ADTRAN-GENPORT-MIB DEFINITIONS ::= BEGIN -- TITLE: Generic chassis slot port MIB (SMIv2) -- PRODUCT: All chassis type products -- VERSION: 1.0 -- DATE: 99/12/29 -- AUTHOR: Phil Bergstresser -- SNMP: SNMPv2 -- MIB ARC: adtran.adShared.adGenericShelves.adGenPort -- HISTORY: -- 03/10/00 pnb add hyphens to module name -- 03/23/00 pnb add adProductID textual convention -- 03/27/00 pnb add port objects, and unify names -- 04/10/00 pnb remove chassis & slot qualifiers to ifIndex -- 04/12/00 pnb add maps -- 04/18/00 pnb remove redundant slot/port references in port map -- 04/24/00 pnb restore chassis & slot qualifiers from ifIndex -- 04/25/00 pnb Revise map to reverse lookup -- 05/01/00 tgc changed AlarmCondition to AlarmStatus -- 05/03/00 pnb migrated number of ports to genslot MIB. -- 05/04/00 tgc changed adGenPortTrapPortIdentifier to adGenPortTrapIdentifier -- 08/23/00 pnb add port selector virtual object for legacy line cards -- 09/27/00 pnb change port identifier from R/O to R/W and define default. -- 11/03/00 pnb Change ifIndex IMPORT from RFC1213 to IF-MIB -- 11/28/00 pnb Rollback previous IMPORT change to stay SNMPv1 compatible -- 12/19/00 pnb Add ifType to mapping tables to support layered interfaces -- Didn't import IANAIfType to retain SMIv1 compatibility. -- 12/22/00 pnb Reorganize new table for more logical OIDs and add clarifying -- comments. -- 03/01/01 pnb deprecate portSelector and transfer repeaterNumber to genh2tuc.mib -- 04/02/01 pnb change comment on port trap identifier to limit to port only reference. -- 06/08/01 tgc added adGenPortFarEndID to be used to identify end devices without IPs. -- 01/14/02 pnb commented out obsolete adGenPortRepeaterNumber -- 06/13/03 dcc converted to SMIv2; commented out deprecated adGenPortSelector -- 05/14/10 jb Removed DisplayString limit of 20 for adGenPortCustomerUse and adGenIfCustomerUse. IMPORTS OBJECT-TYPE, MODULE-IDENTITY, Integer32, IpAddress FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF ifIndex FROM IF-MIB AdPresence, AdAlarmSeverity, AdProductIdentifier FROM ADTRAN-TC adGenericShelves FROM ADTRAN-GENCHASSIS-MIB adGenSlotInfoIndex FROM ADTRAN-GENSLOT-MIB ; -- Port Group adGenPort MODULE-IDENTITY LAST-UPDATED "200306130000Z" ORGANIZATION "ADTRAN, Inc." CONTACT-INFO " Technical Support Dept. Postal: ADTRAN, Inc. 901 Explorer Blvd. Huntsville, AL 35806 Tel: +1 800 726-8663 Fax: +1 256 963 6217 E-mail: support@adtran.com" DESCRIPTION "The MIB module that describes the generic objects used to mananage individual ports on cards in a shelf/bank developed by ADTRAN, Inc." ::= { adGenericShelves 3 } adGenPortConformance OBJECT IDENTIFIER ::= { adGenPort 99 } adGenPortInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenPortInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of hardware oriented port information on each card. This only includes actual card ports, and not layered logical interfaces. See the adGenPortIfTable for layered interfaces." ::= { adGenPort 3 } adGenPortInfoEntry OBJECT-TYPE SYNTAX AdGenPortInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { adGenSlotInfoIndex, adGenPortInfoIndex } ::= { adGenPortInfoTable 1 } AdGenPortInfoEntry ::= SEQUENCE { adGenPortInfoIndex Integer32, adGenPortInfoState AdPresence, adGenPortIfIndex Integer32, adGenPortDataRate Integer32, -- adGenPortRepeaterNumber -- Integer32, adGenPortFarEndIP IpAddress, adGenPortAlarmStatus OCTET STRING, adGenPortCustomerUse DisplayString, adGenPortTrapIdentifier DisplayString, adGenPortTrapSeverity AdAlarmSeverity, -- adGenPortSelector -- OCTET STRING, adGenPortFarEndID AdProductIdentifier } adGenPortInfoIndex OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value for each physical port on a card. " ::= { adGenPortInfoEntry 1 } adGenPortInfoState OBJECT-TYPE SYNTAX AdPresence MAX-ACCESS read-only STATUS current DESCRIPTION "The state of the card port. Initially it is empty." ::= { adGenPortInfoEntry 3 } adGenPortIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface number identified as ifIndex from the MIB-II interfaces table as defined by the slot and port numbers in this device." ::= { adGenPortInfoEntry 4 } adGenPortDataRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Sets physical port bit rate in bit per second. Zero may imply auto detection." ::= { adGenPortInfoEntry 6 } -- adGenPortRepeaterNumber OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS obsolete -- DESCRIPTION -- "Moved to genh2tuc.mib" -- ::= { adGenPortInfoEntry 7 } adGenPortFarEndIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP address of subtended product, or zero." ::= { adGenPortInfoEntry 