock2 .2.1.2.1.35 -- esNewSensors .2.1.3 -- eventSensorPointConfig .2.2 -- esPointConfigTempTable .2.2.1 -- esPointConfigTempEntry .2.2.1.1 -- espcTempIndexES .2.2.1.1.1 -- espcTempIndexPoint .2.2.1.1.2 -- espcTempEnable .2.2.1.1.3 -- espcTempScale .2.2.1.1.4 -- espcTempDeadband .2.2.1.1.5 -- espcTempVHighTemp .2.2.1.1.6 -- espcTempVHighActions .2.2.1.1.7 -- espcTempVHighTrapnum .2.2.1.1.8 -- espcTempVHighClass .2.2.1.1.9 -- espcTempHighTemp .2.2.1.1.10 -- espcTempHighActions .2.2.1.1.11 -- espcTempHighTrapnum .2.2.1.1.12 -- espcTempHighClass .2.2.1.1.13 -- espcTempNormalActions .2.2.1.1.14 -- espcTempNormalTrapnum .2.2.1.1.15 -- espcTempNormalClass .2.2.1.1.16 -- espcTempLowTemp .2.2.1.1.17 -- espcTempLowActions .2.2.1.1.18 -- espcTempLowTrapnum .2.2.1.1.19 -- espcTempLowClass .2.2.1.1.20 -- espcTempVLowTemp .2.2.1.1.21 -- espcTempVLowActions .2.2.1.1.22 -- espcTempVLowTrapnum .2.2.1.1.23 -- espcTempVLowClass .2.2.1.1.24 -- esPointConfigCCTable .2.2.2 -- esPointConfigCCEntry .2.2.2.1 -- espcCCIndexES .2.2.2.1.1 -- espcCCIndexPoint .2.2.2.1.2 -- espcCCEnable .2.2.2.1.3 -- espcCCName .2.2.2.1.4 -- espcCCEventState .2.2.2.1.5 -- espcCCThreshold .2.2.2.1.6 -- espcCCEventActions .2.2.2.1.7 -- espcCCEventTrapnum .2.2.2.1.8 -- espcCCEventClass .2.2.2.1.9 -- espcCCNormalActions .2.2.2.1.10 -- espcCCNormalTrapnum .2.2.2.1.11 -- espcCCNormalClass .2.2.2.1.12 -- espcCCAlarmAlias .2.2.2.1.13 -- espcCCNormalAlias .2.2.2.1.14 -- espcCCNormalThreshold .2.2.2.1.15 -- esPointConfigHumidTable .2.2.3 -- esPointConfigHumidEntry .2.2.3.1 -- espcHumidIndexES .2.2.3.1.1 -- espcHumidIndexPoint .2.2.3.1.2 -- espcHumidEnable .2.2.3.1.3 -- espcHumidDeadband .2.2.3.1.4 -- espcHumidVHighHumid .2.2.3.1.5 -- espcHumidVHighActions .2.2.3.1.6 -- espcHumidVHighTrapnum .2.2.3.1.7 -- espcHumidVHighClass .2.2.3.1.8 -- espcHumidHighHumid .2.2.3.1.9 -- espcHumidHighActions .2.2.3.1.10 -- espcHumidHighTrapnum .2.2.3.1.11 -- espcHumidHighClass .2.2.3.1.12 -- espcHumidNormalActions .2.2.3.1.13 -- espcHumidNormalTrapnum .2.2.3.1.14 -- espcHumidNormalClass .2.2.3.1.15 -- espcHumidLowHumid .2.2.3.1.16 -- espcHumidLowActions .2.2.3.1.17 -- espcHumidLowTrapnum .2.2.3.1.18 -- espcHumidLowClass .2.2.3.1.19 -- espcHumidVLowHumid .2.2.3.1.20 -- espcHumidVLowActions .2.2.3.1.21 -- espcHumidVLowTrapnum .2.2.3.1.22 -- espcHumidVLowClass .2.2.3.1.23 -- esPointConfigAITable .2.2.5 -- esPointConfigAIEntry .2.2.5.1 -- espcAIIndexES .2.2.5.1.1 -- espcAIIndexPoint .2.2.5.1.2 -- espcAIEnable .2.2.5.1.3 -- espcAIPolarity .2.2.5.1.4 -- espcAIDeadband .2.2.5.1.5 -- espcAIVhighValue .2.2.5.1.6 -- espcAIVhighActions .2.2.5.1.7 -- espcAIVhighTrapnum .2.2.5.1.8 -- espcAIVhighClass .2.2.5.1.9 -- espcAIHighValue .2.2.5.1.10 -- espcAIHighActions .2.2.5.1.11 -- espcAIHighTrapnum .2.2.5.1.12 -- espcAIHighClass .2.2.5.1.13 -- espcAINormalActions .2.2.5.1.14 -- espcAINormalTrapnum .2.2.5.1.15 -- espcAINormalClass .2.2.5.1.16 -- espcAILowValue .2.2.5.1.17 -- espcAILowActions .2.2.5.1.18 -- espcAILowTrapnum .2.2.5.1.19 -- espcAILowClass .2.2.5.1.20 -- espcAIVlowValue .2.2.5.1.21 -- espcAIVlowActions .2.2.5.1.22 -- espcAIVlowTrapnum .2.2.5.1.23 -- espcAIVlowClass .2.2.5.1.24 -- espcAIConvUnitName .2.2.5.1.25 -- espcAIConvHighValue .2.2.5.1.26 -- espcAIConvHighUnit .2.2.5.1.27 -- espcAIConvHighSign .2.2.5.1.28 -- espcAIConvLowValue .2.2.5.1.29 -- espcAIConvLowUnit .2.2.5.1.30 -- espcAIConvLowSign .2.2.5.1.31 -- serialPorts .2.3 -- numberPorts .2.3.1 -- portConfigTable .2.3.2 -- portConfigEntry .2.3.2.1 -- portConfigIndex .2.3.2.1.1 -- portConfigBaud .2.3.2.1.2 -- portConfigDataFormat .2.3.2.1.3 -- portConfigStripPtOutputLfs .2.3.2.1.4 -- portConfigStripPtInputLfs .2.3.2.1.5 -- portConfigMaskEnable .2.3.2.1.7 -- portConfigDAEnable .2.3.2.1.8 -- portConfigStoreAlarmsDPT .2.3.2.1.9 -- portConfigRecordTimeout .2.3.2.1.10 -- portConfigDataType .2.3.2.1.11 -- portConfigEtxToCRLF .2.3.2.1.12 -- portConfigMLREnable .2.3.2.1.13 -- portConfigMLRStartField1Pos .2.3.2.1.14 -- portConfigMLRStartField1Text .2.3.2.1.15 -- portConfigMLRStartField2Pos .2.3.2.1.16 -- portConfigMLRStartField2Text .2.3.2.1.17 -- portConfigMLRNumLinesBefore .2.3.2.1.18 -- portConfigMLREndDetection .2.3.2.1.19 -- portConfigMLRLineCount .2.3.2.1.20 -- portConfigMLREndField1Pos .2.3.2.1.21 -- portConfigMLREndField1Text .2.3.2.1.22 -- portConfigMLREndField2Pos .2.3.2.1.23 -- portConfigMLREndField2Text .2.3.2.1.24 -- portConfigMLRUseComplexRules .2.3.2.1.25 -- portConfigBufferPT .2.3.2.1.26 -- portConfigId .2.3.2.1.27 -- network .2.4 -- interface .2.4.1 -- ethernet .2.4.1.1 -- ethernet1 .2.4.1.1.1 -- eth1Mode .2.4.1.1.1.1 -- eth1Address .2.4.1.1.1.2 -- eth1SubnetMask .2.4.1.1.1.3 -- eth1Router .2.4.1.1.1.4 -- eth1VLAN .2.4.1.1.1.5 -- eth1VLAN1 .2.4.1.1.1.5.1 -- eth1VLAN1ID .2.4.1.1.1.5.1.1 -- eth1VLAN1Priority .2.4.1.1.1.5.1.2 -- eth1VLAN1Address .2.4.1.1.1.5.1.3 -- eth1VLAN1SubnetMask .2.4.1.1.1.5.1.4 -- eth1VLAN1Router .2.4.1.1.1.5.1.5 -- eth1VLAN2 .2.4.1.1.1.5.2 -- eth1VLAN2ID .2.4.1.1.1.5.2.1 -- eth1VLAN2Priority .2.4.1.1.1.5.2.2 -- eth1VLAN2Address .2.4.1.1.1.5.2.3 -- eth1VLAN2SubnetMask .2.4.1.1.1.5.2.4 -- eth1VLAN2Router .2.4.1.1.1.5.2.5 -- eth1VLAN3 .2.4.1.1.1.5.3 -- eth1VLAN3ID .2.4.1.1.1.5.3.1 -- eth1VLAN3Priority .2.4.1.1.1.5.3.2 -- eth1VLAN3Address .2.4.1.1.1.5.3.3 -- eth1VLAN3SubnetMask .2.4.1.1.1.5.3.4 -- eth1VLAN3Router .2.4.1.1.1.5.3.5 -- eth1VLAN4 .2.4.1.1.1.5.4 -- eth1VLAN4ID .2.4.1.1.1.5.4.1 -- eth1VLAN4Priority .2.4.1.1.1.5.4.2 -- eth1VLAN4Address .2.4.1.1.1.5.4.3 -- eth1VLAN4SubnetMask .2.4.1.1.1.5.4.4 -- eth1VLAN4Router .2.4.1.1.1.5.4.5 -- eth1VLAN5 .2.4.1.1.1.5.5 -- eth1VLAN5ID .2.4.1.1.1.5.5.1 -- eth1VLAN5Priority .2.4.1.1.1.5.5.2 -- eth1VLAN5Address .2.4.1.1.1.5.5.3 -- eth1VLAN5SubnetMask .2.4.1.1.1.5.5.4 -- eth1VLAN5Router .2.4.1.1.1.5.5.5 -- eth1VLAN6 .2.4.1.1.1.5.6 -- eth1VLAN6ID .2.4.1.1.1.5.6.1 -- eth1VLAN6Priority .2.4.1.1.1.5.6.2 -- eth1VLAN6Address .2.4.1.1.1.5.6.3 -- eth1VLAN6SubnetMask .2.4.1.1.1.5.6.4 -- eth1VLAN6Router .2.4.1.1.1.5.6.5 -- eth1MAC .2.4.1.1.1.6 -- ethernet2 .2.4.1.1.2 -- eth2Mode .2.4.1.1.2.1 -- eth2Address .2.4.1.1.2.2 -- eth2SubnetMask .2.4.1.1.2.3 -- eth2Router .2.4.1.1.2.4 -- eth2VLAN .2.4.1.1.2.5 -- eth2VLAN1 .2.4.1.1.2.5.1 -- eth2VLAN1ID .2.4.1.1.2.5.1.1 -- eth2VLAN1Priority .2.4.1.1.2.5.1.2 -- eth2VLAN1Address .2.4.1.1.2.5.1.3 -- eth2VLAN1SubnetMask .2.4.1.1.2.5.1.4 -- eth2VLAN1Router .2.4.1.1.2.5.1.5 -- eth2VLAN2 .2.4.1.1.2.5.2 -- eth2VLAN2ID .2.4.1.1.2.5.2.1 -- eth2VLAN2Priority .2.4.1.1.2.5.2.2 -- eth2VLAN2Address .2.4.1.1.2.5.2.3 -- eth2VLAN2SubnetMask .2.4.1.1.2.5.2.4 -- eth2VLAN2Router .2.4.1.1.2.5.2.5 -- eth2VLAN3 .2.4.1.1.2.5.3 -- eth2VLAN3ID .2.4.1.1.2.5.3.1 -- eth2VLAN3Priority .2.4.1.1.2.5.3.2 -- eth2VLAN3Address .2.4.1.1.2.5.3.3 -- eth2VLAN3SubnetMask .2.4.1.1.2.5.3.4 -- eth2VLAN3Router .2.4.1.1.2.5.3.5 -- eth2VLAN4 .2.4.1.1.2.5.4 -- eth2VLAN4ID .2.4.1.1.2.5.4.1 -- eth2VLAN4Priority .2.4.1.1.2.5.4.2 -- eth2VLAN4Address .2.4.1.1.2.5.4.3 -- eth2VLAN4SubnetMask .2.4.1.1.2.5.4.4 -- eth2VLAN4Router .2.4.1.1.2.5.4.5 -- eth2VLAN5 .2.4.1.1.2.5.5 -- eth2VLAN5ID .2.4.1.1.2.5.5.1 -- eth2VLAN5Priority .2.4.1.1.2.5.5.2 -- eth2VLAN5Address .2.4.1.1.2.5.5.3 -- eth2VLAN5SubnetMask .2.4.1.1.2.5.5.4 -- eth2VLAN5Router .2.4.1.1.2.5.5.5 -- eth2VLAN6 .2.4.1.1.2.5.6 -- eth2VLAN6ID .2.4.1.1.2.5.6.1 -- eth2VLAN6Priority .2.4.1.1.2.5.6.2 -- eth2VLAN6Address .2.4.1.1.2.5.6.3 -- eth2VLAN6SubnetMask .2.4.1.1.2.5.6.4 -- eth2VLAN6Router .2.4.1.1.2.5.6.5 -- eth2MAC .2.4.1.1.2.6 -- defaultRouter .2.4.2 -- dnsTable .2.4.3 -- dnsEntry .2.4.3.1 -- dnsIndex .2.4.3.1.1 -- dnsAddress .2.4.3.1.2 -- hostname .2.4.4 -- hostTable .2.4.5 -- hostEntry .2.4.5.1 -- hostIndex .2.4.5.1.1 -- hostDeclaration .2.4.5.1.2 -- ncpDuplex .2.4.6 -- ncpTimeout .2.4.7 -- snmp .2.4.8 -- snmpAgentEnable .2.4.8.1 -- snmpNotificationTx .2.4.8.7 -- snmpNtfnAttempts .2.4.8.7.1 -- snmpNtfnTimeout .2.4.8.7.2 -- snmpNtfnCycles .2.4.8.7.3 -- snmpNtfnSnooze .2.4.8.7.4 -- snmpProxy .2.4.8.8 -- snmpProxyTable .2.4.8.8.1 -- snmpProxyEntry .2.4.8.8.1.1 -- snmpProxyIndex .2.4.8.8.1.1.1 -- snmpProxyOIDBranch .2.4.8.8.1.1.2 -- snmpProxyIP .2.4.8.8.1.1.3 -- snmpProxyPort .2.4.8.8.1.1.4 -- snmpPoll .2.4.8.9 -- snmpPMode .2.4.8.9.1 -- snmpPRequestTable .2.4.8.9.4 -- snmpPRequestEntry .2.4.8.9.4.1 -- snmpPRequestIndex .2.4.8.9.4.1.1 -- snmpPRequestDescription .2.4.8.9.4.1.2 -- snmpPRequestAgent .2.4.8.9.4.1.3 -- snmpPRequestReadcom .2.4.8.9.4.1.4 -- snmpPRequestOID .2.4.8.9.4.1.5 -- snmpPRequestPeriod .2.4.8.9.4.1.6 -- snmpPRequestResultStatus .2.4.8.9.4.1.10 -- snmpPRequestResultValue .2.4.8.9.4.1.11 -- snmpPRequestResultTime .2.4.8.9.4.1.12 -- snmpPRequestResultType .2.4.8.9.4.1.13 -- ftpPush .2.4.9 -- ftpPushEnable .2.4.9.1 -- ftpPushServer .2.4.9.2 -- ftpPushAccount .2.4.9.5 -- ftpPushDirectory .2.4.9.6 -- ftpPushperiod .2.4.9.7 -- ftpPushPushFileTable .2.4.9.8 -- ftpPushPushFileEntry .2.4.9.8.1 -- ftpPushPushFileIndex .2.4.9.8.1.1 -- ftpPushPushFile .2.4.9.8.1.2 -- ftpPushPushAudit .2.4.9.9 -- ftpPushPushAlarms .2.4.9.10 -- ftpPushRemoteFileTable .2.4.9.11 -- ftpPushRemoteFileEntry .2.4.9.11.1 -- ftpPushRemoteFileIndex .2.4.9.11.1.1 -- ftpPushRemoteFileName .2.4.9.11.1.2 -- ftpPushRemoteAlarmName .2.4.9.12 -- ftpPushPassive .2.4.9.13 -- ftpPushIncludeDate .2.4.9.14 -- ftpPushIncludeTime .2.4.9.15 -- ftpPushIncludeSeq .2.4.9.16 -- routing .2.4.11 -- ethRoutingEnable .2.4.11.2 -- ethRoutingNATEnable .2.4.11.3 -- netSecurity .2.4.12 -- ipRestriction .2.4.12.1 -- ipRestrictionTable .2.4.12.1.1 -- ipRestrictionEntry .2.4.12.1.1.1 -- ipRestrictionIndex .2.4.12.1.1.1.1 -- ipRestrictionEnable .2.4.12.1.1.1.2 -- ipRestrictionMask .2.4.12.1.1.1.3 -- rts .2.4.13 -- rtsFileTable .2.4.13.1 -- rtsFileEntry .2.4.13.1.1 -- rtsFileIndex .2.4.13.1.1.1 -- rtsFileMode .2.4.13.1.1.2 -- rtsFileShowAnswer .2.4.13.1.1.3 -- rtsFileReqXON .2.4.13.1.1.4 -- rtsFileTimeout .2.4.13.1.1.5 -- rtsFileEmptyClose .2.4.13.1.1.6 -- rtsFilePushHost .2.4.13.1.1.7 -- rtsFilePushPort .2.4.13.1.1.8 -- rtsFilePushRetryTimer .2.4.13.1.1.9 -- rtsAlarms .2.4.13.2 -- rtsAlarmsMode .2.4.13.2.1 -- rtsAlarmsShowAnswer .2.4.13.2.2 -- rtsAlarmsReqXON .2.4.13.2.3 -- rtsAlarmsTimeout .2.4.13.2.4 -- rtsAlarmsEmptyClose .2.4.13.2.5 -- rtsAlarmsPushHost .2.4.13.2.6 -- rtsAlarmsPushPort .2.4.13.2.7 -- rtsAlarmsPushRetryTimer .2.4.13.2.8 -- trap .2.4.14 -- trapInclude .2.4.14.1 -- trapIncludeDateTime .2.4.14.1.1 -- trapIncludeSiteName .2.4.14.1.2 -- trapIncludeSensorID .2.4.14.1.3 -- trapIncludeUDName .2.4.14.1.4 -- trapIncludeUDState .2.4.14.1.5 -- trapIncludeSourceAddress .2.4.14.1.6 -- trapAuthFailEnable .2.4.14.2 -- wireless .2.4.16 -- wirelessMode .2.4.16.1 -- wirelessAPN .2.4.16.2 -- wirelessIdleTimeout .2.4.16.3 -- wirelessPIN .2.4.16.5 -- wirelessDRE .2.4.16.9 -- email .2.4.17 -- emailServer .2.4.17.1 -- emailDomain .2.4.17.2 -- emailAuthEnable .2.4.17.3 -- netAdvanced .2.4.18 -- arpFilter .2.4.18.1 -- web .2.4.19 -- webEnable .2.4.19.1 -- webPort .2.4.19.1 -- webTimeout .2.4.19.1 -- time .2.8 -- clock .2.8.1 -- console .2.10 -- consoleDuplex .2.10.1 -- consoleTimeout .2.10.2 -- consoleConfirm .2.10.7 -- unitSecurity .2.11 -- secCore .2.11.1 -- scShowPasswordPrompt .2.11.1.1 -- scConsoleLoginRequired .2.11.1.2 -- scModemLoginRequired .2.11.1.3 -- scTelnetLoginRequired .2.11.1.4 -- scTelnetPTLoginRequired .2.11.1.5 -- scRTSLoginRequired .2.11.1.6 -- scAuthMode .2.11.1.7 -- scRightsGroup .2.11.1.8 -- scSecret .2.11.1.9 -- secUserTable .2.11.2 -- secUserEntry .2.11.2.1 -- secUserIndex .2.11.2.1.1 -- secUserEnable .2.11.2.1.2 -- secUserConnectVia .2.11.2.1.5 -- secUserLoginTo .2.11.2.1.6 -- secUserAccessFile .2.11.2.1.7 -- secUserPTEscapeTo .2.11.2.1.9 -- secUserPPPType .2.11.2.1.10 -- secUserRights .2.11.2.1.11 -- secUserEventsReadAccess .2.11.2.1.13 -- secUserAuditReadAccess .2.11.2.1.14 -- secUserEventsWriteAccess .2.11.2.1.16 -- secUserAuditWriteAccess .2.11.2.1.17 -- secUserExpiration .2.11.2.1.18 -- secUserCallbackNumber1 .2.11.2.1.19 -- secUserCallbackNumber2 .2.11.2.1.20 -- secUserCallbackNumber3 .2.11.2.1.21 -- secUserChallengeTelnetMode .2.11.2.1.22 -- secUserChallengeModemMode .2.11.2.1.23 -- secUserChallengeConsoleMode .2.11.2.1.24 -- secUserChallengeTelnetSendTo .2.11.2.1.25 -- secUserChallengeModemSendTo .2.11.2.1.26 -- secUserChallengeExpiration .2.11.2.1.27 -- secFactory .2.11.3 -- sfEnable .2.11.3.1 -- sfSecret .2.11.3.2 -- event .2.12 -- evCore .2.12.1 -- evClassNameTable .2.12.1.1 -- evClassNameEntry .2.12.1.1.1 -- evClassNameIndex .2.12.1.1.1.1 -- evClassName .2.12.1.1.1.2 -- evReminderInterval .2.12.1.2 -- evLog .2.12.1.3 -- evLogEnable .2.12.1.3.1 -- evLogStoreAlarm .2.12.1.3.2 -- evLogMaxSize .2.12.1.3.3 -- evLogStoreSensor .2.12.1.3.4 -- evLogTimeStampAlarms .2.12.1.3.5 -- evLogPrependName .2.12.1.3.6 -- evMgmt .2.12.1.4 -- evMgmtReprocess .2.12.1.4.3 -- evSched1 .2.12.5 -- evSched1Enable .2.12.5.1 -- evSched1Actions .2.12.5.2 -- evSched1Message .2.12.5.3 -- evSched1TrapNum .2.12.5.4 -- evSched1Class .2.12.5.5 -- evSched1Sunday .2.12.5.6 -- evSched1Monday .2.12.5.7 -- evSched1Tuesday .2.12.5.8 -- evSched1Wednesday .2.12.5.9 -- evSched1Thursday .2.12.5.10 -- evSched1Friday .2.12.5.11 -- evSched1Saturday .2.12.5.12 -- evSched1Exclusions .2.12.5.13 -- evSched2 .2.12.6 -- evSched2Enable .2.12.6.1 -- evSched2Actions .2.12.6.2 -- evSched2Message .2.12.6.3 -- evSched2TrapNum .2.12.6.4 -- evSched2Class .2.12.6.5 -- evSched2Sunday .2.12.6.6 -- evSched2Monday .2.12.6.7 -- evSched2Tuesday .2.12.6.8 -- evSched2Wednesday .2.12.6.9 -- evSched2Thursday .2.12.6.10 -- evSched2Friday .2.12.6.11 -- evSched2Saturday .2.12.6.12 -- evSched2Exclusions .2.12.6.13 -- evShskLowTable .2.12.7 -- evShskLowEntry .2.12.7.1 -- evShskLowIndex .2.12.7.1.1 -- evShskLowEnable .2.12.7.1.2 -- evShskLowActions .2.12.7.1.3 -- evShskLowMessage .2.12.7.1.4 -- evShskLowClass .2.12.7.1.5 -- evShskLowTrapNum .2.12.7.1.6 -- evShskHighTable .2.12.8 -- evShskHighEntry .2.12.8.1 -- evShskHighIndex .2.12.8.1.1 -- evShskHighEnable .2.12.8.1.2 -- evShskHighActions .2.12.8.1.3 -- evShskHighMessage .2.12.8.1.4 -- evShskHighClass .2.12.8.1.5 -- evShskHighTrapNum .2.12.8.1.6 -- evNoSensor .2.12.9 -- evNoSensorTimeout .2.12.9.1 -- evNoSensorActions .2.12.9.2 -- evNoSensorTrapNum .2.12.9.3 -- evNoSensorClass .2.12.9.4 -- fuelSensor .2.12.11 -- fuelSensorGeneralTable .2.12.11.1 -- fsGenEntry .2.12.11.1.1 -- fsGenIndex .2.12.11.1.1.1 -- fsGenName .2.12.11.1.1.2 -- fsGenSensorType .2.12.11.1.1.3 -- fsGenDistanceUnit .2.12.11.1.1.4 -- fsGenRawValueTop .2.12.11.1.1.5 -- fsGenTopOffset .2.12.11.1.1.6 -- fsGenRawValueBottom .2.12.11.1.1.7 -- fsGenBottomOffset .2.12.11.1.1.8 -- fsGenInputES .2.12.11.1.1.9 -- fsGenInputPoint .2.12.11.1.1.10 -- fsGenFilterAveraging .2.12.11.1.1.11 -- fsGenSysrepEnable .2.12.11.1.1.12 -- fsGenSysrepThreshold .2.12.11.1.1.13 -- fsGenSysrepLimit .2.12.11.1.1.14 -- fsGenSysrepPackage .2.12.11.1.1.15 -- fsGenSysrepType .2.12.11.1.1.16 -- fuelSensorTankTable .2.12.11.2 -- fsTankEntry .2.12.11.2.1 -- fsTankIndex .2.12.11.2.1.1 -- fsTankHeight .2.12.11.2.1.2 -- fsTankDimA .2.12.11.2.1.3 -- fsTankDimB .2.12.11.2.1.4 -- fsTankVolume .2.12.11.2.1.5 -- fsTankVolumeUnit .2.12.11.2.1.6 -- fsTankShape .2.12.11.2.1.7 -- fuelSensorCustomTankTable .2.12.11.3 -- fsCustomTankEntry .2.12.11.3.1 -- fsCustomTankIndexFS .2.12.11.3.1.1 -- fsCustomTankIndexDatum .2.12.11.3.1.2 -- fsCustomTankHeight .2.12.11.3.1.3 -- fsCustomTankVolume .2.12.11.3.1.4 -- fuelSensorVolumeTable .2.12.11.4 -- fsVolumeEntry .2.12.11.4.1 -- fsVolumeIndex .2.12.11.4.1.1 -- fsVolumeEnable .2.12.11.4.1.2 -- fsVolumeDeadband .2.12.11.4.1.3 -- fsVolumeVHighValue .2.12.11.4.1.4 -- fsVolumeVHighActions .2.12.11.4.1.5 -- fsVolumeVHighTrapNum .2.12.11.4.1.6 -- fsVolumeVHighClass .2.12.11.4.1.7 -- fsVolumeHighValue .2.12.11.4.1.8 -- fsVolumeHighActions .2.12.11.4.1.9 -- fsVolumeHighTrapNum .2.12.11.4.1.10 -- fsVolumeHighClass .2.12.11.4.1.11 -- fsVolumeNormalActions .2.12.11.4.1.12 -- fsVolumeNormalTrapNum .2.12.11.4.1.13 -- fsVolumeNormalClass .2.12.11.4.1.14 -- fsVolumeLowValue .2.12.11.4.1.15 -- fsVolumeLowActions .2.12.11.4.1.16 -- fsVolumeLowTrapNum .2.12.11.4.1.17 -- fsVolumeLowClass .2.12.11.4.1.18 -- fsVolumeVLowValue .2.12.11.4.1.19 -- fsVolumeVLowActions .2.12.11.4.1.20 -- fsVolumeVLowTrapNum .2.12.11.4.1.21 -- fsVolumeVLowClass .2.12.11.4.1.22 -- fuelSensorDisconnectTable .2.12.11.5 -- fsDiscEntry .2.12.11.5.1 -- fsDiscIndex .2.12.11.5.1.1 -- fsDiscEnable .2.12.11.5.1.2 -- fsDiscHighValue .2.12.11.5.1.3 -- fsDiscLowValue .2.12.11.5.1.4 -- fsDiscActions .2.12.11.5.1.5 -- fsDiscTrapNum .2.12.11.5.1.6 -- fsDiscClass .2.12.11.5.1.7 -- fsDiscNormalActions .2.12.11.5.1.8 -- fsDiscNormalTrapNum .2.12.11.5.1.9 -- fsDiscNormalClass .2.12.11.5.1.10 -- fuelSensorSuddenChangeTable .2.12.11.6 -- fsSuddenChangeEntry .2.12.11.6.1 -- fsSuddenChangeIndex .2.12.11.6.1.1 -- fsSuddenChangeEnable .2.12.11.6.1.2 -- fsSuddenChangeTime .2.12.11.6.1.3 -- fsSuddenChangeAmplitude .2.12.11.6.1.4 -- fsSuddenChangeActions .2.12.11.6.1.5 -- fsSuddenChangeTrapNum .2.12.11.6.1.6 -- fsSuddenChangeClass .2.12.11.6.1.7 -- fuelSensorSlowChangeTable .2.12.11.7 -- fuelSensorSlowChangeEntry .2.12.11.7.1 -- fsSlowChangeIndex .2.12.11.7.1.1 -- fsSlowChangeEnable .2.12.11.7.1.2 -- fsSlowChangeTime .2.12.11.7.1.3 -- fsSlowChangeAmplitude .2.12.11.7.1.4 -- fsSlowChangeActions .2.12.11.7.1.5 -- fsSlowChangeTrapNum .2.12.11.7.1.6 -- fsSlowChangeClass .2.12.11.7.1.7 -- acPowerMonitor .2.12.12 -- acpmGeneralTable .2.12.12.1 -- acpmGenEntry .2.12.12.1.1 -- acpmGenIndex .2.12.12.1.1.1 -- acpmGenDevice .2.12.12.1.1.2 -- acpmGenName .2.12.12.1.1.3 -- acpmGenAddress .2.12.12.1.1.4 -- acpmGenPtRatio .2.12.12.1.1.5 -- acpmGenCtRatio .2.12.12.1.1.6 -- acpmGenPowerType .2.12.12.1.1.7 -- acpmGenSysrepPackage .2.12.12.1.1.8 -- acpmGenSysrepType .2.12.12.1.1.9 -- acpmAvgVoltageTable .2.12.12.2 -- acpmAvgVoltageEntry .2.12.12.2.1 -- acpmAvgVoltageIndex .2.12.12.2.1.1 -- acpmAvgVoltageEnable .2.12.12.2.1.2 -- acpmAvgVoltageDeadband .2.12.12.2.1.3 -- acpmAvgVoltageVHighValue .2.12.12.2.1.4 -- acpmAvgVoltageVHighActions .2.12.12.2.1.5 -- acpmAvgVoltageVHighTrapNum .2.12.12.2.1.6 -- acpmAvgVoltageVHighClass .2.12.12.2.1.7 -- acpmAvgVoltageHighValue .2.12.12.2.1.8 -- acpmAvgVoltageHighActions .2.12.12.2.1.9 -- acpmAvgVoltageHighTrapNum .2.12.12.2.1.10 -- acpmAvgVoltageHighClass .2.12.12.2.1.11 -- acpmAvgVoltageNormalActions .2.12.12.2.1.12 -- acpmAvgVoltageNormalTrapNum .2.12.12.2.1.13 -- acpmAvgVoltageNormalClass .2.12.12.2.1.14 -- acpmAvgVoltageLowValue .2.12.12.2.1.15 -- acpmAvgVoltageLowActions .2.12.12.2.1.16 -- acpmAvgVoltageLowTrapNum .2.12.12.2.1.17 -- acpmAvgVoltageLowClass .2.12.12.2.1.18 -- acpmAvgVoltageVLowValue .2.12.12.2.1.19 -- acpmAvgVoltageVLowActions .2.12.12.2.1.20 -- acpmAvgVoltageVLowTrapNum .2.12.12.2.1.21 -- acpmAvgVoltageVLowClass .2.12.12.2.1.22 -- acpmAvgVoltageSysrepEnable .2.12.12.2.1.23 -- acpmAvgVoltageSysrepThreshold .2.12.12.2.1.24 -- acpmAvgVoltageSysrepLimit .2.12.12.2.1.25 -- acpmAvgCurrentTable .2.12.12.3 -- acpmAvgCurrentEntry .2.12.12.3.1 -- acpmAvgCurrentIndex .2.12.12.3.1.1 -- acpmAvgCurrentEnable .2.12.12.3.1.2 -- acpmAvgCurrentDeadband .2.12.12.3.1.3 -- acpmAvgCurrentVHighValue .2.12.12.3.1.4 -- acpmAvgCurrentVHighActions .2.12.12.3.1.5 -- acpmAvgCurrentVHighTrapNum .2.12.12.3.1.6 -- acpmAvgCurrentVHighClass .2.12.12.3.1.7 -- acpmAvgCurrentHighValue .2.12.12.3.1.8 -- acpmAvgCurrentHighActions .2.12.12.3.1.9 -- acpmAvgCurrentHighTrapNum .2.12.12.3.1.10 -- acpmAvgCurrentHighClass .2.12.12.3.1.11 -- acpmAvgCurrentNormalActions .2.12.12.3.1.12 -- acpmAvgCurrentNormalTrapNum .2.12.12.3.1.13 -- acpmAvgCurrentNormalClass .2.12.12.3.1.14 -- acpmAvgCurrentLowValue .2.12.12.3.1.15 -- acpmAvgCurrentLowActions .2.12.12.3.1.16 -- acpmAvgCurrentLowTrapNum .2.12.12.3.1.17 -- acpmAvgCurrentLowClass .2.12.12.3.1.18 -- acpmAvgCurrentVLowValue .2.12.12.3.1.19 -- acpmAvgCurrentVLowActions .2.12.12.3.1.20 -- acpmAvgCurrentVLowTrapNum .2.12.12.3.1.21 -- acpmAvgCurrentVLowClass .2.12.12.3.1.22 -- acpmAvgCurrentSysrepEnable .2.12.12.3.1.23 -- acpmAvgCurrentSysrepThreshold .2.12.12.3.1.24 -- acpmAvgCurrentSysrepLimit .2.12.12.3.1.25 -- acpmFreqTable .2.12.12.4 -- acpmFreqEntry .2.12.12.4.1 -- acpmFreqIndex .2.12.12.4.1.1 -- acpmFreqEnable .2.12.12.4.1.2 -- acpmFreqDeadband .2.12.12.4.1.3 -- acpmFreqVHighValue .2.12.12.4.1.4 -- acpmFreqVHighActions .2.12.12.4.1.5 -- acpmFreqVHighTrapNum .2.12.12.4.1.6 -- acpmFreqVHighClass .2.12.12.4.1.7 -- acpmFreqHighValue .2.12.12.4.1.8 -- acpmFreqHighActions .2.12.12.4.1.9 -- acpmFreqHighTrapNum .2.12.12.4.1.10 -- acpmFreqHighClass .2.12.12.4.1.11 -- acpmFreqNormalActions .2.12.12.4.1.12 -- acpmFreqNormalTrapNum .2.12.12.4.1.13 -- acpmFreqNormalClass .2.12.12.4.1.14 -- acpmFreqLowValue .2.12.12.4.1.15 -- acpmFreqLowActions .2.12.12.4.1.16 -- acpmFreqLowTrapNum .2.12.12.4.1.17 -- acpmFreqLowClass .2.12.12.4.1.18 -- acpmFreqVLowValue .2.12.12.4.1.19 -- acpmFreqVLowActions .2.12.12.4.1.20 -- acpmFreqVLowTrapNum .2.12.12.4.1.21 -- acpmFreqVLowClass .2.12.12.4.1.22 -- acpmFreqSysrepEnable .2.12.12.4.1.23 -- acpmFreqSysrepThreshold .2.12.12.4.1.24 -- acpmFreqSysrepLimit .2.12.12.4.1.25 -- acpmTotalRealPowerTable .2.12.12.5 -- acpmTRPEntry .2.12.12.5.1 -- acpmTRPIndex .2.12.12.5.1.1 -- acpmTRPEnable .2.12.12.5.1.2 -- acpmTRPDeadband .2.12.12.5.1.3 -- acpmTRPVHighValue .2.12.12.5.1.4 -- acpmTRPVHighActions .2.12.12.5.1.5 -- acpmTRPVHighTrapNum .2.12.12.5.1.6 -- acpmTRPVHighClass .2.12.12.5.1.7 -- acpmTRPHighValue .2.12.12.5.1.8 -- acpmTRPHighActions .2.12.12.5.1.9 -- acpmTRPHighTrapNum .2.12.12.5.1.10 -- acpmTRPHighClass .2.12.12.5.1.11 -- acpmTRPNormalActions .2.12.12.5.1.12 -- acpmTRPNormalTrapNum .2.12.12.5.1.13 -- acpmTRPNormalClass .2.12.12.5.1.14 -- acpmTRPLowValue .2.12.12.5.1.15 -- acpmTRPLowActions .2.12.12.5.1.16 -- acpmTRPLowTrapNum .2.12.12.5.1.17 -- acpmTRPLowClass .2.12.12.5.1.18 -- acpmTRPVLowValue .2.12.12.5.1.19 -- acpmTRPVLowActions .2.12.12.5.1.20 -- acpmTRPVLowTrapNum .2.12.12.5.1.21 -- acpmTRPVLowClass .2.12.12.5.1.22 -- acpmTRPSysrepEnable .2.12.12.5.1.23 -- acpmTRPSysrepThreshold .2.12.12.5.1.24 -- acpmTRPSysrepLimit .2.12.12.5.1.25 -- acpmDisconnectTable .2.12.12.6 -- acpmDisconnectEntry .2.12.12.6.1 -- acpmDisconnectIndex .2.12.12.6.1.1 -- acpmDisconnectEnable .2.12.12.6.1.2 -- acpmDisconnectActions .2.12.12.6.1.3 -- acpmDisconnectTrapNum .2.12.12.6.1.4 -- acpmDisconnectClass .2.12.12.6.1.5 -- acpmDisconnectNormalActions .2.12.12.6.1.6 -- acpmDisconnectNormalTrapNum .2.12.12.6.1.7 -- acpmDisconnectNormalClass .2.12.12.6.1.8 -- batteryMonitor .2.12.14 -- batteryMonitorGeneralTable .2.12.14.1 -- bmGenEntry .2.12.14.1.1 -- bmGenIndex .2.12.14.1.1.1 -- bmGenEnable .2.12.14.1.1.2 -- bmGenName .2.12.14.1.1.3 -- bmGenBatteryQuantity .2.12.14.1.1.4 -- bmGenBatteryCapacity .2.12.14.1.1.5 -- bmGenBatteryNominalVoltage .2.12.14.1.1.6 -- bmGenSysrepPackage .2.12.14.1.1.7 -- bmGenSysrepType .2.12.14.1.1.8 -- batteryMonitorDeviceTable .2.12.14.2 -- bmDeviceEntry .2.12.14.2.1 -- bmDeviceIndex .2.12.14.2.1.1 -- bmDeviceType .2.12.14.2.1.2 -- bmDeviceES .2.12.14.2.1.3 -- bmDeviceIP .2.12.14.2.1.4 -- bmDeviceReadcom .2.12.14.2.1.5 -- bmDeviceInputString .2.12.14.2.1.6 -- bmDeviceCTSize .2.12.14.2.1.7 -- batteryMonitorTempTable .2.12.14.3 -- bmTempEntry .2.12.14.3.1 -- bmTempIndex .2.12.14.3.1.1 -- bmTempEnable .2.12.14.3.1.2 -- bmTempDeadband .2.12.14.3.1.3 -- bmTempScale .2.12.14.3.1.4 -- bmTempHighValue .2.12.14.3.1.5 -- bmTempHighActions .2.12.14.3.1.6 -- bmTempHighTrapNum .2.12.14.3.1.7 -- bmTempHighClass .2.12.14.3.1.8 -- bmTempNormalActions .2.12.14.3.1.9 -- bmTempNormalTrapNum .2.12.14.3.1.10 -- bmTempNormalClass .2.12.14.3.1.11 -- bmTempLowValue .2.12.14.3.1.12 -- bmTempLowActions .2.12.14.3.1.13 -- bmTempLowTrapNum .2.12.14.3.1.14 -- bmTempLowClass .2.12.14.3.1.15 -- bmTempSysrepEnable .2.12.14.3.1.16 -- bmTempSysrepThreshold .2.12.14.3.1.17 -- bmTempSysrepLimit .2.12.14.3.1.18 -- batteryMonitorDiffTempTable .2.12.14.4 -- bmDiffTempEntry .2.12.14.4.1 -- bmDiffTempIndex .2.12.14.4.1.1 -- bmDiffTempEnable .2.12.14.4.1.2 -- bmDiffTempDeadband .2.12.14.4.1.3 -- bmDiffTempVHighValue .2.12.14.4.1.4 -- bmDiffTempVHighActions .2.12.14.4.1.5 -- bmDiffTempVHighTrapNum .2.12.14.4.1.6 -- bmDiffTempVHighClass .2.12.14.4.1.7 -- bmDiffTempHighValue .2.12.14.4.1.8 -- bmDiffTempHighActions .2.12.14.4.1.9 -- bmDiffTempHighTrapNum .2.12.14.4.1.10 -- bmDiffTempHighClass .2.12.14.4.1.11 -- bmDiffTempNormalActions .2.12.14.4.1.12 -- bmDiffTempNormalTrapNum .2.12.14.4.1.13 -- bmDiffTempNormalClass .2.12.14.4.1.14 -- bmDiffTempSysrepEnable .2.12.14.4.1.15 -- bmDiffTempSysrepThreshold .2.12.14.4.1.16 -- bmDiffTempSysrepLimit .2.12.14.4.1.17 -- batteryMonitorVoltageTable .2.12.14.5 -- bmVoltageEntry .2.12.14.5.1 -- bmVoltageIndex .2.12.14.5.1.1 -- bmVoltageEnable .2.12.14.5.1.2 -- bmVoltageDeadband .2.12.14.5.1.3 -- bmVoltageVHighValue .2.12.14.5.1.4 -- bmVoltageVHighActions .2.12.14.5.1.5 -- bmVoltageVHighTrapNum .2.12.14.5.1.6 -- bmVoltageVHighClass .2.12.14.5.1.7 -- bmVoltageHighValue .2.12.14.5.1.8 -- bmVoltageHighActions .2.12.14.5.1.9 -- bmVoltageHighTrapNum .2.12.14.5.1.10 -- bmVoltageHighClass .2.12.14.5.1.11 -- bmVoltageNormalActions .2.12.14.5.1.12 -- bmVoltageNormalTrapNum .2.12.14.5.1.13 -- bmVoltageNormalClass .2.12.14.5.1.14 -- bmVoltageLowValue .2.12.14.5.1.15 -- bmVoltageLowActions .2.12.14.5.1.16 -- bmVoltageLowTrapNum .2.12.14.5.1.17 -- bmVoltageLowClass .2.12.14.5.1.18 -- bmVoltageVLowValue .2.12.14.5.1.19 -- bmVoltageVLowActions .2.12.14.5.1.20 -- bmVoltageVLowTrapNum .2.12.14.5.1.21 -- bmVoltageVLowClass .2.12.14.5.1.22 -- bmVoltageSysrepEnable .2.12.14.5.1.23 -- bmVoltageSysrepThreshold .2.12.14.5.1.24 -- bmVoltageSysrepLimit .2.12.14.5.1.25 -- batteryMonitorDiffVoltTable .2.12.14.6 -- bmDiffVoltEntry .2.12.14.6.1 -- bmDiffVoltIndex .2.12.14.6.1.1 -- bmDiffVoltEnable .2.12.14.6.1.2 -- bmDiffVoltDeadband .2.12.14.6.1.3 -- bmDiffVoltVHighValue .2.12.14.6.1.4 -- bmDiffVoltVHighActions .2.12.14.6.1.5 -- bmDiffVoltVHighTrapNum .2.12.14.6.1.6 -- bmDiffVoltVHighClass .2.12.14.6.1.7 -- bmDiffVoltHighValue .2.12.14.6.1.8 -- bmDiffVoltHighActions .2.12.14.6.1.9 -- bmDiffVoltHighTrapNum .2.12.14.6.1.10 -- bmDiffVoltHighClass .2.12.14.6.1.11 -- bmDiffVoltNormalActions .2.12.14.6.1.12 -- bmDiffVoltNormalTrapNum .2.12.14.6.1.13 -- bmDiffVoltNormalClass .2.12.14.6.1.14 -- bmDiffVoltSysrepEnable .2.12.14.6.1.15 -- bmDiffVoltSysrepThreshold .2.12.14.6.1.16 -- bmDiffVoltSysrepLimit .2.12.14.6.1.17 -- batteryMonitorChargingCurrentTable .2.12.14.7 -- bmChargingCurrentEntry .2.12.14.7.1 -- bmChargingCurrentIndex .2.12.14.7.1.1 -- bmChargingCurrentEnable .2.12.14.7.1.2 -- bmChargingCurrentDeadband .2.12.14.7.1.3 -- bmChargingCurrentVHighValue .2.12.14.7.1.4 -- bmChargingCurrentVHighActions .2.12.14.7.1.5 -- bmChargingCurrentVHighTrapNum .2.12.14.7.1.6 -- bmChargingCurrentVHighClass .2.12.14.7.1.7 -- bmChargingCurrentHighValue .2.12.14.7.1.8 -- bmChargingCurrentHighActions .2.12.14.7.1.9 -- bmChargingCurrentHighTrapNum .2.12.14.7.1.10 -- bmChargingCurrentHighClass .2.12.14.7.1.11 -- bmChargingCurrentNormalActions .2.12.14.7.1.12 -- bmChargingCurrentNormalTrapNum .2.12.14.7.1.13 -- bmChargingCurrentNormalClass .2.12.14.7.1.14 -- bmChargingCurrentSysrepEnable .2.12.14.7.1.15 -- bmChargingCurrentSysrepThreshold .2.12.14.7.1.16 -- bmChargingCurrentSysrepLimit .2.12.14.7.1.17 -- batteryMonitorDischargingCurrentTable .2.12.14.8 -- bmDischargingCurrentEntry .2.12.14.8.1 -- bmDischargingCurrentIndex .2.12.14.8.1.1 -- bmDischargingCurrentEnable .2.12.14.8.1.2 -- bmDischargingCurrentDeadband .2.12.14.8.1.3 -- bmDischargingCurrentVHighValue .2.12.14.8.1.4 -- bmDischargingCurrentVHighActions .2.12.14.8.1.5 -- bmDischargingCurrentVHighTrapNum .2.12.14.8.1.6 -- bmDischargingCurrentVHighClass .2.12.14.8.1.7 -- bmDischargingCurrentHighValue .2.12.14.8.1.8 -- bmDischargingCurrentHighActions .2.12.14.8.1.9 -- bmDischargingCurrentHighTrapNum .2.12.14.8.1.10 -- bmDischargingCurrentHighClass .2.12.14.8.1.11 -- bmDischargingCurrentNormalActions .2.12.14.8.1.12 -- bmDischargingCurrentNormalTrapNum .2.12.14.8.1.13 -- bmDischargingCurrentNormalClass .2.12.14.8.1.14 -- bmDischargingCurrentSysrepEnable .2.12.14.8.1.15 -- bmDischargingCurrentSysrepThreshold .2.12.14.8.1.16 -- bmDischargingCurrentSysrepLimit .2.12.14.8.1.17 -- batteryMonitorChargeLevelTable .2.12.14.9 -- bmChargeLevelEntry .2.12.14.9.1 -- bmChargeLevelIndex .2.12.14.9.1.1 -- bmChargeLevelEnable .2.12.14.9.1.2 -- bmChargeLevelNormalActions .2.12.14.9.1.3 -- bmChargeLevelNormalTrapNum .2.12.14.9.1.4 -- bmChargeLevelNormalClass .2.12.14.9.1.5 -- bmChargeLevelLowActions .2.12.14.9.1.6 -- bmChargeLevelLowTrapNum .2.12.14.9.1.7 -- bmChargeLevelLowClass .2.12.14.9.1.8 -- bmChargeLevelVLowActions .2.12.14.9.1.9 -- bmChargeLevelVLowTrapNum .2.12.14.9.1.10 -- bmChargeLevelVLowClass .2.12.14.9.1.11 -- bmChargeLevelSysrepEnable .2.12.14.9.1.12 -- batteryMonitorJarHealthTable .2.12.14.10 -- bmJarHealthEntry .2.12.14.10.1 -- bmJarHealthIndex .2.12.14.10.1.1 -- bmJarHealthEnable .2.12.14.10.1.2 -- bmJarHealthNormalActions .2.12.14.10.1.3 -- bmJarHealthNormalTrapNum .2.12.14.10.1.4 -- bmJarHealthNormalClass .2.12.14.10.1.5 -- bmJarHealthLowActions .2.12.14.10.1.6 -- bmJarHealthLowTrapNum .2.12.14.10.1.7 -- bmJarHealthLowClass .2.12.14.10.1.8 -- bmJarHealthVLowActions .2.12.14.10.1.9 -- bmJarHealthVLowTrapNum .2.12.14.10.1.10 -- bmJarHealthVLowClass .2.12.14.10.1.11 -- bmJarHealthSysrepEnable .2.12.14.10.1.12 -- evReset .2.12.16 -- evResetEnable .2.12.16.1 -- evResetDelay .2.12.16.2 -- evResetActions .2.12.16.3 -- evResetMessage .2.12.16.4 -- evResetTrapnum .2.12.16.5 -- evResetClass .2.12.16.6 -- evGlobal .2.12.18 -- evGlobalActions .2.12.18.1 -- evGlobalTrapnum .2.12.18.2 -- action .2.14 -- actionSched .2.14.3 -- actionSchedEnable .2.14.3.1 -- actionSchedBegin .2.14.3.2 -- actionSchedEnd .2.14.3.3 -- actionSchedWeekdaysOnly .2.14.3.4 -- actionAsentria .2.14.4 -- actionAsentriaRequireAck .2.14.4.1 -- actionAsentriaVersion .2.14.4.2 -- actionAsentriaTCPPort .2.14.4.3 -- actionHostTable .2.14.6 -- actionHostEntry .2.14.6.1 -- actionHostIndex .2.14.6.1.1 -- actionHost .2.14.6.1.2 -- actionEmailTable .2.14.7 -- actionEmailEntry .2.14.7.1 -- actionEmailIndex .2.14.7.1.1 -- actionEmail .2.14.7.1.2 -- actionParseError .2.14.8 -- sys .2.16 -- sysTime .2.16.1 -- sysTimeAutoDST .2.16.1.1 -- sysTimeGMTOffset .2.16.1.2 -- sysTimeGMTDirection .2.16.1.3 -- sysTimeNet .2.16.1.4 -- sysTimeNetEnable .2.16.1.4.1 -- sysTimeNetHostTable .2.16.1.4.2 -- sysTimeNetHostEntry .2.16.1.4.2.1 -- sysTimeNetHostIndex .2.16.1.4.2.1.1 -- sysTimeNetHost .2.16.1.4.2.1.2 -- sysPT .2.16.2 -- sysPTTimeout .2.16.2.1 -- sysPTEndPause .2.16.2.2 -- sysMTU .2.16.3 -- sysAnswerString .2.16.4 -- sysEventFileID .2.16.6 -- sysEscapeCharacter .2.16.7 -- sysTimeStamp .2.16.8 -- sysTimeStampTimeFormat .2.16.8.1 -- sysTimeStampDateFormat .2.16.8.2 -- sysTimeStampSpaceAfter .2.16.8.3 -- sysLog .2.16.9 -- sysLogMode .2.16.9.1 -- sysLoghost .2.16.9.2 -- sysLogFilter .2.16.9.3 -- sysLogFileSize .2.16.9.4 -- sysLogFileCount .2.16.9.5 -- sysLogListenPort .2.16.9.6 -- sysCRDB .2.16.10 -- sysCRDBCapacity .2.16.10.1 -- sysCRDBPercentFull .2.16.10.2 -- sysCRDBFileIDTable .2.16.10.3 -- sysCRDBFileIDEntry .2.16.10.3.1 -- sysCRDBFileIDIndex .2.16.10.3.1.1 -- sysCRDBFileID .2.16.10.3.1.2 -- sysCRDBFileEnforceMinTable .2.16.10.4 -- sysCRDBFileEnforceMinEntry .2.16.10.4.1 -- sysCRDBFileEnforceMinIndex .2.16.10.4.1.1 -- sysCRDBFileEnforceMin .2.16.10.4.1.2 -- sysCharMask .2.16.11 -- sysPrompt .2.16.12 -- sysBootStatus .2.16.13 -- sysLoc .2.16.14 -- sysLocLatitude .2.16.14.1 -- sysLocLongitude .2.16.14.2 -- sysLocXOffset .2.16.14.3 -- sysLocYOffset .2.16.14.4 -- sysLocAngle .2.16.14.5 -- sysLocAltitude .2.16.14.6 -- sysFileTransfer .2.16.17 -- sysFileTransferStatus .2.16.17.1 -- sysFileTransferURL .2.16.17.2 -- sysFileTransferUsername .2.16.17.3 -- sysFileTransferPassword .2.16.17.4 -- sysUpdate .2.16.18 -- sysUpdateStatus .2.16.18.1 -- auditLog .2.17 -- auditLogEnable .2.17.1 -- auditLogStoreResets .2.17.2 -- auditLogStoreCommands .2.17.3 -- auditLogStoreRelays .2.17.4 -- auditLogStoreAlarmActions .2.17.5 -- auditLogStorePwdFailures .2.17.6 -- auditLogStoreLogins .2.17.7 -- auditLogStoreSHSK .2.17.8 -- auditLogStorePassthrough .2.17.9 -- auditLogStoreInactivity .2.17.10 -- auditLogStorePolling .2.17.11 -- auditLogMaxSize .2.17.12 -- scripting .2.18 -- scrGlobalEnable .2.18.1 -- scrDTRCtrlPortEnableTable .2.18.2 -- scrDTRCtrlPortEnableEnabletry .2.18.2.1 -- scrDTRCtrlPortEnableIndex .2.18.2.1.1 -- scrDTRCtrlPortEnable .2.18.2.1.2 -- scrTable .2.18.3 -- scrEntry .2.18.3.1 -- scrIndex .2.18.3.1.1 -- scrEnable .2.18.3.1.2 -- scrName .2.18.3.1.3 -- scrFilename .2.18.3.1.4 -- scrRunAlways .2.18.3.1.5 -- scrRunAtStartup .2.18.3.1.6 -- scrRunScheduled .2.18.3.1.7 -- scrScheduleTime .2.18.3.1.8 -- scrArguments .2.18.3.1.9 -- scrRepeatInterval .2.18.3.1.10 -- scrVolatileStringTable .2.18.4 -- scrVolatileStringEntry .2.18.4.1 -- scrVolatileStringIndex .2.18.4.1.1 -- scrVolatileString .2.18.4.1.2 -- scrVolatileIntTable .2.18.5 -- scrVolatileIntEntry .2.18.5.1 -- scrVolatileIntIndex .2.18.5.1.1 -- scrVolatileInt .2.18.5.1.2 -- scrNonVolatileStringTable .2.18.6 -- scrNonVolatileStringEntry .2.18.6.1 -- scrNonVolatileStringIndex .2.18.6.1.1 -- scrNonVolatileString .2.18.6.1.2 -- scrNonVolatileIntTable .2.18.7 -- scrNonVolatileIntEntry .2.18.7.1 -- scrNonVolatileIntIndex .2.18.7.1.1 -- scrNonVolatileInt .2.18.7.1.2 -- generator .2.19 -- genSet .2.19.1 -- genSetEnable .2.19.1.1 -- genSetRelay .2.19.1.2 -- genSetRelayEs .2.19.1.2.1 -- genSetRelayPoint .2.19.1.2.2 -- genSetRelayRunningstate .2.19.1.2.3 -- genSetCc .2.19.1.3 -- genSetCcEnable .2.19.1.3.1 -- genSetCcEs .2.19.1.3.2 -- genSetCcPoint .2.19.1.3.3 -- genSetCcRunningstate .2.19.1.3.4 -- genRun .2.19.2 -- genRunMode .2.19.2.1 -- genRunSched .2.19.2.2 -- genRunDuration .2.19.2.3 -- genRunForce .2.19.2.4 -- genRunReqasm .2.19.2.5 -- genRunStatus .2.19.2.6 -- genRunNonstartEvent .2.19.2.7 -- genRunNonstartEventEnable .2.19.2.7.1 -- genRunNonstartEventActions .2.19.2.7.2 -- genRunNonstartEventTrap .2.19.2.7.3 -- genRunNonstartEventClass .2.19.2.7.4 -- calendar .2.20 -- schedTable .2.20.1 -- schedEntry .2.20.1.1 -- schedIndex .2.20.1.1.1 -- schedEnable .2.20.1.1.2 -- schedStart .2.20.1.1.3 -- schedRepeatMode .2.20.1.1.4 -- schedRepeatFreq .2.20.1.1.5 -- schedRepeatEndMode .2.20.1.1.6 -- schedRepeatEndAfter .2.20.1.1.7 -- schedRepeatEndOn .2.20.1.1.8 -- schedRepeatWeeklySun .2.20.1.1.9 -- schedRepeatWeeklyMon .2.20.1.1.10 -- schedRepeatWeeklyTue .2.20.1.1.11 -- schedRepeatWeeklyWed .2.20.1.1.12 -- schedRepeatWeeklyThu .2.20.1.1.13 -- schedRepeatWeeklyFri .2.20.1.1.14 -- schedRepeatWeeklySat .2.20.1.1.15 -- schedRepeatMonthlyMode .2.20.1.1.16 -- schedRepeatMonthlyDates .2.20.1.1.17 -- schedRepeatMonthlyOnThe .2.20.1.1.18 -- schedRepeatMonthlyOnDay .2.20.1.1.19 -- schedRepeatYearlyJan .2.20.1.1.20 -- schedRepeatYearlyFeb .2.20.1.1.21 -- schedRepeatYearlyMar .2.20.1.1.22 -- schedRepeatYearlyApr .2.20.1.1.23 -- schedRepeatYearlyMay .2.20.1.1.24 -- schedRepeatYearlyJun .2.20.1.1.25 -- schedRepeatYearlyJul .2.20.1.1.26 -- schedRepeatYearlyAug .2.20.1.1.27 -- schedRepeatYearlySep .2.20.1.1.28 -- schedRepeatYearlyOct .2.20.1.1.29 -- schedRepeatYearlyNov .2.20.1.1.30 -- schedRepeatYearlyDec .2.20.1.1.31 -- schedRepeatYearlyOnThe .2.20.1.1.32 -- schedRepeatYearlyOnDay .2.20.1.1.33 -- schedNextTrigger .2.20.1.1.34 -- productIds .3 -- siteName 3.1 -- thisProduct .3.2 -- stockTrapString .3.3 -- trapEventTypeNumber .3.4 -- trapEventTypeName .3.5 -- trapIncludedValue .3.6 -- trapIncludedString .3.7 -- trapTypeString .3.8 -- trapEventClassNumber .3.9 -- trapEventClassName .3.10 -- keyInterface .4.0 --*************************************************************************************** --TOP-LEVEL OBJECT IDENTIFIERS --*************************************************************************************** s450notifications OBJECT IDENTIFIER ::= { s450 0 } --1.3.6.1.4.1.3052.17.0 status OBJECT IDENTIFIER ::= { s450 1 } --1.3.6.1.4.1.3052.17.1 eventSensorStatus OBJECT IDENTIFIER ::= { status 1 } --1.3.6.1.4.1.3052.17.1.1 dataEventStatus OBJECT IDENTIFIER ::= { status 2 } --1.3.6.1.4.1.3052.17.1.2 fuelSensorStatus OBJECT IDENTIFIER ::= { status 6 } --1.3.6.1.4.1.3052.17.1.6 wirelessModemStatus OBJECT IDENTIFIER ::= { status 7 } --1.3.6.1.4.1.3052.17.1.7 acPowerMonitorStatus OBJECT IDENTIFIER ::= { status 8 } --1.3.6.1.4.1.3052.17.1.8 batteryMonitorStatus OBJECT IDENTIFIER ::= { status 10 } --1.3.6.1.4.1.3052.17.1.10 config OBJECT IDENTIFIER ::= { s450 2 } --1.3.6.1.4.1.3052.17.2 eventSensorBasics OBJECT IDENTIFIER ::= { config 1 } --1.3.6.1.4.1.3052.17.2.1 eventSensorPointConfig OBJECT IDENTIFIER ::= { config 2 } --1.3.6.1.4.1.3052.17.2.2 serialPorts OBJECT IDENTIFIER ::= { config 3 } --1.3.6.1.4.1.3052.17.2.3 network OBJECT IDENTIFIER ::= { config 4 } --1.3.6.1.4.1.3052.17.2.4 interface OBJECT IDENTIFIER ::= { network 1 } --1.3.6.1.4.1.3052.17.2.4 ethernet OBJECT IDENTIFIER ::= { interface 1 } --1.3.6.1.4.1.3052.17.2.4.1 ethernet1 OBJECT IDENTIFIER ::= { ethernet 1 } --1.3.6.1.4.1.3052.17.2.4.1.1 eth1VLAN OBJECT IDENTIFIER ::= { ethernet1 5 } --1.3.6.1.4.1.3052.17.2.4.1.1.5 eth1VLAN1 OBJECT IDENTIFIER ::= { eth1VLAN 1 } --1.3.6.1.4.1.3052.17.2.4.1.1.5.1 eth1VLAN2 OBJECT IDENTIFIER ::= { eth1VLAN 2 } --1.3.6.1.4.1.3052.17.2.4.1.1.5.2 eth1VLAN3 OBJECT IDENTIFIER ::= { eth1VLAN 3 } --1.3.6.1.4.1.3052.17.2.4.1.1.5.3 eth1VLAN4 OBJECT IDENTIFIER ::= { eth1VLAN 4 } --1.3.6.1.4.1.3052.17.2.4.1.1.5.4 eth1VLAN5 OBJECT IDENTIFIER ::= { eth1VLAN 5 } --1.3.6.1.4.1.3052.17.2.4.1.1.5.5 eth1VLAN6 OBJECT IDENTIFIER ::= { eth1VLAN 6 } --1.3.6.1.4.1.3052.17.2.4.1.1.5.6 ethernet2 OBJECT IDENTIFIER ::= { ethernet 2 } --1.3.6.1.4.1.3052.17.2.4.1.2 eth2VLAN OBJECT IDENTIFIER ::= { ethernet2 5 } --1.3.6.1.4.1.3052.17.2.4.1.2.5 eth2VLAN1 OBJECT IDENTIFIER ::= { eth2VLAN 1 } --1.3.6.1.4.1.3052.17.2.4.1.2.5.1 eth2VLAN2 OBJECT IDENTIFIER ::= { eth2VLAN 2 } --1.3.6.1.4.1.3052.17.2.4.1.2.5.2 eth2VLAN3 OBJECT IDENTIFIER ::= { eth2VLAN 3 } --1.3.6.1.4.1.3052.17.2.4.1.2.5.3 eth2VLAN4 OBJECT IDENTIFIER ::= { eth2VLAN 4 } --1.3.6.1.4.1.3052.17.2.4.1.2.5.4 eth2VLAN5 OBJECT IDENTIFIER ::= { eth2VLAN 5 } --1.3.6.1.4.1.3052.17.2.4.1.2.5.5 eth2VLAN6 OBJECT IDENTIFIER ::= { eth2VLAN 6 } --1.3.6.1.4.1.3052.17.2.4.1.2.5.6 snmp OBJECT IDENTIFIER ::= { network 8 } --1.3.6.1.4.1.3052.17.2.4.8 snmpNotificationTx OBJECT IDENTIFIER ::= { snmp 7 } --1.3.6.1.4.1.3052.17.2.4.8.7 snmpProxy OBJECT IDENTIFIER ::= { snmp 8 } --1.3.6.1.4.1.3052.17.2.4.8.8 snmpPoll OBJECT IDENTIFIER ::= { snmp 9 } --1.3.6.1.4.1.3052.17.2.4.8.9 ftpPush OBJECT IDENTIFIER ::= { network 9 } --1.3.6.1.4.1.3052.17.2.4.9 routing OBJECT IDENTIFIER ::= { network 11 } --1.3.6.1.4.1.3052.17.2.4.11 netSecurity OBJECT IDENTIFIER ::= { network 12 } --1.3.6.1.4.1.3052.17.2.4.12 ipRestriction OBJECT IDENTIFIER ::= { netSecurity 1 } --1.3.6.1.4.1.3052.17.2.4.12.1 rts OBJECT IDENTIFIER ::= { network 13 } --1.3.6.1.4.1.3052.17.2.4.13 rtsAlarms OBJECT IDENTIFIER ::= { rts 2 } --1.3.6.1.4.1.3052.17.2.4.13.2 trap OBJECT IDENTIFIER ::= { network 14 } --1.3.6.1.4.1.3052.17.2.4.14 trapInclude OBJECT IDENTIFIER ::= { trap 1} --1.3.6.1.4.1.3052.17.2.4.14.1 wireless OBJECT IDENTIFIER ::= { network 16 } --1.3.6.1.4.1.3052.17.2.4.16 email OBJECT IDENTIFIER ::= { network 17 } --1.3.6.1.4.1.3052.17.2.4.17 netAdvanced OBJECT IDENTIFIER ::= { network 18 } --1.3.6.1.4.1.3052.17.2.4.18 web OBJECT IDENTIFIER ::= { network 19 } --1.3.6.1.4.1.3052.17.2.4.19 time OBJECT IDENTIFIER ::= { config 8 } --1.3.6.1.4.1.3052.17.2.8 console OBJECT IDENTIFIER ::= { config 10 } --1.3.6.1.4.1.3052.17.2.10 unitSecurity OBJECT IDENTIFIER ::= { config 11 } --1.3.6.1.4.1.3052.17.2.11 secCore OBJECT IDENTIFIER ::= { unitSecurity 1 } --1.3.6.1.4.1.3052.17.2.11.1 secFactory OBJECT IDENTIFIER ::= { unitSecurity 3 } --1.3.6.1.4.1.3052.17.2.11.3 event OBJECT IDENTIFIER ::= { config 12 } --1.3.6.1.4.1.3052.17.2.12 evCore OBJECT IDENTIFIER ::= { event 1 } --1.3.6.1.4.1.3052.17.2.12.1 evLog OBJECT IDENTIFIER ::= { evCore 3 } --1.3.6.1.4.1.3052.17.2.12.1.3 evMgmt OBJECT IDENTIFIER ::= { evCore 4 } --1.3.6.1.4.1.3052.17.2.12.1.4 evSched1 OBJECT IDENTIFIER ::= { event 5 } --1.3.6.1.4.1.3052.17.2.12.5 evSched2 OBJECT IDENTIFIER ::= { event 6 } --1.3.6.1.4.1.3052.17.2.12.6 evNoSensor OBJECT IDENTIFIER ::= { event 9 } --1.3.6.1.4.1.3052.17.2.12.9 fuelSensor OBJECT IDENTIFIER ::= { event 11 } --1.3.6.1.4.1.3052.17.2.12.11 acPowerMonitor OBJECT IDENTIFIER ::= { event 12 } --1.3.6.1.4.1.3052.17.2.12.12 batteryMonitor OBJECT IDENTIFIER ::= { event 14 } --1.3.6.1.4.1.3052.17.2.12.14 evReset OBJECT IDENTIFIER ::= { event 16 } --1.3.6.1.4.1.3052.17.2.12.16 evGlobal OBJECT IDENTIFIER ::= { event 18 } --1.3.6.1.4.1.3052.17.2.12.18 action OBJECT IDENTIFIER ::= { config 14 } --1.3.6.1.4.1.3052.17.2.14 actionSched OBJECT IDENTIFIER ::= { action 3 } --1.3.6.1.4.1.3052.17.2.14.3 actionAsentria OBJECT IDENTIFIER ::= { action 4 } --1.3.6.1.4.1.3052.17.2.14.4 sys OBJECT IDENTIFIER ::= { config 16 } --1.3.6.1.4.1.3052.17.2.16 sysTime OBJECT IDENTIFIER ::= { sys 1 } --1.3.6.1.4.1.3052.17.2.16.1 sysTimeNet OBJECT IDENTIFIER ::= { sysTime 4 } --1.3.6.1.4.1.3052.17.2.16.1.4 sysPT OBJECT IDENTIFIER ::= { sys 2 } --1.3.6.1.4.1.3052.17.2.16.2 sysTimeStamp OBJECT IDENTIFIER ::= { sys 8 } --1.3.6.1.4.1.3052.17.2.16.8 sysLog OBJECT IDENTIFIER ::= { sys 9 } --1.3.6.1.4.1.3052.17.2.16.9 sysCRDB OBJECT IDENTIFIER ::= { sys 10 } --1.3.6.1.4.1.3052.17.2.16.10 sysLoc OBJECT IDENTIFIER ::= { sys 14 } --1.3.6.1.4.1.3052.17.2.16.14 sysFileTransfer OBJECT IDENTIFIER ::= { sys 17 } --1.3.6.1.4.1.3052.17.2.16.17 sysUpdate OBJECT IDENTIFIER ::= { sys 18 } --1.3.6.1.4.1.3052.17.2.16.18 auditLog OBJECT IDENTIFIER ::= { config 17 } --1.3.6.1.4.1.3052.17.2.17 scripting OBJECT IDENTIFIER ::= { config 18 } --1.3.6.1.4.1.3052.17.2.18 generator OBJECT IDENTIFIER ::= { config 19 } --1.3.6.1.4.1.3052.17.2.19 genSet OBJECT IDENTIFIER ::= { generator 1 } --1.3.6.1.4.1.3052.17.2.19.1 genSetRelay OBJECT IDENTIFIER ::= { genSet 2 } --1.3.6.1.4.1.3052.17.2.19.1.2 genSetCC OBJECT IDENTIFIER ::= { genSet 3 } --1.3.6.1.4.1.3052.17.2.19.1.3 genRun OBJECT IDENTIFIER ::= { generator 2 } --1.3.6.1.4.1.3052.17.2.19.2 genRunNonstartEvent OBJECT IDENTIFIER ::= { genRun 7 } --1.3.6.1.4.1.3052.17.2.19.2.7 calendar OBJECT IDENTIFIER ::= { config 20 } --1.3.6.1.4.1.3052.17.2.20 productIds OBJECT IDENTIFIER ::= { s450 3 } --1.3.6.1.4.1.3052.17.3 --*************************************************************************************** --OBJECT DEFINITIONS --*************************************************************************************** --*************************************************************************************** --EventSensor Status Section 1.1 --*************************************************************************************** esPointTable OBJECT-TYPE SYNTAX SEQUENCE OF ESPoint MAX-ACCESS not-accessible STATUS current DESCRIPTION " This table organizes 4 basic attributes of points. A point is a particular sensor on an EventSensor (e.g., temperature, humidity, contact closure 2, relay 5, etc.). The 4 point attributes are its name, whether it's in its event state, the point's value as a number and its value as a string. Points are referenced by a point index. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point). " ::= { eventSensorStatus 1 } --1.3.6.1.4.1.3052.17.1.1.1 esPointEntry OBJECT-TYPE SYNTAX ESPoint MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for EventSensor point table" INDEX { esIndexES, esIndexPC, esIndexPoint } ::= { esPointTable 1 } --1.3.6.1.4.1.3052.17.1.1.1.1 esIndexES OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "The part of the point index that refers to an EventSensor. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors. The number corresponding to an EventSensor is determined by the user at the initial configuration time. If there is an internal sensor in the unit, it will always be the first item in the Sensor Events setup menu. For example, if a new EventSensor is configured as the 2nd entry AFTER the internal EventSensor (if one exists) in the Sensor Events Setup Menu, then that EventSensor will be known from then on as EventSensor 2. All point indeces with esIndexES=2 will now refer to that particular EventSensor. " ::= { esPointEntry 1 } --1.3.6.1.4.1.3052.17.1.1.1.1.1 esIndexPC OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "The part of the point index that refers to point class. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point). The values for this object are: 1=temperature sensor 2=contact closure 3=humidity sensor 4=noise sensor 5=analog input 6=relay " ::= { esPointEntry 2 } --1.3.6.1.4.1.3052.17.1.1.1.1.2 esIndexPoint OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "The part of the point index that delineates which sensor on the EventSensor. So this combined with esIndexPC (Point Class or type) and esIndexES (which EventSensor) uniquely defines each point (sensor or relay) attached to a unit. For example, if esIndexES is 3, esIndexPC is 1 and esIndexPoint is 4 then this is the Fourth Temperature Sensor on EventSensor number 3." ::= { esPointEntry 3 } --1.3.6.1.4.1.3052.17.1.1.1.1.3 esPointName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the point on an EventSensor. For example, 'AC temp' (in the case of the temperature sensor on an EventSensor). There can be multiple points of the same point class on an EventSensor (e.g., 8 contact closures) and multiple sensor classes on an EventSensor (e.g., temperature, contact closure, humidity). If the point referenced by a given point index is solitary (e.g., temperature sensor, because there can be only one on an EventSensor), then this object reads as ''. Setting this object for solitary point indices sets the EventSensor name only. On the other hand, if a given point is among other points of the same point class on an EventSensor, then this object reads as ''. Setting this object for these NON- solitary point indices sets the sensor name only - not the EventSensor name." ::= { esPointEntry 4 } --1.3.6.1.4.1.3052.17.1.1.1.1.4 esPointInEventState OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "A number referring to the event state of a point on an EventSensor. This number can have different meanings depending on the point class. If the point class is temperature, humidity, or analog input, then the values of this object are: 1=very low 2=low 3=normal 4=high 5=very high For contact closures the values of this object are: 1=point in event state 2=point in normal state For relays the values of this object are: 1=relay energized (active) 2=relay de-energized (inactive) For any point class and any point, if the event state is undefined, then the value of this object is 0. For any point class except relay, this object is read-only. For relays, setting this object to 1 puts the relay into its active (energized) state. Setting it to 2 puts the relay into its inactive (de-energized) state. Setting it to any value greater than 2 puts the relay into its active state for that many seconds (up to 3600), after which time it puts the relay into its inactive state. " ::= { esPointEntry 5 } --1.3.6.1.4.1.3052.17.1.1.1.1.5 esPointValueInt OBJECT-TYPE SYNTAX Integer32 (-2147483648..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "A read-only number referring to the value of a point on an EventSensor. If the point class is temperature, then this object is the temperature in its configured scale (default is Fahrenheit). If the point class is contact closure or relay, then this object is either 0 (open) or 1 (closed). If the point class is humidity, then this object is the percent relative humidity. If the point class is analog input, then this object is the signed input value in tenths of the configured units. If the point class is relay, then this object is either 1 (active a.k.a. energized) or 0 (inactive a.k.a. de-energized). This object cannot be used to control the relay (use esPointInEventState for that). " ::= { esPointEntry 6 } --1.3.6.1.4.1.3052.17.1.1.1.1.6 esPointValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A string referring to the value of a point on an EventSensor. For contact closures this object is either 'Open' or 'Closed'. For relays this object is either 'Active' (energized) or 'Inactive' (de-energized). For temperature and humidity point classes, this object is the string representation of the esPointValueInt object. For temperature, 'C' or 'F' is including in the string to indicate scale. For analog inputs, this object is the string representation of the plus/minus input in the configured units appended with the unit name. " ::= { esPointEntry 7 } --1.3.6.1.4.1.3052.17.1.1.1.1.7 esPointTimeLastChange OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The time of the last time an event was triggerred for a point on an EventSensor in MM/DD/YY HH:MM:SS format. For contact closures, the possible events are Active and Inactive. For temperature, humidity, and analog inputs, the possible events are Normal, High, Very High, Low, and Very Low. For relays, this object is a null string." ::= { esPointEntry 8 } --1.3.6.1.4.1.3052.17.1.1.1.1.8 esPointTimetickLastChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The time of the last time an event was triggerred for a point on an EventSensor in 100ths of seconds since reset. For contact closures, the possible events are Active and Inactive. For temperature, humidity, and analog inputs, the possible events are Normal, High, Very High, Low, and Very Low. For relays, this object is 0." ::= { esPointEntry 9 } --1.3.6.1.4.1.3052.17.1.1.1.1.9 esPointAliasValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "For CC inputs, this is the CC active/inactive alias setting setting value that currently corresponds to the event state. So if the CC input is in the event state, then this object is the active alias setting value. If the CC input is in the normal state, then this object is the inactive alias setting value. For relay/power outputs, this is the output active/inactive alias setting value that currently corresponds to the output state. So if the output is in the active state, then this object is the active alias setting value. If the output is in hte inactive state, then this object is the inactive alias setting value. For non-CC and non-output sensors, this is the same as the esPointValueStr object." ::= { esPointEntry 10 } --1.3.6.1.4.1.3052.17.1.1.1.1.10 --*************************************************************************************** --Data Event Status Section 1.2 --*************************************************************************************** deStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF DEStatus MAX-ACCESS not-accessible STATUS current DESCRIPTION "Data Event Status Table" ::= { dataEventStatus 1 } --1.3.6.1.4.1.3052.17.1.2.1 deStatusEntry OBJECT-TYPE SYNTAX DEStatus MAX-ACCESS not-accessible STATUS current DESCRIPTION "EventSensor status entry" INDEX { deStatusIndex } ::= { deStatusTable 1 } --1.3.6.1.4.1.3052.17.1.2.1.1 deStatusIndex OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for Data Events" ::= { deStatusEntry 1 } --1.3.6.1.4.1.3052.17.1.2.1.1.1 deStatusName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Data Event name" ::= { deStatusEntry 2 } --1.3.6.1.4.1.3052.17.1.2.1.1.2 deStatusCounter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of times a data record has matched this event's equation. Range: 1-999999999" ::= { deStatusEntry 3 } --1.3.6.1.4.1.3052.17.1.2.1.1.3 deStatusThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of times the equation is matched before an event is triggered. Range: 1-999999999" ::= { deStatusEntry 4 } --1.3.6.1.4.1.3052.17.1.2.1.1.4 --*************************************************************************************** --Fuel Sensor 1.5 --*************************************************************************************** fsStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF FSStatus MAX-ACCESS not-accessible STATUS current DESCRIPTION "Fuel sensor status table" ::= { fuelSensorStatus 1 } --1.3.6.1.4.1.3052.17.1.6.1 fsStatusEntry OBJECT-TYPE SYNTAX FSStatus MAX-ACCESS not-accessible STATUS current DESCRIPTION "Fuel sensor status table entry" INDEX { fsStatusIndex } ::= { fsStatusTable 1 } --1.3.6.1.4.1.3052.17.1.6.1.1 fsStatusIndex OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for fuel sensors" ::= { fsStatusEntry 1 } --1.3.6.1.4.1.3052.17.1.6.1.1.1 fsStatusName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Fuel sensor name" ::= { fsStatusEntry 2 } --1.3.6.1.4.1.3052.17.1.6.1.1.2 fsStatusDeviceState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Fuel sensor device state" ::= { fsStatusEntry 3 } --1.3.6.1.4.1.3052.17.1.6.1.1.3 fsStatusVolumeValueString OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Fuel volume. Range is -2,147,483,648 to 2,147,483,647. This value reads -999 when the fuel sensor is disconnected" ::= { fsStatusEntry 4 } --1.3.6.1.4.1.3052.17.1.6.1.1.4 fsStatusVolumePercentLevel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Height of the fluid in the tank expressed as a percentage of the tank height, in hundredths of a percent." ::= { fsStatusEntry 7 } --1.3.6.1.4.1.3052.17.1.6.1.1.7 fsStatusVolumeInEventState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Current event status of the fuel sensor." ::= { fsStatusEntry 8 } --1.3.6.1.4.1.3052.17.1.6.1.1.8 fsStatusCombined OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: deviceState`deviceStateColorCode`percentRounded`valueAsFloat`volumeEventState`volumeEventStateColorCode`capacity`units`name" ::= { fsStatusEntry 9 } --1.3.6.1.4.1.3052.17.1.6.1.1.9 --*************************************************************************************** --Wireless Modem Status Section 1.7 --*************************************************************************************** wmsStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem status" ::= { wirelessModemStatus 1 } --1.3.6.1.4.1.3052.17.1.7.1 wmsSignal OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem Signal strength" ::= { wirelessModemStatus 2 } --1.3.6.1.4.1.3052.17.1.7.2 wmsRSSI OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem Signal strength (RSSI)" ::= { wirelessModemStatus 3 } --1.3.6.1.4.1.3052.17.1.7.3 wmsBER OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem Bit Error Rate" ::= { wirelessModemStatus 4 } --1.3.6.1.4.1.3052.17.1.7.4 wmsUpdated OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem info last update time" ::= { wirelessModemStatus 5 } --1.3.6.1.4.1.3052.17.1.7.5 wmsRegistration OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem registration status" ::= { wirelessModemStatus 6 } --1.3.6.1.4.1.3052.17.1.7.6 wmsLAC OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem Location Area Code" ::= { wirelessModemStatus 7 } --1.3.6.1.4.1.3052.17.1.7.7 wmsCellID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem Cell ID" ::= { wirelessModemStatus 8 } --1.3.6.1.4.1.3052.17.1.7.8 wmsIMSI OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem Internation Mobile Subscriber Identity number" ::= { wirelessModemStatus 9 } --1.3.6.1.4.1.3052.17.1.7.9 wmsPhnum OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem phone number" ::= { wirelessModemStatus 10 } --1.3.6.1.4.1.3052.17.1.7.10 wmsLocalIP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Local IP address of modem on wireless network" ::= { wirelessModemStatus 11 } --1.3.6.1.4.1.3052.17.1.7.11 wmsMgfID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem manufacturer ID" ::= { wirelessModemStatus 12 } --1.3.6.1.4.1.3052.17.1.7.12 wmsModelID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem model ID" ::= { wirelessModemStatus 13 } --1.3.6.1.4.1.3052.17.1.7.13 wmsIMEI OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem International Mobile Equipment Identity number" ::= { wirelessModemStatus 14 } --1.3.6.1.4.1.3052.17.1.7.14 wmsRevID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem revision ID" ::= { wirelessModemStatus 15 } --1.3.6.1.4.1.3052.17.1.7.15 wmsNetName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem network name" ::= { wirelessModemStatus 16 } --1.3.6.1.4.1.3052.17.1.7.16 wmsGPRSStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem (E)GPRS status" ::= { wirelessModemStatus 17 } --1.3.6.1.4.1.3052.17.1.7.17 wmsBand OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem band" ::= { wirelessModemStatus 18 } --1.3.6.1.4.1.3052.17.1.7.18 wmsChannel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem channel" ::= { wirelessModemStatus 19 } --1.3.6.1.4.1.3052.17.1.7.19 wmsCountryCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem country code" ::= { wirelessModemStatus 20 } --1.3.6.1.4.1.3052.17.1.7.20 wmsNetCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem network code" ::= { wirelessModemStatus 21 } --1.3.6.1.4.1.3052.17.1.7.21 wmsPLMNColor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem PLMN color" ::= { wirelessModemStatus 22 } --1.3.6.1.4.1.3052.17.1.7.22 wmsBScolor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem BS color" ::= { wirelessModemStatus 23 } --1.3.6.1.4.1.3052.17.1.7.23 wmsMpRACH OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem max power RACH" ::= { wirelessModemStatus 24 } --1.3.6.1.4.1.3052.17.1.7.24 wmsMinRxLevel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem minimum receive level" ::= { wirelessModemStatus 25 } --1.3.6.1.4.1.3052.17.1.7.25 wmsBaseCoeff OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem base coefficient" ::= { wirelessModemStatus 26 } --1.3.6.1.4.1.3052.17.1.7.26 wmsSIMStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "WWireless modem SIM status" ::= { wirelessModemStatus 27 } --1.3.6.1.4.1.3052.17.1.7.27 wmsICCID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem SIM ICCID" ::= { wirelessModemStatus 28 } --1.3.6.1.4.1.3052.17.1.7.28 wmsModemType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Wireless modem type" ::= { wirelessModemStatus 29 } --1.3.6.1.4.1.3052.17.1.7.29 --*************************************************************************************** --AC Power Monitor Section 1.8 --*************************************************************************************** acpmStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ACPMStatus MAX-ACCESS not-accessible STATUS current DESCRIPTION "AC power monitor status table" ::= { acPowerMonitorStatus 1 } --1.3.6.1.4.1.3052.17.1.8.1 acpmStatusEntry OBJECT-TYPE SYNTAX ACPMStatus MAX-ACCESS not-accessible STATUS current DESCRIPTION "AC power monitor status table entry" INDEX { acpmsIndex } ::= { acpmStatusTable 1 } --1.3.6.1.4.1.3052.17.1.8.1.1 acpmsIndex OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for AC power monitors" ::= { acpmStatusEntry 1 } --1.3.6.1.4.1.3052.17.1.8.1.1.1 acpmsName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name for the AC power monitor device." ::= { acpmStatusEntry 2 } --1.3.6.1.4.1.3052.17.1.8.1.1.2 acpmsAvgVoltageValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Average voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1). This could be either the average of the phase voltages, or the sum of the phase voltages, depending on device configuration." ::= { acpmStatusEntry 3 } --1.3.6.1.4.1.3052.17.1.8.1.1.3 acpmsAvgVoltageMinStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum average voltage value since last reset, in volts." ::= { acpmStatusEntry 4 } --1.3.6.1.4.1.3052.17.1.8.1.1.4 acpmsAvgVoltageMaxStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum average voltage value since last reset, in volts." ::= { acpmStatusEntry 5 } --1.3.6.1.4.1.3052.17.1.8.1.1.5 acpmsAvgVoltageAvgStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Average average voltage value since last reset, in volts. This is the unit's average of its measurements of the average voltage reported by the AC power monitor device." ::= { acpmStatusEntry 6 } --1.3.6.1.4.1.3052.17.1.8.1.1.6 acpmsAvgVoltageInEventState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Event state of this AC power monitor voltage (Low, Normal, High, etc.)." ::= { acpmStatusEntry 7 } --1.3.6.1.4.1.3052.17.1.8.1.1.7 acpmsVoltagePhaseAValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase A voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1)." ::= { acpmStatusEntry 8 } --1.3.6.1.4.1.3052.17.1.8.1.1.8 acpmsVoltagePhaseBValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase B voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1)." ::= { acpmStatusEntry 9 } --1.3.6.1.4.1.3052.17.1.8.1.1.9 acpmsVoltagePhaseCValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase C voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1)." ::= { acpmStatusEntry 10 } --1.3.6.1.4.1.3052.17.1.8.1.1.10 acpmsAvgCurrentValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Average current, in amps. This is calculated using the formula (register * CT ratio * 0.001). This could be either the average of the phase currents, or the sum of the phase currents, depending on device configuration." ::= { acpmStatusEntry 11 } --1.3.6.1.4.1.3052.17.1.8.1.1.11 acpmsAvgCurrentMinStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum average current value since last reset, in amps." ::= { acpmStatusEntry 12 } --1.3.6.1.4.1.3052.17.1.8.1.1.12 acpmsAvgCurrentMaxStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum average current value since last reset, in amps." ::= { acpmStatusEntry 13 } --1.3.6.1.4.1.3052.17.1.8.1.1.13 acpmsAvgCurrentAvgStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Average average current value since last reset, in amps. This is the unit's average of its measurements of the average current reported by the AC power monitor device." ::= { acpmStatusEntry 14 } --1.3.6.1.4.1.3052.17.1.8.1.1.14 acpmsAvgCurrentInEventState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Event state of this AC power monitor current (Low, Normal, High, etc.)." ::= { acpmStatusEntry 15 } --1.3.6.1.4.1.3052.17.1.8.1.1.15 acpmsCurrentPhaseAValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase A current, in amps. This is calculated using the formula (register * CT ratio * 0.001)." ::= { acpmStatusEntry 16 } --1.3.6.1.4.1.3052.17.1.8.1.1.16 acpmsCurrentPhaseBValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase B current, in amps. This is calculated using the formula (register * CT ratio * 0.001)." ::= { acpmStatusEntry 17 } --1.3.6.1.4.1.3052.17.1.8.1.1.17 acpmsCurrentPhaseCValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase C current, in amps. This is calculated using the formula (register * CT ratio * 0.001)." ::= { acpmStatusEntry 18 } --1.3.6.1.4.1.3052.17.1.8.1.1.18 acpmsAvgFreqValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Frequency, in hertz. On the YD2010, this is calculated using the formula (register * 0.00106813). On the WattsOn, this is calculated using the formula (register * 0.1)." ::= { acpmStatusEntry 19 } --1.3.6.1.4.1.3052.17.1.8.1.1.19 acpmsAvgFreqMinStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum frequency value since last reset, in hertz." ::= { acpmStatusEntry 20 } --1.3.6.1.4.1.3052.17.1.8.1.1.20 acpmsAvgFreqMaxStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum frequency value since last reset, in hertz." ::= { acpmStatusEntry 21 } --1.3.6.1.4.1.3052.17.1.8.1.1.21 acpmsAvgFreqAvgStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Average frequency value since last reset, in hertz. This is the unit's average of its measurements of the average frequency reported by the AC power monitor device." ::= { acpmStatusEntry 22 } --1.3.6.1.4.1.3052.17.1.8.1.1.22 acpmsAvgFreqInEventState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Event state of this AC power monitor frequency (Low, Normal, High, etc.)." ::= { acpmStatusEntry 23 } --1.3.6.1.4.1.3052.17.1.8.1.1.23 acpmsTRPValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Total real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range taken from register 0x30A. On the WattsOn models, this is calculated using the formula (register * PT * CT)." ::= { acpmStatusEntry 24 } --1.3.6.1.4.1.3052.17.1.8.1.1.24 acpmsTRPMinStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum total real power value since last reset, in watts." ::= { acpmStatusEntry 25 } --1.3.6.1.4.1.3052.17.1.8.1.1.25 acpmsTRPMaxStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum total real power value since last reset, in watts." ::= { acpmStatusEntry 26 } --1.3.6.1.4.1.3052.17.1.8.1.1.26 acpmsTRPAvgStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Average total real power value since last reset, in watts. This is the unit's average of its measurements of the average total real power reported by the AC power monitor device." ::= { acpmStatusEntry 27 } --1.3.6.1.4.1.3052.17.1.8.1.1.27 acpmsTRPInEventState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Event state of this AC power monitor total real power (Low, Normal, High, etc.)." ::= { acpmStatusEntry 28 } --1.3.6.1.4.1.3052.17.1.8.1.1.28 acpmsRPPhaseAValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase A real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range taken from register 0x30A. On the WattsOn, this is calculated using the formula (register * PT * CT)." ::= { acpmStatusEntry 29 } --1.3.6.1.4.1.3052.17.1.8.1.1.29 acpmsRPPhaseBValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase B real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range taken from register 0x30A. On the WattsOn, this is calculated using the formula (register * PT * CT)." ::= { acpmStatusEntry 30 } --1.3.6.1.4.1.3052.17.1.8.1.1.30 acpmsRPPhaseCValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase C real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range taken from register 0x30A. On the WattsOn, this is calculated using the formula (register * PT * CT)." ::= { acpmStatusEntry 31 } --1.3.6.1.4.1.3052.17.1.8.1.1.31 acpmsCombined OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: name`deviceState`deviceStateColorCode`voltage`current`frequency`power~voltageEventState`voltageColorCode`currentEventState`currentColorCode`frequencyEventState`frequencyColorCode`powerEventState`powerColorCode" ::= { acpmStatusEntry 32 } --1.3.6.1.4.1.3052.17.1.8.1.1.32 acpmsTPFValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Total power factor." ::= { acpmStatusEntry 33 } --1.3.6.1.4.1.3052.17.1.8.1.1.33 acpmsTPFMinStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Total power factor minimum value since last reset." ::= { acpmStatusEntry 34 } --1.3.6.1.4.1.3052.17.1.8.1.1.34 acpmsTPFMaxStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Total power factor maximum value since last reset." ::= { acpmStatusEntry 35 } --1.3.6.1.4.1.3052.17.1.8.1.1.35 acpmsTPFAvgStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Total power factor average value since last reset." ::= { acpmStatusEntry 36 } --1.3.6.1.4.1.3052.17.1.8.1.1.36 acpmsTPFInEventState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Total power factor event state." ::= { acpmStatusEntry 37 } --1.3.6.1.4.1.3052.17.1.8.1.1.37 acpmsPFPhaseAValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase A power factor." ::= { acpmStatusEntry 38 } --1.3.6.1.4.1.3052.17.1.8.1.1.38 acpmsPFPhaseBValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase B power factor." ::= { acpmStatusEntry 39 } --1.3.6.1.4.1.3052.17.1.8.1.1.39 acpmsPFPhaseCValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase C power factor." ::= { acpmStatusEntry 40 } --1.3.6.1.4.1.3052.17.1.8.1.1.40 acpmsTRcPValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Total reactive power, in VAR." ::= { acpmStatusEntry 41 } --1.3.6.1.4.1.3052.17.1.8.1.1.41 acpmsTRcPMinStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Total reactive power minimum value since last reset, in VAR." ::= { acpmStatusEntry 42 } --1.3.6.1.4.1.3052.17.1.8.1.1.42 acpmsTRcPMaxStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Total reactive power maximum value since last reset, in VAR." ::= { acpmStatusEntry 43 } --1.3.6.1.4.1.3052.17.1.8.1.1.43 acpmsTRcPAvgStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Total reactive power average value since last reset, in VAR." ::= { acpmStatusEntry 44 } --1.3.6.1.4.1.3052.17.1.8.1.1.44 acpmsRcPPhaseAValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase A reactive power, in VAR." ::= { acpmStatusEntry 45 } --1.3.6.1.4.1.3052.17.1.8.1.1.45 acpmsRcPPhaseBValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase B reactive power, in VAR." ::= { acpmStatusEntry 46 } --1.3.6.1.4.1.3052.17.1.8.1.1.46 acpmsRcPPhaseCValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase C reactive power, in VAR." ::= { acpmStatusEntry 47 } --1.3.6.1.4.1.3052.17.1.8.1.1.47 acpmsTAPValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Total apparent power, in VA." ::= { acpmStatusEntry 48 } --1.3.6.1.4.1.3052.17.1.8.1.1.48 acpmsTAPMinStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Total apparent power minimum value since last reset, in VA." ::= { acpmStatusEntry 49 } --1.3.6.1.4.1.3052.17.1.8.1.1.49 acpmsTAPMaxStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Total apparent power maximum value since last reset, in VA." ::= { acpmStatusEntry 50 } --1.3.6.1.4.1.3052.17.1.8.1.1.50 acpmsTAPAvgStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Total apparent power average value since last reset, in VA." ::= { acpmStatusEntry 51 } --1.3.6.1.4.1.3052.17.1.8.1.1.51 acpmsAPPhaseAValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase A apparent power, in VA." ::= { acpmStatusEntry 52 } --1.3.6.1.4.1.3052.17.1.8.1.1.52 acpmsAPPhaseBValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase B apparent power, in VA." ::= { acpmStatusEntry 53 } --1.3.6.1.4.1.3052.17.1.8.1.1.53 acpmsAPPhaseCValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Phase C apparent power, in VA." ::= { acpmStatusEntry 54 } --1.3.6.1.4.1.3052.17.1.8.1.1.54 acpmsTotalEnergyWh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total energy, in Wh." ::= { acpmStatusEntry 55 } --1.3.6.1.4.1.3052.17.1.8.1.1.55 acpmsTotalEnergyVAR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total reactive energy, in VAR." ::= { acpmStatusEntry 56 } --1.3.6.1.4.1.3052.17.1.8.1.1.56 acpmsTotalEnergyVA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total apparent energy, in VA." ::= { acpmStatusEntry 57 } --1.3.6.1.4.1.3052.17.1.8.1.1.57 --*************************************************************************************** --Battery Monitor Status Section 1.10 --*************************************************************************************** bmStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF BMStatus MAX-ACCESS not-accessible STATUS current DESCRIPTION "Battery monitor status table." ::= { batteryMonitorStatus 1 } --1.3.6.1.4.1.3052.17.1.10.1 bmStatusEntry OBJECT-TYPE SYNTAX BMStatus MAX-ACCESS not-accessible STATUS current DESCRIPTION "Battery monitor status table entry." INDEX { bmsIndex } ::= { bmStatusTable 1 } --1.3.6.1.4.1.3052.17.1.10.1.1 bmsIndex OBJECT-TYPE SYNTAX Integer32 (1..9) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for battery monitors." ::= { bmStatusEntry 1 } --1.3.6.1.4.1.3052.17.1.10.1.1.1 bmsEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "ON/OFF enable for this battery monitor." ::= { bmStatusEntry 2 } --1.3.6.1.4.1.3052.17.1.10.1.1.2 bmsName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name for this battery monitor." ::= { bmStatusEntry 3 } --1.3.6.1.4.1.3052.17.1.10.1.1.3 bmsState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The connected state of the battery monitor. If you unplug the carrier then all three of its battery monitor states will reflect the same state change." ::= { bmStatusEntry 4 } --1.3.6.1.4.1.3052.17.1.10.1.1.4 bmsStringState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "State of the string monitored by its battery monitor." ::= { bmStatusEntry 5 } --1.3.6.1.4.1.3052.17.1.10.1.1.5 bmsTempValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Average jar temperature value in C or F, depending on scale setting. Displayed as a floating point value. -999.0 means this is unknown." ::= { bmStatusEntry 6 } --1.3.6.1.4.1.3052.17.1.10.1.1.6 bmsTempValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Average jar temperature with appropriate scale appended. Displayed as a floating point value. -999.0 means this is unknown." ::= { bmStatusEntry 7 } --1.3.6.1.4.1.3052.17.1.10.1.1.7 bmsTempEvent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Event state of this battery monitor average jar temperature (Low, Normal, High)." ::= { bmStatusEntry 8 } --1.3.6.1.4.1.3052.17.1.10.1.1.8 bmsDiffTempValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Differential temperature in C or F, depending on scale setting. -999 means this is unknown." ::= { bmStatusEntry 9 } --1.3.6.1.4.1.3052.17.1.10.1.1.9 bmsDiffTempValueStr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Differential temperature with appropriate scale (C or F) appended. -999 means this is unknown." ::= { bmStatusEntry 10 } --1.3.6.1.4.1.3052.17.1.10.1.1.10 bmsDiffTempEvent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Event state of this battery monitor differential temperature (Very High, High, Normal)." ::= { bmStatusEntry 11 } --1.3.6.1.4.1.3052.17.1.10.1.1.11 bmsVoltageValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Total battery voltage on the string, in volts. Displayed as a floating point value in format X.X. -999.0 means this is unknown." ::= { bmStatusEntry 12 } --1.3.6.1.4.1.3052.17.1.10.1.1.12 bmsVoltageEvent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Event state of this battery monitor string voltage (Low, Normal, High, etc.)." ::= { bmStatusEntry 13 } --1.3.6.1.4.1.3052.17.1.10.1.1.13 bmsDiffVoltValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Differential voltage in volts. Displayed as a floating point value in format X.X. -999.0 means this is unknown." ::= { bmStatusEntry 14 } --1.3.6.1.4.1.3052.17.1.10.1.1.14 bmsDiffVoltEvent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Event state of this battery monitor differential voltage (Very High, High, Normal.)" ::= { bmStatusEntry 15 } --1.3.6.1.4.1.3052.17.1.10.1.1.15 bmsCurrentValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Current flow on the string, in amperes. Displayed as a floating point value in format X.X. A positive value means the battery string is charging, and a negative value means the battery string is discharging. -999.0 means this is unknown." ::= { bmStatusEntry 16 } --1.3.6.1.4.1.3052.17.1.10.1.1.16 bmsChargingCurrentEvent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Event state of this battery monitor charging current (Low, Normal, High, etc.)." ::= { bmStatusEntry 17 } --1.3.6.1.4.1.3052.17.1.10.1.1.17 bmsDischargingCurrentEvent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Event state of this battery monitor discharging current (Low, Normal, High, etc.)." ::= { bmStatusEntry 18 } --1.3.6.1.4.1.3052.17.1.10.1.1.18 bmsChargeLevelValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Charge level of the battery string." ::= { bmStatusEntry 19 } --1.3.6.1.4.1.3052.17.1.10.1.1.19 bmsChargeLevelEvent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Event state of this battery monitor charge level (Very Low, Low, Normal)." ::= { bmStatusEntry 20 } --1.3.6.1.4.1.3052.17.1.10.1.1.20 bmsJarHealthValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Jar health of the battery string." ::= { bmStatusEntry 21 } --1.3.6.1.4.1.3052.17.1.10.1.1.21 bmsJarHealthEvent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Event state of this battery monitor jar health (Very Low, Low, Normal)." ::= { bmStatusEntry 22 } --1.3.6.1.4.1.3052.17.1.10.1.1.22 bmsCombined OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: name`deviceState`deviceStateColorCode`stringState`charge`voltage`temp`health~chargeEventState`chargeColorCode`voltageEventState`voltageColorCode`tempEventState`tempColorCode`healthEventState`healthColorCode`numActiveEvents" ::= { bmStatusEntry 23 } --1.3.6.1.4.1.3052.17.1.10.1.1.23 bmsJarStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF BMJarStatus MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes per-jar attributes of a battery monitor: 1. voltage 2. temperature." ::= { batteryMonitorStatus 2 } --1.3.6.1.4.1.3052.17.1.10.2 bmJarStatusEntry OBJECT-TYPE SYNTAX BMJarStatus MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for battery monitor jar status table. Note this table uses 2 SNMP indexes: the first for which battery monitor and the second for which jar." INDEX { bmjsIndexBM, bmjsIndexJar } ::= { bmsJarStatusTable 1 } --1.3.6.1.4.1.3052.17.1.10.2.1 bmjsIndexBM OBJECT-TYPE SYNTAX Integer32 (1..9) MAX-ACCESS read-only STATUS current DESCRIPTION "The part of the index that refers to which battery monitor." ::= { bmJarStatusEntry 1 } --1.3.6.1.4.1.3052.17.1.10.2.1.1 bmjsIndexJar OBJECT-TYPE SYNTAX Integer32 (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "The part of the index that refers to which jar." ::= { bmJarStatusEntry 2 } --1.3.6.1.4.1.3052.17.1.10.2.1.2 bmjsVoltageValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Voltage of individual battery cell. This is a floating point value in format X.X. -999.0 means this is unknown." ::= { bmJarStatusEntry 3 } --1.3.6.1.4.1.3052.17.1.10.2.1.3 bmjsTempValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of individual battery jar. This is a floating point value. -999.0 means unknown." ::= { bmJarStatusEntry 4 } --1.3.6.1.4.1.3052.17.1.10.2.1.4 bmjsAdmittanceValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Cell admittance of individual jar. This is an integer value. -999 means unknown." ::= { bmJarStatusEntry 5 } --1.3.6.1.4.1.3052.17.1.10.2.1.5 bmjsAdmittanceChangeValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Percent change of cell admittance of individual jar. This is an integer value." ::= { bmJarStatusEntry 6 } --1.3.6.1.4.1.3052.17.1.10.2.1.6 --*************************************************************************************** --EventSensor Basics Section 2.1 --*************************************************************************************** esNumberEventSensors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of EventSensors recognized by the unit, including the internal EventSensor. Range: 1-17" ::= { eventSensorBasics 1 } --1.3.6.1.4.1.3052.17.2.1.1 esTable OBJECT-TYPE SYNTAX SEQUENCE OF ESExist MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of what EventSensors are attached to the unit, including the internal EventSensor" ::= { eventSensorBasics 2 } --1.3.6.1.4.1.3052.17.2.1.2 esEntry OBJECT-TYPE SYNTAX ESExist MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table entry for EventSensor table" INDEX { esIndex } ::= { esTable 1 } --1.3.6.1.4.1.3052.17.2.1.2.1 esIndex OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "This number refers to an EventSensor; it has the same meaning as the esIndexES object (see above), except that this object is used only within the esTable branch. This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors. The number corresponding to an EventSensor is determined by the user at the initial configuration time. If there is an internal sensor in the unit, it will always be the first item in the Sensor Events setup menu. For example, if a new EventSensor is configured as the 2nd entry AFTER the internal EventSensor (if one exists) in the Sensor Events Setup Menu, then that EventSensor will be known from then on as EventSensor 2. All point indeces with esIndex=2 will now refer to that particular EventSensor. " ::= { esEntry 1 } --1.3.6.1.4.1.3052.17.2.1.2.1.1 esName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the EventSensor" ::= { esEntry 2 } --1.3.6.1.4.1.3052.17.2.1.2.1.2 esID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The factory-assigned ID of the EventSensor" ::= { esEntry 3 } --1.3.6.1.4.1.3052.17.2.1.2.1.3 esNumberTempSensors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of temperature sensors on the EventSensor" ::= { esEntry 4 } --1.3.6.1.4.1.3052.17.2.1.2.1.4 esTempReportingMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of how temperature values should be interpreted." ::= { esEntry 5 } --1.3.6.1.4.1.3052.17.2.1.2.1.5 esNumberCCs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of contact closures on the EventSensor." ::= { esEntry 6 } --1.3.6.1.4.1.3052.17.2.1.2.1.6 esCCReportingMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of how CC values should be interpreted." ::= { esEntry 7 } --1.3.6.1.4.1.3052.17.2.1.2.1.7 esNumberHumidSensors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of humidity sensors on the EventSensor." ::= { esEntry 8 } --1.3.6.1.4.1.3052.17.2.1.2.1.8 esHumidReportingMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of how humidity sensor values should be interpreted." ::= { esEntry 9 } --1.3.6.1.4.1.3052.17.2.1.2.1.9 esNumberNoiseSensors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of noise sensors on the EventSensor." ::= { esEntry 10 } --1.3.6.1.4.1.3052.17.2.1.2.1.10 esNoiseReportingMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of how noise sensor values should be interpreted." ::= { esEntry 11 } --1.3.6.1.4.1.3052.17.2.1.2.1.11 esNumberAirflowSensors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of airflow sensors on the EventSensor." ::= { esEntry 12 } --1.3.6.1.4.1.3052.17.2.1.2.1.12 esAirflowReportingMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of how airflow sensor values should be interpreted." ::= { esEntry 13 } --1.3.6.1.4.1.3052.17.2.1.2.1.13 esNumberAnalog OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of analog inputs on the EventSensor." ::= { esEntry 14 } --1.3.6.1.4.1.3052.17.2.1.2.1.14 esAnalogReportingMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of how analog input values should be interpreted." ::= { esEntry 15 } --1.3.6.1.4.1.3052.17.2.1.2.1.15 esNumberRelayOutputs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of relay outputs on the EventSensor" ::= { esEntry 16 } --1.3.6.1.4.1.3052.17.2.1.2.1.16 esRelayReportingMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of how relay output values should be interpreted." ::= { esEntry 17 } --1.3.6.1.4.1.3052.17.2.1.2.1.17 esTempCombinedStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: name`value`scale`eventState`eventColorCode" ::= { esEntry 18 } --1.3.6.1.4.1.3052.17.2.1.2.1.18 esCCCombinedStatusBlock1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: numInBlock~name1`value1`eventColorCode1`alias1~name2`value2`eventColorCode2`alias2~...name8`value8`eventColorCode8`alias8" ::= { esEntry 19 } --1.3.6.1.4.1.3052.17.2.1.2.1.19 esCCCombinedStatusBlock2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: numInBlock~name9`value9`eventColorCode9`alias9~name10`value10`eventColorCode10`alias10~...name16`value16`eventColorCode16`alias16" ::= { esEntry 20 } --1.3.6.1.4.1.3052.17.2.1.2.1.20 esCCCombinedStatusBlock3 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: numInBlock~name17`value17`eventColorCode17`alias17~name18`value18`eventColorCode18`alias18~...name24`value24`eventColorCode24`alias24" ::= { esEntry 21 } --1.3.6.1.4.1.3052.17.2.1.2.1.21 esCCCombinedStatusBlock4 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: numInBlock~name25`value25`eventColorCode25`alias25~name26`value26`eventColorCode26`alias26~...name32`value32`eventColorCode32`alias32" ::= { esEntry 22 } --1.3.6.1.4.1.3052.17.2.1.2.1.22 esCCCombinedStatusBlock5 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: numInBlock~name33`value33`eventColorCode33`alias33~name34`value34`eventColorCode34`alias35~...name40`value40`eventColorCode40`alias40" ::= { esEntry 23 } --1.3.6.1.4.1.3052.17.2.1.2.1.23 esCCCombinedStatusBlock6 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: numInBlock~name41`value41`eventColorCode41`alias41~name42`value42`eventColorCode42`alias43~...name48`value48`eventColorCode48`alias48" ::= { esEntry 24 } --1.3.6.1.4.1.3052.17.2.1.2.1.24 esCCCombinedStatusBlock7 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: numInBlock~name49`value49`eventColorCode49`alias49~name50`value50`eventColorCode50`alias50~...name56`value56`eventColorCode56`alias56" ::= { esEntry 25 } --1.3.6.1.4.1.3052.17.2.1.2.1.25 esCCCombinedStatusBlock8 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: numInBlock~name57`value57`eventColorCode57`alias57~name57`value57`eventColorCode564`alias57~...name64`value64`eventColorCode64`alias64" ::= { esEntry 26 } --1.3.6.1.4.1.3052.17.2.1.2.1.26 esHumidCombinedStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: name`value`eventState`eventColorCode" ::= { esEntry 27 } --1.3.6.1.4.1.3052.17.2.1.2.1.27 esAnalogCombinedStatusBlock1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: numInBlock~name1`value1`units1`eventState`eventColorCode1~name2`value2`units2`eventState`eventColorCode2~..." ::= { esEntry 28 } --1.3.6.1.4.1.3052.17.2.1.2.1.28 esAnalogCombinedStatusBlock2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: numInBlock~name9`value9`units9`eventState9`eventColorCode9~..." ::= { esEntry 29 } --1.3.6.1.4.1.3052.17.2.1.2.1.29 esAnalogCombinedStatusBlock3 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..." ::= { esEntry 30 } --1.3.6.1.4.1.3052.17.2.1.2.1.31 esAnalogCombinedStatusBlock4 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..." ::= { esEntry 31 } --1.3.6.1.4.1.3052.17.2.1.2.1.31 esAnalogCombinedStatusBlock5 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..." ::= { esEntry 32 } --1.3.6.1.4.1.3052.17.2.1.2.1.32 esAnalogCombinedStatusBlock6 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..." ::= { esEntry 33 } --1.3.6.1.4.1.3052.17.2.1.2.1.33 esOutputCombinedStatusBlock1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~..." ::= { esEntry 34 } --1.3.6.1.4.1.3052.17.2.1.2.1.34 esOutputCombinedStatusBlock2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Combined status string intended to be parsed by NMS: numInBlock`namex`valuex`aliasx~namey`valuey`aliasy~...namez`valuez`aliasz" ::= { esEntry 35 } --1.3.6.1.4.1.3052.17.2.1.2.1.35 esNewSensors OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "String representing the number of new (attached but unconfigured) EventSensors" ::= { eventSensorBasics 3 } --1.3.6.1.4.1.3052.17.2.1.3 --*************************************************************************************** --EventSensor Point Config Section 2.2 --*************************************************************************************** esPointConfigTempTable OBJECT-TYPE SYNTAX SEQUENCE OF ESPointConfigTemp MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes 3 basic attributes of temperature sensor points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number (always 1 for temp sensors) Points are referenced by a point config index. The point config index is a string of 2 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor within the context of this emperature point config table ; namely, which EventSensor, and which sensor (a.k.a. point) (always 1 for temperature sensors). " ::= { eventSensorPointConfig 1 } --1.3.6.1.4.1.3052.17.2.2.1 esPointConfigTempEntry OBJECT-TYPE SYNTAX ESPointConfigTemp MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for EventSensor point config temperature table" INDEX { espcTempIndexES, espcTempIndexPoint } ::= { esPointConfigTempTable 1 } --1.3.6.1.4.1.3052.17.2.2.1.1 espcTempIndexES OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "The part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config temperature table; namely, which EventSensor, and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors. The number corresponding to an EventSensor is determined by the user at the initial configuration time. If there is an internal sensor in the unit, it will always be the first item in the Sensor Events setup menu. For example, if a new EventSensor is configured as the 2nd entry AFTER the internal EventSensor (if one exists) in the Sensor Events Setup Menu, then that EventSensor will be known from then on as EventSensor 2. All point indeces with esIndexES=2 will now refer to that particular EventSensor. " ::= { esPointConfigTempEntry 1 } --1.3.6.1.4.1.3052.17.2.2.1.1.1 espcTempIndexPoint OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "The part of the point index that delineates which sensor on the EventSensor. So this combined with espcTempIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of temperature point configuration." ::= { esPointConfigTempEntry 2 } --1.3.6.1.4.1.3052.17.2.2.1.1.2 espcTempEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF enable this temperature sensor" ::= { esPointConfigTempEntry 3 } --1.3.6.1.4.1.3052.17.2.2.1.1.3 espcTempScale OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Scale (C/F) for this temperature sensor" ::= { esPointConfigTempEntry 4 } --1.3.6.1.4.1.3052.17.2.2.1.1.4 espcTempDeadband OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Deadband for this temperature sensor (in floating-point format)" ::= { esPointConfigTempEntry 5 } --1.3.6.1.4.1.3052.17.2.2.1.1.5 espcTempVHighTemp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high temperature event threshold for this temperature sensor (in floating-point format)" ::= { esPointConfigTempEntry 6 } --1.3.6.1.4.1.3052.17.2.2.1.1.6 espcTempVHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high temperature event actions for this temperature sensor" ::= { esPointConfigTempEntry 7 } --1.3.6.1.4.1.3052.17.2.2.1.1.7 espcTempVHighTrapnum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Very high temperature event trap number for this temperature sensor" ::= { esPointConfigTempEntry 8 } --1.3.6.1.4.1.3052.17.2.2.1.1.8 espcTempVHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high temperature event class for this temperature sensor" ::= { esPointConfigTempEntry 9 } --1.3.6.1.4.1.3052.17.2.2.1.1.9 espcTempHighTemp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High temperature event threshold for this temperature sensor (in floating-point format)" ::= { esPointConfigTempEntry 10 } --1.3.6.1.4.1.3052.17.2.2.1.1.10 espcTempHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High temperature event actions for this temperature sensor" ::= { esPointConfigTempEntry 11 } --1.3.6.1.4.1.3052.17.2.2.1.1.11 espcTempHighTrapnum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "High temperature event trap number for this temperature sensor" ::= { esPointConfigTempEntry 12 } --1.3.6.1.4.1.3052.17.2.2.1.1.12 espcTempHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High temperature event class for this temperature sensor" ::= { esPointConfigTempEntry 13 } --1.3.6.1.4.1.3052.17.2.2.1.1.13 espcTempNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return-to-normal event actions for this temperature sensor" ::= { esPointConfigTempEntry 14 } --1.3.6.1.4.1.3052.17.2.2.1.1.14 espcTempNormalTrapnum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Return-to-normal event trap number for this temperature sensor" ::= { esPointConfigTempEntry 15 } --1.3.6.1.4.1.3052.17.2.2.1.1.15 espcTempNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return-to-normal event class for this temperature sensor" ::= { esPointConfigTempEntry 16 } --1.3.6.1.4.1.3052.17.2.2.1.1.16 espcTempLowTemp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low temperature event threshold for this temperature sensor (in floating-point format)" ::= { esPointConfigTempEntry 17 } --1.3.6.1.4.1.3052.17.2.2.1.1.17 espcTempLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low temperature event actions for this temperature sensor" ::= { esPointConfigTempEntry 18 } --1.3.6.1.4.1.3052.17.2.2.1.1.18 espcTempLowTrapnum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Low temperature event trap number for this temperature sensor" ::= { esPointConfigTempEntry 19 } --1.3.6.1.4.1.3052.17.2.2.1.1.19 espcTempLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low temperature event class for this temperature sensor" ::= { esPointConfigTempEntry 20 } --1.3.6.1.4.1.3052.17.2.2.1.1.20 espcTempVLowTemp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very Low temperature event threshold for this temperature sensor (in floating-point format)" ::= { esPointConfigTempEntry 21 } --1.3.6.1.4.1.3052.17.2.2.1.1.21 espcTempVLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very Low temperature event actions for this temperature sensor" ::= { esPointConfigTempEntry 22 } --1.3.6.1.4.1.3052.17.2.2.1.1.22 espcTempVLowTrapnum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Very Low temperature event trap number for this temperature sensor" ::= { esPointConfigTempEntry 23 } --1.3.6.1.4.1.3052.17.2.2.1.1.23 espcTempVLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very Low temperature event class for this temperature sensor" ::= { esPointConfigTempEntry 24 } --1.3.6.1.4.1.3052.17.2.2.1.1.24 esPointConfigCCTable OBJECT-TYPE SYNTAX SEQUENCE OF ESPointConfigCC MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes 3 basic attributes of contact closure points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number Points are referenced by a point config index. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the context of this contact closure point config table ; namely, which EventSensor and which sensor. " ::= { eventSensorPointConfig 2 } --1.3.6.1.4.1.3052.17.2.2.2 esPointConfigCCEntry OBJECT-TYPE SYNTAX ESPointConfigCC MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for EventSensor point config contact closure table" INDEX { espcCCIndexES, espcCCIndexPoint } ::= { esPointConfigCCTable 1 } --1.3.6.1.4.1.3052.17.2.2.2.1 espcCCIndexES OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "The part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config contact closure table; namely, which EventSensor and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors. " ::= { esPointConfigCCEntry 1 } --1.3.6.1.4.1.3052.17.2.2.2.1.1 espcCCIndexPoint OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "The part of the point index that delineates which sensor on the EventSensor. So this combined with espcCCIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of contact closure point configuration." ::= { esPointConfigCCEntry 2 } --1.3.6.1.4.1.3052.17.2.2.2.1.2 espcCCEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF enable for this contact closure" ::= { esPointConfigCCEntry 3 } --1.3.6.1.4.1.3052.17.2.2.2.1.3 espcCCName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Name for this contact closure" ::= { esPointConfigCCEntry 4 } --1.3.6.1.4.1.3052.17.2.2.2.1.4 espcCCEventState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Event state for this contact closure" ::= { esPointConfigCCEntry 5 } --1.3.6.1.4.1.3052.17.2.2.2.1.5 espcCCThreshold OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Event threshold (seconds) for this contact closure" ::= { esPointConfigCCEntry 6 } --1.3.6.1.4.1.3052.17.2.2.2.1.6 espcCCEventActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Event actions for this contact closure" ::= { esPointConfigCCEntry 7 } --1.3.6.1.4.1.3052.17.2.2.2.1.7 espcCCEventTrapnum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Event trap number for this contact closure" ::= { esPointConfigCCEntry 8 } --1.3.6.1.4.1.3052.17.2.2.2.1.8 espcCCEventClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Event class for this contact closure" ::= { esPointConfigCCEntry 9 } --1.3.6.1.4.1.3052.17.2.2.2.1.9 espcCCNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return-to-normal actions for this contact closure" ::= { esPointConfigCCEntry 10 } --1.3.6.1.4.1.3052.17.2.2.2.1.10 espcCCNormalTrapnum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Return-to-normal trap number for this contact closure" ::= { esPointConfigCCEntry 11 } --1.3.6.1.4.1.3052.17.2.2.2.1.11 espcCCNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return-to-normal class for this contact closure" ::= { esPointConfigCCEntry 12 } --1.3.6.1.4.1.3052.17.2.2.2.1.12 espcCCAlarmAlias OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Event alias for this contact closure" ::= { esPointConfigCCEntry 13 } --1.3.6.1.4.1.3052.17.2.2.2.1.13 espcCCNormalAlias OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return-to-normal alias for this contact closure" ::= { esPointConfigCCEntry 14 } --1.3.6.1.4.1.3052.17.2.2.2.1.14 espcCCNormalThreshold OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Event threshold (seconds) for this contact closure to return to normal" ::= { esPointConfigCCEntry 15 } --1.3.6.1.4.1.3052.17.2.2.2.1.15 esPointConfigHumidTable OBJECT-TYPE SYNTAX SEQUENCE OF ESPointConfigHumid MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes 3 basic attributes of humidity points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number (always 1 for humidity sensors) Points are referenced by a point config index. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the context of this humidity point config table ; namely, which EventSensor and which sensor. " ::= { eventSensorPointConfig 3 } --1.3.6.1.4.1.3052.17.2.2.3 esPointConfigHumidEntry OBJECT-TYPE SYNTAX ESPointConfigHumid MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for EventSensor point config humidity table" INDEX { espcHumidIndexES, espcHumidIndexPoint } ::= { esPointConfigHumidTable 1 } --1.3.6.1.4.1.3052.17.2.2.3.1 espcHumidIndexES OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "The part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config contact closure table; namely, which EventSensor and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors. " ::= { esPointConfigHumidEntry 1 } --1.3.6.1.4.1.3052.17.2.2.3.1.1 espcHumidIndexPoint OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "The part of the point index that delineates which sensor on the EventSensor. So this combined with espcHumidIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of contact closure point configuration." ::= { esPointConfigHumidEntry 2 } --1.3.6.1.4.1.3052.17.2.2.3.1.2 espcHumidEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF enable for this humidity sensor" ::= { esPointConfigHumidEntry 3 } --1.3.6.1.4.1.3052.17.2.2.3.1.3 espcHumidDeadband OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Deadband for this humidity sensor" ::= { esPointConfigHumidEntry 4 } --1.3.6.1.4.1.3052.17.2.2.3.1.4 espcHumidVHighHumid OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event threshold for this humidity sensor" ::= { esPointConfigHumidEntry 5 } --1.3.6.1.4.1.3052.17.2.2.3.1.5 espcHumidVHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event actions for this humidity sensor" ::= { esPointConfigHumidEntry 6 } --1.3.6.1.4.1.3052.17.2.2.3.1.6 espcHumidVHighTrapnum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event trap number for this humidity sensor" ::= { esPointConfigHumidEntry 7 } --1.3.6.1.4.1.3052.17.2.2.3.1.7 espcHumidVHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event class for this humidity sensor" ::= { esPointConfigHumidEntry 8 } --1.3.6.1.4.1.3052.17.2.2.3.1.8 espcHumidHighHumid OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "High event threshold for this humidity sensor" ::= { esPointConfigHumidEntry 9 } --1.3.6.1.4.1.3052.17.2.2.3.1.9 espcHumidHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event actions for this humidity sensor" ::= { esPointConfigHumidEntry 10 } --1.3.6.1.4.1.3052.17.2.2.3.1.10 espcHumidHighTrapnum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "High event trap number for this humidity sensor" ::= { esPointConfigHumidEntry 11 } --1.3.6.1.4.1.3052.17.2.2.3.1.11 espcHumidHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event class for this humidity sensor" ::= { esPointConfigHumidEntry 12 } --1.3.6.1.4.1.3052.17.2.2.3.1.12 espcHumidNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return-to-normal actions for this humidity sensor" ::= { esPointConfigHumidEntry 13 } --1.3.6.1.4.1.3052.17.2.2.3.1.13 espcHumidNormalTrapnum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Return-to-normal trap number for this humidity sensor" ::= { esPointConfigHumidEntry 14 } --1.3.6.1.4.1.3052.17.2.2.3.1.14 espcHumidNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return-to-normal class for this humidity sensor" ::= { esPointConfigHumidEntry 15 } --1.3.6.1.4.1.3052.17.2.2.3.1.15 espcHumidLowHumid OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Low event threshold for this humidity sensor" ::= { esPointConfigHumidEntry 16 } --1.3.6.1.4.1.3052.17.2.2.3.1.16 espcHumidLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event actions for this humidity sensor" ::= { esPointConfigHumidEntry 17 } --1.3.6.1.4.1.3052.17.2.2.3.1.17 espcHumidLowTrapnum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Low event trap number for this humidity sensor" ::= { esPointConfigHumidEntry 18 } --1.3.6.1.4.1.3052.17.2.2.3.1.18 espcHumidLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event class for this humidity sensor" ::= { esPointConfigHumidEntry 19 } --1.3.6.1.4.1.3052.17.2.2.3.1.19 espcHumidVLowHumid OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event threshold for this humidity sensor" ::= { esPointConfigHumidEntry 20 } --1.3.6.1.4.1.3052.17.2.2.3.1.20 espcHumidVLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event actions for this humidity sensor" ::= { esPointConfigHumidEntry 21 } --1.3.6.1.4.1.3052.17.2.2.3.1.21 espcHumidVLowTrapnum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event trap number for this humidity sensor" ::= { esPointConfigHumidEntry 22 } --1.3.6.1.4.1.3052.17.2.2.3.1.22 espcHumidVLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event class for this humidity sensor" ::= { esPointConfigHumidEntry 23 } --1.3.6.1.4.1.3052.17.2.2.3.1.23 esPointConfigAITable OBJECT-TYPE SYNTAX SEQUENCE OF ESPointConfigAnalogInput MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes 3 basic attributes of analog input points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number Points are referenced by a point config index. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the context of this analog input point config table ; namely, which EventSensor and which sensor. " ::= { eventSensorPointConfig 5 } --1.3.6.1.4.1.3052.17.2.2.5 esPointConfigAIEntry OBJECT-TYPE SYNTAX ESPointConfigAnalogInput MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for EventSensor point config analog input table" INDEX { espcHumidIndexES, espcHumidIndexPoint } ::= { esPointConfigAITable 1 } --1.3.6.1.4.1.3052.17.2.2.5.1 espcAIIndexES OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-only STATUS current DESCRIPTION "The part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config contact closure table; namely, which EventSensor and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors. " ::= { esPointConfigAIEntry 1 } --1.3.6.1.4.1.3052.17.2.2.5.1.1 espcAIIndexPoint OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "The part of the point index that delineates which sensor on the EventSensor. So this combined with espcAIIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of contact closure point configuration." ::= { esPointConfigAIEntry 2 } --1.3.6.1.4.1.3052.17.2.2.5.1.2 espcAIEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF for this analog input sensor" ::= { esPointConfigAIEntry 3 } --1.3.6.1.4.1.3052.17.2.2.5.1.3 espcAIPolarity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Polarity for this analog input sensor" ::= { esPointConfigAIEntry 4 } --1.3.6.1.4.1.3052.17.2.2.5.1.4 espcAIDeadband OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Deadband for this analog input sensor" ::= { esPointConfigAIEntry 5 } --1.3.6.1.4.1.3052.17.2.2.5.1.5 espcAIVhighValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event threshold (decivolts or tenths of milliamps) for this analog input sensor" ::= { esPointConfigAIEntry 6 } --1.3.6.1.4.1.3052.17.2.2.5.1.6 espcAIVhighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event actions for this analog input sensor" ::= { esPointConfigAIEntry 7 } --1.3.6.1.4.1.3052.17.2.2.5.1.7 espcAIVhighTrapnum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event trap number for this analog input sensor" ::= { esPointConfigAIEntry 8 } --1.3.6.1.4.1.3052.17.2.2.5.1.8 espcAIVhighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event class for this analog input sensor" ::= { esPointConfigAIEntry 9 } --1.3.6.1.4.1.3052.17.2.2.5.1.9 espcAIHighValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "High event threshold (decivolts or tenths of milliamps) for this analog input sensor" ::= { esPointConfigAIEntry 10 } --1.3.6.1.4.1.3052.17.2.2.5.1.10 espcAIHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event actions for this analog input sensor" ::= { esPointConfigAIEntry 11 } --1.3.6.1.4.1.3052.17.2.2.5.1.11 espcAIHighTrapnum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "High event trap number for this analog input sensor" ::= { esPointConfigAIEntry 12 } --1.3.6.1.4.1.3052.17.2.2.5.1.12 espcAIHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event class for this analog input sensor" ::= { esPointConfigAIEntry 13 } --1.3.6.1.4.1.3052.17.2.2.5.1.13 espcAINormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return-to-normal actions for this analog input sensor" ::= { esPointConfigAIEntry 14 } --1.3.6.1.4.1.3052.17.2.2.5.1.14 espcAINormalTrapnum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Return-to-normal trap number for this analog input sensor" ::= { esPointConfigAIEntry 15 } --1.3.6.1.4.1.3052.17.2.2.5.1.15 espcAINormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return-to-normal class for this analog input sensor" ::= { esPointConfigAIEntry 16 } --1.3.6.1.4.1.3052.17.2.2.5.1.16 espcAILowValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Low event threshold (decivolts or tenths of milliamps) for this analog input sensor" ::= { esPointConfigAIEntry 17 } --1.3.6.1.4.1.3052.17.2.2.5.1.17 espcAILowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event actions for this analog input sensor" ::= { esPointConfigAIEntry 18 } --1.3.6.1.4.1.3052.17.2.2.5.1.18 espcAILowTrapnum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Low event trap number for this analog input sensor" ::= { esPointConfigAIEntry 19 } --1.3.6.1.4.1.3052.17.2.2.5.1.19 espcAILowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event class for this analog input sensor" ::= { esPointConfigAIEntry 20 } --1.3.6.1.4.1.3052.17.2.2.5.1.20 espcAIVlowValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event threshold (decivolts or tenths of milliamps) for this analog input sensor" ::= { esPointConfigAIEntry 21 } --1.3.6.1.4.1.3052.17.2.2.5.1.21 espcAIVlowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event actions for this analog input sensor" ::= { esPointConfigAIEntry 22 } --1.3.6.1.4.1.3052.17.2.2.5.1.22 espcAIVlowTrapnum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event actions for this analog input sensor" ::= { esPointConfigAIEntry 23 } --1.3.6.1.4.1.3052.17.2.2.5.1.23 espcAIVlowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event class for this analog input sensor" ::= { esPointConfigAIEntry 24 } --1.3.6.1.4.1.3052.17.2.2.5.1.24 espcAIConvUnitName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Converstion unit name for this analog input sensor" ::= { esPointConfigAIEntry 25 } --1.3.6.1.4.1.3052.17.2.2.5.1.25 espcAIConvHighValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Conversion high value for this analog input sensor" ::= { esPointConfigAIEntry 26 } --1.3.6.1.4.1.3052.17.2.2.5.1.26 espcAIConvHighUnit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Conversion high unit value for this analog input sensor" ::= { esPointConfigAIEntry 27 } --1.3.6.1.4.1.3052.17.2.2.5.1.27 espcAIConvHighSign OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Conversion high sign for this analog input sensor" ::= { esPointConfigAIEntry 28 } --1.3.6.1.4.1.3052.17.2.2.5.1.28 espcAIConvLowValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Conversion low value for this analog input sensor" ::= { esPointConfigAIEntry 29 } --1.3.6.1.4.1.3052.17.2.2.5.1.29 espcAIConvLowUnit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Conversion unit low unit value for this analog input sensor" ::= { esPointConfigAIEntry 30 } --1.3.6.1.4.1.3052.17.2.2.5.1.30 espcAIConvLowSign OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Conversion low sign for this analog input sensor" ::= { esPointConfigAIEntry 31 } --1.3.6.1.4.1.3052.17.2.2.5.1.31 --*************************************************************************************** --Serial Port Section 2.3 --*************************************************************************************** numberPorts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of RS-232 ports found. Range: 2 or 4" ::= { serialPorts 1 } --1.3.6.1.4.1.3052.17.2.3.1 portConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF PortConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port config table" ::= { serialPorts 2 } --1.3.6.1.4.1.3052.17.2.3.2 portConfigEntry OBJECT-TYPE SYNTAX PortConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port config entry" INDEX { portConfigIndex } ::= { portConfigTable 1 } --1.3.6.1.4.1.3052.17.2.3.2.1 portConfigIndex OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for ports" ::= { portConfigEntry 1 } --1.3.6.1.4.1.3052.17.2.3.2.1.1 portConfigBaud OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Baud rate, 19200, 9600, etc." ::= { portConfigEntry 2 } --1.3.6.1.4.1.3052.17.2.3.2.1.2 portConfigDataFormat OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Value representing word length, parity, and stop bits: 0=8N1, 1=7E1, 2=7O1, 3=7N1, 4=8O2" ::= { portConfigEntry 3 } --1.3.6.1.4.1.3052.17.2.3.2.1.3 portConfigStripPtOutputLfs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Strip passthrough LFs sent to device on this port: 1=yes, 0=no." ::= { portConfigEntry 4 } --1.3.6.1.4.1.3052.17.2.3.2.1.4 portConfigStripPtInputLfs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Strip passthrough LFs received from device on this port: 1=yes, 0=no." ::= { portConfigEntry 5 } --1.3.6.1.4.1.3052.17.2.3.2.1.5 portConfigMaskEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "1=Use the character mask on this port. 0=Do not use the mask. When the mask is enabled, the following ASCII characters are ignored on the port: 0, 1, 4-9, 11, 12, 14-31, 128-255. When the mask is disabled, all characters are accepted on the port." ::= { portConfigEntry 7 } --1.3.6.1.4.1.3052.17.2.3.2.1.7 portConfigDAEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "1=Enable the Data Alarm Evaluator for data on this port. 0=Do not evaluate data on this port." ::= { portConfigEntry 8 } --1.3.6.1.4.1.3052.17.2.3.2.1.8 portConfigStoreAlarmsDPT OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF: store alarms received during passthrough" ::= { portConfigEntry 9 } --1.3.6.1.4.1.3052.17.2.3.2.1.9 portConfigRecordTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Timeout after last unterminated data received upon which data collected so far is stored as a record." ::= { portConfigEntry 10 } --1.3.6.1.4.1.3052.17.2.3.2.1.10 portConfigDataType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "How the port interprets incoming data: ASCII/BINARY" ::= { portConfigEntry 11 } --1.3.6.1.4.1.3052.17.2.3.2.1.11 portConfigEtxToCRLF OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF whether the port translates incoming ETX to CRLF" ::= { portConfigEntry 12 } --1.3.6.1.4.1.3052.17.2.3.2.1.12 portConfigMLREnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF Whether Multiline Records are collected on this port." ::= { portConfigEntry 13 } --1.3.6.1.4.1.3052.17.2.3.2.1.13 portConfigMLRStartField1Pos OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Position of MLR start field 1" ::= { portConfigEntry 14 } --1.3.6.1.4.1.3052.17.2.3.2.1.14 portConfigMLRStartField1Text OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Text to match MLR start field 1" ::= { portConfigEntry 15 } --1.3.6.1.4.1.3052.17.2.3.2.1.15 portConfigMLRStartField2Pos OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Position of MLR start field 2" ::= { portConfigEntry 16 } --1.3.6.1.4.1.3052.17.2.3.2.1.16 portConfigMLRStartField2Text OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Text to match MLR start field 2" ::= { portConfigEntry 17 } --1.3.6.1.4.1.3052.17.2.3.2.1.17 portConfigMLRNumLinesBefore OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of lines before the starting line which should be included in the MLR" ::= { portConfigEntry 18 } --1.3.6.1.4.1.3052.17.2.3.2.1.18 portConfigMLREndDetection OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "How the MLR parser determines what ends an MLR: by FORMULA, number of lines received so far (COUNT), or number of blank lines received so far (BLANKS)" ::= { portConfigEntry 19 } --1.3.6.1.4.1.3052.17.2.3.2.1.19 portConfigMLRLineCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of lines in the MLR (used by the end detection mode)" ::= { portConfigEntry 20 } --1.3.6.1.4.1.3052.17.2.3.2.1.20 portConfigMLREndField1Pos OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Position of MLR end field 1" ::= { portConfigEntry 21 } --1.3.6.1.4.1.3052.17.2.3.2.1.21 portConfigMLREndField1Text OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Text to match MLR end field 1" ::= { portConfigEntry 22 } --1.3.6.1.4.1.3052.17.2.3.2.1.22 portConfigMLREndField2Pos OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Position of MLR end field 2" ::= { portConfigEntry 23 } --1.3.6.1.4.1.3052.17.2.3.2.1.23 portConfigMLREndField2Text OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Text to match MLR end field 2" ::= { portConfigEntry 24 } --1.3.6.1.4.1.3052.17.2.3.2.1.24 portConfigMLRUseComplexRules OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF MLR parser uses complex rules (field possitions/ formulas, etc.)" ::= { portConfigEntry 25 } --1.3.6.1.4.1.3052.17.2.3.2.1.25 portConfigBufferPT OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF records received during passthrough mode are buffered/stored in the database" ::= { portConfigEntry 26 } --1.3.6.1.4.1.3052.17.2.3.2.1.26 portConfigId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The text identifer for the port" ::= { portConfigEntry 27 } --1.3.6.1.4.1.3052.17.2.3.2.1.27 --*************************************************************************************** --Network Section 2.4 --*************************************************************************************** eth1Mode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Mode of the Ethernet1 interface: STATIC,DHCP,VLAN" ::= { ethernet1 1 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.1 eth1Address OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 IP address" ::= { ethernet1 2 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.2 eth1SubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 subnet mask" ::= { ethernet1 3 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.3 eth1Router OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 router" ::= { ethernet1 4 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.4 -- Ethernet1 VLAN1 eth1VLAN1ID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN1 ID" ::= { eth1VLAN1 1 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.1.1 eth1VLAN1Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN1 priority" ::= { eth1VLAN1 2 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.1.2 eth1VLAN1Address OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN1 IP address" ::= { eth1VLAN1 3 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.1.3 eth1VLAN1SubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN1 subnet mask" ::= { eth1VLAN1 4 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.1.4 eth1VLAN1Router OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN1 router" ::= { eth1VLAN1 5 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.1.5 -- Ethernet1 VLAN2 eth1VLAN2ID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN2 ID" ::= { eth1VLAN2 1 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.2.1 eth1VLAN2Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN2 priority" ::= { eth1VLAN2 2 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.2.2 eth1VLAN2Address OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN2 IP address" ::= { eth1VLAN2 3 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.2.3 eth1VLAN2SubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN2 subnet mask" ::= { eth1VLAN2 4 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.2.4 eth1VLAN2Router OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN2 router" ::= { eth1VLAN2 5 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.2.5 -- Ethernet1 VLAN3 eth1VLAN3ID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN3 ID" ::= { eth1VLAN3 1 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.3.1 eth1VLAN3Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN3 priority" ::= { eth1VLAN3 2 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.3.2 eth1VLAN3Address OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN3 IP address" ::= { eth1VLAN3 3 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.3.3 eth1VLAN3SubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN3 subnet mask" ::= { eth1VLAN3 4 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.3.4 eth1VLAN3Router OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN3 router" ::= { eth1VLAN3 5 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.3.5 -- Ethernet1 VLAN4 eth1VLAN4ID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN4 ID" ::= { eth1VLAN4 1 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.4.1 eth1VLAN4Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN4 priority" ::= { eth1VLAN4 2 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.4.2 eth1VLAN4Address OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN4 IP address" ::= { eth1VLAN4 3 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.4.3 eth1VLAN4SubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN4 subnet mask" ::= { eth1VLAN4 4 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.4.4 eth1VLAN4Router OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN4 router" ::= { eth1VLAN4 5 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.4.5 -- Ethernet1 VLAN5 eth1VLAN5ID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN5 ID" ::= { eth1VLAN5 1 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.5.1 eth1VLAN5Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN5 priority" ::= { eth1VLAN5 2 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.5.2 eth1VLAN5Address OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN5 IP address" ::= { eth1VLAN5 3 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.5.3 eth1VLAN5SubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN5 subnet mask" ::= { eth1VLAN5 4 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.5.4 eth1VLAN5Router OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN5 router" ::= { eth1VLAN5 5 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.5.5 -- Ethernet1 VLAN6 eth1VLAN6ID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN6 ID" ::= { eth1VLAN6 1 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.6.1 eth1VLAN6Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN6 priority" ::= { eth1VLAN6 2 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.6.2 eth1VLAN6Address OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN6 IP address" ::= { eth1VLAN6 3 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.6.3 eth1VLAN6SubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN6 subnet mask" ::= { eth1VLAN6 4 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.6.4 eth1VLAN6Router OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet1 VLAN6 router" ::= { eth1VLAN6 5 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.5.6.5 eth1MAC OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet1 MAC" ::= { ethernet1 6 } --1.3.6.1.4.1.3052.17.2.4.1.1.1.6 eth2Mode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Mode of the Ethernet2 interface: STATIC,DHCP,VLAN" ::= { ethernet2 1 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.1 eth2Address OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 IP address" ::= { ethernet2 2 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.2 eth2SubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 subnet mask" ::= { ethernet2 3 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.3 eth2Router OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 router" ::= { ethernet2 4 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.4 -- Ethernet2 VLAN1 eth2VLAN1ID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN1 ID" ::= { eth2VLAN1 1 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.1.1 eth2VLAN1Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN1 priority" ::= { eth2VLAN1 2 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.1.2 eth2VLAN1Address OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN1 IP address" ::= { eth2VLAN1 3 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.1.3 eth2VLAN1SubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN1 subnet mask" ::= { eth2VLAN1 4 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.1.4 eth2VLAN1Router OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN1 router" ::= { eth2VLAN1 5 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.1.5 -- Ethernet2 VLAN2 eth2VLAN2ID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN2 ID" ::= { eth2VLAN2 1 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.2.1 eth2VLAN2Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN2 priority" ::= { eth2VLAN2 2 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.2.2 eth2VLAN2Address OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN2 IP address" ::= { eth2VLAN2 3 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.2.3 eth2VLAN2SubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN2 subnet mask" ::= { eth2VLAN2 4 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.2.4 eth2VLAN2Router OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN2 router" ::= { eth2VLAN2 5 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.2.5 -- Ethernet2 VLAN3 eth2VLAN3ID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN3 ID" ::= { eth2VLAN3 1 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.3.1 eth2VLAN3Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN3 priority" ::= { eth2VLAN3 2 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.3.2 eth2VLAN3Address OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN3 IP address" ::= { eth2VLAN3 3 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.3.3 eth2VLAN3SubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN3 subnet mask" ::= { eth2VLAN3 4 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.3.4 eth2VLAN3Router OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN3 router" ::= { eth2VLAN3 5 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.3.5 -- Ethernet2 VLAN4 eth2VLAN4ID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN4 ID" ::= { eth2VLAN4 1 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.4.1 eth2VLAN4Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN4 priority" ::= { eth2VLAN4 2 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.4.2 eth2VLAN4Address OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN4 IP address" ::= { eth2VLAN4 3 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.4.3 eth2VLAN4SubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN4 subnet mask" ::= { eth2VLAN4 4 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.4.4 eth2VLAN4Router OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN4 router" ::= { eth2VLAN4 5 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.4.5 -- Ethernet2 VLAN5 eth2VLAN5ID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN5 ID" ::= { eth2VLAN5 1 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.5.1 eth2VLAN5Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN5 priority" ::= { eth2VLAN5 2 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.5.2 eth2VLAN5Address OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN5 IP address" ::= { eth2VLAN5 3 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.5.3 eth2VLAN5SubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN5 subnet mask" ::= { eth2VLAN5 4 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.5.4 eth2VLAN5Router OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN5 router" ::= { eth2VLAN5 5 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.5.5 -- Ethernet2 VLAN6 eth2VLAN6ID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN6 ID" ::= { eth2VLAN6 1 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.6.1 eth2VLAN6Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN6 priority" ::= { eth2VLAN6 2 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.6.2 eth2VLAN6Address OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN6 IP address" ::= { eth2VLAN6 3 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.6.3 eth2VLAN6SubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN6 subnet mask" ::= { eth2VLAN6 4 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.6.4 eth2VLAN6Router OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ethernet2 VLAN6 router" ::= { eth2VLAN6 5 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.5.6.5 eth2MAC OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet2 MAC" ::= { ethernet2 6 } --1.3.6.1.4.1.3052.17.2.4.1.1.2.6 defaultRouter OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The default router/gateway" ::= { network 2 } --1.3.6.1.4.1.3052.17.2.4.2 -- DNS dnsTable OBJECT-TYPE SYNTAX SEQUENCE OF DNSConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "DNS server address table" ::= { network 3 } --1.3.6.1.4.1.3052.17.2.4.3 dnsEntry OBJECT-TYPE SYNTAX DNSConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "DNS server address entry" INDEX { dnsIndex } ::= { dnsTable 1 } --1.3.6.1.4.1.3052.17.2.4.3.1 dnsIndex OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for DNS server address" ::= { dnsEntry 1 } --1.3.6.1.4.1.3052.17.2.4.3.1.1 dnsAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "DNS server address" ::= { dnsEntry 2 } --1.3.6.1.4.1.3052.17.2.4.3.1.2 hostname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The hostname of the unit" ::= { network 4 } --1.3.6.1.4.1.3052.17.2.4.4 hostTable OBJECT-TYPE SYNTAX SEQUENCE OF HostConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Static host table" ::= { network 5 } --1.3.6.1.4.1.3052.17.2.4.5 hostEntry OBJECT-TYPE SYNTAX HostConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Static host entry" INDEX { hostIndex } ::= { hostTable 1 } --1.3.6.1.4.1.3052.17.2.4.5.1 hostIndex OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for static host" ::= { hostEntry 1 } --1.3.6.1.4.1.3052.17.2.4.5.1.1 hostDeclaration OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Static host declaration string (i.e. 