-- This file was included in WWP MIB release 04-10-01-0027 -- -- WWP-LEOS-RSTP-MIB.my -- -- WWP-LEOS-RSTP-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI TruthValue, RowStatus, TEXTUAL-CONVENTION, DisplayString, MacAddress FROM SNMPv2-TC dot1dStpPort FROM BRIDGE-MIB dot1dStpPortOperEdgePort FROM RSTP-MIB wwpModules, wwpModulesLeos FROM WWP-SMI; wwpLeosRstpMIB MODULE-IDENTITY LAST-UPDATED "201108020000Z" ORGANIZATION "Ciena, Inc" CONTACT-INFO " Mib Meister 115 North Sullivan Road Spokane Valley, WA 99037 USA Phone: +1 509 242 9000 Email: support@ciena.com" DESCRIPTION "Deprecated wwpLeosRstpPvstBpduReceivedNotification." REVISION "201108020000Z" DESCRIPTION "The MIB module for the WWP RstpMib specific information." REVISION "200104031700Z" DESCRIPTION "Initial creation." ::= { wwpModulesLeos 13 } -- -- Node definitions -- wwpLeosRstpMIBObjects OBJECT IDENTIFIER ::= { wwpLeosRstpMIB 1 } wwpLeosRstpDomain OBJECT IDENTIFIER ::= { wwpLeosRstpMIBObjects 1 } wwpLeosRstpPortExt OBJECT IDENTIFIER ::= { wwpLeosRstpMIBObjects 2 } wwpLeosRstpLocalPortExt OBJECT IDENTIFIER ::= { wwpLeosRstpMIBObjects 3 } -- Notifications wwpLeosRstpMIBNotificationPrefix OBJECT IDENTIFIER ::= { wwpLeosRstpMIB 2 } wwpLeosRstpMIBNotifications OBJECT IDENTIFIER ::= { wwpLeosRstpMIBNotificationPrefix 0 } -- Conformance information wwpLeosRstpMIBConformance OBJECT IDENTIFIER ::= { wwpLeosRstpMIB 3 } wwpLeosRstpMIBCompliances OBJECT IDENTIFIER ::= { wwpLeosRstpMIBConformance 1 } wwpLeosRstpMIBGroups OBJECT IDENTIFIER ::= { wwpLeosRstpMIBConformance 2 } wwpLeosRstpMode OBJECT-TYPE SYNTAX INTEGER { unknown(1), rstp(2), domain(3), mstp(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object sets the mode to rstp, domain, or mstp mode. If the selected mode is not supported by the device, an SNMP error will be returned and the value of this object will remain unchanged." ::= { wwpLeosRstpDomain 1 } wwpLeosRstpDomainTable OBJECT-TYPE SYNTAX SEQUENCE OF WwpLeosRstpDomainEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Rstp Domain." ::= { wwpLeosRstpDomain 2 } wwpLeosRstpDomainEntry OBJECT-TYPE SYNTAX WwpLeosRstpDomainEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Rstp domain entry in the rstp domain table." INDEX { wwpLeosRstpDomainId } ::= { wwpLeosRstpDomainTable 1 } WwpLeosRstpDomainEntry ::= SEQUENCE { wwpLeosRstpDomainId INTEGER, wwpLeosRstpDomainName DisplayString, wwpLeosRstpDomainStatus RowStatus } wwpLeosRstpDomainId OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Domain Id used as an index in the rstp domain. Domain id starts at 0." ::= { wwpLeosRstpDomainEntry 1 } wwpLeosRstpDomainName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "The name of the domain." ::= { wwpLeosRstpDomainEntry 2 } wwpLeosRstpDomainStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "To create a row in this table, the snmp manager must set this object to 'createAndGo'. To delete the entry set it to delete." ::= { wwpLeosRstpDomainEntry 3 } -- -- RSTP Port Membership table -- wwpLeosRstpDomainMemTable OBJECT-TYPE SYNTAX SEQUENCE OF WwpLeosRstpDomainMemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Rstp Domain." ::= { wwpLeosRstpDomain 3 } wwpLeosRstpDomainMemEntry OBJECT-TYPE SYNTAX WwpLeosRstpDomainMemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Rstp domain member entry." INDEX { wwpLeosRstpDomainId, wwpLeosRstpDomainPortId} ::= { wwpLeosRstpDomainMemTable 1 } WwpLeosRstpDomainMemEntry ::= SEQUENCE { wwpLeosRstpDomainPortId INTEGER, wwpLeosRstpDomainMemStatus RowStatus } wwpLeosRstpDomainPortId OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Port ID for the instance. Port ID's start at 1, and may not be consecutive for each additional port. This port Id should refer to the dot1dBasePort in the Dot1dBasePortEntry." ::= { wwpLeosRstpDomainMemEntry 1 } wwpLeosRstpDomainMemStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "To add a port to the domain create a row in this table, by setting this object to 'createAndGo'. To remove the port from the domain set this object to delete." ::= { wwpLeosRstpDomainMemEntry 2 } -- -- RSTP domain attributes table table -- wwpLeosRstpBridgeDomainAttrs OBJECT IDENTIFIER ::= { wwpLeosRstpDomain 4 } wwpLeosRstpDomainAttrsForceVer OBJECT-TYPE SYNTAX INTEGER { stp(0), notDefined(1), rstp(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute specifies the domain version to rstp or stp." ::= { wwpLeosRstpBridgeDomainAttrs 1 } wwpLeosRstpDomainAttrsForwardDelay OBJECT-TYPE SYNTAX INTEGER (4..30) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute specifies