-- ============================================================ -- Description : -- -- Rainbow Notifications Management Information Base -- -- 06/06/2006 -- -- -- ============================================================ RAINBOW-NOTIFICATIONS-MIB DEFINITIONS ::= BEGIN IMPORTS rainbow, rbTrapSeqNumber,rbTrapSource,rbTrapSeverity,rbTrapCategory,rbTrapAdditionalInfo, rbChannelId,rbSuTxPower,rbLicenseId,rbSuMacAddr,rbSuSysName,rbTrapLedStatus,rbTrapIpAddress, rbTrapSetFailureReason FROM RAINBOW-MIB rbServiceIdx, rbServiceName, rbSubscriberIdx, rbSubscriberID FROM RAINBOW-SERVICES-MIB rbRadiusAuthServerAddress, rbRadiusAcctServerAddress FROM RAINBOW-RADIUS-MIB MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI; -- enterprises OBJECT IDENTIFIER ::= -- { iso org(3) dod(6) internet(1) private(4) 1 } -- alvarion OBJECT IDENTIFIER ::= { enterprises 12394 } -- products OBJECT IDENTIFIER ::= { alvarion 1 } -- rainbow OBJECT IDENTIFIER ::= { products 2 } rbNotifications MODULE-IDENTITY LAST-UPDATED "200606061500Z" ORGANIZATION "Alvarion Ltd." CONTACT-INFO "Alvarion Customer Service Postal: Alvarion Ltd. Barzel 21 Tel Aviv 69710 ISRAEL E-mail: CS_Coordinator@alvarion.com" DESCRIPTION "Rainbow notifications MIB Definitions" REVISION "200606061500Z" DESCRIPTION "Release 2.5" ::= { rainbow 0 } --======================================================================== -- General Traps --======================================================================== rbResetOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "This trap is sent when the device/card is going to perform reset. rbTrapSource = NPU/AU/SU rbTrapSeverity = Info rbTrapCategory = Equipment rbTrapAdditionalInfo = 1..2 for external/internal fault." ::= { rbNotifications 1 } rbDiagnosticsHwFaultOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo, rbTrapLedStatus } STATUS current DESCRIPTION "Device/card has detected hardware fault. rbTrapSource = NPU/AU/SU rbTrapSeverity = Major rbTrapCategory = Equipment rbTrapAdditionalInfo = 3..8,23..27." ::= { rbNotifications 2 } rbDiagnosticsHwFaultOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo, rbTrapLedStatus } STATUS current DESCRIPTION "Previously detected hardware fault is fixed. rbTrapSource = NPU/AU/SU rbTrapSeverity = Info rbTrapCategory = Equipment rbTrapAdditionalInfo = 3..8,23..27." ::= { rbNotifications 3 } rbMonitorAccessOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo, rbTrapIpAddress } STATUS current DESCRIPTION "Device is accessed via LCI or Telnet. rbTrapSource = NPU/SU rbTrapSeverity = Info, rbTrapCategory = Equipment, rbTrapAdditionalInfo = 140,141, rbTrapIpAddress " ::= { rbNotifications 4 } rbMonitorAccessOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo, rbTrapIpAddress } STATUS current DESCRIPTION "LCI or Telnet access was terminated rbTrapSource = NPU/SU rbTrapSeverity = Info, rbTrapCategory = Equipment, rbTrapAdditionalInfo = 140,141, rbTrapIpAddress " ::= { rbNotifications 5 } rbAuNetworkEntryStatus NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "AU Network Entry status changed rbTrapSource = AU rbTrapSeverity = Info, rbTrapCategory = Communication, rbTrapAdditionalInfo = 135-139 " ::= { rbNotifications 6 } rbModeConflictOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "AU/SU mode conflict was detected rbTrapSource = AU/SU rbTrapSeverity = Major, rbTrapCategory = Communication, rbTrapAdditionalInfo = 144 .. 149." ::= { rbNotifications 7 } rbModeConflictOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "AU/SU mode conflict terminated rbTrapSource = AU/SU rbTrapSeverity = Info, rbTrapCategory = Communication, rbTrapAdditionalInfo = 144." ::= { rbNotifications 8 } --======================================================================== -- Shelf Related Traps 21..40 --======================================================================== rbShelfCardExtractionOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "Card is extracted from the shelf. rbTrapSource = NPU/AU/PSU/PIU/ACU rbTrapSeverity = Info, rbTrapCategory = Equipment " ::= { rbNotifications 21 } rbShelfCardInsertionOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "Card is inserted in the shelf. rbTrapSource = NPU/AU/PSU/PIU/ACU rbTrapSeverity = Info, rbTrapCategory = Equipment" ::= { rbNotifications 22 } rbShelfPeripheralEquipmentFaultOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "Fault is detected in one of the Shelf Peripheral Equipment Units. rbTrapSource = PSU#/PIU#/ACU#/ACU-FAN#/AU rbTrapSeverity = Minor, rbTrapCategory = Equipment rbTrapAdditionalInfo = 53..55" ::= { rbNotifications 23 } rbShelfPeripherallEquipmentFaultOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "Previously detected fault in one of the shelf Peripheral Equipment Units is terminated. rbTrapSource = PSU#/PIU#/ACU#/AU rbTrapSeverity = Info, rbTrapCategory = Equipment rbTrapAdditionalInfo = 53..55" ::= { rbNotifications 24 } rbShelfEnvParamFaultOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "Fault is detected in the shelf environment parameter. rbTrapSource = NPU rbTrapSeverity = Info, rbTrapCategory = Equipment rbTrapAdditionalInfo = 73..76" ::= { rbNotifications 25 } rbShelfEnvParamFaultOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "Previously detected environment parameter fault is terminated. rbTrapSource = NPU rbTrapSeverity = Info, rbTrapCategory = Equipment rbTrapAdditionalInfo = 73..76" ::= { rbNotifications 26 } --======================================================================== -- NPU/MBST Related Traps 41 ..60 --======================================================================== rbConfigurationChanged NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "Configuration change was detected, rbTrapSource = NPU/AU/SU/RC/ODU/CHNL/SBSCR/SRVC rbTrapSeverity = Info, rbTrapCategory = Equipment rbTrapAdditionalInfo = 30..33." ::= { rbNotifications 41 } rbParameterSetFailure NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapSetFailureReason } STATUS current DESCRIPTION "Configuration change was detected, rbTrapSource = NPU/AU/SU rbTrapSeverity = Info, rbTrapCategory = Equipment rbTrapSetFailureReason." ::= { rbNotifications 42 } rbMbstLicense NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "License Grace Period expiration warning, rbTrapSource = MicroBST rbTrapSeverity = Info, rbTrapCategory = Proc, rbTrapAdditionalInfo = 184,185." ::= { rbNotifications 50 } rbMbstCPEQuantityExceed NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbSuMacAddr } STATUS current DESCRIPTION "Allowed quantity of CPEs exceeded in the actual Mbst, rbTrapSource = MicroBST rbTrapSeverity = Info, rbTrapCategory = Proc, rbSuMacAddr = Rejected SU Mac" ::= { rbNotifications 51 } rbLicenseFileLoadStatus NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "License File Load process status, rbTrapSource = NPU/MicroBST rbTrapSeverity = Info, rbTrapCategory = Proc, rbTrapAdditionalInfo = 187..191" ::= { rbNotifications 52 } --======================================================================== -- ODU Related Traps 61 .. 80 --======================================================================== rbOduCrcErrorOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbChannelId } STATUS obsolete DESCRIPTION "Obsolete from release 2.5 CRC error in the ODU table was detected, rbTrapSource = AU rbTrapSeverity = Warning, rbTrapCategory = Communication, rbChannelId = number of channel " ::= { rbNotifications 61 } rbOduCrcErrorOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbChannelId } STATUS obsolete DESCRIPTION "Obsolete from release 2.5 Previously detected CRC error in ODU table terminated, rbTrapSource = AU rbTrapSeverity = Info, rbTrapCategory = Communication, rbChannelId = number of channel " ::= { rbNotifications 62 } rbOduCommErrorOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbChannelId } STATUS current DESCRIPTION "Error in the communication with the ODU unit was detected, rbTrapSource = AU rbTrapSeverity = Minor, rbTrapCategory = Communication, rbChannelId = number of channel " ::= { rbNotifications 63 } rbOduCommErrorOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbChannelId } STATUS current DESCRIPTION "Previously detected ODU communication error terminated, rbTrapSource = AU, rbTrapSeverity = Info, rbTrapCategory = Communication, rbChannelId = number of channel " ::= { rbNotifications 64 } rbOduBandMissmatchOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbChannelId } STATUS current DESCRIPTION "Actual ODU Band does not match configured ODU Band, rbTrapSource = AU, rbTrapSeverity = Major, rbTrapCategory = Communication, rbChannelId = number of channel " ::= { rbNotifications 65 } rbOduBandMissmatchOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbChannelId } STATUS current DESCRIPTION "Previously detected ODU Band mismatch terminated, rbTrapSource = AU, rbTrapSeverity = Info, rbTrapCategory = Communication, rbChannelId = number of channel " ::= { rbNotifications 66 } rbOduPowerMismatch NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbChannelId } STATUS current DESCRIPTION "Actual ODU Max/Min Tx power does not match configured ODU Max/Min Tx power, rbTrapSource = AU, rbTrapSeverity = Info, rbTrapCategory = Communication, rbChannelId = number of channel " ::= { rbNotifications 67 } rbOduFailureOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbChannelId, rbTrapAdditionalInfo } STATUS current DESCRIPTION "ODU unit failure was detected, rbTrapSource = AU rbTrapSeverity = Major, rbTrapCategory = Communication, rbChannelId = number of channel, rbTrapAdditionalInfo = 225..228" ::= { rbNotifications 68 } rbOduFailureOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbChannelId } STATUS current DESCRIPTION "Previously detected ODU failure terminated, rbTrapSource = AU, rbTrapSeverity = Info, rbTrapCategory = Communication, rbChannelId = number of channel " ::= { rbNotifications 69 } --======================================================================== -- SU Related Traps 81 .. 