ADTRAN-TA5K-POTS-MIB DEFINITIONS ::= BEGIN -- TITLE: The ADTRAN Total Access 5000 POTS MIB -- PRODUCT: 1187100L1, 1187100L2, 1187150L1, and more (anything with POTS capability) -- VERSION: 1.3 -- DATE: 11/05/08 -- This MIB defines the management information for the POTS -- modules in a Total Access 5000 shelf. -- Revision History: -- 11/05/2008 PSK - Updated enumeration for adTA5kPotsPortImpedance to include -- recently added z1-z8 impedances. Added new provisioning item -- adTA5kPotsPortAutoImpedanceMode. -- 04/28/2009 PSK - Added new provisioning item adTA5kPotsPortRingVoltage for -- changing the ringer voltage on the VDSL combo card. (And any future -- cards with ringing SLICs.) -- 08/06/2009 BCK - Conversion to V2 MIB -- DO NOT MAKE HISTORY COMMENTS HERE!!!! Revision history now in REVISION/DESCRIPTION clauses below IMPORTS OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY, Integer32 FROM SNMPv2-SMI DisplayString, TruthValue FROM SNMPv2-TC sysName FROM SNMPv2-MIB ifIndex FROM IF-MIB adGenSlotInfoIndex, adGenSlotAlarmStatus FROM ADTRAN-GENSLOT-MIB adGenPortTrapIdentifier, adGenPortInfoIndex FROM ADTRAN-GENPORT-MIB adTrapInformSeqNum FROM ADTRAN-GENTRAPINFORM-MIB adProducts, adMgmt, adIdentity FROM ADTRAN-MIB ; -- ********************************************************************************************************* adTA5kPotsID MODULE-IDENTITY LAST-UPDATED "202201070000Z" ORGANIZATION "Adtran, Inc." CONTACT-INFO "CND Tech Support Postal: ADTRAN, Inc. 901 Explorer Blvd. Huntsville, AL 35806 Tel: +1 800 726-8663 Fax: +1 256 963 6217 E-mail: support@adtran.com" DESCRIPTION "The is the MIB module that describes management information for the POTS. modules in a Total Access 5000 shelf" REVISION "202201070000Z" DESCRIPTION "Added 90 vrms as an option for adTA5kPotsPortRingVoltage." REVISION "201903210000Z" DESCRIPTION "Added adTA5kPotsPulseDigitDetectionEnable to allow the detection of pulse dial digits to be disabled." REVISION "201804020000Z" DESCRIPTION "Added support to access the description for FXS ports" REVISION "201801170000Z" DESCRIPTION "Added adTA5kPotsCardSelfTestLasVegas3Prog to support updates to the selftest->status page for the 48p RPOTS" REVISION "201709250000Z" DESCRIPTION "Added adTA5kPotsCardLineTestScheduleEnable, adTA5kPotsCardLoadCoilTestScheduleEnable, and adTA5kPotsCardLineTestScheduleTimeString to configure the scheduling of fxs line tests" REVISION "201612070000Z" DESCRIPTION "Added adTA5kPotsPortVoiceCallJitterBufferDepth, and adTA5kPotsPortFaxModemCallJitterBufferDepth to get and test the Jitter Buffer values" REVISION "201609080000Z" DESCRIPTION "Added adTA5kPotsPortMwiStatus, adTA5kPotsPortForceMwiOffEvent, and adTA5kPotsPortForceMwiOnEvent to get and test the status of the Message Waiting Indicator" REVISION "201603240000Z" DESCRIPTION "Added support for Message Waiting Indication Provisioning" REVISION "201603080000Z" DESCRIPTION "Added support for Over Temperature Alarm" REVISION "201509290000Z" DESCRIPTION "Added adTA5kPotsLineTestWarbleTone, adTA5kPotsLineTestWarbleToneFreq1, adTA5kPotsLineTestWarbleToneFreq2, and adTA5kPotsLineTestWarbleToneCadence oids to support the new warble tone feature." REVISION "201403060000Z" DESCRIPTION "Added adTA5kPotsPortImpedanceByLoopLength for setting impedances designated by short, medium, or long loop length; added related comment to adTA5kPotsPortImpedance. Also added 85 vrms as an option for adTA5kPotsPortRingVoltage." REVISION "201303250000Z" DESCRIPTION "Added mgcp(3) enumeration to adTA5kPotsCardProvVoiceCallControl in order to maintain consistency with the CLI and Web GUI" REVISION "201108100000Z" DESCRIPTION "PSK - Added tipOpen(10) enumeration and some clarifying comments to adTA5kPotsLineTestLoopState" ::= { adIdentity 753 } -- ******************************************************************************************************** -- OBJECT IDENTIFIERS -- adtran OBJECT IDENTIFIER ::= { enterprises 664 } -- adProducts OBJECT IDENTIFIER ::= { adtran 1 } adTA5kPots OBJECT IDENTIFIER ::= { adProducts 753 } -- adMgmt OBJECT IDENTIFIER ::= { adtran 2 } adTA5kPotsmg OBJECT IDENTIFIER ::= { adMgmt 753 } adTA5kPotsProv OBJECT IDENTIFIER ::= { adTA5kPotsmg 1 } adTA5kPotsStat OBJECT IDENTIFIER ::= { adTA5kPotsmg 2 } adTA5kPotsTest OBJECT IDENTIFIER ::= { adTA5kPotsmg 3 } adTA5kPotsAlarm OBJECT IDENTIFIER ::= { adTA5kPotsmg 4 } adTA5kPotsAlarmEvents OBJECT IDENTIFIER ::= { adTA5kPotsAlarm 0 } -- -- The POTS Card-level provisioning group ************************************************************** -- adTA5kPotsCardProv OBJECT IDENTIFIER ::= { adTA5kPotsProv 1 } adTA5kPotsCardProvTable OBJECT-TYPE SYNTAX SEQUENCE OF AdTA5kPotsCardProvEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The POTS Card-level Provisioning table." ::= { adTA5kPotsCardProv 