the forward delay for rstp domain." ::= { wwpLeosRstpBridgeDomainAttrs 2 } wwpLeosRstpDomainAttrsHelloTime OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute specifies the hello time for the rstp domain." ::= { wwpLeosRstpBridgeDomainAttrs 3 } wwpLeosRstpDomainAttrsLoopBackBlock OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies if loopback port blocking feature is enabled/disabled." ::= { wwpLeosRstpBridgeDomainAttrs 4 } wwpLeosRstpDomainAttrsMaxAge OBJECT-TYPE SYNTAX INTEGER (6..40) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the max age time for the rstp domain." ::= { wwpLeosRstpBridgeDomainAttrs 5 } wwpLeosRstpDomainAttrsPathCostDef OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the path cost. if it is 1 then it is 8021d else it is 8021t." ::= { wwpLeosRstpBridgeDomainAttrs 6 } wwpLeosRstpDomainAttrsPriority OBJECT-TYPE SYNTAX INTEGER (0..15) MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object will set the rstp domain priority." ::= { wwpLeosRstpBridgeDomainAttrs 7 } wwpLeosRstpDomainAttrsTxHoldCount OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the tx hold count for a domain." ::= { wwpLeosRstpBridgeDomainAttrs 8 } -- -- Domain Attributes -- wwpLeosRstpDomainAttrTable OBJECT-TYPE SYNTAX SEQUENCE OF WwpLeosRstpDomainAttrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of each Rstp Domain." ::= { wwpLeosRstpDomain 5 } wwpLeosRstpDomainAttrEntry OBJECT-TYPE SYNTAX WwpLeosRstpDomainAttrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Rstp domain attributes entry." INDEX { wwpLeosRstpDomainId } ::= { wwpLeosRstpDomainAttrTable 1 } WwpLeosRstpDomainAttrEntry ::= SEQUENCE { wwpLeosRstpDomainAttrDesignatedBridgePri INTEGER, wwpLeosRstpDomainAttrDesignatedBridgeMac MacAddress, wwpLeosRstpDomainAttrDesignatedRootPri INTEGER, wwpLeosRstpDomainAttrDesignatedRootMac MacAddress, wwpLeosRstpDomainAttrRootCost INTEGER, wwpLeosRstpDomainAttrRootPort INTEGER, wwpLeosRstpDomainAttrMaxAge INTEGER, wwpLeosRstpDomainAttrHelloTime INTEGER, wwpLeosRstpDomainAttrHoldTime INTEGER, wwpLeosRstpDomainAttrForwardDelay INTEGER, wwpLeosRstpDomainAttrPriority INTEGER } wwpLeosRstpDomainAttrDesignatedBridgePri OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute specifies the designated bridge priority for specified domain. This attribute represents the first two octets of the (8 octet long) designated bridge ID. The writable portion of these two octets is the first 3 bits starting from least significant bit." ::= { wwpLeosRstpDomainAttrEntry 1 } wwpLeosRstpDomainAttrDesignatedBridgeMac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute specifies the designated bridge mac address for specified domain." ::= { wwpLeosRstpDomainAttrEntry 2 } wwpLeosRstpDomainAttrDesignatedRootPri OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute specifies the designated root priority for specified domain. This attribute represents the first two octets of the (8 octet long) designated root bridge ID. The writable portion of these two octets is the first 3 bits starting from least significant bit." ::= { wwpLeosRstpDomainAttrEntry 3 } wwpLeosRstpDomainAttrDesignatedRootMac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute specifies the designated root mac address for specified domain." ::= { wwpLeosRstpDomainAttrEntry 4 } wwpLeosRstpDomainAttrRootCost OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute specifies the root cost for specified domain." ::= { wwpLeosRstpDomainAttrEntry 5 } wwpLeosRstpDomainAttrRootPort OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute specifies the designated port for specified domain." ::= { wwpLeosRstpDomainAttrEntry 6 } wwpLeosRstpDomainAttrMaxAge OBJECT-TYPE SYNTAX INTEGER (6..40) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute specifies the max age for specified domain." ::= { wwpLeosRstpDomainAttrEntry 7 } wwpLeosRstpDomainAttrHelloTime OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute specifies the hello time for specified domain." ::= { wwpLeosRstpDomainAttrEntry 8 } wwpLeosRstpDomainAttrHoldTime OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute specifies the hold time for specified domain." ::= { wwpLeosRstpDomainAttrEntry 9 } wwpLeosRstpDomainAttrForwardDelay OBJECT-TYPE SYNTAX INTEGER (4..30) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute specifies the forward delay for specified domain." ::= { wwpLeosRstpDomainAttrEntry 10 } wwpLeosRstpDomainAttrPriority OBJECT-TYPE SYNTAX INTEGER (0..15) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute specifies the domain priority for given domain." ::= { wwpLeosRstpDomainAttrEntry 11 } -- -- Rstp Max Age Event Interval -- wwpLeosRstpMaxAgeEventInterval OBJECT-TYPE SYNTAX INTEGER (60..