initial commit; version 22.5.12042
This commit is contained in:
387
mibs/snr/SNR-ERD-2
Normal file
387
mibs/snr/SNR-ERD-2
Normal file
@ -0,0 +1,387 @@
|
||||
SNR-ERD-2 DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
enterprises, IpAddress, Counter
|
||||
FROM RFC1155-SMI
|
||||
DisplayString
|
||||
FROM RFC1213-MIB
|
||||
NOTIFICATION-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
;
|
||||
|
||||
snr MODULE-IDENTITY
|
||||
LAST-UPDATED "201504291200Z"
|
||||
ORGANIZATION "NAG "
|
||||
CONTACT-INFO "erd@nag.ru"
|
||||
DESCRIPTION
|
||||
"The MIB module for SNR-ERD"
|
||||
REVISION "201504291200Z"
|
||||
DESCRIPTION
|
||||
"Initial revision."
|
||||
::= { enterprises 40418 }
|
||||
|
||||
|
||||
|
||||
snr-erd OBJECT IDENTIFIER ::= { snr 2 }
|
||||
snr-erd-2 OBJECT IDENTIFIER ::= { snr-erd 2 }
|
||||
ipAddressEntry OBJECT IDENTIFIER ::= { snr-erd-2 1 }
|
||||
resetsSet OBJECT IDENTIFIER ::= { snr-erd-2 2 }
|
||||
sensesSet1 OBJECT IDENTIFIER ::= { snr-erd-2 3 }
|
||||
sensesSet2 OBJECT IDENTIFIER ::= { snr-erd-2 4 }
|
||||
commS OBJECT IDENTIFIER ::= { snr-erd-2 5 }
|
||||
|
||||
erd2Traps OBJECT IDENTIFIER ::= { snr-erd-2 0 }
|
||||
|
||||
|
||||
-- Traps
|
||||
|
||||
temperatureSensorAlarM NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 0 }
|
||||
|
||||
temperatureSensorReleasE NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 1 }
|
||||
|
||||
signalContactDIAAlarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 2 }
|
||||
|
||||
signalContactDIAOk NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 3 }
|
||||
|
||||
voltageSignalAlarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 4 }
|
||||
|
||||
voltageSignalOk NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 5 }
|
||||
|
||||
anySensorSignal1contactDI1Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 6 }
|
||||
|
||||
anySensorSignal1contactDI1Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 7 }
|
||||
|
||||
anySensorSignal2contactDI2Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 8 }
|
||||
|
||||
anySensorSignal2contactDI2Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 9 }
|
||||
|
||||
anySensorSignal3contactDI3Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 10 }
|
||||
|
||||
anySensorSignal3contactDI3Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 11 }
|
||||
|
||||
voltageAlarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 12 }
|
||||
|
||||
voltageOk NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 13 }
|
||||
|
||||
remoteControlContactDO2ON NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 14 }
|
||||
|
||||
remoteControlContactDO2OFF NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 15 }
|
||||
|
||||
resetedSmartContactDO1 NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 16 }
|
||||
|
||||
--erd2TrapGroup NOTIFICATION-GROUP
|
||||
-- NOTIFICATIONS
|
||||
-- {
|
||||
-- temperatureSensorAlarM,
|
||||
-- temperatureSensorReleasE,
|
||||
-- signalContact3Alarm,
|
||||
-- signalContact3Ok,
|
||||
-- voltageSignalAlarm,
|
||||
-- voltageSignalOk,
|
||||
-- anySensorSignal1contact4Alarm,
|
||||
-- anySensorSignal1contact4Ok,
|
||||
-- anySensorSignal2contact7Alarm,
|
||||
-- anySensorSignal2contact7Ok,
|
||||
-- anySensorSignal3contact9Alarm,
|
||||
-- anySensorSignal3contact9Ok,
|
||||
-- voltageAlarm,
|
||||
-- voltageOk,
|
||||
-- remoteControlContact8ON,
|
||||
-- remoteControlContact8OFF,
|
||||
-- resetedSmartContact6
|
||||
-- }
|
||||
--
|
||||
-- STATUS current
|
||||
--
|
||||
-- DESCRIPTION
|
||||
--
|
||||
-- " "
|
||||
--
|
||||
--::= { snr-erd-2 99 }
|
||||
|
||||
|
||||
|
||||
-- ipAddressEntry
|
||||
|
||||
ipAddress OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "myIp"
|
||||
::= {ipAddressEntry 1}
|
||||
|
||||
ipGatewayAddress OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "DGIp"
|
||||
