-- **************************************************************************** -- * APC cPDU SNMP MIB DEFINITIONS -- * $Date: 25 NOVEMBER 2021 10:00:00 $ -- * $Revision: 1.3 $ -- Revised -- Confidential - Need To Know -- **************************************************************************** -- -- APC cPDU SNMP -- Management Information Base for SNMP Network Management for PDU -- -- Copyright (c) 2021 APC -- -- The APC Enterprise number is 318. -- The ASN.1 prefix to, and including the APC is: -- 1.3.6.1.4.1.318 -- -- MIB Version 1.3 -- -- ********************************************************************* -- Release History -- Updated the CASCADING OID DESCRIPTION -- Updated the OID Description for OLED Orientation -- -- ********************************************************************* -- =================================================================================== -- sysDescr (1.3.6.1.2.1.1.1) which is defined in RFC1213.MIB. -- sysObjectID (1.3.6.1.2.1.1.2) which is defined in RFC1213.MIB. -- sysContact (1.3.6.1.2.1.1.4) which is defined in RFC1213.MIB. -- sysName (1.3.6.1.2.1.1.5) is which is defined in RFC1213.MIB. -- sysLocation (1.3.6.1.2.1.1.6) which is defined in RFC1213.MIB. -- -- sysDescr OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..255)) -- ACCESS read-only -- STATUS mandatory -- DESCRIPTION -- "A textual description of the entity. This value -- should include the full name, hardware version and -- firmware version of management module's. -- It is mandatory that this only contain -- printable ASCII characters." -- ::= { system 1 } -- -- sysObjectID OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..255)) -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- "Return the OID of the management module for PDU defined in the APC.MIB -- i.e. .1.3.6.1.4.1.318.1.1.32 is for OIDs." -- ::= { system 2 } -- -- sysContact OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..255)) -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- "The textual identification of the contact person -- for this managed node, together with information -- on how to contact this person." -- ::= { system 4 } -- -- sysName OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..255)) -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- "An administratively-assigned name for this -- managed node. By convention, this is the node's -- fully-qualified domain name." -- ::= { system 5 } -- -- sysLocation OBJECT-TYPE -- SYNTAX DisplayString (SIZE (0..255)) -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- "The physical location of this node (e.g., -- `telephone closet, 3rd floor')." -- ::= { system 6 } -- -- ==================================================================================== -- -- ==================================================================================== CPDU-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, IpAddress, Gauge, TimeTicks FROM RFC1155-SMI DisplayString FROM RFC1213-MIB SnmpAdminString FROM SNMP-FRAMEWORK-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 InetAddressType FROM INET-ADDRESS-MIB InetAddress FROM INET-ADDRESS-MIB MacAddress FROM SNMPv2-TC; -- IMPORTS End apc OBJECT IDENTIFIER ::= { enterprises 318 } products OBJECT IDENTIFIER ::= { apc 1 } hardware OBJECT IDENTIFIER ::= { products 1 } cPDU OBJECT IDENTIFIER ::= { hardware 32 } -- ++++ Start of cPDU ++++ pduNamePlate OBJECT IDENTIFIER ::= { cPDU 1 } pduUnit OBJECT IDENTIFIER ::= { cPDU 2 } pduInputPhase OBJECT IDENTIFIER ::= { cPDU 3 } pduCircuitBreaker OBJECT IDENTIFIER ::= { cPDU 4 } pduOutlet OBJECT IDENTIFIER ::= { cPDU 5 } pduExternalSensor OBJECT IDENTIFIER ::= { cPDU 6 } pduSmartCabinet OBJECT IDENTIFIER ::= { cPDU 7 } pduTraps OBJECT IDENTIFIER ::= { cPDU 8 } pduEhandle OBJECT IDENTIFIER ::= { cPDU 9 } -- Start pduNamePlate pduNamePlateTableSize OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of PDUs" ::= { pduNamePlate 1 } -- pduNamePlateTable pduNamePlateTable OBJECT-TYPE SYNTAX SEQUENCE OF PduNamePlateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU nameplate data" ::= { pduNamePlate 2 } pduNamePlateEntry OBJECT-TYPE SYNTAX PduNamePlateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Nameplate data from the PDU being queried. The numbers of entries equals the value of pduNamePlateTableSize." INDEX { pduNamePlateIndex } ::= { pduNamePlateTable 1 } PduNamePlateEntry ::= SEQUENCE { pduNamePlateIndex Integer32, pduNamePlateName DisplayString, pduNamePlateLocation DisplayString, pduNamePlateInetAddressType INTEGER, pduNamePlateIPAddress InetAddress, pduNamePlateInetNetMask InetAddress, pduNamePlateInetGateway InetAddress, pduNamePlateMACAddress MacAddress, pduNamePlateUTCTimeOffset DisplayString, pduNamePlateModelNumber DisplayString, pduNamePlatePartNumber DisplayString, pduNamePlateSerialNumber DisplayString, pduNamePlateDateofManufacture DisplayString, pduNamePlateFirmwareVersion DisplayString, pduNamePlateFirmwareVersionTimeStamp DisplayString, pduNamePlateType INTEGER } pduNamePlateIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU nameplate table entry" ::= { pduNamePlateEntry 1 } pduNamePlateName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A user-defined string identifying the PDU" ::= { pduNamePlateEntry 2 } pduNamePlateLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A user-defined string identifying the location of PDU" ::= { pduNamePlateEntry 3 } pduNamePlateInetAddressType OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The type of address format" ::= { pduNamePlateEntry 4 } pduNamePlateIPAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The current IP address. A value of 0.0.0.0 indicates an error or an unset option" ::= { pduNamePlateEntry 5 } pduNamePlateInetNetMask OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The current netmask. A value of 0.0.0.0 indiates an error or an unset option" ::= { pduNamePlateEntry 6 } pduNamePlateInetGateway OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The current gateway. A value of 0.0.0.0 indicates an error or an unset option" ::= { pduNamePlateEntry 7 } pduNamePlateMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The assigned MAC address for the PDU" ::= { pduNamePlateEntry 8 } pduNamePlateUTCTimeOffset OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The difference in hours and minutes from Coordinated Universal Time(UTC) for the time used in a particular time zone" ::= { pduNamePlateEntry 9 } pduNamePlateModelNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The PDU model number" ::= { pduNamePlateEntry 10 } pduNamePlatePartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The PDU part number" ::= { pduNamePlateEntry 11 } pduNamePlateSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The PDU serial number" ::= { pduNamePlateEntry 12 } pduNamePlateDateofManufacture OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The date the PDU was manufactured in mm/dd/yyyy format" ::= { pduNamePlateEntry 13 } pduNamePlateFirmwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The PDU firmware version" ::= { pduNamePlateEntry 14 } pduNamePlateFirmwareVersionTimeStamp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp of when the PDU firmware was last updated" ::= { pduNamePlateEntry 15 } pduNamePlateType OBJECT-TYPE SYNTAX INTEGER {singlePhase (1),delta (2),wye (3)} MAX-ACCESS read-only STATUS current DESCRIPTION "The type of input" ::= { pduNamePlateEntry 16 } -- Start pduUnit pduUnitTableSize OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of units." ::= { pduUnit 1 } pduUnitConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF PduUnitConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU configuration data" ::= { pduUnit 2 } pduUnitConfigEntry OBJECT-TYPE SYNTAX PduUnitConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration data from the PDU being queried. The number of entries equals the value of pduUnitTableSize" INDEX { pduUnitConfigIndex } ::= { pduUnitConfigTable 1 } PduUnitConfigEntry ::= SEQUENCE { pduUnitConfigIndex Integer32, pduUnitConfigName DisplayString, pduUnitConfigLocation DisplayString, pduUnitConfigDisplayOrientation INTEGER, pduUnitConfigOledDisplayControl INTEGER, pduUnitConfigColdstartDelay Unsigned32, pduUnitConfigGlobalOutletStateOnStartup INTEGER, pduUnitConfigLowerCriticalThreshold Unsigned32, pduUnitConfigLowerWarningThreshold Unsigned32, pduUnitConfigUpperCriticalThreshold Unsigned32, pduUnitConfigUpperWarningThreshold Unsigned32, pduUnitConfigAlarmResetThreshold Unsigned32, pduUnitConfigAlarmStateChangeDelay Unsigned32, pduUnitConfigEnabledThresholds BITS, pduUnitConfigPeakPowerReset INTEGER, pduUnitConfigEnergyReset INTEGER, pduUnitConfigOutletPeakPowerReset INTEGER, pduUnitConfigOutletEnergyReset INTEGER, pduUnitConfigSsh INTEGER, pduUnitConfigResetNetworkManagementCard INTEGER, } pduUnitConfigIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU Unit Config Entry" ::= { pduUnitConfigEntry 1 } pduUnitConfigName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A user-defined string identifying the PDU" ::= { pduUnitConfigEntry 2 } pduUnitConfigLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A user-defined string identifying the location of the PDU" ::= { pduUnitConfigEntry 3 } pduUnitConfigDisplayOrientation OBJECT-TYPE SYNTAX INTEGER { displayNormal (1), displayReverse (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the intended physical orientation of the oLED display displayNormal (1) indicates normal orientation. displayReverse (2) indicates upside down orientation NOTE: This OID is compatible only with the two display NMC module. It does not work with the single display NMC module." ::= { pduUnitConfigEntry 4 } pduUnitConfigOledDisplayControl OBJECT-TYPE SYNTAX INTEGER { displayOff (1), displayOn (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to turn oled display On or Off displayOff (1) to turn dispaly OFF. displayOn (2) to turn dispaly ON" ::= { pduUnitConfigEntry 5 } pduUnitConfigColdstartDelay OBJECT-TYPE SYNTAX Unsigned32 (0..