-- ***************************************************************** -- QTECH-RSTP-MIB.mib: Qtech RSTP MIB file -- -- March 2002, Wuzg -- -- Copyright (c) 2002 by Qtech Networks Co.,Ltd. -- All rights reserved. -- -- ***************************************************************** -- QTECH-RSTP-MSTP-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, TimeTicks, Integer32, Counter32 FROM SNMPv2-SMI TruthValue, DisplayString FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF IfIndex, ConfigStatus FROM QTECH-TC BridgeId FROM BRIDGE-MIB EnabledStatus FROM P-BRIDGE-MIB qtechMgmt FROM QTECH-SMI; qtechStpMIB MODULE-IDENTITY LAST-UPDATED "200203200000Z" ORGANIZATION "Qtech Networks Co.,Ltd." CONTACT-INFO " Tel: 4008-111-000 E-mail: service@qtech.com.cn" DESCRIPTION "This module defines qtech stp mibs." REVISION "200203200000Z" DESCRIPTION "Initial version of this MIB module." ::= { qtechMgmt 16} qtechStpMIBObjects OBJECT IDENTIFIER ::= { qtechStpMIB 1 } qtechRstpMIBObjects OBJECT IDENTIFIER ::= { qtechStpMIB 2 } qtechMstpMIBObjects OBJECT IDENTIFIER ::= { qtechStpMIB 3 } -- ------------------------------------------------------------- -- extend of stp -- ------------------------------------------------------------- qtechSysStpStatus OBJECT-TYPE SYNTAX EnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "This object allow of enabling or disabling the Spanning Tree Protocol in the system, this will avoid the circle exist in the net environment, then avoid the broad cast storm. and when set its value to enable(1) will cause a short time that the station can not connect the agent, waitting for the topology become stable." DEFVAL { disabled } ::= { qtechStpMIBObjects 1 } qtechSysStpReset OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object allow of resetting all Spanning Tree Protocol parameter reset to default settings. set its value to any but 0, will cause agent reset the parameters, set it to 0 will cause no action. this operation may cause some interval the station can not connect the agent depending on the parameters previous set." ::= { qtechStpMIBObjects 2 } qtechStpExtPortTable OBJECT-TYPE SYNTAX SEQUENCE OF QtechStpExtPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains port-specific Spanning Tree extend information." ::= { qtechStpMIBObjects 3 } qtechStpExtPortEntry OBJECT-TYPE SYNTAX QtechStpExtPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Spanning Tree extend information maintained by each port." INDEX { qtechStpPortIfIndex } ::= { qtechStpExtPortTable 1 } QtechStpExtPortEntry ::= SEQUENCE { qtechStpPortIfIndex IfIndex, qtechStpPortAdminPathCost INTEGER, qtechStpPortOperPathCost INTEGER, qtechStpPortRole INTEGER -- qtechStpPortIfRunSTP -- TruthValue } qtechStpPortIfIndex OBJECT-TYPE SYNTAX IfIndex MAX-ACCESS read-only STATUS current DESCRIPTION "include only physical port and trunk port " ::= { qtechStpExtPortEntry 1 } qtechStpPortAdminPathCost OBJECT-TYPE SYNTAX INTEGER (0..200000000) MAX-ACCESS read-write STATUS current DESCRIPTION "The contribution of this port to the path cost of paths towards the spanning tree root which include this port. 802.1D-1990 recommends that the default value of this parameter be in inverse proportion to the speed of the attached LAN. Setting this value to 0 indicates that port's real path cost will be automaticly assigned by system according to duplex and speed of the port.Setting this value to other value and system will assigned this value to the port." DEFVAL{0} ::= { qtechStpExtPortEntry 2 } qtechStpPortOperPathCost OBJECT-TYPE SYNTAX INTEGER (1..200000000) MAX-ACCESS read-only STATUS current DESCRIPTION " Actual oper value of port cost." ::= { qtechStpExtPortEntry 3 } qtechStpPortRole OBJECT-TYPE SYNTAX INTEGER { disabledPort(1), alternatePort(2), backupPort(3), rootPort(4), designatedPort(5), masterPort(6) } MAX-ACCESS read-only STATUS current DESCRIPTION " Actual role of port in stp." ::= { qtechStpExtPortEntry 