::= {ipAddressEntry 2}
|
||||
|
||||
ipMonitoringDevice OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "monitoredIP"
|
||||
::= {ipAddressEntry 3}
|
||||
|
||||
ipForTrap OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "ipForTrap"
|
||||
::= {ipAddressEntry 4}
|
||||
|
||||
|
||||
-- resetsSet
|
||||
|
||||
resetSmartContactDO1 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
reset (1),
|
||||
bypass (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { resetsSet 1}
|
||||
|
||||
numberOfResetPositives OBJECT-TYPE
|
||||
SYNTAX INTEGER {resetPositives (0)}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { resetsSet 2 }
|
||||
|
||||
|
||||
remoteControlContactDO2 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
termostatSetON (3),
|
||||
switch (4),
|
||||
manualSetON (2),
|
||||
manOFF (1),
|
||||
manON (0),
|
||||
autoOFF (6),
|
||||
autoON (5)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { resetsSet 3 }
|
||||
|
||||
|
||||
-- sensesSet1
|
||||
|
||||
monitorAlarmSignalContactDIA OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
doorIsClose (1),
|
||||
doorIsOpen (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 1}
|
||||
|
||||
numberOfAlarmPositives OBJECT-TYPE
|
||||
SYNTAX INTEGER {resetPositives (0)}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 2 }
|
||||
|
||||
monitorAnySensorSignal1contactDI1 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
sensorIs0 (1),
|
||||
sensorIs1 (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 3 }
|
||||
|
||||
monitorAnySensorSignal2contactDI2 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
sensorIs0 (1),
|
||||
sensorIs1 (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 4 }
|
||||
|
||||
monitorAnySensorSignal3contactDI3 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
sensorIs0 (1),
|
||||
sensorIs1 (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 5 }
|
||||
|
||||
monitorVoltageSignal OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
voltageIsYes (2),
|
||||
voltageIsNo (1),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 6 }
|
||||
|
||||
|
||||
-- sensesSet2
|
||||
|
||||
temperatureSensor OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet2 1 }
|
||||
|
||||
voltageSensorContactADCIN OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet2 2 }
|
||||
|
||||
sysVoltageAlarm OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet2 3 }
|
||||
|
||||
humiditySensor OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet2 4 }
|
||||
|
||||
-- commS
|
||||
|
||||
communityString OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 1}
|
||||
|
||||
trapMode OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
once (1),
|
||||
cyclically (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 2}
|
||||
|
||||
alarmSenseName OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 3}
|
||||
|
||||
userSense1Name OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 5}
|
||||
|
||||
userSense2Name OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 6}
|
||||
|
||||
userSense3Name OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 7}
|
||||
|
||||
message OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Text trap message"
|
||||
::= {commS 10}
|
||||
|
||||
END
|
||||
|
562
mibs/snr/SNR-ERD-3
Normal file
562
mibs/snr/SNR-ERD-3
Normal file
@ -0,0 +1,562 @@
|
||||
SNR-ERD-3 DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
enterprises, IpAddress, Counter
|
||||
FROM RFC1155-SMI
|
||||
DisplayString
|
||||
FROM RFC1213-MIB
|
||||
NOTIFICATION-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
;
|
||||
|
||||
snr MODULE-IDENTITY
|
||||
LAST-UPDATED "201504291200Z"
|
||||
ORGANIZATION "NAG "
|
||||
CONTACT-INFO "erd@nag.ru"
|
||||
DESCRIPTION
|
||||
"The MIB module for SNR-ERD"
|
||||
REVISION "201504291200Z"
|
||||
DESCRIPTION
|
||||
"Initial revision."