1 } adTA5kPotsCardProvEntry OBJECT-TYPE SYNTAX AdTA5kPotsCardProvEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the POTS Card-level Provisioning Table." INDEX { adGenSlotInfoIndex } ::= { adTA5kPotsCardProvTable 1 } AdTA5kPotsCardProvEntry ::= SEQUENCE { -- Card-level generic provisioning items adTA5kPotsCardProvRestoreFactoryDefaults INTEGER, -- adTA5kPotsCardProvServiceState INTEGER, -- Card-level POTS/Voice provisioning items -- adTA5kPotsCardProvVoiceCompandingLaw INTEGER, adTA5kPotsCardProvVoiceCallControl INTEGER, adTA5kPotsCardReboot INTEGER, adTA5kPotsCardRemoveBatteryInOosUas INTEGER, adTA5kPotsCardProvLossOfTimingAlarm INTEGER, adTA5kPotsCardProvAllAlarms INTEGER, adTA5kPotsCardLineTestScheduleEnable INTEGER, adTA5kPotsCardLoadCoilTestScheduleEnable INTEGER, adTA5kPotsCardLineTestScheduleTimeString DisplayString } adTA5kPotsCardProvRestoreFactoryDefaults OBJECT-TYPE SYNTAX INTEGER { reset(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "A set command will reset the POTS card. Get has no meaning and will always return 1." ::= { adTA5kPotsCardProvEntry 1 } -- adTA5kPotsCardProvServiceState OBJECT-TYPE -- SYNTAX INTEGER { -- is(1), -- oosUAS(2), -- oosMA(3) -- } -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "POTS card service state- -- 1 = In Service -- 2 = Out Of Service - Unassigned -- 3 = Out Of Service - Maintenance" -- ::= { adTA5kPotsCardProvEntry 2 } -- adTA5kPotsCardProvVoiceCompandingLaw OBJECT-TYPE -- SYNTAX INTEGER { -- u-law(1), -- a-law(2) -- } -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "The audio companding law used for all voice ports on this module - -- 1 = u-law companding (North America, Japan) -- 2 = A-law companding" -- ::= { adTA5kPotsCardProvEntry 2 } adTA5kPotsCardProvVoiceCallControl OBJECT-TYPE SYNTAX INTEGER { tunneledGR303(1), ccSip(2), mgcp(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The call-control protocol for all voice ports on this module - 1 = FXS Signaling (This is the same as tunneledGR303 in the syntax) 2 = ccSip 3 = MGCP" ::= { adTA5kPotsCardProvEntry 2 } adTA5kPotsCardReboot OBJECT-TYPE SYNTAX INTEGER { reboot(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This field sets the card into boot mode 1 = Reboot" ::= { adTA5kPotsCardProvEntry 3 } adTA5kPotsCardRemoveBatteryInOosUas OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Remove CO battery from loop when a port is set to Out of Service - Unassigned. This typically only applies to Combo ADSL/POTS units. 1 = Yes 2 = No" ::= { adTA5kPotsCardProvEntry 4 } adTA5kPotsCardProvLossOfTimingAlarm OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provisioning for Loss Of Timing Alarm which is a card level alarm. 1 = Enable 2 = Disable" ::= { adTA5kPotsCardProvEntry 5 } adTA5kPotsCardProvAllAlarms OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provisioning for All Alarms (Card and Port Level). 1 = Enable 2 = Disable" ::= { adTA5kPotsCardProvEntry 6 } adTA5kPotsCardLineTestScheduleEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable scheduled Fxs Line Tests. If enabled, the card will run a GR-909 line test on each applicable fxs port at the time of day set by the adTA5kPotsCardLineTestScheduleTimeString oid. If disabled, the card will not run any scheduled line tests. 1 = enable 2 = disable" DEFVAL { enable } ::= { adTA5kPotsCardProvEntry 7 } adTA5kPotsCardLoadCoilTestScheduleEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable scheduled Fxs Load Coil Tests. If enabled, the card will run the load coil detection tests in addition to the GR-909 line tests at the time of day set by the adTA5kPotsCardLineTestScheduleTimeString oid. If disabled, the card will not run the load coil detection tests. If adTA5kPotsCardLineTestScheduleEnable is disabled, then this oid has no effect. 1 = enable 2 = disable" DEFVAL { disable } ::= { adTA5kPotsCardProvEntry 8 } adTA5kPotsCardLineTestScheduleTimeString OBJECT-TYPE SYNTAX DisplayString (SIZE(5)) MAX-ACCESS read-write STATUS current DESCRIPTION "Set the scheduled start time of the Line Tests in 24 Hour Format HH:MM. If adTA5kPotsCardLineTestScheduleEnable is disabled, then this oid has no effect." DEFVAL { "02:00" } ::= { adTA5kPotsCardProvEntry 9 } -- -- The POTS Port-level provisioning group **************************************************************** -- adTA5kPotsPortProv OBJECT IDENTIFIER ::= { adTA5kPotsProv 2 } adTA5kPotsPortProvTable OBJECT-TYPE SYNTAX SEQUENCE OF AdTA5kPotsPortProvEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The POTS Port-level Provisioning table." ::= { adTA5kPotsPortProv 1 } adTA5kPotsPortProvEntry OBJECT-TYPE SYNTAX AdTA5kPotsPortProvEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the POTS Port-level Provisioning Table." INDEX { ifIndex } ::= { adTA5kPotsPortProvTable 