4 } --qtechStpPortIfRunSTP OBJECT-TYPE -- SYNTAX TruthValue -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "When the value is true the port will take part in the spanning tree algorithm, -- that is, if the topology of a port is changed will this be sensed by the algorithm -- or not." -- ::= { qtechStpExtPortEntry 5 } -- ------------------------------------------------------------- -- RSTP / CIST ieee 802.1s-d14-1 12.8.1 -- ------------------------------------------------------------- -- Addition to the dot1dStp group qtechStpVersion OBJECT-TYPE SYNTAX INTEGER { stpCompatible(0), rstp(2), mstp(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The version of Spanning Tree Protocol the bridge is currently running. The value 'stpCompatible(0)' indicates the Spanning Tree Protocol specified in IEEE 802.1D , 'rstp(2)' indicates the Rapid Spanning Tree Protocol specified in IEEE 802.1w mstp(3) indicates the Multiple spanning tree protocol specified in IEEE 802.1s. New value may be defined as future versions of the protocol become available." REFERENCE "IEEE 802.1w clause 14.8.1, 17.12, 17.16.1" DEFVAL { mstp } ::= { qtechRstpMIBObjects 1 } qtechStpTxHoldCount OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "The value used by the Port Transmit state machine to limit the maximum transmission rate." REFERENCE "IEEE 802.1w clause 17.16.6" DEFVAL { 3 } ::= { qtechRstpMIBObjects 2 } qtechStpPathCostDefault OBJECT-TYPE SYNTAX INTEGER { stp8021d1998(1), stp8021t2001(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The version of the Spanning Tree default Path Costs that are to be used by this Bridge. A value of 8021d1998(1) uses the 16-bit default Path Costs from IEEE Std. 802.1D-1998. A value of stp8021t2001(2) uses the 32-bit default Path Costs from IEEE Std. 802.1t." REFERENCE "IEEE 802.1D & 802.1t Table 8-5" ::= { qtechRstpMIBObjects 3 } qtechRstpExtPortTable OBJECT-TYPE SYNTAX SEQUENCE OF QtechRstpExtPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains port-specific Rapid Spanning Tree information." ::= { qtechRstpMIBObjects 4 } qtechRstpExtPortEntry OBJECT-TYPE SYNTAX QtechRstpExtPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Rapid Spanning Tree information maintained by each port." INDEX { qtechRstpExtPortIfIndex } ::= { qtechRstpExtPortTable 1 } QtechRstpExtPortEntry ::= SEQUENCE { qtechRstpExtPortIfIndex IfIndex, qtechStpPortProtocolMigration TruthValue, qtechStpPortAdminEdgePort TruthValue, qtechStpPortOperEdgePort TruthValue, qtechStpPortAdminPointToPoint INTEGER, qtechStpPortOperPointToPoint TruthValue, qtechStpPortBpduGuard EnabledStatus, qtechStpPortBpduFilter EnabledStatus } qtechRstpExtPortIfIndex OBJECT-TYPE SYNTAX IfIndex MAX-ACCESS read-only STATUS current DESCRIPTION "include only physical port and trunk port " ::= { qtechRstpExtPortEntry 1 } qtechStpPortProtocolMigration OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "When operating in RSTP (version 2) mode, writing TRUE(1) to this object forces this port to transmit RSTP BPDUs. Any other operation on this object has no effect and it always returns FALSE(2) when read." REFERENCE "IEEE 802.1w clause 14.8.2.4, 17.18.10, 17.26" ::= { qtechRstpExtPortEntry 2 } qtechStpPortAdminEdgePort OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "The administrative value of the Edge Port parameter. A value of TRUE(1) indicates that this port should be assumed as an edge-port and a value of FALSE(2) indicates that this port should be assumed as a non-edge-port." REFERENCE "IEEE 802.1t clause 14.8.2, 18.3.3" ::= { qtechRstpExtPortEntry 3 } qtechStpPortOperEdgePort OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The operational value of the Edge Port parameter. The object is initialized to the value of qtechStpPortAdminEdgePort and is set FALSE on reception of a BPDU." REFERENCE "IEEE 802.1t clause 14.8.2, 18.3.4" ::= { qtechRstpExtPortEntry 4 } qtechStpPortAdminPointToPoint