commit version 22.12.12447
This commit is contained in:
@ -21,14 +21,26 @@ IMPORTS
|
||||
|
||||
|
||||
netPing MODULE-IDENTITY
|
||||
LAST-UPDATED "201411210000Z"
|
||||
LAST-UPDATED "201601140000Z"
|
||||
ORGANIZATION "NetPing East, Alentis Electronics"
|
||||
CONTACT-INFO
|
||||
"developers@netping.ru"
|
||||
DESCRIPTION
|
||||
"Generic MIB for NetPing remote sensing and control"
|
||||
|
||||
REVISION "201601140000Z"
|
||||
DESCRIPTION
|
||||
"npIrStatus values changed"
|
||||
|
||||
REVISION "201509240000Z"
|
||||
DESCRIPTION
|
||||
"npElecMeter branch added"
|
||||
|
||||
REVISION "201411210000Z"
|
||||
REVISION "201504090000Z"
|
||||
DESCRIPTION
|
||||
"npRelHumTrap added; npIoTrapLevelLegend added"
|
||||
|
||||
REVISION "201411210000Z"
|
||||
DESCRIPTION
|
||||
"npRelayFlip variable max-access bugfix"
|
||||
|
||||
@ -518,11 +530,19 @@ npIoTrapMemo OBJECT-TYPE
|
||||
DESCRIPTION "Trap data, IO line memo"
|
||||
::= { npIoTraps 6 }
|
||||
|
||||
npIoTrapLevelLegend OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Legend for current logic level on the IO line"
|
||||
::= { npIoTraps 7 }
|
||||
|
||||
npIoTrap NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
npIoTrapLineN,
|
||||
npIoTrapLevelIn,
|
||||
npIoTrapMemo
|
||||
npIoTrapMemo,
|
||||
npIoTrapLevelLegend
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
@ -741,8 +761,24 @@ npRelHumSensorValueT100 OBJECT-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Sensor temperature, deg.C * 100 (fixed point two decimal places)
|
||||
Used to get access to the fractional part of T value"
|
||||
::= { npRelHumSensor 9 }
|
||||
|
||||
::= { npRelHumSensor 9 }
|
||||
|
||||
npRelHumTraps OBJECT IDENTIFIER::={npRelHumidity 9}
|
||||
npRelHumTrapPrefix OBJECT IDENTIFIER::={npRelHumTraps 0}
|
||||
|
||||
npRelHumTrap NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
npRelHumSensorStatusH,
|
||||
npRelHumSensorValueH,
|
||||
npRelHumSafeRangeHigh,
|
||||
npRelHumSafeRangeLow
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Status of Relative Humidity RH sensor has changed!"
|
||||
::= { npRelHumTrapPrefix 1 }
|
||||
|
||||
|
||||
|
||||
npIr OBJECT IDENTIFIER::={lightcom 7900}
|
||||
npIrCtrl OBJECT IDENTIFIER::={npIr 1}
|
||||
@ -764,16 +800,83 @@ npIrReset OBJECT-TYPE
|
||||
|
||||
npIrStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
ok (0),
|
||||
busyCaptureWaitingButton (1),
|
||||
busyCaptureWaitingIr (2),
|
||||
busyPlayback (3),
|
||||
error (255)
|
||||
commandCompleted (0),
|
||||
protocolError (1),
|
||||
commandAccepted (2),
|
||||
errorUnknown (16),
|
||||
errorBadNumber (17),
|
||||
errorEmptyRecord (18),
|
||||
errorFlashChip (19),
|
||||
errorTimeout (20),
|
||||
errorExtBusBusy (21)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "IR transiever status"
|
||||
::= { npIrCtrl 3 }
|
||||
|
||||
|
||||
|
||||
npElecMeter OBJECT IDENTIFIER::={lightcom 9700}
|
||||
|
||||
npElecTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF NpElecEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "Electricity Meter Table"
|
||||
::= { npElecMeter 1 }
|
||||
|
||||
npElecEntry OBJECT-TYPE
|
||||
SYNTAX NpElecEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "Electricity Meter Table Table Row"
|
||||
INDEX { npElecIndex }
|
||||
::= { npElecTable 1 }
|
||||
|
||||
NpElecEntry ::= SEQUENCE {
|
||||
npElecIndex INTEGER,
|
||||
npElecPulsesPerKwh INTEGER,
|
||||
npElecPower Gauge32,
|
||||
npElecEnergy Counter32,
|
||||
npElecEnergy100 Counter32
|
||||
}
|
||||
|
||||
npElecIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..4)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Number of elec.meter, associated with IO line"
|
||||
::= { npElecEntry 1 }
|
||||
|
||||
npElecPulsesPerKwh OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Pulses on IO line input per 1 kWh of consumed energy"
|
||||
::= { npElecEntry 2 }
|
||||
|
||||
npElecPower OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Power, Watts, based on pulse rate/interval, 5 minute average"
|
||||
::= { npElecEntry 3 }
|
||||
|
||||
npElecEnergy OBJECT-TYPE
|
||||
SYNTAX Counter32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Energy counter, kWh, based on pulse count"
|
||||
::= { npElecEntry 4 }
|
||||
|
||||
npElecEnergy100 OBJECT-TYPE
|
||||
SYNTAX Counter32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Energy counter, kWh*100, based on pulse count"
|
||||
::= { npElecEntry 5 }
|
||||
|
||||
|
||||
|
||||
npReboot OBJECT IDENTIFIER::={ lightcom 911 }
|
||||
|
Reference in New Issue
Block a user