CADANT-CMTS-SYSTEM-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, MODULE-IDENTITY, Counter32, Integer32, IpAddress, Unsigned32 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF TruthValue, DisplayString, MacAddress, DateAndTime, RowStatus FROM SNMPv2-TC InetAddressType, InetAddress, InetAddressIPv4, InetAddressIPv6 FROM INET-ADDRESS-MIB InterfaceIndexOrZero FROM IF-MIB cadSystem FROM CADANT-PRODUCTS-MIB CardId, AdminState, ServerType, OverloadThreshold, AdminSrcAddrType FROM CADANT-TC BitRate FROM DOCS-QOS3-MIB TenthdB FROM DOCS-IF-MIB SnmpAdminString, SnmpEngineID FROM SNMP-FRAMEWORK-MIB; cadSystemMib MODULE-IDENTITY LAST-UPDATED "201511110000Z" -- November 11, 2015 ORGANIZATION "ARRIS Group, Inc." CONTACT-INFO "Arris Technical Support Phone: +1 630 281 3000 E-Mail: support@arris.com" DESCRIPTION "Arris E6000 system parameters and constants" -- REVISION "201512150000Z" -- DESCRIPTION -- "Add operation mode to prevent modems from using an upstream frequency beyond 42 MHz." REVISION "201511110000Z" -- November 11, 2015 DESCRIPTION "Add ofdmSparingCleanupOff(8) to cadSysSpOperMode" REVISION "201511060000Z" -- November 6, 2015 DESCRIPTION "Adjust default network packet/event rates." REVISION "201509100000Z" -- Sept 10, 2015 DESCRIPTION "Add upDownTrapIfDescrOff(7) to cadSysSpOperMode" REVISION "201507210000Z" -- July 21, 2015 DESCRIPTION "Change upper limit of cadSysLicensePorts from 1000 to 5000." REVISION "201506030000Z" -- June 3, 2015 DESCRIPTION "Change upper limit of cadSysLicensePorts from 256 to 1000." REVISION "201503300000Z" -- March 30, 2015 DESCRIPTION "Change default value of cadSysContact from support@arrisi.com to support@arris.com." REVISION "201503050000Z" -- March 5, 2015 DESCRIPTION "Increase the allowed IGMP throttle rate." REVISION "201410070000Z" -- Oct 7, 2014 DESCRIPTION "Add cadSysProcErmRpcPacketRate, cadSysProcErmRpcPacketsReceivedPassed and cadSysProcErmRpcPacketsReceivedDropped." REVISION "201408050000Z" -- Aug 5, 2014 DESCRIPTION "Add cadSysAES128Enable." REVISION "201406100000Z" -- June 10, 2014 DESCRIPTION "Add configuration for flap list insertion." REVISION "201405290000Z" -- May 29, 2014 DESCRIPTION "Remove support for reduced TCS generation (i.e. remove tcsReducedOff(8) from cadSysSpOperMode)." REVISION "201405210000Z" -- May 21, 2014 DESCRIPTION "Changed cadSysMtceDULPacketInterval default from 30000 to 10000" REVISION "201405140000Z" -- May 14, 2014 DESCRIPTION "Remove cadSysModPriUsInTcsEnabled and cadSysModPriUsDbcEnabled" REVISION "201404250000Z" -- April 25, 2014 DESCRIPTION "Change default value of cadSysProcVrepPacketRate and cadSysProcVpmePacketRate" REVISION "201404100000Z" -- April 10, 2014 DESCRIPTION "Add cadSysProcVrepPacketRate, cadSysProcVpmePacketRate, cadSysProcVrepPacketsReceivedPassed, cadSysProcVrepPacketsReceivedDropped, cadSysProcVpmePacketsReceivedPassed and cadSysProcVpmePacketsReceivedDropped." REVISION "201403130000Z" -- March 13, 2014 DESCRIPTION "Add cadSysProcLacpPacketRate, cadSysProcLacpPacketsReceivedPassed and cadSysProcLacpPacketsReceivedDropped." REVISION "201403060000Z" -- March 6, 2014 DESCRIPTION "Add cadSysPatchParams." REVISION "201402210000Z" -- Feburary 21, 2014 DESCRIPTION "Add cadSysModPriUsInTcsEnabled and cadSysModPriUsDbcEnabled" REVISION "201401160000Z" -- January 16, 2014 DESCRIPTION "remove rcsLoadBalOn(20) from cadSysSpOperMode." REVISION "201311190000Z" -- November 19, 2013 DESCRIPTION "Add operation mode for RCS load balancing control." REVISION "201309060000Z" -- Sep 6, 2013 DESCRIPTION "Add cadSysProcClearPolicingCounts." REVISION "201308130000Z" -- August 13, 2013 DESCRIPTION "Add support for LDP protocol throttling." REVISION "201307220000Z" -- July 22, 2013 DESCRIPTION "Add an additional reload status value for patch apply" REVISION "201307100000Z" -- July 10, 2013 DESCRIPTION "Removed factoryDCAMTestOff(7) from cadSysSpOperMode" REVISION "201307010000Z" -- July 1, 2013 DESCRIPTION "Add patch apply support." REVISION "201306210000Z" -- June 21, 2013 DESCRIPTION "Add support for reduced TCS generation." REVISION "201306200000Z" -- June 20, 2013 DESCRIPTION "Add cadSys1x1onCmAcPwrLossEnabled." REVISION "201306190000Z" -- Jun 19, 2013 DESCRIPTION "Add NPU Host Event throttling rate into CadSysProcPolicingConfig and related counts into CadSysProcPolicingCounts." REVISION "201305150000Z" -- May 5, 2013 DESCRIPTION "Add cadSysMICSecondarySecretTable." REVISION "201301080000Z" -- January 8, 2013 DESCRIPTION "Add patching operation support." REVISION "201212030000Z" -- Dec 3, 2012 DESCRIPTION "Remove fiveTapPtsOff(20) from cadSysSpOperMode." REVISION "201211300000Z" -- Nov 30, 2012 DESCRIPTION "Rename object names in cadLaesMdTimestampModeTable" REVISION "201211150000Z" -- Oct 15, 2012 DESCRIPTION "Add loadBalUnbondedVoipOn(6) and factoryDCAMTestOff(7) to cadSysSpOperMode" REVISION "201210040000Z" -- Oct 4, 2012 DESCRIPTION "Remove cadSysDownChannelAnnex" REVISION "201210010000Z" -- Oct 1, 2012 DESCRIPTION "Add cadLaesMdTimestampModeTable" REVISION "201206150000Z" -- June 15, 2012 DESCRIPTION "remove CadSysSourceInterface table and remove cadSnmpSourceIpAddrType and cadSnmpSourceIpAddr" REVISION "201203220000Z" -- Mar 22, 2012 DESCRIPTION "Add port licensing control." REVISION "201203040000Z" -- Mar 4, 2012 DESCRIPTION "Add new reload status values for standby firmware upgrade and standby write mem." REVISION "201202230000Z" -- Feb 23, 2012 DESCRIPTION "Add cadSysSourceAddressTable" REVISION "201202080000Z" -- February 9, 2012 DESCRIPTION "Add support for enhanced SNR with new TAPs." REVISION "201201180000Z" -- Jan 18, 2012 DESCRIPTION "Add new reload status value for image copy." REVISION "201112130000Z" -- Dec 13, 2011 DESCRIPTION "Add new reload status value." REVISION "201111170000Z" -- Nov 17, 2011 DESCRIPTION "Add new reload status values." REVISION "201111080000Z" -- Nov 8, 2011 DESCRIPTION "Removed upstreamLockupIgnore and upstreamLockupDetectLong. Add support for maintenance lockup detection configuration." REVISION "201111040000Z" -- Nov 4, 2011 DESCRIPTION "Remove the following MIB objects: cadSysProcScmGlobalPacketRate ,cadSysProcScmGlobalPacketsReceivedPassed, cadSysProcScmGlobalPacketsReceivedDropped,cadSysProcOspfv3PacketsSent, cadSysProcTftpIpv6PacketsSent,cadSysProcRouterControlGlobalPacketsSent, cadSysProcArpPacketsSent, cadSysProcDhcpPacketsSent, cadSysProcIcmpPacketsSent, cadSysProcOspfPacketsSent, cadSysProcRipPacketsSent, cadSysProcIgmpPacketsSent, cadSysProcRouterControlOtherPacketsSent, cadSysProcSnmpPacketsSent, cadSysProcTftpPacketsSent, cadSysProcIsisPacketsSent, cadSysProcScmGlobalPacketsSent, cadSysProcNdPacketsSent, cadSysProcDhcpIpv6PacketsSent, cadSysProcIcmpIpv6PacketsSent, cadSysProcMldPacketsSent, cadSysProcBgpPacketsSent, cadSysProcPimPacketsSent, cadSysProcSnmpCmPacketsSent, cadSysProcCopsPacketsSent, and cadSysProcTelnetPacketsSent." REVISION "201107080000Z" -- July 8, 2011 DESCRIPTION "Add support for maintenance control of fan speed." REVISION "201105220000Z" -- May 22, 2011 DESCRIPTION "Add support for maintenance overload configuration." REVISION "201104050000Z" -- Apr 5, 2011 DESCRIPTION "Modified allowed values of cadSysReloadStatus." REVISION "201103030000Z" -- March 3, 2011 DESCRIPTION "Add cadSysTftpProxy cadSysProcTftpIpv6PacketRate cadSysProcTftpIpv6PacketsReceivedPassed cadSysProcTftpIpv6PacketsReceivedDropped cadSysProcTftpIpv6PacketsSent" REVISION "201102230000Z" -- Feb 23, 2011 DESCRIPTION "Add cpeNacksForceCmReset bit back to cadSysSpOperMode" REVISION "201012220000Z" -- Dec 22, 2010 DESCRIPTION "Change cadSysDataServerSnmpRefreshTime to be in seconds" REVISION "201012100000Z" -- Dec 10, 2010 DESCRIPTION "Deprecated upstreamLockupIgnore and upstreamLockupDetectLong and cadSysModemLossThreshold" REVISION "201012010000Z" -- Dec 1, 2010 DESCRIPTION "Add cadSysSnmpReadAheadMax and cadSysSnmpRefreshTime" REVISION "201011180000Z" -- Nov 18, 2010 DESCRIPTION "Add cadSysMacMoveBlockedOnRcptDhcpPkt" REVISION "201009220000Z" -- Sep 22, 2010 DESCRIPTION "Add support for DataServer variables." REVISION "201009150000Z" -- Sep 15, 2010 DESCRIPTION "Add pending(3), and none(4) to cadSysXDLicKeyStatus" REVISION "201009020000Z" -- Sep 2, 2010 DESCRIPTION "Add cadSysUnicastNpUsAcquisition" REVISION "201007310000Z" -- July 31, 2010 DESCRIPTION "Add support for OSPFv3 counts." REVISION "201007210000Z" -- July 21, 2010 DESCRIPTION "Remove cadSysAttrFlowAssignStrictEnforcement" REVISION "201007120000Z" -- July 12, 2010 DESCRIPTION "Add cadSysAttrFlowAssignStrictEnforcement" REVISION "201003150000Z" -- Mar 15, 2010 DESCRIPTION "Add cadSysAllowAmbiguityOverride" REVISION "201002230000Z" -- Feb 23, 2010 DESCRIPTION "Deprecate cadSysControlGroup" REVISION "201002110000Z" -- Feb 11, 2010 DESCRIPTION "Add reloadWritemem and reloadEraseMem to cadSysReloadOperation and eraseMem and remoteEraseMem to cadSysReloadStatus" REVISION "201001080000Z" -- Jan 8, 2010 DESCRIPTION "Add cadSysPeakTrRateUpstream and cadCosUpPeakTrafficRate for Upstream Power Boot feature. Make cadSysPeakTrafRateFor11CMs obsolete" REVISION "200910080000Z" -- Oct 8, 2009 DESCRIPTION "change default value of cadSysDelayedCpeLearning from false(2) to true(1)" REVISION "200909220000Z" -- Sep 22, 2009 DESCRIPTION "chagne default value of cadSysProcNdPacketRate from 1000 to 700" REVISION "200909140000Z" -- Sep 14, 2009 DESCRIPTION "Add cadSysSendTccRefIdPerFragment" REVISION "200908170000Z" -- Aug 17, 2009 DESCRIPTION "Add cadSysModPriDsInRccEnabled" REVISION "200905040000Z" -- May 4, 2009 DESCRIPTION "Add new cadSysSpOperMode use16ForDSPeakTrafficRate" REVISION "200904220000Z" -- Apr 22, 2009 DESCRIPTION "Added cadSysSourceIpAddrCableIntercept, cadSysSourceInterfaceCableIntercept and cadSnmpSourceIpAddrTypeCableIntercept." REVISION "200901230000Z" -- Jan 23, 2009 DESCRIPTION "Added cadSysDelayedCpeLearning." REVISION "200812180000Z" -- December 18, 2008 DESCRIPTION "cadSysProcArpPacketRate default value changed from 2500 to 700" REVISION "200812080000Z" -- December 8, 2008 DESCRIPTION "Add cadMtcmConditionalOverride." REVISION "200810220000Z" -- October 22, 2008 DESCRIPTION "Add cadSysLO1LeakDetect control for DMM LO1 spurs." REVISION "200809240000Z" -- Sep 24, 2008 DESCRIPTION "Add cadSysProcCopsPacketRate and cadSysProcTelnetPacketRate." REVISION "200809150000Z" -- Sep 15, 2008 DESCRIPTION "Change default value of cadSysProcSnmpPacketRate from 100 to 650." REVISION "200808280000Z" -- Aug 28, 2008 DESCRIPTION "Add cadSysMaxUcdBurstLength." REVISION "200803170000Z" -- March 17, 2008 DESCRIPTION "Add oper mode bit for policy TLV and protocol throttling for IPV6." REVISION "200802190000Z" -- Feb 19, 2008 DESCRIPTION "Modified allowed values of cadSysReloadStatus." REVISION "200802040000Z" -- Feb 4, 2008 DESCRIPTION "Added cadSysDownChannelAnnex. Annex is configured per CMTS bassis." REVISION "200712020000Z" -- December 2, 2007 DESCRIPTION "Added additional reload support" REVISION "200611090000Z" -- November 9, 2006 DESCRIPTION "Add oneDCmDSMaxTrafBurstOn to operation mode." REVISION "200608290000Z" -- August 29, 2006 DESCRIPTION "Add cadSysSourceInterfaceRemoteQuery to cadSysSourceInterface Object." REVISION "200608100000Z" -- August 10, 2006 DESCRIPTION "Add bpiHybridOff to cadSysSpOperMode object." REVISION "200607120000Z" DESCRIPTION "Added SNMP remote engine support." REVISION "200602220000Z" DESCRIPTION "Removed cpeNacksForceCmReset bit from cadSysSpOperMode" REVISION "200601250000Z" DESCRIPTION "Added upstreamLockupDetectLong BIT to cadSysSpOperMode for longer upstream lockup detect sampling period." REVISION "200601120000Z" DESCRIPTION "Added cadSysMtceParams for maintenance intervals and scheduling." REVISION "200601030000Z" DESCRIPTION "Added cadSysCpeHostAuthorization for CPE Host Authorization (Motorola Style Anti-Spoofing) feature." REVISION "200509230000Z" DESCRIPTION "Added cadSnmpSourceIp for Legal Intercept feature." REVISION "200509210000Z" DESCRIPTION "Add support for suppressing downstream priority channel mapping add support for virtual modems." REVISION "200508300000Z" DESCRIPTION "Add support for disabling downstream override and supressing DCDs." REVISION "200508240000Z" DESCRIPTION "Added cadSysPeakTrafRateFor11CMs." REVISION "200508080000Z" DESCRIPTION "Add support for DOCSIS 1.0+" REVISION "200507110000Z" DESCRIPTION "Added cadCosDnPeakTrafficRate for Traffic Shaping for 2D12U feature." REVISION "200506200000Z" DESCRIPTION "Renamed showCmFormatCV bit to showCmFormatCVOff and flipped the semantics" REVISION "200506080000Z" DESCRIPTION "Added SCM Global counts" REVISION "200505180000Z" DESCRIPTION "Added bpiDynamicMulticastOff bit to cadSysSpOperMode" REVISION "200504210000Z" DESCRIPTION "Added showCmFormatCV bit to cadSysSpOperMode" REVISION "200504140000Z" DESCRIPTION "Merge with 4.6" REVISION "200503010000Z" DESCRIPTION "Remove obsolete error recovery bits" REVISION "200501060000Z" DESCRIPTION "Included support for Source Interface for SNMP Traps." REVISION "200412030000Z" DESCRIPTION "Included support for TFTP Enforce feature." REVISION "200410120000Z" DESCRIPTION "Included support for SNMP policing on the FCM." REVISION "200409220000Z" DESCRIPTION "Included cadSysTcpSmoothingValue1D8U and cadSysTcpSmoothingValue2D12U in the cadSysParamsGroup." REVISION "200404300000Z" DESCRIPTION "Added IS-IS counts." REVISION "200404130000Z" DESCRIPTION "Included cadSysRemoteFSEnable and cadSysRemotePortEnable in the cadSysParamsGroup." REVISION "200403230000Z" DESCRIPTION "Added cadSysRemoteFSEnable and cadSysRemotePortEnable for allowing the active SCM to access filesystems and ports of the standby SCM." REVISION "200402230000Z" DESCRIPTION "Added cadSysFlaplistPowerAdjustThreshold for FlapManager enhancement." REVISION "200402200000Z" DESCRIPTION "Add automatic fan control switch to sysparams." REVISION "200312050000Z" DESCRIPTION "Change default FCM other protocol policing rate for BGP." REVISION "200310280000Z" DESCRIPTION "Removed mapgbdiff, mapgbsm1, mapgbsm2, ptcspec, and preeq10 from cadSysSpOperMode object." REVISION "200310210000Z" DESCRIPTION "Changed cadCosToQosMapping scalar object to a table." REVISION "200310200000Z" DESCRIPTION "Changed bootparams to rw." REVISION "200308260000Z" DESCRIPTION "Added default maximum traffic burst for 1.1 CMs." REVISION "200308250000Z" DESCRIPTION "Added percent additional downstream bandwidth allocated for dynamic service flows." REVISION "200308180000Z" DESCRIPTION "Change default FCM policing default rates" REVISION "200308060000Z" DESCRIPTION "Added upce bit to cadSysSpOperMode" REVISION "200306160000Z" DESCRIPTION "Added cpeNacksForceCmReset bit to cadSysSpOperMode" REVISION "200305230000Z" DESCRIPTION "Changed default of cadSysMaxQoSActiveTimeout from 0 to 30" REVISION "200305080000Z" DESCRIPTION "Add server enable/disable support." REVISION "200304300000Z" DESCRIPTION "Add both front panel addresses to bootparams." REVISION "200304200000Z" DESCRIPTION "Changed maximum size of MIC authstring to 64 bytes." REVISION "200304140000Z" DESCRIPTION "Added cmstatusoperational bit to cadSysSpOperMode object." REVISION "200303200000Z" DESCRIPTION "Added ability to provision whether a CM in 1.0 can use concat and/or frag" REVISION "200303140000Z" DESCRIPTION "Added maximum allowed QoS Active and Admitted Timeout values" REVISION "200303070000Z" DESCRIPTION "Change length of MIC auth string" REVISION "200302140000Z" DESCRIPTION "Added tables to support banner related objects. Change encoding of MIC auth string" REVISION "200212120000Z" DESCRIPTION "Removed special operating mode for preeq." REVISION "200211220000Z" DESCRIPTION "Added control object for erasing NVRAM." REVISION "200211200000Z" DESCRIPTION "Add processor protocol policing objects." REVISION "200210040000Z" DESCRIPTION "Added special operating mode for preeq." REVISION "200210030000Z" DESCRIPTION "Changed cadCosUpMaxTrafficBurst from 1522 to 3044, per RFI-N-02091." REVISION "200207020000Z" DESCRIPTION "Changed cadSysCMConfiguration to read-write." REVISION "200204250000Z" DESCRIPTION "Add key chain objects." REVISION "200204230000Z" DESCRIPTION "Add enbudptcpfltr bit to cadSysSpOperMode object." REVISION "200204220000Z" DESCRIPTION "Add global counts collection rate object." REVISION "200204020001Z" DESCRIPTION "Add cadSysSpOperMode object." REVISION "200204020000Z" DESCRIPTION "Add cosToQosMapping group." REVISION "200201150000Z" DESCRIPTION "Add configuration save time." REVISION "200111070000Z" DESCRIPTION "Add floating IP address and remove NAM support." REVISION "200108180000Z" DESCRIPTION "Add system table dictionary." REVISION "200107180000Z" DESCRIPTION "Add enable/disable for Mcard ports." ::= { cadSystem 1 } --=========== System Objects ============================== cadSysParams OBJECT IDENTIFIER ::= { cadSystemMib 1 } cadSysSystem OBJECT IDENTIFIER ::= { cadSystemMib 2 } cadSysControl OBJECT IDENTIFIER ::= { cadSystemMib 3 } cadSysSnmp OBJECT IDENTIFIER ::= { cadSystemMib 4 } cadSysBootParams OBJECT IDENTIFIER ::= { cadSystemMib 5 } cadSysReload OBJECT IDENTIFIER ::= { cadSystemMib 6 } cadSysImage OBJECT IDENTIFIER ::= { cadSystemMib 7 } cadSysDictionary OBJECT IDENTIFIER ::= { cadSystemMib 8 } cadSysConfiguration OBJECT IDENTIFIER ::= { cadSystemMib 9 } cadCosToQosMapping OBJECT IDENTIFIER ::= { cadSystemMib 10 } cadSysKeyChain OBJECT IDENTIFIER ::= { cadSystemMib 11 } cadSysProcPolicingConfig OBJECT IDENTIFIER ::= { cadSystemMib 13 } cadSysProcPolicingCounts OBJECT IDENTIFIER ::= { cadSystemMib 14 } cadSysBanner OBJECT IDENTIFIER ::= { cadSystemMib 15 } cadSysServer OBJECT IDENTIFIER ::= { cadSystemMib 16 } cadSysPatchParams OBJECT IDENTIFIER ::= { cadSystemMib 17 } cadSysMtceParams OBJECT IDENTIFIER ::= { cadSystemMib 19 } cadSysDataServer OBJECT IDENTIFIER ::= { cadSystemMib 21 } cadSysSourceAddress OBJECT IDENTIFIER ::= { cadSystemMib 22 } cadSysLicenseControl OBJECT IDENTIFIER ::= { cadSystemMib 23 } cadLaesMdTimestampMode OBJECT IDENTIFIER ::= { cadSystemMib 24 } cadSysSharedSecret OBJECT IDENTIFIER ::= { cadSystemMib 25 } --=========== Params Objects ============================== cadSysSyncInterval OBJECT-TYPE SYNTAX Integer32 (0..200) UNITS "Milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Nominal time between transmission of SYNC messages. (ref 6.3.2)" ::= { cadSysParams 1 } cadSysUCDInterval OBJECT-TYPE SYNTAX Integer32 (0..2000) UNITS "Milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Time between transmission of UCD messages. (ref 6.3.3)" ::= { cadSysParams 2 } cadSysMaxMAPPending OBJECT-TYPE SYNTAX Integer32 (0..4096) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of mini-slots that a CMTS is allowed to map into the future. (ref 6.3.4)" ::= { cadSysParams 3 } cadSysRangingInterval OBJECT-TYPE SYNTAX Integer32 (0..2000) UNITS "Milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Time between transmission of broadcast Ranging requests. (ref 7.3.3)" ::= { cadSysParams 4 } cadSysInvitedRangingRetries OBJECT-TYPE SYNTAX Integer32 (16) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of retries on inviting ranging requests. (ref 9.2.4)" ::= { cadSysParams 5 } cadSysRegistrationRequestRetries OBJECT-TYPE SYNTAX Integer32 (3) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of retries on registration requests/responses." ::= { cadSysParams 6 } cadSysCMMAPProcessingTime OBJECT-TYPE SYNTAX Integer32 (200..2000) UNITS "Microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Time provided between arrival of the last bit of a MAP at a CM and effectiveness of that MAP. (ref 7.1.1)" ::= { cadSysParams 7 } cadSysCMRangingResponseProcessingTime OBJECT-TYPE SYNTAX Integer32 (1..200) UNITS "Milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum tile allowed fro a CM following receipt of a rangin response before it is expected to reply to an invited ranging request." ::= { cadSysParams 8 } cadSysCMConfiguration OBJECT-TYPE SYNTAX Integer32 (30..2000) UNITS "Seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum time allowed for a CM, following receipt of a configuration file, to send a Registration Request to a CMTS." DEFVAL { 30 } ::= { cadSysParams 9 } cadSysT5Timeout OBJECT-TYPE SYNTAX Integer32 (0..2000) UNITS "Milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Wait for Upstream CHannel Change response." ::= { cadSysParams 10 } cadSysT6Timeout OBJECT-TYPE SYNTAX Integer32 (0..3000) UNITS "Milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Wait for REG-RSP and REG-ACK" ::= { cadSysParams 11 } cadSysMiniSlotSize OBJECT-TYPE SYNTAX Integer32 (32..300) MAX-ACCESS read-only STATUS current DESCRIPTION "Size of mini-slotfor upstream transmission. Must be a power of 2 (in units of the Timebase Tick)." ::= { cadSysParams 12 } cadSysDSxRequestRetries OBJECT-TYPE SYNTAX Integer32 (3) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Timeout Retries on DSA/DSC/DSD Requests." ::= { cadSysParams 13 } cadSysDSxResponseRetries OBJECT-TYPE SYNTAX Integer32 (3) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Timeout Retries on DSA/DSC/DSD Responses." ::= { cadSysParams 14 } cadSysT7Timeout OBJECT-TYPE SYNTAX Integer32 (0..1000) UNITS "Milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Wait for DSA/DSC/DSD Response timeout." ::= { cadSysParams 15 } cadSysT8Timeout OBJECT-TYPE SYNTAX Integer32 (0..300) UNITS "Milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Wait for DSA/DSC/DSD Acknowledge timeout." ::= { cadSysParams 16 } cadSysT9Timeout OBJECT-TYPE SYNTAX Integer32 (15..1500) UNITS "Minutes" MAX-ACCESS read-only STATUS current DESCRIPTION "Registration timeout, the time allowed between the CMTS sending a RNG-RSP(success) to a CM, and receiving a REG-REQ from that same CM." ::= { cadSysParams 17 } cadSysT10Timeout OBJECT-TYPE SYNTAX Integer32 (0..3000) UNITS "Milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Wait for Transaction End timeout." ::= { cadSysParams 18 } cadSysT11Timeout OBJECT-TYPE SYNTAX Integer32 (0..300) UNITS "Milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Wait for a DCC Response on the old channel." ::= { cadSysParams 19 } cadSysT13Timeout OBJECT-TYPE SYNTAX Integer32 (0..1000) UNITS "Milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum holding time for QOS resources for DCC." ::= { cadSysParams 20 } cadSysDCCREQRetries OBJECT-TYPE SYNTAX Integer32 (3) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of retries on Dynamic Channel Change Request." ::= { cadSysParams 21 } cadSysMICEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable MIC checking on the CMTS." ::= { cadSysParams 22 } cadSysMICAuthString OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Encrypted MIC Authentication" ::= { cadSysParams 23 } cadSysAutoRecoveryEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable automatic recovery of card/port/software in case of component failure." DEFVAL { true } ::= { cadSysParams 24 } cadSysActiveIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Ip Address of the active control complex." DEFVAL { '00000000'h } ::= { cadSysParams 25 } cadSysSpOperMode OBJECT-TYPE SYNTAX BITS { dqossf10cms(0), adjrxpwrctl(1), enbudptcpfltr(2), upce(3), use16ForDSPeakTrafficRate(4), cpeNacksForceCmReset(5), loadBalUnbondedVoipOn(6), upDownTrapIfDescrOff(7), ofdmSparingCleanupOff(8), limitUsRngRspFreqOff(9), reserved10(10), cmstatusoperational(11), reserved12(12), docsis20test(13), reserved14(14), reserved15(15), reserved16(16), reserved17(17), reserved18(18), reserved19(19), reserved20(20), showCmFormatCVOff(21), bpiDynamicMulticastOff(22), docsis10plusOff(23), downstreamOverrideOn(24), supressDCDOff(25), virtualCmOff(26), bpiHybridOff(27), oneDCmDSMaxTrafBurstOn(28), docsis30ReqTxPolicyChkOff(29), reserved30(30), reserved31(31) } MAX-ACCESS