|
||||
::= { enterprises 40418 }
|
||||
|
||||
|
||||
snr-erd OBJECT IDENTIFIER ::= { snr 2 }
|
||||
snr-erd-3 OBJECT IDENTIFIER ::= { snr-erd 3}
|
||||
ipAddressEntry OBJECT IDENTIFIER ::= { snr-erd-3 1 }
|
||||
resetsSet OBJECT IDENTIFIER ::= { snr-erd-3 2 }
|
||||
sensesSet1 OBJECT IDENTIFIER ::= { snr-erd-3 3 }
|
||||
sensesSet2 OBJECT IDENTIFIER ::= { snr-erd-3 4 }
|
||||
commS OBJECT IDENTIFIER ::= { snr-erd-3 5 }
|
||||
|
||||
temperatureSensorsOut OBJECT IDENTIFIER ::= { sensesSet2 2 }
|
||||
|
||||
erd3Traps OBJECT IDENTIFIER ::= { snr-erd-3 0 }
|
||||
|
||||
-- Traps
|
||||
|
||||
temperatureSensorAlarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 0 }
|
||||
|
||||
temperatureSensorRelease NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 1 }
|
||||
|
||||
signal1Contact5Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 2 }
|
||||
|
||||
signal1Contact5Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 3 }
|
||||
|
||||
signal2Contact6Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 4 }
|
||||
|
||||
signal2Contact6Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 5 }
|
||||
|
||||
voltageSignal1Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 6 }
|
||||
|
||||
voltageSignal1Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 7 }
|
||||
|
||||
voltageSignal2Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 8 }
|
||||
|
||||
voltageSignal2Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 9 }
|
||||
|
||||
anySensorSignal1contact2Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 10 }
|
||||
|
||||
anySensorSignal1contact2Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 11 }
|
||||
|
||||
anySensorSignal2contact3Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 12 }
|
||||
|
||||
anySensorSignal2contact3Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 13 }
|
||||
|
||||
anySensorSignal3contact4Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 14 }
|
||||
|
||||
anySensorSignal3contact4Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 15 }
|
||||
|
||||
voltage1Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 16 }
|
||||
|
||||
voltage1Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 17 }
|
||||
|
||||
voltage2Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 18 }
|
||||
|
||||
voltage2Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 19 }
|
||||
|
||||
remoteControlContact8On NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 20 }
|
||||
|
||||
remoteControlContact8Off NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 21 }
|
||||
|
||||
resetedSmartContact7 NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 22 }
|
||||
|
||||
temperatureSensorOutAlarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 23 }
|
||||
|
||||
temperatureSensorOutRelease NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 24 }
|
||||
|
||||
temperatureSensorOutFail NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 25 }
|
||||
|
||||
temperatureSensorOutOk NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3Traps 26 }
|
||||
|
||||
erd3TrapGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS
|
||||
{
|
||||
temperatureSensorAlarm,
|
||||
temperatureSensorRelease,
|
||||
signal1Contact5Alarm,
|
||||
|
||||
signal1Contact5Ok,
|
||||
signal2Contact6Alarm,
|
||||
|
||||
signal2Contact6Ok,
|
||||
voltageSignal1Alarm,
|
||||
voltageSignal1Ok,
|
||||
voltageSignal2Alarm,
|
||||
voltageSignal2Ok,
|
||||
anySensorSignal1contact2Alarm,
|
||||
anySensorSignal1contact2Ok,
|
||||
anySensorSignal2contact3Alarm,
|
||||
anySensorSignal2contact3Ok,
|
||||
anySensorSignal3contact4Alarm,
|
||||
anySensorSignal3contact4Ok,
|
||||
voltage1Alarm,
|
||||
voltage1Ok,
|
||||
voltage2Alarm,
|
||||
voltage2Ok,
|
||||
remoteControlContact8On,
|
||||
remoteControlContact8Off,
|
||||
resetedSmartContact7,
|
||||
temperatureSensorOutAlarm,
|
||||
temperatureSensorOutRelease,
|
||||
temperatureSensorOutFail,
|
||||
temperatureSensorOutOk
|
||||
}
|
||||
|
||||
STATUS current
|
||||
|
||||
DESCRIPTION
|
||||
|
||||
" "
|
||||
|
||||
::= { snr-erd-3 99 }
|
||||
|
||||
|
||||
-- ipAddressEntry
|
||||
|
||||
ipAddress OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "myIp"
|
||||
::= {ipAddressEntry 1}
|
||||
|
||||
ipGatewayAddress OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "DGIp"
|
||||
::= {ipAddressEntry 2}
|
||||
|
||||
ipMonitoringDevice OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "monitoredIP"
|
||||
::= {ipAddressEntry 3}
|
||||
|
||||
ipForTrap OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "ipForTrap"
|
||||
::= {ipAddressEntry 4}
|
||||
|
||||
|
||||
-- resetsSet
|
||||
|
||||
resetSmartContact7 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
reset (1),
|
||||
bypass (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { resetsSet 1}
|
||||
|
||||
numberOfResetPositives OBJECT-TYPE
|
||||
