commit version 22.12.12447

This commit is contained in:
2023-01-01 22:36:12 -05:00
parent af1b03d79f
commit b948283a96
744 changed files with 620715 additions and 27381 deletions

View File

@ -21,14 +21,26 @@ IMPORTS
netPing MODULE-IDENTITY
LAST-UPDATED "201411210000Z"
LAST-UPDATED "201601140000Z"
ORGANIZATION "NetPing East, Alentis Electronics"
CONTACT-INFO
"developers@netping.ru"
DESCRIPTION
"Generic MIB for NetPing remote sensing and control"
REVISION "201601140000Z"
DESCRIPTION
"npIrStatus values changed"
REVISION "201509240000Z"
DESCRIPTION
"npElecMeter branch added"
REVISION "201411210000Z"
REVISION "201504090000Z"
DESCRIPTION
"npRelHumTrap added; npIoTrapLevelLegend added"
REVISION "201411210000Z"
DESCRIPTION
"npRelayFlip variable max-access bugfix"
@ -518,11 +530,19 @@ npIoTrapMemo OBJECT-TYPE
DESCRIPTION "Trap data, IO line memo"
::= { npIoTraps 6 }
npIoTrapLevelLegend OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Legend for current logic level on the IO line"
::= { npIoTraps 7 }
npIoTrap NOTIFICATION-TYPE
OBJECTS {
npIoTrapLineN,
npIoTrapLevelIn,
npIoTrapMemo
npIoTrapMemo,
npIoTrapLevelLegend
}
STATUS current
DESCRIPTION
@ -741,8 +761,24 @@ npRelHumSensorValueT100 OBJECT-TYPE
STATUS current
DESCRIPTION "Sensor temperature, deg.C * 100 (fixed point two decimal places)
Used to get access to the fractional part of T value"
::= { npRelHumSensor 9 }
::= { npRelHumSensor 9 }
npRelHumTraps OBJECT IDENTIFIER::={npRelHumidity 9}
npRelHumTrapPrefix OBJECT IDENTIFIER::={npRelHumTraps 0}
npRelHumTrap NOTIFICATION-TYPE
OBJECTS {
npRelHumSensorStatusH,
npRelHumSensorValueH,
npRelHumSafeRangeHigh,
npRelHumSafeRangeLow
}
STATUS current
DESCRIPTION
"Status of Relative Humidity RH sensor has changed!"
::= { npRelHumTrapPrefix 1 }
npIr OBJECT IDENTIFIER::={lightcom 7900}
npIrCtrl OBJECT IDENTIFIER::={npIr 1}
@ -764,16 +800,83 @@ npIrReset OBJECT-TYPE
npIrStatus OBJECT-TYPE
SYNTAX INTEGER {
ok (0),
busyCaptureWaitingButton (1),
busyCaptureWaitingIr (2),
busyPlayback (3),
error (255)
commandCompleted (0),
protocolError (1),
commandAccepted (2),
errorUnknown (16),
errorBadNumber (17),
errorEmptyRecord (18),
errorFlashChip (19),
errorTimeout (20),
errorExtBusBusy (21)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "IR transiever status"
::= { npIrCtrl 3 }
npElecMeter OBJECT IDENTIFIER::={lightcom 9700}
npElecTable OBJECT-TYPE
SYNTAX SEQUENCE OF NpElecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Electricity Meter Table"
::= { npElecMeter 1 }
npElecEntry OBJECT-TYPE
SYNTAX NpElecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Electricity Meter Table Table Row"
INDEX { npElecIndex }
::= { npElecTable 1 }
NpElecEntry ::= SEQUENCE {
npElecIndex INTEGER,
npElecPulsesPerKwh INTEGER,
npElecPower Gauge32,
npElecEnergy Counter32,
npElecEnergy100 Counter32
}
npElecIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of elec.meter, associated with IO line"
::= { npElecEntry 1 }
npElecPulsesPerKwh OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Pulses on IO line input per 1 kWh of consumed energy"
::= { npElecEntry 2 }
npElecPower OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Power, Watts, based on pulse rate/interval, 5 minute average"
::= { npElecEntry 3 }
npElecEnergy OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Energy counter, kWh, based on pulse count"
::= { npElecEntry 4 }
npElecEnergy100 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Energy counter, kWh*100, based on pulse count"
::= { npElecEntry 5 }
npReboot OBJECT IDENTIFIER::={ lightcom 911 }