read-write STATUS current DESCRIPTION "Special operational mode. Value of 1 indicates the mode is enabled. dqossf10cms - Allow 1.0 CMs to be stored in DocsQosServiceFlowEntry adjrxpwrctl - Allow rx power control to be adjusted by mod type usage enbudptcpfltr - Allow combining of Udp and Tcp messages in a single filter upce - Allow Upstream Packet Classifier Enforcement use16ForDSPeakTrafficRate - use the defunct TLV type 16 for DS peak traffic rate cpeNacksForceCmReset - - Force CM reset upon receiving 3 consecutive CPE NACKs loadBalUnbondedVoipOn - Allow load balancing for non-bonded voice calls limitUsRngRspFreqOff - Prevent CM from using an upstream frequency beyond 42 MHz upDownTrapIfDescrOff - Allow linkup or linkdown trap to include ifDescr ofdmSparingCleanupOff - Allow automatically reset any D3.1 CMs in a cable-mac that has an OFDM channel on that DCAM in the CM's RCS after a failover or fallback cmstatusoperational - Support DOCS-IF-MIB draft-05 (cw26)'s change to docsIfCmtsCmStatusValue, such that online modems take on a value of operational(8) at the CMTS. If disabled, operational(8) is not used and online modems take on a value of registrationComplete(6) at the CMTS. docsis20test - Allow running of DOCSIS 2.0 Tests. showCmFormatCVOff - show cable modem is formatted per CableVision's requirements if set to 0. docsis10plusOff - DOCSIS 1.0+ support is enabled if set to 0. downstreamOverrideOn - downstream overrides are disabled if this is set to 0. supressDCDOff - DCDs are suppressed if set to 0. virtualCmOff - support for virtual modems is enabled if set to 0. bpiHybridOff - Allow DOCSIS 1.1 modems to operate in BPI instead of BPI+ if this is set to 0. oneDCmDSMaxTrafBurstOn - Override Max Traffic Burst for DOCSIS 1.1 modems on a 1D CAM with E6000 setting if this is set to 0. docsis30ReqTxPolicyChkOff - Override DOCSIS 3.0 checking for Request/Transmission Policy TLV on upstream flows. " DEFVAL { { dqossf10cms, adjrxpwrctl, enbudptcpfltr, use16ForDSPeakTrafficRate, cpeNacksForceCmReset, loadBalUnbondedVoipOn, upDownTrapIfDescrOff, ofdmSparingCleanupOff, limitUsRngRspFreqOff, reserved10, cmstatusoperational, reserved12, reserved14, reserved15, reserved16, reserved17, reserved18, reserved19, reserved20, showCmFormatCVOff, bpiDynamicMulticastOff, docsis10plusOff, downstreamOverrideOn, supressDCDOff, virtualCmOff, bpiHybridOff, oneDCmDSMaxTrafBurstOn, docsis30ReqTxPolicyChkOff, reserved30, reserved31 } } -- upce and docsis20test disabled and use16ForDSPeakTrafficRate by default ::= { cadSysParams 26 } cadSysCountsCollectionRate OBJECT-TYPE SYNTAX Unsigned32 (0|15..1440) -- disabled or from 15 minutes to 24 hours MAX-ACCESS read-write STATUS current DESCRIPTION "The period, in minutes, in which every count in the CMTS is to be collected. If this object is set to 0, counts collection will be disabled." DEFVAL { 120 } -- 2 hours ::= { cadSysParams 27 } cadSysMaxQoSActiveTimeout OBJECT-TYPE SYNTAX Integer32 (0..65535) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the maximum QoS Active Timeout the E6000 is willing to allow. If a larger value is received in a CM request the E6000 will return this value instead in the response (Reference DOCSIS RFI Section c.2.2.5.6). Note a value of 0 is infinite and is therefore treated as the largest value in the range." DEFVAL { 30 } ::= { cadSysParams 28 } cadSysMaxQoSAdmittedTimeout OBJECT-TYPE SYNTAX Integer32 (0..65535) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the maximum QoS Admitted Timeout the E6000 is willing to allow. If a larger value is received in a CM request the E6000 will return this value instead in the response (Reference DOCSIS RFI Section c.2.2.5.7). Note a value of 0 is infinite and is therefore treated as the largest value in the range." DEFVAL { 200 } ::= { cadSysParams 29 } cadSysAllow10CmConcatenation OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Defines whether or not the E6000 will allow a modem operating in DOCSIS 1.0 mode to utilize concatenation. If this value is false and a modem operating in 1.0 mode sends up a modem capability indicating concatenation the E6000 will respond by turning that capability off. If this value is true the modem will be returned whatever it requests (on or off)." DEFVAL { false } ::= { cadSysParams 30 } cadSysAllow10CmFragmentation OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Defines whether or not the E6000 will allow a modem operating in DOCSIS 1.0 mode to utilize fragmentation. If this value is false and a modem operating in 1.0 mode sends up a modem capability indicating fragmentation the E6000 will respond by turning that capability off. If this value is true the modem will be returned whatever it requests (on or off)." DEFVAL { true } ::= { cadSysParams 31 } cadSysPercentAddtlDsBwAllocated OBJECT-TYPE SYNTAX Integer32 (0..5) MAX-ACCESS read-write STATUS current DESCRIPTION "This value of this setting is used to make a percentage increase to a dynamic downstream service flows maximum traffic rate. This is flexiblity actually causes the E6000 to operate outside the DOCSIS 1.1 specification by allocating and allowing more traffic than was actually requested. The initial reason for providing this capability is to mask problems produced in the Voice environment where devices have been seen to violate the traffic rates. Examples of this are MTAs that overuse the QI bit for long durations thus overdriving the downstream burst interval and the Neura IPDT gateway introducing an additional 0.5% inband signaling to the DS voice flow" DEFVAL { 1 } ::= { cadSysParams 32 } cadSysMaxTrafBurstFor11CMs OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the default value that will be used to populate the Maximum Traffic Burst for a 1.1 modem unless the maximum traffic burst TLV is explicitly provided in either the modems Request or in a Service Class Name definition. This value is being made programmable for 2 reasons: 1) So that it can be set to the DOCSIS default of 3044 for CableLabs testing and 2) it can be tuned for real world applications." DEFVAL { 128000 } ::= { cadSysParams 33 } cadSysFanSpeedControlEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Enable automatic fan speed control. " DEFVAL { false } ::= { cadSysParams 34 } cadSysFlaplistPowerAdjustThreshold OBJECT-TYPE SYNTAX TenthdB (0|10..100) UNITS "dB" MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold is used to monitor the power adjust in the flap list. For a range request received that results in a power adjust exceeding the threshold value will cause the counter cadIfCmtsCmCountsPowerAdjExceedsThreshold to be incremented. If the threshold is set to 0, the monitoring of power adjustment in the flap list is disabled." DEFVAL { 30 } ::= { cadSysParams 35 } cadSysRemoteFSEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the active SCM should allow mounting the the filesystems of the standby SCM." DEFVAL { true } ::= { cadSysParams 36 } cadSysRemotePortEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the active SCM should allow redirection of the serial console of the standby SCM." DEFVAL { true } ::= { cadSysParams 37 } cadSysTcpSmoothingValue1D8U OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "TCP smoothing value to be programmed into hardware on 1D8U CAMs." DEFVAL { 0 } ::= { cadSysParams 38 } cadSysTcpSmoothingValue2D12U OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "TCP smoothing value to be programmed into hardware on 2D12U CAMs." DEFVAL { 0 } ::= { cadSysParams 39 } cadSysModemLossThreshold OBJECT-TYPE SYNTAX Unsigned32 (10..2000) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Minimum modem threshold triggering detection of an upstream channel lockup." DEFVAL { 10 } ::= { cadSysParams 40 } cadSysPeakTrafRateFor11CMs OBJECT-TYPE SYNTAX BitRate MAX-ACCESS read-write STATUS obsolete DESCRIPTION "This is the default value that will be used to populate the Peak Traffic Rate for a 1.1 modem configuration file unless the peak traffic rate is explicitly provided by a Service Class Name definition." DEFVAL { 0 } ::= { cadSysParams 41 } cadSysCpeHostAuthorization OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This variable enables the CPE Host Authorization feature." DEFVAL { false } ::= { cadSysParams 44 } cadSysMaxUcdBurstLength OBJECT-TYPE SYNTAX Integer32(2048..16128) UNITS "bytes" MAX-ACCESS read-write STATUS current DESCRIPTION "This variable limits the maximum UCD burst length." DEFVAL { 16128 } ::= { cadSysParams 46 } cadSysLO1LeakDetect OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This variable controls LO1 leak detection on the DMM." DEFVAL { false } ::= { cadSysParams 47 } cadMtcmConditionalOverride OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "If set to 'true', for a MAC Domain configured for MTCM enabled operation, the E6000 will set a registering MTCM-capable CM to be MTCM disabled (via REG-RSP message) unless at least one of the config file's service flows was specifically configured to have the Bonded bit set in the Required attribute mask (in which case the CM will be set to MTCM enabled). If set to false, standard DOCSIS 3.0 operation will result." DEFVAL { false } ::= { cadSysParams 48 } cadSysDelayedCpeLearning OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This setting only applies to modems that have BPI enabled. When set to false(2), CPE learning is enabled during registration when BPI initialization is initiated for those modems using BPI. When set to true(1), CPE learning is delayed during registration until BPI initialization is complete for those modems using BPI. For modems not using BPI, CPE learning is enabled when registration is complete." DEFVAL { true } ::= { cadSysParams 49 } cadSysModPriDsInRccEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable modifying primary Downstream channel in RCC of Reg-Rsp-MP. Refer ECN 690." DEFVAL { false } ::= { cadSysParams 52 } cadSysSendTccRefIdPerFragment OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Settings for sending the Transmit Channel Configuration (TCC) Reference sub-type 46.1 for type 46 TCC fragmentation. If 'true', sends 46.1 Ref ID in every type 46 TCC fragment; If 'false', only sends 46.1 Ref ID in the first TCC fragment (DOCSIS Compliant)." DEFVAL { true } ::= { cadSysParams 53 } cadSysPeakTrRateUpstream OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables support for Peak Traffic Rate in the upstream direction." DEFVAL { false } ::= { cadSysParams 54 } cadSysAllowAmbiguityOverride OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables ambiguity resolution channel-override actions." DEFVAL { false } ::= { cadSysParams 55 } cadSysUnicastNpUsAcquisition OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables unicast non-primary upstream channel acquisition." DEFVAL { false } ::= { cadSysParams 56} cadSysMacMoveBlockedOnRcptDhcpPkt OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "MAC movement is blocked on receipt of DHCP packets" DEFVAL { true } ::= { cadSysParams 57 } cadSysTftpProxy OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1), ipv4only(2), ipv6only(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter provides a global enable for the TFTP Enforce and Dynamic Shared Secret features. In order for the cadIfMacDomainTftpEnforce and cadIfMacDomainDynamicSecret parameters to take effect, this parameter must also be enabled. This parameter can also limit those features to only IPv4 transfers or IPv6 transfers." DEFVAL { enable } ::= { cadSysParams 58 } cadSysFanSpeedLevel OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Set the fan speed for the chassis." DEFVAL { 0 } ::= { cadSysParams 59 } cadSys1x1onCmAcPwrLossEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables/disables the CMTS