'address hostname')" ::= { hostEntry 2 } --1.3.6.1.4.1.3052.17.2.4.5.1.2 -- Network Command Processor ncpDuplex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "For network command processor: 1=Input characters are echoed; 0=no echo." ::= { network 6 } --1.3.6.1.4.1.3052.17.2.4.6 ncpTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Network command processor inactivity timeout" ::= { network 7 } --1.3.6.1.4.1.3052.17.2.4.7 -- SNMP snmpAgentEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF for snmp agent" ::= { snmp 1 } --1.3.6.1.4.1.3052.17.2.4.8.1 snmpNtfnAttempts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum of times the unit attempts to send a notification (trap/inform) in 1 cycle" ::= { snmpNotificationTx 1 } --1.3.6.1.4.1.3052.17.2.4.8.7.1 snmpNtfnTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of seconds between retries of sending a notification" ::= { snmpNotificationTx 2 } --1.3.6.1.4.1.3052.17.2.4.8.7.2 snmpNtfnCycles OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of times the unit attempts a group of attempts to send a notification (a cycle)" ::= { snmpNotificationTx 3 } --1.3.6.1.4.1.3052.17.2.4.8.7.3 snmpNtfnSnooze OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Minutes between cycles" ::= { snmpNotificationTx 4 } --1.3.6.1.4.1.3052.17.2.4.8.7.4 -- SNMP proxy snmpProxyTable OBJECT-TYPE SYNTAX SEQUENCE OF SNMPProxyTable MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of SNMP proxy entries" ::= { snmpProxy 1 } --1.3.6.1.4.1.3052.17.2.4.8.8.1 snmpProxyEntry OBJECT-TYPE SYNTAX SNMPProxyTable MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for SNMP proxy table" INDEX { snmpProxyIndex } ::= { snmpProxyTable 1 } --1.3.6.1.4.1.3052.17.2.4.8.8.1.1 snmpProxyIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for SNMP proxy table" ::= { snmpProxyEntry 1 } --1.3.6.1.4.1.3052.17.2.4.8.8.1.1.1 snmpProxyOIDBranch OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The OID branch to trigger the proxy function. This should cover the device to proxy." ::= { snmpProxyEntry 2 } --1.3.6.1.4.1.3052.17.2.4.8.8.1.1.2 snmpProxyIP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of the device to proxy." ::= { snmpProxyEntry 3 } --1.3.6.1.4.1.3052.17.2.4.8.8.1.1.3 snmpProxyPort OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The UDP port on which the device to proxy listens." ::= { snmpProxyEntry 4 } --1.3.6.1.4.1.3052.17.2.4.8.8.1.1.4 -- SNMP Poll snmpPMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Mode of poll operation: OFF or POLL ONLY (just make the results available to view)." ::= { snmpPoll 1 } --1.3.6.1.4.1.3052.17.2.4.8.9.1 snmpPRequestTable OBJECT-TYPE SYNTAX SEQUENCE OF SNMPPollRequestConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of SNMP Poll requests." ::= { snmpPoll 4 } --1.3.6.1.4.1.3052.17.2.4.8.9.4 snmpPRequestEntry OBJECT-TYPE SYNTAX SNMPPollRequestConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table pf SNMP Poll requests." INDEX { snmpPRequestIndex } ::= { snmpPRequestTable 1 } --1.3.6.1.4.1.3052.17.2.4.8.9.4.1 snmpPRequestIndex OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of SNMP Poll requests." ::= { snmpPRequestEntry 1 } --1.3.6.1.4.1.3052.17.2.4.8.9.4.1.1 snmpPRequestDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A description for this single telemetry request; no functional effect." ::= { snmpPRequestEntry 2 } --1.3.6.1.4.1.3052.17.2.4.8.9.4.1.2 snmpPRequestAgent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Agent IP address or hostname for this single telemetry request." ::= { snmpPRequestEntry 3 } --1.3.6.1.4.1.3052.17.2.4.8.9.4.1.3 snmpPRequestReadcom OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP read community for this single telemetry request." ::= { snmpPRequestEntry 4 } --1.3.6.1.4.1.3052.17.2.4.8.9.4.1.4 snmpPRequestOID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP object identifier for this single telemetry request." ::= { snmpPRequestEntry 5 } --1.3.6.1.4.1.3052.17.2.4.8.9.4.1.5 snmpPRequestPeriod OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "How many seconds between periodic SNMP polls of this single telemetry request." ::= { snmpPRequestEntry 6 } --1.3.6.1.4.1.3052.17.2.4.8.9.4.1.6 snmpPRequestResultStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the last attempt for this telemetry request." ::= { snmpPRequestEntry 10 } --1.3.6.1.4.1.3052.17.2.4.8.9.4.1.10 snmpPRequestResultValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The telemetry value if the last request was successful." ::= { snmpPRequestEntry 11 } --1.3.6.1.4.1.3052.17.2.4.8.9.4.1.11 snmpPRequestResultTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The timestamp of the last telemetry request." ::= { snmpPRequestEntry 12 } --1.3.6.1.4.1.3052.17.2.4.8.9.4.1.12 snmpPRequestResultType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the telemetry as reported by the agent." ::= { snmpPRequestEntry 13 } --1.3.6.1.4.1.3052.17.2.4.8.9.4.1.13 -- FTP ftpPushEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable FTP push for REGULAR (protocol: FTP) or SECURE (protocol: SFTP) operation, or disable it (OFF)" ::= { ftpPush 1 } --1.3.6.1.4.1.3052.17.2.4.9.1 ftpPushServer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "FTP server to which data should be pushed" ::= { ftpPush 2 } --1.3.6.1.4.1.3052.17.2.4.9.2 ftpPushAccount OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "FTP push account" ::= { ftpPush 5 } --1.3.6.1.4.1.3052.17.2.4.9.5 ftpPushDirectory OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "FTP push directory" ::= { ftpPush 6 } --1.3.6.1.4.1.3052.17.2.4.9.6 ftpPushperiod OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Minutes between pushes" ::= { ftpPush 7 } --1.3.6.1.4.1.3052.17.2.4.9.7 ftpPushPushFileTable OBJECT-TYPE SYNTAX SEQUENCE OF FTPPushPushFileConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of files to push" ::= { ftpPush 8 } --1.3.6.1.4.1.3052.17.2.4.9.8 ftpPushPushFileEntry OBJECT-TYPE SYNTAX FTPPushPushFileConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of files to push" INDEX { ftpPushPushFileIndex } ::= { ftpPushPushFileTable 1 } --1.3.6.1.4.1.3052.17.2.4.9.8.1 ftpPushPushFileIndex OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of files to push" ::= { ftpPushPushFileEntry 1 } --1.3.6.1.4.1.3052.17.2.4.9.8.1.1 ftpPushPushFile OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF push this local FILEx" ::= { ftpPushPushFileEntry 2 } --1.3.6.1.4.1.3052.17.2.4.9.8.1.2 ftpPushPushAudit OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF push the audit log" ::= { ftpPush 9 } --1.3.6.1.4.1.3052.17.2.4.9.9 ftpPushPushAlarms OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF push the alarms/events file" ::= { ftpPush 10 } --1.3.6.1.4.1.3052.17.2.4.9.10 ftpPushRemoteFileTable OBJECT-TYPE SYNTAX SEQUENCE OF FTPPushRemoteFileConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of remote names of files to push" ::= { ftpPush 11 } --1.3.6.1.4.1.3052.17.2.4.9.11 ftpPushRemoteFileEntry OBJECT-TYPE SYNTAX FTPPushRemoteFileConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of remote names of files to push" INDEX { ftpPushRemoteFileIndex } ::= { ftpPushRemoteFileTable 1 } --1.3.6.1.4.1.3052.17.2.4.9.11.1 ftpPushRemoteFileIndex OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of remote names of files to push" ::= { ftpPushRemoteFileEntry 1 } --1.3.6.1.4.1.3052.17.2.4.9.11.1 ftpPushRemoteFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "remote name of pushed FILEx (name on server)" ::= { ftpPushRemoteFileEntry 2 } --1.3.6.1.4.1.3052.17.2.4.9.11.2 ftpPushRemoteAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Filename on server for alarms" ::= { ftpPush 12 } --1.3.6.1.4.1.3052.17.2.4.9.12 ftpPushPassive OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF use ftp passive mode" ::= { ftpPush 13 } --1.3.6.1.4.1.3052.17.2.4.9.13 ftpPushIncludeDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF include the date in the name of the pushed file" ::= { ftpPush 14 } --1.3.6.1.4.1.3052.17.2.4.9.14 ftpPushIncludeTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF include the time in the name of the pushed file" ::= { ftpPush 15 } --1.3.6.1.4.1.3052.17.2.4.9.15 ftpPushIncludeSeq OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF include a sequence number in the name of the pushed file" ::= { ftpPush 16 } --1.3.6.1.4.1.3052.17.2.4.9.16 -- Routing ethRoutingEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF unit routes IP traffic from Ethernet to PPP/Wireless" ::= { routing 2 } --1.3.6.1.4.1.3052.17.2.4.11.2 ethRoutingNATEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF unit applies NAT on routed IP frames egressing the unit on its PPP interface" ::= { routing 3 } --1.3.6.1.4.1.3052.17.2.4.11.3 -- IP Restrictions ipRestrictionTable OBJECT-TYPE SYNTAX SEQUENCE OF IPRestrictionConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of IP restrictions" ::= { ipRestriction 1 } --1.3.6.1.4.1.3052.17.2.4.12.1.1 ipRestrictionEntry OBJECT-TYPE SYNTAX IPRestrictionConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of IP restrictions" INDEX { ipRestrictionIndex } ::= { ipRestrictionTable 1 } --1.3.6.1.4.1.3052.17.2.4.12.1.1 ipRestrictionIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of IP restrictions" ::= { ipRestrictionEntry 1 } --1.3.6.1.4.1.3052.17.2.4.12.1.1.1.1 ipRestrictionEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF enable this IP restriction" ::= { ipRestrictionEntry 2 } --1.3.6.1.4.1.3052.17.2.4.12.1.1.1.2 ipRestrictionMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP restriction mask" ::= { ipRestrictionEntry 3 } --1.3.6.1.4.1.3052.17.2.4.12.1.1.1.3 -- RTS rtsFileTable OBJECT-TYPE SYNTAX SEQUENCE OF RTSFileConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of RTS files" ::= { rts 1 } --1.3.6.1.4.1.3052.17.2.4.13.1 rtsFileEntry OBJECT-TYPE SYNTAX RTSFileConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of RTS files" INDEX { rtsFileIndex } ::= { rtsFileTable 1 } --1.3.6.1.4.1.3052.17.2.4.13.1 rtsFileIndex OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of RTS files" ::= { rtsFileEntry 1 } --1.3.6.1.4.1.3052.17.2.4.13.1.1.1 rtsFileMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "RTS mode (OFF,LISTEN,PUSH) for FILEx" ::= { rtsFileEntry 2 } --1.3.6.1.4.1.3052.17.2.4.13.1.1.2 rtsFileShowAnswer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Show answer string upon RTS connect for FILEx" ::= { rtsFileEntry 3 } --1.3.6.1.4.1.3052.17.2.4.13.1.1.3 rtsFileReqXON OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF require XON to start flow for FILEx" ::= { rtsFileEntry 4 } --1.3.6.1.4.1.3052.17.2.4.13.1.1.4 rtsFileTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Idle connection close timer (0 means no timeout) for FILEx" ::= { rtsFileEntry 5 } --1.3.6.1.4.1.3052.17.2.4.13.1.1.5 rtsFileEmptyClose OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF close the socket when FILEx is empty" ::= { rtsFileEntry 6 } --1.3.6.1.4.1.3052.17.2.4.13.1.1.6 rtsFilePushHost OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Host to which FILEx should be pushed via RTS" ::= { rtsFileEntry 7 } --1.3.6.1.4.1.3052.17.2.4.13.1.1.7 rtsFilePushPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "TCP port to which FILEx should be pushed via RTS" ::= { rtsFileEntry 8 } --1.3.6.1.4.1.3052.17.2.4.13.1.1.8 rtsFilePushRetryTimer OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Retry timer (seconds) for retrying failed RTS push connect attempts" ::= { rtsFileEntry 9 } --1.3.6.1.4.1.3052.17.2.4.13.1.1.9 -- RTS Alarms rtsAlarmsMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "RTS mode (OFF,LISTEN,PUSH) for alarms file" ::= { rtsAlarms 1 } --1.3.6.1.4.1.3052.17.2.4.13.2.1 rtsAlarmsShowAnswer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Show answer string upon RTS connect for alarms file" ::= { rtsAlarms 2 } --1.3.6.1.4.1.3052.17.2.4.13.2.2 rtsAlarmsReqXON OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF require XON to start flow for alarms file" ::= { rtsAlarms 3 } --1.3.6.1.4.1.3052.17.2.4.13.2.3 rtsAlarmsTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Idle connection close timer (0 means no timeout) for alarms file" ::= { rtsAlarms 4 } --1.3.6.1.4.1.3052.17.2.4.13.2.4 rtsAlarmsEmptyClose OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF close the socket when this file is empty for alarms file" ::= { rtsAlarms 5 } --1.3.6.1.4.1.3052.17.2.4.13.2.5 rtsAlarmsPushHost OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Host to which alarms file should be pushed via RTS" ::= { rtsAlarms 6 } --1.3.6.1.4.1.3052.17.2.4.13.2.6 rtsAlarmsPushPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "TCP port to which alarms file should be pushed via RTS" ::= { rtsAlarms 7 } --1.3.6.1.4.1.3052.17.2.4.13.2.7 rtsAlarmsPushRetryTimer OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Retry timer (seconds) for retrying failed RTS push connect attempts" ::= { rtsAlarms 8 } --1.3.6.1.4.1.3052.17.2.4.13.2.8 -- Traps trapIncludeDateTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF include date and time in stock trap message" ::= { trapInclude 1 } --1.3.6.1.4.1.3052.17.2.4.14.1.1 trapIncludeSiteName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF include site name in stock trap message" ::= { trapInclude 2 } --1.3.6.1.4.1.3052.17.2.4.14.1.2 trapIncludeSensorID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF include sensor ID in stock trap message" ::= { trapInclude 3 } --1.3.6.1.4.1.3052.17.2.4.14.1.3 trapIncludeUDName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF include user defined name in stock trap message" ::= { trapInclude 4 } --1.3.6.1.4.1.3052.17.2.4.14.1.4 trapIncludeUDState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF include user defined state in stock trap message" ::= { trapInclude 5 } --1.3.6.1.4.1.3052.17.2.4.14.1.5 trapIncludeSourceAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF include source IP address in stock trap message" ::= { trapInclude 6 } --1.3.6.1.4.1.3052.17.2.4.14.1.6 trapAuthFailEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF enable trap sent upon SNMP authentication failure" ::= { trap 2 } --1.3.6.1.4.1.3052.17.2.4.14.2 -- Wireless wirelessMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Wireless mode (OFF,PERMANENT-EDGE)" ::= { wireless 1 } --1.3.6.1.4.1.3052.17.2.4.16.1 wirelessAPN OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Wireless access point name" ::= { wireless 2 } --1.3.6.1.4.1.3052.17.2.4.16.2 wirelessIdleTimeout OBJECT-TYPE SYNTAX Integer32 (3..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Wireless idle timeout" ::= { wireless 3 } --1.3.6.1.4.1.3052.17.2.4.16.3 wirelessPIN OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Wireless modem SIM PIN" ::= { wireless 5 } --1.3.6.1.4.1.3052.17.2.4.16.5 wirelessDRE OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Default route enable for wireless network interface. When this is ON, the wireless link, if up, becomes the default route, overriding the default route setting (defaultRouter object). When OFF, the default route setting controls the default route and the wireless link does not become the default route." ::= { wireless 9 } --1.3.6.1.4.1.3052.17.2.4.16.9 -- Email emailServer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "SMTP server to which the unit sends email" ::= { email 1 } --1.3.6.1.4.1.3052.17.2.4.17.1 emailDomain OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Domain to use in recipient address" ::= { email 2 } --1.3.6.1.4.1.3052.17.2.4.17.2 emailAuthEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF enable SMTP authentication" ::= { email 3 } --1.3.6.1.4.1.3052.17.2.4.17.3 -- Advanced network config arpFilter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "ARP filter code" ::= { netAdvanced 1 } --1.3.6.1.4.1.3052.17.2.4.18.1 -- Web interface webEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF for the web interface" ::= { web 1 } --1.3.6.1.4.1.3052.17.2.4.19.1 webPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "TCP port on which web interface listens" ::= { web 2 } --1.3.6.1.4.1.3052.17.2.4.19.2 webTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Web interface session timeout (seconds)" ::= { web 3 } --1.3.6.1.4.1.3052.17.2.4.19.3 --*************************************************************************************** --Time Section 2.8 --*************************************************************************************** clock OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Text string for date and time; e.g. 'SUN 01/02/98 12:34:27'. When setting this object, only the date and time are required; the unit will ignore a specified day of week because it is calculated from the date and time. When this object is included in a notification as a varbind, it represents the time that the triggering event occurred." ::= { time 1 } --1.3.6.1.4.1.3052.17.2.8.1 --*************************************************************************************** --Console Section 2.10 --*************************************************************************************** consoleDuplex OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF characters echoed on telnet command session" ::= { console 1 } --1.3.6.1.4.1.3052.17.2.10.1 consoleTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Minutes of inactivity after which telnet command session is terminated" ::= { console 2 } --1.3.6.1.4.1.3052.17.2.10.2 consoleConfirm OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF Prompt to confirm certain actions" ::= { console 7 } --1.3.6.1.4.1.3052.17.2.10.7 --*************************************************************************************** --Core Security Section 2.11.1 --*************************************************************************************** scShowPasswordPrompt OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF show password prompt upon login" ::= { secCore 1 } --1.3.6.1.4.1.3052.17.2.11.1.1 scConsoleLoginRequired OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF login required upon connecting via console" ::= { secCore 2 } --1.3.6.1.4.1.3052.17.2.11.1.2 scModemLoginRequired OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF login required upon connecting via modem" ::= { secCore 3 } --1.3.6.1.4.1.3052.17.2.11.1.3 scTelnetLoginRequired OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF login required upon connecting via Telnet" ::= { secCore 4 } --1.3.6.1.4.1.3052.17.2.11.1.4 scTelnetPTLoginRequired OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF login required upon connecting via Telnet to pass- through ports (TCP ports 210x)" ::= { secCore 5 } --1.3.6.1.4.1.3052.17.2.11.1.5 scRTSLoginRequired OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF login required upon connecting to RTS (TCP ports 220x)" ::= { secCore 6 } --1.3.6.1.4.1.3052.17.2.11.1.6 scAuthMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Authentication mode (USERNAME/PW,PW/USERNAME,PASSWORD ONLY)" ::= { secCore 7 } --1.3.6.1.4.1.3052.17.2.11.1.7 scRightsGroup OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The set of aliases used for the 8 available rights levels" ::= { secCore 8 } --1.3.6.1.4.1.3052.17.2.11.1.8 scSecret OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Shared secret for challenges" ::= { secCore 9 } --1.3.6.1.4.1.3052.17.2.11.1.9 --*************************************************************************************** --User Security Section 2.11.2 --*************************************************************************************** secUserTable OBJECT-TYPE SYNTAX SEQUENCE OF SecUserConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of users" ::= { unitSecurity 2 } --1.3.6.1.4.1.3052.17.2.11.2 secUserEntry OBJECT-TYPE SYNTAX SecUserConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of users" INDEX { secUserIndex } ::= { secUserTable 1 } --1.3.6.1.4.1.3052.17.2.11.2.1 secUserIndex OBJECT-TYPE SYNTAX Integer32 (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of users" ::= { secUserEntry 1 } --1.3.6.1.4.1.3052.17.2.11.2.1.1 secUserEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF enable user" ::= { secUserEntry 2 } --1.3.6.1.4.1.3052.17.2.11.2.1.2 secUserConnectVia OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Methods by which user is allowed to connect: L=local (console) T=Telnet F=FTP R=RTS Ss=SSH W=Web " ::= { secUserEntry 5 } --1.3.6.1.4.1.3052.17.2.11.2.1.5 secUserLoginTo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The function presented to the user upon login (COMMAND, PASSTHROUGH,MENU)" ::= { secUserEntry 6 } --1.3.6.1.4.1.3052.17.2.11.2.1.6 secUserAccessFile OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The default access file associated with the user" ::= { secUserEntry 7 } --1.3.6.1.4.1.3052.17.2.11.2.1.7 secUserPTEscapeTo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The function presented to the user upon escaping pass- through: currently only MENU" ::= { secUserEntry 9 } --1.3.6.1.4.1.3052.17.2.11.2.1.9 secUserPPPType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The kind of PPP access allowed to this user cannot connect via PPP (NONE), can connect but only to the unit (LOCAL), or can connect and route to Ethernet (ROUTING)" ::= { secUserEntry 10 } --1.3.6.1.4.1.3052.17.2.11.2.1.10 secUserRights OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The rights level granted to this user" ::= { secUserEntry 11 } --1.3.6.1.4.1.3052.17.2.11.2.1.11 secUserEventsReadAccess OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "DENY/ALLOW user to read the events/alarms file" ::= { secUserEntry 13 } --1.3.6.1.4.1.3052.17.2.11.2.1.13 secUserAuditReadAccess OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "DENY/ALLOW user to read the audit log" ::= { secUserEntry 14 } --1.3.6.1.4.1.3052.17.2.11.2.1.14 secUserEventsWriteAccess OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "DENY/ALLOW user to delete the events file" ::= { secUserEntry 16 } --1.3.6.1.4.1.3052.17.2.11.2.1.16 secUserAuditWriteAccess OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "DENY/ALLOW user to write to the audit log" ::= { secUserEntry 17 } --1.3.6.1.4.1.3052.17.2.11.2.1.17 secUserExpiration OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Expiration date/time of this user" ::= { secUserEntry 18 } --1.3.6.1.4.1.3052.17.2.11.2.1.18 secUserCallbackNumber1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Number slot 1 the unit calls for dialback" ::= { secUserEntry 19 } --1.3.6.1.4.1.3052.17.2.11.2.1.19 secUserCallbackNumber2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Number slot 2 the unit calls for dialback" ::= { secUserEntry 20 } --1.3.6.1.4.1.3052.17.2.11.2.1.20 secUserCallbackNumber3 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Number slot 3 the unit calls for dialback" ::= { secUserEntry 21 } --1.3.6.1.4.1.3052.17.2.11.2.1.21 secUserChallengeTelnetMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Telnet challenge mode: when user logs in via telnet, unit allows access (OFF), presents a challenge (CHALLENGE), or unit sends a one-time-password (SEND PASSWORD) to a destination configured by secUserChallengeTelnetSendTo" ::= { secUserEntry 22 } --1.3.6.1.4.1.3052.17.2.11.2.1.22 secUserChallengeModemMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Modem challenge mode: when user logs in via modem, unit allows access (OFF), presents a challenge (CHALLENGE), sends a one-time-password (SEND PASSWORD) to a destination configured by secUserChallengeTelnetSendTo, or dials a number (CALLBACK) configured with secUserCallbackNumberx" ::= { secUserEntry 23 } --1.3.6.1.4.1.3052.17.2.11.2.1.23 secUserChallengeConsoleMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Console challenge mode: when user logs in via console, unit allows access (OFF), or presents a challenge (CHALLENGE)" ::= { secUserEntry 24 } --1.3.6.1.4.1.3052.17.2.11.2.1.24 secUserChallengeTelnetSendTo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Email action used as the destination address for one-time- password when a user logs in with a challenge mode of SEND PASSWORD" ::= { secUserEntry 25 } --1.3.6.1.4.1.3052.17.2.11.2.1.25 secUserChallengeModemSendTo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Modem action used as the destination phone number for one- time-password when a user logs in with a challenge mode of SEND PASSWORD" ::= { secUserEntry 26 } --1.3.6.1.4.1.3052.17.2.11.2.1.26 secUserChallengeExpiration OBJECT-TYPE SYNTAX Integer32 (0..180) MAX-ACCESS read-write STATUS current DESCRIPTION "Time (in minutes) after which a one-time-password is sent that it can be used to log in" ::= { secUserEntry 27 } --1.3.6.1.4.1.3052.17.2.11.2.1.27 --*************************************************************************************** --Factory Security Section 2.11.3 --*************************************************************************************** sfEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF enable factory access" ::= { secFactory 1 } --1.3.6.1.4.1.3052.17.2.11.3.1 sfSecret OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Secret used for factory access" ::= { secFactory 2 } --1.3.6.1.4.1.3052.17.2.11.3.2 --*************************************************************************************** --Event Section 2.12 --*************************************************************************************** --*************************************************************************************** --Event Core Section 2.12.1 --*************************************************************************************** evClassNameTable OBJECT-TYPE SYNTAX SEQUENCE OF EventClassConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of classes" ::= { evCore 1 } --1.3.6.1.4.1.3052.17.2.12.1.1 evClassNameEntry OBJECT-TYPE SYNTAX EventClassConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of classes" INDEX { evClassNameIndex } ::= { evClassNameTable 1 } --1.3.6.1.4.1.3052.17.2.12.1.1.1 evClassNameIndex OBJECT-TYPE SYNTAX Integer32 (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of classes" ::= { evClassNameEntry 1 } --1.3.6.1.4.1.3052.17.2.12.1.1.1.1 evClassName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class name for this slot" ::= { evClassNameEntry 2 } --1.3.6.1.4.1.3052.17.2.12.1.1.1.2 evReminderInterval OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Interval (minutes) between EventSensor reminder events" ::= { evCore 2 } --1.3.6.1.4.1.3052.17.2.12.1.2 evLogEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF enable event log" ::= { evLog 1 } --1.3.6.1.4.1.3052.17.2.12.1.3.1 evLogStoreAlarm OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF store data alarms in event log" ::= { evLog 2 } --1.3.6.1.4.1.3052.17.2.12.1.3.2 evLogMaxSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "max size (in KB) of event log" ::= { evLog 3 } --1.3.6.1.4.1.3052.17.2.12.1.3.3 evLogStoreSensor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF store EventSensor events in event log" ::= { evLog 4 } --1.3.6.1.4.1.3052.17.2.12.1.3.4 evLogTimeStampAlarms OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF put timestamps on event log entries" ::= { evLog 5 } --1.3.6.1.4.1.3052.17.2.12.1.3.5 evLogPrependName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF prepend data event name to data alarm records in event log" ::= { evLog 6 } --1.3.6.1.4.1.3052.17.2.12.1.3.6 evMgmtReprocess OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Number of sensors that have generated events since reset. Write this to reprocess each sensor's last generated event since reset. The value to write determines what kind of events should be reprocessed: 'all': all sensor events 'cc': cc events 'temperature': temperature events 'humidity': humidity events 'analog': analog input events 'fuel': fuel sensor events 'acpm': AC power monitor events 'battery': battery monitor events" ::= { evMgmt 3 } --1.3.6.1.4.1.3052.17.2.12.1.4.3 --*************************************************************************************** --Scheduled Event 1 Section 2.12.5 --*************************************************************************************** evSched1Enable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF enable this scheduled event" ::= { evSched1 1 } --1.3.6.1.4.1.3052.17.2.12.5.1 evSched1Actions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for this scheduled event" ::= { evSched1 2 } --1.3.6.1.4.1.3052.17.2.12.5.2 evSched1Message OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Message for this scheduled event" ::= { evSched1 3 } --1.3.6.1.4.1.3052.17.2.12.5.3 evSched1TrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for this scheduled event" ::= { evSched1 4 } --1.3.6.1.4.1.3052.17.2.12.5.4 evSched1Class OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for this scheduled event" ::= { evSched1 5 } --1.3.6.1.4.1.3052.17.2.12.5.5 evSched1Sunday OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time on Sunday (HH:MM) when this scheduled event triggers" ::= { evSched1 6 } --1.3.6.1.4.1.3052.17.2.12.5.6 evSched1Monday OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time on Monday (HH:MM) when this scheduled event triggers" ::= { evSched1 7 } --1.3.6.1.4.1.3052.17.2.12.5.7 evSched1Tuesday OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time on Tuesday (HH:MM) when this scheduled event triggers" ::= { evSched1 8 } --1.3.6.1.4.1.3052.17.2.12.5.8 evSched1Wednesday OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time on Wednesday (HH:MM) when this scheduled event triggers" ::= { evSched1 9 } --1.3.6.1.4.1.3052.17.2.12.5.9 evSched1Thursday OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time on Thursday (HH:MM) when this scheduled event triggers" ::= { evSched1 10 } --1.3.6.1.4.1.3052.17.2.12.5.10 evSched1Friday OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time on Friday (HH:MM) when this scheduled event triggers" ::= { evSched1 11 } --1.3.6.1.4.1.3052.17.2.12.5.11 evSched1Saturday OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time on Saturday (HH:MM) when this scheduled event triggers" ::= { evSched1 12 } --1.3.6.1.4.1.3052.17.2.12.5.12 evSched1Exclusions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Exclusions (space-separated MM/DD-formatted dates) for this scheduled event" ::= { evSched1 13 } --1.3.6.1.4.1.3052.17.2.12.5.13 --*************************************************************************************** --Scheduled Event 2 Section 2.12.6 --*************************************************************************************** evSched2Enable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF enable this scheduled event" ::= { evSched2 1 } --1.3.6.1.4.1.3052.17.2.12.6.1 evSched2Actions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for this scheduled event" ::= { evSched2 2 } --1.3.6.1.4.1.3052.17.2.12.6.2 evSched2Message OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Message for this scheduled event" ::= { evSched2 3 } --1.3.6.1.4.1.3052.17.2.12.6.3 evSched2TrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for this scheduled event" ::= { evSched2 4 } --1.3.6.1.4.1.3052.17.2.12.6.4 evSched2Class OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for this scheduled event" ::= { evSched2 5 } --1.3.6.1.4.1.3052.17.2.12.6.5 evSched2Sunday OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time on Sunday (HH:MM) when this scheduled event triggers" ::= { evSched2 6 } --1.3.6.1.4.1.3052.17.2.12.6.6 evSched2Monday OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time on Monday (HH:MM) when this scheduled event triggers" ::= { evSched2 7 } --1.3.6.1.4.1.3052.17.2.12.6.7 evSched2Tuesday OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time on Tuesday (HH:MM) when this scheduled event triggers" ::= { evSched2 8 } --1.3.6.1.4.1.3052.17.2.12.6.8 evSched2Wednesday OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time on Wednesday (HH:MM) when this scheduled event triggers" ::= { evSched2 9 } --1.3.6.1.4.1.3052.17.2.12.6.9 evSched2Thursday OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time on Thursday (HH:MM) when this scheduled event triggers" ::= { evSched2 10 } --1.3.6.1.4.1.3052.17.2.12.6.10 evSched2Friday OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time on Friday (HH:MM) when this scheduled event triggers" ::= { evSched2 11 } --1.3.6.1.4.1.3052.17.2.12.6.11 evSched2Saturday OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time on Saturday (HH:MM) when this scheduled event triggers" ::= { evSched2 12 } --1.3.6.1.4.1.3052.17.2.12.6.12 evSched2Exclusions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Exclusions (space-separated MM/DD-formatted dates) for this scheduled event" ::= { evSched2 13 } --1.3.6.1.4.1.3052.17.2.12.6.13 --*************************************************************************************** --Serial Handshaking Low Section 2.12.7 --*************************************************************************************** evShskLowTable OBJECT-TYPE SYNTAX SEQUENCE OF SerialHandshakingLowEventConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of serial handshaking low events" ::= { event 7 } --1.3.6.1.4.1.3052.17.2.12.7 evShskLowEntry OBJECT-TYPE SYNTAX SerialHandshakingLowEventConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of serial handshaking low events" INDEX { evShskLowIndex } ::= { evShskLowTable 1 } --1.3.6.1.4.1.3052.17.2.12.7.1 evShskLowIndex OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of serial handshaking low events" ::= { evShskLowEntry 1 } --1.3.6.1.4.1.3052.17.2.12.7.1.1 evShskLowEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF: enable the serial handshaking low event for this port" ::= { evShskLowEntry 2 } --1.3.6.1.4.1.3052.17.2.12.7.1.2 evShskLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for the serial handshaking low event for this port" ::= { evShskLowEntry 3 } --1.3.6.1.4.1.3052.17.2.12.7.1.3 evShskLowMessage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Message for the serial handshaking low event for this port" ::= { evShskLowEntry 4 } --1.3.6.1.4.1.3052.17.2.12.7.1.4 evShskLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for the serial handshaking low event for this port" ::= { evShskLowEntry 5 } --1.3.6.1.4.1.3052.17.2.12.7.1.5 evShskLowTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for the serial handshaking low event for this port" ::= { evShskLowEntry 6 } --1.3.6.1.4.1.3052.17.2.12.7.1.6 --*************************************************************************************** --Serial Handshaking High Section 2.12.8 --*************************************************************************************** evShskHighTable OBJECT-TYPE SYNTAX SEQUENCE OF SerialHandshakingHighEventConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of serial handshaking high events" ::= { event 8 } --1.3.6.1.4.1.3052.17.2.12.8 evShskHighEntry OBJECT-TYPE SYNTAX SerialHandshakingHighEventConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of serial handshaking high events" INDEX { evShskHighIndex } ::= { evShskHighTable 1 } --1.3.6.1.4.1.3052.17.2.12.8.1 evShskHighIndex OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of serial handshaking high events" ::= { evShskHighEntry 1 } --1.3.6.1.4.1.3052.17.2.12.8.1.1 evShskHighEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF: enable the serial handshaking high event for this port" ::= { evShskHighEntry 2 } --1.3.6.1.4.1.3052.17.2.12.8.1.2 evShskHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for the serial handshaking high event for this port" ::= { evShskHighEntry 3 } --1.3.6.1.4.1.3052.17.2.12.8.1.3 evShskHighMessage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Message for the serial handshaking high event for this port" ::= { evShskHighEntry 4 } --1.3.6.1.4.1.3052.17.2.12.8.1.4 evShskHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for the serial handshaking high event for this port" ::= { evShskHighEntry 5 } --1.3.6.1.4.1.3052.17.2.12.8.1.5 evShskHighTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for the serial handshaking high event for this port" ::= { evShskHighEntry 6 } --1.3.6.1.4.1.3052.17.2.12.8.1.6 --*************************************************************************************** --No Sensor Event Section 2.12.9 --*************************************************************************************** evNoSensorTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Timeout (seconds) after which an EventSensor becomes unresponsive that this event is triggered" ::= { evNoSensor 1 } --1.3.6.1.4.1.3052.17.2.12.9.1 evNoSensorActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for no sensor event" ::= { evNoSensor 2 } --1.3.6.1.4.1.3052.17.2.12.9.2 evNoSensorTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for no sensor event" ::= { evNoSensor 3 } --1.3.6.1.4.1.3052.17.2.12.9.3 evNoSensorClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for no sensor event" ::= { evNoSensor 4 } --1.3.6.1.4.1.3052.17.2.12.9.4 --*************************************************************************************** --Fuel Sensor Config Section 2.12.11 --*************************************************************************************** fuelSensorGeneralTable OBJECT-TYPE SYNTAX SEQUENCE OF FuelSensorConfigGeneral MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes general fuel sensor attributes." ::= { fuelSensor 1 } --1.3.6.1.4.1.3052.17.2.12.11.1 fsGenEntry OBJECT-TYPE SYNTAX FuelSensorConfigGeneral MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for fuel sensor general config table." INDEX { fsGenIndex } ::= { fuelSensorGeneralTable 1 } --1.3.6.1.4.1.3052.17.2.12.11.1.1 fsGenIndex OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-only STATUS current DESCRIPTION "Which fuel sensor in the fuel sensor general config table." ::= { fsGenEntry 1 } --1.3.6.1.4.1.3052.17.2.12.11.1.1.1 fsGenName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor name." ::= { fsGenEntry 2 } --1.3.6.1.4.1.3052.17.2.12.11.1.1.2 fsGenSensorType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Type of fuel sensor in use; NONE disables the fuel sensor." ::= { fsGenEntry 3 } --1.3.6.1.4.1.3052.17.2.12.11.1.1.3 fsGenDistanceUnit OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Distance units in use when setting and indicating tank dimensions." ::= { fsGenEntry 4 } --1.3.6.1.4.1.3052.17.2.12.11.1.1.4 fsGenRawValueTop OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Analog input reading corresponding to the SENSOR FULL point." ::= { fsGenEntry 5 } --1.3.6.1.4.1.3052.17.2.12.11.1.1.5 fsGenTopOffset OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Distance, in the specified distance unit, between the SENSOR FULL point and the TANK FULL point. The value is positive if the SENSOR FULL point is above the TANK FULL point, and negative if it is below." ::= { fsGenEntry 6 } --1.3.6.1.4.1.3052.17.2.12.11.1.1.6 fsGenRawValueBottom OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Analog input reading corresponding to the minimum fluid height measurable by the fuel sensor." ::= { fsGenEntry 7 } --1.3.6.1.4.1.3052.17.2.12.11.1.1.7 fsGenBottomOffset OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Distance, in the specified distance unit, between the SENSOR EMPTY point and the TANK EMPTY point. The value is positive if the SENSOR EMPTY point is above the TANK EMPTY point, and negative if it is below." ::= { fsGenEntry 8 } --1.3.6.1.4.1.3052.17.2.12.11.1.1.8 fsGenInputES OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-write STATUS current DESCRIPTION "Which eventsensor contains the analog input associated with this fuel sensor. Allowed values are 200 (for internal ES), or 1-16." ::= { fsGenEntry 9 } --1.3.6.1.4.1.3052.17.2.12.11.1.1.9 fsGenInputPoint OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-write STATUS current DESCRIPTION "Which analog input point, on the specified eventsensor, that is associated with the fuel sensor." ::= { fsGenEntry 10 } --1.3.6.1.4.1.3052.17.2.12.11.1.1.10 fsGenFilterAveraging OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor filter averaging factor." ::= { fsGenEntry 11 } --1.3.6.1.4.1.3052.17.2.12.11.1.1.11 fsGenSysrepEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor System Reporting enable." ::= { fsGenEntry 12 } --1.3.6.1.4.1.3052.17.2.12.11.1.1.12 fsGenSysrepThreshold OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor System Reporting threshold (floating point value)." ::= { fsGenEntry 13 } --1.3.6.1.4.1.3052.17.2.12.11.1.1.13 fsGenSysrepLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor System Reporting limit." ::= { fsGenEntry 14 } --1.3.6.1.4.1.3052.17.2.12.11.1.1.14 fsGenSysrepPackage OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor System Reporting package number." ::= { fsGenEntry 15 } --1.3.6.1.4.1.3052.17.2.12.11.1.1.15 fsGenSysrepType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor ASM profile type." ::= { fsGenEntry 16 } --1.3.6.1.4.1.3052.17.2.12.11.1.1.16 fuelSensorTankTable OBJECT-TYPE SYNTAX SEQUENCE OF FuelSensorConfigTank MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes tank-specific fuel sensor attributes." ::= { fuelSensor 2 } --1.3.6.1.4.1.3052.17.2.12.11.2 fsTankEntry OBJECT-TYPE SYNTAX FuelSensorConfigTank MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for fuel sensor tank config table." INDEX { fsTankIndex } ::= { fuelSensorTankTable 1 } --1.3.6.1.4.1.3052.17.2.12.11.2.1 fsTankIndex OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-only STATUS current DESCRIPTION "Which fuel sensor in the fuel sensor tank config table." ::= { fsTankEntry 1 } --1.3.6.1.4.1.3052.17.2.12.11.2.1.1 fsTankHeight OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Height of the tank, from the TANK EMPTY point to the TANK FULL point, in the specified distance unit (i.e. TANK HEIGHT). This is a floating point value." ::= { fsTankEntry 2 } --1.3.6.1.4.1.3052.17.2.12.11.2.1.2 fsTankDimA OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Tank dimension measurement A for certain tank profiles. For HORIZ OVAL, this is the length of the straight section. This is a floating point value." ::= { fsTankEntry 3 } --1.3.6.1.4.1.3052.17.2.12.11.2.1.3 fsTankDimB OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Tank dimension measurement B for certain tank profiles. For HORIZ OVAL, this is the radius of the curved section. This is a floating point value." ::= { fsTankEntry 4 } --1.3.6.1.4.1.3052.17.2.12.11.2.1.4 fsTankVolume OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "How many volume units the tank contains, when full. This is a floating point value." ::= { fsTankEntry 5 } --1.3.6.1.4.1.3052.17.2.12.11.2.1.5 fsTankVolumeUnit OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Name of the unit representing fluid volume in the tank. This is only used for display purposes; it does not affect the volume calculation." ::= { fsTankEntry 6 } --1.3.6.1.4.1.3052.17.2.12.11.2.1.6 fsTankShape OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The shape of the fuel tank. A value of LINEAR produces a fluid volume reading that is directly proportional to fluid height. The HORIZ CYL and HORIZ OVAL settings use a hard-coded formula to calculate the volume. The CUSTOM setting uses a strapping table that must be configured as well (see fuelSensorCustomTankTable)." ::= { fsTankEntry 7 } --1.3.6.1.4.1.3052.17.2.12.11.2.1.7 fuelSensorCustomTankTable OBJECT-TYPE SYNTAX SEQUENCE OF FuelSensorConfigCustomTankStrapping MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes the custom tank strapping table. Each fuel sensor has a table of height/volume pairs in service only when the tank shape (fsTankShape) in CUSTOM. This allows the unit to calculate volumes for nonstandard tank shapes, to the degree that accurate height/volume measurements can be configured. This SNMP table has two indexes: the first for which fuel sensor and the second for which height/volume pair." ::= { fuelSensor 3 } --1.3.6.1.4.1.3052.17.2.12.11.3 fsCustomTankEntry OBJECT-TYPE SYNTAX FuelSensorConfigCustomTankStrapping MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for fuel sensor custom tank config table." INDEX { fsCustomTankIndexFS, fsCustomTankIndexDatum } ::= { fuelSensorCustomTankTable 1 } --1.3.6.1.4.1.3052.17.2.12.11.3.1 fsCustomTankIndexFS OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-only STATUS current DESCRIPTION "Which fuel sensor in the fuel sensor tank config table. This is the first of two indexes for this SNMP table." ::= { fsCustomTankEntry 1 } --1.3.6.1.4.1.3052.17.2.12.11.3.1.1 fsCustomTankIndexDatum OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Which hight/volume pair: there are 32 pairs per fuel sensor. This is the second of two indexes for this SNMP table." ::= { fsCustomTankEntry 2 } --1.3.6.1.4.1.3052.17.2.12.11.3.1.2 fsCustomTankHeight OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Height of custom tank height/volume pair. This is a floating point value." ::= { fsCustomTankEntry 3 } --1.3.6.1.4.1.3052.17.2.12.11.3.1.3 fsCustomTankVolume OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Volume of custom tank height/volume pair. This is a floating point value." ::= { fsCustomTankEntry 4 } --1.3.6.1.4.1.3052.17.2.12.11.3.1.4 fuelSensorVolumeTable OBJECT-TYPE SYNTAX SEQUENCE OF FuelSensorConfigVolume MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes volume-event-specific fuel sensor attributes." ::= { fuelSensor 4 } --1.3.6.1.4.1.3052.17.2.12.11.4 fsVolumeEntry OBJECT-TYPE SYNTAX FuelSensorConfigVolume MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for fuel sensor volume event config table." INDEX { fsVolumeIndex } ::= { fuelSensorVolumeTable 1 } --1.3.6.1.4.1.3052.17.2.12.11.4.1 fsVolumeIndex OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-only STATUS current DESCRIPTION "Which fuel sensor in the fuel sensor volume event config table." ::= { fsVolumeEntry 1 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.1 fsVolumeEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable fuel sensor volume events." ::= { fsVolumeEntry 2 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.2 fsVolumeDeadband OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor deadband (hysteresis). This is a floating point value." ::= { fsVolumeEntry 3 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.3 fsVolumeVHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume very high event threshold value. This is a floating point value." ::= { fsVolumeEntry 4 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.4 fsVolumeVHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume very high event threshold actions." ::= { fsVolumeEntry 5 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.5 fsVolumeVHighTrapNum OBJECT-TYPE SYNTAX Integer32 (519..