1 } AdTA5kPotsPortProvEntry ::= SEQUENCE { -- Line-level POTS provisioning items adTA5kPotsPortMode INTEGER, adTA5kPotsPortImpedance INTEGER, adTA5kPotsPortTXTLPString DisplayString, adTA5kPotsPortRXTLPString DisplayString, adTA5kPotsPortOnHookMsg INTEGER, -- adTA5kPotsPortServiceState INTEGER, adTA5kPotsPortTrunkConditioningAlarm INTEGER, adTA5kPotsPortLineShoweringAlarm INTEGER, adTA5kPotsPortAutoImpedanceMode INTEGER, adTA5kPotsPortRingVoltage INTEGER, adTA5kPotsPortImpedanceByLoopLength INTEGER, adTA5kPotsPortOverTempAlarmEnable INTEGER, adTA5kPotsPortMwiType INTEGER, adTA5kPotsPortNeonMwiCadence INTEGER, adTA5kPotsPortNeonMwiVoltage INTEGER, adTA5kPotsPortVoiceCallJitterBufferDepth Integer32, adTA5kPotsPortFaxModemCallJitterBufferDepth Integer32, adTA5kPotsPortCircuitIdentifier DisplayString, adTA5kPotsPulseDigitDetectionEnable TruthValue } adTA5kPotsPortMode OBJECT-TYPE SYNTAX INTEGER { loopStart(1), groundStart(2), tr08SingleParty(3), tr08Uvg(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "POTS port operational Mode - 1 = Loopstart 2 = Groundstart 3 = TR08 Single Party 4 = TR08 UVG" ::= { adTA5kPotsPortProvEntry 1 } -- Note: ohm900(2) and ohm600Plus216uF(3) are no longer supported by the product. -- Setting a port to either of these values will, in fact, change the port to ohm900Plus216uF(4). -- Note: This oid becomes read-only if product uses feature ID 145 (setting impedance by loop length) adTA5kPotsPortImpedance OBJECT-TYPE SYNTAX INTEGER { ohm600(1), ohm900(2), ohm600Plus216uF(3), ohm900Plus216uF(4), ohmz1(5), ohmz2(6), ohmz3(7), ohmz4(8), ohmz5(9), ohmz6(10), ohmz7(11), ohmz8(12) } MAX-ACCESS read-write STATUS current DESCRIPTION "POTS port 2-wire termination impedance - 1 = 600 Ohms 2,3 are no longer supported 4 = 900 Ohms + 2.16 uF 5 = z1 - 220 + (820 // 115nF) 6 = z2 - 270 + (750 // 150nF) 7 = z3 - 270 + (750 // 150nF), Zin = 600r 8 = z4 - 320 + (1050 // 230nF) 9 = z5 - 350 + (1000 // 210nF), Zin = 600r 10 = z6 - 370 + (620 // 310nF) 11 = z7 - 800 // (100 + 50nF), Zin = 900c 12 = z8 - 1650 // (100 + 5nF), Zin = 900c" ::= { adTA5kPotsPortProvEntry 2 } adTA5kPotsPortTXTLPString OBJECT-TYPE SYNTAX DisplayString (SIZE(0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "POTS Port Transmit TLP -9.0dB to +6.0dB" ::= { adTA5kPotsPortProvEntry 3 } adTA5kPotsPortRXTLPString OBJECT-TYPE SYNTAX DisplayString (SIZE(0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "POTS Port Receive TLP -10.0dB to +6.0dB" ::= { adTA5kPotsPortProvEntry 4 } adTA5kPotsPortOnHookMsg OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "POTS Port On-Hook Messaging - 1 = Enable 2 = Disable" ::= { adTA5kPotsPortProvEntry 5 } -- adTA5kPotsPortServiceState OBJECT-TYPE -- SYNTAX INTEGER { -- is(1), -- oosUAS(2), -- oosMA(3) -- } -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "POTS port service state- -- 1 = In Service -- 2 = Out Of Service - Unassigned -- 3 = Out Of Service - Maintenance" -- ::= { adTA5kPotsPortProvEntry 6 } adTA5kPotsPortTrunkConditioningAlarm OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provisioning for Enable/Disable Trunk Conditioning Alarm which is a port level alarm. 1 = Enable 2 = Disable" ::= { adTA5kPotsPortProvEntry 6 } adTA5kPotsPortLineShoweringAlarm OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provisioning for Enable/Disable Line Showering Alarm which is a port level alarm. 1 = Enable 2 = Disable" ::= { adTA5kPotsPortProvEntry 7 } adTA5kPotsPortAutoImpedanceMode OBJECT-TYPE SYNTAX INTEGER { manual(1), automatic(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "POTS Automatic Impedance Mode - 1 = Manual 2 = Automatic" ::= { adTA5kPotsPortProvEntry 8 } -- Note this is only supported by products with an internal ringing SLIC chip. Also the setting "eightyFive" is only valid -- for products that support feature ID 146. The setting "ninety" is only valid for products that support feature ID 221. adTA5kPotsPortRingVoltage OBJECT-TYPE SYNTAX INTEGER { fifty(1), sixty(2), seventy(3), eighty(4), eightyFive(5), ninety(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "POTS Ringer Voltage - 1 = 50 Vrms 2 = 60 Vrms 3 = 70 Vrms 4 = 80 Vrms 5 = 85 Vrms 6 = 90 Vrms" DEFVAL { seventy } ::= { adTA5kPotsPortProvEntry 9 } adTA5kPotsPortImpedanceByLoopLength OBJECT-TYPE SYNTAX INTEGER { loopLengthOther(1), loopLengthShort(2), loopLengthMedium(3), loopLengthLong(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "POTS port 2-wire termination impedance by loop length- 1 = Other - The impedance matches one of the values defined by adTA5kPotsPortImpedance that can not be accurately represented by the values used in this oid. This value is read-only. 2 = Short loop length(< 2.5kft) 3 = Medium loop length (<7.5kft) 4 = Long loop length" DEFVAL { loopLengthShort } ::= { adTA5kPotsPortProvEntry 10 } adTA5kPotsPortOverTempAlarmEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provisioning for Enable/Disable Over Temperature Alarm which is a port level alarm. 