OBJECT-TYPE SYNTAX INTEGER { forceTrue(0), forceFalse(1), auto(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The administrative point-to-point status of the LAN segment attached to this port. A value of forceTrue(0) indicates that this port should always be treated as if it is connected to a point-to-point link. A value of forceFalse(1) indicates that this port should be treated as having a shared media connection. A value of auto(2) indicates that this port is considered to have a point-to-point link if it is an Aggregator and all of its members are aggregatable, or if the MAC entity is configured for full duplex operation, either through auto-negotiation or by management means." REFERENCE "IEEE 802.1w clause 6.4.3, 6.5, 14.8.2" ::= { qtechRstpExtPortEntry 5 } qtechStpPortOperPointToPoint OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The operational point-to-point status of the LAN segment attached to this port. It indicates whether a port is considered to have a point-to-point connection or not. The value is determined by management or by auto-detection, as described in the qtechStpPortAdminPointToPoint object." REFERENCE "IEEE 802.1w clause 6.4.3, 6.5, 14.8.2" ::= { qtechRstpExtPortEntry 6 } qtechStpPortBpduGuard OBJECT-TYPE SYNTAX EnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION " The BPDU guard feature provides a secure response to invalid configurations because you must manually put the port back in service. Use the BPDU guard feature in a service-provider network to prevent an access port from participating in the spanning tree. When the port receives a BPDU, it is put in the error-disabled state if you enable BPDU guard feature of this port. " ::= { qtechRstpExtPortEntry 7 } qtechStpPortBpduFilter OBJECT-TYPE SYNTAX EnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "It will prevent the port from sending or receiving BPDUs if you enable BPDU filter feature of this port. " ::= { qtechRstpExtPortEntry 8 } qtechStpBpduGuard OBJECT-TYPE SYNTAX EnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "If you enable Global BPDU guard feature ,ports which is EdgePort will is put in the error-disabled state When thest ports receives a BPDU." ::= { qtechRstpMIBObjects 5 } qtechStpBpduFilter OBJECT-TYPE SYNTAX EnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "If you enable Global BPDU filter feature ,ports which is EdgePort will be prevented the port from sending or receiving BPDUs." ::= { qtechRstpMIBObjects 6 } --MSTP addition qtechStpCistRegionRoot OBJECT-TYPE SYNTAX BridgeId MAX-ACCESS read-only STATUS current DESCRIPTION "The Bridge Identifier of the current CIST Regional Root." REFERENCE "IEEE 802.1s-d14-1: Section 12.8.1.1.3" ::= { qtechRstpMIBObjects 7 } qtechStpCistPathCost OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The CIST path cost from the transmitting Bridge to the CIST Regional Root.." REFERENCE "IEEE 802.1s-d14-1: Section 12.8.1.1.3" ::= { qtechRstpMIBObjects 8 } --qtechStpPortCistTable OBJECT-TYPE -- SYNTAX SEQUENCE OF QtechStpPortCistEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "A table containing the spanning tree port path cost -- configuration when stpxSpanningTreePathCostMode is -- long(2), -- If the value of stpxSpanningTreePathCostMode is short(1), -- this table is not instantiated." -- ::= { qtechRstpMIBObjects 9 } --qtechStpPortCistEntry OBJECT-TYPE -- SYNTAX QtechStpPortCistEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "A conceptual row containing the spanning tree port path cost -- configuration." -- AUGMENTS { qtechRstpExtPortEntry } -- ::= { qtechStpPortCistTable 1 } --QtechStpPortCistEntry ::= SEQUENCE { -- qtechStpPortCistRegionRoot BridgeId, -- qtechStpPortCistPathCost Counter32 -- qtechStpPortHelloTime Integer32 --} --qtechStpPortCistRegionRoot OBJECT-TYPE -- SYNTAX BridgeId -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "The Bridge Identifier of the current CIST Regional