100 --======================================================================== rbSuMaxTxPowerReached NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbSuTxPower } STATUS current DESCRIPTION "SU reached the maximum allowed output power, rbTrapSource = SU rbTrapSeverity = Info, rbTrapCategory = PROC " ::= { rbNotifications 81 } rbSuMinTxPowerReached NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbSuTxPower } STATUS current DESCRIPTION "SU reached the minimum allowed output power rbTrapSource = SU rbTrapSeverity = Info, rbTrapCategory = PROC " ::= { rbNotifications 82 } rbSuNetworkEntryStatus NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "Status of the SU's network entry. rbTrapSource = SU, rbTrapSeverity = Info, rbTrapCategory = PROC, rbTrapAdditionalInfo = 132-134" ::= { rbNotifications 83 } rbSuLicense NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo, rbLicenseId } STATUS current DESCRIPTION "License Grace Period expiration warning, rbTrapSource = SU rbTrapSeverity = Info, rbTrapCategory = Proc, rbTrapAdditionalInfo = 182-186, rbLicenseId = Type of License." ::= { rbNotifications 84 } rbSuDuplicateName NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbSuMacAddr, rbSuSysName, rbSuSysName } STATUS current DESCRIPTION "The SU Name is already in use by another SU. Services to the SU will be denied until another, unique name is configured for the SU. rbTrapSource = SU, rbTrapSeverity = Major, rbTrapCategory = PROC rbSuMacAddr = Mac of other SU with same name, rbSuSysName = previous name, rbSuSysName = new name" ::= { rbNotifications 85 } --======================================================================== -- Software Download Related Traps 101..108 --======================================================================== rbSwDownloadStart NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "Software download process is started. rbTrapSource = NPU/AU/SU rbTrapSeverity = Info, rbTrapCategory = PROC " ::= { rbNotifications 101 } rbSwDownloadEnd NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "Software download process is finished rbTrapSource = NPU/AU/SU rbTrapSeverity = Info, rbTrapCategory = PROC " ::= { rbNotifications 102 } rbSwDownloadError NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "Software download process error. rbTrapSource = NPU/AU/SU rbTrapSeverity = Minor, rbTrapCategory = PROC rbTrapAdditionalInfo =100..103" ::= { rbNotifications 103 } rbSwSwitchFailed NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "Software switch over failed. rbTrapSource = NPU/AU/SU rbTrapSeverity = Minor, rbTrapCategory = PROC, rbTrapAdditionalInfo = 104..105" ::= { rbNotifications 104 } rbSwSwitchSucceed NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "Software switch over succeeded , rbTrapSource = NPU/AU/SU rbTrapSeverity = Info, rbTrapCategory = PROC, rbTrapAdditionalInfo = " ::= { rbNotifications 105 } rbBERTestFinished NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "BER Test is finished , rbTrapSource = SU rbTrapSeverity = Info, rbTrapCategory = PROC " ::= { rbNotifications 106 } rbBERTestStarted NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "BER Test is started , rbTrapSource = SU rbTrapSeverity = Info, rbTrapCategory = PROC " ::= { rbNotifications 107 } rbSwFileConflict NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "AU configured SW file and AU HW mismatch, rbTrapSource = AU/SU rbTrapSeverity = Minor, rbTrapCategory = PROC " ::= { rbNotifications 108 } --======================================================================== -- Download Related Traps 109..110 --======================================================================== rbXMLDownloadResult NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "XML File Download status. rbTrapSource = NPU rbTrapSeverity = Info, rbTrapCategory = PROC, rbTrapAdditionalInfo = 220..224" ::= { rbNotifications 109 } rbFreqBandDownloadResult NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "Frequency Band File Download status. rbTrapSource = NPU rbTrapSeverity = Info, rbTrapCategory = PROC, rbTrapAdditionalInfo = 220..222,224" ::= { rbNotifications 110 } --======================================================================== -- Service Related Traps 111..115 --======================================================================== rbServiceDown NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbServiceIdx, rbSubscriberIdx, rbServiceName, rbSubscriberID } STATUS current DESCRIPTION "The Service is