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines how often the events relating to Max Age BPDU's being Sent or Received will be generated. It is the number of seconds that must pass between events." ::= { wwpLeosRstpDomain 6 } -- -- Rstp PortInfo -- wwpLeosRstpPortInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF WwpLeosRstpPortInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table that contains additional information about each port. This table is extension of dot1dStpPortTable." ::= { wwpLeosRstpPortExt 1 } wwpLeosRstpPortInfoEntry OBJECT-TYPE SYNTAX WwpLeosRstpPortInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Rstp port information entry." INDEX { wwpLeosRstpPortId } ::= { wwpLeosRstpPortInfoTable 1 } WwpLeosRstpPortInfoEntry ::= SEQUENCE { wwpLeosRstpPortId INTEGER, wwpLeosRstpPortDesiginatedId MacAddress, wwpLeosRstpPortDesiginatedPid OCTET STRING, wwpLeosRstpPortDynPathCostState INTEGER } wwpLeosRstpPortId OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the port num used as index in the table. Value of this port id is same as dot1dStpPort." ::= { wwpLeosRstpPortInfoEntry 1 } wwpLeosRstpPortDesiginatedId OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute specifies the designated id for the given port." ::= { wwpLeosRstpPortInfoEntry 2 } wwpLeosRstpPortDesiginatedPid OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute specifies the designated id for the given port." ::= { wwpLeosRstpPortInfoEntry 3 } -- -- Rstp Ext PortInfo -- wwpLeosRstpLocalPortInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF WwpLeosRstpLocalPortInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table that contains additional local information about each port. This table is also extension of dot1dStpPortTable." ::= { wwpLeosRstpLocalPortExt 1 } wwpLeosRstpLocalPortInfoEntry OBJECT-TYPE SYNTAX WwpLeosRstpLocalPortInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Rstp local port information entry." INDEX { wwpLeosRstpPortId } ::= { wwpLeosRstpLocalPortInfoTable 1 } WwpLeosRstpLocalPortInfoEntry ::= SEQUENCE { wwpLeosRstpPortDynPathCostState INTEGER } wwpLeosRstpPortDynPathCostState OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute enable | disable dynamic path cost for the given port. Before setting dot1dStpPortPathCost user must set wwpLeosRstpPortDynPathCostState = disabled." ::= { wwpLeosRstpLocalPortInfoEntry 1 } -- -- Notifications -- wwpLeosRstpPortBackupNotification NOTIFICATION-TYPE OBJECTS { dot1dStpPort } STATUS current DESCRIPTION "A wwpLeosRstpPortBackupNotification is sent whenever device detects self loop i.e. same cable connected to two ports on the same device." ::= { wwpLeosRstpMIBNotifications 1 } wwpLeosRstpPvstBpduReceivedNotification NOTIFICATION-TYPE OBJECTS { dot1dStpPort } STATUS deprecated DESCRIPTION "A wwpLeosRstpPvstBpduReceivedNotification is sent whenever PVST BPDU is received on the port. This trap is sent out every minute." ::= { wwpLeosRstpMIBNotifications 2 } wwpLeosRstpSelfLoopNotification NOTIFICATION-TYPE OBJECTS { dot1dStpPort } STATUS current DESCRIPTION "A wwpLeosRstpSelfLoopNotification is sent whenever device detects same cable connected to a port in a loop back. Also if loop-back blocking is enabled on the device then rstp will block this port (self disable)." ::= { wwpLeosRstpMIBNotifications 3 } wwpLeosRstpPortOperEdgeNotification NOTIFICATION-TYPE OBJECTS { dot1dStpPort, dot1dStpPortOperEdgePort } STATUS current DESCRIPTION "A wwpLeosRstpPortOperEdgeNotification trap is sent whenever device detects a port Rstp OperEdge change." ::= { wwpLeosRstpMIBNotifications 4 } wwpLeosRstpPortFlapNotification NOTIFICATION-TYPE OBJECTS { dot1dStpPort } STATUS current DESCRIPTION "A wwpLeosRstpPortFlapNotification trap is sent whenever device detects a port flapping. Trap is generated under following criteria. If device detects port flapped more than once within 1 minute timer period and it has not sent trap within last 5 minutes then it will generate this trap." ::= { wwpLeosRstpMIBNotifications 5 } wwpLeosRstpBridgeRootPortLostNotification NOTIFICATION-TYPE OBJECTS { dot1dStpPort } STATUS current DESCRIPTION "A wwpLeosRstpBridgeRootPortLostNotification trap is sent whenever device detects that bridge root port is lost. This trap will indicate either the link failure or link partner RSTP disabled." ::= { wwpLeosRstpMIBNotifications 6 } END -- -- WWP-RSTP-MIB --