Root." -- REFERENCE -- "IEEE 802.1s-d14-1: Section 12.8.2.1.3" -- ::= { qtechStpPortCistEntry 1} --qtechStpPortCistPathCost OBJECT-TYPE -- SYNTAX Counter32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "The CIST path cost from the transmitting Bridge to the CIST Regional Root." -- REFERENCE -- "IEEE 802.1s-d14-1: Section 12.8.2.1.3" -- ::= { qtechStpPortCistEntry 2} --qtechStpPortHelloTime OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "The administrative value of Hello Time for the Port." -- REFERENCE -- "IEEE 802.1s-d14-1: Section 12.8.2.1.3" -- ::= { qtechStpPortCistEntry 3} -- ------------------------------------------------------------- -- MSTP / MSTI 802.1s-d14-1 12.8.1 -- ------------------------------------------------------------- qtechStpMstiMaxInstanceNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum MST (Multiple Spanning Tree) instance id, that are supported by the device for the MST Protocol." ::= { qtechMstpMIBObjects 1} qtechStpMstiRegionName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "The operational MST region name." ::= { qtechMstpMIBObjects 2} qtechStpMstiRegionRevision OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The operational MST region version." ::= { qtechMstpMIBObjects 3 } qtechStpMstiMaxHopNumber OBJECT-TYPE SYNTAX Integer32 (1..40) MAX-ACCESS read-write STATUS current DESCRIPTION "The operational MST region max hop number." DEFVAL { 20 } ::= { qtechMstpMIBObjects 4 } qtechStpMstiInstanceTable OBJECT-TYPE SYNTAX SEQUENCE OF QtechStpMstiInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains MST instance information with one entry for each MST instance numbered from 0 to qtechStpxMSTMaxInstanceNumber." ::= {qtechMstpMIBObjects 5 } qtechStpMstiInstanceEntry OBJECT-TYPE SYNTAX QtechStpMstiInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A conceptual row containing the MST instance information." INDEX { qtechStpMstiInstanceIndex } ::= { qtechStpMstiInstanceTable 1 } QtechStpMstiInstanceEntry ::= SEQUENCE { qtechStpMstiInstanceIndex Integer32, qtechStpMstiInstanceVlansAddMapped OCTET STRING, qtechStpMstiInstanceVlansDeleteMapped OCTET STRING, qtechStpMstiInstanceVlansGetMapped OCTET STRING, qtechStpMstiInstanceRemainingHopCount Integer32, qtechStpMstiPriority Integer32, -- qtechStpMstiBridgeId Integer32, qtechStpMstiTimeSinceTopologyChange TimeTicks, qtechStpMstiTopChanges Integer32, -- qtechStpMstiTopChanged TruthValue, qtechStpMstiDesignatedRoot BridgeId, qtechStpMstiRootCost Integer32, qtechStpMstiRootPort Integer32, qtechStpMstiInstanceEntryStatus ConfigStatus } qtechStpMstiInstanceIndex OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "An integer that uniquely identifies an MST instance from 0 to the object value of qtechStpMstiMaxInstanceNumber." ::= {qtechStpMstiInstanceEntry 1 } qtechStpMstiInstanceVlansAddMapped OBJECT-TYPE SYNTAX OCTET STRING (SIZE (512)) MAX-ACCESS read-create STATUS current DESCRIPTION "A string of octets containing one bit per VLAN. The first octet corresponds to VLANs with VlanIndex values of 0 through 7; the second octet to VLANs 8 through 15; etc. The most significant bit of each octet corresponds to the lowest value VlanIndex in that octet. For each VLAN, if it is mapped to this MST instance, then the bit corresponding to that VLAN is set to '1'." ::= {qtechStpMstiInstanceEntry 2 } qtechStpMstiInstanceVlansDeleteMapped OBJECT-TYPE SYNTAX OCTET STRING (SIZE (512)) MAX-ACCESS read-create STATUS current DESCRIPTION "A string of octets containing one bit per VLAN. The first octet corresponds to VLANs with VlanIndex values of 0 through 7; the second octet to VLANs 8 through 15; etc. The most significant bit of each octet corresponds to the lowest value VlanIndex in that octet. For each VLAN, if it is mapped to this MST instance, then the bit corresponding to that VLAN is set to '1'." ::= {qtechStpMstiInstanceEntry 3 } qtechStpMstiInstanceVlansGetMapped OBJECT-TYPE