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "The amount of time, specified in seconds, between when power is provided to the PDU and when the PDU start providing basic master power to the outlets" ::= { pduUnitConfigEntry 6 } pduUnitConfigGlobalOutletStateOnStartup OBJECT-TYPE SYNTAX INTEGER { off (0), on (1), lastKnownState (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The outlet state on device startup; applies to all outlets unless overridden at the outlet level" ::= { pduUnitConfigEntry 7 } pduUnitConfigLowerCriticalThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined lower critical unit active power alarm threshold measured in Watts" ::= { pduUnitConfigEntry 8 } pduUnitConfigLowerWarningThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined lower non-critical (warning) unit active power alarm threshold measured in Watts" ::= { pduUnitConfigEntry 9 } pduUnitConfigUpperCriticalThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined upper critical unit active power alarm threshold measured in Watts" ::= { pduUnitConfigEntry 10 } pduUnitConfigUpperWarningThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined upper non-critical (warning) unit active power alarm threshold measured in Watts" ::= { pduUnitConfigEntry 11 } pduUnitConfigAlarmResetThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The hysteresis used for deassertions in Watts" ::= { pduUnitConfigEntry 12 } pduUnitConfigAlarmStateChangeDelay OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The delay measured in samples before a state is asserted. If the value is zero, then the state is asserted as soon as it is detected; if it is non-zero, say n, then the assertion condition must exist for n+1 consecutive samples before the corresponding assertion event is reported." ::= { pduUnitConfigEntry 13 } pduUnitConfigEnabledThresholds OBJECT-TYPE SYNTAX BITS { lowerCritical (0), lowerWarning (1), upperWarning (2), upperCritical (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "A bit string indicating which alarm thresholds are enabled" ::= { pduUnitConfigEntry 14 } pduUnitConfigPeakPowerReset OBJECT-TYPE SYNTAX INTEGER { noOperation (1), reset (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this OID to reset (2) will cause the existing peak power value to be replaced by the current load power value. Getting this OID will do nothing and return the noOperation(1) value. " ::= { pduUnitConfigEntry 15 } pduUnitConfigEnergyReset OBJECT-TYPE SYNTAX INTEGER { noOperation (1), reset (2), notSupported (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this OID to reset (2) will cause the device energy meter value to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail. " ::= { pduUnitConfigEntry 16 } pduUnitConfigOutletPeakPowerReset OBJECT-TYPE SYNTAX INTEGER { noOperation (1), reset (2), notSupported (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this OID to reset (2) will cause the outlet peak power meter value to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail. " ::= { pduUnitConfigEntry 17 } pduUnitConfigOutletEnergyReset OBJECT-TYPE SYNTAX INTEGER { noOperation (1), reset (2), notSupported (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this OID to reset (2) will cause the outlet energy meter value to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail. " ::= { pduUnitConfigEntry 18 } pduUnitConfigSsh OBJECT-TYPE SYNTAX INTEGER { off (0), on (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this OID to off(0) will disable the SSH connection. Setting this OID to on(1) will enable the SSH connection." ::= { pduUnitConfigEntry 19 } pduUnitConfigResetNetworkManagementCard OBJECT-TYPE SYNTAX INTEGER { noOperation (0), reset (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Getting this OID will return noOperation(0). Setting this OID to reset(1) will reset NMC." ::= { pduUnitConfigEntry 20 } pduUnitPropertiesTable OBJECT-TYPE SYNTAX SEQUENCE OF PduUnitPropertiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU properties" ::= { pduUnit 3 } pduUnitPropertiesEntry OBJECT-TYPE SYNTAX PduUnitPropertiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unit properties entry containing objects for a particular unit." INDEX { pduUnitPropertiesIndex } ::= { pduUnitPropertiesTable 1 } PduUnitPropertiesEntry ::= SEQUENCE { pduUnitPropertiesIndex Integer32, pduUnitPropertiesName DisplayString, pduUnitPropertiesOutletCount Integer32, pduUnitPropertiesSwitchedOutletCount Integer32, pduUnitPropertiesMeteredOutletCount Integer32, pduUnitPropertiesInputPhaseCount Integer32, pduUnitPropertiesCircuitBreakerCount Integer32, pduUnitPropertiesMaxExternalSensorCount Integer32, pduUnitPropertiesConnExternalSensorCount Integer32, pduUnitPropertiesRatedVoltage DisplayString, pduUnitPropertiesRatedMaxCurrent DisplayString, pduUnitPropertiesRatedFrequency DisplayString, pduUnitPropertiesRatedPower DisplayString, pduUnitPropertiesOrientation INTEGER, pduUnitPropertiesOutletLayout INTEGER, pduUnitPropertiesCascadeMemberType INTEGER, } pduUnitPropertiesIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU properties table entry" ::= { pduUnitPropertiesEntry 1 } pduUnitPropertiesName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A user-defined string identifying the PDU" ::= { pduUnitPropertiesEntry 2 } pduUnitPropertiesOutletCount OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of outlets on the PDU" ::= { pduUnitPropertiesEntry 3 } pduUnitPropertiesSwitchedOutletCount OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of switched outlets on the PDU" ::= { pduUnitPropertiesEntry 4 } pduUnitPropertiesMeteredOutletCount OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of metered outlets on the PDU" ::= { pduUnitPropertiesEntry 5 } pduUnitPropertiesInputPhaseCount OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of phases on the PDU" ::= { pduUnitPropertiesEntry 6 } pduUnitPropertiesCircuitBreakerCount OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of circuit breaker on the PDU" ::= { pduUnitPropertiesEntry 7 } pduUnitPropertiesMaxExternalSensorCount OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of external sensors that can be connected to the PDU" ::= { pduUnitPropertiesEntry 8 } pduUnitPropertiesConnExternalSensorCount OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The current number of external sensors connected to the PDU" ::= { pduUnitPropertiesEntry 9 } pduUnitPropertiesRatedVoltage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The PDU voltage rating in Volts" ::= { pduUnitPropertiesEntry 10 } pduUnitPropertiesRatedMaxCurrent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The PDU current rating in Amps" ::= { pduUnitPropertiesEntry 11 } pduUnitPropertiesRatedFrequency OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The PDU frequency rating in Hz" ::= { pduUnitPropertiesEntry 12 } pduUnitPropertiesRatedPower OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The PDU VA (VoltAmps) rating." ::= { pduUnitPropertiesEntry 13 } pduUnitPropertiesOrientation OBJECT-TYPE SYNTAX INTEGER { horizontal (1), vertical (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The PDU orientation " ::= { pduUnitPropertiesEntry 14 } pduUnitPropertiesOutletLayout OBJECT-TYPE SYNTAX INTEGER { seqPhaseToNuetral (1), seqPhaseToPhase (2), seqPhToNeu21PhToPh (3), seqPhToPhGrouped (4), seqPhToNGrouped (5), seqPToN1516PToPGrouped (6), seqPhToPh2xGrouped (7), seqPhToN2xGrouped (8), seqNotApplicable (9) } MAX-ACCESS read-only STATUS current DESCRIPTION "The outlet layout for the PDU. Getting this OID will return outlet layout for the device. seqPhaseToNeutral(1) indicates outlet layout as follows: 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... seqPhaseToPhase(2) indicates outlet layout as follows: 1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,... seqPhToNeu21PhToPh(3) indicates outlet layout as follows: 1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,... seqPhToPhGrouped(4) indicates outlet layout as follows: This unit has 3 outlet groups. Group 1:1-2, Group 2:2-3, Group 3:3-1. seqPhToNGrouped(5) indicates outlet layout as follows: This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N. seqPToN1516PToPGrouped(6) indicates outlet layout as follows: This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2, Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1. seqPhToPh2xGrouped(7) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3, Group 4:2-3, Group 5:3-1, Group 6:3-1. seqPhToN2xGrouped(8) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N, Group 4:2-N, Group 5:3-N, Group 6:3-N. seqNotApplicable(9):" ::= { pduUnitPropertiesEntry 15 } pduUnitPropertiesCascadeMemberType OBJECT-TYPE SYNTAX INTEGER { standalone (1), parent (2), child (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The cascading member type" ::= { pduUnitPropertiesEntry 16 } pduUnitStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF PduUnitStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU status information" ::= { pduUnit 4 } pduUnitStatusEntry OBJECT-TYPE SYNTAX PduUnitStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Status information from the PDU being queried" INDEX { pduUnitStatusIndex } ::= { pduUnitStatusTable 1 } PduUnitStatusEntry ::= SEQUENCE { pduUnitStatusIndex Integer32, pduUnitStatusName DisplayString, pduUnitStatusLoadState INTEGER, pduUnitStatusActivePower Integer32, pduUnitStatusApparentPower Integer32, pduUnitStatusPeakPower Integer32, pduUnitStatusPeakPowerTimestamp DisplayString, pduUnitStatusPeakPowerStartTime DisplayString, pduUnitStatusEnergy Integer32, pduUnitStatusResettableEnergy Integer32, pduUnitStatusEnergyStartTime DisplayString, pduUnitStatusOutletsEnergyStartTime DisplayString } pduUnitStatusIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU status table entry" ::= { pduUnitStatusEntry 1 } pduUnitStatusName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A user-defined string identifying the PDU" ::= { pduUnitStatusEntry 2 } pduUnitStatusLoadState OBJECT-TYPE SYNTAX INTEGER { upperCritical (1), upperWarning (2), lowerWarning (3), lowerCritical (4), normal (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the present load status of the PDU based on Active Power." ::= { pduUnitStatusEntry 3 } pduUnitStatusActivePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Returns power consumption, in Watts(W), of the PDU being queried." ::= { pduUnitStatusEntry 4 } pduUnitStatusApparentPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Returns power consumption, in Volt-Amps(VA) of the PDU load being queried." ::= { pduUnitStatusEntry 5 } pduUnitStatusPeakPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Returns peak power consumption, in Watts(W), of the PDU being queried." ::= { pduUnitStatusEntry 6 } pduUnitStatusPeakPowerTimestamp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the date and time that peak power consumption occurred" ::= { pduUnitStatusEntry 7 } pduUnitStatusPeakPowerStartTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the date and time of the last device peak power reset" ::= { pduUnitStatusEntry 8 } pduUnitStatusEnergy OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Returns total energy consumed, in tenths of Kilowatt-Hours(kWh), of the PDU over its lifetime." ::= { pduUnitStatusEntry 9 } pduUnitStatusResettableEnergy OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A user resettable energy meter measuring PDU energy consumption in tenths of kilowatt-hours(kWh)." ::= { pduUnitStatusEntry 10 } pduUnitStatusEnergyStartTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the date and time of the last device energy meter reset" ::= { pduUnitStatusEntry 11 } pduUnitStatusOutletsEnergyStartTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the date and time of the last outlets energy meter reset" ::= { pduUnitStatusEntry 12 } -- Power share table pduUnitPsTable OBJECT-TYPE SYNTAX SEQUENCE OF PduUnitPsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Aggregate Object with number of entries equal to number of PDUs and Power share " ::= { pduUnit 5} pduUnitPsEntry OBJECT-TYPE SYNTAX PduUnitPsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Power share entry containing the avaliable, input, output etc." INDEX { pduUnitPsIndex } ::= { pduUnitPsTable 1 } PduUnitPsEntry ::= SEQUENCE { pduUnitPsIndex INTEGER, pduUnitPsSupportUpstreamStatus INTEGER, pduUnitPsSupportDownstreamStatus INTEGER, pduUnitPsOptMode INTEGER } pduUnitPsIndex OBJECT-TYPE SYNTAX INTEGER (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PDU Power share table entry" ::= { pduUnitPsEntry 1 } pduUnitPsSupportUpstreamStatus OBJECT-TYPE SYNTAX INTEGER { notAvailable(0), available(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Power share support status on upstream PDU " ::= { pduUnitPsEntry 2} pduUnitPsSupportDownstreamStatus OBJECT-TYPE SYNTAX INTEGER { notAvailable(0), available(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Power share support status on downstream PDU " ::= { pduUnitPsEntry 3 } pduUnitPsOptMode OBJECT-TYPE SYNTAX INTEGER { backupPower(0), mainPower(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Operating power status. " ::= { pduUnitPsEntry 4 } -- Start pduInputPhase pduInputPhaseTableSize OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PDU Input Phases " ::= { pduInputPhase 1 } pduInputPhaseConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF PduInputPhaseConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU Input Phase configuration data" ::= { pduInputPhase 2 } pduInputPhaseConfigEntry OBJECT-TYPE SYNTAX PduInputPhaseConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An input phase entry containing objects for a particular input phase." INDEX { pduUnitConfigIndex, pduInputPhaseConfigIndex } ::= { pduInputPhaseConfigTable 1 } PduInputPhaseConfigEntry ::= SEQUENCE { pduInputPhaseConfigIndex Integer32, pduInputPhaseConfigCount Integer32, pduInputPhaseConfigOverloadRestriction INTEGER, pduInputPhaseConfigCurrentLowerCriticalThreshold Unsigned32, pduInputPhaseConfigCurrentLowerWarningThreshold Unsigned32, pduInputPhaseConfigCurrentUpperCriticalThreshold Unsigned32, pduInputPhaseConfigCurrentUpperWarningThreshold Unsigned32, pduInputPhaseConfigVoltageLowerCriticalThreshold Unsigned32, pduInputPhaseConfigVoltageLowerWarningThreshold Unsigned32, pduInputPhaseConfigVoltageUpperCriticalThreshold Unsigned32, pduInputPhaseConfigVoltageUpperWarningThreshold Unsigned32, pduInputPhaseConfigCurrentAlarmResetThreshold Unsigned32, pduInputPhaseConfigCurrentAlarmStateChangeDelay Integer32, pduInputPhaseConfigCurrentEnabledThresholds BITS, pduInputPhaseConfigVoltageAlarmResetThreshold Unsigned32, pduInputPhaseConfigVoltageAlarmStateChangeDelay Integer32, pduInputPhaseConfigVoltageEnabledThresholds BITS } pduInputPhaseConfigIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU Input Phase configuration table entry" ::= { pduInputPhaseConfigEntry 1 } pduInputPhaseConfigCount OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of Input Phases" ::= { pduInputPhaseConfigEntry 2 } pduInputPhaseConfigOverloadRestriction OBJECT-TYPE SYNTAX INTEGER { alwaysAllowTurnOn (1), restrictOnUpperWarning (2), restrictOnUpperCritical (3), notSupported (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This OID controls the behavior of a Switched PDU Input Phase when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding Input Phase to turn on. Setting this OID to restrictOnUpperWarning (2) will not allow outlets on the corresponding Input Phase to turn on if the pduInputPhaseConfigUpperWarningThreshold OID is exceeded. Setting this OID to restrictOnUpperCritical (3) will not allow outlets on the corresponding Input Phase to turn on if the pduInputPhaseConfigUpperCriticalThreshold OID is exceeded. Models that do not support this feature will respond to this OID with a value of notSupported (4). Attempts to set this OID in these models will fail. " ::= { pduInputPhaseConfigEntry 3 } pduInputPhaseConfigCurrentLowerCriticalThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined lower critical input phase current alarm threshold in hundredths of Amps(A)." ::= { pduInputPhaseConfigEntry 4 } pduInputPhaseConfigCurrentLowerWarningThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined lower non-critical (warning) input phase current alarm threshold in hundredths of Amps(A)." ::= { pduInputPhaseConfigEntry 5 } pduInputPhaseConfigCurrentUpperCriticalThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined upper critical input phase current alarm threshold in hundredths of Amps(A)." ::= { pduInputPhaseConfigEntry 6 } pduInputPhaseConfigCurrentUpperWarningThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined upper non-critical (warning) input phase current alarm threshold in hundredths of Amps(A)." ::= { pduInputPhaseConfigEntry 7 } pduInputPhaseConfigVoltageLowerCriticalThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined lower critical input phase voltage alarm threshold in Volts(V)." ::= { pduInputPhaseConfigEntry 8 } pduInputPhaseConfigVoltageLowerWarningThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined lower non-critical (warning) input phase voltage alarm threshold in Volts(V)." ::= { pduInputPhaseConfigEntry 9 } pduInputPhaseConfigVoltageUpperCriticalThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined upper critical input phase voltage alarm threshold in Volts(V)." ::= { pduInputPhaseConfigEntry 10 } pduInputPhaseConfigVoltageUpperWarningThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined upper non-critical (warning) input phase voltage alarm threshold in Volts(V)." ::= { pduInputPhaseConfigEntry 11 } pduInputPhaseConfigCurrentAlarmResetThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The hysteresis used for current alarm deassertions in hundredths of Amps(A)." ::= { pduInputPhaseConfigEntry 12 } pduInputPhaseConfigCurrentAlarmStateChangeDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The delay measured in samples before a current state is asserted. If the value is zero, then the state is asserted as soon as it is detected; if it is non-zero, say n, then the assertion condition must exist for n+1 consecutive samples before the corresponding assertion event is reported. " ::= { pduInputPhaseConfigEntry 13 } pduInputPhaseConfigCurrentEnabledThresholds OBJECT-TYPE SYNTAX BITS { lowerCritical (0), lowerWarning (1), upperWarning (2), upperCritical (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "A bit string indicating which current alarm thresholds are enabled." ::= { pduInputPhaseConfigEntry 14 } pduInputPhaseConfigVoltageAlarmResetThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The hysteresis used for voltage alarm deassertions in Volts(V)." ::= { pduInputPhaseConfigEntry 15 } pduInputPhaseConfigVoltageAlarmStateChangeDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The delay measured in samples before a voltage state is asserted. If the value is zero, then the state is asserted as soon as it is detected; if it is non-zero, say n, then the assertion condition must exist for n+1 consecutive samples before the corresponding assertion event is reported. " ::= { pduInputPhaseConfigEntry 16 } pduInputPhaseConfigVoltageEnabledThresholds OBJECT-TYPE SYNTAX BITS { lowerCritical (0), lowerWarning (1), upperWarning (2), upperCritical (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "A bit string indicating which voltage alarm thresholds are enabled." ::= { pduInputPhaseConfigEntry 17 } pduInputPhasePropertiesTable OBJECT-TYPE SYNTAX SEQUENCE OF PduInputPhasePropertiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU Input Phase properties" ::= { pduInputPhase 3 } pduInputPhasePropertiesEntry OBJECT-TYPE SYNTAX PduInputPhasePropertiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An input phase properties entry containing objects for a particular input phase." INDEX { pduUnitPropertiesIndex, pduInputPhasePropertiesIndex } ::= { pduInputPhasePropertiesTable 1 } PduInputPhasePropertiesEntry ::= SEQUENCE { pduInputPhasePropertiesIndex Integer32, pduInputPhasePropertiesCount Integer32 } pduInputPhasePropertiesIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU Input Phase status entry" ::= { pduInputPhasePropertiesEntry 1 } pduInputPhasePropertiesCount OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The numeric Input Phase ID" ::= { pduInputPhasePropertiesEntry 2 } pduInputPhaseStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF PduInputPhaseStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU Input Phase status data" ::= { pduInputPhase 4 } pduInputPhaseStatusEntry OBJECT-TYPE SYNTAX PduInputPhaseStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An input phase status entry containing objects for a particular input phase." INDEX { pduUnitStatusIndex, pduInputPhaseStatusIndex } ::= { pduInputPhaseStatusTable 1 } PduInputPhaseStatusEntry ::= SEQUENCE { pduInputPhaseStatusIndex Integer32, pduInputPhaseStatusCount