SYNTAX INTEGER {resetPositives (0)}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { resetsSet 2 }
|
||||
|
||||
|
||||
remoteControlContact8 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
termostatSetON (3),
|
||||
switch (4),
|
||||
manualSetON (2),
|
||||
manOFF (1),
|
||||
manON (0),
|
||||
autoOFF (6),
|
||||
autoON (5)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { resetsSet 3 }
|
||||
|
||||
|
||||
-- sensesSet1
|
||||
|
||||
monitorAlarmSignal1Contact5 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
doorIsClose (1),
|
||||
doorIsOpen (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 1}
|
||||
|
||||
monitorAlarmSignal2Contact6 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
doorIsClose (1),
|
||||
doorIsOpen (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 2 }
|
||||
|
||||
numberOfAlarmPositives OBJECT-TYPE
|
||||
SYNTAX INTEGER {resetPositives (0)}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 3 }
|
||||
|
||||
monitorAnySensorSignal1contact2 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
sensorIs0 (1),
|
||||
sensorIs1 (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 4 }
|
||||
|
||||
monitorAnySensorSignal2contact3 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
sensorIs0 (1),
|
||||
sensorIs1 (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 5 }
|
||||
|
||||
monitorAnySensorSignal3contact4 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
sensorIs0 (1),
|
||||
sensorIs1 (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 6 }
|
||||
|
||||
monitorVoltageSignal1 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
voltageIsYes (2),
|
||||
voltageIsNo (1),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 7 }
|
||||
|
||||
monitorVoltageSignal2 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn(3),
|
||||
voltageIsYes (2),
|
||||
voltageIsNo (1),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 8 }
|
||||
|
||||
|
||||
-- sensesSet2
|
||||
|
||||
temperatureSensor OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet2 1 }
|
||||
|
||||
|
||||
temperatureSensorOutSerial1 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 1 }
|
||||
|
||||
temperatureSensorOut1 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 2 }
|
||||
|
||||
temperatureSensorOutSerial2 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 3 }
|
||||
|
||||
temperatureSensorOut2 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 4 }
|
||||
|
||||
temperatureSensorOutSerial3 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 5 }
|
||||
|
||||
temperatureSensorOut3 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 6 }
|
||||
|
||||
temperatureSensorOutSerial4 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 7 }
|
||||
|
||||
temperatureSensorOut4 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 8 }
|
||||
|
||||
temperatureSensorOutSerial5 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 9 }
|
||||
|
||||
temperatureSensorOut5 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 10 }
|
||||
|
||||
voltageSensor1Contact10 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet2 3 }
|
||||
|
||||
sysVoltageAlarm OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet2 4 }
|
||||
|
||||
voltageSensor2Contact11 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet2 5 }
|
||||
|
||||
sysVoltage2Alarm OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet2 6 }
|
||||
|
||||
|
||||
-- commS
|
||||
|
||||
communityString OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 1}
|
||||
|
||||
trapMode OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
once (1),
|
||||
cyclically (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 2}
|
||||
|
||||
alarmSense1Name OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 3}
|
||||
|
||||
alarmSense2Name OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 4}
|
||||
|
||||
userSense1Name OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 5}
|
||||
|
||||
userSense2Name OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 6}
|
||||
|
||||
userSense3Name OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 7}
|
||||
|
||||
|
||||
message OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Text trap message"
|
||||
::= {commS 10}
|
||||
|
||||
|
||||
END
|
||||
|
633
mibs/snr/SNR-ERD-3s
Normal file
633
mibs/snr/SNR-ERD-3s
Normal file
@ -0,0 +1,633 @@
|
||||
SNR-ERD-3s DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
enterprises, IpAddress, Counter, Opaque
|
||||
FROM RFC1155-SMI
|
||||
DisplayString
|
||||
FROM RFC1213-MIB
|
||||
NOTIFICATION-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
TEXTUAL-CONVENTION
|
||||
FROM SNMPv2-TC
|
||||
;
|
||||
|
||||
snr MODULE-IDENTITY
|
||||
LAST-UPDATED "201504291200Z"
|
||||
ORGANIZATION "NAG "
|
||||
CONTACT-INFO "erd@nag.ru"
|
||||
DESCRIPTION
|
||||
"The MIB module for SNR-ERD"
|
||||
REVISION "201504291200Z"
|
||||
DESCRIPTION
|
||||
"Initial revision."