SYNTAX OCTET STRING (SIZE (512)) MAX-ACCESS read-only STATUS current DESCRIPTION "A string of octets containing one bit per VLAN. The first octet corresponds to VLANs with VlanIndex values of 0 through 7; the second octet to VLANs 8 through 15; etc. The most significant bit of each octet corresponds to the lowest value VlanIndex in that octet. For each VLAN, if it is mapped to this MST instance, then the bit corresponding to that VLAN is set to '1'." ::= {qtechStpMstiInstanceEntry 4 } qtechStpMstiInstanceRemainingHopCount OBJECT-TYPE SYNTAX Integer32 (0..40) MAX-ACCESS read-only STATUS current DESCRIPTION "The remaining hop count for this MST instance." ::= {qtechStpMstiInstanceEntry 5 } qtechStpMstiPriority OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "The Bridge priority for the spanning tree instance identified by the MSTID." REFERENCE "IEEE 802.1s-d14-1: Section 12.8.1.2.3." DEFVAL { 32768 } ::= {qtechStpMstiInstanceEntry 6 } --qtechStpMstiBridgeId OBJECT-TYPE -- SYNTAX BridgeId -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "The Bridge Identifier for the spanning tree instance identified -- by the MSTID." -- REFERENCE -- "IEEE 802.1s-d14-1: Section 12.8.1.2.3." -- ::= {qtechStpMstiInstanceEntry 5 } qtechStpMstiTimeSinceTopologyChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Ccount in (in hundredths of a second) of the time elapsed since tcWhile (13.21) was last non-zero for any Port for the given MSTI." REFERENCE "IEEE 802.1s-d14-1: Section 12.8.1.2.3." ::= {qtechStpMstiInstanceEntry 7 } qtechStpMstiTopChanges OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Count of the times tcWhile (13.21) has been non-zero for any Port for the given MSTI since the Bridge was powered on or initialized." REFERENCE "IEEE 802.1s-d14-1: Section 12.8.1.2.3." ::= {qtechStpMstiInstanceEntry 8 } --qtechStpMstiTopChanged OBJECT-TYPE -- SYNTAX TruthValue -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "True if tcWhile is non-zero for any Port for the given MST." -- REFERENCE -- "IEEE 802.1s-d14-1: Section 12.8.1.2.3." -- ::= {qtechStpMstiInstanceEntry 8 } qtechStpMstiDesignatedRoot OBJECT-TYPE SYNTAX BridgeId MAX-ACCESS read-only STATUS current DESCRIPTION "The Bridge Identifier of the Root Bridge for the spanning tree instance identified by the MSTID." REFERENCE "IEEE 802.1s-d14-1: Section 12.8.1.2.3." ::= {qtechStpMstiInstanceEntry 9 } qtechStpMstiRootCost OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The path cost from the transmitting Bridge to the Root Bridge for the spanning tree instance identified by the MSTID." REFERENCE "IEEE 802.1s-d14-1: Section 12.8.1.2.3." ::= {qtechStpMstiInstanceEntry 10 } qtechStpMstiRootPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Root Port for the spanning tree instance identified by the MSTID." REFERENCE "IEEE 802.1s-d14-1: Section 12.8.1.2.3." ::= {qtechStpMstiInstanceEntry 11 } qtechStpMstiInstanceEntryStatus OBJECT-TYPE SYNTAX ConfigStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Status of this entry, set this object to valid will creat a entry, and set its value to invalid will delete this entry." ::= { qtechStpMstiInstanceEntry 12 } qtechStpPortMstiInstanceTable OBJECT-TYPE SYNTAX SEQUENCE OF QtechStpPortMstiInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains MST instance information with one entry for each MST instance numbered from 0 to qtechStpxMSTMaxInstanceNumber." ::= {qtechMstpMIBObjects 6 } qtechStpPortMstiInstanceEntry OBJECT-TYPE SYNTAX QtechStpPortMstiInstanceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A conceptual row containing pthe MST instance information of a bridge port." INDEX { qtechStpMstiInstanceIndex, qtechStpPortMstiIndex} ::= { qtechStpPortMstiInstanceTable 1 } QtechStpPortMstiInstanceEntry ::= SEQUENCE { qtechStpPortMstiIndex Integer32, -- qtechStpPortMstiUpTime TimeTicks, qtechStpPortMstiState INTEGER, -- qtechStpPortMstiEnable INTEGER, -- qtechStpPortMstiPortId