Integer32, pduInputPhaseStatusCurrentState INTEGER, pduInputPhaseStatusVoltageState INTEGER, pduInputPhaseStatusCurrent Integer32, pduInputPhaseStatusVoltage Integer32, pduInputPhaseStatusActivePower Integer32, pduInputPhaseStatusApparentPower Integer32, pduInputPhaseStatusPowerFactor Integer32 } pduInputPhaseStatusIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU Input Phase status entry" ::= { pduInputPhaseStatusEntry 1 } pduInputPhaseStatusCount OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The numeric Input Phase ID" ::= { pduInputPhaseStatusEntry 2 } pduInputPhaseStatusCurrentState OBJECT-TYPE SYNTAX INTEGER { upperCritical (1), upperWarning (2), lowerWarning (3), lowerCritical (4), normal (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the present current status of the PDU Phase in case of Y connection or PDU Line in case of Delta conneciton." ::= { pduInputPhaseStatusEntry 3 } pduInputPhaseStatusVoltageState OBJECT-TYPE SYNTAX INTEGER { upperCritical (1), upperWarning (2), lowerWarning (3), lowerCritical (4), normal (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the present voltage status of the PDU Input Phase being queried" ::= { pduInputPhaseStatusEntry 4 } pduInputPhaseStatusCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the current draw, in hundredths of Amps(A)" ::= { pduInputPhaseStatusEntry 5 } pduInputPhaseStatusVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the voltage, in Volts(V)" ::= { pduInputPhaseStatusEntry 6 } pduInputPhaseStatusActivePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Returns power consumption, in Watts(W)" ::= { pduInputPhaseStatusEntry 7 } pduInputPhaseStatusApparentPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Returns power consumption, in Volt-Amps(VA)" ::= { pduInputPhaseStatusEntry 8 } pduInputPhaseStatusPowerFactor OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the ratio of active to apparent power of the PDU." ::= { pduInputPhaseStatusEntry 9 } -- Start pduCircuitBreaker pduCircuitBreakerTableSize OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PDU Circuit Breakers" ::= { pduCircuitBreaker 1 } pduCircuitBreakerConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF PduCircuitBreakerConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU Circuit Breaker configuration data" ::= { pduCircuitBreaker 2 } pduCircuitBreakerConfigEntry OBJECT-TYPE SYNTAX PduCircuitBreakerConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A circuit breaker configuration entry containing objects for a particular circuit breaker." INDEX { pduUnitConfigIndex, pduCircuitBreakerConfigIndex } ::= { pduCircuitBreakerConfigTable 1 } PduCircuitBreakerConfigEntry ::= SEQUENCE { pduCircuitBreakerConfigIndex Integer32, pduCircuitBreakerConfigCount Integer32, pduCircuitBreakerName DisplayString, pduCircuitBreakerConfigOverloadRestriction INTEGER, pduCircuitBreakerConfigLowerCriticalThreshold Unsigned32, pduCircuitBreakerConfigLowerWarningThreshold Unsigned32, pduCircuitBreakerConfigUpperCriticalThreshold Unsigned32, pduCircuitBreakerConfigUpperWarningThreshold Unsigned32, pduCircuitBreakerConfigAlarmResetThreshold Unsigned32, pduCircuitBreakerConfigAlarmStateChangeDelay Unsigned32, pduCircuitBreakerConfigEnabledThresholds BITS } pduCircuitBreakerConfigIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU Circuit Breaker configuration table entry" ::= { pduCircuitBreakerConfigEntry 1 } pduCircuitBreakerConfigCount OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of circuit breakers on the PDU" ::= { pduCircuitBreakerConfigEntry 2 } pduCircuitBreakerName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The label of the circuit breaker" ::= { pduCircuitBreakerConfigEntry 3 } pduCircuitBreakerConfigOverloadRestriction OBJECT-TYPE SYNTAX INTEGER { alwaysAllowTurnOn (1), restrictOnUpperWarning (2), restrictOnUpperCritical (3), notSupported (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This OID controls the behavior of a Switched PDU Circuit Breaker when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding Circuit Breaker to turn on. Setting this OID to restrictOnUpperWarning (2) will not allow outlets on the corresponding Circuit Breaker to turn on if the pduCircuitBreakerConfigUpperWarningThreshold OID is exceeded. Setting this OID to restrictOnUpperCritical (3) will not allow outlets on the corresponding Circuit Breaker to turn on if the pduCircuitBreakerConfigUpperCriticalThreshold OID is exceeded. Models that do not support this feature will respond to this OID with a value of notSupported (4). Attempts to set this OID in these models will fail. " ::= { pduCircuitBreakerConfigEntry 4 } pduCircuitBreakerConfigLowerCriticalThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined lower critical circuit breaker current alarm threshold in hundredths of Amps(A)." ::= { pduCircuitBreakerConfigEntry 5 } pduCircuitBreakerConfigLowerWarningThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined lower non-critical (warning) circuit breaker current alarm threshold in hundredths of Amps(A)." ::= { pduCircuitBreakerConfigEntry 6 } pduCircuitBreakerConfigUpperCriticalThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined upper critical circuit breaker current alarm threshold in hundredths of Amps(A)." ::= { pduCircuitBreakerConfigEntry 7 } pduCircuitBreakerConfigUpperWarningThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined upper non-critical (warning) circuit breaker current alarm threshold in hundredths of Amps(A)." ::= { pduCircuitBreakerConfigEntry 8 } pduCircuitBreakerConfigAlarmResetThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The hysteresis used for deassertions in hundredths of Amps(A)." ::= { pduCircuitBreakerConfigEntry 9 } pduCircuitBreakerConfigAlarmStateChangeDelay OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The delay measured in samples before a state is asserted. If the value is zero, then the state is asserted as soon as it is detected; if it is non-zero, say n, then the assertion condition must exist for n+1 consecutive samples before the corresponding assertion event is reported." ::= { pduCircuitBreakerConfigEntry 10 } pduCircuitBreakerConfigEnabledThresholds OBJECT-TYPE SYNTAX BITS { lowerCritical (0), lowerWarning (1), upperWarning (2), upperCritical (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "A bit string indicating which alarm thresholds are enabled." ::= { pduCircuitBreakerConfigEntry 11 } pduCircuitBreakerPropertiesTable OBJECT-TYPE SYNTAX SEQUENCE OF PduCircuitBreakerPropertiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU circuit breaker properties" ::= { pduCircuitBreaker 3 } pduCircuitBreakerPropertiesEntry OBJECT-TYPE SYNTAX PduCircuitBreakerPropertiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A circuit breaker properties entry containing objects for a particular circuit breaker." INDEX { pduUnitPropertiesIndex, pduCircuitBreakerPropertiesIndex } ::= { pduCircuitBreakerPropertiesTable 1 } PduCircuitBreakerPropertiesEntry ::= SEQUENCE { pduCircuitBreakerPropertiesIndex Integer32, pduCircuitBreakerPropertiesCount Integer32, pduCircuitBreakerPropertiesInputLayout INTEGER, pduCircuitBreakerPropertiesCurrentRating Integer32 } pduCircuitBreakerPropertiesIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU Circuit Breaker properties table entry" ::= { pduCircuitBreakerPropertiesEntry 1 } pduCircuitBreakerPropertiesCount OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Circuit Breakers" ::= { pduCircuitBreakerPropertiesEntry 2 } pduCircuitBreakerPropertiesInputLayout OBJECT-TYPE SYNTAX INTEGER { seqPhase1ToNeutral (1), seqPhase2ToNeutral (2), seqPhase3ToNeutral (3), seqPhase1ToPhase2 (4), seqPhase2ToPhase3 (5), seqPhase3ToPhase1 (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This OID describes the outlet phase connections on the referenced bank as follows: seqPhase1ToNeutral(1) indicates that outlets attached to circuit breaker are connected from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicates that outlets attached to circuit breaker are connected from Phase 2 to Neutral. seqPhase3ToNeutral(3) indicates that outlets attached to circuit breaker are connected from Phase 3 to Neutral. seqPhase1ToPhase2(4) indicates that outlets attached to circuit breaker are connected from Phase 1 to Phase2. seqPhase2ToPhase3(5) indicates that outlets attached to circuit breaker are connected from Phase 2 to Phase3. seqPhase3ToPhase1(6) indicates that outlets attached to circuit breaker are connected from Phase 3 to Phase1. " ::= { pduCircuitBreakerPropertiesEntry 3 } pduCircuitBreakerPropertiesCurrentRating OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Circuit Breakers" ::= { pduCircuitBreakerPropertiesEntry 4 } pduCircuitBreakerStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF PduCircuitBreakerStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU circuit breaker status data" ::= { pduCircuitBreaker 4 } pduCircuitBreakerStatusEntry OBJECT-TYPE SYNTAX PduCircuitBreakerStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A circuit breaker status entry containing objects for a particular circuit breaker." INDEX { pduUnitStatusIndex, pduCircuitBreakerStatusIndex } ::= { pduCircuitBreakerStatusTable 1 } PduCircuitBreakerStatusEntry ::= SEQUENCE { pduCircuitBreakerStatusIndex Integer32, pduCircuitBreakerStatusCount Integer32, pduCircuitBreakerLabel DisplayString, pduCircuitBreakerStatusLoadState INTEGER, pduCircuitBreakerStatusCurrent Integer32 } pduCircuitBreakerStatusIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU Circuit Breaker status table entry" ::= { pduCircuitBreakerStatusEntry 1 } pduCircuitBreakerStatusCount OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Circuit Breakers" ::= { pduCircuitBreakerStatusEntry 2 } pduCircuitBreakerLabel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The label on the PDU identifying the circuit breaker" ::= { pduCircuitBreakerStatusEntry 3 } pduCircuitBreakerStatusLoadState OBJECT-TYPE SYNTAX INTEGER { upperCritical (1), upperWarning (2), lowerWarning (3), lowerCritical (4), normal (5), off (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the present load status of the PDU Circuit Breaker being queried" ::= { pduCircuitBreakerStatusEntry 4 } pduCircuitBreakerStatusCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the