down or didn't start, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCategory = QoS" ::= { rbNotifications 111 } rbServiceUp NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbServiceIdx, rbSubscriberIdx, rbServiceName, rbSubscriberID } STATUS current DESCRIPTION "The Service is operational, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = QoS" ::= { rbNotifications 112 } rbServiceChanged NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo, rbServiceIdx, rbSubscriberIdx, rbServiceName, rbSubscriberID } STATUS current DESCRIPTION "The Service was modified, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = QoS, rbTrapAdditionalInfo = 119..122" ::= { rbNotifications 113 } rbServiceGeneralError NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo, rbServiceIdx, rbSubscriberIdx, rbServiceName, rbSubscriberID } STATUS current DESCRIPTION "Service error was detected, rbTrapSource = NPU, rbTrapSeverity = Minor, rbTrapCategory = QoS rbTrapAdditionalInfo =111..118." ::= { rbNotifications 114 } rbNetworkingError NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo } STATUS current DESCRIPTION "Loop was detected on SU Ethernet port, rbTrapSource = SU rbTrapSeverity = Info, rbTrapCategory = PROC, rbTrapAdditionalInfo = 10.. " ::= { rbNotifications 115 } --======================================================================== -- Radius Related Traps 117..127 --======================================================================== rbSwitchedAuthenticationServer NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "RADIUS Client switched to another Authentication Server, rbTrapSource = NPU rbTrapSeverity = Info, rbTrapCategory = COMM " ::= { rbNotifications 117 } rbSwitchedAccountingServer NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "RADIUS Client switched to another Accounting Server, rbTrapSource = NPU rbTrapSeverity = Info, rbTrapCategory = COMM " ::= { rbNotifications 118 } rbServiceEstablishmentFailure NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo, rbServiceIdx, rbServiceName } STATUS current DESCRIPTION "Service establishment failure, rbTrapSource = NPU, rbTrapSeverity = Minor, rbTrapCategory = QoS rbTrapAdditionalInfo = 200 .. 210, 214 rbServiceIdx = Service Profile Idx, rbServiceName = Service Name is created from User Name(SU MAC) and Service Pipe index." ::= { rbNotifications 119 } rbUserAuthenticationTimeout NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbTrapAdditionalInfo, rbSuMacAddr } STATUS current DESCRIPTION "User authentication timeout, rbTrapSource = NPU rbTrapSeverity = Info, rbTrapCategory = COMM, rbTrapAdditionalInfo = 211 .. 213, rbSuMacAddr = SU MAC." ::= { rbNotifications 120 } rbUserAuthenticationReject NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbSuMacAddr } STATUS current DESCRIPTION "User authentication rejected, rbTrapSource = NPU rbTrapSeverity = Info, rbTrapCategory = COMM, rbSuMacAddr = SU MAC." ::= { rbNotifications 121 } rbAuthenticationServerKeepAliveTimeoutOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbRadiusAuthServerAddress } STATUS current DESCRIPTION "Authentication Server Keep Alive Timeout was detected, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCategory = Equipment, rbRadiusAuthServerAddress = Server IP Address." ::= { rbNotifications 122 } rbAuthenticationServerKeepAliveTimeoutOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbRadiusAuthServerAddress } STATUS current DESCRIPTION "Previously detected Authentication Server Keep Alive Timeout terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment, rbRadiusAuthServerAddress = Server IP Address." ::= { rbNotifications 123 } rbAccountingServerKeepAliveTimeoutOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbRadiusAcctServerAddress } STATUS current DESCRIPTION "Accounting Server Keep Alive Timeout was detected, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCategory = Equipment, rbRadiusAcctServerAddress = Server IP Address." ::= { rbNotifications 124 } rbAccountingServerKeepAliveTimeoutOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory, rbRadiusAcctServerAddress } STATUS current DESCRIPTION "Previously detected Accounting Server Keep Alive Timeout terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment, rbRadiusAcctServerAddress = Server IP Address." ::= { rbNotifications 125 } --======================================================================== -- GPS Related Traps 134 .. 