OCTET STRING, qtechStpPortMstiAdminPathCost Integer32, qtechStpPortMstiOperPathCost Counter32, qtechStpPortMstiPriority Integer32, qtechStpPortMstiDesignatedRoot BridgeId, qtechStpPortMstiDesignatedCost Integer32, qtechStpPortMstiDesignatedBridge BridgeId, qtechStpPortMstiDesignatedPort OCTET STRING, qtechStpPortMstiPortRole INTEGER, qtechStpPortMstiPortForwardTransitions Integer32 } qtechStpPortMstiIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value of dot1dBasePort (i.e. dot1dBridge.1.4) for the bridge port." REFERENCE "dot1dBasePort is defined in RFC1493." ::= {qtechStpPortMstiInstanceEntry 1 } --qtechStpPortMstiUpTime OBJECT-TYPE -- SYNTAX TimeTicks -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "Count in seconds of the time elapsed since the Port was last reset or initialized." -- REFERENCE -- "IEEE 802.1s-d14-1: Section 12.8.2.2.3." -- ::= {qtechStpPortMstiInstanceEntry 2 } qtechStpPortMstiState OBJECT-TYPE SYNTAX INTEGER { disabled(1), blocking(2), listening(3), learning(4), forwarding(5), broken(6), discard(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the Port." REFERENCE "IEEE 802.1s-d14-1: Section 12.8.2.2.3." ::= {qtechStpPortMstiInstanceEntry 2 } --qtechStpPortMstiEnable OBJECT-TYPE -- SYNTAX INTEGER { -- enabled(1), -- disabled(2) -- } -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "The enabled/disabled status of the port." -- REFERENCE -- "IEEE 802.1s-d14-1: Section 12.8.2.2.3." -- ::= {qtechStpPortMstiInstanceEntry 3 } --qtechStpPortMstiPortId OBJECT-TYPE -- SYNTAX OCTET STRING (SIZE (2)) -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "The Port Identifier of the port on the Designated -- Bridge for this port's segment." -- REFERENCE -- "IEEE 802.1s-d14-1: Section 12.8.2.2.3." -- ::= {qtechStpPortMstiInstanceEntry 4 } qtechStpPortMstiAdminPathCost OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The contribution of this port to the path cost of paths towards the spanning tree root which include this port. 802.1D-1990 recommends that the default value of this parameter be in inverse proportion to the speed of the attached LAN. Setting this value to 0 indicates that port's real path cost will be automaticly assigned by system according to duplex and speed of the port.Setting this value to other value and system will assigned this value to the port." REFERENCE "IEEE 802.1s-d14-1: Section 12.8.2.2.3." ::= {qtechStpPortMstiInstanceEntry 3 } qtechStpPortMstiOperPathCost OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " Actual oper value of port cost of msti." REFERENCE "IEEE 802.1s-d14-1: Section 12.8.2.2.3." ::= {qtechStpPortMstiInstanceEntry 4 } qtechStpPortMstiPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the priority field which is contained in the first (in network byte order) octet of the (2 octet long) Port ID." REFERENCE "IEEE 802.1s-d14-1: Section 12.8.2.2.3." DEFVAL { 128 } ::= {qtechStpPortMstiInstanceEntry 5 } qtechStpPortMstiDesignatedRoot OBJECT-TYPE SYNTAX BridgeId MAX-ACCESS read-only STATUS current DESCRIPTION "The unique Bridge Identifier of the Bridge recorded as the Root." REFERENCE "IEEE 802.1s-d14-1: Section 12.8.2.2.3." ::= {qtechStpPortMstiInstanceEntry 6 } qtechStpPortMstiDesignatedCost OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The path cost of the Designated Port of the segment connected to this port." REFERENCE "IEEE 802.1s-d14-1: Section 12.8.2.2.3." ::= {qtechStpPortMstiInstanceEntry 7 } qtechStpPortMstiDesignatedBridge OBJECT-TYPE SYNTAX BridgeId MAX-ACCESS read-only STATUS current DESCRIPTION "The Bridge Identifier of the bridge which this port considers to be the Designated Bridge for this port's segment." REFERENCE "IEEE 802.1s-d14-1: Section 12.8.2.2.3." ::= {qtechStpPortMstiInstanceEntry 8 } qtechStpPortMstiDesignatedPort OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Port Identifier of the port on the Designated Bridge for this port's