current draw, in hundredths of Amps(A), of the load on the PDU Circuit Breaker being queried." ::= { pduCircuitBreakerStatusEntry 5 } -- Start pduOutlet pduOutletSwitchedTableSize OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PDU Outlets" ::= { pduOutlet 1 } pduOutletSwitchedConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF PduOutletSwitchedConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU Switched Outlet configuration data" ::= { pduOutlet 2 } pduOutletSwitchedConfigEntry OBJECT-TYPE SYNTAX PduOutletSwitchedConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An outlet configuration entry containing objects for a particular outlet." INDEX { pduUnitConfigIndex, pduOutletSwitchedConfigIndex } ::= { pduOutletSwitchedConfigTable 1 } PduOutletSwitchedConfigEntry ::= SEQUENCE { pduOutletSwitchedConfigIndex Integer32, pduOutletSwitchedName DisplayString, pduOutletSwitchedStateOnStartup INTEGER, pduOutletSwitchedConfigPowerOnTime Integer32, pduOutletSwitchedConfigPowerOffTime Integer32, pduOutletSwitchedConfigRebootDuration Integer32 } pduOutletSwitchedConfigIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU Switched Outlet configuration table entry" ::= { pduOutletSwitchedConfigEntry 1 } pduOutletSwitchedName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The user-defined name for the Switched Outlet" ::= { pduOutletSwitchedConfigEntry 2 } pduOutletSwitchedStateOnStartup OBJECT-TYPE SYNTAX INTEGER { off (0), on (1), lastKnownState (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The outlet state on device startup; overrides the global value pduUnitConfigGlobalOutletStateOnStartup." ::= { pduOutletSwitchedConfigEntry 3 } pduOutletSwitchedConfigPowerOnTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The amount of delay, in seconds, between when power is provided to outlets the outlet and when this outlet starts providing power" ::= { pduOutletSwitchedConfigEntry 4 } pduOutletSwitchedConfigPowerOffTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The amount of time, in seconds, this outlet will delay powering off" ::= { pduOutletSwitchedConfigEntry 5 } pduOutletSwitchedConfigRebootDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The amount of time, in seconds, this outlet will remain in powered off state before returning to power on state during a reboot action." ::= { pduOutletSwitchedConfigEntry 6 } pduOutletSwitchedPropertiesTable OBJECT-TYPE SYNTAX SEQUENCE OF PduOutletSwitchedPropertiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU Switched Outlet properties" ::= { pduOutlet 3 } pduOutletSwitchedPropertiesEntry OBJECT-TYPE SYNTAX PduOutletSwitchedPropertiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An outlet properties entry containing objects for a particular outlet." INDEX { pduUnitPropertiesIndex, pduOutletSwitchedPropertiesIndex } ::= { pduOutletSwitchedPropertiesTable 1 } PduOutletSwitchedPropertiesEntry ::= SEQUENCE { pduOutletSwitchedPropertiesIndex Integer32, pduOutletSwitchedPropertiesNumber Integer32, pduOutletSwitchedPropertiesName DisplayString, pduOutletSwitchedPropertiesInputPhaseLayout INTEGER, pduOutletSwitchedPropertiesCircuitBreaker Integer32, pduOutletSwitchedPropertiesCurrentRating Integer32 } pduOutletSwitchedPropertiesIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU Switched Outlet properties table entry" ::= { pduOutletSwitchedPropertiesEntry 1 } pduOutletSwitchedPropertiesNumber OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The numeric Switched Outlet ID" ::= { pduOutletSwitchedPropertiesEntry 2 } pduOutletSwitchedPropertiesName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined switched outlet ID string" ::= { pduOutletSwitchedPropertiesEntry 3 } pduOutletSwitchedPropertiesInputPhaseLayout OBJECT-TYPE SYNTAX INTEGER { seqPhase1ToNeutral (1), seqPhase2ToNeutral (2), seqPhase3ToNeutral (3), seqPhase1ToPhase2 (4), seqPhase2ToPhase3 (5), seqPhase3ToPhase1 (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This OID describes the outlet phase connections on the referenced bank as follows: seqPhase1ToNeutral(1) indicates that outlets attached to Switched Outlet are connected from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicates that outlets attached to Switched Outlet are connected from Phase 2 to Neutral. seqPhase3ToNeutral(3) indicates that outlets attached to Switched Outlet are connected from Phase 3 to Neutral. seqPhase1ToPhase2(4) indicates that outlets attached to Switched Outlet are connected from Phase 1 to Phase2. seqPhase2ToPhase3(5) indicates that outlets attached to Switched Outlet are connected from Phase 2 to Phase3. seqPhase3ToPhase1(6) indicates that outlets attached to Switched Outlet are connected from Phase 3 to Phase1. " ::= { pduOutletSwitchedPropertiesEntry 4 } pduOutletSwitchedPropertiesCircuitBreaker OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The numeric Circuit Breaker ID" ::= { pduOutletSwitchedPropertiesEntry 5 } pduOutletSwitchedPropertiesCurrentRating OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The current rating of outlet in hundreths of ampere" ::= { pduOutletSwitchedPropertiesEntry 6 } pduOutletSwitchedStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF PduOutletSwitchedStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU Switched Outlet status data" ::= { pduOutlet 4 } pduOutletSwitchedStatusEntry OBJECT-TYPE SYNTAX PduOutletSwitchedStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Status data from the PDU Switched Outlet being queried" INDEX { pduUnitStatusIndex, pduOutletSwitchedStatusIndex } ::= { pduOutletSwitchedStatusTable 1 } PduOutletSwitchedStatusEntry ::= SEQUENCE { pduOutletSwitchedStatusIndex Integer32, pduOutletSwitchedStatusNumber Integer32, pduOutletSwitchedStatusName DisplayString, pduOutletSwitchedStatusState INTEGER } pduOutletSwitchedStatusIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU Switched Outlet status table entry" ::= { pduOutletSwitchedStatusEntry 1 } pduOutletSwitchedStatusNumber OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The numeric Switched Outlet ID" ::= { pduOutletSwitchedStatusEntry 2 } pduOutletSwitchedStatusName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined switched outlet ID string" ::= { pduOutletSwitchedStatusEntry 3 } pduOutletSwitchedStatusState OBJECT-TYPE SYNTAX INTEGER { off (0), on (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the present switch state of the PDU switched outlet being queried" ::= { pduOutletSwitchedStatusEntry 4 } pduOutletSwitchedControlTable OBJECT-TYPE SYNTAX SEQUENCE OF PduOutletSwitchedControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU Switched Outlet status data" ::= { pduOutlet 5 } pduOutletSwitchedControlEntry OBJECT-TYPE SYNTAX PduOutletSwitchedControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Status data from the PDU Switched Outlet being queried" INDEX { pduUnitConfigIndex, pduOutletSwitchedControlIndex } ::= { pduOutletSwitchedControlTable 1 } PduOutletSwitchedControlEntry ::= SEQUENCE { pduOutletSwitchedControlIndex Integer32, pduOutletSwitchedControlNumber Integer32, pduOutletSwitchedControlName DisplayString, pduOutletSwitchedControlCommand INTEGER } pduOutletSwitchedControlIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index to the PDU switched outlet control data table entry" ::= { pduOutletSwitchedControlEntry 1 } pduOutletSwitchedControlNumber OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The numeric Switched Outlet ID" ::= { pduOutletSwitchedControlEntry 2 } pduOutletSwitchedControlName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined switched outlet ID string" ::= { pduOutletSwitchedControlEntry 3 } pduOutletSwitchedControlCommand OBJECT-TYPE SYNTAX INTEGER { immediateOff (1), immediateOn (2), delayedOff (3), delayedOn (4), immediateReboot (5), delayedReboot (6), outletUnknown (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Getting this variable will return the outlet state. If the outlet is on, the immediateOn (2) value will be returned. If the outlet is off, the immediateOff (1) value will be returned. If the state of the outlet cannot be determined, the outletUnknown (7) value will be returned. If the outletUnknown condition should occur, all devices powered by the PDU should be shut down. The PDU's power should then be cycled to clear this condition. Setting this variable to immediateOn (2) will immediately turn the outlet on. Setting this variable to immediateOff (1) will immediately turn the outlet off. Setting this variable to immediateReboot (5) will cause the Switched PDU to perform an immediateOff command, wait the pduOutletSwitchedConfigRebootDuration OID time, and then perform an immediateOn command. Setting this variable to delayedOn (4) will turn the outlet on after the pduOutletSwitchedConfigPowerOnTime OID time has elapsed. Setting this variable to delayedOff (3) will turn the outlet off after the pduOutletSwitchedConfigPowerOffTime OID time has elapsed. Setting this variable to delayedReboot (6) will cause the Switched PDU to perform a delayedOff command, wait the pduOutletSwitchedConfigRebootDuration OID time, and then perform a delayedOn command." ::= { pduOutletSwitchedControlEntry 4 } pduOutletMeteredTableSize OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PDU Outlets" ::= { pduOutlet 6 } pduOutletMeteredConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF PduOutletMeteredConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU Metered Outlet configuration data" ::= { pduOutlet 7 } pduOutletMeteredConfigEntry OBJECT-TYPE SYNTAX PduOutletMeteredConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An outlet configuration entry containing objects for a particular outlet." INDEX { pduUnitConfigIndex, pduOutletMeteredConfigIndex } ::= { pduOutletMeteredConfigTable 1 } PduOutletMeteredConfigEntry ::= SEQUENCE { pduOutletMeteredConfigIndex Integer32, pduOutletMeteredName DisplayString, pduOutletMeteredConfigLowerCriticalThreshold Unsigned32, pduOutletMeteredConfigLowerWarningThreshold Unsigned32, pduOutletMeteredConfigUpperCriticalThreshold Unsigned32, pduOutletMeteredConfigUpperWarningThreshold Unsigned32, pduOutletMeteredConfigAlarmResetThreshold Unsigned32, pduOutletMeteredConfigAlarmStateChangeDelay Unsigned32, pduOutletMeteredConfigEnabledThresholds BITS } pduOutletMeteredConfigIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU Metered Outlet configuration table entry" ::= { pduOutletMeteredConfigEntry 1 } pduOutletMeteredName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The user-defined name for the Metered Outlet" ::= { pduOutletMeteredConfigEntry 2 } pduOutletMeteredConfigLowerCriticalThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined lower critical outlet active power alarm threshold in Watts(W)." ::= { pduOutletMeteredConfigEntry 3 } pduOutletMeteredConfigLowerWarningThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined lower non-critical (warning) outlet active power alarm threshold in Watts(W)." ::= { pduOutletMeteredConfigEntry 4 } pduOutletMeteredConfigUpperCriticalThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined upper critical outlet active power alarm threshold in Watts(W)." ::= { pduOutletMeteredConfigEntry 5 } pduOutletMeteredConfigUpperWarningThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined upper non-critical (warning) outlet active power alarm threshold in Watts(W)." ::= { pduOutletMeteredConfigEntry 6 } pduOutletMeteredConfigAlarmResetThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The hysteresis used for deassertions in Watts(W)." ::= { pduOutletMeteredConfigEntry 7 } pduOutletMeteredConfigAlarmStateChangeDelay OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The delay measured in samples before a state is asserted. If the value is zero, then the state is asserted as soon as it is detected; if it is non-zero, say n, then the assertion condition must exist for n+1 consecutive samples before the corresponding assertion event is reported." ::= { pduOutletMeteredConfigEntry 8 } pduOutletMeteredConfigEnabledThresholds OBJECT-TYPE SYNTAX BITS { lowerCritical (0), lowerWarning (1), upperWarning (2), upperCritical (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "A bit string indicating which alarm thresholds are enabled." ::= { pduOutletMeteredConfigEntry 9 } pduOutletMeteredPropertiesTable OBJECT-TYPE SYNTAX SEQUENCE OF PduOutletMeteredPropertiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU Metered Outlet properties" ::= { pduOutlet 8 } pduOutletMeteredPropertiesEntry OBJECT-TYPE SYNTAX PduOutletMeteredPropertiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration data from the PDU Metered Outlet being queried" INDEX { pduUnitPropertiesIndex, pduOutletMeteredPropertiesIndex } ::= { pduOutletMeteredPropertiesTable 1 } PduOutletMeteredPropertiesEntry ::= SEQUENCE { pduOutletMeteredPropertiesIndex Integer32, pduOutletMeteredPropertiesNumber Integer32, pduOutletMeteredPropertiesName DisplayString, pduOutletMeteredPropertiesInputPhaseLayout INTEGER, pduOutletMeteredPropertiesCircuitBreaker Integer32, pduOutletMeteredPropertiesPowerRating Integer32, pduOutletMeteredPropertiesCurrentRating Integer32 } pduOutletMeteredPropertiesIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU Metered Outlet properties table entry" ::= { pduOutletMeteredPropertiesEntry 1 } pduOutletMeteredPropertiesNumber OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The numeric Metered Outlet ID" ::= { pduOutletMeteredPropertiesEntry 2 } pduOutletMeteredPropertiesName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined Metered outlet ID string" ::= { pduOutletMeteredPropertiesEntry 3 } pduOutletMeteredPropertiesInputPhaseLayout OBJECT-TYPE SYNTAX INTEGER { seqPhase1ToNeutral (1), seqPhase2ToNeutral (2), seqPhase3ToNeutral (3), seqPhase1ToPhase2 (4), seqPhase2ToPhase3 (5), seqPhase3ToPhase1 (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This OID describes the outlet phase connections on the referenced bank as follows: seqPhase1ToNeutral(1) indicates that outlets attached to Metered Outlet are connected from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicates that outlets attached to Metered Outlet are connected from Phase 2 to Neutral. seqPhase3ToNeutral(3) indicates that outlets attached to Metered Outlet are connected from Phase 3 to Neutral. seqPhase1ToPhase2(4) indicates that outlets attached to Metered Outlet are connected from Phase 1 to Phase2. seqPhase2ToPhase3(5) indicates that outlets attached to Metered Outlet are connected from Phase 2 to Phase3. seqPhase3ToPhase1(6) indicates that outlets attached to Metered Outlet are connected from Phase 3 to Phase1. " ::= { pduOutletMeteredPropertiesEntry 4 } pduOutletMeteredPropertiesCircuitBreaker OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The numeric Circuit Breaker ID" ::= { pduOutletMeteredPropertiesEntry 5 } pduOutletMeteredPropertiesPowerRating OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum power rating of the PDU metered outlet" ::= { pduOutletMeteredPropertiesEntry 6 } pduOutletMeteredPropertiesCurrentRating OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Metered outlet current rating in hundreths of ampere" ::= { pduOutletMeteredPropertiesEntry 7 } pduOutletMeteredStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF PduOutletMeteredStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU Metered Outlet status data" ::= { pduOutlet 9 } pduOutletMeteredStatusEntry OBJECT-TYPE SYNTAX PduOutletMeteredStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Status data from the PDU Metered Outlet being queried" INDEX { pduUnitStatusIndex, pduOutletMeteredStatusIndex } ::= { pduOutletMeteredStatusTable 1 } PduOutletMeteredStatusEntry ::= SEQUENCE { pduOutletMeteredStatusIndex Integer32, pduOutletMeteredStatusNumber Integer32, pduOutletMeteredStatusName DisplayString, pduOutletMeteredStatusLoadState INTEGER, pduOutletMeteredStatusCurrent Integer32, pduOutletMeteredStatusActivePower Integer32, pduOutletMeteredStatusPowerFactor Integer32, pduOutletMeteredStatusPeakPower Integer32, pduOutletMeteredStatusPeakPowerTimeStamp DisplayString, pduOutletMeteredStatusPeakPowerStartTime DisplayString, pduOutletMeteredStatusResettableEnergy Integer32 } pduOutletMeteredStatusIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU Metered Outlet status table entry" ::= { pduOutletMeteredStatusEntry 1 } pduOutletMeteredStatusNumber OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The numeric Metered Outlet ID" ::= { pduOutletMeteredStatusEntry 2 } pduOutletMeteredStatusName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined Metered outlet ID string" ::= { pduOutletMeteredStatusEntry 3 } pduOutletMeteredStatusLoadState OBJECT-TYPE SYNTAX INTEGER { upperCritical (1), upperWarning (2), lowerWarning (3), lowerCritical (4), normal (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the present load status of the PDU metered outlet being queried." ::= { pduOutletMeteredStatusEntry 4 } pduOutletMeteredStatusCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the current draw, in hundredths of Amps(A), of the load on the PDU outlet being queried." ::= { pduOutletMeteredStatusEntry 5 } pduOutletMeteredStatusActivePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the power draw, in Watts(W), of the load on the PDU outlet being queried." ::= { pduOutletMeteredStatusEntry 6 } pduOutletMeteredStatusPowerFactor OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the ratio of active to apparent power of the PDU Outlet being queried" ::= { pduOutletMeteredStatusEntry 7 } pduOutletMeteredStatusPeakPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Returns peak power consumption, in Watts(W), of the Rack PDU outlet being queried." ::= { pduOutletMeteredStatusEntry 8 } pduOutletMeteredStatusPeakPowerTimeStamp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the date and time that this metered outlet's peak power consumption occurred" ::= { pduOutletMeteredStatusEntry 9 } pduOutletMeteredStatusPeakPowerStartTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the start date and time that this metered outlet began recording peak power observations" ::= { pduOutletMeteredStatusEntry 10 } pduOutletMeteredStatusResettableEnergy OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A user resettable energy meter measuring outlet load energy consumption in tenths of Kilowatt-Hours(kWh)." ::= { pduOutletMeteredStatusEntry 11 } -- Start pduExternalSensor pduExternalSensorTableSize OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of External Sensors" ::= { pduExternalSensor 1 } pduExternalSensorNamePlateTable OBJECT-TYPE SYNTAX SEQUENCE OF PduExternalSensorNamePlateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU ExternalSensorNamePlate data" ::= { pduExternalSensor 2 } pduExternalSensorNamePlateEntry OBJECT-TYPE SYNTAX PduExternalSensorNamePlateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "External Sensor Name Plate data from the external sensor being queried. The number of entries equals the value of pduExternalSensorNamePlateTableSize." INDEX { pduNamePlateIndex, pduExternalSensorNamePlateIndex } ::= { pduExternalSensorNamePlateTable 1 } PduExternalSensorNamePlateEntry ::= SEQUENCE { pduExternalSensorNamePlateIndex Integer32, pduExternalSensorNamePlateName DisplayString, pduExternalSensorNamePlateDescription DisplayString, pduExternalSensorNamePlateLocation DisplayString, pduExternalSensorNamePlateSerialNumber DisplayString, pduExternalSensorNamePlateType INTEGER, pduExternalSensorNamePlateUnits INTEGER, pduExternalSensorNamePlateIdentifier Integer32 } pduExternalSensorNamePlateIndex OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU External Sensor status table entry" ::= { pduExternalSensorNamePlateEntry 1 } pduExternalSensorNamePlateName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A user-defined string identifying the external sensor" ::= { pduExternalSensorNamePlateEntry 2 } pduExternalSensorNamePlateDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A user-defined description of the external sensor" ::= { pduExternalSensorNamePlateEntry 3 } pduExternalSensorNamePlateLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A user-defined string identifying the location of the PDU" ::= { pduExternalSensorNamePlateEntry 4 } pduExternalSensorNamePlateSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number of the external sensor being queried" ::= { pduExternalSensorNamePlateEntry 5 } pduExternalSensorNamePlateType OBJECT-TYPE SYNTAX INTEGER { temperature (1), humidity (2), doorSwitch (3), dryContact (4), spotFluid (5), ropeFluid (6), smoke (7), beacon (8), airVelocity (9), modbusAdapter (17), hidAdapter (18) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of external sensor." ::= { pduExternalSensorNamePlateEntry 6 } pduExternalSensorNamePlateUnits OBJECT-TYPE SYNTAX INTEGER { logic (0), degreeC (1), degreeF (2), percent (3), mps (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The base units the external sensor is measured in. This parameter does not apply to onOff, trip, vibration, waterDetection, smokeDetection sensors. " ::= { pduExternalSensorNamePlateEntry 7 } pduExternalSensorNamePlateIdentifier OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique identifier of the external sensor." ::= { pduExternalSensorNamePlateEntry 8 } pduExternalSensorConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF PduExternalSensorConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU External Sensor configuration data" ::= { pduExternalSensor 3 } pduExternalSensorConfigEntry OBJECT-TYPE SYNTAX PduExternalSensorConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration data from the PDU External Sensor being queried" INDEX { pduUnitConfigIndex, pduExternalSensorConfigIndex } ::= { pduExternalSensorConfigTable 1 } PduExternalSensorConfigEntry ::= SEQUENCE { pduExternalSensorConfigIndex Integer32, pduExternalSensorConfigLowerCriticalThreshold Unsigned32, pduExternalSensorConfigLowerWarningThreshold Unsigned32, pduExternalSensorConfigUpperCriticalThreshold Unsigned32, pduExternalSensorConfigUpperWarningThreshold Unsigned32, pduExternalSensorConfigEnabledThresholds BITS, pduExternalSensorConfigAlarmState INTEGER } pduExternalSensorConfigIndex OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU External Sensor configuration table entry" ::= { pduExternalSensorConfigEntry 1 } pduExternalSensorConfigLowerCriticalThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined lower critical alarm threshold in pduExternalSensorNamePlateUnits." ::= { pduExternalSensorConfigEntry 2 } pduExternalSensorConfigLowerWarningThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined lower non-critical (warning) alarm threshold in pduExternalSensorNamePlateUnits." ::= { pduExternalSensorConfigEntry 3 } pduExternalSensorConfigUpperCriticalThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined upper critical alarm threshold in pduExternalSensorNamePlateUnits." ::= { pduExternalSensorConfigEntry 4 } pduExternalSensorConfigUpperWarningThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "User-defined upper non-critical (warning) alarm threshold in pduExternalSensorNamePlateUnits." ::= { pduExternalSensorConfigEntry 5 } pduExternalSensorConfigEnabledThresholds OBJECT-TYPE SYNTAX BITS { lowerCritical (0), lowerWarning (1), upperWarning (2), upperCritical (3), binarySensorAlarm (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "A bit string indicating which alarm thresholds are enabled." ::= { pduExternalSensorConfigEntry 6 } pduExternalSensorConfigAlarmState OBJECT-TYPE SYNTAX INTEGER { on (1), off (0) } MAX-ACCESS read-write STATUS current DESCRIPTION "User defined alarm state of external sensor" ::= { pduExternalSensorConfigEntry 7 } pduExternalSensorStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF PduExternalSensorStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PDU External Sensor status data" ::= { pduExternalSensor 4 } pduExternalSensorStatusEntry OBJECT-TYPE SYNTAX PduExternalSensorStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Status data from the PDU External Sensor being queried" INDEX { pduUnitStatusIndex, pduExternalSensorStatusIndex } ::= { pduExternalSensorStatusTable 1 } PduExternalSensorStatusEntry ::= SEQUENCE { pduExternalSensorStatusIndex Integer32, pduExternalSensorStatusName DisplayString, pduExternalSensorStatusCommStatus INTEGER, pduExternalSensorStatusState INTEGER, pduExternalSensorStatusValue Integer32, pduExternalSensorStatusTimeStamp DisplayString, pduExternalSensorStatusHighPrecisionValue Integer32 } pduExternalSensorStatusIndex OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU External Sensor status table entry" ::= { pduExternalSensorStatusEntry 1 } pduExternalSensorStatusName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name for the External Sensor" ::= { pduExternalSensorStatusEntry 2 } pduExternalSensorStatusCommStatus OBJECT-TYPE SYNTAX INTEGER { notInstalled (1), commsOk (2), commsLost (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The communications status of the sensor" ::= { pduExternalSensorStatusEntry 3 } pduExternalSensorStatusState OBJECT-TYPE SYNTAX INTEGER { notPresent (0), alarmed (1), normal (2), belowLowerCritical (3), belowLowerWarning (4), aboveUpperWarning (5), aboveUpperCritical (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This OID reports the current state of the sensor. A notPresent (0) response indicates that no sensor is attached. An alarmed (1) response indicates that the sensor is present and its measured reading indicates alarmed. A normal (2) response indicates that the sensor is present and its measured reading lies within all thresholds. A belowLowerCritical (3) response indicates that the sensor is present and its measured reading lies below the lower critical threshold. A belowLowerWarning (4) response indicates that the sensor is present and its measured reading lies below the lower warning threshold. An aboveUpperWarning (5) response indicates that the sensor is present and its measured reading lies above the upper warning threshold. An aboveUpperCritical (6) response indicates that the sensor is present and its measured reading lies above the upper critical threshold." ::= { pduExternalSensorStatusEntry 4 } pduExternalSensorStatusValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor reading in pduExternalSensorConfigUnits value." ::= { pduExternalSensorStatusEntry 5 } pduExternalSensorStatusTimeStamp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The sensor reading timestamp." ::= { pduExternalSensorStatusEntry 6 } pduExternalSensorStatusHighPrecisionValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature sensor reading in tenths of pduExternalSensorConfigUnits value. This OID is applied to temperature sensor only" ::= { pduExternalSensorStatusEntry 7 } -- Smart Cabinet pduUnitSmartCabinetTableSize OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of Smart Cabinet Configuration " ::= { pduSmartCabinet 1 } pduUnitSmartCabinetTable OBJECT-TYPE SYNTAX SEQUENCE OF PduUnitSmartCabinetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of Smart Cabinet information" ::= { pduSmartCabinet 2 } pduUnitSmartCabinetEntry OBJECT-TYPE SYNTAX PduUnitSmartCabinetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information of Smart Cabinet" INDEX { pduUnitSmartCabinetIndex } ::= { pduUnitSmartCabinetTable 1 } PduUnitSmartCabinetEntry ::= SEQUENCE { pduUnitSmartCabinetIndex Integer32, pduUnitSmartCabinetCardUserName DisplayString, pduUnitSmartCabinetCardID Integer32, pduUnitSmartCabinetTimestamp DisplayString, pduUnitSmartCabinetDoor INTEGER } pduUnitSmartCabinetIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU Smart Cabinet table entry" ::= { pduUnitSmartCabinetEntry 1 } pduUnitSmartCabinetCardUserName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "User name of ID card" ::= { pduUnitSmartCabinetEntry 2 } pduUnitSmartCabinetCardID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Card ID." ::= { pduUnitSmartCabinetEntry 3 } pduUnitSmartCabinetTimestamp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the date and time of information update" ::= { pduUnitSmartCabinetEntry 4 } pduUnitSmartCabinetDoor OBJECT-TYPE SYNTAX INTEGER { hotAisle (1), coldAisle (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Aisle of Smart Cabinet. " ::= { pduUnitSmartCabinetEntry 5 } pduUnitSmartCabinetControl OBJECT IDENTIFIER ::= { pduSmartCabinet 3 } pduUnitSmartCabinetControlUserName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "User name of ID card" ::= { pduUnitSmartCabinetControl 1 } pduUnitSmartCabinetControlCardID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Card ID." ::= { pduUnitSmartCabinetControl 2 } pduUnitSmartCabinetControlTimestamp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the date and time of information update" ::= { pduUnitSmartCabinetControl 3 } pduUnitSmartCabinetControlDoor OBJECT-TYPE SYNTAX INTEGER { hotAisle (1), coldAisle (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Aisle of Smart Cabinet. " ::= { pduUnitSmartCabinetControl 4 } pduUnitSmartCabinetCardIDEdit OBJECT-TYPE SYNTAX INTEGER { grant (0), remove (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Smart Cabinet edit CardID " ::= { pduUnitSmartCabinetControl 5 } pduUnitSmartCabinetColdAisleLockStatus OBJECT-TYPE SYNTAX INTEGER { unlock (0), lock (1), notPresent (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Smart Cabinet ColdAisle lock state " ::= { pduUnitSmartCabinetControl 6 } pduUnitSmartCabinetHotAisleLockStatus OBJECT-TYPE SYNTAX INTEGER { unlock (0), lock (1), notPresent (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Smart Cabinet HotAisle lock state " ::= { pduUnitSmartCabinetControl 7 } pduUnitSmartCabinetLockStateTable OBJECT-TYPE SYNTAX SEQUENCE OF PduUnitSmartCabinetLockStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of Smart Cabinet aisle state control" ::= { pduSmartCabinet 4 } pduUnitSmartCabinetLockStateEntry OBJECT-TYPE SYNTAX PduUnitSmartCabinetLockStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information of Smart Cabinet Lock State" INDEX { pduUnitSmartCabinetLockStateIndex } ::= { pduUnitSmartCabinetLockStateTable 1 } PduUnitSmartCabinetLockStateEntry ::= SEQUENCE { pduUnitSmartCabinetLockStateIndex Integer32, pduUnitSmartCabinetColdAisleLockState INTEGER, pduUnitSmartCabinetHotAisleLockState INTEGER, pduUnitSmartCabinetColdAisleLockLabel DisplayString, pduUnitSmartCabinetHotAisleLockLabel DisplayString } pduUnitSmartCabinetLockStateIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the PDU Smart Cabinet table entry" ::= { pduUnitSmartCabinetLockStateEntry 1 } pduUnitSmartCabinetColdAisleLockState OBJECT-TYPE SYNTAX INTEGER { unlock (0), lock (1), notPresent (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Smart Cabinet ColdAisle lock state " ::= { pduUnitSmartCabinetLockStateEntry 2 } pduUnitSmartCabinetHotAisleLockState