|
||||
::= { enterprises 40418 }
|
||||
|
||||
|
||||
snr-erd OBJECT IDENTIFIER ::= { snr 2 }
|
||||
snr-erd-3s OBJECT IDENTIFIER ::= { snr-erd 4}
|
||||
ipAddressEntry OBJECT IDENTIFIER ::= { snr-erd-3s 1 }
|
||||
resetsSet OBJECT IDENTIFIER ::= { snr-erd-3s 2 }
|
||||
sensesSet1 OBJECT IDENTIFIER ::= { snr-erd-3s 3 }
|
||||
sensesSet2 OBJECT IDENTIFIER ::= { snr-erd-3s 4 }
|
||||
commS OBJECT IDENTIFIER ::= { snr-erd-3s 5 }
|
||||
upsMonitoring OBJECT IDENTIFIER ::= { snr-erd-3s 6 }
|
||||
|
||||
temperatureSensorsOut OBJECT IDENTIFIER ::= { sensesSet2 2 }
|
||||
|
||||
erd3sTraps OBJECT IDENTIFIER ::= { snr-erd-3s 0 }
|
||||
|
||||
Float ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A single precision floating-point number. The semantics
|
||||
and encoding are identical for type 'single' defined in
|
||||
IEEE Standard for Binary Floating-Point,
|
||||
ANSI/IEEE Std 754-1985.
|
||||
The value is restricted to the BER serialization of
|
||||
the following ASN.1 type:
|
||||
FLOATTYPE ::= [120] IMPLICIT FloatType
|
||||
(note: the value 120 is the sum of '30'h and '48'h)
|
||||
The BER serialization of the length for values of
|
||||
this type must use the definite length, short
|
||||
encoding form.
|
||||
|
||||
For example, the BER serialization of value 123
|
||||
of type FLOATTYPE is '9f780442f60000'h. (The tag
|
||||
is '9f78'h; the length is '04'h; and the value is
|
||||
'42f60000'h.) The BER serialization of value
|
||||
'9f780442f60000'h of data type Opaque is
|
||||
'44079f780442f60000'h. (The tag is '44'h; the length
|
||||
is '07'h; and the value is '9f780442f60000'h."
|
||||
SYNTAX Opaque (SIZE(7))
|
||||
|
||||
|
||||
|
||||
-- Traps
|
||||
|
||||
temperatureSensorAlarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 0 }
|
||||
|
||||
temperatureSensorRelease NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 1 }
|
||||
|
||||
signal1Contact8Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 2 }
|
||||
|
||||
signal1Contact8Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 3 }
|
||||
|
||||
signal2Contact9Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 4 }
|
||||
|
||||
signal2Contact9Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 5 }
|
||||
|
||||
voltageSignal1Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 6 }
|
||||
|
||||
voltageSignal1Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 7 }
|
||||
|
||||
voltageSignal2Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 8 }
|
||||
|
||||
voltageSignal2Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 9 }
|
||||
|
||||
anySensorSignal1contact5Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 10 }
|
||||
|
||||
anySensorSignal1contact5Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 11 }
|
||||
|
||||
anySensorSignal2contact6Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 12 }
|
||||
|
||||
anySensorSignal2contact6Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 13 }
|
||||
|
||||
anySensorSignal3contact7Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 14 }
|
||||
|
||||
anySensorSignal3contact7Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 15 }
|
||||
|
||||
voltageAlarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 16 }
|
||||
|
||||
voltageOk NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 17 }
|
||||
|
||||
remoteControlContact11On NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 18 }
|
||||
|
||||
remoteControlContact11Off NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 19 }
|
||||
|
||||
resetedSmartContact10 NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 20 }
|
||||
|
||||
temperatureSensorOutAlarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 23 }
|
||||
|
||||
temperatureSensorOutRelease NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 24 }
|
||||
|
||||
temperatureSensorOutFail NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 25 }
|
||||
|
||||
temperatureSensorOutOk NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 26 }
|
||||
|
||||
upsUtilityFail NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 30 }
|
||||
|
||||
upsUtilityOk NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd3sTraps 31 }
|
||||
|
||||
erd3sTrapGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS
|
||||
{
|
||||
temperatureSensorAlarm,
|
||||
temperatureSensorRelease,
|
||||
signal1Contact8Alarm,
|
||||
|
||||
signal1Contact8Ok,
|
||||
signal2Contact9Alarm,
|
||||
|
||||
signal2Contact9Ok,
|
||||
voltageSignal1Alarm,
|
||||
voltageSignal1Ok,
|
||||
voltageSignal2Alarm,
|
||||
voltageSignal2Ok,
|
||||
anySensorSignal1contact5Alarm,
|
||||
anySensorSignal1contact5Ok,
|
||||
anySensorSignal2contact6Alarm,
|
||||
anySensorSignal2contact6Ok,
|
||||
