ADTRAN-5KSCM-MIB DEFINITIONS ::= BEGIN -- TITLE: 5kSCM MIB Definitions -- FILENAME: ADTA5KSCM.MIB -- AUTHOR: Arthur Poleon -- DATE: 2003/04/04 -- -- ========================================================================== -- History -- ========================================================================== -- 01/29/04 AP For SCA OID, DB0(data bit zeo) corresponds to the Accessory Slot. -- 02/03/06 KMM Additional changes made while adding support for packed -- sstate msgs. Added: -- *) service state set single fail -- *) service state get single fail -- *) service state set all fail -- *) service state get all fail -- 04/03/06 KMM Removed alarms added on 02/03/06. These are auto-clearing alarms, therefore -- do not have alarm status. -- 04/17/06 JMC Added Power Bus B Alarm active and clear. -- 05/03/06 JMC Fixed up some outdated descriptions. -- 05/04/06 JMC Fixed up some outdated descriptions, again. -- 05/09/06 JMC Added power shedding bit definitions to commments. -- 05/17/06 JMC Fixed alarm status bit for power shedding. -- 05/26/06 JMC Addition of Power Shedding alarms, cleanup. -- 06/01/06 JMC Lots of cleanup to bit definitions and commenting. -- Fixup to adta5kSCMShelfRelatedAlarmStatus. -- 06/05/06 JMC Fixed adGenSlotAlarmStatus Bits 40-54. -- 06/06/06 JMC Removed some adGenSlotAlarmStatus bits - shouldn't have been there. -- 06/09/06 JMC Removed Card Removed and Fuse Blown status in adGenSlotAlarmStatus OID. -- 10/19/06 AP Remove adta5kSCMAlarmIndex index range. -- 06/28/06 AP Increase adta5kSCMAIDIndex value range from 40 to 128. -- 03/27/08 WFE Added adTASCM5kChassisRemoved, adTASCM5kChassisLinkStatusDown, and -- adTASCM5kChassisLinkStatusUp traps. -- Updated adGenSlotAlarmStatus bits. -- 09/26/13 RJF "DO NOT MAKE HISTORY COMMENTS HERE!!!! Revision history now in REVISION/DESCRIPTION clauses below" -- -- ========================================================================== -- ========================================================================== -- This MIB defines the enterprise specific MIB for the TA5000 SCM. -- ========================================================================== -- ADTRAN standard (ADTRAN) -- ADTRAN textual conventions (adtrantc) -- ADTRAN generic chassis (genchass) -- ADTRAN generic slot (genslot) -- -- -- ========================================================================== -- adGenSlotFaceplate -- ========================================================================== -- The various values for each LED are: -- 00 Off -- 01 Green -- 10 Red -- 11 Yellow -- There the 9 faceplate LEDs. Each LED is represented by two bits. -- The first byte indicates the number of LEDs; the remaining -- bytes encode the status of the LEDs in order from top to bottom. -- The mapping of the 3 bytes is illustrated below: -- 1,2 3,4 5,6 7,8 9,10 11,12 13,14 15,16 17,18 -- LAN HOST ACO CRI MAJ MIN TEST ALM PWR -- 1188010G2 -- 1,2 3,4 5,6 7,8 9,10 11,12 13,14 15,16 -- HOST ACO CRI MAJ MIN TEST ALM PWR -- 1188011G1 -- Same as 1188010G2 Plus -- 17,18 19,20 21,22 23,24 -- ETH2 ETH-ACT ETH ETH-ACT -- -- 1187011G1 TA5k System Controller w/ Bridging (Domestic) -- 1,2 3,4 5,6 7,8 9,10 11,12 13,14 15,16 17,18 19,20 21,22 -- LAN HOST ACO CRI MAJ MIN TEST ALM PWR ETH2 ETH2-ACT -- -- ========================================================================== -- adGenSlotAlarmStatus -- ========================================================================== -- ========================================================================= -- Bits Details for 1-16 SCM alarm/status -- ========================================================================= -- Bit 1 Indicates that a alarm is present on the SCM. -- ========================================================================= -- Bit 2 Alarm cut-off is on -- Bit 3 Alarm cut-off input is active -- ========================================================================= -- Bit 4 N/A -- Bit 5 N/A -- Bit 6 N/A -- ========================================================================= -- Bit 7 adTAeSCUCtrpBusApowerAlm (-48V Power Supply A alarm is active) -- Bit 8 adTAeSCUCtrpBusBpowerAlm (-48V Power Supply B alarm is active) -- Bit 9 Device comm failure - this is not a SNMP alarm -- Bit 10 One or more card fuses on this chassis is open -- Bit 11 adTAeSCUCraftLoginNotfication -- ========================================================================= -- Bit 12 N/A -- Bit 13 N/A -- Bit 14 N/A -- Bit 15 N/A -- Bit 16 N/A -- Bit 17 N/A -- Bit 18 N/A -- Bit 19 N/A -- Bit 20 N/A -- ========================================================================= -- Bit 21 adTAPowerSheddingInputAsserted -- Bit 22 adTAPowerSheddingActivated -- ========================================================================= -- Bit 23 N/A -- ========================================================================= -- Bit 24 adSCM5kExternalAlm Input 1 -- Bit 25 adSCM5kExternalAlm Input 2 -- Bit 26 adSCM5kExternalAlm Input 3 -- Bit 27 adSCM5kExternalAlm Input 4 -- Bit 28 adSCM5kExternalAlm Input 5 -- Bit 29 adSCM5kExternalAlm Input 6 -- Bit 30 adSCM5kExternalAlm Input 7 -- Bit 31 adSCM5kExternalAlm Input 8 -- Bit 32 adSCM5kExternalAlm Input 9 -- Bit 33 adSCM5kExternalAlm Input 10 -- Bit 34 adSCM5kExternalAlm Input 11 -- Bit 35 adSCM5kExternalAlm Input 12 -- Bit 36 adSCM5kExternalAlm Input 13 -- Bit 37 adSCM5kExternalAlm Input 14 -- Bit 38 adSCM5kExternalAlm Input 15 -- Bit 39 adSCM5kExternalAlm Input 16 -- ========================================================================= -- Bit 40 adTACriticalAudibleRelayActive -- Bit 41 adTACriticalVisualRelayActive -- Bit 42 adTAMajAudibleRelayActive -- Bit 43 adTAMajVisualRelayActive -- Bit 44 adTAMinorAudibleRelayActive -- Bit 45 adTAMinorVisualRelayActive -- Bit 46 adTAAUSoftwareVerErrorActive -- Bit 47 adTASCM5kChassisLinkStatusDown Shelf 2 -- Bit 48 adTASCM5kChassisLinkStatusDown Shelf 3 -- Bit 49 adTASCM5kChassisLinkStatusDown Shelf 4 -- Bit 50 Reserved (Deprecated) -- Bit 51 Reserved (Deprecated) -- Bit 52 Reserved -- Bit 53 Reserved -- Bit 54 AutoUpgrade End Of Software Support Warning (adTaSysCtrlAutoUpgradeEOSSWarning) -- Bit 55 AutoUpgrade End Of Software Support Denied (adTaSysCtrlAutoUpgradeEOSSDenied) -- ========================================================================== IMPORTS NOTIFICATION-TYPE, OBJECT-TYPE, Integer32, MODULE-IDENTITY, OBJECT-IDENTITY, TimeTicks FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC sysName FROM SNMPv2-MIB AdPresence FROM ADTRAN-TC adProducts, adMgmt FROM ADTRAN-MIB adGenSlotInfoIndex FROM ADTRAN-GENSLOT-MIB adTrapInformSeqNum FROM ADTRAN-GENTRAPINFORM-MIB adTAeSCUTrapAlarmLevel FROM ADTRAN-TAeSCUEXT1-MIB; adTA5kSCMmg MODULE-IDENTITY LAST-UPDATED "201309130752Z" ORGANIZATION "Adtran, Inc." CONTACT-INFO "CND Tech Support Postal: ADTRAN, Inc. 901 Explorer Blvd. Huntsville, AL 35806 Tel: +1 800 726-8663 Fax: +1 256 963 6217 E-mail: support@adtran.com" DESCRIPTION "This MIB defines the objects for the adta5KSCM MIB." REVISION "201309130752Z" DESCRIPTION "Added adGenSlotAlarmStatus comments for new EOSS alarms." REVISION "201104251300Z" DESCRIPTION "Add comment for SCM LED format." REVISION "201002241300Z" DESCRIPTION "Converted from SNMPv1 adta5kSCM.mib file." ::= { adMgmt 749 } -- OBJECT IDENTIFIERS adTA5kSCM OBJECT IDENTIFIER ::= { adProducts 749 } -- adTA5kSCMmg OBJECT IDENTIFIER ::= { adMgmt 749 } adta5kSCMMgmt OBJECT IDENTIFIER ::= { adTA5kSCMmg 1 } -- -- 5kSCM and MUXA and MUXB is in first shelf. -- To determine a line card shelf number you must -- ((adGenSlotInfoIndex - 1) / ad5kSCMNumSlotPerShelf + 1) for line cards, -- and the shelf slot number is ((adGenSlotInfoIndex - 1) modulus ad5kSCMNumSlotPerShelf + 1). -- However, I thought that the original idea was to make this look like a system and that cards would be addressed by their slot number across the entire . When do you expect this table to be used. -- A type to define 5kSCM shelf numbers -- Number of shelves possible in this DSLAM (HDX). Default is 1. Adta5kSCMShelfNumber ::= Integer32 ( 1..255) -- Count of shelves provisioned to be installed, starting at 1. adta5kSCMNumberOfShelves OBJECT-TYPE SYNTAX Adta5kSCMShelfNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Defines the number of shelves presently provisioned in the system. Provisioning is done in the PSM provisioning menu." ::= { adta5kSCMMgmt 10 } adta5kSCMLastChanged OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The sysUpTime When adta5kSCMNumberOfShelves changed, or any adta5kSCMShelfInfoState changed. Zero if unchanged since powerup" ::= { adta5kSCMMgmt 2 } -- -- -- adta5kSCMShelfStatusMgmt OBJECT IDENTIFIER ::= { adta5kSCMMgmt 12 } adta5kSCMShelfStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Adta5kSCMShelfStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Comparable to the GENCHASSIS MIB, but applicable for all shelves in a subtended system like the HDX." ::= { adta5kSCMShelfStatusMgmt 1 } adta5kSCMShelfStatusEntry OBJECT-TYPE SYNTAX Adta5kSCMShelfStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { adta5kSCMShelfNumber } ::= { adta5kSCMShelfStatusTable 1 } Adta5kSCMShelfStatusEntry ::= SEQUENCE { adta5kSCMShelfNumber Adta5kSCMShelfNumber, adta5kSCMShelfInfoState AdPresence, adta5kSCMShelfAlarmStatus OCTET STRING, adta5kSCMShelfProvVersion Integer32, adta5kSCMShelfViewAll OCTET STRING, adta5kSCMShelfRelatedAlarmStatus OCTET STRING } adta5kSCMShelfNumber OBJECT-TYPE SYNTAX Adta5kSCMShelfNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Index for each row in this table." ::= { adta5kSCMShelfStatusEntry 1 } adta5kSCMShelfInfoState OBJECT-TYPE SYNTAX AdPresence MAX-ACCESS read-only STATUS current DESCRIPTION "Return the shelf status: empty(1): Not provisioned to be present, virtual(2): Provisioned but not operational (link status down), occupied(3): Provisioned and operational." ::= { adta5kSCMShelfStatusEntry 2 } adta5kSCMShelfAlarmStatus OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "A bit encoded string representing a summary of the alarm state of the chassis" ::= { adta5kSCMShelfStatusEntry 3 } adta5kSCMShelfProvVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The sum of all the card Provisioning Counters in the generic slot MIB for this shelf that can be used by an EMS to detect local changes to card provisioning that need to be investigated for synchronization." ::= { adta5kSCMShelfStatusEntry 4 } adta5kSCMShelfViewAll OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "A bit encoded string representing the status of faceplate indicators, LEDs, & switches for GUI visualization. Each product defines this as a bitmap of booleans, or a byte for each indicator if not binary. The strings from all the slots are concatenated into this one object, after prefixing each card indicator string with two bytes. The first byte contains the slot number as an integer, and the second byte contains the remaining string length for that slot. This object provides highest speed access for chassis views to overcome multiple varbind SNMP inefficiency." ::= { adta5kSCMShelfStatusEntry 5 } adta5kSCMShelfRelatedAlarmStatus OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "A bit encoded string representing the alarm status of the environmental alarms for each shelf. The bits are defined in network order, that is, most significant bit first. 0 = NOT-ALARMED, 1 = ALARMED The bit positions are: 1 - PWR A 2 - PWR B 3 - N/A 4 - N/A 5 - N/A 6 - N/A 7 - N/A" ::= { adta5kSCMShelfStatusEntry 6 } -- -- -- Mapping table to translate from system slot number to shelf and local slot number adta5kSCMShelfXlateFromSlotTable OBJECT-TYPE SYNTAX SEQUENCE OF Adta5kSCMShelfXlateFromSlotEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of slots available for boards." ::= { adta5kSCMShelfStatusMgmt 2 } adta5kSCMShelfXlateFromSlotEntry OBJECT-TYPE SYNTAX Adta5kSCMShelfXlateFromSlotEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { adGenSlotInfoIndex} ::= { adta5kSCMShelfXlateFromSlotTable 1 } Adta5kSCMShelfXlateFromSlotEntry ::= SEQUENCE { adta5kSCMShelfOrdinal Adta5kSCMShelfNumber, adta5kSCMShelfSlotAddress Integer32 } adta5kSCMShelfOrdinal OBJECT-TYPE SYNTAX Adta5kSCMShelfNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Return the chassis number that corresponds to the adGenSlotInfoIndex." ::= { adta5kSCMShelfXlateFromSlotEntry 1 } adta5kSCMShelfSlotAddress OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the chassis relative slot number that corresponds to the adGenSlotInfoIndex." ::= { adta5kSCMShelfXlateFromSlotEntry 2 } --- --- --- Mapping table to translate from shelf and slot number to system slot number adta5kSCMShelfXlateToSlotTable OBJECT-TYPE SYNTAX SEQUENCE OF Adta5kSCMShelfXlateToSlotEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of slots available for boards." ::= { adta5kSCMShelfStatusMgmt 3 } adta5kSCMShelfXlateToSlotEntry OBJECT-TYPE SYNTAX Adta5kSCMShelfXlateToSlotEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { adGenSlotInfoIndex, adta5kSCMShelfNumberAddress} ::= { adta5kSCMShelfXlateToSlotTable 1 } Adta5kSCMShelfXlateToSlotEntry ::= SEQUENCE { adta5kSCMSystemSlotAddress Integer32, adta5kSCMShelfNumberAddress Integer32 } adta5kSCMSystemSlotAddress OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The global DSLAM slot corresponding to this shelf relative slot." ::= { adta5kSCMShelfXlateToSlotEntry 1 } adta5kSCMShelfNumberAddress OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The Shelf