@ -174,4 +174,285 @@ IMPORTS
""
::= { oaDCPowerEntry 4 }
oaVendorExtend OBJECT IDENTIFIER ::= { oaIdent 8 }
AdminEDFAIP OBJECT IDENTIFIER ::= { oaVendorExtend 13 }
edfaIPNetTabNum OBJECT IDENTIFIER ::= { AdminEDFAIP 1 }
edfaIPTable OBJECT IDENTIFIER ::= { AdminEDFAIP 2 }
oaPumpNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 1 }
oaOutputPowerSet OBJECT-TYPE
SYNTAX INTEGER ( 0..4000 )
ACCESS read-write
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 2 }
oaOutputPowerSetValueMax OBJECT-TYPE
SYNTAX INTEGER ( 0..4000 )
ACCESS read-only
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 3 }
oaOutputPowerSetValueMin OBJECT-TYPE
SYNTAX INTEGER ( 0..4000 )
ACCESS read-only
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 4 }
oaFansState OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2)}
ACCESS read-only
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 5 }
oaFansControl OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2), auto(3) }
ACCESS read-write
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 6 }
oaInputOpticalPower2 OBJECT-TYPE
SYNTAX INTEGER ( -2000..2000 )
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { oaVendorExtend 7 }
oaOpticalOutputNum OBJECT-TYPE
SYNTAX INTEGER ( -128..127 )
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { oaVendorExtend 8 }
oaABControl OBJECT-TYPE
SYNTAX INTEGER { Auto(1), M(2)}
ACCESS read-only
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 9 }
oaDSControl OBJECT-TYPE
SYNTAX INTEGER { CH(1), CH(2)}
ACCESS read-only
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 10 }
oaABState OBJECT-TYPE
SYNTAX INTEGER { CH(1), CH(2)}
ACCESS read-only
STATUS optional
DESCRIPTION ""
::= { oaVendorExtend 11 }
oaEDFAAlarmRangeTable OBJECT-TYPE
SYNTAX SEQUENCE OF OaEDFAAlarmRangeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { oaVendorExtend 12 }
oaEDFAAlarmRangeEntry OBJECT-TYPE
SYNTAX OaEDFAAlarmRangeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { oaEDFAAlarmRangeIndex }
::= { oaEDFAAlarmRangeTable 1 }
OaEDFAAlarmRangeEntry ::=
SEQUENCE {
oaEDFAAlarmRangeIndex
INTEGER,
oaEDFAAlarmRangeDecr
OCTET STRING,
oaEDFAAlarmRangeHIHItoHI
INTEGER,
oaEDFAAlarmRangeHIHItoLO
INTEGER,
oaEDFAAlarmRangeHItoHI
INTEGER,
oaEDFAAlarmRangeHItoLO
INTEGER,
oaEDFAAlarmRangeLOtoHI
INTEGER,
oaEDFAAlarmRangeLOtoLO
INTEGER,
oaEDFAAlarmRangeLOLOtoHI
INTEGER,
oaEDFAAlarmRangeLOLOtoLO
INTEGER,
oaEDFAAlarmRangeDDtoHI
INTEGER,
oaEDFAAlarmRangeDDtoLO
INTEGER
}
oaEDFAAlarmRangeIndex OBJECT-TYPE
SYNTAX INTEGER (1..12)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 1 }
oaEDFAAlarmRangeDecr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 2 }
oaEDFAAlarmRangeHIHItoHI OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 3 }
oaEDFAAlarmRangeHIHItoLO OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 4 }
oaEDFAAlarmRangeHItoHI OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 5 }
oaEDFAAlarmRangeHItoLO OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 6 }
oaEDFAAlarmRangeLOtoHI OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 7 }
oaEDFAAlarmRangeLOtoLO OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 8 }
oaEDFAAlarmRangeLOLOtoHI OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 9 }
oaEDFAAlarmRangeLOLOtoLO OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 10 }
oaEDFAAlarmRangeDDtoHI OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 11 }
oaEDFAAlarmRangeDDtoLO OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { oaEDFAAlarmRangeEntry 12 }
edfaIPNetTabNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { AdminEDFAIP 1 }
edfaIPTable OBJECT-TYPE
SYNTAX SEQUENCE OF EdfaNetIPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
::= { AdminEDFAIP 2 }
EdfaNetIPEntry OBJECT-TYPE
SYNTAX EdfaNetIPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION ""
INDEX { MachineNetIpIndex }
::= { edfaIPTable 1 }
EdfaNetIPEntry ::=
SEQUENCE
{
MachineNetIpIndex
INTEGER,
MachineNetIpDecr
DisplayString,
MachineNetIpMessg
IpAddress
}
MachineNetIpIndex OBJECT-TYPE
SYNTAX INTEGER ( 0..10 )
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { EdfaNetIPEntry 1 }
MachineNetIpDecr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { EdfaNetIPEntry 2 }
MachineNetIpMessg OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION ""
::= { EdfaNetIPEntry 3 }
END