1 = Enable 2 = Disable" DEFVAL { enable } ::= { adTA5kPotsPortProvEntry 11 } adTA5kPotsPortMwiType OBJECT-TYPE SYNTAX INTEGER { mwiTypeFsk(1), mwiTypeNeon(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provisioning for the type of Message Waiting Indication for this port to use. 1 = Use Frequency Shift Keying (FSK) to indicate Message Waiting to the phone 2 = Use Neon Voltage to indicate Message Waiting to the phone" DEFVAL { mwiTypeFsk } ::= { adTA5kPotsPortProvEntry 12 } adTA5kPotsPortNeonMwiCadence OBJECT-TYPE SYNTAX INTEGER { neonMwiCadence1000ms(1), neonMwiCadence500ms(2), neonMwiCadence250ms(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provisioning for the flashing cadence of Neon Message Waiting Indication for this port. 1 = Flash the Neon lamp on or off every 1000ms 2 = Flash the Neon lamp on or off every 500ms 3 = Flash the Neon lamp on or off every 250ms" DEFVAL { neonMwiCadence1000ms } ::= { adTA5kPotsPortProvEntry 13 } adTA5kPotsPortNeonMwiVoltage OBJECT-TYPE SYNTAX INTEGER { neonMwiVoltage85volts(1), neonMwiVoltage90volts(2), neonMwiVoltage100volts(3), neonMwiVoltage110volts(4), neonMwiVoltage120volts(5), neonMwiVoltage130volts(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provisioning for the voltage of Neon Message Waiting Indication for this port. 1 = 85 volts 2 = 90 volts 3 = 100 volts 4 = 110 volts 5 = 120 volts 6 = 130 volts" DEFVAL { neonMwiVoltage90volts } ::= { adTA5kPotsPortProvEntry 14 } adTA5kPotsPortVoiceCallJitterBufferDepth OBJECT-TYPE SYNTAX Integer32(0..250) MAX-ACCESS read-write STATUS current DESCRIPTION "Provisioning for the Jitter Buffer Depth used for Voice Calls in mS" DEFVAL { 10 } ::= { adTA5kPotsPortProvEntry 15 } adTA5kPotsPortFaxModemCallJitterBufferDepth OBJECT-TYPE SYNTAX Integer32 (0..250) MAX-ACCESS read-write STATUS current DESCRIPTION "Provisioning for the Jitter Buffer Depth used for Fax Modem Calls in mS" DEFVAL { 80 } ::= { adTA5kPotsPortProvEntry 16 } adTA5kPotsPortCircuitIdentifier OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "The circuit identifier string for the fxs port." ::= { adTA5kPotsPortProvEntry 17 } adTA5kPotsPulseDigitDetectionEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This entry is used to enable or disable the pulse dial digit detection for this port. This entry only applies to fxs ports that are connected to a VoIP service, such as SIP or MGCP. If set to true, then pulse dial digits will be detected from the loop and reported to the voice switch. If set to false, then pulse dial digits will be ignored and will not be reported to the voice switch. This object is true by default." DEFVAL { true } ::= { adTA5kPotsPortProvEntry 18 } -- -- The POTS Card-level status group ********************************************************************** -- adTA5kPotsCardStat OBJECT IDENTIFIER ::= { adTA5kPotsStat 1 } adTA5kPotsCardStatTable OBJECT-TYPE SYNTAX SEQUENCE OF AdTA5kPotsCardStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The POTS Card-level Status table." ::= { adTA5kPotsCardStat 1 } adTA5kPotsCardStatEntry OBJECT-TYPE SYNTAX AdTA5kPotsCardStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the POTS Card-level Status Table." INDEX { adGenSlotInfoIndex } ::= { adTA5kPotsCardStatTable 1 } AdTA5kPotsCardStatEntry ::= SEQUENCE { -- Card-level status items adTA5kPotsCardSelfTestFPGATest INTEGER, adTA5kPotsCardSelfTestFlashTest INTEGER, adTA5kPotsCardSelfTestLasVegas1Prog INTEGER, adTA5kPotsCardSelfTestLasVegas2Prog INTEGER, adTA5kPotsCardSelfTestVineticCodecAProg INTEGER, adTA5kPotsCardSelfTestVineticCodecBProg INTEGER, adTA5kPotsCardSelfTestVineticCodecCProg INTEGER, adTA5kPotsCardSelfTestVineticCodecDProg INTEGER, adTA5kPotsCardSelfTestVineticCodecEProg INTEGER, adTA5kPotsCardSelfTestVineticCodecFProg INTEGER, adTA5kPotsCardSelfTestLasVegas3Prog INTEGER } adTA5kPotsCardSelfTestFPGATest OBJECT-TYPE SYNTAX INTEGER { failed(1), passed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the Self-test FPGA Test Status of the module. 1 = FAILED 2 = PASSED" ::= { adTA5kPotsCardStatEntry 1 } adTA5kPotsCardSelfTestFlashTest OBJECT-TYPE SYNTAX INTEGER { failed(1), passed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the Self-test FPGA Flash Test Status of the module. 1 = FAILED 2 = PASSED" ::= { adTA5kPotsCardStatEntry 2 } adTA5kPotsCardSelfTestLasVegas1Prog OBJECT-TYPE SYNTAX INTEGER { failed(1), passed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the Self-test Las Vegas #1 Programming Status of the module. 