Address/Number." ::= { adta5kSCMShelfXlateToSlotEntry 2 } --- --- --- Extension of genslot.mib for trap authentication status checking adta5kSCMShelfSlotAlarmStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Adta5kSCMShelfSlotAlarmStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of slot alarms for states the cards themselves cannot report for various reasons." ::= { adta5kSCMShelfStatusMgmt 4 } adta5kSCMShelfSlotAlarmStatusEntry OBJECT-TYPE SYNTAX Adta5kSCMShelfSlotAlarmStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { adGenSlotInfoIndex } ::= { adta5kSCMShelfSlotAlarmStatusTable 1 } Adta5kSCMShelfSlotAlarmStatusEntry ::= SEQUENCE { adta5kSCMShelfSlotAlarmStatus OCTET STRING } adta5kSCMShelfSlotAlarmStatus OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "A bit encoded string representing the alarm status of the certain card/slot alarms for each HDX slot. The bits are defined in network order, that is, most significant bit first. 0 = NOT-ALARMED, 1 = ALARMED The bit positions are: 1 - Card Removed 2 - Fuse Blown" ::= { adta5kSCMShelfSlotAlarmStatusEntry 1 } --- --- --- Shelf specific provisionable environmental alarms adta5kSCMUserDefinableAlarm OBJECT IDENTIFIER ::= { adta5kSCMMgmt 15 } adta5kSCMEnvAlarmsTable OBJECT-TYPE SYNTAX SEQUENCE OF Adta5kSCMEnvAlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The 5kSCM Environmental alarm table with the following alarms: This table is a superset of the the adTAeSCUEnvAlarmsTable. It includes the environmental alarms of the subtended shelves." ::= { adta5kSCMUserDefinableAlarm 1 } adta5kSCMEnvAlarmsEntry OBJECT-TYPE SYNTAX Adta5kSCMEnvAlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Controller Unit Environmental alarm table." INDEX { adta5kSCMShelfNumber, adta5kSCMAlarmIndex} ::= { adta5kSCMEnvAlarmsTable 1 } Adta5kSCMEnvAlarmsEntry ::= SEQUENCE { adta5kSCMAlarmIndex Integer32, adta5kSCMEnvAlarmDefaultName DisplayString, adta5kSCMEnvAlarmUserName DisplayString, adta5kSCMEnvAlarmInputLevel INTEGER, adta5kSCMAIDIndex Integer32, adta5kSCMConditionCode DisplayString } adta5kSCMAlarmIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm Index for type of environmental alarm." ::= { adta5kSCMEnvAlarmsEntry 1 } adta5kSCMEnvAlarmDefaultName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Default ENV alarm name." ::= { adta5kSCMEnvAlarmsEntry 2 } adta5kSCMEnvAlarmUserName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "A user specified name. adta5kSCMEnvAlarmDefaultName or a user provided name. '-48V Bus A Input' is read-only. '-48V Bus B Input' is read-only." ::= { adta5kSCMEnvAlarmsEntry 3 } adta5kSCMEnvAlarmInputLevel OBJECT-TYPE SYNTAX INTEGER { info(2), alert(3), minor(4), major(5), critical(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Alarm level." ::= { adta5kSCMEnvAlarmsEntry 4 } adta5kSCMAIDIndex OBJECT-TYPE SYNTAX Integer32 (1..128) MAX-ACCESS read-write STATUS current DESCRIPTION "AID Index. -48V Bus A Input has a maximum range of 45 -48V Bus B Input has a maximum range of 45 All other alarms will have a max index range of 64." ::= { adta5kSCMEnvAlarmsEntry 5 } adta5kSCMConditionCode OBJECT-TYPE SYNTAX DisplayString (SIZE(0..11)) MAX-ACCESS read-write STATUS current DESCRIPTION "Condition code." ::= { adta5kSCMEnvAlarmsEntry 6 } -- -- 5kSCM SCA support for primary and secondary shelves -- adta5kSCMScaMgmt OBJECT IDENTIFIER ::= { adta5kSCMMgmt 16 } adta5kSCMScaTable OBJECT-TYPE SYNTAX SEQUENCE OF Adta5kSCMScaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Expansion OIDs for the HDX system." ::= { adta5kSCMScaMgmt 1 } adta5kSCMScaEntry OBJECT-TYPE SYNTAX Adta5kSCMScaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { adta5kSCMShelfNumber } ::= { adta5kSCMScaTable 1 } Adta5kSCMScaEntry ::= SEQUENCE { adTAe5kSCMSCAProvItemChanged Integer32, adTAe5kSCMSCAPresentCards Integer32, adTAe5kSCMSCASlotsWithProvData Integer32, adTAe5kSCMSCAoptRestoreCardBitmask Integer32 } adTAe5kSCMSCAProvItemChanged OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Bitmap of cards with changed provisions. This read-only OID will return a bitmap of slots whose provisions have changed since power-up or the last SCA save operation. DB1 corresponds to slot 1, DB31 corresponds to slot 31. DB0 corresponds to the Accessory Slot" ::= { adta5kSCMScaEntry 1 } adTAe5kSCMSCAPresentCards OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Bitmap of card 'present' in the shelf. This read-only OID will return a bitmap of slots with cards installed. DB1 corresponds to slot 1, DB31 corresponds to slot 31. DB0 corresponds to the Accessory Slot." ::= { adta5kSCMScaEntry 2 } adTAe5kSCMSCASlotsWithProvData OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Bitmap of slots with provision data. This read-only OID will return a bitmap of slots with provision information. DB1 corresponds to slot 1, DB31 corresponds to slot 31. DB0 corresponds to the Accessory Slot" ::= { adta5kSCMScaEntry 3 } adTAe5kSCMSCAoptRestoreCardBitmask OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SCA restore to linecard enable bitmask. This OID accesses a enable/disable bitmap indicating which slots should have their provision information restored during an SCA restore operation. Valid slots are 1..30 or 1..24, depending on shelf type. DB1 corresponds to slot 1, DB31 corresponds to slot 31." ::= { adta5kSCMScaEntry 4 } -- 5kSCM environmental alarms -- 5kSCM Chassis Traps adTA5kSCMNotificationEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The SCM controller events" ::= { adTA5kSCM 0 } adSCM5kExternalAlmClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adta5kSCMEnvAlarmUserName, adta5kSCMEnvAlarmInputLevel } STATUS current DESCRIPTION "External Alarm clear" --#TYPE "Warning - External Alarm Failure " --#SUMMARY "adTA5kSCM 74902: External Alarm;" --#SUMMARY "detected at shelf: %s" --#ARGUMENTS { 1 } --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTA5kSCMNotificationEvents 74902 } adSCM5kExternalAlm NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adta5kSCMEnvAlarmUserName, adta5kSCMEnvAlarmInputLevel } STATUS current DESCRIPTION "External Failure Alarm active" --#TYPE "Warning - External Failure Alarm active" --#SUMMARY "adTA5kSCM 74903: External Alarm active;" --#SUMMARY "detected at shelf: %s" --#ARGUMENTS { 1 } --#SEVERITY MINOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTA5kSCMNotificationEvents 74903 } adTASCM5kBusApwrAlmClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adta5kSCMShelfNumber, adta5kSCMEnvAlarmUserName, adta5kSCMEnvAlarmInputLevel } STATUS current DESCRIPTION "Bus A Power Failure Alarm clear" --#TYPE "Informational - Bus A Power Failure Alarm clear" --#SUMMARY "adTA5kSCM 74904: Bus A Power Failure Alarm cleared;" --#SUMMARY "detected