ADTRAN-GENMEF-MIB -- TITLE: The ADTRAN MEF MIB -- PRODUCT: Metro Ethernet Products -- VERSION: 1.0 -- DATE: 2/22/07 -- AUTHOR: Joey Boyd -- STATUS: PRELIMINARY -- This MIB defines the object identifier (OID) for the -- ADTRAN GENMEF MIB objects -- HISTORY: -- 2007/02/22 jlb STATUS: PRELIMINARY. -- 2007/02/26 jlb Added adGenMEFMapAssociatedEVC. Placed genMEF into the adEoCu branch. -- 2007/04/02 jlb Changed the ifIndex support to use adGenMEFEVCIndex, adGenMEFMapIndex, -- and adGenMEFProfileIndex -- 2007/04/10 jlb Modified the MIB to be fully SNMPv2 compliant. -- 2007/04/17 jlb Changed the state variables to use RowStatus instead. Changed the Create -- variables to return the next index. -- 2007/04/18 jlb Reordered the tables to group items that are similar. Added the ability to -- to retrieve index values along with the aliases for linked items. -- 2007/04/19 jlb Removed adGenMEFPreDefinedMaps. Added adGenMEFMapBroadcast, adGenMEFMapMulticast, -- adGenMEFMapUnicast, and adGenMEFMapL2CP. -- 2007/04/23 jlb Added adGenMEFEVCEthertype. -- 2007/04/25 jlb Added adGenMEFQueuesTable -- 2007/04/26 jlb Split adGenMEFQueuesTable into adGenMEF10100EthQueuesTable, adGenMEFGigEthQueuesTable, -- and adGenMEFBondGrpQueuesTable -- 2007/05/03 jlb Changed adGenMEFQueueWREDTimeConstant to use an enumerated integer list. -- 2007/05/23 jlb Added adGenMEFUNIMapsByAlias and adGenMEFUNIMapsByIndex. -- Changed adGenMEFEVCEthertype to read-write. -- Added adGenMEFEVCVLANIDPool. -- 2007/06/07 jlb Changed adGenMEFProfileEIR from a DisplayString to an INTEGER -- 2007/08/06 jlb Added commas to the enum for adGenMEFMapCoS fixing a compile error -- 2007/09/04 jlb Changed non enumerated INTEGERs to Integer32 -- 2007/10/02 jlb Added CoS mapping for p-bit values -- 2007/10/31 jlb Added adGenMEFProfileDroppedPackets and changed the CONTACT-INFO. -- 2008/09/09 Subbu Added UNI Anomalies and Traffic Management Performance Data -- 2008/09/23 jsb Reorganized/renamed Traffic Management Performance entries around Policers -- 2008/10/29 jsb Cleaning up varbind lists for policer thresholds changes -- 2009/02/05 jlb Added adGenMEFProfileCommittedInformationRate and adGenMEFProfileExcessInformationRate. -- Deprecated adGenMEFProfileCIR and adGenMEFProfileEIR. -- 2009/02/05 jlb Fixed the description for adGenMEFProfileExcessInformationRate. -- 2009/03/05 sgs Added adGenMEFQosUntagged. -- 2009/11/12 jlb Obsoleted adGenMEFEVCMapsByAlias. Added adGenMEFEVCNumMaps. -- 2010/02/03 jlb Added adGenMEFMapMenCTag and adGenMEFMapMenCTagPri. Added cTagOptionConflict(14) to adGenMEFMapStatus. -- 2010/02/23 rpk Added adGenMEFMapDSCPRange and deprecated adGenMEFMapDSCP -- 2010/05/05 jb Changed description for adGenMEFMapAssociatedEVCIndex -- 2011/01/05 rpk Added adGenMEFMapIpHost. -- ****************************************************************************************** DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY, IpAddress, Unsigned32, Integer32, Gauge32, Counter64 FROM SNMPv2-SMI Unsigned64TC FROM APPLICATION-MIB DisplayString, RowStatus FROM SNMPv2-TC sysName FROM SNMPv2-MIB OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF InterfaceIndex, ifIndex FROM IF-MIB adGenPortTrapIdentifier FROM ADTRAN-GENPORT-MIB adGenMEF, adGenMEFID FROM ADTRAN-SHARED-EOCU-MIB ; adGenMEFMIB MODULE-IDENTITY LAST-UPDATED "201301140000Z" ORGANIZATION "Adtran, Inc." CONTACT-INFO "CND Tech Support Postal: ADTRAN, Inc. 901 Explorer Blvd. Huntsville, AL 35806 Tel: +1 800 726-8663 Fax: +1 256 963 6217 E-mail: support@adtran.com" DESCRIPTION "This MIB defines the objects for the MEF MIB." REVISION "201301140000Z" DESCRIPTION "Added 64 bit Gen Profile oids. As well as updated 32 bit descriptions." REVISION "201002030000Z" DESCRIPTION "Added adGenMEFMapMenCTag and adGenMEFMapMenCTagPri. Added cTagOptionConflict(14) to adGenMEFMapStatus." REVISION "200704050000Z" DESCRIPTION "Created" ::= { adGenMEFID 1 } --================================================================================================================== adGenMEFEvents OBJECT IDENTIFIER ::= {adGenMEF 0} adGenMEFProvisioning OBJECT IDENTIFIER ::= {adGenMEF 1} adGenMEFMibConformance OBJECT IDENTIFIER ::= {adGenMEF 5 } adGenMEFMibGroups OBJECT IDENTIFIER ::= {adGenMEFMibConformance 1 } adGenMEFPerformance OBJECT IDENTIFIER ::= {adGenMEF 6} --================================================================================================================== --================================================================================================================== --================================================================================================================== --================================================================================================================== adGenMEFProvisioningScalars OBJECT IDENTIFIER ::= {adGenMEFProvisioning 1} adGenMEFDeleteAll OBJECT-TYPE SYNTAX INTEGER { deleteAllMaps(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Deletes ALL maps." ::= { adGenMEFProvisioningScalars 2 } adGenMEFEVCIndexNext OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains an appropriate value to be used for adGenMEFEVCIndex when creating entries in the adGenMEFEVCsTable. The value 0 indicates that no unassigned entries are available. The default RowStatus for the newly created index is createAndWait." ::= { adGenMEFProvisioningScalars 3} adGenMEFMapIndexNext OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains an appropriate value to be used for adGenMEFMapIndex when creating entries in the adGenMEFMapsTable. The value 0 indicates that no unassigned entries are available. The default RowStatus for the newly created index is createAndWait." ::= { adGenMEFProvisioningScalars 4} adGenMEFProfileIndexNext OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains an appropriate value to be used for adGenMEFProfileIndex when creating entries in the adGenMEFProfilesTable. The value 0 indicates that no unassigned entries are available. The default RowStatus for the newly created index is createAndWait." ::= { adGenMEFProvisioningScalars 5} adGenMEFEVCEthertype OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable specifies the ethertype used by the EVC. The default value is 0x8100." ::= { adGenMEFProvisioningScalars 6} --================================================================================================================== adGenMEFEVCsTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFEVCsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The EVC provisioning table." ::= { adGenMEFProvisioning 2 } adGenMEFEVCsEntry OBJECT-TYPE SYNTAX AdGenMEFEVCsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the EVC provisioning table." INDEX { adGenMEFEVCIndex } ::= { adGenMEFEVCsTable 1 } AdGenMEFEVCsEntry ::= SEQUENCE { adGenMEFEVCIndex Integer32, adGenMEFEVCRowStatus RowStatus, adGenMEFEVCAlias DisplayString, adGenMEFEVCStatus INTEGER, adGenMEFEVCPort InterfaceIndex, adGenMEFEVCCEVLANIDPreservation INTEGER, adGenMEFEVCVLANID Integer32, adGenMEFEVCMapsByAlias DisplayString, adGenMEFEVCMapsByIndex DisplayString, adGenMEFEVCNumMaps Unsigned32 } adGenMEFEVCIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This variable is used as an index into the EVC table." ::= { adGenMEFEVCsEntry 1} adGenMEFEVCRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to create a new row or modify or delete an existing row in this table." ::= { adGenMEFEVCsEntry 2} adGenMEFEVCAlias OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "A user configurable alias for the EVC. Upon creation of the EVC, the associated alias will default to a unique value." ::= { adGenMEFEVCsEntry 3} adGenMEFEVCStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), running(2), noMapsRunning(3), invalidEVCPort(4), invalidEVCVID(5), disabled(6), evcVIDNotAllowed(7), duplicateEVC(8), vlanMgmtConflict(9), transparentEVCConflict(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable provides the EVC status. If the EVC status is running, then the EVC is applied. If the EVC status is any other value, then the EVC is not applied." ::= { adGenMEFEVCsEntry 4} adGenMEFEVCPort OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "This option provisions the physical port or bonding group for the selected EVC." ::= { adGenMEFEVCsEntry 5} adGenMEFEVCCEVLANIDPreservation OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This option provisions whether to preserve the CE VLAN tag received at the UNI port. Select enabled to push the EVC tag onto the CE tag for frames destined for this EVC. Select disabled to remove the CE VLAN tag and to add the EVC tag for the frames destined for this EVC." ::= { adGenMEFEVCsEntry 6} adGenMEFEVCVLANID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This variable specifies the outermost VLAN s-tag VID for frames on this EVC. Selecting 0 to 4095 will apply a single VLAN s-tag (with this VID). Selecting 4096 will force the EVC to be in transparent mode and no VLAN s-tag will be applied. Selecting 4097 will leave the value unspecified." ::= { adGenMEFEVCsEntry 7} adGenMEFEVCMapsByAlias OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS obsolete DESCRIPTION "This variable lists the maps that are connected to this EVC. The data is represented by a string that is a concatination of the map aliases specified by adGenMEFMapAlias. THIS OBJECT HAS BEEN OBSOLETED." ::= { adGenMEFEVCsEntry 8} adGenMEFEVCMapsByIndex OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This variable lists the maps that are connected to this EVC. The data is represented by a string that is a concatination of the map indices specified by adGenMEFMapIndex." ::= { adGenMEFEVCsEntry 9} adGenMEFEVCNumMaps OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This variable returns the number of maps that are connected to this EVC." ::= { adGenMEFEVCsEntry 10} --================================================================================================================== adGenMEFMapsTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFMapsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Map provisioning table." ::= { adGenMEFProvisioning 3 } adGenMEFMapsEntry OBJECT-TYPE SYNTAX AdGenMEFMapsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Map provisioning table." INDEX { adGenMEFMapIndex } ::= { adGenMEFMapsTable 1 } AdGenMEFMapsEntry ::= SEQUENCE { adGenMEFMapIndex Integer32, adGenMEFMapRowStatus RowStatus, adGenMEFMapAlias DisplayString, adGenMEFMapStatus INTEGER, adGenMEFMapAssociatedEVCAlias DisplayString, adGenMEFMapAssociatedEVCIndex Integer32, adGenMEFMapUNIPort InterfaceIndex, adGenMEFMapCEVLANID Integer32, adGenMEFMapCEVLANPRI DisplayString, adGenMEFMapDSCP Integer32, adGenMEFMapUntagged INTEGER, adGenMEFMapCoS INTEGER, adGenMEFMapAttachedProfileAlias DisplayString, adGenMEFMapAttachedProfileIndex Integer32, adGenMEFMapBroadcast INTEGER, adGenMEFMapMulticast INTEGER, adGenMEFMapUnicast INTEGER, adGenMEFMapL2CP INTEGER, adGenMEFMapMenCTag INTEGER, adGenMEFMapMenCTagPri INTEGER, adGenMEFMapDSCPRange DisplayString, adGenMEFMapIpHost OCTET STRING } adGenMEFMapIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This variable is used as an index into the Map table." ::= { adGenMEFMapsEntry 1} adGenMEFMapRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to create a new row or modify or delete an existing row in this table." ::= { adGenMEFMapsEntry 2} adGenMEFMapAlias OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "A user configurable alias for the Map. Upon creation of the Map, the associated alias will default to a unique value." ::= { adGenMEFMapsEntry 3} adGenMEFMapStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), running(2), noEVCconnected(3), evcNotRunning(4), invalidUNIport(5), disabled(6), duplicateMap(7), vlanMGMTconflict(8), tagOptionConflict(9), excessUNIsPerEVC(10), uniPortEqualEVCPort(11), preserveConflict(12), resourcesUnavailable(13), cTagOptionConflict(14) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable provides the Map status. If the Map status is running, then the Map is applied. If the Map status is any other value, then the Map is not applied." ::= { adGenMEFMapsEntry 4} adGenMEFMapAssociatedEVCAlias OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This option is used to configure the EVC, based on the EVC alias (adGenMEFEVCAlias) that is associated with this Map." ::= { adGenMEFMapsEntry 5} adGenMEFMapAssociatedEVCIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "A number greater than zero is used to configure the EVC, based on the EVC index (adGenMEFEVCIndex) that is associated with this Map. A -1 is used to connect discard the EVC that is associated with this Map. A zero means no EVC is associated with this map." ::= { adGenMEFMapsEntry 6} adGenMEFMapUNIPort OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "This option provisions the physical port or bonding group at which the customer frame is received." ::= { adGenMEFMapsEntry 7} adGenMEFMapCEVLANID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This option specifies the VID of the outermost tag of the ingress (CE) frame at the UNI port. Selecting 0 to 4095 specifies the CE VLAN ID using the selected value. Selecting 4096 leaves the value unspecified." ::= { adGenMEFMapsEntry 8} adGenMEFMapCEVLANPRI OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This option is used to specify a list of allowable P-bit values of the outermost VLAN tag of the ingress (CE) frame as it is received on the UNI port. This option is only valid if the adGenMEFMapCEVLANID is specified. Example values: Empty string = Unspecified 0,1,2 = P-bit values 0,1,2 0-2,5-7 = P-bit values 0,1,2,5,6,7" ::= { adGenMEFMapsEntry 9} adGenMEFMapDSCP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS deprecated DESCRIPTION "This option is the specific DSCP value of the ingress frame at the UNI port. This option is only valid if the adGenMEFMapCEVLANID is specified. The DSCP value is specified by selecting 0 to 63. 