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume very high event threshold trap number." ::= { fsVolumeEntry 6 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.6 fsVolumeVHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume very high event threshold class (severity)." ::= { fsVolumeEntry 7 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.7 fsVolumeHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume high event threshold value. This is a floating point value." ::= { fsVolumeEntry 8 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.8 fsVolumeHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume high event threshold actions." ::= { fsVolumeEntry 9 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.9 fsVolumeHighTrapNum OBJECT-TYPE SYNTAX Integer32 (519..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume high event threshold trap number." ::= { fsVolumeEntry 10 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.10 fsVolumeHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume high event threshold class (severity)." ::= { fsVolumeEntry 11 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.11 fsVolumeNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume return to normal actions." ::= { fsVolumeEntry 12 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.12 fsVolumeNormalTrapNum OBJECT-TYPE SYNTAX Integer32 (519..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume return to normal trap number." ::= { fsVolumeEntry 13 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.13 fsVolumeNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume return to normal class (severity)." ::= { fsVolumeEntry 14 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.14 fsVolumeLowValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume low event threshold value. This is a floating point value." ::= { fsVolumeEntry 15 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.15 fsVolumeLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume low event threshold actions." ::= { fsVolumeEntry 16 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.16 fsVolumeLowTrapNum OBJECT-TYPE SYNTAX Integer32 (519..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume low event threshold trap number." ::= { fsVolumeEntry 17 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.17 fsVolumeLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume low event threshold class (severity)." ::= { fsVolumeEntry 18 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.18 fsVolumeVLowValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume very low event threshold value. This is a floating point value." ::= { fsVolumeEntry 19 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.19 fsVolumeVLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume very low event threshold actions." ::= { fsVolumeEntry 20 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.20 fsVolumeVLowTrapNum OBJECT-TYPE SYNTAX Integer32 (519..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume very low event threshold trap number." ::= { fsVolumeEntry 21 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.21 fsVolumeVLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor volume very low event threshold class (severity)." ::= { fsVolumeEntry 22 } --1.3.6.1.4.1.3052.17.2.12.11.4.1.22 fuelSensorDisconnectTable OBJECT-TYPE SYNTAX SEQUENCE OF FuelSensorConfigDisconnect MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes disconnect-event-specific fuel sensor attributes." ::= { fuelSensor 5 } --1.3.6.1.4.1.3052.17.2.12.11.5 fsDiscEntry OBJECT-TYPE SYNTAX FuelSensorConfigDisconnect MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for fuel sensor disconnect event config table." INDEX { fsDiscIndex } ::= { fuelSensorDisconnectTable 1 } --1.3.6.1.4.1.3052.17.2.12.11.5.1 fsDiscIndex OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-only STATUS current DESCRIPTION "Which fuel sensor in the fuel sensor disconnect event config table." ::= { fsDiscEntry 1 } --1.3.6.1.4.1.3052.17.2.12.11.5.1.1 fsDiscEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor disconnect event enable." ::= { fsDiscEntry 2 } --1.3.6.1.4.1.3052.17.2.12.11.5.1.2 fsDiscHighValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "High end of input value range when fuel sensor is disconnected. This is in the units of the analog input value." ::= { fsDiscEntry 3 } --1.3.6.1.4.1.3052.17.2.12.11.5.1.3 fsDiscLowValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Low end of input value range when fuel sensor is disconnected. This is in the units of the analog input value." ::= { fsDiscEntry 4 } --1.3.6.1.4.1.3052.17.2.12.11.5.1.4 fsDiscActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor disconnect event actions." ::= { fsDiscEntry 5 } --1.3.6.1.4.1.3052.17.2.12.11.5.1.5 fsDiscTrapNum OBJECT-TYPE SYNTAX Integer32 (515..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor disconnect event trap number." ::= { fsDiscEntry 6 } --1.3.6.1.4.1.3052.17.2.12.11.5.1.6 fsDiscClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor disconnect event class (severity)." ::= { fsDiscEntry 7 } --1.3.6.1.4.1.3052.17.2.12.11.5.1.7 fsDiscNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor disconnect return to normal actions." ::= { fsDiscEntry 8 } --1.3.6.1.4.1.3052.17.2.12.11.5.1.8 fsDiscNormalTrapNum OBJECT-TYPE SYNTAX Integer32 (515..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor disconnect return to normal trap number." ::= { fsDiscEntry 9 } --1.3.6.1.4.1.3052.17.2.12.11.5.1.9 fsDiscNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel sensor disconnect return to normal class (severity)." ::= { fsDiscEntry 10 } --1.3.6.1.4.1.3052.17.2.12.11.5.1.10 fuelSensorSuddenChangeTable OBJECT-TYPE SYNTAX SEQUENCE OF FuelSensorConfigSuddenChange MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes sudden-change-event-specific fuel sensor attributes." ::= { fuelSensor 6 } --1.3.6.1.4.1.3052.17.2.12.11.6 fsSuddenChangeEntry OBJECT-TYPE SYNTAX FuelSensorConfigSuddenChange MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for fuel sensor sudden change event config table." INDEX { fsSuddenChangeIndex } ::= { fuelSensorSuddenChangeTable 1 } --1.3.6.1.4.1.3052.17.2.12.11.6.1 fsSuddenChangeIndex OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-only STATUS current DESCRIPTION "Which fuel sensor in the fuel sensor disconnect event config table." ::= { fsSuddenChangeEntry 1 } --1.3.6.1.4.1.3052.17.2.12.11.6.1.1 fsSuddenChangeEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel volume sudden change event enable." ::= { fsSuddenChangeEntry 2 } --1.3.6.1.4.1.3052.17.2.12.11.6.1.2 fsSuddenChangeTime OBJECT-TYPE SYNTAX Integer32 (5..360) MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel volume sudden change event time (minutes): what duration defines 'sudden'." ::= { fsSuddenChangeEntry 3 } --1.3.6.1.4.1.3052.17.2.12.11.6.1.3 fsSuddenChangeAmplitude OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel volume sudden change event amplitude: what amount (in fuel volume units) over the duration (fsSuddenChangeTime) defines enough change." ::= { fsSuddenChangeEntry 4 } --1.3.6.1.4.1.3052.17.2.12.11.6.1.4 fsSuddenChangeActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel volume sudden change event actions." ::= { fsSuddenChangeEntry 5 } --1.3.6.1.4.1.3052.17.2.12.11.6.1.5 fsSuddenChangeTrapNum OBJECT-TYPE SYNTAX Integer32 (527..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel volume sudden change event trap number." ::= { fsSuddenChangeEntry 6 } --1.3.6.1.4.1.3052.17.2.12.11.6.1.6 fsSuddenChangeClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel volume sudden change event class (severity)." ::= { fsSuddenChangeEntry 7 } --1.3.6.1.4.1.3052.17.2.12.11.6.1.7 fuelSensorSlowChangeTable OBJECT-TYPE SYNTAX SEQUENCE OF FuelSensorConfigSlowChange MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes slow-change-event-specific fuel sensor attributes." ::= { fuelSensor 7 } --1.3.6.1.4.1.3052.17.2.12.11.7 fsSlowChangeEntry OBJECT-TYPE SYNTAX FuelSensorConfigSlowChange MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for fuel sensor slow change event config table." INDEX { fsSlowChangeIndex } ::= { fuelSensorSlowChangeTable 1 } --1.3.6.1.4.1.3052.17.2.12.11.7.1 fsSlowChangeIndex OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-only STATUS current DESCRIPTION "Which fuel sensor in the fuel sensor disconnect event config table." ::= { fsSlowChangeEntry 1 } --1.3.6.1.4.1.3052.17.2.12.11.7.1.1 fsSlowChangeEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel volume slow change event enable." ::= { fsSlowChangeEntry 2 } --1.3.6.1.4.1.3052.17.2.12.11.7.1.2 fsSlowChangeTime OBJECT-TYPE SYNTAX Integer32 (1..168) MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel volume slow change event time (minutes): what duration defines 'slow'." ::= { fsSlowChangeEntry 3 } --1.3.6.1.4.1.3052.17.2.12.11.7.1.3 fsSlowChangeAmplitude OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel volume slow change event amplitude: what amount (in fuel volume units) over the duration (fsSlowChangeTime) defines enough change." ::= { fsSlowChangeEntry 4 } --1.3.6.1.4.1.3052.17.2.12.11.7.1.4 fsSlowChangeActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel volume slow change event actions." ::= { fsSlowChangeEntry 5 } --1.3.6.1.4.1.3052.17.2.12.11.7.1.5 fsSlowChangeTrapNum OBJECT-TYPE SYNTAX Integer32 (528..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel volume slow change event trap number." ::= { fsSlowChangeEntry 6 } --1.3.6.1.4.1.3052.17.2.12.11.7.1.6 fsSlowChangeClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Fuel volume slow change event class (severity)." ::= { fsSlowChangeEntry 7 } --1.3.6.1.4.1.3052.17.2.12.11.7.1.7 --*************************************************************************************** --AC Power Monitor Config Section 2.12.12 --*************************************************************************************** acpmGeneralTable OBJECT-TYPE SYNTAX SEQUENCE OF ACPMConfigGeneral MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes general AC power monitor attributes." ::= { acPowerMonitor 1 } --1.3.6.1.4.1.3052.17.2.12.12.1 acpmGenEntry OBJECT-TYPE SYNTAX ACPMConfigGeneral MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for AC power monitor general config table." INDEX { acpmGenIndex } ::= { acpmGeneralTable 1 } --1.3.6.1.4.1.3052.17.2.12.12.1.1 acpmGenIndex OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Which AC power monitor in the AC power monitor general config table." ::= { acpmGenEntry 1 } --1.3.6.1.4.1.3052.17.2.12.12.1.1.1 acpmGenDevice OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Model of the AC power monitor device. The unit needs this setting to know which registers to poll for the various data items, among other things." ::= { acpmGenEntry 2 } --1.3.6.1.4.1.3052.17.2.12.12.1.1.2 acpmGenName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Name for the AC power monitor device." ::= { acpmGenEntry 3 } --1.3.6.1.4.1.3052.17.2.12.12.1.1.3 acpmGenAddress OBJECT-TYPE SYNTAX Integer32 (1..247) MAX-ACCESS read-write STATUS current DESCRIPTION "Modbus address of the AC power monitor device." ::= { acpmGenEntry 4 } --1.3.6.1.4.1.3052.17.2.12.12.1.1.4 acpmGenPtRatio OBJECT-TYPE SYNTAX Integer32 (1..10000) MAX-ACCESS read-write STATUS current DESCRIPTION "Ratio of secondary turns to primary turns on potential transformers (PT)." ::= { acpmGenEntry 5 } --1.3.6.1.4.1.3052.17.2.12.12.1.1.5 acpmGenCtRatio OBJECT-TYPE SYNTAX Integer32 (1..10000) MAX-ACCESS read-write STATUS current DESCRIPTION "Ratio of secondary turns to primary turns on current transformers (CT)." ::= { acpmGenEntry 6 } --1.3.6.1.4.1.3052.17.2.12.12.1.1.6 acpmGenPowerType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Type of power being monitored." ::= { acpmGenEntry 7 } --1.3.6.1.4.1.3052.17.2.12.12.1.1.7 acpmGenSysrepPackage OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting package number." ::= { acpmGenEntry 8 } --1.3.6.1.4.1.3052.17.2.12.12.1.1.8 acpmGenSysrepType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ASM profile type." ::= { acpmGenEntry 9 } --1.3.6.1.4.1.3052.17.2.12.12.1.1.9 acpmAvgVoltageTable OBJECT-TYPE SYNTAX SEQUENCE OF ACPMConfigAvgVoltage MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes AC power monitor average voltage attributes." ::= { acPowerMonitor 2 } --1.3.6.1.4.1.3052.17.2.12.12.2 acpmAvgVoltageEntry OBJECT-TYPE SYNTAX ACPMConfigAvgVoltage MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for AC power monitor average voltage config table." INDEX { acpmAvgVoltageIndex } ::= { acpmAvgVoltageTable 1 } --1.3.6.1.4.1.3052.17.2.12.12.2.1 acpmAvgVoltageIndex OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Which AC power monitor in the AC power monitor average voltage config table." ::= { acpmAvgVoltageEntry 1 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.1 acpmAvgVoltageEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable AC power monitor average voltage events." ::= { acpmAvgVoltageEntry 2 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.2 acpmAvgVoltageDeadband OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Deadband (hysteresis) for average voltage event. This is a floating point value." ::= { acpmAvgVoltageEntry 3 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.3 acpmAvgVoltageVHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event threshold. This is a floating point value." ::= { acpmAvgVoltageEntry 4 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.4 acpmAvgVoltageVHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event actions." ::= { acpmAvgVoltageEntry 5 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.5 acpmAvgVoltageVHighTrapNum OBJECT-TYPE SYNTAX Integer32 (520..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event trap number." ::= { acpmAvgVoltageEntry 6 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.6 acpmAvgVoltageVHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event class." ::= { acpmAvgVoltageEntry 7 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.7 acpmAvgVoltageHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event threshold. This is a floating point value." ::= { acpmAvgVoltageEntry 8 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.8 acpmAvgVoltageHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event actions." ::= { acpmAvgVoltageEntry 9 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.9 acpmAvgVoltageHighTrapNum OBJECT-TYPE SYNTAX Integer32 (520..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "High event trap number." ::= { acpmAvgVoltageEntry 10 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.10 acpmAvgVoltageHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event class." ::= { acpmAvgVoltageEntry 11 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.11 acpmAvgVoltageNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return to normal actions." ::= { acpmAvgVoltageEntry 12 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.12 acpmAvgVoltageNormalTrapNum OBJECT-TYPE SYNTAX Integer32 (520..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Return to normal trap number." ::= { acpmAvgVoltageEntry 13 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.13 acpmAvgVoltageNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return to normal class." ::= { acpmAvgVoltageEntry 14 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.14 acpmAvgVoltageLowValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event threshold. This is a floating point value." ::= { acpmAvgVoltageEntry 15 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.15 acpmAvgVoltageLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event actions." ::= { acpmAvgVoltageEntry 16 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.16 acpmAvgVoltageLowTrapNum OBJECT-TYPE SYNTAX Integer32 (520..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Low event trap number." ::= { acpmAvgVoltageEntry 17 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.17 acpmAvgVoltageLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event class." ::= { acpmAvgVoltageEntry 18 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.18 acpmAvgVoltageVLowValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event threshold. This is a floating point value." ::= { acpmAvgVoltageEntry 19 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.19 acpmAvgVoltageVLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event actions." ::= { acpmAvgVoltageEntry 20 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.20 acpmAvgVoltageVLowTrapNum OBJECT-TYPE SYNTAX Integer32 (520..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event trap number." ::= { acpmAvgVoltageEntry 21 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.21 acpmAvgVoltageVLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event class." ::= { acpmAvgVoltageEntry 22 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.22 acpmAvgVoltageSysrepEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting enable for average voltage telemetry." ::= { acpmAvgVoltageEntry 23 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.23 acpmAvgVoltageSysrepThreshold OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting threshold for average voltage telemetry. This is a floating point value." ::= { acpmAvgVoltageEntry 24 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.24 acpmAvgVoltageSysrepLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting limit for average voltage telemetry." ::= { acpmAvgVoltageEntry 25 } --1.3.6.1.4.1.3052.17.2.12.12.2.1.25 acpmAvgCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF ACPMConfigAvgCurrent MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes AC power monitor average current attributes." ::= { acPowerMonitor 3 } --1.3.6.1.4.1.3052.17.2.12.12.3 acpmAvgCurrentEntry OBJECT-TYPE SYNTAX ACPMConfigAvgCurrent MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for AC power monitor average current config table." INDEX { acpmAvgCurrentIndex } ::= { acpmAvgCurrentTable 1 } --1.3.6.1.4.1.3052.17.2.12.12.3.1 acpmAvgCurrentIndex OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Which AC power monitor in the AC power monitor average current config table." ::= { acpmAvgCurrentEntry 1 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.1 acpmAvgCurrentEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable AC power monitor average current events." ::= { acpmAvgCurrentEntry 2 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.2 acpmAvgCurrentDeadband OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Deadband (hysteresis) for average current event. This is a floating point value." ::= { acpmAvgCurrentEntry 3 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.3 acpmAvgCurrentVHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event threshold. This is a floating point value." ::= { acpmAvgCurrentEntry 4 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.4 acpmAvgCurrentVHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event actions." ::= { acpmAvgCurrentEntry 5 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.5 acpmAvgCurrentVHighTrapNum OBJECT-TYPE SYNTAX Integer32 (521..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event trap number." ::= { acpmAvgCurrentEntry 6 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.6 acpmAvgCurrentVHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event class." ::= { acpmAvgCurrentEntry 7 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.7 acpmAvgCurrentHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event threshold. This is a floating point value." ::= { acpmAvgCurrentEntry 8 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.8 acpmAvgCurrentHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event actions." ::= { acpmAvgCurrentEntry 9 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.9 acpmAvgCurrentHighTrapNum OBJECT-TYPE SYNTAX Integer32 (521..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "High event trap number." ::= { acpmAvgCurrentEntry 10 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.10 acpmAvgCurrentHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event class." ::= { acpmAvgCurrentEntry 11 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.11 acpmAvgCurrentNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return to normal actions." ::= { acpmAvgCurrentEntry 12 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.12 acpmAvgCurrentNormalTrapNum OBJECT-TYPE SYNTAX Integer32 (521..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Return to normal trap number." ::= { acpmAvgCurrentEntry 13 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.13 acpmAvgCurrentNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return to normal class." ::= { acpmAvgCurrentEntry 14 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.14 acpmAvgCurrentLowValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event threshold. This is a floating point value." ::= { acpmAvgCurrentEntry 15 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.15 acpmAvgCurrentLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event actions." ::= { acpmAvgCurrentEntry 16 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.16 acpmAvgCurrentLowTrapNum OBJECT-TYPE SYNTAX Integer32 (521..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Low event trap number." ::= { acpmAvgCurrentEntry 17 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.17 acpmAvgCurrentLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event class." ::= { acpmAvgCurrentEntry 18 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.18 acpmAvgCurrentVLowValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event threshold. This is a floating point value." ::= { acpmAvgCurrentEntry 19 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.19 acpmAvgCurrentVLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event actions." ::= { acpmAvgCurrentEntry 20 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.20 acpmAvgCurrentVLowTrapNum OBJECT-TYPE SYNTAX Integer32 (521..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event trap number." ::= { acpmAvgCurrentEntry 21 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.21 acpmAvgCurrentVLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event class." ::= { acpmAvgCurrentEntry 22 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.22 acpmAvgCurrentSysrepEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting enable for average current telemetry." ::= { acpmAvgCurrentEntry 23 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.23 acpmAvgCurrentSysrepThreshold OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting threshold for average current telemetry. This is a floating point value." ::= { acpmAvgCurrentEntry 24 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.24 acpmAvgCurrentSysrepLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting limit for average current telemetry." ::= { acpmAvgCurrentEntry 25 } --1.3.6.1.4.1.3052.17.2.12.12.3.1.25 acpmFreqTable OBJECT-TYPE SYNTAX SEQUENCE OF ACPMConfigFreq MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes AC power monitor frequency attributes." ::= { acPowerMonitor 4 } --1.3.6.1.4.1.3052.17.2.12.12.4 acpmFreqEntry OBJECT-TYPE SYNTAX ACPMConfigFreq MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for AC power monitor frequency config table." INDEX { acpmFreqIndex } ::= { acpmFreqTable 1 } --1.3.6.1.4.1.3052.17.2.12.12.4.1 acpmFreqIndex OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Which AC power monitor in the AC power monitor frequency config table." ::= { acpmFreqEntry 1 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.1 acpmFreqEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable AC power monitor frequency events." ::= { acpmFreqEntry 2 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.2 acpmFreqDeadband OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Deadband (hysteresis) for frequency event. This is a floating point value." ::= { acpmFreqEntry 3 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.3 acpmFreqVHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event threshold. This is a floating point value." ::= { acpmFreqEntry 4 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.4 acpmFreqVHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event actions." ::= { acpmFreqEntry 5 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.5 acpmFreqVHighTrapNum OBJECT-TYPE SYNTAX Integer32 (522..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event trap number." ::= { acpmFreqEntry 6 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.6 acpmFreqVHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event class." ::= { acpmFreqEntry 7 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.7 acpmFreqHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event threshold. This is a floating point value." ::= { acpmFreqEntry 8 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.8 acpmFreqHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event actions." ::= { acpmFreqEntry 9 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.9 acpmFreqHighTrapNum OBJECT-TYPE SYNTAX Integer32 (522..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "High event trap number." ::= { acpmFreqEntry 10 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.10 acpmFreqHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event class." ::= { acpmFreqEntry 11 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.11 acpmFreqNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return to normal actions." ::= { acpmFreqEntry 12 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.12 acpmFreqNormalTrapNum OBJECT-TYPE SYNTAX Integer32 (522..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Return to normal trap number." ::= { acpmFreqEntry 13 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.13 acpmFreqNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return to normal class." ::= { acpmFreqEntry 14 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.14 acpmFreqLowValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event threshold. This is a floating point value." ::= { acpmFreqEntry 15 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.15 acpmFreqLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event actions." ::= { acpmFreqEntry 16 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.16 acpmFreqLowTrapNum OBJECT-TYPE SYNTAX Integer32 (522..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Low event trap number." ::= { acpmFreqEntry 17 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.17 acpmFreqLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event class." ::= { acpmFreqEntry 18 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.18 acpmFreqVLowValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event threshold. This is a floating point value." ::= { acpmFreqEntry 19 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.19 acpmFreqVLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event actions." ::= { acpmFreqEntry 20 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.20 acpmFreqVLowTrapNum OBJECT-TYPE SYNTAX Integer32 (522..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event trap number." ::= { acpmFreqEntry 21 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.21 acpmFreqVLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event class." ::= { acpmFreqEntry 22 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.22 acpmFreqSysrepEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting enable for frequency telemetry." ::= { acpmFreqEntry 23 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.23 acpmFreqSysrepThreshold OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting threshold for frequency telemetry. This is a floating point value." ::= { acpmFreqEntry 24 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.24 acpmFreqSysrepLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting limit for frequency telemetry." ::= { acpmFreqEntry 25 } --1.3.6.1.4.1.3052.17.2.12.12.4.1.25 acpmTotalRealPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF ACPMConfigTRP MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes AC power monitor total real power attributes." ::= { acPowerMonitor 5 } --1.3.6.1.4.1.3052.17.2.12.12.5 acpmTRPEntry OBJECT-TYPE SYNTAX ACPMConfigTRP MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for AC power monitor total real power config table." INDEX { acpmTRPIndex } ::= { acpmTotalRealPowerTable 1 } --1.3.6.1.4.1.3052.17.2.12.12.5.1 acpmTRPIndex OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Which AC power monitor in the AC power monitor total real power config table." ::= { acpmTRPEntry 1 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.1 acpmTRPEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable AC power monitor total real power events." ::= { acpmTRPEntry 2 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.2 acpmTRPDeadband OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Deadband (hysteresis) for total real power event. This is a floating point value." ::= { acpmTRPEntry 3 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.3 acpmTRPVHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event threshold. This is a floating point value." ::= { acpmTRPEntry 4 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.4 acpmTRPVHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event actions." ::= { acpmTRPEntry 5 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.5 acpmTRPVHighTrapNum OBJECT-TYPE SYNTAX Integer32 (523..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event trap number." ::= { acpmTRPEntry 6 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.6 acpmTRPVHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event class." ::= { acpmTRPEntry 7 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.7 acpmTRPHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event threshold. This is a floating point value." ::= { acpmTRPEntry 8 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.8 acpmTRPHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event actions." ::= { acpmTRPEntry 9 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.9 acpmTRPHighTrapNum OBJECT-TYPE SYNTAX Integer32 (523..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "High event trap number." ::= { acpmTRPEntry 10 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.10 acpmTRPHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event class." ::= { acpmTRPEntry 11 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.11 acpmTRPNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return to normal actions." ::= { acpmTRPEntry 12 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.12 acpmTRPNormalTrapNum OBJECT-TYPE SYNTAX Integer32 (523..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Return to normal trap number." ::= { acpmTRPEntry 13 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.13 acpmTRPNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return to normal class." ::= { acpmTRPEntry 14 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.14 acpmTRPLowValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event threshold. This is a floating point value." ::= { acpmTRPEntry 15 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.15 acpmTRPLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event actions." ::= { acpmTRPEntry 16 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.16 acpmTRPLowTrapNum OBJECT-TYPE SYNTAX Integer32 (523..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Low event trap number." ::= { acpmTRPEntry 17 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.17 acpmTRPLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event class." ::= { acpmTRPEntry 18 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.18 acpmTRPVLowValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event threshold. This is a floating point value." ::= { acpmTRPEntry 19 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.19 acpmTRPVLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event actions." ::= { acpmTRPEntry 20 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.20 acpmTRPVLowTrapNum OBJECT-TYPE SYNTAX Integer32 (523..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event trap number." ::= { acpmTRPEntry 21 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.21 acpmTRPVLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very low event class." ::= { acpmTRPEntry 22 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.22 acpmTRPSysrepEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting enable for total real power telemetry." ::= { acpmTRPEntry 23 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.23 acpmTRPSysrepThreshold OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting threshold for total real power telemetry. This is a floating point value." ::= { acpmTRPEntry 24 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.24 acpmTRPSysrepLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting limit for total real power telemetry." ::= { acpmTRPEntry 25 } --1.3.6.1.4.1.3052.17.2.12.12.5.1.25 acpmDisconnectTable OBJECT-TYPE SYNTAX SEQUENCE OF ACPMConfigDisconnect MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes AC power monitor device disconnect event attributes." ::= { acPowerMonitor 6 } --1.3.6.1.4.1.3052.17.2.12.12.6 acpmDisconnectEntry OBJECT-TYPE SYNTAX ACPMConfigDisconnect MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for AC power monitor device disconnect event config table." INDEX { acpmDisconnectIndex } ::= { acpmDisconnectTable 1 } --1.3.6.1.4.1.3052.17.2.12.12.6.1 acpmDisconnectIndex OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Which AC power monitor in the AC power monitor device disconnect event config table." ::= { acpmDisconnectEntry 1 } --1.3.6.1.4.1.3052.17.2.12.12.6.1.1 acpmDisconnectEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable AC power monitor device disconnect event." ::= { acpmDisconnectEntry 2 } --1.3.6.1.4.1.3052.17.2.12.12.6.1.2 acpmDisconnectActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for disconnect event." ::= { acpmDisconnectEntry 3 } --1.3.6.1.4.1.3052.17.2.12.12.6.1.3 acpmDisconnectTrapNum OBJECT-TYPE SYNTAX Integer32 (524..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for disconnect event." ::= { acpmDisconnectEntry 4 } --1.3.6.1.4.1.3052.17.2.12.12.6.1.4 acpmDisconnectClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for disconnect event." ::= { acpmDisconnectEntry 5 } --1.3.6.1.4.1.3052.17.2.12.12.6.1.5 acpmDisconnectNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for disconnect return to normal event." ::= { acpmDisconnectEntry 6 } --1.3.6.1.4.1.3052.17.2.12.12.6.1.6 acpmDisconnectNormalTrapNum OBJECT-TYPE SYNTAX Integer32 (524..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for disconnect return to normal event." ::= { acpmDisconnectEntry 7 } --1.3.6.1.4.1.3052.17.2.12.12.6.1.7 acpmDisconnectNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for disconnect return to normal event." ::= { acpmDisconnectEntry 8 } --1.3.6.1.4.1.3052.17.2.12.12.6.1.8 acpmTotalPowerFactorTable OBJECT-TYPE SYNTAX SEQUENCE OF ACPMConfigTotalPowerFactor MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes AC power monitor device total power factor event attributes." ::= { acPowerMonitor 7 } --1.3.6.1.4.1.3052.17.2.12.12.7 acpmTPFEntry OBJECT-TYPE SYNTAX ACPMConfigTotalPowerFactor MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for AC power monitor device total power factor event config table." INDEX { acpmTPFIndex } ::= { acpmTotalPowerFactorTable 1 } --1.3.6.1.4.1.3052.17.2.12.12.7.1 acpmTPFIndex OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Which AC power monitor in the AC power monitor device disconnect event config table." ::= { acpmTPFEntry 1 } --1.3.6.1.4.1.3052.17.2.12.12.7.1.1 acpmTPFEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable AC power monitor device disconnect event." ::= { acpmTPFEntry 2 } --1.3.6.1.4.1.3052.17.2.12.12.7.1.2 acpmTPFDeadband OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Deadband (hysteresis)." ::= { acpmTPFEntry 3 } --1.3.6.1.4.1.3052.17.2.12.12.7.1.3 acpmTPFNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Normal actions." ::= { acpmTPFEntry 4 } --1.3.6.1.4.1.3052.17.2.12.12.7.1.4 acpmTPFNormalTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Normal trap number." ::= { acpmTPFEntry 5 } --1.3.6.1.4.1.3052.17.2.12.12.7.1.5 acpmTPFNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Normal class." ::= { acpmTPFEntry 6 } --1.3.6.1.4.1.3052.17.2.12.12.7.1.6 acpmTPFLowValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low threshold." ::= { acpmTPFEntry 7 } --1.3.6.1.4.1.3052.17.2.12.12.7.1.7 acpmTPFLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low actions." ::= { acpmTPFEntry 8 } --1.3.6.1.4.1.3052.17.2.12.12.7.1.8 acpmTPFLowTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Low trap number." ::= { acpmTPFEntry 9 } --1.3.6.1.4.1.3052.17.2.12.12.7.1.9 acpmTPFLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low class." ::= { acpmTPFEntry 10 } --1.3.6.1.4.1.3052.17.2.12.12.7.1.10 acpmTPFVLowValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very Low threshold." ::= { acpmTPFEntry 11 } --1.3.6.1.4.1.3052.17.2.12.12.7.1.11 acpmTPFVLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very Low actions." ::= { acpmTPFEntry 12 } --1.3.6.1.4.1.3052.17.2.12.12.7.1.12 acpmTPFVLowTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Very Low trap number." ::= { acpmTPFEntry 13 } --1.3.6.1.4.1.3052.17.2.12.12.7.1.13 acpmTPFVLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very Low class." ::= { acpmTPFEntry 14 } --1.3.6.1.4.1.3052.17.2.12.12.7.1.14 acpmTPFSysrepEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting enable." ::= { acpmTPFEntry 15 } --1.3.6.1.4.1.3052.17.2.12.12.7.1.15 acpmTPFSysrepThreshold OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting threshold." ::= { acpmTPFEntry 16 } --1.3.6.1.4.1.3052.17.2.12.12.7.1.16 acpmTPFSysrepLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting limit." ::= { acpmTPFEntry 17 } --1.3.6.1.4.1.3052.17.2.12.12.7.1.17 --*************************************************************************************** --Battery Monitor Config Section 2.12.14 --*************************************************************************************** batteryMonitorGeneralTable OBJECT-TYPE SYNTAX SEQUENCE OF BatteryMonitorConfigGeneral MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes general battery monitor attributes." ::= { batteryMonitor 1 } --1.3.6.1.4.1.3052.17.2.12.14.1 bmGenEntry OBJECT-TYPE SYNTAX BatteryMonitorConfigGeneral MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for battery monitor general config table." INDEX { bmGenIndex } ::= { batteryMonitorGeneralTable 1 } --1.3.6.1.4.1.3052.17.2.12.14.1.1 bmGenIndex OBJECT-TYPE SYNTAX Integer32 (1..9) MAX-ACCESS read-only STATUS current DESCRIPTION "Which battery monitor in the battery monitor general config table." ::= { bmGenEntry 1 } --1.3.6.1.4.1.3052.17.2.12.14.1.1.1 bmGenEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Which battery monitor in the battery monitor general config table." ::= { bmGenEntry 2 } --1.3.6.1.4.1.3052.17.2.12.14.1.1.2 bmGenName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Name for this battery monitor." ::= { bmGenEntry 3 } --1.3.6.1.4.1.3052.17.2.12.14.1.1.3 bmGenBatteryQuantity OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of batteries in the string." ::= { bmGenEntry 4 } --1.3.6.1.4.1.3052.17.2.12.14.1.1.4 bmGenBatteryCapacity OBJECT-TYPE SYNTAX Integer32 (5..500) MAX-ACCESS read-write STATUS current DESCRIPTION "Capacity of the individual batteries in the string, in amp-hours. A single value applies to all batteries; that is, they are assumed to be all of the same capacity." ::= { bmGenEntry 5 } --1.3.6.1.4.1.3052.17.2.12.14.1.1.5 bmGenBatteryNominalVoltage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Nominal voltage of the individual batteries in the string, in volts. A single value applies to all batteres; that is, they are assumed to be all of the same voltage. This is a floating point value." ::= { bmGenEntry 6 } --1.3.6.1.4.1.3052.17.2.12.14.1.1.6 bmGenSysrepPackage OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting package number." ::= { bmGenEntry 7 } --1.3.6.1.4.1.3052.17.2.12.14.1.1.7 bmGenSysrepType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting ASM profile type." ::= { bmGenEntry 8 } --1.3.6.1.4.1.3052.17.2.12.14.1.1.8 batteryMonitorDeviceTable OBJECT-TYPE SYNTAX SEQUENCE OF BatteryMonitorConfigDevice MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes temperature battery monitor attributes." ::= { batteryMonitor 2 } --1.3.6.1.4.1.3052.17.2.12.14.2 bmDeviceEntry OBJECT-TYPE SYNTAX BatteryMonitorConfigDevice MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for battery monitor temperature config table." INDEX { bmDeviceIndex } ::= { batteryMonitorDeviceTable 1 } --1.3.6.1.4.1.3052.17.2.12.14.2.1 bmDeviceIndex OBJECT-TYPE SYNTAX Integer32 (1..9) MAX-ACCESS read-only STATUS current DESCRIPTION "Which battery monitor in the battery monitor device config table." ::= { bmDeviceEntry 1 } --1.3.6.1.4.1.3052.17.2.12.14.2.1.1 bmDeviceType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The type of hardware battery monitor unit associated with this battery monitor." ::= { bmDeviceEntry 2 } --1.3.6.1.4.1.3052.17.2.12.14.2.1.2 bmDeviceES OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-write STATUS current DESCRIPTION "The ES index of the hardware battery monitor unit associated with this battery monitor. This setting only pertains to the ES-BMU." ::= { bmDeviceEntry 3 } --1.3.6.1.4.1.3052.17.2.12.14.2.1.3 bmDeviceIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of the hardware battery monitor unit associated with this battery monitor." ::= { bmDeviceEntry 4 } --1.3.6.1.4.1.3052.17.2.12.14.2.1.4 bmDeviceReadcom OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The SNMP read community of the hardware battery monitor unit associated with this battery monitor." ::= { bmDeviceEntry 5 } --1.3.6.1.4.1.3052.17.2.12.14.2.1.5 bmDeviceInputString OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Which string on the hardware battery monitor unit is associated with this battery monitor. " ::= { bmDeviceEntry 6 } --1.3.6.1.4.1.3052.17.2.12.14.2.1.6 bmDeviceCTSize OBJECT-TYPE SYNTAX Integer32 (0..999) MAX-ACCESS read-write STATUS current DESCRIPTION "The rating of the DC current sensor, in amperes. If this value is set to 0, then string current will not be measured. This setting only pertains to the ES-BMU." ::= { bmDeviceEntry 7 } --1.3.6.1.4.1.3052.17.2.12.14.2.1.7 batteryMonitorTempTable OBJECT-TYPE SYNTAX SEQUENCE OF BatteryMonitorConfigTemp MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes temperature battery monitor attributes." ::= { batteryMonitor 3 } --1.3.6.1.4.1.3052.17.2.12.14.3 bmTempEntry OBJECT-TYPE SYNTAX BatteryMonitorConfigTemp MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for battery monitor temperature config table." INDEX { bmTempIndex } ::= { batteryMonitorTempTable 1 } --1.3.6.1.4.1.3052.17.2.12.14.3.1 bmTempIndex OBJECT-TYPE SYNTAX Integer32 (1..9) MAX-ACCESS read-only STATUS current DESCRIPTION "Which battery monitor in the battery monitor temperature config table." ::= { bmTempEntry 1 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.1 bmTempEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable temperature event. This event is based on the average temperature of the jars in the string." ::= { bmTempEntry 2 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.2 bmTempDeadband OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Deadband in degrees F or C, depending on scale setting of sensor referenced by bmGenDeviceES. This is a floating point value." ::= { bmTempEntry 3 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.3 bmTempScale OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Temperature scale; this affects how temperature values are represented, and also how the temperature alarm thresholds and deadbands are interpreted." ::= { bmTempEntry 4 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.4 bmTempHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event threshold in degrees F or C, depending on scale setting referenced by bmGenDeviceES. This is a floating point value." ::= { bmTempEntry 5 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.5 bmTempHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for very high temperature event." ::= { bmTempEntry 6 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.6 bmTempHighTrapNum OBJECT-TYPE SYNTAX Integer32 (530..