8 } adGenPortAlarmStatus OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "A bit encoded string representing the alarm state of the port." ::= { adGenPortInfoEntry 9 } adGenPortCustomerUse OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A character string for any customer use to identify some attribute of the port." ::= { adGenPortInfoEntry 10 } adGenPortTrapIdentifier OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A character string to identify the name of a port. Used for trap varbind in last trap sent. Should default to port number string. Can be overridden by customer as desired." ::= { adGenPortInfoEntry 11 } adGenPortTrapSeverity OBJECT-TYPE SYNTAX AdAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The value for the severity of an alarm trap sent. Used for trap varbind in last trap sent." ::= { adGenPortInfoEntry 12 } -- adGenPortSelector OBJECT-TYPE -- SYNTAX OCTET STRING (SIZE (0|1)) -- MAX-ACCESS read-write -- STATUS deprecated (not ever implemented) -- DESCRIPTION -- "Include this object in a PDU to imply a port for compatibility -- support for legacy products that used community name suffixes." -- ::= { adGenPortInfoEntry 13 } adGenPortFarEndID OBJECT-TYPE SYNTAX AdProductIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "The ADTRAN Product code, 0 if empty. Agent will report real product code when installed or pre-provisioned. This object is visible for all rows. It is defined in the ADTRAN-TC." ::= { adGenPortInfoEntry 14 } -- Slot/Port/Type interface map group -- This table maps the slot, port, & type number from their interface number. -- This optimizes slot, port & type translation from the ifIndex of the -- MIB-2 interfaces table. adGenPortSlotMapTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenPortSlotMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table to map ifIndex to slot, port & type." ::= { adGenPort 4 } adGenPortSlotMapEntry OBJECT-TYPE SYNTAX AdGenPortSlotMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { ifIndex } ::= { adGenPortSlotMapTable 1 } AdGenPortSlotMapEntry ::= SEQUENCE { adGenSlotAddress Integer32, adGenPortAddress Integer32, adGenPortIfType Integer32 } adGenSlotAddress OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The slot in which this port is contained." ::= { adGenPortSlotMapEntry 2 } adGenPortAddress OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The port number within the slot." ::= { adGenPortSlotMapEntry 3 } adGenPortIfType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The IANAIfType of this port" ::= { adGenPortSlotMapEntry 4 } -- Interface Group adGenPortIfInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenPortIfInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maps the MIB-2 interfaces table index from ADTRAN slot, port, and IANA type." ::= { adGenPort 5 } adGenPortIfInfoEntry OBJECT-TYPE SYNTAX AdGenPortIfInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { adGenSlotInfoIndex, adGenPortInfoIndex, adGenIfTypeIndex } ::= { adGenPortIfInfoTable 1 } AdGenPortIfInfoEntry ::= SEQUENCE { adGenIfTypeIndex Integer32, adGenIfIfIndex Integer32, adGenIfCustomerUse DisplayString } adGenIfTypeIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The IANAIfType. It is the ifType of the interface table." ::= { adGenPortIfInfoEntry 1 } adGenIfIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The interface number identified as ifIndex from the MIB-II interfaces table as defined by the ifType, slot and port numbers in this device." ::= { adGenPortIfInfoEntry 4 } adGenIfCustomerUse OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A character string for any customer use to identify some attribute of the port." ::= { adGenPortIfInfoEntry 10 } -- compliance statements -- These two subidentifiers are for local use in this MIB only adGenPortCompliances OBJECT IDENTIFIER ::= { adGenPortConformance 1 } adGenPortMIBGroups OBJECT IDENTIFIER ::= { adGenPortConformance 2 } adGenPortCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities which implement the adtran generic slot MIB." MODULE -- this module MANDATORY-GROUPS { adGenPortBaseGroup } ::= { adGenPortCompliances 1 } adGenPortBaseGroup OBJECT-GROUP OBJECTS { adGenPortInfoState, adGenPortIfIndex, adGenPortDataRate, adGenPortFarEndIP, adGenPortAlarmStatus, adGenPortCustomerUse, adGenPortTrapIdentifier, adGenPortTrapSeverity, adGenPortFarEndID, adGenSlotAddress, adGenPortAddress, adGenPortIfType, adGenIfTypeIndex, adGenIfIfIndex, adGenIfCustomerUse } STATUS current DESCRIPTION "The ADTRAN Generic Port Base Group." ::= { adGenPortMIBGroups 1 } END