160 --======================================================================== rbExternal1PPSFailureOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "External 1PPS failure was detected. BS will produce this alarm only if external 1PPS clock is enabled, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCategory = Equipment." ::= { rbNotifications 134 } rbExternal1PPSFailureOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "Previously detected External 1PPS failure terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment." ::= { rbNotifications 135 } rbInternal1PPSFailureOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "Internal NPU 1PPS failure was detected, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCategory = Equipment." ::= { rbNotifications 136 } rbInternal1PPSFailureOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "Internal NPU 1PPS failure terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment." ::= { rbNotifications 137 } rbExternal16MHzFailureOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "External 16MHz failure was detected. BS will produce this alarm only if external 16MHz clock is enabled, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCategory = Equipment." ::= { rbNotifications 138 } rbExternal16MHzFailureOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "External 16MHz failure terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment." ::= { rbNotifications 139 } rbInternal16MHzFailureOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "Internal NPU 16MHz failure was detected. Can be produced by all types of BSs, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCategory = Equipment." ::= { rbNotifications 140 } rbInternal16MHzFailureOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "Internal NPU 16MHz failure terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment." ::= { rbNotifications 141 } rbGPSComFailureOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "GPS Com failure was detected. Can be produced only if GPS type is Trimble, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCategory = Equipment." ::= { rbNotifications 142 } rbGPSComFailureOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "GPS Com failure terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment." ::= { rbNotifications 143 } rbGPSHealthyFailureOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "GPS Healthy failure was detected. Can be produced only if GPS type is Trimble, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCategory = Equipment." ::= { rbNotifications 144 } rbGPSHealthyFailureOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "GPS Healthy failure terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment." ::= { rbNotifications 145 } rbMin4SatSyncFailureOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "Min4SatSync failure was detected. This indicated that less than four satellites are received by the GPS. Can be produced only if GPS type is Trimble, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCategory = Equipment." ::= { rbNotifications 146 } rbMin4SatSyncFailureOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "Min4SatSync failure terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment." ::= { rbNotifications 147 } rbAUExternal1PPSFailureOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "External 1PPS failure was detected. Can be produced by AU when the selected 1PPS arriving from active NPU is failed, rbTrapSource = AU, rbTrapSeverity = Major, rbTrapCategory = Equipment." ::= { rbNotifications 148 } rbAUExternal1PPSFailureOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "External 1PPS failure terminated, rbTrapSource = AU, rbTrapSeverity = Info, rbTrapCategory = Equipment." ::= { rbNotifications 149 } rbAUHoldOverEnteredOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "HoldOver Entered was detected. Can be produced by AU when the AU goes to holdover, rbTrapSource = AU, rbTrapSeverity = Major, rbTrapCategory = Equipment." ::= { rbNotifications 150 } rbAUHoldOverEnteredOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "HoldOver Entered terminated, rbTrapSource = AU, rbTrapSeverity = Info, rbTrapCategory = Equipment." ::= { rbNotifications 151 } rbAUHoldOverTimeoutPassedOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "HoldOver passed was detected. Can be produced by AU when the AU holdover passed the Timeout, rbTrapSource = AU, rbTrapSeverity = Major, rbTrapCategory = Equipment." ::= { rbNotifications 152 } rbAUHoldOverTimeoutPassedOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "HoldOver passed terminated, rbTrapSource = AU, rbTrapSeverity = Info, rbTrapCategory = Equipment." ::= { rbNotifications 153 } rbAUHoldOverTxStoppedOn NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "HoldOver passed and Stop TX operation was detected, rbTrapSource = AU, rbTrapSeverity = Major, rbTrapCategory = Equipment." ::= { rbNotifications 154 } rbAUHoldOverTxStoppedOff NOTIFICATION-TYPE OBJECTS { rbTrapSeqNumber, rbTrapSource, rbTrapSeverity, rbTrapCategory } STATUS current DESCRIPTION "Stop TX operation terminated, rbTrapSource = AU, rbTrapSeverity = Info, rbTrapCategory = Equipment." ::= { rbNotifications 155 } END