1 = FAILED 2 = PASSED" ::= { adTA5kPotsCardStatEntry 3 } adTA5kPotsCardSelfTestLasVegas2Prog OBJECT-TYPE SYNTAX INTEGER { failed(1), passed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the Self-test Las Vegas #2 Programming Status of the module. 1 = FAILED 2 = PASSED" ::= { adTA5kPotsCardStatEntry 4 } adTA5kPotsCardSelfTestVineticCodecAProg OBJECT-TYPE SYNTAX INTEGER { failed(1), passed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the Self-test Vinetic Codec A Programming Status of the module. 1 = FAILED 2 = PASSED" ::= { adTA5kPotsCardStatEntry 5 } adTA5kPotsCardSelfTestVineticCodecBProg OBJECT-TYPE SYNTAX INTEGER { failed(1), passed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the Self-test Vinetic Codec B Programming Status of the module. 1 = FAILED 2 = PASSED" ::= { adTA5kPotsCardStatEntry 6 } adTA5kPotsCardSelfTestVineticCodecCProg OBJECT-TYPE SYNTAX INTEGER { failed(1), passed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the Self-test Vinetic Codec C Programming Status of the module. 1 = FAILED 2 = PASSED" ::= { adTA5kPotsCardStatEntry 7 } adTA5kPotsCardSelfTestVineticCodecDProg OBJECT-TYPE SYNTAX INTEGER { failed(1), passed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the Self-test Vinetic Codec D Programming Status of the module. 1 = FAILED 2 = PASSED" ::= { adTA5kPotsCardStatEntry 8 } adTA5kPotsCardSelfTestVineticCodecEProg OBJECT-TYPE SYNTAX INTEGER { failed(1), passed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the Self-test Vinetic Codec E Programming Status of the module. 1 = FAILED 2 = PASSED" ::= { adTA5kPotsCardStatEntry 9 } adTA5kPotsCardSelfTestVineticCodecFProg OBJECT-TYPE SYNTAX INTEGER { failed(1), passed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the Self-test Vinetic Codec F Programming Status of the module. 1 = FAILED 2 = PASSED" ::= { adTA5kPotsCardStatEntry 10 } adTA5kPotsCardSelfTestLasVegas3Prog OBJECT-TYPE SYNTAX INTEGER { failed(1), passed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the Self-test Las Vegas #3 Programming Status of the module. 1 = FAILED 2 = PASSED" ::= { adTA5kPotsCardStatEntry 11 } -- -- The POTS Line-level status group ********************************************************************** -- adTA5kPotsPortStat OBJECT IDENTIFIER ::= { adTA5kPotsStat 2 } adTA5kPotsPortStatTable OBJECT-TYPE SYNTAX SEQUENCE OF AdTA5kPotsPortStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The POTS Port-level Status table." ::= { adTA5kPotsPortStat 1 } adTA5kPotsPortStatEntry OBJECT-TYPE SYNTAX AdTA5kPotsPortStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the POTS Port-level Status Table." INDEX { ifIndex } ::= { adTA5kPotsPortStatTable 1 } AdTA5kPotsPortStatEntry ::= SEQUENCE { -- Port-level status items adTA5kPotsPortStatLineMode INTEGER, adTA5kPotsPortStatLineActive INTEGER, adTA5kPotsPortStatLineCompression INTEGER, adTA5kPotsPortStatLoopFeed INTEGER, adTA5kPotsPortStatLoopState INTEGER, adTA5kPotsPortStatTestActive INTEGER, adTA5kPotsPortStatServiceState INTEGER, adTA5kPotsPortMwiStatus INTEGER } adTA5kPotsPortStatLineMode OBJECT-TYPE SYNTAX INTEGER { loopStart(1), groundStart(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This item indicates which mode the port is currently operating in. 1 = Loop Start 2 = Ground Start" ::= { adTA5kPotsPortStatEntry 1 } adTA5kPotsPortStatLineActive OBJECT-TYPE SYNTAX INTEGER { active(1), inActive(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This item indicates whether the port is currently active or not. 1 = Active 2 = Not Active" ::= { adTA5kPotsPortStatEntry 2 } adTA5kPotsPortStatLineCompression OBJECT-TYPE SYNTAX INTEGER { g711(1), g726(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This item indicates which type of compression is being used. 1 = G.711 2 = G.726" ::= { adTA5kPotsPortStatEntry 3 } adTA5kPotsPortStatLoopFeed OBJECT-TYPE SYNTAX INTEGER { lcf(1), rlcf(2), osi(3), tipGround(4), ringing(5), powerDown(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This item indicates the loop feed status of the port. 1 = Loop Current Feed 2 = Reverse Loop Current Feed 3 = OSI 4 = Tip Ground 5 = Ringing 6 = Power Down" ::= { adTA5kPotsPortStatEntry 4 } adTA5kPotsPortStatLoopState OBJECT-TYPE SYNTAX INTEGER { loopOpen(1), loopClosed(2), ringGround(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This item indicates the loop state of the port. 1 = Loop Open 2 = Loop Closed 3 = Ring Ground" ::= { adTA5kPotsPortStatEntry 5 } adTA5kPotsPortStatTestActive OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This item indicates whether a test is active on the port or not. 1 = Active 2 = Not Active" ::= { adTA5kPotsPortStatEntry 6 } adTA5kPotsPortStatServiceState OBJECT-TYPE SYNTAX INTEGER { is(1), oosUAS(2), oosMA(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "POTS port service state- 1 = In Service 2 = Out Of Service - Unassigned 3 = Out Of Service - Maintenance" ::= { adTA5kPotsPortStatEntry 7 } adTA5kPotsPortMwiStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), indicatorOff(2), indicatorOn(3), indicatorOffForced(4), indicatorOnForced(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "POTS MWI Status - 1 = Status Unknown 2 = Indicator OFF 3 = Indicator ON 4 = Indicator OFF (forced) 5 = Indicator ON (forced) Note: unknown will always be returned in FXS Signaling mode. This is because a FXS Signaling port has no knowledge of MWI events as they are generated by the voice switch and passed through the port transparently" ::= { adTA5kPotsPortStatEntry 8 } -- -- The POTS Statistics ********************************************************************** -- adTA5kPotsStatistics OBJECT IDENTIFIER ::= { adTA5kPotsStat 3 } -- -- The POTS card-level Statistics group ********************************************************************** -- adTA5kPotscardStatistics OBJECT IDENTIFIER ::= { adTA5kPotsStatistics 1 } adTA5kPotscardStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF AdTA5kPotscardStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The POTS card-level Statistics table." ::= { adTA5kPotscardStatistics 1 } adTA5kPotscardStatisticsEntry OBJECT-TYPE SYNTAX AdTA5kPotscardStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the POTS card-level Statistics Table." INDEX { adGenSlotInfoIndex } ::= { adTA5kPotscardStatisticsTable 1 } AdTA5kPotscardStatisticsEntry ::= SEQUENCE { -- POTS-card Statistics entry adTA5kPotsCardRXEthernetPkts Integer32, adTA5kPotsCardTXEthernetPkts Integer32, adTA5kPotsCardVoiceGatewayTimeouts Integer32, adTA5kPotsCardClearStatistics Integer32, adTA5kPotsPortClearStatistics Integer32 } adTA5kPotsCardRXEthernetPkts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This will give the number of Received ethernet packets" ::= { adTA5kPotscardStatisticsEntry 1 } adTA5kPotsCardTXEthernetPkts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This will give the number of transmitted ethernet packets" ::= { adTA5kPotscardStatisticsEntry 2 } adTA5kPotsCardVoiceGatewayTimeouts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This will give the voice gateway timeouts" ::= { adTA5kPotscardStatisticsEntry 3 } adTA5kPotsCardClearStatistics OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This will clear all the card level statistics when set to 1. A get will always return a 1. 1 = Clear " ::= { adTA5kPotscardStatisticsEntry 4 } adTA5kPotsPortClearStatistics OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This will clear all Port level statistics when set to 1. A get will always return a 1. 1 = Clear " ::= { adTA5kPotscardStatisticsEntry 5 } -- -- The POTS Port-level Statistics group ********************************************************************** -- adTA5kPotsPortStatistics OBJECT IDENTIFIER ::= { adTA5kPotsStatistics 2 } adTA5kPotsPortStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF AdTA5kPotsPortStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The POTS port-level Statistics table." ::= { adTA5kPotsPortStatistics 1 } adTA5kPotsPortStatisticsEntry OBJECT-TYPE SYNTAX AdTA5kPotsPortStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the POTS port-level Statistics Table." INDEX { ifIndex } ::= { adTA5kPotsPortStatisticsTable 1 } AdTA5kPotsPortStatisticsEntry ::= SEQUENCE { -- POTS-port Statistics entry adTA5kPotsPortRXVoicePkts Integer32, adTA5kPotsPortTXVoicePkts Integer32, adTA5kPotsPortRXSignalPkts Integer32, adTA5kPotsPortTXSignalPkts Integer32 } adTA5kPotsPortRXVoicePkts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This will give the number of Received Voice packets" ::= { adTA5kPotsPortStatisticsEntry 1 } adTA5kPotsPortTXVoicePkts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This will give the number of transmitted Voice packets" ::= { adTA5kPotsPortStatisticsEntry 2 } adTA5kPotsPortRXSignalPkts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This will give the number of Received signal packets" ::= { adTA5kPotsPortStatisticsEntry 3 } adTA5kPotsPortTXSignalPkts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This will give the number of transmitted signal packets" ::= { adTA5kPotsPortStatisticsEntry 4 } -- -- The POTS Card-level Test group ************************************************************************ -- adTA5kPotsCardTest OBJECT IDENTIFIER ::= { adTA5kPotsTest 1 } adTA5kPotsCardTestTable OBJECT-TYPE SYNTAX SEQUENCE OF AdTA5kPotsCardTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The POTS Card-level Test table." ::= { adTA5kPotsCardTest 1 } adTA5kPotsCardTestEntry OBJECT-TYPE SYNTAX AdTA5kPotsCardTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the POTS Card-level Test Table." INDEX { adGenSlotInfoIndex } ::= { adTA5kPotsCardTestTable 1 } AdTA5kPotsCardTestEntry ::= SEQUENCE { -- Card-level test items adTA5kPotsCardTestLpbkPotsLine INTEGER, adTA5kPotsCardTestLpbkPotsPayload INTEGER } adTA5kPotsCardTestLpbkPotsLine OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This item enables/disables the POTS line loopback toward the network. 