segment." REFERENCE "IEEE 802.1s-d14-1: Section 12.8.2.2.3." ::= {qtechStpPortMstiInstanceEntry 9 } qtechStpPortMstiPortRole OBJECT-TYPE SYNTAX INTEGER { disabledPort(1), alternatePort(2), backupPort(3), rootPort(4), designatedPort(5), masterPort(6) } MAX-ACCESS read-only STATUS current DESCRIPTION " Actual role of port in msti." ::= {qtechStpPortMstiInstanceEntry 10 } qtechStpPortMstiPortForwardTransitions OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times this port has transitioned from the Learning state to the Forwarding state in msti." ::= {qtechStpPortMstiInstanceEntry 11 } qtechStpMstiReset OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object allow of resetting MST configuration parameter reset to default settings. set its value to any but 0, will cause agent reset the parameters, set it to 0 will cause no action. this operation may cause some interval the station can not connect the agent depending on the parameters previous set." ::= { qtechMstpMIBObjects 7} qtechStpCistVlansAddMapped OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "A string of octets containing one bit per VLAN. The first octet corresponds to VLANs with VlanIndex values of 0 through 7; the second octet to VLANs 8 through 15; etc. The most significant bit of each octet corresponds to the lowest value VlanIndex in that octet. For each VLAN, if it is mapped to this MST instance, then the bit corresponding to that VLAN is set to '1'." ::= { qtechMstpMIBObjects 8 } qtechStpCistVlansGetMapped OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "A string of octets containing one bit per VLAN. The first octet corresponds to VLANs with VlanIndex values of 0 through 7; the second octet to VLANs 8 through 15; etc. The most significant bit of each octet corresponds to the lowest value VlanIndex in that octet. For each VLAN, if it is mapped to this MST instance, then the bit corresponding to that VLAN is set to '1'." ::= { qtechMstpMIBObjects 9 } qtechStpCistRemainingHopCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The remaining hop count for CIST." ::= { qtechMstpMIBObjects 10 } -- ------------------------------------------------------------- -- rstpMIB - Conformance Information -- ------------------------------------------------------------- stpExternConformance OBJECT IDENTIFIER ::= { qtechStpMIB 4 } stpExternGroups OBJECT IDENTIFIER ::= { stpExternConformance 1 } -- stpExternCompliances OBJECT IDENTIFIER ::= { stpExternConformance 2 } -- ------------------------------------------------------------- -- Units of conformance -- ------------------------------------------------------------- stpExternGroup OBJECT-GROUP OBJECTS { qtechSysStpStatus, qtechSysStpReset, qtechStpPortIfIndex, qtechStpPortAdminPathCost, qtechStpPortOperPathCost, qtechStpPortRole -- qtechStpPortIfRunSTP } STATUS current DESCRIPTION "Spanning Tree extern information for the bridge." ::= { stpExternGroups 1 } -- ------------------------------------------------------------- -- Compliance statements -- ------------------------------------------------------------- --stpExternCompliance MODULE-COMPLIANCE -- STATUS current -- DESCRIPTION -- "The compliance statement for device support of bridging -- services." -- -- MODULE -- MANDATORY-GROUPS { -- stpExternGroup -- } -- OBJECT dot1dStpPortPathCost -- MIN-ACCESS read-only -- DESCRIPTION "Write access is not required." -- -- OBJECT dot1dStpPortEnable -- MIN-ACCESS read-only -- DESCRIPTION "Write access is not required." -- -- OBJECT dot1dStpHoldTime -- MIN-ACCESS not-accessible -- DESCRIPTION "Access is not required." -- -- OBJECT dot1dStpPortState -- SYNTAX INTEGER { -- disabled(1), -- blocking(2), -- listening(3), -- learning(4), -- forwarding(5), -- broken(6), -- discard(7) -- } -- DESCRIPTION "Add a new syntax." -- -- ::= { stpExternCompliances 1 } -- ------------------------------------------------------------- -- rstpMIB - Conformance Information -- ------------------------------------------------------------- rstpConformance OBJECT IDENTIFIER ::= { qtechStpMIB 5 } rstpGroups OBJECT IDENTIFIER ::= { rstpConformance 1 } rstpCompliances OBJECT IDENTIFIER ::= { rstpConformance 2 } -- ------------------------------------------------------------- -- Units of conformance -- ------------------------------------------------------------- rstpBridgeGroup OBJECT-GROUP OBJECTS { qtechStpVersion, qtechStpTxHoldCount, qtechStpBpduGuard, qtechStpBpduFilter } STATUS current DESCRIPTION "Rapid Spanning Tree information for the bridge." ::= { rstpGroups 1 } rstpDefaultPathCostGroup OBJECT-GROUP OBJECTS { qtechStpPathCostDefault } STATUS current DESCRIPTION "Default Spanning Tree path cost information." ::= { rstpGroups 2 } rstpPortGroup OBJECT-GROUP OBJECTS { qtechRstpExtPortIfIndex, qtechStpPortProtocolMigration, qtechStpPortAdminEdgePort, qtechStpPortOperEdgePort, qtechStpPortAdminPointToPoint, qtechStpPortOperPointToPoint, qtechStpPortBpduGuard, qtechStpPortBpduFilter, -- qtechStpPortCistRegionRoot, -- qtechStpPortCistPathCost, -- qtechStpPortHelloTime, qtechStpCistRegionRoot, qtechStpCistPathCost } STATUS current DESCRIPTION "Rapid Spanning Tree information for individual ports." ::= { rstpGroups 3 } -- ------------------------------------------------------------- -- Compliance statements -- ------------------------------------------------------------- rstpCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for device support of bridging services." MODULE MANDATORY-GROUPS { rstpBridgeGroup, rstpDefaultPathCostGroup, rstpPortGroup } GROUP rstpDefaultPathCostGroup DESCRIPTION "Support for this group is mandatory only if both 16-bit and 32-bit Path Costs are supported." ::= { rstpCompliances 1 } -- ------------------------------------------------------------- -- mstpMIB - Conformance Information -- ------------------------------------------------------------- mstpConformance OBJECT IDENTIFIER ::= { qtechStpMIB 6 } mstpGroups OBJECT IDENTIFIER ::= { mstpConformance 1 } mstpCompliances OBJECT IDENTIFIER ::= { mstpConformance 2 } -- ------------------------------------------------------------- -- Units of conformance -- ------------------------------------------------------------- mstpBridgeRegionGroup OBJECT-GROUP OBJECTS { qtechStpMstiMaxInstanceNumber, qtechStpMstiRegionName, qtechStpMstiRegionRevision, qtechStpMstiMaxHopNumber } STATUS current DESCRIPTION "Msti information for the bridge." ::= { mstpGroups 1 } mstpMstiBridgeGroup OBJECT-GROUP OBJECTS { qtechStpMstiInstanceIndex, qtechStpMstiInstanceVlansAddMapped, qtechStpMstiInstanceVlansDeleteMapped, qtechStpMstiInstanceVlansGetMapped, qtechStpMstiInstanceRemainingHopCount, qtechStpMstiPriority, -- qtechStpMstiBridgeId, qtechStpMstiTimeSinceTopologyChange, qtechStpMstiTopChanges, -- qtechStpMstiTopChanged, qtechStpMstiDesignatedRoot, qtechStpMstiRootCost, qtechStpMstiRootPort, qtechStpMstiInstanceEntryStatus } STATUS current DESCRIPTION "Default Spanning Tree path cost information." ::= { mstpGroups 2 } mstpMstiPortGroup OBJECT-GROUP OBJECTS { -- qtechStpPortMstiUpTime, qtechStpPortMstiState, -- qtechStpPortMstiEnable, -- qtechStpPortMstiPortId, qtechStpPortMstiAdminPathCost, qtechStpPortMstiOperPathCost, qtechStpPortMstiPriority, qtechStpPortMstiDesignatedRoot, qtechStpPortMstiDesignatedCost, qtechStpPortMstiDesignatedBridge, qtechStpPortMstiDesignatedPort, qtechStpPortMstiPortRole, qtechStpPortMstiPortForwardTransitions } STATUS current DESCRIPTION "Rapid Spanning Tree information for individual ports." ::= { mstpGroups 3 } -- ------------------------------------------------------------- -- Compliance statements -- ------------------------------------------------------------- mstpCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for device support of bridging services." MODULE MANDATORY-GROUPS { mstpBridgeRegionGroup, mstpMstiBridgeGroup, mstpMstiPortGroup } ::= { mstpCompliances 1 } END