64 is used for unspecified. 65 is used to specify a range has been configured that cannot be represented by this OID." ::= { adGenMEFMapsEntry 10} adGenMEFMapUntagged OBJECT-TYPE SYNTAX INTEGER { disallow(1), allow(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This option is only valid if the adGenMEFMapCEVLANID is specified. It is used to control whether to allow untagged and priority tagged frames to ingress the UNI port in addition to frames tagged with the specified CE VLAN ID." ::= { adGenMEFMapsEntry 11} adGenMEFMapCoS OBJECT-TYPE SYNTAX INTEGER { explicit0(1), explicit1(2), explicit2(3), explicit3(4), explicit4(5), explicit5(6), explicit6(7), explicit7(8), inheritFromCEVLANPbits(9) } MAX-ACCESS read-create STATUS current DESCRIPTION "This option controls how the frames are classified for this Map. The CoS can be set explicitly or inherited from the CE VLAN P-bit value." ::= { adGenMEFMapsEntry 12} adGenMEFMapAttachedProfileAlias OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This variable shows the profile that is attached to this map. The profile is represented by its alias given by adGenMEFProfileAlias." ::= { adGenMEFMapsEntry 13} adGenMEFMapAttachedProfileIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This variable shows the profile that is attached to this map. The profile is represented by its index given by adGenMEFProfileIndex." ::= { adGenMEFMapsEntry 14} adGenMEFMapBroadcast OBJECT-TYPE SYNTAX INTEGER { disallow(1), allow(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This option is used to control whether to allow broadcast traffic to ingress the UNI port." ::= { adGenMEFMapsEntry 15} adGenMEFMapMulticast OBJECT-TYPE SYNTAX INTEGER { disallow(1), allow(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This option is used to control whether to allow multicast traffic to ingress the UNI port." ::= { adGenMEFMapsEntry 16} adGenMEFMapUnicast OBJECT-TYPE SYNTAX INTEGER { disallow(1), allow(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This option is used to control whether to allow unicast traffic to ingress the UNI port." ::= { adGenMEFMapsEntry 17} adGenMEFMapL2CP OBJECT-TYPE SYNTAX INTEGER { disallow(1), allow(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This option is used to control whether to allow L2CP traffic to ingress the UNI port." ::= { adGenMEFMapsEntry 18} adGenMEFMapMenCTag OBJECT-TYPE SYNTAX INTEGER(2..4095) MAX-ACCESS read-create STATUS current DESCRIPTION "Specify the c-tag to be applied on traffic egressing the connected EVC. A value of 4095 indicates that no c-tag is applied." ::= { adGenMEFMapsEntry 19} adGenMEFMapMenCTagPri OBJECT-TYPE SYNTAX INTEGER { explicit0(1), explicit1(2), explicit2(3), explicit3(4), explicit4(5), explicit5(6), explicit6(7), explicit7(8), inheritFromCEVLANPbits(9) } MAX-ACCESS read-create STATUS current DESCRIPTION "This option controls how the frames are classified for this Map. The c-tag p-bits can be set explicitly or inherited from the CE VLAN P-bit value." ::= { adGenMEFMapsEntry 20} adGenMEFMapDSCPRange OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This option specifies a list of allowable DSCP values on the ingress frames at the UNI port. Each DSCP value can be from 0 to 63. Example values: Empty string = Unspecified 0,1,2 = DSCP values 0,1,2 0-2,5-7 = DSCP values 0,1,2,5,6,7" ::= { adGenMEFMapsEntry 21} adGenMEFMapIpHost OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..84)) MAX-ACCESS read-create STATUS current DESCRIPTION "This option connects the evc-map to an existing IP-Host in the system. Setting the string to zero-length will clear the IP-Host connection. To connect an IP-host, the octet string is formatted as follows: Octets 0-3: 32-bit ifIndex of slot where IP-Host is located Octets 4-n: Ascii encoding of IP-Host name. n can range from 5-83, allowing from 1 to 80 character IP-Host name. Example: IP-Host 'ip' (i = 0x69, p = 0x70) on slot 2, where slot 2 has an ifIndex of 2,999,999 (0x002DC6BF) The value of this OID would be: 00.2D.C6.BF.69.70 " ::= { adGenMEFMapsEntry 22 } --================================================================================================================== adGenMEFProfilesTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFProfilesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Profile provisioning table." ::= { adGenMEFProvisioning 4 } adGenMEFProfilesEntry OBJECT-TYPE SYNTAX AdGenMEFProfilesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Profile provisioning table." INDEX { adGenMEFProfileIndex } ::= { adGenMEFProfilesTable 1 } AdGenMEFProfilesEntry ::= SEQUENCE { adGenMEFProfileIndex Integer32, adGenMEFProfileRowStatus RowStatus, adGenMEFProfileAlias DisplayString, adGenMEFProfileStatus INTEGER, adGenMEFProfileApp INTEGER, adGenMEFProfileUNIPort InterfaceIndex, adGenMEFProfileEVC Integer32, adGenMEFProfileCoSValue DisplayString, adGenMEFProfileRateCoupling INTEGER, adGenMEFProfileCIR Integer32, adGenMEFProfileCBS Integer32, adGenMEFProfileEIR Integer32, adGenMEFProfileEBS Integer32, adGenMEFProfileAddMap DisplayString, adGenMEFProfileRemoveMap DisplayString, adGenMEFProfileMapsByAlias DisplayString, adGenMEFProfileMapsByIndex DisplayString, adGenMEFProfileDroppedPackets Gauge32, adGenMEFProfileCommittedInformationRate Integer32, adGenMEFProfileExcessInformationRate Integer32 } adGenMEFProfileIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This variable is used as an index into the Profiles table." ::= { adGenMEFProfilesEntry 1} adGenMEFProfileRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to create a new row or modify or delete an existing row in this table." ::= { adGenMEFProfilesEntry 2} adGenMEFProfileAlias OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "A user configurable alias for the Profile. Upon creation of the Profile, the associated alias will default to a unique value." ::= { adGenMEFProfilesEntry 3} adGenMEFProfileStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), running(2), disabled(3), invalidUNIPort(4), invalidEVC(5), duplicateProfile(6), invalidRates(7), invalidApplication(8), invalidCoS(9), mapConflict(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable provides the Profile status. If the Profile status is running, then the Profile is applied. If the Profile status is any other value, then the Profile is not applied." ::= { adGenMEFProfilesEntry 4} adGenMEFProfileApp OBJECT-TYPE SYNTAX INTEGER { unspecified(1), uniPort(2), evc(3), ceVLANCoS(4), custom(5) } MAX-ACCESS read-create STATUS current DESCRIPTION "This variable provides the scope of the profile. For uniPort, the profile is applied to all maps of a specific UNI port. For EVC, the profile is applied to all maps associated with a specific EVC. For ceVLANCoS, the profile is applied to a set of CoS values for a given EVC. For custom, the profile is applied to all maps added to the profile using adGenMEFProfileAddMap." ::= { adGenMEFProfilesEntry 5} adGenMEFProfileUNIPort OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "The variable is used if adGenMEFProfileApp is set to uniPort." ::= { adGenMEFProfilesEntry 6} adGenMEFProfileEVC OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The variable is used if adGenMEFProfileApp is set to evc or ceVLANCoS. The value is the adGenMEFEVCIndex of the EVC." ::= { adGenMEFProfilesEntry 7} adGenMEFProfileCoSValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "The variable is used if adGenMEFProfileApp is set to ceVLANCoS. Example values: Empty string = Unspecified 0,1,2 = P-bit values 0,1,2 0-2,5-7 = P-bit values 0,1,2,5,6,7" ::= { adGenMEFProfilesEntry 8} adGenMEFProfileRateCoupling OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This variable controls the relationship of the CIR to the EIR. If enabled, the EIR value is additive to the CIR. If disabled, the EIR is inclusive of the CIR." ::= { adGenMEFProfilesEntry 9} adGenMEFProfileCIR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS deprecated DESCRIPTION "This variable is used to configure the CIR (in kbps)." ::= { adGenMEFProfilesEntry 10} adGenMEFProfileCBS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This variable is used to configure the CBS (in bytes)." ::= { adGenMEFProfilesEntry 11} adGenMEFProfileEIR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS deprecated DESCRIPTION "This variable is used to configure the EIR (in kbps). A null string is used to configure the EIR for no limit. The maximum CIR value is 100000." ::= { adGenMEFProfilesEntry 12} adGenMEFProfileEBS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This variable is used to configure the EBS (in bytes)." ::= { adGenMEFProfilesEntry 13} adGenMEFProfileAddMap OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This variable is used to add a map to the profile. The map is referenced by adGenMEFMapAlias. This is only applicable when adGenMEFProfileApp is set to custom(5)." ::= { adGenMEFProfilesEntry 14} adGenMEFProfileRemoveMap OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This variable is used to remove a map from the profile. The map is referenced by adGenMEFMapAlias. This is only applicable when adGenMEFProfileApp is set to custom(5)." ::= { adGenMEFProfilesEntry 15} adGenMEFProfileMapsByAlias OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This variable lists the maps that are connected to this profile. The data is represented by a string that is a concatination of the map aliases specified by adGenMEFMapAlias." ::= { adGenMEFProfilesEntry 16} adGenMEFProfileMapsByIndex OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This variable lists the maps that are connected to this profile. The data is represented by a string that is a concatination of the map indices specified by adGenMEFMapIndex." ::= { adGenMEFProfilesEntry 17} adGenMEFProfileDroppedPackets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the packets dropped due to this profile's bandwidth restriction (CIR + EIR)." ::= { adGenMEFProfilesEntry 18} adGenMEFProfileCommittedInformationRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This variable is used to configure the CIR (in kbps)." ::= { adGenMEFProfilesEntry 19} adGenMEFProfileExcessInformationRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This variable is used to configure the EIR (in kbps). A SET to a value of -1 is used to configure the EIR for no limit." ::= { adGenMEFProfilesEntry 20} --================================================================================================================== adGenMEFQueueScalars OBJECT IDENTIFIER ::= { adGenMEFProvisioning 5 } adGenMEFQueueWREDTimeConstant OBJECT-TYPE SYNTAX INTEGER { approx2ms(1), approx4ms(2), approx8ms(3), approx16ms(4), approx32ms(5), approx62ms(6), approx125ms(7), approx250ms(8), approx500ms(9) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED time constant for all queues." ::= { adGenMEFQueueScalars 1} adGenMEFQueueCoSMapForPri0 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the CoS queue that all traffic with a p-bit value of 0 gets mapped into. The valid range is 0 - 7 where 7 gets treated with the highest priority. The default value is 1 per IEEE 802.1Q-2005" ::= { adGenMEFQueueScalars 2} adGenMEFQueueCoSMapForPri1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the CoS queue that all traffic with a p-bit value of 1 gets mapped into. The valid range is 0 - 7 where 7 gets treated with the highest priority. The default value is 0 per IEEE 802.1Q-2005" ::= { adGenMEFQueueScalars 3} adGenMEFQueueCoSMapForPri2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the CoS queue that all traffic with a p-bit value of 2 gets mapped into. The valid range is 0 - 7 where 7 gets treated with the highest priority. The default value is 2 per IEEE 802.1Q-2005" ::= { adGenMEFQueueScalars 4} adGenMEFQueueCoSMapForPri3 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the CoS queue that all traffic with a p-bit value of 3 gets mapped into. The valid range is 0 - 7 where 7 gets treated with the highest priority. The default value is 3 per IEEE 802.1Q-2005" ::= { adGenMEFQueueScalars 5} adGenMEFQueueCoSMapForPri4 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the CoS queue that all traffic with a p-bit value of 4 gets mapped into. The valid range is 0 - 7 where 7 gets treated with the highest priority. The default value is 4 per IEEE 802.1Q-2005" ::= { adGenMEFQueueScalars 6} adGenMEFQueueCoSMapForPri5 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the CoS queue that all traffic with a p-bit value of 5 gets mapped into. The valid range is 0 - 7 where 7 gets treated with the highest priority. The default value is 5 per IEEE 802.1Q-2005" ::= { adGenMEFQueueScalars 7} adGenMEFQueueCoSMapForPri6 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the CoS queue that all traffic with a p-bit value of 6 gets mapped into. The valid range is 0 - 7 where 7 gets treated with the highest priority. The default value is 6 per IEEE 802.1Q-2005" ::= { adGenMEFQueueScalars 8} adGenMEFQueueCoSMapForPri7 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the CoS queue that all