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for high temperature event." ::= { bmTempEntry 7 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.7 bmTempHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for high temperature event." ::= { bmTempEntry 8 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.8 bmTempNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for return to normal temperature event." ::= { bmTempEntry 9 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.9 bmTempNormalTrapNum OBJECT-TYPE SYNTAX Integer32 (530..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for return to normal temperature event." ::= { bmTempEntry 10 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.10 bmTempNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for return to normal temperature event." ::= { bmTempEntry 11 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.11 bmTempLowValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event threshold in degrees F or C, depending on scale setting. This is a floating point value." ::= { bmTempEntry 12 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.12 bmTempLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for low temperature event." ::= { bmTempEntry 13 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.13 bmTempLowTrapNum OBJECT-TYPE SYNTAX Integer32 (530..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for low temperature event." ::= { bmTempEntry 14 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.14 bmTempLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for low temperature event." ::= { bmTempEntry 15 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.15 bmTempSysrepEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting enable for temperature telemetry." ::= { bmTempEntry 16 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.16 bmTempSysrepThreshold OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting threshold for temperature telemetry. This is a floating point value." ::= { bmTempEntry 17 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.17 bmTempSysrepLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting limit for temperature telemetry." ::= { bmTempEntry 18 } --1.3.6.1.4.1.3052.17.2.12.14.3.1.18 batteryMonitorDiffTempTable OBJECT-TYPE SYNTAX SEQUENCE OF BatteryMonitorConfigDiffTemp MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes differential temperature battery monitor attributes." ::= { batteryMonitor 4 } --1.3.6.1.4.1.3052.17.2.12.14.4 bmDiffTempEntry OBJECT-TYPE SYNTAX BatteryMonitorConfigDiffTemp MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for battery monitor differential temperature config table." INDEX { bmDiffTempIndex } ::= { batteryMonitorDiffTempTable 1 } --1.3.6.1.4.1.3052.17.2.12.14.4.1 bmDiffTempIndex OBJECT-TYPE SYNTAX Integer32 (1..9) MAX-ACCESS read-only STATUS current DESCRIPTION "Which battery monitor in the battery monitor differential temperature config table." ::= { bmDiffTempEntry 1 } --1.3.6.1.4.1.3052.17.2.12.14.4.1.1 bmDiffTempEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable differential temperature event. This event is based on the differential between the average temperature of the batteries in the string, and ambient temperature (ambient - string temperature)." ::= { bmDiffTempEntry 2 } --1.3.6.1.4.1.3052.17.2.12.14.4.1.2 bmDiffTempDeadband OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Deadband in degrees F or C, depending on scale setting." ::= { bmDiffTempEntry 3 } --1.3.6.1.4.1.3052.17.2.12.14.4.1.3 bmDiffTempVHighValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event threshold in degrees F or C, depending on scale setting." ::= { bmDiffTempEntry 4 } --1.3.6.1.4.1.3052.17.2.12.14.4.1.4 bmDiffTempVHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for very high differential temperature event." ::= { bmDiffTempEntry 5 } --1.3.6.1.4.1.3052.17.2.12.14.4.1.5 bmDiffTempVHighTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for very high differential temperature event." ::= { bmDiffTempEntry 6 } --1.3.6.1.4.1.3052.17.2.12.14.4.1.6 bmDiffTempVHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for very high differential temperature event." ::= { bmDiffTempEntry 7 } --1.3.6.1.4.1.3052.17.2.12.14.4.1.7 bmDiffTempHighValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "High event threshold in degrees F or C, depending on scale setting." ::= { bmDiffTempEntry 8 } --1.3.6.1.4.1.3052.17.2.12.14.4.1.8 bmDiffTempHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for high differential temperature event." ::= { bmDiffTempEntry 9 } --1.3.6.1.4.1.3052.17.2.12.14.4.1.9 bmDiffTempHighTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for high differential temperature event." ::= { bmDiffTempEntry 10 } --1.3.6.1.4.1.3052.17.2.12.14.4.1.10 bmDiffTempHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for high differential temperature event." ::= { bmDiffTempEntry 11 } --1.3.6.1.4.1.3052.17.2.12.14.4.1.11 bmDiffTempNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for return to normal differential temperature event." ::= { bmDiffTempEntry 12 } --1.3.6.1.4.1.3052.17.2.12.14.4.1.12 bmDiffTempNormalTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for return to normal differential temperature event." ::= { bmDiffTempEntry 13 } --1.3.6.1.4.1.3052.17.2.12.14.4.1.13 bmDiffTempNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for return to normal differential temperature event." ::= { bmDiffTempEntry 14 } --1.3.6.1.4.1.3052.17.2.12.14.4.1.14 bmDiffTempSysrepEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting enable for differential temperature telemetry." ::= { bmDiffTempEntry 15 } --1.3.6.1.4.1.3052.17.2.12.14.4.1.15 bmDiffTempSysrepThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting threshold for differential temperature telemetry." ::= { bmDiffTempEntry 16 } --1.3.6.1.4.1.3052.17.2.12.14.4.1.16 bmDiffTempSysrepLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting limit for differential temperature telemetry." ::= { bmDiffTempEntry 17 } --1.3.6.1.4.1.3052.17.2.12.14.4.1.17 batteryMonitorVoltageTable OBJECT-TYPE SYNTAX SEQUENCE OF BatteryMonitorConfigVoltage MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes battery monitor voltage attributes." ::= { batteryMonitor 5 } --1.3.6.1.4.1.3052.17.2.12.14.5 bmVoltageEntry OBJECT-TYPE SYNTAX BatteryMonitorConfigVoltage MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for battery monitor voltage config table." INDEX { bmVoltageIndex } ::= { batteryMonitorVoltageTable 1 } --1.3.6.1.4.1.3052.17.2.12.14.5.1 bmVoltageIndex OBJECT-TYPE SYNTAX Integer32 (1..9) MAX-ACCESS read-only STATUS current DESCRIPTION "Which battery monitor in the battery monitor voltage config table." ::= { bmVoltageEntry 1 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.1 bmVoltageEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable voltage event. This event is based on the total voltage output of the batteries in the string." ::= { bmVoltageEntry 2 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.2 bmVoltageDeadband OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Deadband in volts. This is a floating point value." ::= { bmVoltageEntry 3 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.3 bmVoltageVHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event threshold, in volts. This is a floating point value." ::= { bmVoltageEntry 4 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.4 bmVoltageVHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for very high voltage event." ::= { bmVoltageEntry 5 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.5 bmVoltageVHighTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for very high voltage event." ::= { bmVoltageEntry 6 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.6 bmVoltageVHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for very high voltage event." ::= { bmVoltageEntry 7 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.7 bmVoltageHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event threshold, in volts. This is a floating point value." ::= { bmVoltageEntry 8 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.8 bmVoltageHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for high voltage event." ::= { bmVoltageEntry 9 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.9 bmVoltageHighTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for high voltage event." ::= { bmVoltageEntry 10 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.10 bmVoltageHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for high voltage event." ::= { bmVoltageEntry 11 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.11 bmVoltageNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for return to normal voltage event." ::= { bmVoltageEntry 12 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.12 bmVoltageNormalTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for return to normal voltage event." ::= { bmVoltageEntry 13 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.13 bmVoltageNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for return to normal voltage event." ::= { bmVoltageEntry 14 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.14 bmVoltageLowValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Low event threshold, in volts. This is a floating point value." ::= { bmVoltageEntry 15 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.15 bmVoltageLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for low voltage event." ::= { bmVoltageEntry 16 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.16 bmVoltageLowTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for low voltage event." ::= { bmVoltageEntry 17 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.17 bmVoltageLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for low voltage event." ::= { bmVoltageEntry 18 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.18 bmVoltageVLowValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very Low event threshold, in volts. This is a floating point value." ::= { bmVoltageEntry 19 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.19 bmVoltageVLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for very low voltage event." ::= { bmVoltageEntry 20 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.20 bmVoltageVLowTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for very low voltage event." ::= { bmVoltageEntry 21 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.21 bmVoltageVLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for very low voltage event." ::= { bmVoltageEntry 22 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.22 bmVoltageSysrepEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting enable for voltage telemetry." ::= { bmVoltageEntry 23 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.23 bmVoltageSysrepThreshold OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting threshold for voltage telemetry. This is a floating point value." ::= { bmVoltageEntry 24 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.24 bmVoltageSysrepLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting limit for voltage telemetry." ::= { bmVoltageEntry 25 } --1.3.6.1.4.1.3052.17.2.12.14.5.1.25 batteryMonitorDiffVoltTable OBJECT-TYPE SYNTAX SEQUENCE OF BatteryMonitorConfigDiffVolt MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes differential voltage battery monitor attributes." ::= { batteryMonitor 6 } --1.3.6.1.4.1.3052.17.2.12.14.6 bmDiffVoltEntry OBJECT-TYPE SYNTAX BatteryMonitorConfigDiffVolt MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for battery monitor differential voltage config table." INDEX { bmDiffVoltIndex } ::= { batteryMonitorDiffVoltTable 1 } --1.3.6.1.4.1.3052.17.2.12.14.6.1 bmDiffVoltIndex OBJECT-TYPE SYNTAX Integer32 (1..9) MAX-ACCESS read-only STATUS current DESCRIPTION "Which battery monitor in the battery monitor differential voltage config table." ::= { bmDiffVoltEntry 1 } --1.3.6.1.4.1.3052.17.2.12.14.6.1.1 bmDiffVoltEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable differential voltage event. This event is based on the differential between the highest and lowest jar voltages within the string." ::= { bmDiffVoltEntry 2 } --1.3.6.1.4.1.3052.17.2.12.14.6.1.2 bmDiffVoltDeadband OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Deadband in volts." ::= { bmDiffVoltEntry 3 } --1.3.6.1.4.1.3052.17.2.12.14.6.1.3 bmDiffVoltVHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event threshold in volts. This is a floating point value." ::= { bmDiffVoltEntry 4 } --1.3.6.1.4.1.3052.17.2.12.14.6.1.4 bmDiffVoltVHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for very high differential voltage event." ::= { bmDiffVoltEntry 5 } --1.3.6.1.4.1.3052.17.2.12.14.6.1.5 bmDiffVoltVHighTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for very high differential voltage event." ::= { bmDiffVoltEntry 6 } --1.3.6.1.4.1.3052.17.2.12.14.6.1.6 bmDiffVoltVHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for very high differential voltage event." ::= { bmDiffVoltEntry 7 } --1.3.6.1.4.1.3052.17.2.12.14.6.1.7 bmDiffVoltHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event threshold in volts. This is a floating point value." ::= { bmDiffVoltEntry 8 } --1.3.6.1.4.1.3052.17.2.12.14.6.1.8 bmDiffVoltHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for high differential voltage event." ::= { bmDiffVoltEntry 9 } --1.3.6.1.4.1.3052.17.2.12.14.6.1.9 bmDiffVoltHighTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for high differential voltage event." ::= { bmDiffVoltEntry 10 } --1.3.6.1.4.1.3052.17.2.12.14.6.1.10 bmDiffVoltHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for high differential voltage event." ::= { bmDiffVoltEntry 11 } --1.3.6.1.4.1.3052.17.2.12.14.6.1.11 bmDiffVoltNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for return to normal differential voltage event." ::= { bmDiffVoltEntry 12 } --1.3.6.1.4.1.3052.17.2.12.14.6.1.12 bmDiffVoltNormalTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for return to normal differential voltage event." ::= { bmDiffVoltEntry 13 } --1.3.6.1.4.1.3052.17.2.12.14.6.1.13 bmDiffVoltNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for return to normal differential voltage event." ::= { bmDiffVoltEntry 14 } --1.3.6.1.4.1.3052.17.2.12.14.6.1.14 bmDiffVoltSysrepEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting enable for differential voltage telemetry." ::= { bmDiffVoltEntry 15 } --1.3.6.1.4.1.3052.17.2.12.14.6.1.15 bmDiffVoltSysrepThreshold OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting threshold for differential voltage telemetry." ::= { bmDiffVoltEntry 16 } --1.3.6.1.4.1.3052.17.2.12.14.6.1.16 bmDiffVoltSysrepLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting limit for differential voltage telemetry." ::= { bmDiffVoltEntry 17 } --1.3.6.1.4.1.3052.17.2.12.14.6.1.17 batteryMonitorChargingCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF BatteryMonitorConfigChargingCurrent MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes battery monitor charging current attributes." ::= { batteryMonitor 7 } --1.3.6.1.4.1.3052.17.2.12.14.7 bmChargingCurrentEntry OBJECT-TYPE SYNTAX BatteryMonitorConfigChargingCurrent MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for battery monitor differential charging current config table." INDEX { bmChargingCurrentIndex } ::= { batteryMonitorChargingCurrentTable 1 } --1.3.6.1.4.1.3052.17.2.12.14.7.1 bmChargingCurrentIndex OBJECT-TYPE SYNTAX Integer32 (1..9) MAX-ACCESS read-only STATUS current DESCRIPTION "Which battery monitor in the battery monitor charging current config table." ::= { bmChargingCurrentEntry 1 } --1.3.6.1.4.1.3052.17.2.12.14.7.1.1 bmChargingCurrentEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable charging current event. This event is based on positive current flow (i.e. current flowing into the battery string)." ::= { bmChargingCurrentEntry 2 } --1.3.6.1.4.1.3052.17.2.12.14.7.1.2 bmChargingCurrentDeadband OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Deadband in amperes. This is a floating point value." ::= { bmChargingCurrentEntry 3 } --1.3.6.1.4.1.3052.17.2.12.14.7.1.3 bmChargingCurrentVHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event threshold, in volts. This is a floating point value." ::= { bmChargingCurrentEntry 4 } --1.3.6.1.4.1.3052.17.2.12.14.7.1.4 bmChargingCurrentVHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for very high charging current event." ::= { bmChargingCurrentEntry 5 } --1.3.6.1.4.1.3052.17.2.12.14.7.1.5 bmChargingCurrentVHighTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for very high charging current event." ::= { bmChargingCurrentEntry 6 } --1.3.6.1.4.1.3052.17.2.12.14.7.1.6 bmChargingCurrentVHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for very high charging current event." ::= { bmChargingCurrentEntry 7 } --1.3.6.1.4.1.3052.17.2.12.14.7.1.7 bmChargingCurrentHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event threshold, in volts. This is a floating point value." ::= { bmChargingCurrentEntry 8 } --1.3.6.1.4.1.3052.17.2.12.14.7.1.8 bmChargingCurrentHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for high charging current event." ::= { bmChargingCurrentEntry 9 } --1.3.6.1.4.1.3052.17.2.12.14.7.1.9 bmChargingCurrentHighTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for high charging current event." ::= { bmChargingCurrentEntry 10 } --1.3.6.1.4.1.3052.17.2.12.14.7.1.10 bmChargingCurrentHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for high charging current event." ::= { bmChargingCurrentEntry 11 } --1.3.6.1.4.1.3052.17.2.12.14.7.1.11 bmChargingCurrentNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for return to normal charging current event." ::= { bmChargingCurrentEntry 12 } --1.3.6.1.4.1.3052.17.2.12.14.7.1.12 bmChargingCurrentNormalTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for return to normal charging current event." ::= { bmChargingCurrentEntry 13 } --1.3.6.1.4.1.3052.17.2.12.14.7.1.13 bmChargingCurrentNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for return to normal charging current event." ::= { bmChargingCurrentEntry 14 } --1.3.6.1.4.1.3052.17.2.12.14.7.1.14 bmChargingCurrentSysrepEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting enable for charging current telemetry." ::= { bmChargingCurrentEntry 15 } --1.3.6.1.4.1.3052.17.2.12.14.7.1.15 bmChargingCurrentSysrepThreshold OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting threshold for charging current telemetry. This is a floating point value." ::= { bmChargingCurrentEntry 16 } --1.3.6.1.4.1.3052.17.2.12.14.7.1.16 bmChargingCurrentSysrepLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting limit for charging current telemetry." ::= { bmChargingCurrentEntry 17 } --1.3.6.1.4.1.3052.17.2.12.14.7.1.17 batteryMonitorDischargingCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF BatteryMonitorConfigDischargingCurrent MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes battery monitor discharging current attributes." ::= { batteryMonitor 8 } --1.3.6.1.4.1.3052.17.2.12.14.8 bmDischargingCurrentEntry OBJECT-TYPE SYNTAX BatteryMonitorConfigDischargingCurrent MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for battery monitor differential discharging current config table." INDEX { bmDischargingCurrentIndex } ::= { batteryMonitorDischargingCurrentTable 1 } --1.3.6.1.4.1.3052.17.2.12.14.8.1 bmDischargingCurrentIndex OBJECT-TYPE SYNTAX Integer32 (1..9) MAX-ACCESS read-only STATUS current DESCRIPTION "Which battery monitor in the battery monitor discharging current config table." ::= { bmDischargingCurrentEntry 1 } --1.3.6.1.4.1.3052.17.2.12.14.8.1.1 bmDischargingCurrentEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable discharging current event. This event is based on positive current flow (i.e. current flowing into the battery string)." ::= { bmDischargingCurrentEntry 2 } --1.3.6.1.4.1.3052.17.2.12.14.8.1.2 bmDischargingCurrentDeadband OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Deadband in amperes. This is a floating point value." ::= { bmDischargingCurrentEntry 3 } --1.3.6.1.4.1.3052.17.2.12.14.8.1.3 bmDischargingCurrentVHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Very high event threshold, in volts. This is a floating point value." ::= { bmDischargingCurrentEntry 4 } --1.3.6.1.4.1.3052.17.2.12.14.8.1.4 bmDischargingCurrentVHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for very high discharging current event." ::= { bmDischargingCurrentEntry 5 } --1.3.6.1.4.1.3052.17.2.12.14.8.1.5 bmDischargingCurrentVHighTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for very high discharging current event." ::= { bmDischargingCurrentEntry 6 } --1.3.6.1.4.1.3052.17.2.12.14.8.1.6 bmDischargingCurrentVHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for very high discharging current event." ::= { bmDischargingCurrentEntry 7 } --1.3.6.1.4.1.3052.17.2.12.14.8.1.7 bmDischargingCurrentHighValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "High event threshold, in volts. This is a floating point value." ::= { bmDischargingCurrentEntry 8 } --1.3.6.1.4.1.3052.17.2.12.14.8.1.8 bmDischargingCurrentHighActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for high discharging current event." ::= { bmDischargingCurrentEntry 9 } --1.3.6.1.4.1.3052.17.2.12.14.8.1.9 bmDischargingCurrentHighTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for high discharging current event." ::= { bmDischargingCurrentEntry 10 } --1.3.6.1.4.1.3052.17.2.12.14.8.1.10 bmDischargingCurrentHighClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for high discharging current event." ::= { bmDischargingCurrentEntry 11 } --1.3.6.1.4.1.3052.17.2.12.14.8.1.11 bmDischargingCurrentNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for return to normal discharging current event." ::= { bmDischargingCurrentEntry 12 } --1.3.6.1.4.1.3052.17.2.12.14.8.1.12 bmDischargingCurrentNormalTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for return to normal discharging current event." ::= { bmDischargingCurrentEntry 13 } --1.3.6.1.4.1.3052.17.2.12.14.8.1.13 bmDischargingCurrentNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for return to normal discharging current event." ::= { bmDischargingCurrentEntry 14 } --1.3.6.1.4.1.3052.17.2.12.14.8.1.14 bmDischargingCurrentSysrepEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting enable for discharging current telemetry." ::= { bmDischargingCurrentEntry 15 } --1.3.6.1.4.1.3052.17.2.12.14.8.1.15 bmDischargingCurrentSysrepThreshold OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting threshold for discharging current telemetry. This is a floating point value." ::= { bmDischargingCurrentEntry 16 } --1.3.6.1.4.1.3052.17.2.12.14.8.1.16 bmDischargingCurrentSysrepLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting limit for discharging current telemetry." ::= { bmDischargingCurrentEntry 17 } --1.3.6.1.4.1.3052.17.2.12.14.8.1.17 batteryMonitorChargeLevelTable OBJECT-TYPE SYNTAX SEQUENCE OF BatteryMonitorConfigChargeLevel MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes battery monitor charge level attributes." ::= { batteryMonitor 9 } --1.3.6.1.4.1.3052.17.2.12.14.9 bmChargeLevelEntry OBJECT-TYPE SYNTAX BatteryMonitorConfigChargeLevel MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for battery monitor charge level config table." INDEX { bmChargeLevelIndex } ::= { batteryMonitorChargeLevelTable 1 } --1.3.6.1.4.1.3052.17.2.12.14.9.1 bmChargeLevelIndex OBJECT-TYPE SYNTAX Integer32 (1..9) MAX-ACCESS read-only STATUS current DESCRIPTION "Which battery monitor in the battery monitor charge level config table." ::= { bmChargeLevelEntry 1 } --1.3.6.1.4.1.3052.17.2.12.14.9.1.1 bmChargeLevelEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable charge level event." ::= { bmChargeLevelEntry 2 } --1.3.6.1.4.1.3052.17.2.12.14.9.1.2 bmChargeLevelNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for return to normal charge level event." ::= { bmChargeLevelEntry 3 } --1.3.6.1.4.1.3052.17.2.12.14.9.1.3 bmChargeLevelNormalTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for return to normal charge level event." ::= { bmChargeLevelEntry 4 } --1.3.6.1.4.1.3052.17.2.12.14.9.1.4 bmChargeLevelNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for return to normal charge level event." ::= { bmChargeLevelEntry 5 } --1.3.6.1.4.1.3052.17.2.12.14.9.1.5 bmChargeLevelLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for low charge level event." ::= { bmChargeLevelEntry 6 } --1.3.6.1.4.1.3052.17.2.12.14.9.1.6 bmChargeLevelLowTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for low charge level event." ::= { bmChargeLevelEntry 7 } --1.3.6.1.4.1.3052.17.2.12.14.9.1.7 bmChargeLevelLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for low charge level event." ::= { bmChargeLevelEntry 8 } --1.3.6.1.4.1.3052.17.2.12.14.9.1.8 bmChargeLevelVLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for very low charge level event." ::= { bmChargeLevelEntry 9 } --1.3.6.1.4.1.3052.17.2.12.14.9.1.9 bmChargeLevelVLowTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for very low charge level event." ::= { bmChargeLevelEntry 10 } --1.3.6.1.4.1.3052.17.2.12.14.9.1.10 bmChargeLevelVLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for very low charge level event." ::= { bmChargeLevelEntry 11 } --1.3.6.1.4.1.3052.17.2.12.14.9.1.11 bmChargeLevelSysrepEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting enable for charge level telemetry." ::= { bmChargeLevelEntry 12 } --1.3.6.1.4.1.3052.17.2.12.14.9.1.12 batteryMonitorJarHealthTable OBJECT-TYPE SYNTAX SEQUENCE OF BatteryMonitorConfigJarHealth MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table organizes battery monitor jar health attributes." ::= { batteryMonitor 10 } --1.3.6.1.4.1.3052.17.2.12.14.10 bmJarHealthEntry OBJECT-TYPE SYNTAX BatteryMonitorConfigJarHealth MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for battery monitor jar health config table." INDEX { bmJarHealthIndex } ::= { batteryMonitorJarHealthTable 1 } --1.3.6.1.4.1.3052.17.2.12.14.10.1 bmJarHealthIndex OBJECT-TYPE SYNTAX Integer32 (1..9) MAX-ACCESS read-only STATUS current DESCRIPTION "Which battery monitor in the battery monitor jar health config table." ::= { bmJarHealthEntry 1 } --1.3.6.1.4.1.3052.17.2.12.14.10.1.1 bmJarHealthEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable jar health event." ::= { bmJarHealthEntry 2 } --1.3.6.1.4.1.3052.17.2.12.14.10.1.2 bmJarHealthNormalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for return to normal jar health event." ::= { bmJarHealthEntry 3 } --1.3.6.1.4.1.3052.17.2.12.14.10.1.3 bmJarHealthNormalTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for return to normal jar health event." ::= { bmJarHealthEntry 4 } --1.3.6.1.4.1.3052.17.2.12.14.10.1.4 bmJarHealthNormalClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for return to normal jar health event." ::= { bmJarHealthEntry 5 } --1.3.6.1.4.1.3052.17.2.12.14.10.1.5 bmJarHealthLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for low jar health event." ::= { bmJarHealthEntry 6 } --1.3.6.1.4.1.3052.17.2.12.14.10.1.6 bmJarHealthLowTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for low jar health event." ::= { bmJarHealthEntry 7 } --1.3.6.1.4.1.3052.17.2.12.14.10.1.7 bmJarHealthLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for low jar health event." ::= { bmJarHealthEntry 8 } --1.3.6.1.4.1.3052.17.2.12.14.10.1.8 bmJarHealthVLowActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for very low jar health event." ::= { bmJarHealthEntry 9 } --1.3.6.1.4.1.3052.17.2.12.14.10.1.9 bmJarHealthVLowTrapNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for very low jar health event." ::= { bmJarHealthEntry 10 } --1.3.6.1.4.1.3052.17.2.12.14.10.1.10 bmJarHealthVLowClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class for very low jar health event." ::= { bmJarHealthEntry 11 } --1.3.6.1.4.1.3052.17.2.12.14.10.1.11 bmJarHealthSysrepEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System reporting enable for jar health telemetry." ::= { bmJarHealthEntry 12 } --1.3.6.1.4.1.3052.17.2.12.14.10.1.12 --*************************************************************************************** --Reset Event Section 2.12.16 --*************************************************************************************** evResetEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable reset event. This event is triggered when the unit finishes booting." ::= { evReset 1 } --1.3.6.1.4.1.3052.17.2.12.16.1 evResetDelay OBJECT-TYPE SYNTAX Integer32 (0..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of seconds to wait after unit finishes booting before triggering the reset event." ::= { evReset 2 } --1.3.6.1.4.1.3052.17.2.12.16.2 evResetActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for reset event." ::= { evReset 3 } --1.3.6.1.4.1.3052.17.2.12.16.3 evResetMessage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Message for reset event." ::= { evReset 4 } --1.3.6.1.4.1.3052.17.2.12.16.4 evResetTrapnum OBJECT-TYPE SYNTAX Integer32 (543..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for reset event." ::= { evReset 5 } --1.3.6.1.4.1.3052.17.2.12.16.5 evResetClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class (severity) for reset event." ::= { evReset 6 } --1.3.6.1.4.1.3052.17.2.12.16.6 --*************************************************************************************** --Global Event Section 2.12.18 --*************************************************************************************** evGlobalActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Global event actions." ::= { evGlobal 2 } --1.3.6.1.4.1.3052.17.2.12.18.2 evGlobalTrapnum OBJECT-TYPE SYNTAX Integer32 (0..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Global trap number." ::= { evGlobal 3 } --1.3.6.1.4.1.3052.17.2.12.18.3 --*************************************************************************************** --Action Section 2.14 --*************************************************************************************** actionSchedEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF enable action schedule" ::= { actionSched 1 } --1.3.6.1.4.1.3052.17.2.14.3.1 actionSchedBegin OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "action schedule begin time (HH:MM)" ::= { actionSched 2 } --1.3.6.1.4.1.3052.17.2.14.3.2 actionSchedEnd OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "action schedule end time (HH:MM)" ::= { actionSched 3 } --1.3.6.1.4.1.3052.17.2.14.3.3 actionSchedWeekdaysOnly OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF whether the action schedule applies to weekdays only (ON) or all days (OFF)" ::= { actionSched 4 } --1.3.6.1.4.1.3052.17.2.14.3.4 actionAsentriaRequireAck OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF Asentria action requires an ack from the receiver" ::= { actionAsentria 1 } --1.3.6.1.4.1.3052.17.2.14.4.1 actionAsentriaVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "version 1.0 or 1.1" ::= { actionAsentria 2 } --1.3.6.1.4.1.3052.17.2.14.4.2 actionAsentriaTCPPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "TCP port used for TCP-based Asentria alarms" ::= { actionAsentria 3 } --1.3.6.1.4.1.3052.17.2.14.4.3 actionHostTable OBJECT-TYPE SYNTAX SEQUENCE OF ActionHostConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of network hosts to use for network-based actions" ::= { action 6 } --1.3.6.1.4.1.3052.17.2.14.6 actionHostEntry OBJECT-TYPE SYNTAX ActionHostConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of network hosts to use for network-based actions" INDEX { actionHostIndex } ::= { actionHostTable 1 } --1.3.6.1.4.1.3052.17.2.14.6.1 actionHostIndex OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of network hosts to use for network-based actions" ::= { actionHostEntry 1 } --1.3.6.1.4.1.3052.17.2.14.6.1.1 actionHost OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Hostname/IP address used as destination for network-based action (e.g., trap)" ::= { actionHostEntry 2 } --1.3.6.1.4.1.3052.17.2.14.6.1.2 actionEmailTable OBJECT-TYPE SYNTAX SEQUENCE OF ActionEmailConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of email addresses to use for email actions" ::= { action 7 } --1.3.6.1.4.1.3052.17.2.14.7 actionEmailEntry OBJECT-TYPE SYNTAX ActionEmailConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of email addresses to use for email actions" INDEX { actionEmailIndex } ::= { actionEmailTable 1 } --1.3.6.1.4.1.3052.17.2.14.7.1 actionEmailIndex OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of email addresses to use for email actions" ::= { actionEmailEntry 1 } --1.3.6.1.4.1.3052.17.2.14.7.1.1 actionEmail OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "email address" ::= { actionEmailEntry 2 } --1.3.6.1.4.1.3052.17.2.14.7.1.2 actionParseError OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "When a user attempts to configure an invalid action setting/ object, this object says why it was invalid." ::= { action 8 } --1.3.6.1.4.1.3052.17.2.14.8 --*************************************************************************************** --System Section 2.16 --*************************************************************************************** sysTimeAutoDST OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF automatically adjust for Daylight Savings Time" ::= { sysTime 1 } --1.3.6.1.4.1.3052.17.2.16.1.1 sysTimeGMTOffset OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Absolute value of offset (hours) from GMT of the timezone" ::= { sysTime 2 } --1.3.6.1.4.1.3052.17.2.16.1.2 sysTimeGMTDirection OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Direction (AHEAD/BEHIND) of timezone relative to GMT" ::= { sysTime 3 } --1.3.6.1.4.1.3052.17.2.16.1.3 sysTimeNetEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Network time mode" ::= { sysTimeNet 1 } --1.3.6.1.4.1.3052.17.2.16.1.4.1 sysTimeNetHostTable OBJECT-TYPE SYNTAX SEQUENCE OF NetworkTimeHostConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of hosts to use for network time services" ::= { sysTimeNet 2 } --1.3.6.1.4.1.3052.17.2.16.1.4.2 sysTimeNetHostEntry OBJECT-TYPE SYNTAX NetworkTimeHostConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of hosts to use for network time services" INDEX { sysTimeNetHostIndex } ::= { sysTimeNetHostTable 1 } --1.3.6.1.4.1.3052.17.2.16.1.4.2.1 sysTimeNetHostIndex OBJECT-TYPE SYNTAX Integer32 (1..6) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of hosts to use for network time services" ::= { sysTimeNetHostEntry 1 } --1.3.6.1.4.1.3052.17.2.16.1.4.2.1.1 sysTimeNetHost OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "host to use for network time services" ::= { sysTimeNetHostEntry 2 } --1.3.6.1.4.1.3052.17.2.16.1.4.2.1.2 sysPTTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Timeout (minutes) of inactivity after which a pass-through session is terminated (0 means it never terminates)" ::= { sysPT 1 } --1.3.6.1.4.1.3052.17.2.16.2.1 sysPTEndPause OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "number of 16ths of a second between escape characters received on pass-through origin IO handle that are reuired for the escape characters to register as pass-through escape characters in the pass-through escape sequence. Set to 0 to make the escape character register as part of the pass- through escape sequence without requiring a pause." ::= { sysPT 2 } --1.3.6.1.4.1.3052.17.2.16.2.2 sysMTU OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum transfer unit for ethernet interfaces" ::= { sys 3 } --1.3.6.1.4.1.3052.17.2.16.3 sysAnswerString OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "String displayed upon login" ::= { sys 4 } --1.3.6.1.4.1.3052.17.2.16.4 sysEventFileID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ID string for events file" ::= { sys 6 } --1.3.6.1.4.1.3052.17.2.16.6 sysEscapeCharacter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Decimal ASCII code of the system escape character" ::= { sys 7 } --1.3.6.1.4.1.3052.17.2.16.7 sysTimeStampTimeFormat OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Format of time stamp: HH:MM,HH:MM:SS,BLANK" ::= { sysTimeStamp 1 } --1.3.6.1.4.1.3052.17.2.16.8.1 sysTimeStampDateFormat OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Format of date stamp: MM/DD,MM/DD/YY,MM/DD/YYYY,BLANK" ::= { sysTimeStamp 2 } --1.3.6.1.4.1.3052.17.2.16.8.2 sysTimeStampSpaceAfter OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF Inlude a space after timestamp" ::= { sysTimeStamp 3 } --1.3.6.1.4.1.3052.17.2.16.8.3 sysLogMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Syslog mode: disabled, emit UDP (REMOTE), save in a rotating file set (FILE), or emit on a listening socket (SERVER)" ::= { sysLog 1 } --1.3.6.1.4.1.3052.17.2.16.9.1 sysLoghost OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Syslog host: destination machine when syslog mode is REMOTE" ::= { sysLog 2 } --1.3.6.1.4.1.3052.17.2.16.9.2 sysLogFilter OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "String describing what functions place data in the syslog" ::= { sysLog 3 } --1.3.6.1.4.1.3052.17.2.16.9.3 sysLogFileSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Size (in KB) of syslog files (when syslog mode is SERVER or FILE)" ::= { sysLog 4 } --1.3.6.1.4.1.3052.17.2.16.9.4 sysLogFileCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of files in syslog file set (when syslog mode is SERVER or FILE)" ::= { sysLog 5 } --1.3.6.1.4.1.3052.17.2.16.9.5 sysLogListenPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "TCP port on which the unit listens for a connection on which syslog data is dumped (when syslog mode is SERVER)" ::= { sysLog 6 } --1.3.6.1.4.1.3052.17.2.16.9.6 sysCRDBCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Capacity of Call Record Database (in KB)" ::= { sysCRDB 1 } --1.3.6.1.4.1.3052.17.2.10.1 sysCRDBPercentFull OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of the CRDB used" ::= { sysCRDB 2 } --1.3.6.1.4.1.3052.17.2.10.2 sysCRDBFileIDTable OBJECT-TYPE SYNTAX SEQUENCE OF CRDBFileIDConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of CRDB file IDs" ::= { sysCRDB 3 } --1.3.6.1.4.1.3052.17.2.16.10.3 sysCRDBFileIDEntry OBJECT-TYPE SYNTAX CRDBFileIDConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of CRDB file IDs" INDEX { sysCRDBFileIDIndex } ::= { sysCRDBFileIDTable 1 } --1.3.6.1.4.1.3052.17.2.16.10.3.1 sysCRDBFileIDIndex OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of CRDB file IDs" ::= { sysCRDBFileIDEntry 1 } --1.3.6.1.4.1.3052.17.2.16.10.3.1.1 sysCRDBFileID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ID of CRDB file for this port-associated file x" ::= { sysCRDBFileIDEntry 2 } --1.3.6.1.4.1.3052.17.2.16.10.3.1.2 sysCRDBFileEnforceMinTable OBJECT-TYPE SYNTAX SEQUENCE OF CRDBFileEnforceMinConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of CRDB file minimum size enforcement settings" ::= { sysCRDB 4 } --1.3.6.1.4.1.3052.17.2.16.10.4 sysCRDBFileEnforceMinEntry OBJECT-TYPE SYNTAX CRDBFileEnforceMinConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of CRDB file minimum size enforcement settings" INDEX { sysCRDBFileEnforceMinIndex } ::= { sysCRDBFileEnforceMinTable 1 } --1.3.6.1.4.1.3052.17.2.16.10.4.1 sysCRDBFileEnforceMinIndex OBJECT-TYPE SYNTAX Integer32 (1..24) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of CRDB file minimum size enforcement