1 = Enable 2 = Disable" ::= { adTA5kPotsCardTestEntry 1 } adTA5kPotsCardTestLpbkPotsPayload OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This item enables/disables the POTS payload loopback toward the network. 1 = Enable 2 = Disable" ::= { adTA5kPotsCardTestEntry 2 } -- -- The POTS Line-level Test group ************************************************************************ -- adTA5kPotsLineTest OBJECT IDENTIFIER ::= { adTA5kPotsTest 2 } adTA5kPotsLineTestTable OBJECT-TYPE SYNTAX SEQUENCE OF AdTA5kPotsLineTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The POTS Line-level Test table." ::= { adTA5kPotsLineTest 1 } adTA5kPotsLineTestEntry OBJECT-TYPE SYNTAX AdTA5kPotsLineTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the POTS Line-level Test Table." INDEX { ifIndex } ::= { adTA5kPotsLineTestTable 1 } AdTA5kPotsLineTestEntry ::= SEQUENCE { -- Line-level test items adTA5kPotsLineTest1004HzTone INTEGER, adTA5kPotsLineTestRingCadence INTEGER, adTA5kPotsLineTestLoopState INTEGER, -- adTA5kPotsLineTestMetallicAccess INTEGER, adTA5kPotsLineClearTest INTEGER, adTA5kPotsLineTestWarbleTone INTEGER, adTA5kPotsLineTestWarbleToneFreq1 INTEGER, adTA5kPotsLineTestWarbleToneFreq2 INTEGER, adTA5kPotsLineTestWarbleToneCadence INTEGER, adTA5kPotsPortForceMwiOffEvent INTEGER, adTA5kPotsPortForceMwiOnEvent INTEGER } adTA5kPotsLineTest1004HzTone OBJECT-TYPE SYNTAX INTEGER { toLoop(1), toNetwork(2), disable(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This item controls the generation of a 1004 Hz test tone from the POTS interface. 1 = To Loop 2 = To Network 3 = Disable" ::= { adTA5kPotsLineTestEntry 1 } adTA5kPotsLineTestRingCadence OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This item enables/disables the ring cadence test on the POTS interface. 1 = Enable 2 = Disable" ::= { adTA5kPotsLineTestEntry 2 } adTA5kPotsLineTestLoopState OBJECT-TYPE SYNTAX INTEGER { disable(1), -- Turn off test activeHigh(2), -- Battery activeLow(3), -- No longer supported reverseActiveHigh(4), -- Reverse Battery reverseActiveLow(5), -- No longer supported powerDownActive(6), -- No longer supported powerDownResistive(7), -- No longer supported tipGround(8), -- No longer supported activeTest(9), -- No longer supported tipOpen(10) -- Tip Open } MAX-ACCESS read-write STATUS current DESCRIPTION "This item controls the loop state test on the POTS interface. 1 = Disable 2 = Active High 3 = Active Low 4 = Reverse Active High 5 = Reverse Active Low 6 = Power Down Active 7 = Power Down Resistive 8 = Tip Ground 9 = Active Test" ::= { adTA5kPotsLineTestEntry 3 } -- adTA5kPotsLineTestMetallicAccess OBJECT-TYPE -- SYNTAX INTEGER { -- active(1), -- inactive(2) -- } -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "This item controls the metallic test access relays for the module. -- 1 = active -- 2 = Inactive (normal)" -- ::= { adTA5kPotsLineTestEntry 4 } adTA5kPotsLineClearTest OBJECT-TYPE SYNTAX INTEGER { clear(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This will clear all Port Line Tests. The get will always return 1. 1 = Clear " ::= { adTA5kPotsLineTestEntry 4 } adTA5kPotsLineTestWarbleTone OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This will enable or disable a warble tone as defined by the oids adTA5kPotsLineTestWarbleToneFreq1, adTA5kPotsLineTestWarbleToneFreq2, and adTA5kPotsLineTestWarbleToneCadence." ::= { adTA5kPotsLineTestEntry 5 } adTA5kPotsLineTestWarbleToneFreq1 OBJECT-TYPE SYNTAX INTEGER { silence(1), tone1004hz(2), tone1400hz(3), tone2040hz(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The first alternating frequency used in the warble tone." ::= { adTA5kPotsLineTestEntry 6 } adTA5kPotsLineTestWarbleToneFreq2 OBJECT-TYPE SYNTAX INTEGER { silence(1), tone1004hz(2), tone1400hz(3), tone2040hz(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The second alternating frequency used in the warble tone." ::= { adTA5kPotsLineTestEntry 7 } adTA5kPotsLineTestWarbleToneCadence OBJECT-TYPE SYNTAX INTEGER { time100ms(1), time250ms(2), time500ms(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The amount of time in ms that one frequency in the warble tone is played before alternating to the the other frequency." ::= { adTA5kPotsLineTestEntry 8 } adTA5kPotsPortForceMwiOffEvent OBJECT-TYPE SYNTAX INTEGER { indicatorOff(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "A set command will force the Message Waiting Indicator for the port to turn OFF. Get has no meaning and will always return indicatorOff(1). This provides