traffic with a p-bit value of 7 gets mapped into. The valid range is 0 - 7 where 7 gets treated with the highest priority. The default value is 7 per IEEE 802.1Q-2005" ::= { adGenMEFQueueScalars 9} adGenMEFQosUntagged OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the MEN priority for untagged traffic. The valid range is 0 - 7 where 7 gets treated with the highest priority. The default value is 0 per IEEE 802.1Q-2005" ::= { adGenMEFQueueScalars 10} --================================================================================================================== adGenMEF10100EthQueuesTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEF10100EthQueuesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The 10/100 Ethernet Queue provisioning table." ::= { adGenMEFProvisioning 6 } adGenMEF10100EthQueuesEntry OBJECT-TYPE SYNTAX AdGenMEF10100EthQueuesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the 10/100 Ethernet Queue provisioning table." INDEX { ifIndex, adGenMEF10100EthCoSIndex } ::= { adGenMEF10100EthQueuesTable 1 } AdGenMEF10100EthQueuesEntry ::= SEQUENCE { adGenMEF10100EthCoSIndex Integer32, adGenMEF10100EthQueueMaxDepth Integer32, adGenMEF10100EthQueueWREDState INTEGER, adGenMEF10100EthQueueWREDGreenMaxThresh Integer32, adGenMEF10100EthQueueWREDGreenMinThresh Integer32, adGenMEF10100EthQueueWREDGreenDropProb Integer32, adGenMEF10100EthQueueWREDYellowMaxThresh Integer32, adGenMEF10100EthQueueWREDYellowMinThresh Integer32, adGenMEF10100EthQueueWREDYellowDropProb Integer32 } adGenMEF10100EthCoSIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This index represents the CoS value associated with the queue. The value of the index is obtained by adding one(1) to the CoS value (e.g. CoS 0 = CoSIndex 1)." ::= { adGenMEF10100EthQueuesEntry 1} adGenMEF10100EthQueueMaxDepth OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the maximum depth of the selected 10/100 Ethernet queue." ::= { adGenMEF10100EthQueuesEntry 2} adGenMEF10100EthQueueWREDState OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED state of the selected 10/100 Ethernet queue." ::= { adGenMEF10100EthQueuesEntry 3} adGenMEF10100EthQueueWREDGreenMaxThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED maximum green traffic threshold of the selected 10/100 Ethernet queue." ::= { adGenMEF10100EthQueuesEntry 4} adGenMEF10100EthQueueWREDGreenMinThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED minimum green traffic threshold of the selected 10/100 Ethernet queue." ::= { adGenMEF10100EthQueuesEntry 5} adGenMEF10100EthQueueWREDGreenDropProb OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED drop probability of the green traffic in the selected 10/100 Ethernet queue." ::= { adGenMEF10100EthQueuesEntry 6} adGenMEF10100EthQueueWREDYellowMaxThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED maximum yellow traffic threshold of the selected 10/100 Ethernet queue." ::= { adGenMEF10100EthQueuesEntry 7} adGenMEF10100EthQueueWREDYellowMinThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED minimum yellow traffic threshold of the selected 10/100 Ethernet queue." ::= { adGenMEF10100EthQueuesEntry 8} adGenMEF10100EthQueueWREDYellowDropProb OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED drop probability of the yellow traffic in the selected 10/100 Ethernet queue." ::= { adGenMEF10100EthQueuesEntry 9} --================================================================================================================== adGenMEFGigEthQueuesTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFGigEthQueuesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Gigabit Ethernet Queue provisioning table." ::= { adGenMEFProvisioning 7 } adGenMEFGigEthQueuesEntry OBJECT-TYPE SYNTAX AdGenMEFGigEthQueuesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Gigabit Ethernet Queue provisioning table." INDEX { ifIndex, adGenMEFGigEthCoSIndex } ::= { adGenMEFGigEthQueuesTable 1 } AdGenMEFGigEthQueuesEntry ::= SEQUENCE { adGenMEFGigEthCoSIndex Integer32, adGenMEFGigEthQueueMaxDepth Integer32, adGenMEFGigEthQueueWREDState INTEGER, adGenMEFGigEthQueueWREDGreenMaxThresh Integer32, adGenMEFGigEthQueueWREDGreenMinThresh Integer32, adGenMEFGigEthQueueWREDGreenDropProb Integer32, adGenMEFGigEthQueueWREDYellowMaxThresh Integer32, adGenMEFGigEthQueueWREDYellowMinThresh Integer32, adGenMEFGigEthQueueWREDYellowDropProb Integer32 } adGenMEFGigEthCoSIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This index represents the CoS value associated with the queue. The value of the index is obtained by adding one(1) to the CoS value (e.g. CoS 0 = CoSIndex 1)." ::= { adGenMEFGigEthQueuesEntry 1} adGenMEFGigEthQueueMaxDepth OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the maximum depth of the selected Gigabit Ethernet queue." ::= { adGenMEFGigEthQueuesEntry 2} adGenMEFGigEthQueueWREDState OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED state of the selected Gigabit Ethernet queue." ::= { adGenMEFGigEthQueuesEntry 3} adGenMEFGigEthQueueWREDGreenMaxThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED maximum green traffic threshold of the selected Gigabit Ethernet queue." ::= { adGenMEFGigEthQueuesEntry 4} adGenMEFGigEthQueueWREDGreenMinThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED minimum green traffic threshold of the selected Gigabit Ethernet queue." ::= { adGenMEFGigEthQueuesEntry 5} adGenMEFGigEthQueueWREDGreenDropProb OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED drop probability of the green traffic in the selected Gigabit Ethernet queue." ::= { adGenMEFGigEthQueuesEntry 6} adGenMEFGigEthQueueWREDYellowMaxThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED maximum yellow traffic threshold of the selected Gigabit Ethernet queue." ::= { adGenMEFGigEthQueuesEntry 7} adGenMEFGigEthQueueWREDYellowMinThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED minimum yellow traffic threshold of the selected Gigabit Ethernet queue." ::= { adGenMEFGigEthQueuesEntry 8} adGenMEFGigEthQueueWREDYellowDropProb OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED drop probability of the yellow traffic in the selected Gigabit Ethernet queue." ::= { adGenMEFGigEthQueuesEntry 9} --================================================================================================================== adGenMEFBondGrpQueuesTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFBondGrpQueuesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The bonding group Queue provisioning table." ::= { adGenMEFProvisioning 8 } adGenMEFBondGrpQueuesEntry OBJECT-TYPE SYNTAX AdGenMEFBondGrpQueuesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the bonding group Queue provisioning table." INDEX { ifIndex, adGenMEFBondGrpCoSIndex } ::= { adGenMEFBondGrpQueuesTable 1 } AdGenMEFBondGrpQueuesEntry ::= SEQUENCE { adGenMEFBondGrpCoSIndex Integer32, adGenMEFBondGrpQueueMaxDepth Integer32, adGenMEFBondGrpQueueWREDState INTEGER, adGenMEFBondGrpQueueWREDGreenMaxThresh Integer32, adGenMEFBondGrpQueueWREDGreenMinThresh Integer32, adGenMEFBondGrpQueueWREDGreenDropProb Integer32, adGenMEFBondGrpQueueWREDYellowMaxThresh Integer32, adGenMEFBondGrpQueueWREDYellowMinThresh Integer32, adGenMEFBondGrpQueueWREDYellowDropProb Integer32 } adGenMEFBondGrpCoSIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This index represents the CoS value associated with the queue. The value of the index is obtained by adding one(1) to the CoS value (e.g. CoS 0 = CoSIndex 1)." ::= { adGenMEFBondGrpQueuesEntry 1} adGenMEFBondGrpQueueMaxDepth OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the maximum depth of the selected bonding group queue." ::= { adGenMEFBondGrpQueuesEntry 2} adGenMEFBondGrpQueueWREDState OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED state of the selected bonding group queue." ::= { adGenMEFBondGrpQueuesEntry 3} adGenMEFBondGrpQueueWREDGreenMaxThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED maximum green traffic threshold of the selected bonding group queue." ::= { adGenMEFBondGrpQueuesEntry 4} adGenMEFBondGrpQueueWREDGreenMinThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED minimum green traffic threshold of the selected bonding group queue." ::= { adGenMEFBondGrpQueuesEntry 5} adGenMEFBondGrpQueueWREDGreenDropProb OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED drop probability of the green traffic in the selected bonding group queue." ::= { adGenMEFBondGrpQueuesEntry 6} adGenMEFBondGrpQueueWREDYellowMaxThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED maximum yellow traffic threshold of the selected bonding group queue." ::= { adGenMEFBondGrpQueuesEntry 7} adGenMEFBondGrpQueueWREDYellowMinThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED minimum yellow traffic threshold of the selected bonding group queue." ::= { adGenMEFBondGrpQueuesEntry 8} adGenMEFBondGrpQueueWREDYellowDropProb OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is used to provision the WRED drop probability of the yellow traffic in the selected bonding group queue." ::= { adGenMEFBondGrpQueuesEntry 9} --================================================================================================================== adGenMEFUNITable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFUNIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The UNI provisioning table." ::= { adGenMEFProvisioning 9 } adGenMEFUNIEntry OBJECT-TYPE SYNTAX AdGenMEFUNIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the UNI provisioning table." INDEX { ifIndex } ::= { adGenMEFUNITable 1 } AdGenMEFUNIEntry ::= SEQUENCE { adGenMEFUNIMapsByAlias DisplayString, adGenMEFUNIMapsByIndex DisplayString } adGenMEFUNIMapsByAlias OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This variable lists the maps that are connected to this UNI. The data is represented by a string that is a concatination of the map aliases specified by adGenMEFMapAlias." ::= { adGenMEFUNIEntry 1} adGenMEFUNIMapsByIndex OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This variable lists the maps that are connected to this UNI. The data is represented by a string that is a concatination of the map indices specified by adGenMEFMapIndex." ::= { adGenMEFUNIEntry 2} --================================================================================================================== adGenMEFMENTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFMENEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The MEN provisioning table." ::= { adGenMEFProvisioning 10 } adGenMEFMENEntry OBJECT-TYPE SYNTAX AdGenMEFMENEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the MEN provisioning table." INDEX { ifIndex } ::= { adGenMEFMENTable 1 } AdGenMEFMENEntry ::= SEQUENCE { adGenMEFMENVLANIDPool DisplayString } adGenMEFMENVLANIDPool OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object is a text string listing the available VLAN IDs to use in EVC creation per MEN port. If a restricted pool has been provisioned the string will return the VLANs separated by commas. If no pool has been provisioned, the string will read All." ::= { adGenMEFMENEntry 1} --================================================================================================================== adGenMEF10100EthAnomaliesPerformance OBJECT IDENTIFIER ::= { adGenMEFPerformance 1 } adGenMEF10100EthAnomalies15MinCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEF10100EthAnomalies15MinCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The 10/100 Ethernet MEF Anomalies 15Min current table." ::= { adGenMEF10100EthAnomaliesPerformance 1 } adGenMEF10100EthAnomalies15MinCurrentEntry OBJECT-TYPE SYNTAX AdGenMEF10100EthAnomalies15MinCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the 10/100 Ethernet MEF Anomalies 15Min current table." INDEX { ifIndex } ::= { adGenMEF10100EthAnomalies15MinCurrentTable 1 } AdGenMEF10100EthAnomalies15MinCurrentEntry ::= SEQUENCE { adGenMEF10100EthAnomalies15MinCurrentFramesWithInvalidCEVLANID Gauge32 } adGenMEF10100EthAnomalies15MinCurrentFramesWithInvalidCEVLANID OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with invalid CE-VLAN id." ::= { adGenMEF10100EthAnomalies15MinCurrentEntry 1 } --================================================================================================================== adGenMEF10100EthAnomalies15MinIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEF10100EthAnomalies15MinIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The 10/100 Ethernet MEF Anomalies 15Min interval table." ::= { adGenMEF10100EthAnomaliesPerformance 2 } adGenMEF10100EthAnomalies15MinIntervalEntry OBJECT-TYPE SYNTAX AdGenMEF10100EthAnomalies15MinIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the 10/100 Ethernet MEF Anomalies 15Min interval table." INDEX { ifIndex, adGenMEF10100EthAnomalies15MinIntervalNumber } ::= { adGenMEF10100EthAnomalies15MinIntervalTable 1 } AdGenMEF10100EthAnomalies15MinIntervalEntry ::= SEQUENCE { adGenMEF10100EthAnomalies15MinIntervalNumber Integer32, adGenMEF10100EthAnomalies15MinIntervalFramesWithInvalidCEVLANID Gauge32 } adGenMEF10100EthAnomalies15MinIntervalNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { adGenMEF10100EthAnomalies15MinIntervalEntry 1 } adGenMEF10100EthAnomalies15MinIntervalFramesWithInvalidCEVLANID OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with invalid CE-VLAN id." ::= { adGenMEF10100EthAnomalies15MinIntervalEntry 2 } --================================================================================================================== adGenMEF10100EthAnomalies24HrCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEF10100EthAnomalies24HrCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The 10/100 Ethernet MEF Anomalies 24Hr current table." ::= { adGenMEF10100EthAnomaliesPerformance 3 } adGenMEF10100EthAnomalies24HrCurrentEntry OBJECT-TYPE SYNTAX AdGenMEF10100EthAnomalies24HrCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the 10/100 Ethernet MEF Anomalies 24Hr current table." INDEX { ifIndex } ::= { adGenMEF10100EthAnomalies24HrCurrentTable 1 } AdGenMEF10100EthAnomalies24HrCurrentEntry ::= SEQUENCE { adGenMEF10100EthAnomalies24HrCurrentFramesWithInvalidCEVLANID Gauge32 } adGenMEF10100EthAnomalies24HrCurrentFramesWithInvalidCEVLANID OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with invalid CE-VLAN id." ::= { adGenMEF10100EthAnomalies24HrCurrentEntry 1 } --================================================================================================================== adGenMEF10100EthAnomalies24HrIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEF10100EthAnomalies24HrIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The 10/100 Ethernet 24Hr interval table." ::= { adGenMEF10100EthAnomaliesPerformance 4 } adGenMEF10100EthAnomalies24HrIntervalEntry OBJECT-TYPE SYNTAX AdGenMEF10100EthAnomalies24HrIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the 10/100 Ethernet MEF Anomalies 24Hr interval table." INDEX { ifIndex, adGenMEF10100EthAnomalies24HrIntervalNumber } ::= { adGenMEF10100EthAnomalies24HrIntervalTable 1 } AdGenMEF10100EthAnomalies24HrIntervalEntry ::= SEQUENCE { adGenMEF10100EthAnomalies24HrIntervalNumber Integer32, adGenMEF10100EthAnomalies24HrIntervalFramesWithInvalidCEVLANID Gauge32 } adGenMEF10100EthAnomalies24HrIntervalNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 7, where 1 is the most recently completed day and 7 is the least recently completed day (assuming that all 7 days are valid)." ::= { adGenMEF10100EthAnomalies24HrIntervalEntry 1 } adGenMEF10100EthAnomalies24HrIntervalFramesWithInvalidCEVLANID OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with invalid CE-VLAN id in the selected day." ::= { adGenMEF10100EthAnomalies24HrIntervalEntry 2 } --================================================================================================================== adGenMEFGigEthAnomaliesPerformance OBJECT IDENTIFIER ::= { adGenMEFPerformance 2 } adGenMEFGigEthAnomalies15MinCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFGigEthAnomalies15MinCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Gigabit Ethernet MEF Anomalies 15Min current table." ::= { adGenMEFGigEthAnomaliesPerformance 1 } adGenMEFGigEthAnomalies15MinCurrentEntry OBJECT-TYPE SYNTAX AdGenMEFGigEthAnomalies15MinCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Gigabit Ethernet MEF Anomalies 15Min current table." INDEX { ifIndex } ::= { adGenMEFGigEthAnomalies15MinCurrentTable 1 } AdGenMEFGigEthAnomalies15MinCurrentEntry ::= SEQUENCE { adGenMEFGigEthAnomalies15MinCurrentFramesWithInvalidCEVLANID Gauge32 } adGenMEFGigEthAnomalies15MinCurrentFramesWithInvalidCEVLANID OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with invalid CE-VLAN id." ::= { adGenMEFGigEthAnomalies15MinCurrentEntry 1 } --================================================================================================================== adGenMEFGigEthAnomalies15MinIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFGigEthAnomalies15MinIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Gigabit Ethernet MEF Anomalies 15Min interval table." ::= { adGenMEFGigEthAnomaliesPerformance 2 } adGenMEFGigEthAnomalies15MinIntervalEntry OBJECT-TYPE SYNTAX AdGenMEFGigEthAnomalies15MinIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Gigabit Ethernet MEF Anomalies 15Min interval table." INDEX { ifIndex, adGenMEFGigEthAnomalies15MinIntervalNumber } ::= { adGenMEFGigEthAnomalies15MinIntervalTable 1 } AdGenMEFGigEthAnomalies15MinIntervalEntry ::= SEQUENCE { adGenMEFGigEthAnomalies15MinIntervalNumber Integer32, adGenMEFGigEthAnomalies15MinIntervalFramesWithInvalidCEVLANID Gauge32 } adGenMEFGigEthAnomalies15MinIntervalNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { adGenMEFGigEthAnomalies15MinIntervalEntry 1 } adGenMEFGigEthAnomalies15MinIntervalFramesWithInvalidCEVLANID OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with invalid CE-VLAN id." ::= { adGenMEFGigEthAnomalies15MinIntervalEntry 2 } --================================================================================================================== adGenMEFGigEthAnomalies24HrCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFGigEthAnomalies24HrCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Gigabit Ethernet MEF Anomalies 24Hr current table." ::= { adGenMEFGigEthAnomaliesPerformance 3 } adGenMEFGigEthAnomalies24HrCurrentEntry OBJECT-TYPE SYNTAX AdGenMEFGigEthAnomalies24HrCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Gigabit Ethernet MEF Anomalies 24Hr current table." INDEX { ifIndex } ::= { adGenMEFGigEthAnomalies24HrCurrentTable 1 } AdGenMEFGigEthAnomalies24HrCurrentEntry ::= SEQUENCE { adGenMEFGigEthAnomalies24HrCurrentFramesWithInvalidCEVLANID Gauge32 } adGenMEFGigEthAnomalies24HrCurrentFramesWithInvalidCEVLANID OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with invalid CE-VLAN id." ::= { adGenMEFGigEthAnomalies24HrCurrentEntry 1 } --================================================================================================================== adGenMEFGigEthAnomalies24HrIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFGigEthAnomalies24HrIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Gigabit Ethernet 24Hr interval table." ::= { adGenMEFGigEthAnomaliesPerformance 4 } adGenMEFGigEthAnomalies24HrIntervalEntry OBJECT-TYPE SYNTAX AdGenMEFGigEthAnomalies24HrIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Gigabit Ethernet MEF Anomalies 24Hr interval table." INDEX { ifIndex, adGenMEFGigEthAnomalies24HrIntervalNumber } ::= { adGenMEFGigEthAnomalies24HrIntervalTable 1 } AdGenMEFGigEthAnomalies24HrIntervalEntry ::= SEQUENCE { adGenMEFGigEthAnomalies24HrIntervalNumber Integer32, adGenMEFGigEthAnomalies24HrIntervalFramesWithInvalidCEVLANID Gauge32 } adGenMEFGigEthAnomalies24HrIntervalNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 7, where 1 is the most recently completed day and 7 is the least recently completed day (assuming that all 7 days are valid)." ::= { adGenMEFGigEthAnomalies24HrIntervalEntry 1 } adGenMEFGigEthAnomalies24HrIntervalFramesWithInvalidCEVLANID OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of received frames with invalid CE-VLAN id in the selected day." ::= { adGenMEFGigEthAnomalies24HrIntervalEntry 2 } --================================================================================================================== adGenMEFPolicerPerformance OBJECT IDENTIFIER ::= { adGenMEFPerformance 3 } adGenMEFPolicerPerformanceScalars OBJECT IDENTIFIER ::= { adGenMEFPolicerPerformance 1} adGenMEFPolicerRstCurrentIntervals OBJECT-TYPE SYNTAX INTEGER { ethRstAllCurrentIntervals(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset current interval MEF Traffic Management PM data on ALL policers." ::= { adGenMEFPolicerPerformanceScalars 1 } adGenMEFPolicerRstAll OBJECT-TYPE SYNTAX INTEGER { ethRstAll(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset MEF Traffic Management PM data on ALL policers." ::= { adGenMEFPolicerPerformanceScalars 2 } adGenMEFPolicer15MinCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFPolicer15MinCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The MEF Traffic Management 15Min current table." ::= { adGenMEFPolicerPerformance 2 } adGenMEFPolicer15MinCurrentEntry OBJECT-TYPE SYNTAX AdGenMEFPolicer15MinCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in MEF Traffic Management 15Min current table." INDEX { adGenMEFProfileIndex } ::= { adGenMEFPolicer15MinCurrentTable 1 } AdGenMEFPolicer15MinCurrentEntry ::= SEQUENCE { adGenMEFPolicer15MinCurrentIngressGreenFrames Gauge32, adGenMEFPolicer15MinCurrentIngressYellowFrames Gauge32, adGenMEFPolicer15MinCurrentIngressRedFrames Gauge32, adGenMEFPolicer15MinCurrentIngressGreenOctets Gauge32, adGenMEFPolicer15MinCurrentIngressYellowOctets Gauge32, adGenMEFPolicer15MinCurrentIngressRedOctets Gauge32, adGenMEFPolicer15MinCurrentCongDiscardsIngressGreenFrames Gauge32, adGenMEFPolicer15MinCurrentCongDiscardsIngressGreenOctets Gauge32, adGenMEFPolicer15MinCurrentCongDiscardsIngressYellowFrames Gauge32, adGenMEFPolicer15MinCurrentCongDiscardsIngressYellowOctets Gauge32, adGenMEFPolicer15MinCurrentHCIngressGreenFrames Counter64, adGenMEFPolicer15MinCurrentHCIngressYellowFrames Counter64, adGenMEFPolicer15MinCurrentHCIngressRedFrames Counter64, adGenMEFPolicer15MinCurrentHCIngressGreenOctets Counter64, adGenMEFPolicer15MinCurrentHCIngressYellowOctets Counter64, adGenMEFPolicer15MinCurrentHCIngressRedOctets Counter64, adGenMEFPolicer15MinCurrentHCCongDiscardsIngressGreenFrames Counter64, adGenMEFPolicer15MinCurrentHCCongDiscardsIngressGreenOctets Counter64, adGenMEFPolicer15MinCurrentHCCongDiscardsIngressYellowFrames Counter64, adGenMEFPolicer15MinCurrentHCCongDiscardsIngressYellowOctets Counter64 } adGenMEFPolicer15MinCurrentIngressGreenFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked green." ::= { adGenMEFPolicer15MinCurrentEntry 1 } adGenMEFPolicer15MinCurrentIngressYellowFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked yellow." ::= { adGenMEFPolicer15MinCurrentEntry 2 } adGenMEFPolicer15MinCurrentIngressRedFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked red (dropped)." ::= { adGenMEFPolicer15MinCurrentEntry 3 } adGenMEFPolicer15MinCurrentIngressGreenOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked green." ::= { adGenMEFPolicer15MinCurrentEntry 4 } adGenMEFPolicer15MinCurrentIngressYellowOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked yellow." ::= { adGenMEFPolicer15MinCurrentEntry 5 } adGenMEFPolicer15MinCurrentIngressRedOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked red (dropped)." ::= { adGenMEFPolicer15MinCurrentEntry 6 } adGenMEFPolicer15MinCurrentCongDiscardsIngressGreenFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of green frames discarded due to congestion in the egress queue." ::= { adGenMEFPolicer15MinCurrentEntry 7 } adGenMEFPolicer15MinCurrentCongDiscardsIngressGreenOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of green octets discarded due to congestion in the egress queue" ::= { adGenMEFPolicer15MinCurrentEntry 8 } adGenMEFPolicer15MinCurrentCongDiscardsIngressYellowFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of yellow frames discarded due to congestion in the egress queue" ::= { adGenMEFPolicer15MinCurrentEntry 9 } adGenMEFPolicer15MinCurrentCongDiscardsIngressYellowOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of yellow octets discarded due to congestion in the egress queue" ::= { adGenMEFPolicer15MinCurrentEntry 10 } adGenMEFPolicer15MinCurrentHCIngressGreenFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked green." ::= { adGenMEFPolicer15MinCurrentEntry 11 } adGenMEFPolicer15MinCurrentHCIngressYellowFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked yellow." ::= { adGenMEFPolicer15MinCurrentEntry 12 } adGenMEFPolicer15MinCurrentHCIngressRedFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked red (dropped)." ::= { adGenMEFPolicer15MinCurrentEntry 13 } adGenMEFPolicer15MinCurrentHCIngressGreenOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked green." ::= { adGenMEFPolicer15MinCurrentEntry 14 } adGenMEFPolicer15MinCurrentHCIngressYellowOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked yellow." ::= { adGenMEFPolicer15MinCurrentEntry 15 } adGenMEFPolicer15MinCurrentHCIngressRedOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked red (dropped)." ::= { adGenMEFPolicer15MinCurrentEntry 16 } adGenMEFPolicer15MinCurrentHCCongDiscardsIngressGreenFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of green frames discarded due to congestion in the egress queue." ::= { adGenMEFPolicer15MinCurrentEntry 17 } adGenMEFPolicer15MinCurrentHCCongDiscardsIngressGreenOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of green octets discarded due to congestion in the egress queue" ::= { adGenMEFPolicer15MinCurrentEntry 18 } adGenMEFPolicer15MinCurrentHCCongDiscardsIngressYellowFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of yellow frames discarded due to congestion in the egress queue" ::= { adGenMEFPolicer15MinCurrentEntry 19 } adGenMEFPolicer15MinCurrentHCCongDiscardsIngressYellowOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of yellow octets discarded due to congestion in the egress queue" ::= { adGenMEFPolicer15MinCurrentEntry 20 } --================================================================================================================== adGenMEFPolicer15MinIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFPolicer15MinIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The MEF Traffic Management 15Min interval table." ::= { adGenMEFPolicerPerformance 3 } adGenMEFPolicer15MinIntervalEntry OBJECT-TYPE SYNTAX AdGenMEFPolicer15MinIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in Traffic Management 15Min interval table." INDEX { adGenMEFProfileIndex, adGenMEFPolicer15MinIntervalNumber } ::= { adGenMEFPolicer15MinIntervalTable 1 } AdGenMEFPolicer15MinIntervalEntry ::= SEQUENCE { adGenMEFPolicer15MinIntervalNumber Integer32, adGenMEFPolicer15MinIntervalIngressGreenFrames