anySensorSignal3contact7Alarm,
|
||||
anySensorSignal3contact7Ok,
|
||||
voltageAlarm,
|
||||
voltageOk,
|
||||
remoteControlContact11On,
|
||||
remoteControlContact11Off,
|
||||
resetedSmartContact10,
|
||||
temperatureSensorOutAlarm,
|
||||
temperatureSensorOutRelease,
|
||||
temperatureSensorOutFail,
|
||||
temperatureSensorOutOk,
|
||||
upsUtilityFail,
|
||||
upsUtilityOk
|
||||
}
|
||||
|
||||
STATUS current
|
||||
|
||||
DESCRIPTION
|
||||
|
||||
" "
|
||||
|
||||
::= { snr-erd-3s 99 }
|
||||
|
||||
|
||||
-- ipAddressEntry
|
||||
|
||||
ipAddress OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "myIp"
|
||||
::= {ipAddressEntry 1}
|
||||
|
||||
ipGatewayAddress OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "DGIp"
|
||||
::= {ipAddressEntry 2}
|
||||
|
||||
ipMonitoringDevice OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "monitoredIP"
|
||||
::= {ipAddressEntry 3}
|
||||
|
||||
ipForTrap OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "ipForTrap"
|
||||
::= {ipAddressEntry 4}
|
||||
|
||||
|
||||
-- resetsSet
|
||||
|
||||
resetSmartContact10 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
reset (1),
|
||||
bypass (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { resetsSet 1}
|
||||
|
||||
numberOfResetPositives OBJECT-TYPE
|
||||
SYNTAX INTEGER {resetPositives (0)}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { resetsSet 2 }
|
||||
|
||||
|
||||
remoteControlContact11 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
termostatSetON (3),
|
||||
switch (4),
|
||||
manualSetON (2),
|
||||
manOFF (1),
|
||||
manON (0),
|
||||
autoOFF (6),
|
||||
autoON (5)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { resetsSet 3 }
|
||||
|
||||
|
||||
-- sensesSet1
|
||||
|
||||
monitorAlarmSignal1Contact8 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
doorIsClose (1),
|
||||
doorIsOpen (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 1}
|
||||
|
||||
monitorAlarmSignal2Contact9 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
doorIsClose (1),
|
||||
doorIsOpen (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 2 }
|
||||
|
||||
numberOfAlarmPositives OBJECT-TYPE
|
||||
SYNTAX INTEGER {resetPositives (0)}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 3 }
|
||||
|
||||
monitorAnySensorSignal1contact5 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
sensorIs0 (1),
|
||||
sensorIs1 (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 4 }
|
||||
|
||||
monitorAnySensorSignal2contact6 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
sensorIs0 (1),
|
||||
sensorIs1 (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 5 }
|
||||
|
||||
monitorAnySensorSignal3contact7 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
sensorIs0 (1),
|
||||
sensorIs1 (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 6 }
|
||||
|
||||
monitorVoltageSignal1 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
voltageIsYes (2),
|
||||
voltageIsNo (1),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 7 }
|
||||
|
||||
monitorVoltageSignal2 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn(3),
|
||||
voltageIsYes (2),
|
||||
voltageIsNo (1),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 8 }
|
||||
|
||||
|
||||
-- sensesSet2
|
||||
|
||||
temperatureSensor OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet2 1 }
|
||||
|
||||
|
||||
temperatureSensorOutSerial1 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 1 }
|
||||
|
||||
temperatureSensorOut1 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 2 }
|
||||
|
||||
temperatureSensorOutSerial2 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 3 }
|
||||
|
||||
temperatureSensorOut2 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 4 }
|
||||
|
||||
temperatureSensorOutSerial3 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 5 }
|
||||
|
||||
temperatureSensorOut3 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 6 }
|
||||
|
||||
temperatureSensorOutSerial4 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 7 }
|
||||
|
||||
temperatureSensorOut4 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 8 }
|
||||
|
||||
temperatureSensorOutSerial5 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 9 }
|
||||
|
||||
temperatureSensorOut5 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensorsOut 10 }
|
||||
|
||||
voltageSensorContact12 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet2 3 }
|
||||
|
||||
sysVoltageAlarm OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet2 4 }
|
||||
|
||||
|
||||
-- commS
|
||||
|
||||
communityString OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 1}
|
||||
|
||||
trapMode OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
once (1),