reaction to a AC Power Loss CM-STATUS. If true, the CMTS will wait until cadSys1x1onCmAcPwrLossHoldoff expires, and then the CMTS will place the CM into a 1x1 (US/DS) channel mode to conserve CM battery power. If false, the CMTS will not place a CM that reports an AC Power Loss into 1x1 mode." DEFVAL { false } ::= { cadSysParams 60 } cadSysFlapListInsertionThreshold OBJECT-TYPE SYNTAX Integer32 (60..86400) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object shows the number of seconds between successive ranging attempts that must pass before the modem is counted as flapped. The modem must have also been in a provisioning or registered state before the ranging request." DEFVAL { 180 } ::= { cadSysParams 61 } cadSysAES128Enable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enables AES-128 Cryptography Suite for BPI+ when true." DEFVAL { false } ::= { cadSysParams 62 } --=========== System Objects ============================== cadSysContact OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string." DEFVAL { "support@arris.com" } ::= { cadSysSystem 1 } cadSysName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string." ::= { cadSysSystem 2 } cadSysLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string." DEFVAL { "" } ::= { cadSysSystem 3 } --=========== Control Objects ============================= cadSysWriteMem OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This variable always returns FALSE upon reading. When set to TRUE, the configuration data currently resident in volatile memory (RAM) is written to persistent memory (NVRAM)." DEFVAL { false } ::= { cadSysControl 1 } cadSysEraseMem OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This variable always returns FALSE upon reading. When set to TRUE, the configuration data currently resident in persistent memory (NVRAM) is erased." DEFVAL { false } ::= { cadSysControl 2 } --=========== SNMP Objects ============================= cadSysEnableAuthenTraps OBJECT-TYPE SYNTAX INTEGER { enable(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the SNMP entity is permitted to generate authentication traps." ::= { cadSysSnmp 1 } cadSysSnmpReadAheadMax OBJECT-TYPE SYNTAX Unsigned32 (0..20) MAX-ACCESS read-write STATUS current DESCRIPTION "This value is the maximum number of records to read ahead" DEFVAL { 0 } ::= { cadSysSnmp 2 } cadSysSnmpRefreshTime OBJECT-TYPE SYNTAX Unsigned32 (0..1200) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This value represents how old a database record can be to be used." DEFVAL { 0 } ::= { cadSysSnmp 3 } cadSnmpRemoteEngineTable OBJECT-TYPE SYNTAX SEQUENCE OF CadSnmpRemoteEngineEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Table containing information of remote SNMP engines." ::= { cadSysSnmp 4 } cadSnmpRemoteEngineEntry OBJECT-TYPE SYNTAX CadSnmpRemoteEngineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing information of remote SNMP engines." INDEX { cadSnmpRemoteEngineIpAddress, cadSnmpRemoteEnginePortNumber } ::= { cadSnmpRemoteEngineTable 1 } CadSnmpRemoteEngineEntry ::= SEQUENCE { cadSnmpRemoteEngineIpAddress IpAddress, cadSnmpRemoteEnginePortNumber Integer32, cadSnmpRemoteEngineID SnmpEngineID, cadSnmpRemoteUserName SnmpAdminString, cadSnmpRemoteEngineType INTEGER, cadSnmpRemoteEngineStatus RowStatus } cadSnmpRemoteEngineIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IP address of a remote SNMP engine with which this user can communicate." ::= { cadSnmpRemoteEngineEntry 1 } cadSnmpRemoteEnginePortNumber OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The UDP port of a remote SNMP engine with which this user can communicate." ::= { cadSnmpRemoteEngineEntry 2 } cadSnmpRemoteEngineID OBJECT-TYPE SYNTAX SnmpEngineID MAX-ACCESS read-create STATUS deprecated DESCRIPTION "An SNMP engine's administratively-unique identifier of a remote SNMP engine with which this user can communicate." ::= { cadSnmpRemoteEngineEntry 3 } cadSnmpRemoteUserName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(1..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "A human readable string representing the name of the user of a remote SNMP engine." ::= { cadSnmpRemoteEngineEntry 4 } cadSnmpRemoteEngineType OBJECT-TYPE SYNTAX INTEGER { manual (1), auto (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type to indicate the remote engineID is manually configured or internally detected via SNMP V3 Informs probe response." DEFVAL { manual } ::= { cadSnmpRemoteEngineEntry 5 } cadSnmpRemoteEngineStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this conceptual row." ::= { cadSnmpRemoteEngineEntry 6 } --=========== Boot Param Objects ============================= cadSysBootMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION " Mac address of system controller " ::= { cadSysBootParams 1 } cadSysBootFpIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION " Ip address of E6000 front panel ethernet port " ::= { cadSysBootParams 2 } cadSysBootFpSubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION " E6000 front port interface subnet mask " ::= { cadSysBootParams 3 } cadSysBootDefaultGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION " Default gateway " ::= { cadSysBootParams 6 } cadSysBootTimeOffset OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Time offset (seconds) from UTC " ::= { cadSysBootParams 7 } cadSysBootTimeServer OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION " Ip address of TOD server " ::= { cadSysBootParams 8 } cadSysBootTimeServerConnType OBJECT-TYPE SYNTAX INTEGER { tcp(1), udp(2), none(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " Protocol (tcp/udp) used to connect to TOD server " DEFVAL { udp } ::= { cadSysBootParams 9 } cadSysBootStartupApplication OBJECT-TYPE SYNTAX INTEGER { bootprobe(1), bootapplication(4) } MAX-ACCESS read-only STATUS current DESCRIPTION " Startup mode of the E6000 " DEFVAL { bootapplication } ::= { cadSysBootParams 10 } cadSysBootStartupDelay OBJECT-TYPE SYNTAX Integer32 (1..60) MAX-ACCESS read-only STATUS current DESCRIPTION " Delay (in seconds) allowing changes before booting application " DEFVAL { 1 } ::= { cadSysBootParams 11 } cadSysBootSelection OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION " Bootloader to use (1 or 2) " DEFVAL { 1 } ::= { cadSysBootParams 12 } cadSysBootBaud OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION " Baud rate of front panel serial port " DEFVAL { 9600 } ::= { cadSysBootParams 13 } cadSysBootFpBIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION " Ip address of E6000 side B front panel ethernet port " ::= { cadSysBootParams 15 } cadSysBootParity OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-only STATUS current DESCRIPTION "Serial parity of console port. Valid values are N (no parity), E (even parity), and O (odd parity)." DEFVAL { "N" } ::= { cadSysBootParams 16 } --=========== Reload Control Objects ============================= cadSysReloadOperation OBJECT-TYPE SYNTAX INTEGER { reloadImage(1), reloadCommit(2), reloadActive(3), reloadHitless(4), reloadWritemem(5), reloadErasemem(6), reloadPatchInstall(7), reloadPatchRemove(8), reloadPatchApply(9), none(99) } MAX-ACCESS read-write STATUS current DESCRIPTION " Control object for E6000 reload, reading this object always returns none(99) " DEFVAL { none } ::= { cadSysReload 1 } cadSysReloadImageName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Image name to use in reloadImage operation " DEFVAL { "" } ::= { cadSysReload 2 } cadSysReloadStatus OBJECT-TYPE SYNTAX BITS { idle(0), inProgress(1), localCheckImage(2), localCommit(3), remoteCommit(4), remoteCopyImage(5), remoteCheckImage(6), patchInstall(7), localReboot(8), patchRemove(9), remoteFirmwareUpdate(10), firmwareUpdate(11), waitStandby(12), remotePatchInstall(13), writeMem(14), bundling(15), unbundling(16), complete(17), abort(18), remotePatchRemove(19), remoteWriteMem(20), eraseMem(21), remoteEraseMem(22), preloadCams(23), localInstallImage(24), remoteInstallImage(25), localPreloadRsm(26), remotePreloadRsm(27), remoteCommitRsm(28), copyImage(29), remoteFirmwareUpdateRsm(30), patchApplyCheck(31), waitSoftswitch(32), waitSpareCamsReset(33), waitCamsReset(34) } MAX-ACCESS read-only STATUS current DESCRIPTION " Status object for E6000 reload " DEFVAL { { idle } } ::= { cadSysReload 3 } cadSysReloadStatusDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Textual description of reload status " DEFVAL { "" } ::= { cadSysReload 4 } cadSysReloadPatchName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Patch image name to use in patch operations " DEFVAL { "" } ::= { cadSysReload 5 } --=========== Image Status Objects ============================= cadSysImageFile OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Image filename for current E6000 image " ::= { cadSysImage 1 } cadSysImageId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Image identifier for current E6000 image " ::= { cadSysImage 2 } cadSysImageName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Image name for current E6000 image " ::= { cadSysImage 3 } cadSysImageComponentCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Image component count for current E6000 image " ::= { cadSysImage 4 } --=========== Dictionary Objects ============================= cadSysDictionaryTable OBJECT-TYPE SYNTAX SEQUENCE OF CadSysDictionaryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Table describing internal state of database. " ::= { cadSysDictionary 1 } cadSysDictionaryEntry OBJECT-TYPE SYNTAX CadSysDictionaryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Describes the internal state of an individual table. " INDEX { cadSysDictionaryTableId } ::= { cadSysDictionaryTable 1 } CadSysDictionaryEntry ::= SEQUENCE { cadSysDictionaryTableId Unsigned32, cadSysDictionaryName DisplayString, cadSysDictionaryDynamic TruthValue, cadSysDictionaryNumberEntries Integer32, cadSysDictionaryCurrentVer Unsigned32, cadSysDictionaryPersistentVer Unsigned32, cadSysDictionaryModuleVer Unsigned32 } cadSysDictionaryTableId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Internal identifier for this MIB data." ::= { cadSysDictionaryEntry 1 } cadSysDictionaryName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Internal name for this MIB data." ::= { cadSysDictionaryEntry 2 } cadSysDictionaryDynamic OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether table is persistent or volatile only." ::= { cadSysDictionaryEntry 3 } cadSysDictionaryNumberEntries OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Current number of rows contained in the MIB table." ::= { cadSysDictionaryEntry 4 } cadSysDictionaryCurrentVer OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Current internal dynamic version number of the MIB table." ::= { cadSysDictionaryEntry 5 } cadSysDictionaryPersistentVer OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Current internal version number of the MIB table on flash." ::= { cadSysDictionaryEntry 6 } cadSysDictionaryModuleVer OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Current internal version number of the schema of the MIB table." ::= { cadSysDictionaryEntry 7 } --=========== Configuration Objects ============================= cadSysConfigSaveTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION " The date and time of the last write of the configuration to nvram. " ::= { cadSysConfiguration 1 } --== Class of Service to Quality of Service Mapping Objects ==== -- -- These cadCostoQosMapping objects only apply to 1.0 flows. -- To configure 1.1 flows, the objects in the docsQosParamSetTable -- should be used. -- cadCosToQosMappingTable OBJECT-TYPE SYNTAX SEQUENCE OF CadCosToQosMappingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of COS to QOS Mapping data" ::= { cadCosToQosMapping 9 } cadCosToQosMappingEntry OBJECT-TYPE SYNTAX CadCosToQosMappingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entry contains all of the data to map 1.0 COS to 1.1 QOS parameters." INDEX { cadCosToQosMappingIndex } ::= { cadCosToQosMappingTable 1 } CadCosToQosMappingEntry ::= SEQUENCE { cadCosToQosMappingIndex Integer32, cadCosUpMaxTrafficBurst Unsigned32, cadCosDnMaxTrafficBurst Unsigned32, cadCosDnMinReservedRate BitRate, cadCosUpMinReservedPkt Integer32, cadCosDnMinReservedPkt Integer32, cadCosUpTosAndMask OCTET STRING, cadCosUpTosOrMask OCTET STRING, cadCosDnMaxLatency Unsigned32, cadCosDnPriority Integer32, cadCosDnPeakTrafficRate BitRate, cadCosUpPeakTrafficRate BitRate } cadCosToQosMappingIndex OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMaxTrafficBurst" ::= { cadCosToQosMappingEntry 1 } cadCosUpMaxTrafficBurst OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMaxTrafficBurst" DEFVAL { 3044 } ::= { cadCosToQosMappingEntry 2 } cadCosDnMaxTrafficBurst OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The downstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMaxTrafficBurst" DEFVAL { 96000 } ::= { cadCosToQosMappingEntry 3 } cadCosDnMinReservedRate OBJECT-TYPE SYNTAX BitRate MAX-ACCESS read-write STATUS current DESCRIPTION "The downstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMinReservedRate" DEFVAL { 0 } ::= { cadCosToQosMappingEntry 4 } cadCosUpMinReservedPkt OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMinReservedPkt" DEFVAL { 0 } ::= { cadCosToQosMappingEntry 5 } cadCosDnMinReservedPkt OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The downstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMinReservedPkt" DEFVAL { 0 } ::= { cadCosToQosMappingEntry 6 } cadCosUpTosAndMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-write STATUS current DESCRIPTION "The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetTosAndMask" DEFVAL { 'ff'h } ::= { cadCosToQosMappingEntry 7 } cadCosUpTosOrMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-write STATUS current DESCRIPTION "The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetTosOrMask" DEFVAL { '00'h } ::= { cadCosToQosMappingEntry 8 } cadCosDnMaxLatency OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMaxLatency" DEFVAL { 0 } ::= { cadCosToQosMappingEntry 9 } cadCosDnPriority OBJECT-TYPE SYNTAX Integer32 (-1|0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "The downstream channel priority to use. A -1 indicates that the current method of using the upstream channel priority should be used." DEFVAL { -1 } ::= { cadCosToQosMappingEntry 10 } cadCosDnPeakTrafficRate OBJECT-TYPE SYNTAX BitRate MAX-ACCESS read-write STATUS current DESCRIPTION "Peak traffic rate shaped to while traffic still conforms to the policing parameters (Tmax and Burst). If the peak rate is set to a value greater than Tmax, then the traffic will be shaped to the peak rate until the traffic is non-conforming to the policing parameters, and then the traffic will be shaped to the Tmax rate. If the peak rate is less than the Tmax for a flow, then all traffic for that flow will shaped to the Tmax rate. Setting the peak rate to a value of 0 will result in all flows being limited to Tmax at all times. Setting the peak rate to a value of 0xffffffff will result in flows having virtually unlimited bandwidth until their burst size is used up. This parameter only has meaning for flows on downstreams that are shaped." DEFVAL { 0 } ::= { cadCosToQosMappingEntry 11 } cadCosUpPeakTrafficRate OBJECT-TYPE SYNTAX BitRate MAX-ACCESS read-write STATUS current DESCRIPTION "Peak traffic rate shaped to while traffic still conforms to the policing parameters (Tmax and Burst). If the peak rate is set to a value greater than Tmax, then the traffic will be shaped to the peak rate until the traffic is non-conforming to the policing parameters, and then the traffic will be shaped to the Tmax rate. If the peak rate is less than the Tmax for a flow, then all traffic for that flow will shaped to the Tmax rate. Setting the peak rate to a value of 0 will result in all flows being limited to Tmax at all times. Setting the peak rate to a value of 0xffffffff will result in flows having virtually unlimited bandwidth until their burst size is used up. This parameter only has meaning for upstream flows." DEFVAL { 0 } ::= { cadCosToQosMappingEntry 12 } --=========== Key Chain Objects ============================= cadSysKeyChainKeyTable OBJECT-TYPE SYNTAX SEQUENCE OF CadSysKeyChainKeyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Table describing key-chain key provisioned data. " ::= { cadSysKeyChain 1 } cadSysKeyChainKeyEntry OBJECT-TYPE SYNTAX CadSysKeyChainKeyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Describes the provisioned data for a key in a key-chain. " INDEX { cadSysKeyChainName, cadSysKeyChainKeySequenceId } ::= { cadSysKeyChainKeyTable 1 } CadSysKeyChainKeyEntry ::= SEQUENCE { cadSysKeyChainName OCTET STRING, cadSysKeyChainKeySequenceId Unsigned32, cadSysKeyChainKey OCTET STRING, cadSysKeyChainKeyAcceptStartTime DateAndTime, cadSysKeyChainKeyAcceptStopTime DateAndTime, cadSysKeyChainKeyAcceptInfiniteLifetime TruthValue, cadSysKeyChainKeySendStartTime DateAndTime, cadSysKeyChainKeySendStopTime DateAndTime, cadSysKeyChainKeySendInfiniteLifetime TruthValue, cadSysKeyChainKeyRowStatus RowStatus } cadSysKeyChainName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..16)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The key-chain name." ::= { cadSysKeyChainKeyEntry 1 } cadSysKeyChainKeySequenceId OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The sequence id of the key." ::= { cadSysKeyChainKeyEntry 2 } cadSysKeyChainKey OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..16)) MAX-ACCESS read-create STATUS current DESCRIPTION "The key string." ::= { cadSysKeyChainKeyEntry 3 } cadSysKeyChainKeyAcceptStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-create STATUS current DESCRIPTION "The start time when this key is valid for received packets." ::= { cadSysKeyChainKeyEntry 4 } cadSysKeyChainKeyAcceptStopTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-create STATUS current DESCRIPTION "The stop time when this key is no longer valid for received packets." ::= { cadSysKeyChainKeyEntry 5 } cadSysKeyChainKeyAcceptInfiniteLifetime OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "If this value is set to true, the key has an infinite lifetime for received packets. Otherwise use the accept start and stop time to determine the lifetime." DEFVAL { true } ::= { cadSysKeyChainKeyEntry 6 } cadSysKeyChainKeySendStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-create STATUS current DESCRIPTION "The start time when this key is valid for sending packets." ::= { cadSysKeyChainKeyEntry 7 } cadSysKeyChainKeySendStopTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-create STATUS current DESCRIPTION "The stop time when this key is no longer valid for sending packets." ::= { cadSysKeyChainKeyEntry 8 } cadSysKeyChainKeySendInfiniteLifetime OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "If this value is set to true, the key has an infinite lifetime for sending packets. Otherwise use the send start and stop time to determine the lifetime." DEFVAL { true } ::= { cadSysKeyChainKeyEntry 9 } cadSysKeyChainKeyRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted." ::= { cadSysKeyChainKeyEntry 10 } --=========== Processor Protocol Policing Objects ============================= -- configuration objects cadSysProcRouterControlGlobalPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted global protocol packet throttle rate to the Router Control processor." DEFVAL { 2500 } ::= { cadSysProcPolicingConfig 1 } cadSysProcArpPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted ARP packet rate to the Router Control processor." DEFVAL { 700 } ::= { cadSysProcPolicingConfig 2 } cadSysProcDhcpPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maxmimu permitted DHCP packet rate to the Router Control processor." DEFVAL { 750 } ::= { cadSysProcPolicingConfig 3 } cadSysProcIcmpPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted ICMP(IPv4) packet rate to the Router Control processor." DEFVAL { 500 } ::= { cadSysProcPolicingConfig 4 } cadSysProcOspfPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted OSPFv2 packet rate to the Router Control processor." DEFVAL { 750 } ::= { cadSysProcPolicingConfig 5 } cadSysProcRipPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted RIP packet rate to the Router Control processor." DEFVAL { 500 } ::= { cadSysProcPolicingConfig 6 } cadSysProcIgmpPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted IGMP packet rate to the Router Control processor." DEFVAL { 500 } ::= { cadSysProcPolicingConfig 7 } cadSysProcRouterControlOtherPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The other protocol packet rate to the Router Control processor." DEFVAL { 500 } ::= { cadSysProcPolicingConfig 8 } cadSysProcSnmpPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The SNMP packet rate to the System Control processor." DEFVAL { 650 } ::= { cadSysProcPolicingConfig 10 } cadSysProcTftpPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The TFTP packet rate to the processor." DEFVAL { 750 } ::= { cadSysProcPolicingConfig 11 } cadSysProcIsisPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The IS-IS packet rate to the processor." DEFVAL { 750 } ::= { cadSysProcPolicingConfig 12 } cadSysProcNdPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted Neighbor Discover (ND) packet throttle rate to the Router Control processor. This includes IPv6 Router Solicitation, Router Advertise, Neighbor Solicitation, Neighbor Advertise, and Redirect messages." DEFVAL { 700 } ::= { cadSysProcPolicingConfig 13 } cadSysProcDhcpIpv6PacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted DHCP (Ipv6) packet throttle rate to the Router Control processor." DEFVAL { 500 } ::= { cadSysProcPolicingConfig 14 } cadSysProcIcmpIpv6PacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted ICMP (Ipv6 other than Neighbor Discover and MLD) packet throttle rate to the Router Control processor." DEFVAL { 500 } ::= { cadSysProcPolicingConfig 15 } cadSysProcMldPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted MLD (version 1 and version 2) packet throttle rate to the Router Control processor." DEFVAL { 500 } ::= { cadSysProcPolicingConfig 16 } cadSysProcBgpPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted BGP packet throttle rate to the Router Control processor." DEFVAL { 500 } ::= { cadSysProcPolicingConfig 17 } cadSysProcPimPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted PIM packet throttle rate to the Router Control processor." DEFVAL { 100 } ::= { cadSysProcPolicingConfig 18 } cadSysProcSnmpCmPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted SNMP (from CMs) packet throttle rate to the Router Control processor." DEFVAL { 100 } ::= { cadSysProcPolicingConfig 19 } cadSysProcCopsPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted Cops packet throttle rate to the Router Control processor." DEFVAL { 300 } ::= { cadSysProcPolicingConfig 20 } cadSysProcTelnetPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted Telnet packet throttle rate to the Router Control processor." DEFVAL { 300 } ::= { cadSysProcPolicingConfig 21 } cadSysProcOspfv3PacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted OSPFv3 packet rate to the Router Control processor." DEFVAL { 750 } ::= { cadSysProcPolicingConfig 22 } cadSysProcTftpIpv6PacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The TFTP (IPv6) packet rate to the processor." DEFVAL { 750 } ::= { cadSysProcPolicingConfig 23 } cadSysProcEventIcmpPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted ICMP event packet rate to the Router Control processor." DEFVAL { 700 } ::= { cadSysProcPolicingConfig 24 } cadSysProcEventNoRoutePacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted No Route event packet rate to the Router Control processor." DEFVAL { 700 } ::= { cadSysProcPolicingConfig 25 } cadSysProcEventIcmpIpv6PacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted ICMP (IPv6) event packet rate to the Router Control processor." DEFVAL { 700 } ::= { cadSysProcPolicingConfig 26 } cadSysProcEventNoRouteIpv6PacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted No Route (IPv6) event packet rate to the Router Control processor." DEFVAL { 700 } ::= { cadSysProcPolicingConfig 27 } cadSysProcEventArpPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted ARP event packet rate to the Router Control processor." DEFVAL { 700 } ::= { cadSysProcPolicingConfig 28 } cadSysProcEventNdPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted ND event packet rate to the Router Control processor." DEFVAL { 700 } ::= { cadSysProcPolicingConfig 29 } cadSysProcEventTtlPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted TTL event packet rate to the Router Control processor." DEFVAL { 100 } ::= { cadSysProcPolicingConfig 30 } cadSysProcEventTtlIpv6PacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted TTL (IPv6) event packet rate to the Router Control processor." DEFVAL { 100 } ::= { cadSysProcPolicingConfig 31 } cadSysProcEventDadPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted DAD event packet rate to the Router Control processor." DEFVAL { 500 } ::= { cadSysProcPolicingConfig 32 } cadSysProcEventDefaultPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted Default event packet rate to the Router Control processor." DEFVAL { 3000 } ::= { cadSysProcPolicingConfig 33 } cadSysProcLdpPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The LDP (UDP and TCP) packet rate to the processor." DEFVAL { 750 } ::= { cadSysProcPolicingConfig 34 } cadSysProcClearPolicingCounts OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This variable always returns false(2) upon reading. When set to true(1), all objects under cadSysProcPolicingCounts are cleared." ::= { cadSysProcPolicingConfig 35 } cadSysProcLacpPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The total LACP packet rate to the processor." DEFVAL { 200 } ::= { cadSysProcPolicingConfig 36 } cadSysProcVrepPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted D6/VREP packet rate to the processor." DEFVAL { 500 } ::= { cadSysProcPolicingConfig 37 } cadSysProcVpmePacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted VPME packet rate to the processor." DEFVAL { 30 } ::= { cadSysProcPolicingConfig 38 } cadSysProcErmRpcPacketRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "packets/second" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum permitted RPC packet rate from an RPC ERM processor." DEFVAL { 300 } ::= { cadSysProcPolicingConfig 39 } -- -- count objects -- cadSysProcRouterControlGlobalPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets received passed to the Router Control processor." ::= { cadSysProcPolicingCounts 1 } cadSysProcRouterControlGlobalPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets received that are dropped by the Router Control processor." ::= { cadSysProcPolicingCounts 2 } cadSysProcArpPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ARP packets received passed to the processor." ::= { cadSysProcPolicingCounts 4 } cadSysProcArpPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ARP packets received that are dropped." ::= { cadSysProcPolicingCounts 5 } cadSysProcDhcpPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of DHCP packets received passed to the processor." ::= { cadSysProcPolicingCounts 7 } cadSysProcDhcpPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of DHCP packets received that are dropped." ::= { cadSysProcPolicingCounts 8 } -- cadSysProcDhcpPacketsSent removed. do NOT reuse the OID -- ::= { cadSysProcPolicingCounts 9 } cadSysProcIcmpPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ICMP packets received passed to the processor." ::= { cadSysProcPolicingCounts 10 } cadSysProcIcmpPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ICMP packets received that are dropped." ::= { cadSysProcPolicingCounts 11 } cadSysProcOspfPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of OSPFv2 packets received passed to the processor." ::= { cadSysProcPolicingCounts 13 } cadSysProcOspfPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of OSPFv2 packets received that are dropped." ::= { cadSysProcPolicingCounts 14 } cadSysProcRipPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RIP packets received passed to the processor." ::= { cadSysProcPolicingCounts 16 } cadSysProcRipPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RIP packets received that are dropped." ::= { cadSysProcPolicingCounts 17 } cadSysProcIgmpPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of IGMP packets received passed to the processor." ::= { cadSysProcPolicingCounts 19 } cadSysProcIgmpPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of IGMP packets received that are dropped." ::= { cadSysProcPolicingCounts 20 } cadSysProcRouterControlOtherPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of other packets received passed to the Router Control processor." ::= { cadSysProcPolicingCounts 22 } cadSysProcRouterControlOtherPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of other packets received that are dropped by the Router Control processor." ::= { cadSysProcPolicingCounts 23 } cadSysProcSnmpPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SNMP packets received passed to the System Control processor." ::= { cadSysProcPolicingCounts 25 } cadSysProcSnmpPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SNMP packets received that are dropped." ::= { cadSysProcPolicingCounts 26 } cadSysProcTftpPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of TFTP packets received passed to the processor." ::= { cadSysProcPolicingCounts 28 } cadSysProcTftpPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of TFTP packets received that are dropped." ::= { cadSysProcPolicingCounts 29 } cadSysProcIsisPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of IS-IS packets received passed to the processor." ::= { cadSysProcPolicingCounts 31 } cadSysProcIsisPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of IS-IS packets received that are dropped." ::= { cadSysProcPolicingCounts 32 } cadSysProcNdPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Neighbor Discover packets received passed to the processor." ::= { cadSysProcPolicingCounts 37 } cadSysProcNdPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Neighbor Discover packets received that are dropped." ::= { cadSysProcPolicingCounts 38 } cadSysProcDhcpIpv6PacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of DHCP(Ipv6) packets received passed to the processor." ::= { cadSysProcPolicingCounts 40 } cadSysProcDhcpIpv6PacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of DHCP(IPv6) packets received that are dropped." ::= { cadSysProcPolicingCounts 41 } cadSysProcIcmpIpv6PacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ICMP(Ipv6) packets received passed to the processor." ::= { cadSysProcPolicingCounts 43 } cadSysProcIcmpIpv6PacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ICMP(IPv6) packets received that are dropped." ::= { cadSysProcPolicingCounts 44 } cadSysProcMldPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of MLD packets received passed to the processor." ::= { cadSysProcPolicingCounts 46 } cadSysProcMldPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of MLD packets received that are dropped." ::= { cadSysProcPolicingCounts 47 } cadSysProcBgpPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of BGP packets received passed to the processor." ::= { cadSysProcPolicingCounts 49 } cadSysProcBgpPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of BGP packets received that are dropped." ::= { cadSysProcPolicingCounts 50 } cadSysProcPimPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PIM packets received passed to the processor." ::= { cadSysProcPolicingCounts 52 } cadSysProcPimPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PIM packets received that are dropped." ::= { cadSysProcPolicingCounts 53 } cadSysProcSnmpCmPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SNMP (from CMs) packets received passed to the processor." ::= { cadSysProcPolicingCounts 55 } cadSysProcSnmpCmPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SNMP (from CMs) packets received that are dropped." ::= { cadSysProcPolicingCounts 56 } cadSysProcCopsPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of COPS packets received passed to the System Control processor." ::= { cadSysProcPolicingCounts 58 } cadSysProcCopsPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of COPS packets received that are dropped." ::= { cadSysProcPolicingCounts 59 } cadSysProcTelnetPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of TELNET packets received passed to the System Control processor." ::= { cadSysProcPolicingCounts 61 } cadSysProcTelnetPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of TELNET packets received that are dropped." ::= { cadSysProcPolicingCounts 62 } cadSysProcOspfv3PacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of OSPFv3 packets received passed to the processor." ::= { cadSysProcPolicingCounts 64 } cadSysProcOspfv3PacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of OSPFv3 packets received that are dropped." ::= { cadSysProcPolicingCounts 65 } -- cadSysProcOspfv3PacketsSent removed -- ::= { cadSysProcPolicingCounts 66 } cadSysProcTftpIpv6PacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of TFTP (IPv6) packets received passed to the processor." ::= { cadSysProcPolicingCounts 67 } cadSysProcTftpIpv6PacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of TFTP (IPv6) packets received that are dropped." ::= { cadSysProcPolicingCounts 68 } -- cadSysProcTftpIpv6PacketsSent removed, do NOT reuse the OID -- ::= { cadSysProcPolicingCounts 69 } cadSysProcLdpPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of LDP (UDP and TCP) packets received passed to the processor." ::= { cadSysProcPolicingCounts 70 } cadSysProcLdpPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of LDP (UDP and TCP) packets received that are dropped." ::= { cadSysProcPolicingCounts 71 } -- cadSysProcLdpPacketsSent removed, do NOT reuse the OID -- ::= { cadSysProcPolicingCounts 72 } --=========== NPU events to the host Objects ============================== cadSysProcEventIcmpPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ICMP event packets received passed to the processor." ::= { cadSysProcPolicingCounts 73 } cadSysProcEventIcmpPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ICMP event packets received that are dropped." ::= { cadSysProcPolicingCounts 74 } cadSysProcEventNoRoutePacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of No Route event packets received passed to the processor." ::= { cadSysProcPolicingCounts 75 } cadSysProcEventNoRoutePacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of No Route event packets received that are dropped." ::= { cadSysProcPolicingCounts 76 } cadSysProcEventIcmpIpv6PacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ICMP (IPv6) event packets received passed to the processor." ::= { cadSysProcPolicingCounts 77 } cadSysProcEventIcmpIpv6PacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ICMP (IPv6) event packets received that are dropped." ::= { cadSysProcPolicingCounts 78 } cadSysProcEventNoRouteIpv6PacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of No Route (IPv6) event packets received passed to the processor." ::= { cadSysProcPolicingCounts 79 } cadSysProcEventNoRouteIpv6PacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of No Route (IPv6) event packets received that are dropped." ::= { cadSysProcPolicingCounts 80 } cadSysProcEventArpPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ARP event packets received passed to the processor." ::= { cadSysProcPolicingCounts 81 } cadSysProcEventArpPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ARP event packets received that are dropped." ::= { cadSysProcPolicingCounts 82 } cadSysProcEventNdPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ND event packets received passed to the processor." ::= { cadSysProcPolicingCounts 83 } cadSysProcEventNdPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ND event packets received that are dropped." ::= { cadSysProcPolicingCounts 84 } cadSysProcEventTtlPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of TTL event packets received passed to the processor." ::= { cadSysProcPolicingCounts 85 } cadSysProcEventTtlPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of TTL event packets received that are dropped." ::= { cadSysProcPolicingCounts 86 } cadSysProcEventTtlIpv6PacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of TTL (IPv6) event packets received passed to the processor." ::= { cadSysProcPolicingCounts 87 } cadSysProcEventTtlIpv6PacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of TTL (IPv6) event packets received that are dropped." ::= { cadSysProcPolicingCounts 88 } cadSysProcEventDadPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of DAD event packets received passed to the processor." ::= { cadSysProcPolicingCounts 89 } cadSysProcEventDadPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of DAD event packets received that are dropped." ::= { cadSysProcPolicingCounts 90 } cadSysProcEventDefaultPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Default event packets received passed to the processor." ::= { cadSysProcPolicingCounts 91 } cadSysProcEventDefaultPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Default event packets received that are dropped." ::= { cadSysProcPolicingCounts 92 } cadSysProcLacpPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of LACP packets received passed to the processor." ::= { cadSysProcPolicingCounts 93 } cadSysProcLacpPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of LACP packets received that are dropped." ::= { cadSysProcPolicingCounts 94 } cadSysProcVrepPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of D6/VREP packets received passed to the processor." ::= { cadSysProcPolicingCounts 95 } cadSysProcVrepPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of D6/VREP packets received that are dropped." ::= { cadSysProcPolicingCounts 96 } cadSysProcVpmePacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of VPME packets received passed to the processor." ::= { cadSysProcPolicingCounts 97 } cadSysProcVpmePacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of VPME packets received that are dropped." ::= { cadSysProcPolicingCounts 98 } cadSysProcErmRpcPacketsReceivedPassed OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ERM RPC packets received passed to the processor." ::= { cadSysProcPolicingCounts 99 } cadSysProcErmRpcPacketsReceivedDropped OBJECT-TYPE SYNTAX Counter32 UNITS "packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ERM RPC packets received that are dropped." ::= { cadSysProcPolicingCounts 100 } --=========== Banner Objects ============================== cadSysBannerMotdTable OBJECT-TYPE SYNTAX SEQUENCE OF CadSysBannerMotdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Table describing the MOTD banner that is displayed before the login: prompt" ::= { cadSysBanner 1 } cadSysBannerMotdEntry OBJECT-TYPE SYNTAX CadSysBannerMotdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Describes a line in the MOTD banner" INDEX { cadSysBannerMotdLine } ::= { cadSysBannerMotdTable 1 } CadSysBannerMotdEntry ::= SEQUENCE { cadSysBannerMotdLine Integer32, cadSysBannerMotdText DisplayString, cadSysBannerMotdRowStatus RowStatus } cadSysBannerMotdLine OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The line number" ::= { cadSysBannerMotdEntry 1 } cadSysBannerMotdText OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "The MOTD banner text" ::= { cadSysBannerMotdEntry 2 } cadSysBannerMotdRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted." ::= { cadSysBannerMotdEntry 3 } cadSysBannerLoginTable OBJECT-TYPE SYNTAX SEQUENCE OF CadSysBannerLoginEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Table describing the login banner that is displayed after the MOTD banner and before the login: prompt" ::= { cadSysBanner 2 } cadSysBannerLoginEntry OBJECT-TYPE SYNTAX CadSysBannerLoginEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Describes a line in the login banner" INDEX { cadSysBannerLoginLine } ::= { cadSysBannerLoginTable 1 } CadSysBannerLoginEntry ::= SEQUENCE { cadSysBannerLoginLine Integer32, cadSysBannerLoginText DisplayString, cadSysBannerLoginRowStatus RowStatus } cadSysBannerLoginLine OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The line number" ::= { cadSysBannerLoginEntry 1 } cadSysBannerLoginText OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "The login banner text" ::= { cadSysBannerLoginEntry 2 } cadSysBannerLoginRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted." ::= { cadSysBannerLoginEntry 3 } cadSysBannerExecTable OBJECT-TYPE SYNTAX SEQUENCE OF CadSysBannerExecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { cadSysBanner 3 } cadSysBannerExecEntry OBJECT-TYPE SYNTAX CadSysBannerExecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { cadSysBannerExecLine } ::= { cadSysBannerExecTable 1 } CadSysBannerExecEntry ::= SEQUENCE { cadSysBannerExecLine Integer32, cadSysBannerExecText DisplayString, cadSysBannerExecRowStatus RowStatus } cadSysBannerExecLine OBJECT-TYPE SYNTAX Integer32 (1..25) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of this banner line." ::= { cadSysBannerExecEntry 1 } cadSysBannerExecText OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "Ascii text of this banner line." ::= { cadSysBannerExecEntry 2 } cadSysBannerExecRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted." ::= { cadSysBannerExecEntry 3 } cadSysBannerIncomingTable OBJECT-TYPE SYNTAX SEQUENCE OF CadSysBannerIncomingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { cadSysBanner 4 } cadSysBannerIncomingEntry OBJECT-TYPE SYNTAX CadSysBannerIncomingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { cadSysBannerIncomingLine } ::= { cadSysBannerIncomingTable 1 } CadSysBannerIncomingEntry ::= SEQUENCE { cadSysBannerIncomingLine Integer32, cadSysBannerIncomingText DisplayString, cadSysBannerIncomingRowStatus RowStatus } cadSysBannerIncomingLine OBJECT-TYPE SYNTAX Integer32 (1..25) MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { cadSysBannerIncomingEntry 1 } cadSysBannerIncomingText OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= { cadSysBannerIncomingEntry 2 } cadSysBannerIncomingRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted." ::= { cadSysBannerIncomingEntry 3 } --=========== Server Objects ============================== cadSysServerTable OBJECT-TYPE SYNTAX SEQUENCE OF CadSysServerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Table describing the (INET) services that should run on the SCM." ::= { cadSysServer 1 } cadSysServerEntry OBJECT-TYPE SYNTAX CadSysServerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Describes an INET service and whether it is enabled " INDEX { cadSysServerType } ::= { cadSysServerTable 1 } CadSysServerEntry ::= SEQUENCE { cadSysServerType ServerType, cadSysServerAdminState AdminState } cadSysServerType OBJECT-TYPE SYNTAX ServerType MAX-ACCESS not-accessible STATUS current DESCRIPTION "The service type" ::= { cadSysServerEntry 1 } cadSysServerAdminState OBJECT-TYPE SYNTAX AdminState MAX-ACCESS read-create STATUS current DESCRIPTION "The administrative state of the server." DEFVAL { up } ::= { cadSysServerEntry 2 } --=========== Patch Parameter Objects ============================= cadSysPatchParamTable OBJECT-TYPE SYNTAX SEQUENCE OF CadSysPatchParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of patch parameters." ::= { cadSysPatchParams 1 } cadSysPatchParamEntry OBJECT-TYPE SYNTAX CadSysPatchParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of an individual patch parameter." INDEX { cadSysPatchParamIndex } ::= { cadSysPatchParamTable 1 } CadSysPatchParamEntry ::= SEQUENCE { cadSysPatchParamIndex Integer32, cadSysPatchParamName DisplayString, cadSysPatchParamValue DisplayString, cadSysPatchParamDescription DisplayString, cadSysPatchParamRowStatus RowStatus } cadSysPatchParamIndex OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The patch parameter index." ::= { cadSysPatchParamEntry 1 } cadSysPatchParamName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-create STATUS current DESCRIPTION "The patch parameter name." ::= { cadSysPatchParamEntry 2 } cadSysPatchParamValue OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-create STATUS current DESCRIPTION "The patch parameter value." ::= { cadSysPatchParamEntry 3 } cadSysPatchParamDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-create STATUS current DESCRIPTION "The patch parameter description." ::= { cadSysPatchParamEntry 4 } cadSysPatchParamRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted." ::= { cadSysPatchParamEntry 5 } --=========== Maintenance Configuration ============================== cadSysMtceStatusCloneMonitorThreshold OBJECT-TYPE SYNTAX Unsigned32 (2750..6250) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Timeout during normal operation." DEFVAL { 6000 } ::= { cadSysMtceParams 8 } cadSysMtceStatusCloneInitThreshold OBJECT-TYPE SYNTAX Unsigned32 (3000..9000) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Timeout on initialization for first status message." DEFVAL { 7500 } ::= { cadSysMtceParams 9 } cadSysMtceStatusCloneRcvyThreshold OBJECT-TYPE SYNTAX Unsigned32 (120000..360000) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Timeout following clone side recovery." DEFVAL { 240000 } ::= { cadSysMtceParams 10 } cadSysMtceBasePingRate OBJECT-TYPE SYNTAX Unsigned32 (750..2250) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Interval between system maintenance polling of monitored threads." DEFVAL { 2000 } ::= { cadSysMtceParams 11 } cadSysMtceOvSensitivity OBJECT-TYPE SYNTAX OverloadThreshold MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the sensitivity of user overload to changes in internal work load. Higher sensitivity results in more rapid change of user overload in response to a change in the internal work load." DEFVAL { med } ::= { cadSysMtceParams 12 } cadSysMtceOvThreshold OBJECT-TYPE SYNTAX OverloadThreshold MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the overall threshold of user overload transitions. Higher thresholds require a longer time in an internal overload state before user overload transitions occur." DEFVAL { med } ::= { cadSysMtceParams 13 } cadSysMtceDULPacketInterval OBJECT-TYPE SYNTAX Unsigned32(0|10000..900000) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Interval between maintenance polling of monitored BroadCom devices. Setting the value to zero will disable BroadCom device monitoring." DEFVAL { 10000 } ::= { cadSysMtceParams 14 } --=========== Data Management ==============================-- cadSysDataServerDataTimeout OBJECT-TYPE SYNTAX Unsigned32 (50000..500000) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Time allowed for Data Query/Update to be processed." DEFVAL { 50000 } ::= { cadSysDataServer 1 } cadSysDataServerDataEventsPerCycle OBJECT-TYPE SYNTAX Unsigned32 (10..200) UNITS "events/cycle" MAX-ACCESS read-write STATUS current DESCRIPTION "Number of data events allowed per cycle." DEFVAL { 40 } ::= { cadSysDataServer 2 } cadSysDataServerDataSyncTimeout OBJECT-TYPE