Gauge32, adGenMEFPolicer15MinIntervalIngressYellowFrames Gauge32, adGenMEFPolicer15MinIntervalIngressRedFrames Gauge32, adGenMEFPolicer15MinIntervalIngressGreenOctets Gauge32, adGenMEFPolicer15MinIntervalIngressYellowOctets Gauge32, adGenMEFPolicer15MinIntervalIngressRedOctets Gauge32, adGenMEFPolicer15MinIntervalCongDiscardsIngressGreenFrames Gauge32, adGenMEFPolicer15MinIntervalCongDiscardsIngressGreenOctets Gauge32, adGenMEFPolicer15MinIntervalCongDiscardsIngressYellowFrames Gauge32, adGenMEFPolicer15MinIntervalCongDiscardsIngressYellowOctets Gauge32, adGenMEFPolicer15MinIntervalHCIngressGreenFrames Counter64, adGenMEFPolicer15MinIntervalHCIngressYellowFrames Counter64, adGenMEFPolicer15MinIntervalHCIngressRedFrames Counter64, adGenMEFPolicer15MinIntervalHCIngressGreenOctets Counter64, adGenMEFPolicer15MinIntervalHCIngressYellowOctets Counter64, adGenMEFPolicer15MinIntervalHCIngressRedOctets Counter64, adGenMEFPolicer15MinIntervalHCCongDiscardsIngressGreenFrames Counter64, adGenMEFPolicer15MinIntervalHCCongDiscardsIngressGreenOctets Counter64, adGenMEFPolicer15MinIntervalHCCongDiscardsIngressYellowFrames Counter64, adGenMEFPolicer15MinIntervalHCCongDiscardsIngressYellowOctets Counter64 } adGenMEFPolicer15MinIntervalNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { adGenMEFPolicer15MinIntervalEntry 1 } adGenMEFPolicer15MinIntervalIngressGreenFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked green in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 2 } adGenMEFPolicer15MinIntervalIngressYellowFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked yellow in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 3 } adGenMEFPolicer15MinIntervalIngressRedFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked red (dropped) in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 4 } adGenMEFPolicer15MinIntervalIngressGreenOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked green in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 5 } adGenMEFPolicer15MinIntervalIngressYellowOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked yellow in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 6 } adGenMEFPolicer15MinIntervalIngressRedOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked red (dropped) in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 7 } adGenMEFPolicer15MinIntervalCongDiscardsIngressGreenFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of green frames discarded due to congestion in the egress queue in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 8 } adGenMEFPolicer15MinIntervalCongDiscardsIngressGreenOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of green octets discarded due to congestion in the egress queue in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 9 } adGenMEFPolicer15MinIntervalCongDiscardsIngressYellowFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of yellow frames discarded due to congestion in the egress queue in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 10 } adGenMEFPolicer15MinIntervalCongDiscardsIngressYellowOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of yellow octets discarded due to congestion in the egress queue in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 11 } adGenMEFPolicer15MinIntervalHCIngressGreenFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked green in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 12 } adGenMEFPolicer15MinIntervalHCIngressYellowFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked yellow in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 13 } adGenMEFPolicer15MinIntervalHCIngressRedFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked red (dropped) in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 14 } adGenMEFPolicer15MinIntervalHCIngressGreenOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked green in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 15 } adGenMEFPolicer15MinIntervalHCIngressYellowOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked yellow in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 16 } adGenMEFPolicer15MinIntervalHCIngressRedOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked red (dropped) in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 17 } adGenMEFPolicer15MinIntervalHCCongDiscardsIngressGreenFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of green frames discarded due to congestion in the egress queue in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 18 } adGenMEFPolicer15MinIntervalHCCongDiscardsIngressGreenOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of green octets discarded due to congestion in the egress queue in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 19 } adGenMEFPolicer15MinIntervalHCCongDiscardsIngressYellowFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of yellow frames discarded due to congestion in the egress queue in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 20 } adGenMEFPolicer15MinIntervalHCCongDiscardsIngressYellowOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of yellow octets discarded due to congestion in the egress queue in the selected interval." ::= { adGenMEFPolicer15MinIntervalEntry 21 } --================================================================================================================== adGenMEFPolicer24HrCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFPolicer24HrCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The MEF Traffic Management 24Hr current table." ::= { adGenMEFPolicerPerformance 4 } adGenMEFPolicer24HrCurrentEntry OBJECT-TYPE SYNTAX AdGenMEFPolicer24HrCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in MEF Traffic Management 24Hr current table." INDEX { adGenMEFProfileIndex } ::= { adGenMEFPolicer24HrCurrentTable 1 } AdGenMEFPolicer24HrCurrentEntry ::= SEQUENCE { adGenMEFPolicer24HrCurrentIngressGreenFrames Gauge32, adGenMEFPolicer24HrCurrentIngressYellowFrames Gauge32, adGenMEFPolicer24HrCurrentIngressRedFrames Gauge32, adGenMEFPolicer24HrCurrentIngressGreenOctets Gauge32, adGenMEFPolicer24HrCurrentIngressYellowOctets Gauge32, adGenMEFPolicer24HrCurrentIngressRedOctets Gauge32, adGenMEFPolicer24HrCurrentCongDiscardsIngressGreenFrames Gauge32, adGenMEFPolicer24HrCurrentCongDiscardsIngressGreenOctets Gauge32, adGenMEFPolicer24HrCurrentCongDiscardsIngressYellowFrames Gauge32, adGenMEFPolicer24HrCurrentCongDiscardsIngressYellowOctets Gauge32, adGenMEFPolicer24HrCurrentHCIngressGreenFrames Counter64, adGenMEFPolicer24HrCurrentHCIngressYellowFrames Counter64, adGenMEFPolicer24HrCurrentHCIngressRedFrames Counter64, adGenMEFPolicer24HrCurrentHCIngressGreenOctets Counter64, adGenMEFPolicer24HrCurrentHCIngressYellowOctets Counter64, adGenMEFPolicer24HrCurrentHCIngressRedOctets Counter64, adGenMEFPolicer24HrCurrentHCCongDiscardsIngressGreenFrames Counter64, adGenMEFPolicer24HrCurrentHCCongDiscardsIngressGreenOctets Counter64, adGenMEFPolicer24HrCurrentHCCongDiscardsIngressYellowFrames Counter64, adGenMEFPolicer24HrCurrentHCCongDiscardsIngressYellowOctets Counter64 } adGenMEFPolicer24HrCurrentIngressGreenFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked green." ::= { adGenMEFPolicer24HrCurrentEntry 1 } adGenMEFPolicer24HrCurrentIngressYellowFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked yellow." ::= { adGenMEFPolicer24HrCurrentEntry 2 } adGenMEFPolicer24HrCurrentIngressRedFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked red (dropped)." ::= { adGenMEFPolicer24HrCurrentEntry 3 } adGenMEFPolicer24HrCurrentIngressGreenOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked green." ::= { adGenMEFPolicer24HrCurrentEntry 4 } adGenMEFPolicer24HrCurrentIngressYellowOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked yellow." ::= { adGenMEFPolicer24HrCurrentEntry 5 } adGenMEFPolicer24HrCurrentIngressRedOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked red (dropped)." ::= { adGenMEFPolicer24HrCurrentEntry 6 } adGenMEFPolicer24HrCurrentCongDiscardsIngressGreenFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of green frames discarded due to congestion in the egress queue." ::= { adGenMEFPolicer24HrCurrentEntry 7 } adGenMEFPolicer24HrCurrentCongDiscardsIngressGreenOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of green octets discarded due to congestion in the egress queue." ::= { adGenMEFPolicer24HrCurrentEntry 8 } adGenMEFPolicer24HrCurrentCongDiscardsIngressYellowFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of yellow frames discarded due to congestion in the egress queue." ::= { adGenMEFPolicer24HrCurrentEntry 9 } adGenMEFPolicer24HrCurrentCongDiscardsIngressYellowOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of yellow octets discarded due to congestion in the egress queue." ::= { adGenMEFPolicer24HrCurrentEntry 10 } adGenMEFPolicer24HrCurrentHCIngressGreenFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked green." ::= { adGenMEFPolicer24HrCurrentEntry 11 } adGenMEFPolicer24HrCurrentHCIngressYellowFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked yellow." ::= { adGenMEFPolicer24HrCurrentEntry 12 } adGenMEFPolicer24HrCurrentHCIngressRedFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked red (dropped)." ::= { adGenMEFPolicer24HrCurrentEntry 13 } adGenMEFPolicer24HrCurrentHCIngressGreenOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked green." ::= { adGenMEFPolicer24HrCurrentEntry 14 } adGenMEFPolicer24HrCurrentHCIngressYellowOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked yellow." ::= { adGenMEFPolicer24HrCurrentEntry 15 } adGenMEFPolicer24HrCurrentHCIngressRedOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked red (dropped)." ::= { adGenMEFPolicer24HrCurrentEntry 16 } adGenMEFPolicer24HrCurrentHCCongDiscardsIngressGreenFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of green frames discarded due to congestion in the egress queue." ::= { adGenMEFPolicer24HrCurrentEntry 17 } adGenMEFPolicer24HrCurrentHCCongDiscardsIngressGreenOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of green octets discarded due to congestion in the egress queue." ::= { adGenMEFPolicer24HrCurrentEntry 18 } adGenMEFPolicer24HrCurrentHCCongDiscardsIngressYellowFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of yellow frames discarded due to congestion in the egress queue." ::= { adGenMEFPolicer24HrCurrentEntry 19 } adGenMEFPolicer24HrCurrentHCCongDiscardsIngressYellowOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of yellow octets discarded due to congestion in the egress queue." ::= { adGenMEFPolicer24HrCurrentEntry 20 } --================================================================================================================== adGenMEFPolicer24HrIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFPolicer24HrIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The MEF Traffic Management 24Hr interval table." ::= { adGenMEFPolicerPerformance 5 } adGenMEFPolicer24HrIntervalEntry OBJECT-TYPE SYNTAX AdGenMEFPolicer24HrIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in Traffic Management 24Hr interval table." INDEX { adGenMEFProfileIndex, adGenMEFPolicer24HrIntervalNumber } ::= { adGenMEFPolicer24HrIntervalTable 1 } AdGenMEFPolicer24HrIntervalEntry ::= SEQUENCE { adGenMEFPolicer24HrIntervalNumber Integer32, adGenMEFPolicer24HrIntervalIngressGreenFrames Gauge32, adGenMEFPolicer24HrIntervalIngressYellowFrames Gauge32, adGenMEFPolicer24HrIntervalIngressRedFrames Gauge32, adGenMEFPolicer24HrIntervalIngressGreenOctets Gauge32, adGenMEFPolicer24HrIntervalIngressYellowOctets Gauge32, adGenMEFPolicer24HrIntervalIngressRedOctets Gauge32, adGenMEFPolicer24HrIntervalCongDiscardsIngressGreenFrames Gauge32, adGenMEFPolicer24HrIntervalCongDiscardsIngressGreenOctets Gauge32, adGenMEFPolicer24HrIntervalCongDiscardsIngressYellowFrames Gauge32, adGenMEFPolicer24HrIntervalCongDiscardsIngressYellowOctets Gauge32, adGenMEFPolicer24HrIntervalHCIngressGreenFrames Counter64, adGenMEFPolicer24HrIntervalHCIngressYellowFrames Counter64, adGenMEFPolicer24HrIntervalHCIngressRedFrames Counter64, adGenMEFPolicer24HrIntervalHCIngressGreenOctets Counter64, adGenMEFPolicer24HrIntervalHCIngressYellowOctets Counter64, adGenMEFPolicer24HrIntervalHCIngressRedOctets Counter64, adGenMEFPolicer24HrIntervalHCCongDiscardsIngressGreenFrames Counter64, adGenMEFPolicer24HrIntervalHCCongDiscardsIngressGreenOctets Counter64, adGenMEFPolicer24HrIntervalHCCongDiscardsIngressYellowFrames Counter64, adGenMEFPolicer24HrIntervalHCCongDiscardsIngressYellowOctets Counter64 } adGenMEFPolicer24HrIntervalNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A number between 1 and 7, where 1 is the most recently completed day and 7 is the least recently completed day (assuming that all 7 days are valid)." ::= { adGenMEFPolicer24HrIntervalEntry 1 } adGenMEFPolicer24HrIntervalIngressGreenFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked green in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 2 } adGenMEFPolicer24HrIntervalIngressYellowFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked yellow in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 3 } adGenMEFPolicer24HrIntervalIngressRedFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked red (dropped) in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 4 } adGenMEFPolicer24HrIntervalIngressGreenOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked green in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 5 } adGenMEFPolicer24HrIntervalIngressYellowOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked yellow in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 6 } adGenMEFPolicer24HrIntervalIngressRedOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked red (dropped) in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 7 } adGenMEFPolicer24HrIntervalCongDiscardsIngressGreenFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of green frames discarded due to congestion in the egress queue in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 8 } adGenMEFPolicer24HrIntervalCongDiscardsIngressGreenOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of green octets discarded due to congestion in the egress queue in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 9 } adGenMEFPolicer24HrIntervalCongDiscardsIngressYellowFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of yellow frames discarded due to congestion in the egress queue in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 10 } adGenMEFPolicer24HrIntervalCongDiscardsIngressYellowOctets OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of yellow octets discarded due to congestion in the egress queue in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 11 } adGenMEFPolicer24HrIntervalHCIngressGreenFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked green in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 12 } adGenMEFPolicer24HrIntervalHCIngressYellowFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked yellow in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 13 } adGenMEFPolicer24HrIntervalHCIngressRedFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number frames coming out of the ingress policer which is marked red (dropped) in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 14 } adGenMEFPolicer24HrIntervalHCIngressGreenOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked green in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 15 } adGenMEFPolicer24HrIntervalHCIngressYellowOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked yellow in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 16 } adGenMEFPolicer24HrIntervalHCIngressRedOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number octets coming out of the ingress policer which is marked red (dropped) in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 17 } adGenMEFPolicer24HrIntervalHCCongDiscardsIngressGreenFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of green frames discarded due to congestion in the egress queue in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 18 } adGenMEFPolicer24HrIntervalHCCongDiscardsIngressGreenOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of green octets discarded due to congestion in the egress queue in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 19 } adGenMEFPolicer24HrIntervalHCCongDiscardsIngressYellowFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of yellow frames discarded due to congestion in the egress queue in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 20 } adGenMEFPolicer24HrIntervalHCCongDiscardsIngressYellowOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter associated with the number of yellow octets discarded due to congestion in the egress queue in the selected interval." ::= { adGenMEFPolicer24HrIntervalEntry 21 } --================================================================================================================== adGenMEFPolicerPerfResetTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFPolicerPerfResetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Policer Performance Reset table." ::= { adGenMEFPolicerPerformance 6 } adGenMEFPolicerPerfResetEntry OBJECT-TYPE SYNTAX AdGenMEFPolicerPerfResetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Policer Performance Reset table." INDEX { adGenMEFProfileIndex } ::= { adGenMEFPolicerPerfResetTable 1 } AdGenMEFPolicerPerfResetEntry ::= SEQUENCE { adGenMEFPolicerPerfReset INTEGER } adGenMEFPolicerPerfReset OBJECT-TYPE SYNTAX INTEGER { policerPerfRst(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Resets all performance history for the selected policer." ::= { adGenMEFPolicerPerfResetEntry 1 } --================================================================================================================== adGenMEF10100EthAnomaliesPerfThresholds OBJECT IDENTIFIER ::= { adGenMEFPerformance 4 } adGenMEF10100EthAnomalies15MinThreshTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEF10100EthAnomalies15MinThreshEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The 10/100 Ethernet MEF Anomalies 15 minute threshold table." ::= { adGenMEF10100EthAnomaliesPerfThresholds 1 } adGenMEF10100EthAnomalies15MinThreshEntry OBJECT-TYPE SYNTAX AdGenMEF10100EthAnomalies15MinThreshEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the 10/100 Ethernet MEF Anomalies 15 minute threshold table." INDEX { ifIndex } ::= { adGenMEF10100EthAnomalies15MinThreshTable 1 } AdGenMEF10100EthAnomalies15MinThreshEntry ::= SEQUENCE { adGenMEF10100EthAnomalies15MinThreshFramesWithInvalidCEVLANID Gauge32 } adGenMEF10100EthAnomalies15MinThreshFramesWithInvalidCEVLANID OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The 15 minute threshold associated with the number of received frames with invalid CE-VLAN id." ::= { adGenMEF10100EthAnomalies15MinThreshEntry 1 } --================================================================================================================== adGenMEF10100EthAnomalies24HrThreshTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEF10100EthAnomalies24HrThreshEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The 10/100 Ethernet MEF Anomalies 24 hour threshold table." ::= { adGenMEF10100EthAnomaliesPerfThresholds 2 } adGenMEF10100EthAnomalies24HrThreshEntry OBJECT-TYPE SYNTAX AdGenMEF10100EthAnomalies24HrThreshEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the 10/100 Ethernet MEF Anomalies 24 hour threshold table." INDEX { ifIndex } ::= { adGenMEF10100EthAnomalies24HrThreshTable 1 } AdGenMEF10100EthAnomalies24HrThreshEntry ::= SEQUENCE { adGenMEF10100EthAnomalies24HrThreshFramesWithInvalidCEVLANID Gauge32 } adGenMEF10100EthAnomalies24HrThreshFramesWithInvalidCEVLANID OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The 24 hour threshold associated with the number of received frames with invalid CE-VLAN id." ::= { adGenMEF10100EthAnomalies24HrThreshEntry 1 } --================================================================================================================== adGenMEFGigEthAnomaliesPerfThresholds OBJECT IDENTIFIER ::= { adGenMEFPerformance 5 } adGenMEFGigEthAnomalies15MinThreshTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFGigEthAnomalies15MinThreshEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Gigabit Ethernet MEF Anomalies 15 minute threshold table." ::= { adGenMEFGigEthAnomaliesPerfThresholds 1 } adGenMEFGigEthAnomalies15MinThreshEntry OBJECT-TYPE SYNTAX AdGenMEFGigEthAnomalies15MinThreshEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Gigabit Ethernet MEF Anomalies 15 minute threshold table." INDEX { ifIndex } ::= { adGenMEFGigEthAnomalies15MinThreshTable 1 } AdGenMEFGigEthAnomalies15MinThreshEntry ::= SEQUENCE { adGenMEFGigEthAnomalies15MinThreshFramesWithInvalidCEVLANID Gauge32 } adGenMEFGigEthAnomalies15MinThreshFramesWithInvalidCEVLANID OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The 15 minute threshold associated with the number of received frames with invalid CE-VLAN id." ::= { adGenMEFGigEthAnomalies15MinThreshEntry 1 } --================================================================================================================== adGenMEFGigEthAnomalies24HrThreshTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFGigEthAnomalies24HrThreshEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Gigabit Ethernet MEF Anomalies 24 hour threshold table." ::= { adGenMEFGigEthAnomaliesPerfThresholds 2 } adGenMEFGigEthAnomalies24HrThreshEntry OBJECT-TYPE SYNTAX AdGenMEFGigEthAnomalies24HrThreshEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Gigabit Ethernet MEF Anomalies 24 hour threshold table." INDEX { ifIndex } ::= { adGenMEFGigEthAnomalies24HrThreshTable 1 } AdGenMEFGigEthAnomalies24HrThreshEntry ::= SEQUENCE { adGenMEFGigEthAnomalies24HrThreshFramesWithInvalidCEVLANID Gauge32 } adGenMEFGigEthAnomalies24HrThreshFramesWithInvalidCEVLANID OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The 24 hour threshold associated with the number of received frames with invalid CE-VLAN id." ::= { adGenMEFGigEthAnomalies24HrThreshEntry 1 } --================================================================================================================== adGenMEFPolicerPerfThresholds OBJECT IDENTIFIER ::= { adGenMEFPerformance 6 } adGenMEFPolicer15MinThreshTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFPolicer15MinThreshEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The MEF Traffic Management 15 minute threshold table." ::= { adGenMEFPolicerPerfThresholds 1 } adGenMEFPolicer15MinThreshEntry OBJECT-TYPE SYNTAX AdGenMEFPolicer15MinThreshEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the MEF Traffic Management 15 minute threshold table." INDEX { adGenMEFProfileIndex } ::= { adGenMEFPolicer15MinThreshTable 1 } AdGenMEFPolicer15MinThreshEntry ::= SEQUENCE { adGenMEFPolicer15MinThresholdIngressGreenFrames Gauge32, adGenMEFPolicer15MinThresholdIngressYellowFrames Gauge32, adGenMEFPolicer15MinThresholdIngressRedFrames Gauge32, adGenMEFPolicer15MinThresholdCongDiscardsIngressGreenFrames Gauge32, adGenMEFPolicer15MinThresholdCongDiscardsIngressYellowFrames Gauge32, adGenMEFPolicer15MinThresholdHCIngressGreenFrames Unsigned64TC, adGenMEFPolicer15MinThresholdHCIngressYellowFrames Unsigned64TC, adGenMEFPolicer15MinThresholdHCIngressRedFrames Unsigned64TC, adGenMEFPolicer15MinThresholdHCCongDiscardsIngressGreenFrames Unsigned64TC, adGenMEFPolicer15MinThresholdHCCongDiscardsIngressYellowFrames Unsigned64TC } adGenMEFPolicer15MinThresholdIngressGreenFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The 15 minute threshold associated with the number frames coming out of the ingress policer which is marked green. A value of 0 will disable the Threshold. If the adGenMEFPolicer15MinThresholdHCIngressGreenFrames is set to a value greater than 2^32, then this oid will be forced to a 0." ::= { adGenMEFPolicer15MinThreshEntry 1 } adGenMEFPolicer15MinThresholdIngressYellowFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The 15 minute threshold associated with the number frames coming out of the ingress policer which is marked yellow. A value of 0 will disable the Threshold. If the adGenMEFPolicer15MinThresholdHCIngressYellowFrames is set to a value greater than 2^32, then this oid will be forced to a 0." ::= { adGenMEFPolicer15MinThreshEntry 2 } adGenMEFPolicer15MinThresholdIngressRedFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The 15 minute threshold associated with the number frames coming out of the ingress policer which is marked red (dropped). A value of 0 will disable the Threshold. If the adGenMEFPolicer15MinThresholdHCIngressRedFrames is set to a value greater than 2^32, then this oid will be forced to a 0." ::= { adGenMEFPolicer15MinThreshEntry 3 } adGenMEFPolicer15MinThresholdCongDiscardsIngressGreenFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The 15 minute threshold associated with the number of green frames discarded due to congestion in the egress queue. A value of 0 will disable the Threshold. If the adGenMEFPolicer15MinThresholdHCCongDiscardsIngressGreenFrames is set to a value greater than 2^32, then this oid will be forced to a 0." ::= { adGenMEFPolicer15MinThreshEntry 4 } adGenMEFPolicer15MinThresholdCongDiscardsIngressYellowFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The 15 minute threshold associated with the number of yellow frames discarded due to congestion in the egress queue. A value of 0 will disable the Threshold. If the adGenMEFPolicer15MinThresholdHCCongDiscardsIngressYellowFrames is set to a value greater than 2^32, then this oid will be forced to a 0." ::= { adGenMEFPolicer15MinThreshEntry 5 } adGenMEFPolicer15MinThresholdHCIngressGreenFrames OBJECT-TYPE SYNTAX Unsigned64TC MAX-ACCESS read-write STATUS current DESCRIPTION "The 15 minute threshold associated with the number frames coming out of the ingress policer which is marked green. A value of 0 will disable the Threshold. If this oid is set to a value greater than 2^32, then adGenMEFPolicer15MinThresholdIngressGreenFrames oid will be forced to a 0." ::= { adGenMEFPolicer15MinThreshEntry 6 } adGenMEFPolicer15MinThresholdHCIngressYellowFrames OBJECT-TYPE SYNTAX Unsigned64TC MAX-ACCESS read-write STATUS current DESCRIPTION "The 15 minute threshold associated with the number frames coming out of the ingress policer which is marked yellow. A value of 0 will disable the Threshold. If this oid is set to a value greater than 2^32, then adGenMEFPolicer15MinThresholdIngressYellowFrames oid will be forced to a 0." ::= { adGenMEFPolicer15MinThreshEntry 7 } adGenMEFPolicer15MinThresholdHCIngressRedFrames OBJECT-TYPE SYNTAX Unsigned64TC MAX-ACCESS read-write STATUS current DESCRIPTION "The 15 minute threshold associated with the number frames coming out of the ingress policer which is marked red (dropped). A value of 0 will disable the Threshold. If this oid is set to a value greater than 2^32, then adGenMEFPolicer15MinThresholdIngressRedFrames oid will be forced to a 0." ::= { adGenMEFPolicer15MinThreshEntry 8 } adGenMEFPolicer15MinThresholdHCCongDiscardsIngressGreenFrames