at 5kSCM: %s Shelf %d, Alarm: %s" --#ARGUMENTS { 1 , 2, 3} --#SEVERITY INFORMATIONAL --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTA5kSCMNotificationEvents 74904 } adTASCM5kBusApowerAlm NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adta5kSCMShelfNumber, adta5kSCMEnvAlarmUserName, adta5kSCMEnvAlarmInputLevel } STATUS current DESCRIPTION "Bus A Power Failure Alarm active" --#TYPE "Major - Bus A Power Failure Alarm active" --#SUMMARY "adTA5kSCM 74905: Bus A Power Failure Alarm active;" --#SUMMARY "detected at 5kSCM: %s Shelf %d, Alarm: %s" --#ARGUMENTS { 1 , 2, 3} --#SEVERITY MAJOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTA5kSCMNotificationEvents 74905 } adTASCM5kBusBpwrAlmClear NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adta5kSCMShelfNumber, adta5kSCMEnvAlarmUserName, adta5kSCMEnvAlarmInputLevel } STATUS current DESCRIPTION "Bus B Power Failure Alarm clear" --#TYPE "Informational - Bus B Power Failure Alarm clear" --#SUMMARY "adTA5kSCM 74906: Bus B Power Failure Alarm cleared;" --#SUMMARY "detected at 5kSCM: %s Shelf %d, Alarm: %s" --#ARGUMENTS { 1 , 2, 3} --#SEVERITY INFORMATIONAL --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTA5kSCMNotificationEvents 74906 } adTASCM5kBusBpowerAlm NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adta5kSCMShelfNumber, adta5kSCMEnvAlarmUserName, adta5kSCMEnvAlarmInputLevel } STATUS current DESCRIPTION "Bus B Power Failure Alarm active" --#TYPE "Major - Bus B Power Failure Alarm active" --#SUMMARY "adTA5kSCM 74907: Bus B Power Failure Alarm active;" --#SUMMARY "detected at 5kSCM: %s Shelf %d, Alarm: %s" --#ARGUMENTS { 1 , 2, 3} --#SEVERITY MAJOR --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTA5kSCMNotificationEvents 74907 } adTASCM5kChassisLinkStatusUp NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adta5kSCMShelfNumber, adTAeSCUTrapAlarmLevel } STATUS current DESCRIPTION "SCM has detected a chassis link up." --#TYPE "Informational - Chassis link down clear" --#SUMMARY "adTA5kSCM 74908: Chassis link down clear;" --#SUMMARY "detected at HDX: %s Shelf %d" --#ARGUMENTS { 1 , 2} --#SEVERITY INFORMATIONAL --#GENERIC 6 --#CATEGORY "Configuration Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTA5kSCMNotificationEvents 74908 } adTASCM5kChassisLinkStatusDown NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adta5kSCMShelfNumber, adTAeSCUTrapAlarmLevel } STATUS current DESCRIPTION "SCM has detected a chassis link down." --#TYPE "Critical - Chassis link down active" --#SUMMARY "adTA5kSCM 74909: Chassis link down active;" --#SUMMARY "detected at HDX: %s Shelf %d" --#ARGUMENTS { 1 , 2} --#SEVERITY CRITICAL --#GENERIC 6 --#CATEGORY "Error Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTA5kSCMNotificationEvents 74909 } adTASCM5kChassisRemoved NOTIFICATION-TYPE OBJECTS { adTrapInformSeqNum, sysName, adta5kSCMShelfNumber, adTAeSCUTrapAlarmLevel } STATUS current DESCRIPTION "SCM has removed the last chassis because of a provisioning change. All modules in the chassis will be removed." --#TYPE "Informational - Chassis removed provisioned active" --#SUMMARY "adTA5kSCM 74911: Chassis removed provisioned;" --#SUMMARY "detected at HDX: %s Shelf %d" --#ARGUMENTS { 1 , 2} --#SEVERITY INFORMATIONAL --#GENERIC 6 --#CATEGORY "Configuration Events" --#SOURCE_ID "A" --#TIMEINDEX 0 ::= { adTA5kSCMNotificationEvents 74910 } END