SYNTAX Unsigned32 (8000..100000) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Number of data events allowed per cycle." DEFVAL { 80000 } ::= { cadSysDataServer 3 } cadSysDataServerSnmpReadAheadEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "When this value is set to true Snmp read ahead is performed." DEFVAL { true } ::= { cadSysDataServer 4 } cadSysDataServerSnmpReadAheadMax OBJECT-TYPE SYNTAX Unsigned32 (0..20) MAX-ACCESS read-write STATUS current DESCRIPTION "This value is the maximum number of records to read ahead" DEFVAL { 1 } ::= { cadSysDataServer 5 } cadSysDataServerSnmpRefreshTime OBJECT-TYPE SYNTAX Unsigned32 (1..1200) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This value represents how old a database record can be to be used." DEFVAL { 1 } ::= { cadSysDataServer 6 } cadSysDataServerSyncDataEventsPerCycle OBJECT-TYPE SYNTAX Unsigned32 (40..100) UNITS "events/cycle" MAX-ACCESS read-write STATUS current DESCRIPTION "This value is the maximum number of Sync events that will be processed per cycle." DEFVAL { 40 } ::= { cadSysDataServer 7 } cadSysDataServerLoPriDataEventsPerCycle OBJECT-TYPE SYNTAX Unsigned32 (10..100) UNITS "events/cycle" MAX-ACCESS read-write STATUS current DESCRIPTION "This value is the maximum number of Low Priority Sync events to be processed per cycle." DEFVAL { 10 } ::= { cadSysDataServer 8 } --============================ Source Interface and Address =========================== cadSysSourceAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF CadSysSourceAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of source interface addresses for administrative services" ::= { cadSysSourceAddress 1 } cadSysSourceAddressEntry OBJECT-TYPE SYNTAX CadSysSourceAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entry contains the configured source IPv4 and/or IPv6 address for each administrative service. If configured, it also contains the global default address." INDEX { cadSysSourceAddressIndex } ::= { cadSysSourceAddressTable 1 } CadSysSourceAddressEntry ::= SEQUENCE { cadSysSourceAddressIndex AdminSrcAddrType, cadSysSourceInterfaceIpv4IfIndex InterfaceIndexOrZero, cadSysSourceAddressIpv4Address InetAddressIPv4, cadSysSourceInterfaceIpv6IfIndex InterfaceIndexOrZero, cadSysSourceAddressIpv6Address InetAddressIPv6 } cadSysSourceAddressIndex OBJECT-TYPE SYNTAX AdminSrcAddrType MAX-ACCESS not-accessible STATUS current DESCRIPTION "The type of administrative service." ::= { cadSysSourceAddressEntry 1 } cadSysSourceInterfaceIpv4IfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-write STATUS current DESCRIPTION "The ifIndex of the interface from which all IPv4 packets are sourced. For a server service, it is also the only DIP allowed for incoming requests. A value of 0 indicates no source interface override." DEFVAL { 0 } ::= { cadSysSourceAddressEntry 2 } cadSysSourceAddressIpv4Address OBJECT-TYPE SYNTAX InetAddressIPv4 MAX-ACCESS read-only STATUS current DESCRIPTION "The IPv4 address of the IPv4 interface at the time the row ipv4 ifIndex was populated. Used as the source address for the service if the state is in-service. For a server service, it is also the only DIP allowed for incoming requests. A value of null indicates no source address has been assigned." DEFVAL { "" } ::= { cadSysSourceAddressEntry 3 } cadSysSourceInterfaceIpv6IfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-write STATUS current DESCRIPTION "The ifIndex of the interface from which all IPv6 packets are sourced (not currently supported). For a server service, it is also the only DIP allowed for incoming requests. A value of 0 indicates no source interface override." DEFVAL { 0 } ::= { cadSysSourceAddressEntry 4 } cadSysSourceAddressIpv6Address OBJECT-TYPE SYNTAX InetAddressIPv6 MAX-ACCESS read-only STATUS current DESCRIPTION "The IPv6 address of the IPv6 interface at the time the ipv6 ifIndex was populated. Used as the source address for the service if the state is in-service. For a server service, it is also the only DIP allowed for incoming requests. A value of null indicates no source address has been assigned." DEFVAL { "" } ::= { cadSysSourceAddressEntry 5} --========================== License Control ==========================-- cadSysLicenseCardId OBJECT-TYPE SYNTAX CardId MAX-ACCESS not-accessible STATUS current DESCRIPTION "CAM to be licensed." DEFVAL { 0 } ::= { cadSysLicenseControl 1 } cadSysLicenseKey OBJECT-TYPE SYNTAX OCTET STRING (SIZE (16)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "License key to apply to the CAM." DEFVAL { ''h } ::= { cadSysLicenseControl 2 } cadSysLicensePorts OBJECT-TYPE SYNTAX Integer32(0..5000) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of CAM ports associated with the license." DEFVAL { 0 } ::= { cadSysLicenseControl 3 } cadSysLicenseAnnex OBJECT-TYPE SYNTAX INTEGER { unknown(1), other(2), annexA(3), annexB(4), annexC(5) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "This attribute defines the ITU-J-83 Annex being used for this E6000 CMTS License." DEFVAL { unknown } ::= { cadSysLicenseControl 4 } cadSysLicenseStatus OBJECT-TYPE SYNTAX INTEGER { success(1), fail(2), pending(3), none(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of licensing operation." DEFVAL { none } ::= { cadSysLicenseControl 5 } --============================ LAES Mediation Device Timestamp Mode Table =========================== cadLaesMdTimestampModeTable OBJECT-TYPE SYNTAX SEQUENCE OF CadLaesMdTimestampModeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of LAES Mediation Device Timestamp mode table" ::= { cadLaesMdTimestampMode 1 } cadLaesMdTimestampModeEntry OBJECT-TYPE SYNTAX CadLaesMdTimestampModeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This entry contains the configured MD IPv4. If configured, then all encapsulated tap packets going to that MD will contain a timestamp in the tap header." INDEX { cadLaesMdTimestampModeInetAddrType, cadLaesMdTimestampModeInetAddr} ::= { cadLaesMdTimestampModeTable 1 } CadLaesMdTimestampModeEntry ::= SEQUENCE { cadLaesMdTimestampModeInetAddrType InetAddressType, cadLaesMdTimestampModeInetAddr InetAddress, cadLaesMdTimestampModRowStatus RowStatus } cadLaesMdTimestampModeInetAddrType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IP Address type of Mediation Device" ::= { cadLaesMdTimestampModeEntry 1 } cadLaesMdTimestampModeInetAddr OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IP Address of the Mediation Device." ::= { cadLaesMdTimestampModeEntry 2 } cadLaesMdTimestampModRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The row status of this entry" ::= { cadLaesMdTimestampModeEntry 3 } ---========================= cadSysMICSecondarySecretTable ==========================-- cadSysMICSecondarySecretTable OBJECT-TYPE SYNTAX SEQUENCE OF CadSysMICSecondarySecretEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table containing secondary shared secret strings for cable modem configuration file authentication. This table is not used unless cadSysMICEnable is set to true." ::= { cadSysSharedSecret 1 } cadSysMICSecondarySecretEntry OBJECT-TYPE SYNTAX CadSysMICSecondarySecretEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing secondary shared secret strings for cable modem configuration file authentication." INDEX { cadSysMICSecondarySecretIndex } ::= { cadSysMICSecondarySecretTable 1 } CadSysMICSecondarySecretEntry ::= SEQUENCE { cadSysMICSecondarySecretIndex INTEGER, cadSysMICSecondarySecretString OCTET STRING, cadSysMICSecondarySecretStatus RowStatus } cadSysMICSecondarySecretIndex OBJECT-TYPE SYNTAX INTEGER (1..1) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Internal index for this MIB row." ::= { cadSysMICSecondarySecretEntry 1 } cadSysMICSecondarySecretString OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..64)) MAX-ACCESS read-create STATUS current DESCRIPTION " Encrypted MIC Authentication shared secret string." ::= { cadSysMICSecondarySecretEntry 2 } cadSysMICSecondarySecretStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this conceptual row." ::= { cadSysMICSecondarySecretEntry 3 } --- --- Conformance information --- cadSystemMibConformance OBJECT IDENTIFIER ::= { cadSystemMib 12 } cadSystemCompliances OBJECT IDENTIFIER ::= { cadSystemMibConformance 1 } cadSystemGroups OBJECT IDENTIFIER ::= { cadSystemMibConformance 2 } cadSystemCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance statement for entities implementing the Cadant System Mib." MODULE -- this module MANDATORY-GROUPS { cadSysParamsGroup, cadSysSystemGroup, cadSysControlGroup, cadSysSnmpGroup, cadSysBootParamsGroup, cadSysReloadGroup, cadSysImageGroup, cadSysDataServerGroup, cadSysSourceAddressGroup } ::= { cadSystemCompliances 1 } cadSysParamsGroup OBJECT-GROUP OBJECTS { cadSysSyncInterval, cadSysUCDInterval, cadSysMaxMAPPending, cadSysRangingInterval, cadSysInvitedRangingRetries, cadSysRegistrationRequestRetries, cadSysCMMAPProcessingTime, cadSysCMConfiguration, cadSysT5Timeout, cadSysT6Timeout, cadSysMiniSlotSize, cadSysDSxRequestRetries, cadSysT7Timeout, cadSysT8Timeout, cadSysT9Timeout, cadSysT10Timeout, cadSysT11Timeout, cadSysT13Timeout, cadSysDCCREQRetries, cadSysMICEnable, cadSysMICAuthString, cadSysAutoRecoveryEnable, cadSysActiveIpAddress, cadSysSpOperMode, cadSysMaxQoSActiveTimeout, cadSysMaxQoSAdmittedTimeout, cadSysAllow10CmConcatenation, cadSysAllow10CmFragmentation, cadSysPercentAddtlDsBwAllocated, cadSysMaxTrafBurstFor11CMs, cadSysRemoteFSEnable, cadSysRemotePortEnable, cadSysTcpSmoothingValue1D8U, cadSysTcpSmoothingValue2D12U, cadSysModemLossThreshold, cadSysPeakTrafRateFor11CMs, cadSysCpeHostAuthorization } STATUS current DESCRIPTION "System parameter objects" ::= { cadSystemGroups 1 } cadSysSystemGroup OBJECT-GROUP OBJECTS { cadSysContact, cadSysName, cadSysLocation } STATUS current DESCRIPTION "System description objects" ::= { cadSystemGroups 2 } cadSysControlGroup OBJECT-GROUP OBJECTS { cadSysWriteMem, cadSysEraseMem } STATUS deprecated DESCRIPTION "System control objects" ::= { cadSystemGroups 3 } cadSysSnmpGroup OBJECT-GROUP OBJECTS { cadSysEnableAuthenTraps, cadSysSnmpReadAheadMax, cadSysSnmpRefreshTime } STATUS current DESCRIPTION "System snmp control object" ::= { cadSystemGroups 4 } cadSysBootParamsGroup OBJECT-GROUP OBJECTS { cadSysBootMacAddress, cadSysBootFpIpAddress, cadSysBootFpSubnetMask, cadSysBootDefaultGateway, cadSysBootTimeOffset, cadSysBootTimeServer, cadSysBootTimeServerConnType, cadSysBootStartupApplication, cadSysBootStartupDelay, cadSysBootSelection } STATUS current DESCRIPTION "System boot parameters objects" ::= { cadSystemGroups 5 } cadSysReloadGroup OBJECT-GROUP OBJECTS { cadSysReloadImageName, cadSysReloadOperation, cadSysReloadStatus } STATUS current DESCRIPTION "System reload control objects" ::= { cadSystemGroups 6 } cadSysImageGroup OBJECT-GROUP OBJECTS { cadSysImageFile, cadSysImageId, cadSysImageName, cadSysImageComponentCount } STATUS current DESCRIPTION "System image status objects" ::= { cadSystemGroups 7 } cadSysConfigurationGroup OBJECT-GROUP OBJECTS { cadSysConfigSaveTime } STATUS current DESCRIPTION "Configuration objects" ::= { cadSystemGroups 8 } cadSysDataServerGroup OBJECT-GROUP OBJECTS { cadSysDataServerDataTimeout, cadSysDataServerDataEventsPerCycle, cadSysDataServerDataSyncTimeout, cadSysDataServerSnmpReadAheadEnable, cadSysDataServerSnmpReadAheadMax, cadSysDataServerSnmpRefreshTime, cadSysDataServerSyncDataEventsPerCycle, cadSysDataServerLoPriDataEventsPerCycle } STATUS current DESCRIPTION "Configuration objects" ::= { cadSystemGroups 9 } cadSysSourceAddressGroup OBJECT-GROUP OBJECTS { cadSysSourceInterfaceIpv4IfIndex, cadSysSourceAddressIpv4Address, cadSysSourceInterfaceIpv6IfIndex, cadSysSourceAddressIpv6Address } STATUS current DESCRIPTION "Source Interface objects." ::= { cadSystemGroups 10 } END -- end of CADANT-CMTS-SYSTEM-MIB