OBJECT-TYPE SYNTAX Unsigned64TC MAX-ACCESS read-write STATUS current DESCRIPTION "The 15 minute threshold associated with the number of green frames discarded due to congestion in the egress queue. A value of 0 will disable the Threshold. If this oid is set to a value greater than 2^32, then adGenMEFPolicer15MinThresholdCongDiscardsIngressGreenFrames oid will be forced to a 0." ::= { adGenMEFPolicer15MinThreshEntry 9 } adGenMEFPolicer15MinThresholdHCCongDiscardsIngressYellowFrames OBJECT-TYPE SYNTAX Unsigned64TC MAX-ACCESS read-write STATUS current DESCRIPTION "The 15 minute threshold associated with the number of yellow frames discarded due to congestion in the egress queue. A value of 0 will disable the Threshold. If this oid is set to a value greater than 2^32, then adGenMEFPolicer15MinThresholdCongDiscardsIngressYellowFrames oid will be forced to a 0." ::= { adGenMEFPolicer15MinThreshEntry 10 } --================================================================================================================== adGenMEFPolicer24HrThreshTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenMEFPolicer24HrThreshEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The MEF Traffic Management 24 hour threshold table." ::= { adGenMEFPolicerPerfThresholds 2 } adGenMEFPolicer24HrThreshEntry OBJECT-TYPE SYNTAX AdGenMEFPolicer24HrThreshEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the MEF Traffic Management 24 hour threshold table." INDEX { adGenMEFProfileIndex } ::= { adGenMEFPolicer24HrThreshTable 1 } AdGenMEFPolicer24HrThreshEntry ::= SEQUENCE { adGenMEFPolicer24HrThresholdIngressGreenFrames Gauge32, adGenMEFPolicer24HrThresholdIngressYellowFrames Gauge32, adGenMEFPolicer24HrThresholdIngressRedFrames Gauge32, adGenMEFPolicer24HrThresholdCongDiscardsIngressGreenFrames Gauge32, adGenMEFPolicer24HrThresholdCongDiscardsIngressYellowFrames Gauge32, adGenMEFPolicer24HrThresholdHCIngressGreenFrames Unsigned64TC, adGenMEFPolicer24HrThresholdHCIngressYellowFrames Unsigned64TC, adGenMEFPolicer24HrThresholdHCIngressRedFrames Unsigned64TC, adGenMEFPolicer24HrThresholdHCCongDiscardsIngressGreenFrames Unsigned64TC, adGenMEFPolicer24HrThresholdHCCongDiscardsIngressYellowFrames Unsigned64TC } adGenMEFPolicer24HrThresholdIngressGreenFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The 24 hour threshold associated with the number frames coming out of the ingress policer which is marked green. A value of 0 will disable the Threshold. If the adGenMEFPolicer24HrThresholdHCIngressGreenFrames is set to a value greater than 2^32, then this oid will be forced to a 0." ::= { adGenMEFPolicer24HrThreshEntry 1 } adGenMEFPolicer24HrThresholdIngressYellowFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The 24 hour threshold associated with the number frames coming out of the ingress policer which is marked yellow. A value of 0 will disable the Threshold. If the adGenMEFPolicer24HrThresholdHCIngressYellowFrames is set to a value greater than 2^32, then this oid will be forced to a 0." ::= { adGenMEFPolicer24HrThreshEntry 2 } adGenMEFPolicer24HrThresholdIngressRedFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The 24 hour threshold associated with the number frames coming out of the ingress policer which is marked red (dropped). A value of 0 will disable the Threshold. If the adGenMEFPolicer24HrThresholdHCIngressRedFrames is set to a value greater than 2^32, then this oid will be forced to a 0." ::= { adGenMEFPolicer24HrThreshEntry 3 } adGenMEFPolicer24HrThresholdCongDiscardsIngressGreenFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The 24 hour threshold associated with the number of green frames discarded due to congestion in the egress queue. A value of 0 will disable the Threshold. If the adGenMEFPolicer24HrThresholdHCCongDiscardsIngressGreenFrames is set to a value greater than 2^32, then this oid will be forced to a 0." ::= { adGenMEFPolicer24HrThreshEntry 4 } adGenMEFPolicer24HrThresholdCongDiscardsIngressYellowFrames OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "The 24 hour threshold associated with the number of yellow frames discarded due to congestion in the egress queue. A value of 0 will disable the Threshold. If the adGenMEFPolicer24HrThresholdHCCongDiscardsIngressYellowFrames is set to a value greater than 2^32, then this oid will be forced to a 0." ::= { adGenMEFPolicer24HrThreshEntry 5 } adGenMEFPolicer24HrThresholdHCIngressGreenFrames OBJECT-TYPE SYNTAX Unsigned64TC MAX-ACCESS read-write STATUS current DESCRIPTION "The 24 hour threshold associated with the number frames coming out of the ingress policer which is marked green. A value of 0 will disable the Threshold. If this oid is set to a value greater than 2^32, then adGenMEFPolicer24HrThresholdIngressGreenFrames oid will be forced to a 0." ::= { adGenMEFPolicer24HrThreshEntry 6 } adGenMEFPolicer24HrThresholdHCIngressYellowFrames OBJECT-TYPE SYNTAX Unsigned64TC MAX-ACCESS read-write STATUS current DESCRIPTION "The 24 hour threshold associated with the number frames coming out of the ingress policer which is marked yellow. A value of 0 will disable the Threshold. If this oid is set to a value greater than 2^32, then adGenMEFPolicer24HrThresholdIngressYellowFrames oid will be forced to a 0." ::= { adGenMEFPolicer24HrThreshEntry 7 } adGenMEFPolicer24HrThresholdHCIngressRedFrames OBJECT-TYPE SYNTAX Unsigned64TC MAX-ACCESS read-write STATUS current DESCRIPTION "The 24 hour threshold associated with the number frames coming out of the ingress policer which is marked red (dropped). A value of 0 will disable the Threshold. If this oid is set to a value greater than 2^32, then adGenMEFPolicer24HrThresholdIngressRedFrames oid will be forced to a 0." ::= { adGenMEFPolicer24HrThreshEntry 8 } adGenMEFPolicer24HrThresholdHCCongDiscardsIngressGreenFrames OBJECT-TYPE SYNTAX Unsigned64TC MAX-ACCESS read-write STATUS current DESCRIPTION "The 24 hour threshold associated with the number of green frames discarded due to congestion in the egress queue. A value of 0 will disable the Threshold. If this oid is set to a value greater than 2^32, then adGenMEFPolicer24HrThresholdCongDiscardsIngressGreenFrames oid will be forced to a 0." ::= { adGenMEFPolicer24HrThreshEntry 9 } adGenMEFPolicer24HrThresholdHCCongDiscardsIngressYellowFrames OBJECT-TYPE SYNTAX Unsigned64TC MAX-ACCESS read-write STATUS current DESCRIPTION "The 24 hour threshold associated with the number of yellow frames discarded due to congestion in the egress queue. A value of 0 will disable the Threshold. If this oid is set to a value greater than 2^32, then adGenMEFPolicer24HrThresholdCongDiscardsIngressYellowFrames oid will be forced to a 0." ::= { adGenMEFPolicer24HrThreshEntry 10 } --================================================================================================================== -- ****************************************************************************************** -- Alarms -- ****************************************************************************************** adGenMEFSet10100EthAnomalies15MinFramesWithInvalidCEVLANID NOTIFICATION-TYPE OBJECTS { sysName, adGenPortTrapIdentifier, ifIndex } STATUS current DESCRIPTION "This trap indicates that the Ethernet port has crossed the 15 min Frames with Invalid CE-VLAN ID Threshold" --#TYPE "Status - Alarm" --#SUMMARY "MEF 2: 10/100 Ethernet Frames with Invalid CE-VLAN ID 15 min Threshold Crossed." --#SEVERITY WARNING --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adGenMEFEvents 1 } adGenMEFSet10100EthAnomalies24HrFramesWithInvalidCEVLANID NOTIFICATION-TYPE OBJECTS { sysName, adGenPortTrapIdentifier, ifIndex } STATUS current DESCRIPTION "This trap indicates that the Ethernet port has crossed the 24 hour Frames with Invalid CE-VLAN ID Threshold" --#TYPE "Status - Alarm" --#SUMMARY "MEF 3: 10/100 Ethernet Frames with Invalid CE-VLAN ID 24 hr Threshold Crossed." --#SEVERITY WARNING --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adGenMEFEvents 2 } adGenMEFSetGigEthAnomalies15MinFramesWithInvalidCEVLANID NOTIFICATION-TYPE OBJECTS { sysName, adGenPortTrapIdentifier, ifIndex } STATUS current DESCRIPTION "This trap indicates that the Gigabit Ethernet port has crossed the 15 min Frames with Invalid CE-VLAN ID Threshold" --#TYPE "Status - Alarm" --#SUMMARY "MEF 4: Gigabit Ethernet Frames with Invalid CE-VLAN ID 15 min Threshold Crossed." --#SEVERITY WARNING --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adGenMEFEvents 3 } adGenMEFSetGigEthAnomalies24HrFramesWithInvalidCEVLANID NOTIFICATION-TYPE OBJECTS { sysName, adGenPortTrapIdentifier, ifIndex } STATUS current DESCRIPTION "This trap indicates that the Gigabit Ethernet port has crossed the 24 hour Frames with Invalid CE-VLAN ID Threshold" --#TYPE "Status - Alarm" --#SUMMARY "MEF 5: Gigabit Ethernet Frames with Invalid CE-VLAN ID 24 hour Threshold Crossed." --#SEVERITY WARNING --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adGenMEFEvents 4 } adGenMEFSetPolicer15MinIngressGreenFrames NOTIFICATION-TYPE OBJECTS { sysName, adGenMEFProfileAlias, adGenMEFProfileIndex } STATUS current DESCRIPTION "This trap indicates that the specified policer has crossed the 15 minute Ingress Green Frames Threshold" --#TYPE "Status - Alarm" --#SUMMARY "MEF 6: Ingress Green Frames 15 min Threshold Crossed." --#SEVERITY WARNING --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adGenMEFEvents 5 } adGenMEFSetPolicer15MinIngressYellowFrames NOTIFICATION-TYPE OBJECTS { sysName, adGenMEFProfileAlias, adGenMEFProfileIndex } STATUS current DESCRIPTION "This trap indicates that the specified policer has crossed the 15 minute Ingress Yellow Frames Threshold" --#TYPE "Status - Alarm" --#SUMMARY "MEF 6: Ingress Yellow Frames 15 min Threshold Crossed." --#SEVERITY WARNING --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adGenMEFEvents 6 } adGenMEFSetPolicer15MinIngressRedFrames NOTIFICATION-TYPE OBJECTS { sysName, adGenMEFProfileAlias, adGenMEFProfileIndex } STATUS current DESCRIPTION "This trap indicates that the specified policer has crossed the 15 minute Ingress Red Frames Threshold" --#TYPE "Status - Alarm" --#SUMMARY "MEF 6: Ingress Red Frames 15 min Threshold Crossed." --#SEVERITY WARNING --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adGenMEFEvents 7 } adGenMEFSetPolicer15MinCongDiscardsIngressGreenFrames NOTIFICATION-TYPE OBJECTS { sysName, adGenMEFProfileAlias, adGenMEFProfileIndex } STATUS current DESCRIPTION "This trap indicates that the specified policer has crossed the 15 minute Congestion Discards Ingress Green Frames Threshold" --#TYPE "Status - Alarm" --#SUMMARY "MEF 6: Congestion Discards Ingress Green Frames 15 min Threshold Crossed." --#SEVERITY WARNING --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adGenMEFEvents 8 } adGenMEFSetPolicer15MinCongDiscardsIngressYellowFrames NOTIFICATION-TYPE OBJECTS { sysName, adGenMEFProfileAlias, adGenMEFProfileIndex } STATUS current DESCRIPTION "This trap indicates that the specified policer has crossed the 15 minute Congestion Discards Ingress Yellow Frames Threshold" --#TYPE "Status - Alarm" --#SUMMARY "MEF 6: Congestion Discards Ingress Yellow Frames 15 min Threshold Crossed." --#SEVERITY WARNING --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adGenMEFEvents 9 } adGenMEFSetPolicer24HrIngressGreenFrames NOTIFICATION-TYPE OBJECTS { sysName, adGenMEFProfileAlias, adGenMEFProfileIndex } STATUS current DESCRIPTION "This trap indicates that the specified policer has crossed the 24 hour Ingress Green Frames Threshold" --#TYPE "Status - Alarm" --#SUMMARY "MEF 6: Ingress Green Frames 24 hour Threshold Crossed." --#SEVERITY WARNING --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adGenMEFEvents 10 } adGenMEFSetPolicer24HrIngressYellowFrames NOTIFICATION-TYPE OBJECTS { sysName, adGenMEFProfileAlias, adGenMEFProfileIndex } STATUS current DESCRIPTION "This trap indicates that the specified policer has crossed the 24 hour Ingress Yellow Frames Threshold" --#TYPE "Status - Alarm" --#SUMMARY "MEF 6: Ingress Yellow Frames 24 hour Threshold Crossed." --#SEVERITY WARNING --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adGenMEFEvents 11 } adGenMEFSetPolicer24HrIngressRedFrames NOTIFICATION-TYPE OBJECTS { sysName, adGenMEFProfileAlias, adGenMEFProfileIndex } STATUS current DESCRIPTION "This trap indicates that the specified policer has crossed the 24 hour Ingress Red Frames Threshold" --#TYPE "Status - Alarm" --#SUMMARY "MEF 6: Ingress Red Frames 24 hour Threshold Crossed." --#SEVERITY WARNING --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adGenMEFEvents 12 } adGenMEFSetPolicer24HrCongDiscardsIngressGreenFrames NOTIFICATION-TYPE OBJECTS { sysName, adGenMEFProfileAlias, adGenMEFProfileIndex } STATUS current DESCRIPTION "This trap indicates that the specified policer has crossed the 24 hour Congestion Discards Ingress Green Frames Threshold" --#TYPE "Status - Alarm" --#SUMMARY "MEF 6: Congestion Discards Ingress Green Frames 24 hour Threshold Crossed." --#SEVERITY WARNING --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adGenMEFEvents 13 } adGenMEFSetPolicer24HrCongDiscardsIngressYellowFrames NOTIFICATION-TYPE OBJECTS { sysName, adGenMEFProfileAlias, adGenMEFProfileIndex } STATUS current DESCRIPTION "This trap indicates that the specified policer has crossed the 24 hour Congestion Discards Ingress Yellow Frames Threshold" --#TYPE "Status - Alarm" --#SUMMARY "MEF 6: Congestion Discards Ingress Yellow Frames 24 hour Threshold Crossed." --#SEVERITY WARNING --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adGenMEFEvents 14 } --================================================================================================================== -- ****************************************************************************************** -- MIB Groups -- ****************************************************************************************** adGenMEFProvScalarGroup OBJECT-GROUP OBJECTS { adGenMEFDeleteAll, adGenMEFEVCIndexNext, adGenMEFMapIndexNext, adGenMEFProfileIndexNext, adGenMEFEVCEthertype } STATUS current DESCRIPTION "These objects provide support for the provisioning scalars." ::= { adGenMEFMibGroups 1 } adGenMEFProvEVCGroup OBJECT-GROUP OBJECTS { adGenMEFEVCIndex, adGenMEFEVCRowStatus, adGenMEFEVCAlias, adGenMEFEVCStatus, adGenMEFEVCPort, adGenMEFEVCCEVLANIDPreservation, adGenMEFEVCVLANID, adGenMEFEVCMapsByIndex, adGenMEFEVCNumMaps } STATUS current DESCRIPTION "These objects provide support for the EVC provisioning." ::= { adGenMEFMibGroups 2 } adGenMEFProvMapGroup OBJECT-GROUP OBJECTS { adGenMEFMapIndex, adGenMEFMapRowStatus, adGenMEFMapAlias, adGenMEFMapStatus, adGenMEFMapAssociatedEVCAlias, adGenMEFMapAssociatedEVCIndex, adGenMEFMapUNIPort, adGenMEFMapCEVLANID, adGenMEFMapCEVLANPRI, adGenMEFMapUntagged, adGenMEFMapCoS, adGenMEFMapAttachedProfileAlias, adGenMEFMapAttachedProfileIndex, adGenMEFMapBroadcast, adGenMEFMapMulticast, adGenMEFMapUnicast, adGenMEFMapL2CP, adGenMEFMapMenCTag, adGenMEFMapMenCTagPri, adGenMEFMapDSCPRange, adGenMEFMapIpHost } STATUS current DESCRIPTION "These objects provide support for the map provisioning." ::= { adGenMEFMibGroups 3 } adGenMEFProvProfileGroup OBJECT-GROUP OBJECTS { adGenMEFProfileIndex, adGenMEFProfileRowStatus, adGenMEFProfileAlias, adGenMEFProfileStatus, adGenMEFProfileApp, adGenMEFProfileUNIPort, adGenMEFProfileEVC, adGenMEFProfileCoSValue, adGenMEFProfileRateCoupling, adGenMEFProfileCBS, adGenMEFProfileEBS, adGenMEFProfileAddMap, adGenMEFProfileRemoveMap, adGenMEFProfileMapsByAlias, adGenMEFProfileMapsByIndex, adGenMEFProfileDroppedPackets, adGenMEFProfileCommittedInformationRate, adGenMEFProfileExcessInformationRate } STATUS current DESCRIPTION "These objects provide support for the profile provisioning." ::= { adGenMEFMibGroups 4 } adGenMEFProv10100EthQueueGroup OBJECT-GROUP OBJECTS { adGenMEFQueueWREDTimeConstant, adGenMEF10100EthCoSIndex, adGenMEF10100EthQueueMaxDepth, adGenMEF10100EthQueueWREDState, adGenMEF10100EthQueueWREDGreenMaxThresh, adGenMEF10100EthQueueWREDGreenMinThresh, adGenMEF10100EthQueueWREDGreenDropProb, adGenMEF10100EthQueueWREDYellowMaxThresh, adGenMEF10100EthQueueWREDYellowMinThresh, adGenMEF10100EthQueueWREDYellowDropProb } STATUS current DESCRIPTION "These objects provide support for the 10/100 Ethernet queue provisioning." ::= { adGenMEFMibGroups 5 } adGenMEFProvGigEthQueueGroup OBJECT-GROUP OBJECTS { adGenMEFQueueWREDTimeConstant, adGenMEFGigEthCoSIndex, adGenMEFGigEthQueueMaxDepth, adGenMEFGigEthQueueWREDState, adGenMEFGigEthQueueWREDGreenMaxThresh, adGenMEFGigEthQueueWREDGreenMinThresh, adGenMEFGigEthQueueWREDGreenDropProb, adGenMEFGigEthQueueWREDYellowMaxThresh, adGenMEFGigEthQueueWREDYellowMinThresh, adGenMEFGigEthQueueWREDYellowDropProb } STATUS current DESCRIPTION "These objects provide support for the Gigabit Ethernet queue provisioning." ::= { adGenMEFMibGroups 6 } adGenMEFProvBondGrpQueueGroup OBJECT-GROUP OBJECTS { adGenMEFQueueWREDTimeConstant, adGenMEFBondGrpCoSIndex, adGenMEFBondGrpQueueMaxDepth, adGenMEFBondGrpQueueWREDState, adGenMEFBondGrpQueueWREDGreenMaxThresh, adGenMEFBondGrpQueueWREDGreenMinThresh, adGenMEFBondGrpQueueWREDGreenDropProb, adGenMEFBondGrpQueueWREDYellowMaxThresh, adGenMEFBondGrpQueueWREDYellowMinThresh, adGenMEFBondGrpQueueWREDYellowDropProb } STATUS current DESCRIPTION "These objects provide support for the bonding group queue provisioning." ::= { adGenMEFMibGroups 7 } adGenMEFProvUNIGroup OBJECT-GROUP OBJECTS { adGenMEFUNIMapsByAlias, adGenMEFUNIMapsByIndex } STATUS current DESCRIPTION "These objects provide support for the UNI provisioning." ::= { adGenMEFMibGroups 8 } adGenMEFProvMENGroup OBJECT-GROUP OBJECTS { adGenMEFMENVLANIDPool } STATUS current DESCRIPTION "These objects provide support for the MEN provisioning." ::= { adGenMEFMibGroups 9 } adGenMEFProvQueueCoSMapGroup OBJECT-GROUP OBJECTS { adGenMEFQueueCoSMapForPri0, adGenMEFQueueCoSMapForPri1, adGenMEFQueueCoSMapForPri2, adGenMEFQueueCoSMapForPri3, adGenMEFQueueCoSMapForPri4, adGenMEFQueueCoSMapForPri5, adGenMEFQueueCoSMapForPri6, adGenMEFQueueCoSMapForPri7 } STATUS current DESCRIPTION "These objects provide support for the CoS mapping." ::= { adGenMEFMibGroups 10 } adGenMEFPolicerRstPerfGroup OBJECT-GROUP OBJECTS { adGenMEFPolicerRstCurrentIntervals, adGenMEFPolicerRstAll, adGenMEFPolicerPerfReset } STATUS current DESCRIPTION "These objects provide support for the Policer performance statistics resets." ::= { adGenMEFMibGroups 11 } adGenMEFPolicerPerfGroup OBJECT-GROUP OBJECTS { adGenMEFPolicer15MinCurrentIngressGreenFrames, adGenMEFPolicer15MinCurrentIngressYellowFrames, adGenMEFPolicer15MinCurrentIngressRedFrames, adGenMEFPolicer15MinCurrentIngressGreenOctets, adGenMEFPolicer15MinCurrentIngressYellowOctets, adGenMEFPolicer15MinCurrentIngressRedOctets, adGenMEFPolicer15MinCurrentCongDiscardsIngressGreenFrames, adGenMEFPolicer15MinCurrentCongDiscardsIngressGreenOctets, adGenMEFPolicer15MinCurrentCongDiscardsIngressYellowFrames, adGenMEFPolicer15MinCurrentCongDiscardsIngressYellowOctets, adGenMEFPolicer15MinCurrentHCIngressGreenFrames, adGenMEFPolicer15MinCurrentHCIngressYellowFrames, adGenMEFPolicer15MinCurrentHCIngressRedFrames, adGenMEFPolicer15MinCurrentHCIngressGreenOctets, adGenMEFPolicer15MinCurrentHCIngressYellowOctets, adGenMEFPolicer15MinCurrentHCIngressRedOctets, adGenMEFPolicer15MinCurrentHCCongDiscardsIngressGreenFrames, adGenMEFPolicer15MinCurrentHCCongDiscardsIngressGreenOctets, adGenMEFPolicer15MinCurrentHCCongDiscardsIngressYellowFrames, adGenMEFPolicer15MinCurrentHCCongDiscardsIngressYellowOctets, adGenMEFPolicer15MinIntervalNumber, adGenMEFPolicer15MinIntervalIngressGreenFrames, adGenMEFPolicer15MinIntervalIngressYellowFrames, adGenMEFPolicer15MinIntervalIngressRedFrames, adGenMEFPolicer15MinIntervalIngressGreenOctets, adGenMEFPolicer15MinIntervalIngressYellowOctets, adGenMEFPolicer15MinIntervalIngressRedOctets, adGenMEFPolicer15MinIntervalCongDiscardsIngressGreenFrames, adGenMEFPolicer15MinIntervalCongDiscardsIngressGreenOctets, adGenMEFPolicer15MinIntervalCongDiscardsIngressYellowFrames, adGenMEFPolicer15MinIntervalCongDiscardsIngressYellowOctets, adGenMEFPolicer15MinIntervalHCIngressGreenFrames, adGenMEFPolicer15MinIntervalHCIngressYellowFrames, adGenMEFPolicer15MinIntervalHCIngressRedFrames, adGenMEFPolicer15MinIntervalHCIngressGreenOctets, adGenMEFPolicer15MinIntervalHCIngressYellowOctets, adGenMEFPolicer15MinIntervalHCIngressRedOctets, adGenMEFPolicer15MinIntervalHCCongDiscardsIngressGreenFrames, adGenMEFPolicer15MinIntervalHCCongDiscardsIngressGreenOctets, adGenMEFPolicer15MinIntervalHCCongDiscardsIngressYellowFrames, adGenMEFPolicer15MinIntervalHCCongDiscardsIngressYellowOctets, adGenMEFPolicer24HrCurrentIngressGreenFrames, adGenMEFPolicer24HrCurrentIngressYellowFrames, adGenMEFPolicer24HrCurrentIngressRedFrames, adGenMEFPolicer24HrCurrentIngressGreenOctets, adGenMEFPolicer24HrCurrentIngressYellowOctets, adGenMEFPolicer24HrCurrentIngressRedOctets, adGenMEFPolicer24HrCurrentCongDiscardsIngressGreenFrames, adGenMEFPolicer24HrCurrentCongDiscardsIngressGreenOctets, adGenMEFPolicer24HrCurrentCongDiscardsIngressYellowFrames, adGenMEFPolicer24HrCurrentCongDiscardsIngressYellowOctets, adGenMEFPolicer24HrCurrentHCIngressGreenFrames, adGenMEFPolicer24HrCurrentHCIngressYellowFrames, adGenMEFPolicer24HrCurrentHCIngressRedFrames, adGenMEFPolicer24HrCurrentHCIngressGreenOctets, adGenMEFPolicer24HrCurrentHCIngressYellowOctets, adGenMEFPolicer24HrCurrentHCIngressRedOctets, adGenMEFPolicer24HrCurrentHCCongDiscardsIngressGreenFrames, adGenMEFPolicer24HrCurrentHCCongDiscardsIngressGreenOctets, adGenMEFPolicer24HrCurrentHCCongDiscardsIngressYellowFrames, adGenMEFPolicer24HrCurrentHCCongDiscardsIngressYellowOctets, adGenMEFPolicer24HrIntervalNumber, adGenMEFPolicer24HrIntervalIngressGreenFrames, adGenMEFPolicer24HrIntervalIngressYellowFrames, adGenMEFPolicer24HrIntervalIngressRedFrames, adGenMEFPolicer24HrIntervalIngressGreenOctets, adGenMEFPolicer24HrIntervalIngressYellowOctets, adGenMEFPolicer24HrIntervalIngressRedOctets, adGenMEFPolicer24HrIntervalCongDiscardsIngressGreenFrames, adGenMEFPolicer24HrIntervalCongDiscardsIngressGreenOctets, adGenMEFPolicer24HrIntervalCongDiscardsIngressYellowFrames, adGenMEFPolicer24HrIntervalCongDiscardsIngressYellowOctets, adGenMEFPolicer24HrIntervalHCIngressGreenFrames, adGenMEFPolicer24HrIntervalHCIngressYellowFrames, adGenMEFPolicer24HrIntervalHCIngressRedFrames, adGenMEFPolicer24HrIntervalHCIngressGreenOctets, adGenMEFPolicer24HrIntervalHCIngressYellowOctets, adGenMEFPolicer24HrIntervalHCIngressRedOctets, adGenMEFPolicer24HrIntervalHCCongDiscardsIngressGreenFrames, adGenMEFPolicer24HrIntervalHCCongDiscardsIngressGreenOctets, adGenMEFPolicer24HrIntervalHCCongDiscardsIngressYellowFrames, adGenMEFPolicer24HrIntervalHCCongDiscardsIngressYellowOctets } STATUS current DESCRIPTION "These objects provide support for the Policer performance statistics." ::= { adGenMEFMibGroups 12 } adGenMEFEthPerfGroup OBJECT-GROUP OBJECTS { adGenMEF10100EthAnomalies15MinCurrentFramesWithInvalidCEVLANID, adGenMEF10100EthAnomalies15MinIntervalNumber, adGenMEF10100EthAnomalies15MinIntervalFramesWithInvalidCEVLANID, adGenMEF10100EthAnomalies24HrCurrentFramesWithInvalidCEVLANID, adGenMEF10100EthAnomalies24HrIntervalNumber, adGenMEF10100EthAnomalies24HrIntervalFramesWithInvalidCEVLANID } STATUS current DESCRIPTION "These objects provide support for additional Ethernet performance statistics." ::= { adGenMEFMibGroups 13 } adGenMEFGigEthPerfGroup OBJECT-GROUP OBJECTS { adGenMEFGigEthAnomalies15MinCurrentFramesWithInvalidCEVLANID, adGenMEFGigEthAnomalies15MinIntervalNumber, adGenMEFGigEthAnomalies15MinIntervalFramesWithInvalidCEVLANID, adGenMEFGigEthAnomalies24HrCurrentFramesWithInvalidCEVLANID, adGenMEFGigEthAnomalies24HrIntervalNumber, adGenMEFGigEthAnomalies24HrIntervalFramesWithInvalidCEVLANID } STATUS current DESCRIPTION "These objects provide support for additional Gigabit Ethernet performance statistics." ::= { adGenMEFMibGroups 14 } adGenMEFEthThreshGroup OBJECT-GROUP OBJECTS { adGenMEF10100EthAnomalies15MinThreshFramesWithInvalidCEVLANID, adGenMEF10100EthAnomalies24HrThreshFramesWithInvalidCEVLANID } STATUS current DESCRIPTION "These objects provide support for additional Ethernet thresholds." ::= { adGenMEFMibGroups 15 } adGenMEFGigEthThreshGroup OBJECT-GROUP OBJECTS { adGenMEFGigEthAnomalies15MinThreshFramesWithInvalidCEVLANID, adGenMEFGigEthAnomalies24HrThreshFramesWithInvalidCEVLANID } STATUS current DESCRIPTION "These objects provide support for additional Gigabit Ethernet thresholds." ::= { adGenMEFMibGroups 16 } adGenMEFPolicerThreshGroup OBJECT-GROUP OBJECTS { adGenMEFPolicer15MinThresholdIngressGreenFrames, adGenMEFPolicer15MinThresholdIngressYellowFrames, adGenMEFPolicer15MinThresholdIngressRedFrames, adGenMEFPolicer15MinThresholdCongDiscardsIngressGreenFrames, adGenMEFPolicer15MinThresholdCongDiscardsIngressYellowFrames, adGenMEFPolicer15MinThresholdHCIngressGreenFrames, adGenMEFPolicer15MinThresholdHCIngressYellowFrames, adGenMEFPolicer15MinThresholdHCIngressRedFrames, adGenMEFPolicer15MinThresholdHCCongDiscardsIngressGreenFrames, adGenMEFPolicer15MinThresholdHCCongDiscardsIngressYellowFrames, adGenMEFPolicer24HrThresholdIngressGreenFrames, adGenMEFPolicer24HrThresholdIngressYellowFrames, adGenMEFPolicer24HrThresholdIngressRedFrames, adGenMEFPolicer24HrThresholdCongDiscardsIngressGreenFrames, adGenMEFPolicer24HrThresholdCongDiscardsIngressYellowFrames, adGenMEFPolicer24HrThresholdHCIngressGreenFrames, adGenMEFPolicer24HrThresholdHCIngressYellowFrames, adGenMEFPolicer24HrThresholdHCIngressRedFrames, adGenMEFPolicer24HrThresholdHCCongDiscardsIngressGreenFrames, adGenMEFPolicer24HrThresholdHCCongDiscardsIngressYellowFrames } STATUS current DESCRIPTION "These objects provide support for the Policer thresholds." ::= { adGenMEFMibGroups 17 } adGenMEFEventGroup NOTIFICATION-GROUP NOTIFICATIONS { adGenMEFSet10100EthAnomalies15MinFramesWithInvalidCEVLANID, adGenMEFSet10100EthAnomalies24HrFramesWithInvalidCEVLANID, adGenMEFSetGigEthAnomalies15MinFramesWithInvalidCEVLANID, adGenMEFSetGigEthAnomalies24HrFramesWithInvalidCEVLANID, adGenMEFSetPolicer15MinIngressGreenFrames, adGenMEFSetPolicer15MinIngressYellowFrames, adGenMEFSetPolicer15MinIngressRedFrames, adGenMEFSetPolicer15MinCongDiscardsIngressGreenFrames, adGenMEFSetPolicer15MinCongDiscardsIngressYellowFrames, adGenMEFSetPolicer24HrIngressGreenFrames, adGenMEFSetPolicer24HrIngressYellowFrames, adGenMEFSetPolicer24HrIngressRedFrames, adGenMEFSetPolicer24HrCongDiscardsIngressGreenFrames, adGenMEFSetPolicer24HrCongDiscardsIngressYellowFrames } STATUS current DESCRIPTION "These objects provide support for events." ::= { adGenMEFMibGroups 18 } adGenMEFDeprecatedGroup OBJECT-GROUP OBJECTS { adGenMEFProfileCIR, adGenMEFProfileEIR, adGenMEFMapDSCP } STATUS deprecated DESCRIPTION "These objects have been deprecated." ::= { adGenMEFMibGroups 19 } adGenMEFObsoletedGroup OBJECT-GROUP OBJECTS { adGenMEFEVCMapsByAlias } STATUS obsolete DESCRIPTION "These objects have been obsoleted." ::= { adGenMEFMibGroups 20 } END