|
||||
cyclically (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 2}
|
||||
|
||||
alarmSense1Name OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 3}
|
||||
|
||||
alarmSense2Name OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 4}
|
||||
|
||||
userSense1Name OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 5}
|
||||
|
||||
userSense2Name OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 6}
|
||||
|
||||
userSense3Name OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 7}
|
||||
|
||||
|
||||
dataType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
integer (0),
|
||||
float (1),
|
||||
uni (2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 10}
|
||||
|
||||
|
||||
|
||||
-- upsMonitoring
|
||||
|
||||
batteryVoltage OBJECT-TYPE
|
||||
SYNTAX Float
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { upsMonitoring 1 }
|
||||
|
||||
upsTemperature OBJECT-TYPE
|
||||
SYNTAX Float
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { upsMonitoring 2 }
|
||||
|
||||
inputVoltage OBJECT-TYPE
|
||||
SYNTAX Float
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { upsMonitoring 3 }
|
||||
|
||||
outputVoltage OBJECT-TYPE
|
||||
SYNTAX Float
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { upsMonitoring 4 }
|
||||
|
||||
upsLoading OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { upsMonitoring 5 }
|
||||
|
||||
upsStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
unknown (2),
|
||||
utilityFail (1),
|
||||
utilityOk (0)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { upsMonitoring 6 }
|
||||
|
||||
|
||||
END
|
||||
|
1275
mibs/snr/SNR-ERD-4
Normal file
1275
mibs/snr/SNR-ERD-4
Normal file
File diff suppressed because it is too large
Load Diff
381
mibs/snr/SNR-ERD-DUST
Normal file
381
mibs/snr/SNR-ERD-DUST
Normal file
@ -0,0 +1,381 @@
|
||||
SNR-ERD-DUST DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
enterprises, IpAddress, Counter
|
||||
FROM RFC1155-SMI
|
||||
DisplayString
|
||||
FROM RFC1213-MIB
|
||||
NOTIFICATION-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
;
|
||||
|
||||
snr MODULE-IDENTITY
|
||||
LAST-UPDATED "201504291200Z"
|
||||
ORGANIZATION "NAG "
|
||||
CONTACT-INFO "erd@nag.ru"
|
||||
DESCRIPTION
|
||||
"The MIB module for SNR-ERD"
|
||||
REVISION "201504291200Z"
|
||||
DESCRIPTION
|
||||
"Initial revision."
|
||||
::= { enterprises 40418 }
|
||||
|
||||
|
||||
|
||||
snr-erd OBJECT IDENTIFIER ::= { snr 2 }
|
||||
snr-erd-2 OBJECT IDENTIFIER ::= { snr-erd 2 }
|
||||
ipAddressEntry OBJECT IDENTIFIER ::= { snr-erd-2 1 }
|
||||
resetsSet OBJECT IDENTIFIER ::= { snr-erd-2 2 }
|
||||
sensesSet1 OBJECT IDENTIFIER ::= { snr-erd-2 3 }
|
||||
sensesSet2 OBJECT IDENTIFIER ::= { snr-erd-2 4 }
|
||||
commS OBJECT IDENTIFIER ::= { snr-erd-2 5 }
|
||||
|
||||
erd2Traps OBJECT IDENTIFIER ::= { snr-erd-2 0 }
|
||||
|
||||
|
||||
-- Traps
|
||||
|
||||
temperatureSensorAlarM NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 0 }
|
||||
|
||||
temperatureSensorReleasE NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 1 }
|
||||
|
||||
signalContact3Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 2 }
|
||||
|
||||
signalContact3Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 3 }
|
||||
|
||||
voltageSignalAlarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 4 }
|
||||
|
||||
voltageSignalOk NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 5 }
|
||||
|
||||
anySensorSignal1contact4Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 6 }
|
||||
|
||||
anySensorSignal1contact4Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 7 }
|
||||
|
||||
anySensorSignal2contact7Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 8 }
|
||||
|
||||
anySensorSignal2contact7Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 9 }
|
||||
|
||||
anySensorSignal3contact9Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 10 }
|
||||
|
||||
anySensorSignal3contact9Ok NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 11 }
|
||||
|
||||
voltageAlarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 12 }
|
||||
|
||||
voltageOk NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 13 }
|
||||
|
||||
remoteControlContact8ON NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 14 }
|
||||
|
||||
remoteControlContact8OFF NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 15 }
|
||||
|
||||
resetedSmartContact6 NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erd2Traps 16 }
|
||||
|
||||
erd2TrapGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS
|
||||
{
|
||||
temperatureSensorAlarM,
|
||||
temperatureSensorReleasE,
|
||||
signalContact3Alarm,
|
||||
signalContact3Ok,
|
||||
voltageSignalAlarm,
|
||||
voltageSignalOk,
|
||||
