-- Copyright (C) 2010-2012 Aricent Group . All Rights Reserved -- $Id: fsmspw.mib,v 1.2 2012/09/07 09:52:05 siva Exp $ Aricent-MSPW-MIB DEFINITIONS ::= BEGIN IMPORTS PwIndexType, PwOperStatusTC FROM PW-TC-STD-MIB MODULE-IDENTITY, OBJECT-TYPE, enterprises,Unsigned32 FROM SNMPv2-SMI RowStatus FROM SNMPv2-TC; fsMspwMIB MODULE-IDENTITY LAST-UPDATED "201209050000Z" ORGANIZATION "ARICENT COMMUNICATIONS SOFTWARE" CONTACT-INFO "support@aricent.com" DESCRIPTION "All rights reserved" REVISION "201209050000Z" -- 15 March 2006 10:00:00 IST DESCRIPTION "The Proprietary MIB for MSPW module" ::= { enterprises aricent-communication-holding-ltd(29601) iss(2) 57} fsMsPwConfigObjects OBJECT IDENTIFIER ::= { fsMspwMIB 1 } -- Multi Segment Pseudo Wire Table(MS-PW) starts fsMsPwMaxEntries OBJECT-TYPE SYNTAX Unsigned32 (1..32766) MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of MS-PW entries are supported." DEFVAL { 64 } ::= { fsMsPwConfigObjects 1 } fsMsPwConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF FsMsPwConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies information for configuring and monitoring Multi Segment Pseudo Wire at S-PE." ::= { fsMsPwConfigObjects 2 } fsMsPwConfigEntry OBJECT-TYPE SYNTAX FsMsPwConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in this table represents Pseudo Wire cross connection between packet switched network domains. It is indexed by fsMsPwIndex1 and fsMsPwIndex2 which uniquely identifies a single Pseudo wire cross connection. None of the read-create objects values can be changed when fsMsPwRowStatus is in the active(1) state. Changes are allowed when the fsMsPwRowStatus is in notInService(2) or notReady(3) states only. If the operator need to change one of the values for an active row the fsMsPwRowStatus should be first changed to notInService(2), the objects may be changed now, and later to active(1) in order to re-initiate the signaling process with the new values in effect. " INDEX { fsMsPwIndex1,fsMsPwIndex2} ::= { fsMsPwConfigTable 1 } FsMsPwConfigEntry ::= SEQUENCE { fsMsPwIndex1 PwIndexType, fsMsPwIndex2 PwIndexType, fsMsPwOperStatus PwOperStatusTC, fsMsPwRowStatus RowStatus } fsMsPwIndex1 OBJECT-TYPE SYNTAX PwIndexType MAX-ACCESS not-accessible STATUS current DESCRIPTION "Primay Index for the conceptual row identifying received pseudo wire at S-PE. It is referred to a received pwIndex in the pwTable" ::= { fsMsPwConfigEntry 1 } fsMsPwIndex2 OBJECT-TYPE SYNTAX PwIndexType MAX-ACCESS not-accessible STATUS current DESCRIPTION " Seconday Index for the conceptual row identifying the transmitted pseudowire at S-PE. It is referred to a transmitted pwIndex in the pwTable " ::= { fsMsPwConfigEntry 2 } fsMsPwOperStatus OBJECT-TYPE SYNTAX PwOperStatusTC MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the operational status of the PW cross connection,It is said to be UP only when both segment of the cross connected pseudo wire is UP,otherwise it will be Down. " ::= { fsMsPwConfigEntry 3 } fsMsPwRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "For creating, modifying, and deleting this row. For making a row available for use [Active State], valid PWIndices are Mandatory." ::= { fsMsPwConfigEntry 4 } -- Multi Segment Pseudo Wire Table(MS-PW) ends END