-- Copyright (C) 2015 Aricent. All Rights Reserved -- $Id: fspbt.mib,v 1.5 2016/02/18 09:47:31 siva Exp $ -- PBB-TE Proprietary MIB Definition -- This document explains the proprietary MIB implemented -- for PBB-TE product. -- This proprietary MIB definition, supplements the standard IEEE802.1Qay -- MIB and also provides management of certain proprietary features of -- PBB-TE. -- The proprietary MIB definitions follows: ARICENT-PBB-TE-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE,MODULE-IDENTITY, Integer32, Unsigned32, enterprises, Counter32 FROM SNMPv2-SMI RowStatus, MacAddress FROM SNMPv2-TC VlanId FROM ARICENTQ-BRIDGE-MIB ieee8021PbbTeTeSidEntry, IfIndexList FROM IEEE8021-PBBTE-MIB; fspbbte MODULE-IDENTITY LAST-UPDATED "201209050000Z" ORGANIZATION "ARICENT COMMUNICATIONS SOFTWARE" CONTACT-INFO "support@aricent.com" DESCRIPTION "The proprietary MIB module for PBB-TE module." REVISION "201209050000Z" DESCRIPTION "The proprietary MIB module for PBB-TE module." ::= { enterprises aricent-communication-holding-ltd(29601) iss(2) 11} -- **************************************************************************** -- Groups in the MIB -- **************************************************************************** fsPbbTeScalars OBJECT IDENTIFIER ::= { fspbbte 1 } fsPbbTeContext OBJECT IDENTIFIER ::= { fspbbte 2 } fsPbbTeEspVidMapping OBJECT IDENTIFIER ::= { fspbbte 3 } fsPbbTeTeSidExtension OBJECT IDENTIFIER ::= { fspbbte 4 } fsPbbTeTest OBJECT IDENTIFIER ::= { fspbbte 5 } -- **************************************************************************** -- Scalars in the MIB -- **************************************************************************** fsPbbTeGlobalTraceOption OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to enable trace statements in PBB-TE module for global events that are not specific to any virtual context. A four byte integer is used for enabling the trace level. Each bit in the four byte integer represents a particular trace level. Trace Levels BIT 0 - Init and Shutdown traces 1 - Management traces 2 - Data Path traces 3 - Control Plane traces 4 - Packet Dump traces 5 - Traces related to all resources except buffers 6 - All Failure traces 7 - Buffer allocation/release traces The remaining bits are reserved to be used for module specific trace options." ::= { fsPbbTeScalars 1 } -- **************************************************************************** -- Context Based table -- **************************************************************************** fsPbbTeContextTable OBJECT-TYPE SYNTAX SEQUENCE OF FsPbbTeContextEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains Provider Backbone Bridge - Traffic engineering configuration for each context running in the switch." ::= { fsPbbTeContext 1 } fsPbbTeContextEntry OBJECT-TYPE SYNTAX FsPbbTeContextEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains context number and the PBB-TE configuration for the particular context." INDEX { fsPbbTeContextId } ::= { fsPbbTeContextTable 1 } FsPbbTeContextEntry ::= SEQUENCE { fsPbbTeContextId Integer32, fsPbbTeContextSystemControl INTEGER, fsPbbTeContextTraceOption Unsigned32, fsPbbTeContextNoOfActiveEsps Counter32, fsPbbTeContextNoOfCreatedEsps Counter32, fsPbbTeContextNoOfDeletedEsps Counter32 } fsPbbTeContextId OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Identifies Virtual Context in the system." ::= { fsPbbTeContextEntry 1 } fsPbbTeContextSystemControl OBJECT-TYPE SYNTAX INTEGER { start(1), shutdown(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Start or shutdown Provider Backbone Brige-Traffic Engg in the system. When set as 'start', resources required by PBB-TE module are allocated & PBB-TE module starts running. When shutdown, all resources used by PBB-TE module will be released to the mempool." ::= { fsPbbTeContextEntry 2 } fsPbbTeContextTraceOption OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to enable trace statements in PBB-TE module for events specific to a context. A four byte integer is used for enabling the trace level. Each bit in the four byte integer represents a particular trace level. Trace Levels BIT 0 - Init and Shutdown traces 1 - Management traces 2 - Data Path traces 3 - Control Plane traces 4 - Packet Dump traces 5 - Traces related to all resources except buffers 6 - All Failure traces 7 - Buffer allocation/release traces The remaining bits are reserved to be used for module specific trace options." ::= { fsPbbTeContextEntry 3 } fsPbbTeContextNoOfActiveEsps OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the number of current active ESPs existing in the given virtual context." ::= { fsPbbTeContextEntry 4 } fsPbbTeContextNoOfCreatedEsps OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ESPs that has been created in the given virtual context, since creation of the context." ::= { fsPbbTeContextEntry 5 } fsPbbTeContextNoOfDeletedEsps OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of ESPs that has been deleted in the given virtual context, since creation of the context." ::= { fsPbbTeContextEntry 6 } -- **************************************************************************** -- ESP-VIDs Table -- **************************************************************************** fsPbbTeEspVidTable OBJECT-TYPE SYNTAX SEQUENCE OF FsPbbTeEspVidEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains ESP Vlans in this bridge." ::= { fsPbbTeEspVidMapping 1 } fsPbbTeEspVidEntry OBJECT-TYPE SYNTAX FsPbbTeEspVidEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ESP Vlans configured in this bridge." INDEX { fsPbbTeContextId, fsPbbTeEspVid } ::= { fsPbbTeEspVidTable 1 } FsPbbTeEspVidEntry ::= SEQUENCE { fsPbbTeEspVid VlanId, fsPbbTeEspVidRowStatus RowStatus } fsPbbTeEspVid OBJECT-TYPE SYNTAX VlanId MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object specifies the Vlan identifier allocated for provisioning TE Ethernet switched paths." ::= { fsPbbTeEspVidEntry 1 } fsPbbTeEspVidRowStatus OBJECT-TYPE SYNTAX RowStatus { createAndGo(4), destroy(6) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object specifies the status of this entry. A Vlan ID can be marked as an ESP-VID by creating and activating an entry in this table i.e. by assigning a value of 'createAndGo' for the status. Every Vlan index which has a status of 'active' is an ESP-VID. A Vlan that is marked as an ESP VLAN in this manner should not be deleted without reverting it back to a non-ESP VID first. This is done by setting the status as 'destroy'." ::= { fsPbbTeEspVidEntry 2 } -- **************************************************************************** -- TE-SID Extension Table -- **************************************************************************** fsPbbTeTeSidExtTable OBJECT-TYPE SYNTAX SEQUENCE OF FsPbbTeTeSidExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is extension of standard ieee8021PbbTeTeSidTable." ::= { fsPbbTeTeSidExtension 1 } fsPbbTeTeSidExtEntry OBJECT-TYPE SYNTAX FsPbbTeTeSidExtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries in this table are the extension entries of ieee8021PbbTeTeSidTable." AUGMENTS { ieee8021PbbTeTeSidEntry } ::= { fsPbbTeTeSidExtTable 1 } FsPbbTeTeSidExtEntry ::= SEQUENCE { fsPbbTeTeSidExtContextId Integer32 } fsPbbTeTeSidExtContextId OBJECT-TYPE SYNTAX Integer32 (-1|0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Identifies Virtual Context in the system. If the TESID entry is not assigned to any virtual context then it will have a value of -1." DEFVAL {-1} ::= { fsPbbTeTeSidExtEntry 1 } -- **************************************************************************** -- Test Mib objects -- -- The following MIB objects are used only for test purposes -- **************************************************************************** -- The following Mib objects are used to test the API provided by PBB-TE -- for dynamic provisioning from external modules fsPbbTeTestApiContextId OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Identifies Virtual Context in the system." ::= { fsPbbTeTest 1 } fsPbbTeTestApiTeSid OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Traffic-engineering Service-instance identifier. Specifying TE-SID is optional when creating an ESP. If TE-SID is not provided, a Vlan Static Filtering entry alone will be created for the ESP." ::= { fsPbbTeTest 2 } fsPbbTeTestApiDestMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Destination Mac Address of the ESP." ::= { fsPbbTeTest 3 } fsPbbTeTestApiSourceMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Source Mac Address of the ESP. Specifying Source MAC address is optional when creating an ESP. It is mandatory only when the TESID is specified. Otherwise it is not used." ::= { fsPbbTeTest 4 } fsPbbTeTestApiEspVlanId OBJECT-TYPE SYNTAX VlanId MAX-ACCESS read-write STATUS current DESCRIPTION "Vlan Id that has been allocated as an ESP vlan." ::= { fsPbbTeTest 5 } fsPbbTeTestApiEgressPort OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Egress port for point to point ESPs. If the Egress port is configured as zero, then the EgressPortList will be referred." ::= { fsPbbTeTest 6 } fsPbbTeTestApiEgressPortList OBJECT-TYPE SYNTAX IfIndexList MAX-ACCESS read-write STATUS current DESCRIPTION "EgreePortList in case of port to multipoint ESPs. This object will be referred only when the EgressPort is configured as zero." ::= { fsPbbTeTest 7 } fsPbbTeTestApiAction OBJECT-TYPE SYNTAX INTEGER { create(1), destroy(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the status of this entry. When this object is configured, the PBB-TE API for ESP creation will be invoked with the last configured values for the test API MIB objects. Also all test API MIB objects will be reset to have a value of zero ready for the next invocation." ::= { fsPbbTeTest 8 } END