OBJECT-TYPE SYNTAX INTEGER { unlock (0), lock (1), notPresent (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Smart Cabinet HotAisle lock state " ::= { pduUnitSmartCabinetLockStateEntry 3 } pduUnitSmartCabinetColdAisleLockLabel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Label of cold aisle smartcabinet" ::= { pduUnitSmartCabinetLockStateEntry 4 } pduUnitSmartCabinetHotAisleLockLabel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Label of hot aisle smartcabinet" ::= { pduUnitSmartCabinetLockStateEntry 5 } -- Traps Information trapsInfo OBJECT IDENTIFIER ::= { pduTraps 1 } trapsInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF TrapsInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Trap Information entries. The number of entries are given by the value of pduUnitTableSize." ::= { trapsInfo 1 } trapsInfoEntry OBJECT-TYPE SYNTAX TrapsInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing objects used in traps" INDEX { trapsInfoIndex } ::= { trapsInfoTable 1 } TrapsInfoEntry ::= SEQUENCE { trapsInfoIndex Integer32, userName DisplayString, userUpdated DisplayString, firmwareVersion DisplayString, roleUpdated DisplayString, smtpRecipients DisplayString, smtpServer DisplayString } trapsInfoIndex OBJECT-TYPE SYNTAX Integer32 (1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of the traps table entry" ::= { trapsInfoEntry 1 } userName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The user currently logged in." ::= { trapsInfoEntry 2 } userUpdated OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The user added, deleted, or modified." ::= { trapsInfoEntry 3 } firmwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The version of Firmware." ::= { trapsInfoEntry 4 } roleUpdated OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The role added, deleted, or modified." ::= { trapsInfoEntry 5 } smtpRecipients OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Comma separated list of SMTP recipients" ::= { trapsInfoEntry 6 } smtpServer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address/host name of the SMTP server" ::= { trapsInfoEntry 7 } pduIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "A unique value for PDU. Its value ranges between 1 and the value of PDU count" ::= { trapsInfo 2 } externalSensorIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "A unique value for each sensor. Its value ranges between 1 and the value of external sensor count." ::= { trapsInfo 3 } serverPing OBJECT-TYPE SYNTAX INTEGER { pingEnable (1), pingDisable (2), serverReachable (3), serverNotReachable (4) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Whether server ping has been enabled or disabled and whether the server is reachable or not reachable" ::= { trapsInfo 4 } usbDevice OBJECT-TYPE SYNTAX INTEGER { connected (1), disconnected (2) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Whether a USB device has been connected or disconnected" ::= { trapsInfo 5 } errorDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Description of the Error" ::= { trapsInfo 6 } cascading OBJECT-TYPE SYNTAX INTEGER { connected (1), disconnected (2) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Whether a cascading member has been connected or disconnected" ::= { trapsInfo 7 } systemCommunication OBJECT-TYPE SYNTAX INTEGER { ok (1), lost (2) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Whether the Network management card has lost contact with cascading member." ::= { trapsInfo 8 } trapCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A number identifying the event for the trap that was sent. Mapped unique trap code per unique event to be used by ISEE's decoder ring." ::= { trapsInfo 9 } trapDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A string identifying the event for that last trap that was sent." ::= { trapsInfo 10 } trapCritical NOTIFICATION-TYPE OBJECTS { trapCode, trapDescription, sysDescr, pduNamePlateIPAddress} STATUS current DESCRIPTION "A critical alarm has occurred." ::= {pduTraps 1} trapWarning NOTIFICATION-TYPE OBJECTS { trapCode, trapDescription, sysDescr, pduNamePlateIPAddress} STATUS current DESCRIPTION "A warning alarm has occurred." ::= {pduTraps 2} trapInformation NOTIFICATION-TYPE OBJECTS { trapCode, trapDescription, sysDescr, pdug5IPv4Address } STATUS current DESCRIPTION "An informational alarm has occurred." ::= {pduTraps 3} trapCleared NOTIFICATION-TYPE OBJECTS { trapCode, trapDescription, sysDescr, pduNamePlateIPAddress} STATUS current DESCRIPTION "An alarm has cleared." ::= {pduTraps 4} trapTest NOTIFICATION-TYPE OBJECTS { trapCode, trapDescription, sysDescr, pduNamePlateIPAddress} STATUS current DESCRIPTION "Test trap sent to a trap receiver to check proper reception of traps" ::= {pduTraps 5} -- ======Ehandle Sensor Status========== pduEhandleTable OBJECT-TYPE SYNTAX SEQUENCE OF PduEhandleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of contact sensors. The number of entries are given by number of pdu and pduEhandleCount." ::= { pduEhandle 1 } pduEhandleEntry OBJECT-TYPE SYNTAX PduEhandleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry for a contact sensor" INDEX { pduEhandleIndex } ::= { pduEhandleTable 1 } PduEhandleEntry ::= SEQUENCE { pduEhandleIndex INTEGER, pduEhandleAisle INTEGER, pduEhandleHandleOperation INTEGER, pduEhandleFwVer DisplayString, pduEhandleMechanicalLock INTEGER, pduEhandleSerial DisplayString, pduEhandleHwVer DisplayString, pduEhandleAutoLockTime INTEGER, pduEhandleDoorOpenTime INTEGER, pduEhandleMaxDoorOpenTime INTEGER, pduEhandleUserPinLength INTEGER, pduEhandleUserPinMode INTEGER, pduEhandleAisleControl INTEGER } pduEhandleIndex OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the PDU HID table entry" ::= { pduEhandleEntry 1 } pduEhandleAisle OBJECT-TYPE SYNTAX INTEGER { hot(1), cold(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Aisle of HID handle. " ::= { pduEhandleEntry 2 } pduEhandleHandleOperation OBJECT-TYPE SYNTAX INTEGER { unlock(1), lock(2) } ACCESS read-write STATUS mandatory DESCRIPTION "HID handle control opterations " ::= { pduEhandleEntry 3 } pduEhandleFwVer OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The firmware revision level of the HID" ::= { pduEhandleEntry 4 } pduEhandleMechanicalLock OBJECT-TYPE SYNTAX INTEGER { unlock(1), lock(2) } ACCESS read-only STATUS mandatory DESCRIPTION "HID Mechanical opterations " ::= { pduEhandleEntry 5 } pduEhandleSerial OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Serial Number of the HID" ::= { pduEhandleEntry 6 } pduEhandleHwVer OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The hardware revision level of the HID" ::= { pduEhandleEntry 7 } pduEhandleAutoLockTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "HID Electronic Latch Autolock Time in seconds, Value ranges (0-999) " ::= { pduEhandleEntry 8 } pduEhandleDoorOpenTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "HID Door Open Time in seconds, Value ranges (0-999)" ::= { pduEhandleEntry 9 } pduEhandleMaxDoorOpenTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "HID Max Door Open Time in seconds, Value ranges (0-32400), critical alarm will be raised if door is left open past this time" ::= { pduEhandleEntry 10 } pduEhandleUserPinLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Rack Access User minimum PIN Length, value ranges(1-15)" ::= { pduEhandleEntry 11 } pduEhandleUserPinMode OBJECT-TYPE SYNTAX INTEGER { visible(1), hidden (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Rack Access User PIN mode setting" ::= { pduEhandleEntry 12 } pduEhandleAisleControl OBJECT-TYPE SYNTAX INTEGER { combined (1), standalone(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Rack Access Aisle Control setting, when set to standalone each aisle will controlled seprately, when set to combined opposite aisle can be controlled with authenticated control action on either aisle" ::= { pduEhandleEntry 13 } -- ======EHANDLE control table========== pduEhandleControlTable OBJECT-TYPE SYNTAX SEQUENCE OF PduEhandleControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of smartcard. The number of entries are given by number of pdu and pduEhandleCount." ::= { pduEhandle 2 } pduEhandleControlEntry OBJECT-TYPE SYNTAX PduEhandleControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The smart card table entry containing the usrname, cardid, cardaisle etc." INDEX { pduEhandleControlIndex } ::= { pduEhandleControlTable 1 } PduEhandleControlEntry ::= SEQUENCE { pduEhandleControlIndex INTEGER, pduEhandleControlUserName DisplayString, pduEhandleControlCardIdStr DisplayString, pduEhandleControlTimestamp DisplayString, pduEhandleControlCardAisle INTEGER, pduEhandleControlStartTime DisplayString, pduEhandleControlExpireTime DisplayString, pduEhandleControlTempUser INTEGER, pduEhandleControlPin DisplayString, } pduEhandleControlIndex OBJECT-TYPE SYNTAX INTEGER (1..200) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the PDU smartcard table entry" ::= { pduEhandleControlEntry 1 } pduEhandleControlUserName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User name of smartcard" ::= { pduEhandleControlEntry 2 } pduEhandleControlCardIdStr OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "smartcard ID." ::= { pduEhandleControlEntry 3 } pduEhandleControlTimestamp OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the date and time of accessing" ::= { pduEhandleControlEntry 4 } pduEhandleControlCardAisle OBJECT-TYPE SYNTAX INTEGER { hot(1), cold(2), both (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Aisle of authorized card" ::= { pduEhandleControlEntry 5 } pduEhandleControlStartTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the start date and time Rack access user is given access" ::= { pduEhandleControlEntry 6 } pduEhandleControlExpireTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the date and time when the access of user card will expire, To set expire time first set user as temporary user" ::= { pduEhandleControlEntry 7 } pduEhandleControlTempUser OBJECT-TYPE SYNTAX INTEGER { no(1), yes(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates if the card user has temporary access" ::= { pduEhandleControlEntry 8 } pduEhandleControlPin OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Rack acess control entry keypad PIN" ::= { pduEhandleControlEntry 9 } -- ++++ End of cPDU ++++ END