a means for MWI events to be forced out to the fxs port locally. After this set has been issued, the port will still perform any subsequent MWI events that may be received from the network." ::= { adTA5kPotsLineTestEntry 9 } adTA5kPotsPortForceMwiOnEvent OBJECT-TYPE SYNTAX INTEGER { indicatorOn(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "A set command will force the Message Waiting Indicator for the port to turn ON. Get has no meaning and will always return indicatorOn(1). This provides a means for MWI events to be forced out to the fxs port locally. After this set has been issued, the port will still perform any subsequent MWI events that may be received from the network." ::= { adTA5kPotsLineTestEntry 10 } -- ------------------------------------- -- POTS Alarms -- ------------------------------------- adTa5kPotsTrunkConditioningTrapClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortInfoIndex } STATUS current DESCRIPTION "Indicates Trunk Conditioning Alarm Clear." --#TYPE "Status - Trunk Conditioning Alarm Clear" --#SUMMARY "POTS: Trunk Conditioning Alarm Clear for" --#SUMMARY "Shelf: %s, Slot %d, Port %d" --#ARGUMENTS {1, 2, 3} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Alarm Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTA5kPotsAlarmEvents 2 } adTa5kPotsTrunkConditioningTrapActive NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortInfoIndex } STATUS current DESCRIPTION "Indicates Trunk Conditioning Alarm Active." --#TYPE "Status - Trunk Conditioning Alarm Active" --#SUMMARY "POTS: Trunk Conditioning Alarm Active for" --#SUMMARY "Shelf: %s, Slot %d, Port %d" --#ARGUMENTS {1, 2, 3} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Alarm Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTA5kPotsAlarmEvents 3 } adTa5kPotsLineShoweringTrapClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortInfoIndex } STATUS current DESCRIPTION "Indicates Line Showering Alarm Clear." --#TYPE "Status - Line Showering Alarm Clear" --#SUMMARY "POTS: Line Showering Alarm Clear for " --#SUMMARY "Shelf: %s, Slot %d, Port %d" --#ARGUMENTS {1, 2, 3} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Alarm Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTA5kPotsAlarmEvents 4 } adTa5kPotsLineShoweringTrapActive NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortInfoIndex } STATUS current DESCRIPTION "Indicates Line Showering Alarm Active." --#TYPE "Status - Line Showering Active" --#SUMMARY "POTS: Line Showering Alarm Active for " --#SUMMARY "Shelf: %s, Slot %d, Port %d" --#ARGUMENTS {1, 2, 3} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Alarm Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTA5kPotsAlarmEvents 5 } adTa5kPotsBackplaneTimingTrapClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortInfoIndex } STATUS current DESCRIPTION "Indicates Backplane Timing Alarm Clear." --#TYPE "Status - Backplane Timing Alarm Clear" --#SUMMARY "POTS: Backplane Timing Alarm Clear for " --#SUMMARY "Shelf: %s, Slot %d, Port %d" --#ARGUMENTS {1, 2, 3} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTA5kPotsAlarmEvents 6 } adTa5kPotsBackplaneTimingTrapActive NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortInfoIndex } STATUS current DESCRIPTION "Indicates Backplane Timing Alarm Active." --#TYPE "Status - Backplane Timing Alarm Active" --#SUMMARY "POTS: Backplane Timing Alarm Active for " --#SUMMARY "Shelf: %s, Slot %d, Port %d" --#ARGUMENTS {1, 2, 3} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTA5kPotsAlarmEvents 7 } adTa5kPotsOverTempTrapClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortInfoIndex } STATUS current DESCRIPTION "Indicates Over Temperature Alarm Clear if the POTS chipset has not indicated, in the last five minutes, that the temperature has risen to a level such that the port will not function." --#TYPE "Status - Over Temperature Alarm Clear" --#SUMMARY "POTS: Over Temperature Alarm Clear for" --#SUMMARY "Shelf: %s, Slot %d, Port %d" --#ARGUMENTS {1, 2, 3} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Alarm Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTA5kPotsAlarmEvents 8 } adTa5kPotsOverTempTrapActive NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adGenSlotInfoIndex, adGenPortInfoIndex } STATUS current DESCRIPTION "Indicates Over Temperature Alarm Active if the POTS chipset has indicated, at least once in the last five minutes, that the temperature for this port has risen to a level such that the port will not function." --#TYPE "Status - Over Temperature Alarm Active" --#SUMMARY "POTS: Over Temperature Alarm Active for " --#SUMMARY "Shelf: %s, Slot %d, Port %d" --#ARGUMENTS {1, 2, 3} --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Alarm Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTA5kPotsAlarmEvents 9 } END