settings" ::= { sysCRDBFileEnforceMinEntry 1 } --1.3.6.1.4.1.3052.17.2.16.10.4.1.1 sysCRDBFileEnforceMin OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF: enforce minimum size for this CRDB file x" ::= { sysCRDBFileEnforceMinEntry 2 } --1.3.6.1.4.1.3052.17.2.16.10.4.1.2 sysCharMask OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Character mask used for ignoring certain characters on serial ports when assembling data records (when port mode is ASCII)" ::= { sys 11 } --1.3.6.1.4.1.3052.17.2.16.11 sysPrompt OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Prompt to use in a commnand session" ::= { sys 12 } --1.3.6.1.4.1.3052.17.2.16.12 sysBootStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "String describing the boot status of the unit (Booted OK/ still booting" ::= { sys 13 } --1.3.6.1.4.1.3052.17.2.16.13 --*************************************************************************************** --Sys Location Section 2.16.14 --*************************************************************************************** sysLocLatitude OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Latitude portion of geographic coordinates as string" ::= { sysLoc 1 } --1.3.6.1.4.1.3052.17.2.16.14.1 sysLocLongitude OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Longitude portion of geographic coordinates as string" ::= { sysLoc 2 } --1.3.6.1.4.1.3052.17.2.16.14.2 sysLocXOffset OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "X-offset portion of geographic coordinates as string" ::= { sysLoc 3 } --1.3.6.1.4.1.3052.17.2.16.14.3 sysLocYOffset OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Y offset portion of geographic coordinates as string" ::= { sysLoc 4 } --1.3.6.1.4.1.3052.17.2.16.14.4 sysLocAngle OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Angle portion of geographic coordinates as string" ::= { sysLoc 5 } --1.3.6.1.4.1.3052.17.2.16.14.5 sysLocAltitude OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Altitude as string" ::= { sysLoc 6 } --1.3.6.1.4.1.3052.17.2.16.14.6 --*************************************************************************************** --Sys File Transfer Section 2.16.17 --*************************************************************************************** sysFileTransferStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Start/cancel file transfer, or check transfer status. To start, set this object to 'start'. To cancel, set this object to 'cancel'. To check status, get the object" ::= { sysFileTransfer 1 } --1.3.6.1.4.1.3052.17.2.16.17.1 sysFileTransferURL OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "URL (describing protocol, host, directory, and file) on which file transfer function operates." ::= { sysFileTransfer 2 } --1.3.6.1.4.1.3052.17.2.16.17.2 sysFileTransferUsername OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Username for user account at the resource specified by sysFileTransferURL." ::= { sysFileTransfer 3 } --1.3.6.1.4.1.3052.17.2.16.17.3 sysFileTransferPassword OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Password for user account at the resource specified by sysFileTransferURL." ::= { sysFileTransfer 4 } --1.3.6.1.4.1.3052.17.2.16.17.4 --*************************************************************************************** --Sys Update Section 2.16.18 --*************************************************************************************** sysUpdateStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Check time/result of last update attempt." ::= { sysUpdate 1 } --1.3.6.1.4.1.3052.17.2.16.18.1 --*************************************************************************************** --Audit Log Section 2.17 --*************************************************************************************** auditLogEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF enable audit log" ::= { auditLog 1 } --1.3.6.1.4.1.3052.17.2.17.1 auditLogStoreResets OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF audit log stores when the unit resets" ::= { auditLog 2 } --1.3.6.1.4.1.3052.17.2.17.1 auditLogStoreCommands OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF audit log stores commands entered in a command session" ::= { auditLog 3 } --1.3.6.1.4.1.3052.17.2.17.1 auditLogStoreRelays OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF audit log stores relay activity" ::= { auditLog 4 } --1.3.6.1.4.1.3052.17.2.17.1 auditLogStoreAlarmActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF audit log stores action delivery activity" ::= { auditLog 5 } --1.3.6.1.4.1.3052.17.2.17.1 auditLogStorePwdFailures OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF audit log stores when user was denied login" ::= { auditLog 6 } --1.3.6.1.4.1.3052.17.2.17.1 auditLogStoreLogins OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF audit log stores when a user was allowed login" ::= { auditLog 7 } --1.3.6.1.4.1.3052.17.2.17.1 auditLogStoreSHSK OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF audit log stores serial handshaking status (regardless of serial handshaking event)" ::= { auditLog 8 } --1.3.6.1.4.1.3052.17.2.17.1 auditLogStorePassthrough OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF audit log stores pass-through activity" ::= { auditLog 9 } --1.3.6.1.4.1.3052.17.2.17.1 auditLogStoreInactivity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF audit log stores when sessions expire due to inactivity" ::= { auditLog 10 } --1.3.6.1.4.1.3052.17.2.17.1 auditLogStorePolling OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF audit log stores CRDB polling activity" ::= { auditLog 11 } --1.3.6.1.4.1.3052.17.2.17.1 auditLogMaxSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum size (in KB) of audit log" ::= { auditLog 12 } --1.3.6.1.4.1.3052.17.2.17.1 --*************************************************************************************** --Scripting Section 2.17 --*************************************************************************************** scrGlobalEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF enable scripting" ::= { scripting 1 } --1.3.6.1.4.1.3052.17.2.18.1 scrDTRCtrlPortEnableTable OBJECT-TYPE SYNTAX SEQUENCE OF ScriptingDTRCtrlPortEnableConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of DTR control port enables" ::= { scripting 2 } --1.3.6.1.4.1.3052.17.2.18.2 scrDTRCtrlPortEnableEntry OBJECT-TYPE SYNTAX ScriptingDTRCtrlPortEnableConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of DTR control port enables" INDEX { scrDTRCtrlPortEnableIndex } ::= { scrDTRCtrlPortEnableTable 1 } --1.3.6.1.4.1.3052.17.2.18.2.1 scrDTRCtrlPortEnableIndex OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of DTR control port enables" ::= { scrDTRCtrlPortEnableEntry 1 } --1.3.6.1.4.1.3052.17.2.18.2.1.1 scrDTRCtrlPortEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF enable DTR control of scripting for this port" ::= { scrDTRCtrlPortEnableEntry 2 } --1.3.6.1.4.1.3052.17.2.18.2.1.2 scrTable OBJECT-TYPE SYNTAX SEQUENCE OF ScriptingConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of scripts" ::= { scripting 3 } --1.3.6.1.4.1.3052.17.2.18.3 scrEntry OBJECT-TYPE SYNTAX ScriptingConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of scripts" INDEX { scrIndex } ::= { scrTable 1 } --1.3.6.1.4.1.3052.17.2.18.3.1 scrIndex OBJECT-TYPE SYNTAX Integer32 (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of scripts" ::= { scrEntry 1 } --1.3.6.1.4.1.3052.17.2.18.3.1.1 scrEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF enable this script" ::= { scrEntry 2 } --1.3.6.1.4.1.3052.17.2.18.3.1.2 scrName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Name of this script" ::= { scrEntry 3 } --1.3.6.1.4.1.3052.17.2.18.3.1.3 scrFilename OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Filename for this script" ::= { scrEntry 4 } --1.3.6.1.4.1.3052.17.2.18.3.1.4 scrRunAlways OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF: this script always runs" ::= { scrEntry 5 } --1.3.6.1.4.1.3052.17.2.18.3.1.5 scrRunAtStartup OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF: this script runs at startup" ::= { scrEntry 6 } --1.3.6.1.4.1.3052.17.2.18.3.1.6 scrRunScheduled OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "ON/OFF: this script runs at a certain time of day" ::= { scrEntry 7 } --1.3.6.1.4.1.3052.17.2.18.3.1.7 scrScheduleTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Time of day (HH:MM) this script is scheduled to run" ::= { scrEntry 8 } --1.3.6.1.4.1.3052.17.2.18.3.1.8 scrArguments OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Arguments for this script" ::= { scrEntry 9 } --1.3.6.1.4.1.3052.17.2.18.3.1.9 scrRepeatInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "How often this script runs (minutes)" ::= { scrEntry 10 } --1.3.6.1.4.1.3052.17.2.18.3.1.10 scrVolatileStringTable OBJECT-TYPE SYNTAX SEQUENCE OF ScriptingVolatileString MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of volatile string settings for use in scripts." ::= { scripting 4 } --1.3.6.1.4.1.3052.17.2.18.4 scrVolatileStringEntry OBJECT-TYPE SYNTAX ScriptingVolatileString MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of volatile script string settings" INDEX { scrVolatileStringIndex } ::= { scrVolatileStringTable 1 } --1.3.6.1.4.1.3052.17.2.18.4.1 scrVolatileStringIndex OBJECT-TYPE SYNTAX Integer32 (1..50) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of volatile script string settings" ::= { scrVolatileStringEntry 1 } --1.3.6.1.4.1.3052.17.2.18.4.1.1 scrVolatileString OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Volatile string for use in scripts. Use this object to cache frequently-changing string values or string values that do not need to persist through reset. This object corresponds to the scripting.vstring[] setting key branch; use those keys in scripts and you can view or change their values with this object." ::= { scrVolatileStringEntry 2 } --1.3.6.1.4.1.3052.17.2.18.4.1.2 scrVolatileIntTable OBJECT-TYPE SYNTAX SEQUENCE OF ScriptingVolatileInt MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of volatile integer settings for use in scripts." ::= { scripting 5 } --1.3.6.1.4.1.3052.17.2.18.5 scrVolatileIntEntry OBJECT-TYPE SYNTAX ScriptingVolatileInt MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of volatile script integer settings" INDEX { scrVolatileIntIndex } ::= { scrVolatileIntTable 1 } --1.3.6.1.4.1.3052.17.2.18.5.1 scrVolatileIntIndex OBJECT-TYPE SYNTAX Integer32 (1..50) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of volatile script integer settings" ::= { scrVolatileIntEntry 1 } --1.3.6.1.4.1.3052.17.2.18.5.1.1 scrVolatileInt OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Volatile integer for use in scripts. Use this object to cache frequently-changing integer values or integer values that do not need to persist through reset. This object corresponds to the scripting.vint[] setting key branch; use those keys in scripts and you can view or change their values with this object." ::= { scrVolatileIntEntry 2 } --1.3.6.1.4.1.3052.17.2.18.5.1.2 scrNonVolatileStringTable OBJECT-TYPE SYNTAX SEQUENCE OF ScriptingNonVolatileString MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of non-volatile string settings for use in scripts." ::= { scripting 6 } --1.3.6.1.4.1.3052.17.2.18.6 scrNonVolatileStringEntry OBJECT-TYPE SYNTAX ScriptingNonVolatileString MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of non-volatile script string settings" INDEX { scrNonVolatileStringIndex } ::= { scrNonVolatileStringTable 1 } --1.3.6.1.4.1.3052.17.2.18.6.1 scrNonVolatileStringIndex OBJECT-TYPE SYNTAX Integer32 (1..50) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of non-volatile script string settings" ::= { scrNonVolatileStringEntry 1 } --1.3.6.1.4.1.3052.17.2.18.6.1.1 scrNonVolatileString OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Non-volatile string for use in scripts. Use this object to store values that need to persist through reset. This object corresponds to the scripting.nvstring[] setting key branch; use those keys in scripts and you can view or change their values with this object. Note: to store frequently- changing integers, use the scrVolatileString object, otherwise your scripts may cause unnecessary wear of the non-volatile storage medium on the unit." ::= { scrNonVolatileStringEntry 2 } --1.3.6.1.4.1.3052.17.2.18.6.1.2 scrNonVolatileIntTable OBJECT-TYPE SYNTAX SEQUENCE OF ScriptingNonVolatileInt MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of non-volatile integer settings for use in scripts." ::= { scripting 7 } --1.3.6.1.4.1.3052.17.2.18.7 scrNonVolatileIntEntry OBJECT-TYPE SYNTAX ScriptingNonVolatileInt MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of non-volatile script integer settings" INDEX { scrNonVolatileIntIndex } ::= { scrNonVolatileIntTable 1 } --1.3.6.1.4.1.3052.17.2.18.7.1 scrNonVolatileIntIndex OBJECT-TYPE SYNTAX Integer32 (1..50) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of non-volatile script integer settings" ::= { scrNonVolatileIntEntry 1 } --1.3.6.1.4.1.3052.17.2.18.7.1.1 scrNonVolatileInt OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Non-volatile integer for use in scripts. Use this object to store integer values that need to persist through reset. This object corresponds to the scripting.nvint[] setting key branch; use those keys in scripts and you can view or change their values with this object. Note: to store frequently- changing integers, use the scrVolatileInt object, otherwise your scripts may cause unnecessary wear of the non-volatile storage medium on the unit." ::= { scrNonVolatileIntEntry 2 } --1.3.6.1.4.1.3052.17.2.18.7.1.2 --*************************************************************************************** --Generator Section 2.19 --*************************************************************************************** genSetEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable genset functionality; that is, a generator is in use." ::= { genSet 1 } --1.3.6.1.4.1.3052.17.2.19.1.1 genSetRelayEs OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-write STATUS current DESCRIPTION "Which EventSensor has the relay which starts the generator." ::= { genSetRelay 1 } --1.3.6.1.4.1.3052.17.2.19.1.2.1 genSetRelayPoint OBJECT-TYPE SYNTAX Integer32 (1..13) MAX-ACCESS read-write STATUS current DESCRIPTION "Which relay starts the generator." ::= { genSetRelay 2 } --1.3.6.1.4.1.3052.17.2.19.1.2.2 genSetRelayRunningstate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Which relay state corresponds with the generator starting/running." ::= { genSetRelay 3 } --1.3.6.1.4.1.3052.17.2.19.1.2.3 genSetCCEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable generator running detection functionality; that is, the associated CC is valid for determining if generator is running." ::= { genSetCC 1 } --1.3.6.1.4.1.3052.17.2.19.1.3.1 genSetCCEs OBJECT-TYPE SYNTAX Integer32 (1..200) MAX-ACCESS read-write STATUS current DESCRIPTION "Which CC EventSensor has the CC which is connected to the genertor running detection monitor." ::= { genSetCC 2 } --1.3.6.1.4.1.3052.17.2.19.1.3.2 genSetCCPoint OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-write STATUS current DESCRIPTION "Which CC is connected to the genertor running detection monitor." ::= { genSetCC 3 } --1.3.6.1.4.1.3052.17.2.19.1.3.3 genSetCCRunningState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Which CC physical state corresponds with the generator running." ::= { genSetCC 4 } --1.3.6.1.4.1.3052.17.2.19.1.3.4 genRunMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Generator Exercising function main operating mode; set to INHIBIT to inhibit exercising the generator." ::= { genRun 1 } --1.3.6.1.4.1.3052.17.2.19.2.1 genRunSched OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Schedule number(s) which govern(s) when Generator Exercising function runs." ::= { genRun 2 } --1.3.6.1.4.1.3052.17.2.19.2.2 genRunDuration OBJECT-TYPE SYNTAX Integer32 (600..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of seconds that generator should run, started when the generator needs to start by SCHEDULE or by being forced to start." ::= { genRun 3 } --1.3.6.1.4.1.3052.17.2.19.2.3 genRunForce OBJECT-TYPE SYNTAX Integer32 (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Write 1 to this to force the generator exercising to start. Always reads as 0." ::= { genRun 4 } --1.3.6.1.4.1.3052.17.2.19.2.4 genRunReqasm OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Require ASM connectivity before starting the generator from a schedule." ::= { genRun 5 } --1.3.6.1.4.1.3052.17.2.19.2.5 genRunStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Status of Generator Exercising function." ::= { genRun 6 } --1.3.6.1.4.1.3052.17.2.19.2.6 genRunNonstartEventEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable generator non-start event." ::= { genRunNonstartEvent 1 } --1.3.6.1.4.1.3052.17.2.19.2.7.1 genRunNonstartEventActions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Actions for generator non-start event." ::= { genRunNonstartEvent 2 } --1.3.6.1.4.1.3052.17.2.19.2.7.2 genRunNonstartEventTrap OBJECT-TYPE SYNTAX Integer32 (536..1199) MAX-ACCESS read-write STATUS current DESCRIPTION "Trap number for generator non-start event." ::= { genRunNonstartEvent 3 } --1.3.6.1.4.1.3052.17.2.19.2.7.3 genRunNonstartEventClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Class (severity) for generator non-start event." ::= { genRunNonstartEvent 4 } --1.3.6.1.4.1.3052.17.2.19.2.7.4 --*************************************************************************************** --Calendar Section 2.20 --*************************************************************************************** schedTable OBJECT-TYPE SYNTAX SEQUENCE OF ScheduleConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of schedules" ::= { calendar 1 } --1.3.6.1.4.1.3052.17.2.20.1 schedEntry OBJECT-TYPE SYNTAX ScheduleConfig MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for table of schedules." INDEX { schedIndex } ::= { schedTable 1 } --1.3.6.1.4.1.3052.17.2.20.1.1 schedIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table of schedules." ::= { schedEntry 1 } --1.3.6.1.4.1.3052.17.2.20.1.1.1 schedEnable OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enable this schedule." ::= { schedEntry 2 } --1.3.6.1.4.1.3052.17.2.20.1.1.2 schedStart OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is of the form 'mm/dd/yy hh:mm:ss'. This controls on which date/time the schedule starts." ::= { schedEntry 3 } --1.3.6.1.4.1.3052.17.2.20.1.1.3 schedRepeatMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Controls in which way the schedule should repeat." ::= { schedEntry 4 } --1.3.6.1.4.1.3052.17.2.20.1.1.4 schedRepeatFreq OBJECT-TYPE SYNTAX Integer32 (1..400) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls how often the schedule should repeat: every nth day, week, month, or year." ::= { schedEntry 5 } --1.3.6.1.4.1.3052.17.2.20.1.1.5 schedRepeatEndMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Controls how the repeating schedule should end." ::= { schedEntry 6 } --1.3.6.1.4.1.3052.17.2.20.1.1.6 schedRepeatEndAfter OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of times this schedule should be repeated; relevant when the repeat end mode is AFTER." ::= { schedEntry 7 } --1.3.6.1.4.1.3052.17.2.20.1.1.7 schedRepeatEndOn OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Date/time (in the form 'mm/yy/dd hh:mm:ss' or blank string) after which repeating should end, relevant when repeat end mode is ON DATE." ::= { schedEntry 8 } --1.3.6.1.4.1.3052.17.2.20.1.1.8 schedRepeatWeeklySun OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule on Sunday(s); relevant when repeat mode is weekly." ::= { schedEntry 9 } --1.3.6.1.4.1.3052.17.2.20.1.1.9 schedRepeatWeeklyMon OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule on Monday(s); relevant when repeat mode is weekly." ::= { schedEntry 10 } --1.3.6.1.4.1.3052.17.2.20.1.1.10 schedRepeatWeeklyTue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule on Tuesday(s); relevant when repeat mode is weekly." ::= { schedEntry 11 } --1.3.6.1.4.1.3052.17.2.20.1.1.11 schedRepeatWeeklyWed OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule on Wednesday(s); relevant when repeat mode is weekly." ::= { schedEntry 12 } --1.3.6.1.4.1.3052.17.2.20.1.1.12 schedRepeatWeeklyThu OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule on Thursday(s); relevant when repeat mode is weekly." ::= { schedEntry 13 } --1.3.6.1.4.1.3052.17.2.20.1.1.13 schedRepeatWeeklyFri OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule on Friday(s); relevant when repeat mode is weekly." ::= { schedEntry 14 } --1.3.6.1.4.1.3052.17.2.20.1.1.14 schedRepeatWeeklySat OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule on Saturday(s); relevant when repeat mode is weekly." ::= { schedEntry 15 } --1.3.6.1.4.1.3052.17.2.20.1.1.15 schedRepeatMonthlyMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "EACH means the schedule runs on specific dates of the month. ON THE means the schedule runs on calculated dates of the month according to which day that month starts." ::= { schedEntry 16 } --1.3.6.1.4.1.3052.17.2.20.1.1.16 schedRepeatMonthlyDates OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Comma-separated list of dates of a month on which this schedule should run, relevant when repeat monthly mode is EACH." ::= { schedEntry 17 } --1.3.6.1.4.1.3052.17.2.20.1.1.17 schedRepeatMonthlyOnThe OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Controls on which day of the month this schedule should run, relevant when repeat monthly mode is ON THE." ::= { schedEntry 18 } --1.3.6.1.4.1.3052.17.2.20.1.1.18 schedRepeatMonthlyOnDay OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the day of week on which this schedule is run, relevant when repeat monthly mode is ON THE" ::= { schedEntry 19 } --1.3.6.1.4.1.3052.17.2.20.1.1.19 schedRepeatYearlyJan OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule in January, relevant when repeat mode is YEARLY." ::= { schedEntry 20 } --1.3.6.1.4.1.3052.17.2.20.1.1.20 schedRepeatYearlyFeb OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule in February, relevant when repeat mode is YEARLY." ::= { schedEntry 21 } --1.3.6.1.4.1.3052.17.2.20.1.1.21 schedRepeatYearlyMar OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule in March, relevant when repeat mode is YEARLY." ::= { schedEntry 22 } --1.3.6.1.4.1.3052.17.2.20.1.1.22 schedRepeatYearlyApr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule in April, relevant when repeat mode is YEARLY." ::= { schedEntry 23 } --1.3.6.1.4.1.3052.17.2.20.1.1.23 schedRepeatYearlyMay OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule in May, relevant when repeat mode is YEARLY." ::= { schedEntry 24 } --1.3.6.1.4.1.3052.17.2.20.1.1.24 schedRepeatYearlyJun OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule in June, relevant when repeat mode is YEARLY." ::= { schedEntry 25 } --1.3.6.1.4.1.3052.17.2.20.1.1.25 schedRepeatYearlyJul OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule in July, relevant when repeat mode is YEARLY." ::= { schedEntry 26 } --1.3.6.1.4.1.3052.17.2.20.1.1.26 schedRepeatYearlyAug OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule in August, relevant when repeat mode is YEARLY." ::= { schedEntry 27 } --1.3.6.1.4.1.3052.17.2.20.1.1.27 schedRepeatYearlySep OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule in September, relevant when repeat mode is YEARLY." ::= { schedEntry 28 } --1.3.6.1.4.1.3052.17.2.20.1.1.28 schedRepeatYearlyOct OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule in October, relevant when repeat mode is YEARLY." ::= { schedEntry 29 } --1.3.6.1.4.1.3052.17.2.20.1.1.29 schedRepeatYearlyNov OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule in November, relevant when repeat mode is YEARLY." ::= { schedEntry 30 } --1.3.6.1.4.1.3052.17.2.20.1.1.30 schedRepeatYearlyDec OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Run this schedule in December, relevant when repeat mode is YEARLY." ::= { schedEntry 31 } --1.3.6.1.4.1.3052.17.2.20.1.1.31 schedRepeatYearlyOnThe OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Controls on which day of the month this schedule should run, relevant when repeat mode is YEARLY." ::= { schedEntry 32 } --1.3.6.1.4.1.3052.17.2.20.1.1.32 schedRepeatYearlyOnDay OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the day of week on which this schedule is run, relevant when repeat mode is YEARLY." ::= { schedEntry 33 } --1.3.6.1.4.1.3052.17.2.20.1.1.33 schedNextTrigger OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "When this schedule will next trigger." ::= { schedEntry 34 } --1.3.6.1.4.1.3052.17.2.20.1.1.34 --*************************************************************************************** --Product IDs Section 3 --*************************************************************************************** siteName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Site Name string; Max 40 characters." ::= { productIds 1 } --1.3.6.1.4.1.3052.17.3.1 thisProduct OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is a factory configured string for the product name." ::= { productIds 2 } --1.3.6.1.4.1.3052.17.3.2 stockTrapString OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The message defined for the event that triggers a trap." ::= { productIds 3 } --1.3.6.1.4.1.3052.17.3.3 trapEventTypeNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined trap variable for the type of event that happened. Here are the definitions: 4 SCHEDULED 7 Serial Handshaking Low 8 Serial Handshaking High 10 Contact Closure Active 11 Contact Closure Inactive 12 Temperature High 13 Temperature Very High 14 Temperature Low 15 Temperature Very Low 16 Temperature Return to Normal 17 Humidity High 18 Humidity Very High 19 Humidity Low 20 Humidity Very Low 21 Humidity Return to Normal 26 Analog High 27 Analog Very High 28 Analog Low 29 Analog Very Low 30 Analog Normal 40 EventSensor Unresponsive 100 Contact Closure Active Reminder 101 Temperature High Reminder 102 Temperature High Very Reminder 103 Temperature Low Reminder 104 Temperature Very Low Reminder 105 Humidity High Reminder 106 Humidity Very High Reminder 107 Humidity Low Reminder 108 Humidity Very Low Reminder 109 Analog High Reminder 110 Analog Very High Reminder 111 Analog Low Reminder 112 Analog Very Low Reminder" ::= { productIds 4 } --1.3.6.1.4.1.3052.17.3.4 trapEventTypeName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined trap variable for the string corresponding to the event type." ::= { productIds 5 } --1.3.6.1.4.1.3052.17.3.5 trapIncludedValue OBJECT-TYPE SYNTAX Integer32 (-2147483648..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined trap variable for the generic included value." ::= { productIds 6 } --1.3.6.1.4.1.3052.17.3.6 trapIncludedString OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined trap variable for the generic included string." ::= { productIds 7 } --1.3.6.1.4.1.3052.17.3.7 trapTypeString OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The cause of the trap, added for DL880 compatibility." ::= { productIds 8 } --1.3.6.1.4.1.3052.17.3.8 trapEventClassNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined trap variable for the configurable class number associated with the triggering event." ::= { productIds 9 } --1.3.6.1.4.1.3052.17.3.9 trapEventClassName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined trap variable for the configurable class name associated with the class number." ::= { productIds 10 } --1.3.6.1.4.1.3052.17.3.10 --*************************************************************************************** --Key Interface Section 4 --*************************************************************************************** keyInterface OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object represents a setting key interface. When setting this object, the value to set is the 'sk' command you would enter on the command line (without the 'sk'). To get the result of the operation, read this object after you write it. For example, to configure EventSensor 1 contact closure 34 event actions to be an SNMP InformRequest to host foo, set this object to: 'event.sensor[1].cc[34].eventactions=inform(foo)'. The SNMP response is the result of the operation: if setting that key to that value was a success then the SNMP response will be a success and the response value will be what you had set. If you subsequently read this object then you will see a message 'OK: ...'. If setting that key to that value failed then the SNMP response will be a failure (a badValue response). If you subsequently read this object then the value returned is the reason that setting that key to that value failed. For another example, to read user 3's pass-through access for port 7, set this object to: 'sec.user[3].port[7].ptaccess'. The SNMP response is the result of the operation: if reading that key is a success then the SNMP response will be a success and the response value will be what you had SET (i.e., the opertion of reading a key, which is just the key itself with no '=' operator, and this is not the key value you want to read). If you subsequently read this object then the value returned is the value of the key you want to read. If reading that key failed (e.g., if the key is invalid) then the SNMP response to your SNMP set operation (the value you set being the invalid key to read) will be a failure (a badValue response). If you subsequently read this object then the value returned is the reason that reading that key failed (i.e., 'invalid key')." ::= { s450 4 } --1.3.6.1.4.1.3052.17.4 --*************************************************************************************** --TABLE DEFINITIONS --*************************************************************************************** ESPointConfigTemp ::= SEQUENCE { espcTempIndexES Integer32, espcTempIndexPoint Integer32, espcTempEnable DisplayString, espcTempScale DisplayString, espcTempDeadband DisplayString, espcTempVHighTemp DisplayString, espcTempVHighActions DisplayString, espcTempVHighTrapnum Integer32, espcTempVHighClass DisplayString, espcTempHighTemp DisplayString, espcTempHighActions DisplayString, espcTempHighTrapnum Integer32, espcTempHighClass DisplayString, espcTempNormalActions DisplayString, espcTempNormalTrapnum Integer32, espcTempNormalClass DisplayString, espcTempLowTemp DisplayString, espcTempLowActions DisplayString, espcTempLowTrapnum Integer32, espcTempLowClass DisplayString, espcTempVLowTemp DisplayString, espcTempVLowActions DisplayString, espcTempVLowTrapnum Integer32, espcTempVLowClass DisplayString } ESPointConfigCC ::= SEQUENCE { espcCCIndexES Integer32, espcCCIndexPoint Integer32, espcCCEnable DisplayString, espcCCName DisplayString, espcCCEventState DisplayString, espcCCThreshold Integer32, espcCCEventActions DisplayString, espcCCEventTrapnum Integer32, espcCCEventClass DisplayString, espcCCNormalActions DisplayString, espcCCNormalTrapnum Integer32, espcCCNormalClass DisplayString, espcCCAlarmAlias DisplayString, espcCCNormalAlias DisplayString, espcCCNormalThreshold Integer32 } ESPointConfigHumid ::= SEQUENCE { espcHumidIndexES Integer32, espcHumidIndexPoint Integer32, espcHumidEnable DisplayString, espcHumidDeadband Integer32, espcHumidVHighHumid Integer32, espcHumidVHighActions DisplayString, espcHumidVHighTrapnum Integer32, espcHumidVHighClass DisplayString, espcHumidHighHumid Integer32, espcHumidHighActions DisplayString, espcHumidHighTrapnum Integer32, espcHumidHighClass DisplayString, espcHumidNormalActions DisplayString, espcHumidNormalTrapnum Integer32, espcHumidNormalClass DisplayString, espcHumidLowHumid Integer32, espcHumidLowActions DisplayString, espcHumidLowTrapnum Integer32, espcHumidLowClass DisplayString, espcHumidVLowHumid Integer32, espcHumidVLowActions DisplayString, espcHumidVLowTrapnum Integer32, espcHumidVLowClass DisplayString } ESPointConfigAnalogInput ::= SEQUENCE { espcAIIndexES Integer32, espcAIIndexPoint Integer32, espcAIEnable DisplayString, espcAIPolarity DisplayString, espcAIDeadband Integer32, espcAIVhighValue Integer32, espcAIVhighActions DisplayString, espcAIVhighTrapnum Integer32, espcAIVhighClass DisplayString, espcAIHighValue Integer32, espcAIHighActions DisplayString, espcAIHighTrapnum Integer32, espcAIHighClass DisplayString, espcAINormalActions DisplayString, espcAINormalTrapnum Integer32, espcAINormalClass DisplayString, espcAILowValue Integer32, espcAILowActions DisplayString, espcAILowTrapnum Integer32, espcAILowClass DisplayString, espcAIVlowValue Integer32, espcAIVlowActions DisplayString, espcAIVlowTrapnum Integer32, espcAIVlowClass DisplayString, espcAIConvUnitName DisplayString, espcAIConvHighValue Integer32, espcAIConvHighUnit Integer32, espcAIConvHighSign DisplayString, espcAIConvLowValue Integer32, espcAIConvLowUnit Integer32, espcAIConvLowSign DisplayString } EventClassConfig ::= SEQUENCE { evClassNameIndex Integer32, evClassName DisplayString } RTSFileConfig ::= SEQUENCE { rtsFileIndex Integer32, rtsFileMode DisplayString, rtsFileShowAnswer DisplayString, rtsFileReqXON DisplayString, rtsFileTimeout Integer32, rtsFileEmptyClose DisplayString, rtsFilePushHost DisplayString, rtsFilePushPort Integer32, rtsFilePushRetryTimer Integer32 } ScriptingConfig ::= SEQUENCE { scrIndex Integer32, scrEnable DisplayString, scrName DisplayString, scrFilename DisplayString, scrRunAlways DisplayString, scrRunAtStartup DisplayString, scrRunScheduled DisplayString, scrScheduleTime DisplayString, scrArguments DisplayString, scrRepeatInterval Integer32 } ScriptingDTRCtrlPortEnableConfig ::= SEQUENCE { scrDTRCtrlPortEnableIndex Integer32, scrDTRCtrlPortEnable DisplayString } ScriptingVolatileString ::= SEQUENCE { scrVolatileStringIndex Integer32, scrVolatileString DisplayString } ScriptingVolatileInt ::= SEQUENCE { scrVolatileIntIndex Integer32, scrVolatileInt Integer32 } ScriptingNonVolatileString ::= SEQUENCE { scrNonVolatileStringIndex Integer32, scrNonVolatileString DisplayString } ScriptingNonVolatileInt ::= SEQUENCE { scrNonVolatileIntIndex Integer32, scrNonVolatileInt Integer32 } CRDBFileEnforceMinConfig ::= SEQUENCE { sysCRDBFileEnforceMinIndex Integer32, sysCRDBFileEnforceMin DisplayString } CRDBFileIDConfig ::= SEQUENCE { sysCRDBFileIDIndex Integer32, sysCRDBFileID DisplayString } NetworkTimeHostConfig ::= SEQUENCE { sysTimeNetHostIndex Integer32, sysTimeNetHost DisplayString } ActionHostConfig ::= SEQUENCE { actionHostIndex Integer32, actionHost DisplayString } ActionEmailConfig ::= SEQUENCE { actionEmailIndex Integer32, actionEmail DisplayString } FileEnforceMinimumConfig ::= SEQUENCE { sysCRDBFileEnforceMinIndex Integer32, sysCRDBFileEnforceMin DisplayString } SerialHandshakingLowEventConfig ::= SEQUENCE { evShskLowIndex Integer32, evShskLowEnable DisplayString, evShskLowActions DisplayString, evShskLowMessage DisplayString, evShskLowClass DisplayString, evShskLowTrapNum Integer32 } SerialHandshakingHighEventConfig ::= SEQUENCE { evShskHighIndex Integer32, evShskHighEnable DisplayString, evShskHighActions DisplayString, evShskHighMessage DisplayString, evShskHighClass DisplayString, evShskHighTrapNum Integer32 } SecUserConfig ::= SEQUENCE { secUserIndex Integer32, secUserEnable DisplayString, secUserConnectVia DisplayString, secUserLoginTo DisplayString, secUserAccessFile DisplayString, secUserPTEscapeTo DisplayString, secUserPPPType DisplayString, secUserRights DisplayString, secUserEventsReadAccess DisplayString, secUserAuditReadAccess DisplayString, secUserEventsWriteAccess DisplayString, secUserAuditWriteAccess DisplayString, secUserExpiration DisplayString, secUserCallbackNumber1 DisplayString, secUserCallbackNumber2 DisplayString, secUserCallbackNumber3 DisplayString, secUserChallengeTelnetMode DisplayString, secUserChallengeModemMode DisplayString, secUserChallengeConsoleMode DisplayString, secUserChallengeTelnetSendTo DisplayString, secUserChallengeModemSendTo DisplayString, secUserChallengeExpiration Integer32 } IPRestrictionConfig ::= SEQUENCE { ipRestrictionIndex Integer32, ipRestrictionEnable DisplayString, ipRestrictionMask IpAddress } DNSConfig ::= SEQUENCE { dnsIndex Integer32, dnsAddress IpAddress } HostConfig ::= SEQUENCE { hostIndex Integer32, hostDeclaration DisplayString } SNMPProxyTable ::= SEQUENCE { snmpProxyIndex Integer32, snmpProxyOIDBranch DisplayString, snmpProxyIP DisplayString, snmpProxyPort Integer32 } SNMPPollRequestConfig ::= SEQUENCE { snmpPRequestIndex Integer32, snmpPRequestDescription DisplayString, snmpPRequestAgent DisplayString, snmpPRequestReadcom DisplayString, snmpPRequestOID DisplayString, snmpPRequestPeriod Integer32, snmpPRequestResultStatus DisplayString, snmpPRequestResultValue DisplayString, snmpPRequestResultTime DisplayString, snmpPRequestResultType DisplayString } FTPPushPushFileConfig ::= SEQUENCE { ftpPushPushFileIndex Integer32, ftpPushPushFile DisplayString } FTPPushRemoteFileConfig ::= SEQUENCE { ftpPushRemoteFileIndex Integer32, ftpPushRemoteFileName DisplayString } PortConfig ::= SEQUENCE { portConfigIndex Integer32, portConfigBaud Integer32, portConfigDataFormat Integer32, portConfigStripPtOutputLfs Integer32, portConfigStripPtInputLfs Integer32, portConfigMaskEnable Integer32, portConfigDAEnable Integer32, portConfigStoreAlarmsDPT DisplayString, portConfigRecordTimeout Integer32, portConfigDataType DisplayString, portConfigEtxToCRLF DisplayString, portConfigMLREnable DisplayString, portConfigMLRStartField1Pos Integer32, portConfigMLRStartField1Text DisplayString, portConfigMLRStartField2Pos Integer32, portConfigMLRStartField2Text DisplayString, portConfigMLRNumLinesBefore Integer32, portConfigMLREndDetection DisplayString, portConfigMLRLineCount Integer32, portConfigMLREndField1Pos Integer32, portConfigMLREndField1Text DisplayString, portConfigMLREndField2Pos Integer32, portConfigMLREndField2Text DisplayString, portConfigMLRUseComplexRules DisplayString, portConfigBufferPT DisplayString, portConfigId DisplayString } ESPoint ::= SEQUENCE { esIndexES Integer32, esIndexPC Integer32, esIndexPoint Integer32, esPointName DisplayString, esPointInEventState Integer32, esPointValueInt Integer32, esPointValueStr DisplayString, esPointTimeLastChange DisplayString, esPointTimetickLastChange TimeTicks, esPointAliasValueStr DisplayString } ESExist ::= SEQUENCE { esIndex Integer32, esName DisplayString, esID DisplayString, esNumberTempSensors Integer32, esTempReportingMode DisplayString, esNumberCCs Integer32, esCCReportingMode DisplayString, esNumberHumidSensors Integer32, esHumidReportingMode DisplayString, esNumberNoiseSensors Integer32, esNoiseReportingMode DisplayString, esNumberAirflowSensors Integer32, esAirflowReportingMode DisplayString, esNumberAnalog Integer32, esAnalogReportingMode DisplayString, esNumberRelayOutputs Integer32, esRelayReportingMode DisplayString, esTempCombinedStatus DisplayString, esCCCombinedStatusBlock1 DisplayString, esCCCombinedStatusBlock2 DisplayString, esCCCombinedStatusBlock3 DisplayString, esCCCombinedStatusBlock4 DisplayString, esCCCombinedStatusBlock5 DisplayString, esCCCombinedStatusBlock6 DisplayString, esCCCombinedStatusBlock7 DisplayString, esCCCombinedStatusBlock8 DisplayString, esHumidCombinedStatus DisplayString, esAnalogCombinedStatusBlock1 DisplayString, esAnalogCombinedStatusBlock2 DisplayString, esAnalogCombinedStatusBlock3 DisplayString, esAnalogCombinedStatusBlock4 DisplayString, esAnalogCombinedStatusBlock5 DisplayString, esAnalogCombinedStatusBlock6 DisplayString, esOutputCombinedStatusBlock1 DisplayString, esOutputCombinedStatusBlock2 DisplayString } DEStatus ::= SEQUENCE { deStatusIndex Integer32, deStatusName DisplayString, deStatusCounter Integer32, deStatusThreshold Integer32 } FSStatus ::= SEQUENCE { fsStatusIndex Integer32, fsStatusName DisplayString, fsStatusDeviceState DisplayString, fsStatusVolumeValueString DisplayString, fsStatusVolumePercentLevel DisplayString, fsStatusVolumeInEventState DisplayString, fsStatusCombined DisplayString } ACPMStatus ::= SEQUENCE { acpmsIndex Integer32, acpmsName DisplayString, acpmsAvgVoltageValueStr DisplayString, acpmsAvgVoltageMinStr DisplayString, acpmsAvgVoltageMaxStr DisplayString, acpmsAvgVoltageAvgStr DisplayString, acpmsAvgVoltageInEventState DisplayString, acpmsVoltagePhaseAValueStr DisplayString, acpmsVoltagePhaseBValueStr DisplayString, acpmsVoltagePhaseCValueStr DisplayString, acpmsAvgCurrentValueStr DisplayString, acpmsAvgCurrentMinStr DisplayString, acpmsAvgCurrentMaxStr DisplayString, acpmsAvgCurrentAvgStr DisplayString, acpmsAvgCurrentInEventState DisplayString, acpmsCurrentPhaseAValueStr DisplayString, acpmsCurrentPhaseBValueStr DisplayString, acpmsCurrentPhaseCValueStr DisplayString, acpmsAvgFreqValueStr DisplayString, acpmsAvgFreqMinStr DisplayString, acpmsAvgFreqMaxStr DisplayString, acpmsAvgFreqAvgStr DisplayString, acpmsAvgFreqInEventState DisplayString, acpmsTRPValueStr DisplayString, acpmsTRPMinStr DisplayString, acpmsTRPMaxStr DisplayString, acpmsTRPAvgStr DisplayString, acpmsTRPInEventState DisplayString, acpmsRPPhaseAValueStr DisplayString, acpmsRPPhaseBValueStr DisplayString, acpmsRPPhaseCValueStr DisplayString, acpmsCombined DisplayString, acpmsTPFValueStr DisplayString, acpmsTPFMinStr DisplayString, acpmsTPFMaxStr DisplayString, acpmsTPFAvgStr DisplayString, acpmsTPFInEventState DisplayString, acpmsPFPhaseAValueStr DisplayString, acpmsPFPhaseBValueStr DisplayString, acpmsPFPhaseCValueStr DisplayString, acpmsTRcPValueStr DisplayString, acpmsTRcPMinStr DisplayString, acpmsTRcPMaxStr DisplayString, acpmsTRcPAvgStr DisplayString, acpmsRcPPhaseAValueStr DisplayString, acpmsRcPPhaseBValueStr DisplayString, acpmsRcPPhaseCValueStr DisplayString, acpmsTAPValueStr DisplayString, acpmsTAPMinStr DisplayString, acpmsTAPMaxStr DisplayString, acpmsTAPAvgStr DisplayString, acpmsAPPhaseAValueStr DisplayString, acpmsAPPhaseBValueStr DisplayString, acpmsAPPhaseCValueStr DisplayString, acpmsTotalEnergyWh Integer32, acpmsTotalEnergyVAR Integer32, acpmsTotalEnergyVA Integer32 } ScheduleConfig ::= SEQUENCE { schedIndex Integer32, schedEnable DisplayString, schedStart DisplayString, schedRepeatMode DisplayString, schedRepeatFreq Integer32, schedRepeatEndMode DisplayString, schedRepeatEndAfter Integer32, schedRepeatEndOn DisplayString, schedRepeatWeeklySun DisplayString, schedRepeatWeeklyMon DisplayString, schedRepeatWeeklyTue DisplayString, schedRepeatWeeklyWed DisplayString, schedRepeatWeeklyThu DisplayString, schedRepeatWeeklyFri DisplayString, schedRepeatWeeklySat DisplayString, schedRepeatMonthlyMode DisplayString, schedRepeatMonthlyDates DisplayString, schedRepeatMonthlyOnThe DisplayString, schedRepeatMonthlyOnDay DisplayString, schedRepeatYearlyJan DisplayString, schedRepeatYearlyFeb DisplayString, schedRepeatYearlyMar DisplayString, schedRepeatYearlyApr DisplayString, schedRepeatYearlyMay DisplayString, schedRepeatYearlyJun DisplayString, schedRepeatYearlyJul DisplayString, schedRepeatYearlyAug