ARRIS-HOT-PROTECTION-MODE-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32 FROM SNMPv2-SMI arrisProdIdCM FROM ARRIS-MIB; arrisHorizOvertempProtModeMib MODULE-IDENTITY LAST-UPDATED "201410010000Z" -- October 1, 2014 ORGANIZATION "ARRIS Broadband" CONTACT-INFO "ARRIS Postal: ARRIS Broadband 3871 Lakefield Drive Suite 300 Suwanee, GA 30024-1242 U.S.A. Phone: E-mail: " DESCRIPTION "This MIB module supplies the basic management objects for the Horizontal Over-Temperature feature." -- Revision history REVISION "201409050000Z" -- September 05, 2014 DESCRIPTION "First release of ARRIS Horizontal Over-Temperature Protection Mode MIB." REVISION "201409240000Z" -- September 24, 2014 DESCRIPTION "Corrected arrisHorizOvertempProtModeCount SYNTAX and DESCRIPTION, and updated default value of arrisHorizOvertempProtModeNormalOpRecoveryTemp." REVISION "201410010000Z" -- October 1, 2014 DESCRIPTION "Added Counter32 to IMPORTS, modified mib file DESCRIPTION, defined arrisProdIdCM leaf to 16, and defined a valid range from 15 to 65 for all temperature thresholds" ::= { arrisProdIdCM 16 } arrisHorizOvertempProtModeMibObjects OBJECT IDENTIFIER ::= { arrisHorizOvertempProtModeMib 1 } arrisHorizOvertempProtModeMonitoring OBJECT IDENTIFIER ::= { arrisHorizOvertempProtModeMibObjects 1 } arrisHorizOvertempProtModeConfiguration OBJECT IDENTIFIER ::= { arrisHorizOvertempProtModeMibObjects 2 } arrisHorizOvertempProtModeState OBJECT-TYPE SYNTAX INTEGER { normal(1), thresholdExceededHOTPTier1(2), thresholdExceededHOTPTier2(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current thermal state. The value 'normal(1)' indicates the device is operating within the normal temperature range and not running in Horizontal Over-Temperature Protection Mode. The value 'thresholdExceededHOTPTier1(2)' indicates the device exceeded the maximum normal operating temperature and is in Tier 1 Horizontal Over-Temperature Protection Mode. The value 'thresholdExceededHOTPTier2(3)' indicates the device exceeded the maximum Tier 1 operating temperature and is in Tier 2 Horizontal Over-Temperature Protection Mode." ::= { arrisHorizOvertempProtModeMonitoring 1 } arrisHorizOvertempProtModeCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the number of times the device has exceeded the maximum temperature threshold and gone into Tier2 Horizontal Over-Temperature Protection Mode. This value is persistent and only cleared by a restore to factory defaults." ::= { arrisHorizOvertempProtModeMonitoring 2 } arrisHorizOvertempProtModeTier1MinThreshold OBJECT-TYPE SYNTAX Integer32 (15..65) MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum temperature in Celcius that triggers device to switch from normal operation to Tier 1 Over-Temperature Protection Mode operation." DEFVAL { 37 } ::= { arrisHorizOvertempProtModeConfiguration 1 } arrisHorizOvertempProtModeTier1MaxThreshold OBJECT-TYPE SYNTAX Integer32 (15..65) MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum temperature in Celcius that the device continues to operate in Tier 1 Over-Temperature Protection Mode before switching to Tier 2 Over-Temperature Protection Mode operation." DEFVAL { 47 } ::= { arrisHorizOvertempProtModeConfiguration 2 } arrisHorizOvertempProtModeNormalOpRecoveryTemp OBJECT-TYPE SYNTAX Integer32 (15..65) MAX-ACCESS read-write STATUS current DESCRIPTION "Temperature in Celcius that the device recovers back to normal operation after being in Tier 1 Over-Temperature Protection Mode." DEFVAL { 33 } ::= { arrisHorizOvertempProtModeConfiguration 3 } END