DisplayString, schedRepeatYearlySep DisplayString, schedRepeatYearlyOct DisplayString, schedRepeatYearlyNov DisplayString, schedRepeatYearlyDec DisplayString, schedRepeatYearlyOnThe DisplayString, schedRepeatYearlyOnDay DisplayString, schedNextTrigger DisplayString } FuelSensorConfigGeneral ::= SEQUENCE { fsGenIndex Integer32, fsGenName DisplayString, fsGenSensorType DisplayString, fsGenDistanceUnit DisplayString, fsGenRawValueTop Integer32, fsGenTopOffset DisplayString, fsGenRawValueBottom Integer32, fsGenBottomOffset DisplayString, fsGenInputES Integer32, fsGenInputPoint Integer32, fsGenFilterAveraging Integer32, fsGenSysrepEnable DisplayString, fsGenSysrepThreshold DisplayString, fsGenSysrepLimit Integer32, fsGenSysrepPackage Integer32, fsGenSysrepType DisplayString } FuelSensorConfigTank ::= SEQUENCE { fsTankIndex Integer32, fsTankHeight DisplayString, fsTankDimA DisplayString, fsTankDimB DisplayString, fsTankVolume DisplayString, fsTankVolumeUnit DisplayString, fsTankShape DisplayString } FuelSensorConfigCustomTankStrapping ::= SEQUENCE { fsCustomTankIndexFS Integer32, fsCustomTankIndexDatum Integer32, fsCustomTankHeight DisplayString, fsCustomTankVolume DisplayString } FuelSensorConfigVolume ::= SEQUENCE { fsVolumeIndex Integer32, fsVolumeEnable DisplayString, fsVolumeDeadband DisplayString, fsVolumeVHighValue DisplayString, fsVolumeVHighActions DisplayString, fsVolumeVHighTrapNum Integer32, fsVolumeVHighClass DisplayString, fsVolumeHighValue DisplayString, fsVolumeHighActions DisplayString, fsVolumeHighTrapNum Integer32, fsVolumeHighClass DisplayString, fsVolumeNormalActions DisplayString, fsVolumeNormalTrapNum Integer32, fsVolumeNormalClass DisplayString, fsVolumeLowValue DisplayString, fsVolumeLowActions DisplayString, fsVolumeLowTrapNum Integer32, fsVolumeLowClass DisplayString, fsVolumeVLowValue DisplayString, fsVolumeVLowActions DisplayString, fsVolumeVLowTrapNum Integer32, fsVolumeVLowClass DisplayString } FuelSensorConfigDisconnect ::= SEQUENCE { fsDiscIndex Integer32, fsDiscEnable DisplayString, fsDiscHighValue Integer32, fsDiscLowValue Integer32, fsDiscActions DisplayString, fsDiscTrapNum Integer32, fsDiscClass DisplayString, fsDiscNormalActions DisplayString, fsDiscNormalTrapNum Integer32, fsDiscNormalClass DisplayString } FuelSensorConfigSuddenChange ::= SEQUENCE { fsSuddenChangeIndex Integer32, fsSuddenChangeEnable DisplayString, fsSuddenChangeTime Integer32, fsSuddenChangeAmplitude DisplayString, fsSuddenChangeActions DisplayString, fsSuddenChangeTrapNum Integer32, fsSuddenChangeClass DisplayString } FuelSensorConfigSlowChange ::= SEQUENCE { fsSlowChangeIndex Integer32, fsSlowChangeEnable DisplayString, fsSlowChangeTime Integer32, fsSlowChangeAmplitude DisplayString, fsSlowChangeActions DisplayString, fsSlowChangeTrapNum Integer32, fsSlowChangeClass DisplayString } ACPMConfigGeneral ::= SEQUENCE { acpmGenIndex Integer32, acpmGenDevice DisplayString, acpmGenName DisplayString, acpmGenAddress Integer32, acpmGenPtRatio Integer32, acpmGenCtRatio Integer32, acpmGenPowerType DisplayString, acpmGenSysrepPackage Integer32, acpmGenSysrepType DisplayString } ACPMConfigAvgVoltage ::= SEQUENCE { acpmAvgVoltageIndex Integer32, acpmAvgVoltageEnable DisplayString, acpmAvgVoltageDeadband DisplayString, acpmAvgVoltageVHighValue DisplayString, acpmAvgVoltageVHighActions DisplayString, acpmAvgVoltageVHighTrapNum Integer32, acpmAvgVoltageVHighClass DisplayString, acpmAvgVoltageHighValue DisplayString, acpmAvgVoltageHighActions DisplayString, acpmAvgVoltageHighTrapNum Integer32, acpmAvgVoltageHighClass DisplayString, acpmAvgVoltageNormalActions DisplayString, acpmAvgVoltageNormalTrapNum Integer32, acpmAvgVoltageNormalClass DisplayString, acpmAvgVoltageLowValue DisplayString, acpmAvgVoltageLowActions DisplayString, acpmAvgVoltageLowTrapNum Integer32, acpmAvgVoltageLowClass DisplayString, acpmAvgVoltageVLowValue DisplayString, acpmAvgVoltageVLowActions DisplayString, acpmAvgVoltageVLowTrapNum Integer32, acpmAvgVoltageVLowClass DisplayString, acpmAvgVoltageSysrepEnable DisplayString, acpmAvgVoltageSysrepThreshold DisplayString, acpmAvgVoltageSysrepLimit Integer32 } ACPMConfigAvgCurrent ::= SEQUENCE { acpmAvgCurrentIndex Integer32, acpmAvgCurrentEnable DisplayString, acpmAvgCurrentDeadband DisplayString, acpmAvgCurrentVHighValue DisplayString, acpmAvgCurrentVHighActions DisplayString, acpmAvgCurrentVHighTrapNum Integer32, acpmAvgCurrentVHighClass DisplayString, acpmAvgCurrentHighValue DisplayString, acpmAvgCurrentHighActions DisplayString, acpmAvgCurrentHighTrapNum Integer32, acpmAvgCurrentHighClass DisplayString, acpmAvgCurrentNormalActions DisplayString, acpmAvgCurrentNormalTrapNum Integer32, acpmAvgCurrentNormalClass DisplayString, acpmAvgCurrentLowValue DisplayString, acpmAvgCurrentLowActions DisplayString, acpmAvgCurrentLowTrapNum Integer32, acpmAvgCurrentLowClass DisplayString, acpmAvgCurrentVLowValue DisplayString, acpmAvgCurrentVLowActions DisplayString, acpmAvgCurrentVLowTrapNum Integer32, acpmAvgCurrentVLowClass DisplayString, acpmAvgCurrentSysrepEnable DisplayString, acpmAvgCurrentSysrepThreshold DisplayString, acpmAvgCurrentSysrepLimit Integer32 } ACPMConfigFreq ::= SEQUENCE { acpmFreqIndex Integer32, acpmFreqEnable DisplayString, acpmFreqDeadband DisplayString, acpmFreqVHighValue DisplayString, acpmFreqVHighActions DisplayString, acpmFreqVHighTrapNum Integer32, acpmFreqVHighClass DisplayString, acpmFreqHighValue DisplayString, acpmFreqHighActions DisplayString, acpmFreqHighTrapNum Integer32, acpmFreqHighClass DisplayString, acpmFreqNormalActions DisplayString, acpmFreqNormalTrapNum Integer32, acpmFreqNormalClass DisplayString, acpmFreqLowValue DisplayString, acpmFreqLowActions DisplayString, acpmFreqLowTrapNum Integer32, acpmFreqLowClass DisplayString, acpmFreqVLowValue DisplayString, acpmFreqVLowActions DisplayString, acpmFreqVLowTrapNum Integer32, acpmFreqVLowClass DisplayString, acpmFreqSysrepEnable DisplayString, acpmFreqSysrepThreshold DisplayString, acpmFreqSysrepLimit Integer32 } ACPMConfigTRP ::= SEQUENCE { acpmTRPIndex Integer32, acpmTRPEnable DisplayString, acpmTRPDeadband DisplayString, acpmTRPVHighValue DisplayString, acpmTRPVHighActions DisplayString, acpmTRPVHighTrapNum Integer32, acpmTRPVHighClass DisplayString, acpmTRPHighValue DisplayString, acpmTRPHighActions DisplayString, acpmTRPHighTrapNum Integer32, acpmTRPHighClass DisplayString, acpmTRPNormalActions DisplayString, acpmTRPNormalTrapNum Integer32, acpmTRPNormalClass DisplayString, acpmTRPLowValue DisplayString, acpmTRPLowActions DisplayString, acpmTRPLowTrapNum Integer32, acpmTRPLowClass DisplayString, acpmTRPVLowValue DisplayString, acpmTRPVLowActions DisplayString, acpmTRPVLowTrapNum Integer32, acpmTRPVLowClass DisplayString, acpmTRPSysrepEnable DisplayString, acpmTRPSysrepThreshold DisplayString, acpmTRPSysrepLimit Integer32 } ACPMConfigDisconnect ::= SEQUENCE { acpmDisconnectIndex Integer32, acpmDisconnectEnable DisplayString, acpmDisconnectActions DisplayString, acpmDisconnectTrapNum Integer32, acpmDisconnectClass DisplayString, acpmDisconnectNormalActions DisplayString, acpmDisconnectNormalTrapNum Integer32, acpmDisconnectNormalClass DisplayString } ACPMConfigTotalPowerFactor ::= SEQUENCE { acpmTPFIndex Integer32, acpmTPFEnable DisplayString, acpmTPFDeadband DisplayString, acpmTPFNormalActions DisplayString, acpmTPFNormalTrapNum Integer32, acpmTPFNormalClass DisplayString, acpmTPFLowValue DisplayString, acpmTPFLowActions DisplayString, acpmTPFLowTrapNum Integer32, acpmTPFLowClass DisplayString, acpmTPFVLowValue DisplayString, acpmTPFVLowActions DisplayString, acpmTPFVLowTrapNum Integer32, acpmTPFVLowClass DisplayString, acpmTPFSysrepEnable DisplayString, acpmTPFSysrepThreshold DisplayString, acpmTPFSysrepLimit Integer32 } BatteryMonitorConfigGeneral ::= SEQUENCE { bmGenIndex Integer32, bmGenEnable DisplayString, bmGenName DisplayString, bmGenBatteryQuantity Integer32, bmGenBatteryCapacity Integer32, bmGenBatteryNominalVoltage DisplayString, bmGenSysrepPackage Integer32, bmGenSysrepType DisplayString } BatteryMonitorConfigDevice ::= SEQUENCE { bmDeviceIndex Integer32, bmDeviceType DisplayString, bmDeviceES Integer32, bmDeviceIP IpAddress, bmDeviceReadcom DisplayString, bmDeviceInputString Integer32, bmDeviceCTSize Integer32 } BatteryMonitorConfigTemp ::= SEQUENCE { bmTempIndex Integer32, bmTempEnable DisplayString, bmTempDeadband DisplayString, bmTempScale DisplayString, bmTempHighValue DisplayString, bmTempHighActions DisplayString, bmTempHighTrapNum Integer32, bmTempHighClass DisplayString, bmTempNormalActions DisplayString, bmTempNormalTrapNum Integer32, bmTempNormalClass DisplayString, bmTempLowValue DisplayString, bmTempLowActions DisplayString, bmTempLowTrapNum Integer32, bmTempLowClass DisplayString, bmTempSysrepEnable DisplayString, bmTempSysrepThreshold DisplayString, bmTempSysrepLimit Integer32 } BatteryMonitorConfigDiffTemp ::= SEQUENCE { bmDiffTempIndex Integer32, bmDiffTempEnable DisplayString, bmDiffTempDeadband Integer32, bmDiffTempVHighValue Integer32, bmDiffTempVHighActions DisplayString, bmDiffTempVHighTrapNum Integer32, bmDiffTempVHighClass DisplayString, bmDiffTempHighValue Integer32, bmDiffTempHighActions DisplayString, bmDiffTempHighTrapNum Integer32, bmDiffTempHighClass DisplayString, bmDiffTempNormalActions DisplayString, bmDiffTempNormalTrapNum Integer32, bmDiffTempNormalClass DisplayString, bmDiffTempSysrepEnable DisplayString, bmDiffTempSysrepThreshold Integer32, bmDiffTempSysrepLimit Integer32 } BatteryMonitorConfigVoltage ::= SEQUENCE { bmVoltageIndex Integer32, bmVoltageEnable DisplayString, bmVoltageDeadband DisplayString, bmVoltageVHighValue DisplayString, bmVoltageVHighActions DisplayString, bmVoltageVHighTrapNum Integer32, bmVoltageVHighClass DisplayString, bmVoltageHighValue DisplayString, bmVoltageHighActions DisplayString, bmVoltageHighTrapNum Integer32, bmVoltageHighClass DisplayString, bmVoltageNormalActions DisplayString, bmVoltageNormalTrapNum Integer32, bmVoltageNormalClass DisplayString, bmVoltageLowValue DisplayString, bmVoltageLowActions DisplayString, bmVoltageLowTrapNum Integer32, bmVoltageLowClass DisplayString, bmVoltageVLowValue DisplayString, bmVoltageVLowActions DisplayString, bmVoltageVLowTrapNum Integer32, bmVoltageVLowClass DisplayString, bmVoltageSysrepEnable DisplayString, bmVoltageSysrepThreshold DisplayString, bmVoltageSysrepLimit Integer32 } BatteryMonitorConfigDiffVolt ::= SEQUENCE { bmDiffVoltIndex Integer32, bmDiffVoltEnable DisplayString, bmDiffVoltDeadband DisplayString, bmDiffVoltVHighValue DisplayString, bmDiffVoltVHighActions DisplayString, bmDiffVoltVHighTrapNum Integer32, bmDiffVoltVHighClass DisplayString, bmDiffVoltHighValue DisplayString, bmDiffVoltHighActions DisplayString, bmDiffVoltHighTrapNum Integer32, bmDiffVoltHighClass DisplayString, bmDiffVoltNormalActions DisplayString, bmDiffVoltNormalTrapNum Integer32, bmDiffVoltNormalClass DisplayString, bmDiffVoltSysrepEnable DisplayString, bmDiffVoltSysrepThreshold DisplayString, bmDiffVoltSysrepLimit Integer32 } BatteryMonitorConfigChargingCurrent ::= SEQUENCE { bmChargingCurrentIndex Integer32, bmChargingCurrentEnable DisplayString, bmChargingCurrentDeadband DisplayString, bmChargingCurrentVHighValue DisplayString, bmChargingCurrentVHighActions DisplayString, bmChargingCurrentVHighTrapNum Integer32, bmChargingCurrentVHighClass DisplayString, bmChargingCurrentHighValue DisplayString, bmChargingCurrentHighActions DisplayString, bmChargingCurrentHighTrapNum Integer32, bmChargingCurrentHighClass DisplayString, bmChargingCurrentNormalActions DisplayString, bmChargingCurrentNormalTrapNum Integer32, bmChargingCurrentNormalClass DisplayString, bmChargingCurrentSysrepEnable DisplayString, bmChargingCurrentSysrepThreshold DisplayString, bmChargingCurrentSysrepLimit Integer32 } BatteryMonitorConfigDischargingCurrent ::= SEQUENCE { bmDischargingCurrentIndex Integer32, bmDischargingCurrentEnable DisplayString, bmDischargingCurrentDeadband DisplayString, bmDischargingCurrentVHighValue DisplayString, bmDischargingCurrentVHighActions DisplayString, bmDischargingCurrentVHighTrapNum Integer32, bmDischargingCurrentVHighClass DisplayString, bmDischargingCurrentHighValue DisplayString, bmDischargingCurrentHighActions DisplayString, bmDischargingCurrentHighTrapNum Integer32, bmDischargingCurrentHighClass DisplayString, bmDischargingCurrentNormalActions DisplayString, bmDischargingCurrentNormalTrapNum Integer32, bmDischargingCurrentNormalClass DisplayString, bmDischargingCurrentSysrepEnable DisplayString, bmDischargingCurrentSysrepThreshold DisplayString, bmDischargingCurrentSysrepLimit Integer32 } BatteryMonitorConfigChargeLevel ::= SEQUENCE { bmChargeLevelIndex Integer32, bmChargeLevelEnable DisplayString, bmChargeLevelNormalActions DisplayString, bmChargeLevelNormalTrapNum Integer32, bmChargeLevelNormalClass DisplayString, bmChargeLevelLowActions DisplayString, bmChargeLevelLowTrapNum Integer32, bmChargeLevelLowClass DisplayString, bmChargeLevelVLowActions DisplayString, bmChargeLevelVLowTrapNum Integer32, bmChargeLevelVLowClass DisplayString, bmChargeLevelSysrepEnable DisplayString } BatteryMonitorConfigJarHealth ::= SEQUENCE { bmJarHealthIndex Integer32, bmJarHealthEnable DisplayString, bmJarHealthNormalActions DisplayString, bmJarHealthNormalTrapNum Integer32, bmJarHealthNormalClass DisplayString, bmJarHealthLowActions DisplayString, bmJarHealthLowTrapNum Integer32, bmJarHealthLowClass DisplayString, bmJarHealthVLowActions DisplayString, bmJarHealthVLowTrapNum Integer32, bmJarHealthVLowClass DisplayString, bmJarHealthSysrepEnable DisplayString } BMStatus ::= SEQUENCE { bmsIndex Integer32, bmsEnable DisplayString, bmsName DisplayString, bmsState DisplayString, bmsStringState DisplayString, bmsTempValue DisplayString, bmsTempValueStr DisplayString, bmsTempEvent DisplayString, bmsDiffTempValue Integer32, bmsDiffTempValueStr DisplayString, bmsDiffTempEvent DisplayString, bmsVoltageValue DisplayString, bmsVoltageEvent DisplayString, bmsDiffVoltValue DisplayString, bmsDiffVoltEvent DisplayString, bmsCurrentValue DisplayString, bmsChargingCurrentEvent DisplayString, bmsDischargingCurrentEvent DisplayString, bmsChargeLevelValue DisplayString, bmsChargeLevelEvent DisplayString, bmsJarHealthValue DisplayString, bmsJarHealthEvent DisplayString, bmsCombined DisplayString } BMJarStatus ::= SEQUENCE { bmjsIndexBM Integer32, bmjsIndexJar Integer32, bmjsVoltageValue DisplayString, bmjsTempValue DisplayString, bmjsAdmittanceValue Integer32, bmjsAdmittanceChangeValue Integer32 } --*************************************************************************************** --TRAP DEFINITIONS --*************************************************************************************** s450StockContactClosureTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock contact closure trap is issued when a contact closure event happens." ::= { s450notifications 110 } s450StockTempTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock temperature trap is issued when a temperature event happens." ::= { s450notifications 120 } s450StockHumidityTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock humidity trap is issued when a humidity event happens." ::= { s450notifications 130 } s450StockAnalogTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock analog trap is issued when an analog sensor event happens." ::= { s450notifications 140 } s450StockOutputTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock output trap is issued when an output event happens. That is, depending on the configuration, when an output changes state for any reason, this trap will be sent." ::= { s450notifications 150 } s450StockSchedTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "The stock scheduled alarm trap is issued when the current time reaches the scheduled alarm time." ::= { s450notifications 506 } s450StockImmediateTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "The stock immediate alarm trap is issued when the user enters the DOTRAP command." ::= { s450notifications 507 } s450StockCTSTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock CTS trap is issued when an RS-232 CTS event happens." ::= { s450notifications 510 } s450CPEDownTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock CPE Down trap is issued when a CPE Down event happens." ::= { s450notifications 511 } s450FuelSensorDisconnectTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock Fuel Sensor Disconnect trap is issued when a Fuel Sensor Disconnect or Connect (Return to Normal) event happens." ::= { s450notifications 515 } s450FuelSensorVolumeTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock Fuel Sensor Volume trap is issued when a Fuel Sensor Volume event happens" ::= { s450notifications 519 } s450ACPowerMonitorAvgVoltageTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock AC power monitor average voltage trap is issued when an AC power monitor average voltage event happens." ::= { s450notifications 520 } s450ACPowerMonitorAvgCurrentTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock AC power monitor average current trap is issued when an AC power monitor average current event happens." ::= { s450notifications 521 } s450ACPowerMonitorFrequencyTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock AC power monitor frequency trap is issued when an AC power monitor frequency event happens." ::= { s450notifications 522 } s450ACPowerMonitorTRPTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock AC power monitor TRP (total real power) trap is issued when an AC power monitor TRP event happens." ::= { s450notifications 523 } s450ACPowerMonitorDisconnectTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock AC power monitor disconnect trap is issued when an AC power monitor disconnect event happens." ::= { s450notifications 524 } s450StockScriptTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock script trap is issued when a script triggers an event via a_lib.PostEvent() called with no trap number (or this trap number) specified." ::= { s450notifications 526 } s450FuelSensorVolumeSuddenChangeTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock Fuel Sensor Volume Sudden Change trap is issued when a Fuel Sensor Volume Sudden Change event happens" ::= { s450notifications 527 } s450FuelSensorVolumeSlowChangeTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock Fuel Sensor Volume Slow Change trap is issued when a Fuel Sensor Volume Slow Change event happens" ::= { s450notifications 528 } s450BattMonStringTemperatureTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock Battery Monitor String Temperature trap is issued when a Battery Monitor String Temperature event happens." ::= { s450notifications 530 } s450BattMonStringDiffTemperatureTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock Battery Monitor String Differential Temperature trap is issued when a Battery Monitor String Differential Temperature event happens." ::= { s450notifications 531 } s450BattMonStringVoltageTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock Battery Monitor String Voltage trap is issued when a Battery Monitor String Voltage event happens." ::= { s450notifications 532 } s450BattMonStringChargeLevelTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock Battery Monitor String Charge Level trap is issued when a Battery Monitor String Charge Level event happens." ::= { s450notifications 533 } s450BattMonStringChargingCurrentTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock Battery Monitor String Charging Current trap is issued when a Battery Monitor String Charging Current event happens." ::= { s450notifications 534 } s450BattMonStringDischargingCurrentTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock Battery Monitor String Discharging Current trap is issued when a Battery Monitor String Discharging Current event happens." ::= { s450notifications 535 } s450GeneratorNonStartTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock Generator Non-start trap is issued when the unit commands the generator to start as part of the generator exercising feature, and the generator fails to register as started after 30 seconds (as detected by CC generator running detection)." ::= { s450notifications 536 } s450BattMonStringDifferentialVoltageTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock Battery Monitor String Differential Voltage trap is issued when a Battery Monitor String Differential Voltage event happens." ::= { s450notifications 537 } s450BattMonStringJarHealthTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock Battery Monitor String Jar Health trap is issued when a Battery Monitor String Jar Health event happens." ::= { s450notifications 538 } s450CameraTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock camera trap is issued when a camera event happens." ::= { s450notifications 539 } s450ACTotalPowerFactorTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock AC power monitor total power factor trap is issued when an AC power monitor total power factor event happens." ::= { s450notifications 540 } s450ResetTrap NOTIFICATION-TYPE OBJECTS { siteName, stockTrapString, trapTypeString } STATUS current DESCRIPTION "A stock reset trap is issued when a reset event happens." ::= { s450notifications 543 } s450UserTrap1000 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1000." ::= { s450notifications 1000 } s450UserTrap1001 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1001." ::= { s450notifications 1001 } s450UserTrap1002 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1002." ::= { s450notifications 1002 } s450UserTrap1003 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1003." ::= { s450notifications 1003 } s450UserTrap1004 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1004." ::= { s450notifications 1004 } s450UserTrap1005 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1005." ::= { s450notifications 1005 } s450UserTrap1006 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1006." ::= { s450notifications 1006 } s450UserTrap1007 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1007." ::= { s450notifications 1007 } s450UserTrap1008 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1008." ::= { s450notifications 1008 } s450UserTrap1009 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1009." ::= { s450notifications 1009 } s450UserTrap1010 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1010." ::= { s450notifications 1010 } s450UserTrap1011 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1011." ::= { s450notifications 1011 } s450UserTrap1012 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1012." ::= { s450notifications 1012 } s450UserTrap1013 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1013." ::= { s450notifications 1013 } s450UserTrap1014 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1014." ::= { s450notifications 1014 } s450UserTrap1015 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1015." ::= { s450notifications 1015 } s450UserTrap1016 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1016." ::= { s450notifications 1016 } s450UserTrap1017 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1017." ::= { s450notifications 1017 } s450UserTrap1018 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1018." ::= { s450notifications 1018 } s450UserTrap1019 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1019." ::= { s450notifications 1019 } s450UserTrap1020 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1020." ::= { s450notifications 1020 } s450UserTrap1021 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1021." ::= { s450notifications 1021 } s450UserTrap1022 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1022." ::= { s450notifications 1022 } s450UserTrap1023 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1023." ::= { s450notifications 1023 } s450UserTrap1024 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1024." ::= { s450notifications 1024 } s450UserTrap1025 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1025." ::= { s450notifications 1025 } s450UserTrap1026 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1026." ::= { s450notifications 1026 } s450UserTrap1027 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1027." ::= { s450notifications 1027 } s450UserTrap1028 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1028." ::= { s450notifications 1028 } s450UserTrap1029 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1029." ::= { s450notifications 1029 } s450UserTrap1030 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1030." ::= { s450notifications 1030 } s450UserTrap1031 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1031." ::= { s450notifications 1031 } s450UserTrap1032 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1032." ::= { s450notifications 1032 } s450UserTrap1033 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1033." ::= { s450notifications 1033 } s450UserTrap1034 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1034." ::= { s450notifications 1034 } s450UserTrap1035 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1035." ::= { s450notifications 1035 } s450UserTrap1036 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1036." ::= { s450notifications 1036 } s450UserTrap1037 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1037." ::= { s450notifications 1037 } s450UserTrap1038 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1038." ::= { s450notifications 1038 } s450UserTrap1039 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1039." ::= { s450notifications 1039 } s450UserTrap1040 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1040." ::= { s450notifications 1040 } s450UserTrap1041 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1041." ::= { s450notifications 1041 } s450UserTrap1042 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1042." ::= { s450notifications 1042 } s450UserTrap1043 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1043." ::= { s450notifications 1043 } s450UserTrap1044 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1044." ::= { s450notifications 1044 } s450UserTrap1045 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1045." ::= { s450notifications 1045 } s450UserTrap1046 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1046." ::= { s450notifications 1046 } s450UserTrap1047 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1047." ::= { s450notifications 1047 } s450UserTrap1048 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1048." ::= { s450notifications 1048 } s450UserTrap1049 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1049." ::= { s450notifications 1049 } s450UserTrap1050 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1050." ::= { s450notifications 1050 } s450UserTrap1051 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1051." ::= { s450notifications 1051 } s450UserTrap1052 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1052." ::= { s450notifications 1052 } s450UserTrap1053 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1053." ::= { s450notifications 1053 } s450UserTrap1054 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1054." ::= { s450notifications 1054 } s450UserTrap1055 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1055." ::= { s450notifications 1055 } s450UserTrap1056 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1056." ::= { s450notifications 1056 } s450UserTrap1057 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1057." ::= { s450notifications 1057 } s450UserTrap1058 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1058." ::= { s450notifications 1058 } s450UserTrap1059 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1059." ::= { s450notifications 1059 } s450UserTrap1060 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1060." ::= { s450notifications 1060 } s450UserTrap1061 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1061." ::= { s450notifications 1061 } s450UserTrap1062 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1062." ::= { s450notifications 1062 } s450UserTrap1063 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1063." ::= { s450notifications 1063 } s450UserTrap1064 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1064." ::= { s450notifications 1064 } s450UserTrap1065 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1065." ::= { s450notifications 1065 } s450UserTrap1066 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1066." ::= { s450notifications 1066 } s450UserTrap1067 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1067." ::= { s450notifications 1067 } s450UserTrap1068 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1068." ::= { s450notifications 1068 } s450UserTrap1069 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1069." ::= { s450notifications 1069 } s450UserTrap1070 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1070." ::= { s450notifications 1070 } s450UserTrap1071 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1071." ::= { s450notifications 1071 } s450UserTrap1072 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1072." ::= { s450notifications 1072 } s450UserTrap1073 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1073." ::= { s450notifications 1073 } s450UserTrap1074 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1074." ::= { s450notifications 1074 } s450UserTrap1075 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1075." ::= { s450notifications 1075 } s450UserTrap1076 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1076." ::= { s450notifications 1076 } s450UserTrap1077 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1077." ::= { s450notifications 1077 } s450UserTrap1078 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1078." ::= { s450notifications 1078 } s450UserTrap1079 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1079." ::= { s450notifications 1079 } s450UserTrap1080 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1080." ::= { s450notifications 1080 } s450UserTrap1081 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1081." ::= { s450notifications 1081 } s450UserTrap1082 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1082." ::= { s450notifications 1082 } s450UserTrap1083 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1083." ::= { s450notifications 1083 } s450UserTrap1084 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1084." ::= { s450notifications 1084 } s450UserTrap1085 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1085." ::= { s450notifications 1085 } s450UserTrap1086 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1086." ::= { s450notifications 1086 } s450UserTrap1087 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1087." ::= { s450notifications 1087 } s450UserTrap1088 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1088." ::= { s450notifications 1088 } s450UserTrap1089 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1089." ::= { s450notifications 1089 } s450UserTrap1090 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1090." ::= { s450notifications 1090 } s450UserTrap1091 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1091." ::= { s450notifications 1091 } s450UserTrap1092 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1092." ::= { s450notifications 1092 } s450UserTrap1093 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1093." ::= { s450notifications 1093 } s450UserTrap1094 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1094." ::= { s450notifications 1094 } s450UserTrap1095 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1095." ::= { s450notifications 1095 } s450UserTrap1096 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1096." ::= { s450notifications 1096 } s450UserTrap1097 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1097." ::= { s450notifications 1097 } s450UserTrap1098 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1098." ::= { s450notifications 1098 } s450UserTrap1099 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1099." ::= { s450notifications 1099 } s450UserTrap1100 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1100." ::= { s450notifications 1100 } s450UserTrap1101 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1101." ::= { s450notifications 1101 } s450UserTrap1102 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1102." ::= { s450notifications 1102 } s450UserTrap1103 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1103." ::= { s450notifications 1103 } s450UserTrap1104 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1104." ::= { s450notifications 1104 } s450UserTrap1105 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1105." ::= { s450notifications 1105 } s450UserTrap1106 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1106." ::= { s450notifications 1106 } s450UserTrap1107 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1107." ::= { s450notifications 1107 } s450UserTrap1108 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1108." ::= { s450notifications 1108 } s450UserTrap1109 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1109." ::= { s450notifications 1109 } s450UserTrap1110 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1110." ::= { s450notifications 1110 } s450UserTrap1111 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1111." ::= { s450notifications 1111 } s450UserTrap1112 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1112." ::= { s450notifications 1112 } s450UserTrap1113 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1113." ::= { s450notifications 1113 } s450UserTrap1114 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1114." ::= { s450notifications 1114 } s450UserTrap1115 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1115." ::= { s450notifications 1115 } s450UserTrap1116 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1116." ::= { s450notifications 1116 } s450UserTrap1117 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1117." ::= { s450notifications 1117 } s450UserTrap1118 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1118." ::= { s450notifications 1118 } s450UserTrap1119 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1119." ::= { s450notifications 1119 } s450UserTrap1120 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1120." ::= { s450notifications 1120 } s450UserTrap1121 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1121." ::= { s450notifications 1121 } s450UserTrap1122 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1122." ::= { s450notifications 1122 } s450UserTrap1123 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1123." ::= { s450notifications 1123 } s450UserTrap1124 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1124." ::= { s450notifications 1124 } s450UserTrap1125 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1125." ::= { s450notifications 1125 } s450UserTrap1126 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1126." ::= { s450notifications 1126 } s450UserTrap1127 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1127." ::= { s450notifications 1127 } s450UserTrap1128 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1128." ::= { s450notifications 1128 } s450UserTrap1129 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1129." ::= { s450notifications 1129 } s450UserTrap1130 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1130." ::= { s450notifications 1130 } s450UserTrap1131 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1131." ::= { s450notifications 1131 } s450UserTrap1132 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1132." ::= { s450notifications 1132 } s450UserTrap1133 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1133." ::= { s450notifications 1133 } s450UserTrap1134 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1134." ::= { s450notifications 1134 } s450UserTrap1135 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1135." ::= { s450notifications 1135 } s450UserTrap1136 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1136." ::= { s450notifications 1136 } s450UserTrap1137 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1137." ::= { s450notifications 1137 } s450UserTrap1138 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1138." ::= { s450notifications 1138 } s450UserTrap1139 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1139." ::= { s450notifications 1139 } s450UserTrap1140 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1140." ::= { s450notifications 1140 } s450UserTrap1141 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1141." ::= { s450notifications 1141 } s450UserTrap1142 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1142." ::= { s450notifications 1142 } s450UserTrap1143 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1143." ::= { s450notifications 1143 } s450UserTrap1144 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1144." ::= { s450notifications 1144 } s450UserTrap1145 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1145." ::= { s450notifications 1145 } s450UserTrap1146 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1146." ::= { s450notifications 1146 } s450UserTrap1147 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1147." ::= { s450notifications 1147 } s450UserTrap1148 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1148." ::= { s450notifications 1148 } s450UserTrap1149 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1149." ::= { s450notifications 1149 } s450UserTrap1150 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1150." ::= { s450notifications 1150 } s450UserTrap1151 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1151." ::= { s450notifications 1151 } s450UserTrap1152 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1152." ::= { s450notifications 1152 } s450UserTrap1153 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1153." ::= { s450notifications 1153 } s450UserTrap1154 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1154." ::= { s450notifications 1154 } s450UserTrap1155 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1155." ::= { s450notifications 1155 } s450UserTrap1156 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1156." ::= { s450notifications 1156 } s450UserTrap1157 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1157." ::= { s450notifications 1157 } s450UserTrap1158 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1158." ::= { s450notifications 1158 } s450UserTrap1159 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1159." ::= { s450notifications 1159 } s450UserTrap1160 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1160." ::= { s450notifications 1160 } s450UserTrap1161 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1161." ::= { s450notifications 1161 } s450UserTrap1162 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1162." ::= { s450notifications 1162 } s450UserTrap1163 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1163." ::= { s450notifications 1163 } s450UserTrap1164 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1164." ::= { s450notifications 1164 } s450UserTrap1165 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1165." ::= { s450notifications 1165 } s450UserTrap1166 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1166." ::= { s450notifications 1166 } s450UserTrap1167 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1167." ::= { s450notifications 1167 } s450UserTrap1168 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1168." ::= { s450notifications 1168 } s450UserTrap1169 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1169." ::= { s450notifications 1169 } s450UserTrap1170 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1170." ::= { s450notifications 1170 } s450UserTrap1171 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1171." ::= { s450notifications 1171 } s450UserTrap1172 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1172." ::= { s450notifications 1172 } s450UserTrap1173 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1173." ::= { s450notifications 1173 } s450UserTrap1174 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1174." ::= { s450notifications 1174 } s450UserTrap1175 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1175." ::= { s450notifications 1175 } s450UserTrap1176 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1176." ::= { s450notifications 1176 } s450UserTrap1177 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1177." ::= { s450notifications 1177 } s450UserTrap1178 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1178." ::= { s450notifications 1178 } s450UserTrap1179 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1179." ::= { s450notifications 1179 } s450UserTrap1180 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1180." ::= { s450notifications 1180 } s450UserTrap1181 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1181." ::= { s450notifications 1181 } s450UserTrap1182 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1182." ::= { s450notifications 1182 } s450UserTrap1183 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1183." ::= { s450notifications 1183 } s450UserTrap1184 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1184." ::= { s450notifications 1184 } s450UserTrap1185 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1185." ::= { s450notifications 1185 } s450UserTrap1186 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1186." ::= { s450notifications 1186 } s450UserTrap1187 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1187." ::= { s450notifications 1187 } s450UserTrap1188 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1188." ::= { s450notifications 1188 } s450UserTrap1189 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1189." ::= { s450notifications 1189 } s450UserTrap1190 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1190." ::= { s450notifications 1190 } s450UserTrap1191 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1191." ::= { s450notifications 1191 } s450UserTrap1192 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1192." ::= { s450notifications 1192 } s450UserTrap1193 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1193." ::= { s450notifications 1193 } s450UserTrap1194 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1194." ::= { s450notifications 1194 } s450UserTrap1195 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1195." ::= { s450notifications 1195 } s450UserTrap1196 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1196." ::= { s450notifications 1196 } s450UserTrap1197 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1197." ::= { s450notifications 1197 } s450UserTrap1198 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1198." ::= { s450notifications 1198 } s450UserTrap1199 NOTIFICATION-TYPE OBJECTS { siteName, esIndex, esName, trapEventTypeNumber, trapEventTypeName, esIndexPoint, esPointName, esID, clock, trapIncludedValue, trapIncludedString, trapEventClassNumber, trapEventClassName } STATUS current DESCRIPTION "This user-defined trap is issued when an event happens that causes a trap with specific trap type 1199." ::= { s450notifications 1199 } END