anySensorSignal1contact4Alarm,
|
||||
anySensorSignal1contact4Ok,
|
||||
anySensorSignal2contact7Alarm,
|
||||
anySensorSignal2contact7Ok,
|
||||
anySensorSignal3contact9Alarm,
|
||||
anySensorSignal3contact9Ok,
|
||||
voltageAlarm,
|
||||
voltageOk,
|
||||
remoteControlContact8ON,
|
||||
remoteControlContact8OFF,
|
||||
resetedSmartContact6
|
||||
}
|
||||
|
||||
STATUS current
|
||||
|
||||
DESCRIPTION
|
||||
|
||||
" "
|
||||
|
||||
::= { snr-erd-2 99 }
|
||||
|
||||
|
||||
|
||||
-- ipAddressEntry
|
||||
|
||||
ipAddress OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "myIp"
|
||||
::= {ipAddressEntry 1}
|
||||
|
||||
ipGatewayAddress OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "DGIp"
|
||||
::= {ipAddressEntry 2}
|
||||
|
||||
ipMonitoringDevice OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "monitoredIP"
|
||||
::= {ipAddressEntry 3}
|
||||
|
||||
ipForTrap OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "ipForTrap"
|
||||
::= {ipAddressEntry 4}
|
||||
|
||||
|
||||
-- resetsSet
|
||||
|
||||
resetSmartContact6 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
reset (1),
|
||||
bypass (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { resetsSet 1}
|
||||
|
||||
numberOfResetDevice OBJECT-TYPE
|
||||
SYNTAX INTEGER {resetPositives (0)}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { resetsSet 2 }
|
||||
|
||||
|
||||
remoteControlContact8 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
termostatSetON (3),
|
||||
switch (4),
|
||||
manualSetON (2),
|
||||
manOFF (1),
|
||||
manON (0),
|
||||
autoOFF (6),
|
||||
autoON (5)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { resetsSet 3 }
|
||||
|
||||
|
||||
-- sensesSet1
|
||||
|
||||
monitorAlarmSignalContact3 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
doorIsClose (1),
|
||||
doorIsOpen (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 1}
|
||||
|
||||
numberOfAlarms OBJECT-TYPE
|
||||
SYNTAX INTEGER {resetPositives (0)}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 2 }
|
||||
|
||||
monitorAnySensorSignal1contact4 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
sensorIs0 (1),
|
||||
sensorIs1 (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 3 }
|
||||
|
||||
monitorAnySensorSignal2contact7 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
sensorIs0 (1),
|
||||
sensorIs1 (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 4 }
|
||||
|
||||
monitorAnySensorSignal3contact9 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
sensorIs0 (1),
|
||||
sensorIs1 (2),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 5 }
|
||||
|
||||
monitorVoltageSignal OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
sensorOn (3),
|
||||
voltageIsYes (2),
|
||||
voltageIsNo (1),
|
||||
sensorOff (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet1 6 }
|
||||
|
||||
|
||||
-- sensesSet2
|
||||
|
||||
temperatureSensor OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet2 1 }
|
||||
|
||||
dustSensor OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet2 2 }
|
||||
|
||||
dustCritical OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesSet2 3 }
|
||||
|
||||
|
||||
-- commS
|
||||
|
||||
communityString OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 1}
|
||||
|
||||
trapMode OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
once (1),
|
||||
cyclically (0)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 2}
|
||||
|
||||
alarmSenseName OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 3}
|
||||
|
||||
userSense1Name OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 5}
|
||||
|
||||
userSense2Name OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 6}
|
||||
|
||||
userSense3Name OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= {commS 7}
|
||||
|
||||
message OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Text trap message"
|
||||
::= {commS 10}
|
||||
|
||||
END
|
||||
|
590
mibs/snr/SNR-ERD-PRO-Mini
Normal file
590
mibs/snr/SNR-ERD-PRO-Mini
Normal file
@ -0,0 +1,590 @@
|
||||
SNR-ERD-PRO-Mini DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
enterprises, IpAddress, Counter
|
||||
FROM RFC1155-SMI
|
||||
DisplayString
|
||||
FROM RFC1213-MIB
|
||||
NOTIFICATION-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
;
|
||||
|
||||
snr MODULE-IDENTITY
|
||||
LAST-UPDATED "201504291200Z"
|
||||
ORGANIZATION "NAG "
|
||||
CONTACT-INFO "erd@nag.ru"
|
||||
DESCRIPTION
|
||||
"The MIB module for SNR-ERD"
|
||||
REVISION "201504291200Z"
|
||||
DESCRIPTION
|
||||
"Initial revision."
|
||||
::= { enterprises 40418 }
|
||||
|
||||
|
||||
snr-erd OBJECT IDENTIFIER ::= { snr 2 }
|
||||
snr-erd-pro-mini OBJECT IDENTIFIER ::= { snr-erd 5 }
|
||||
|
||||
measurements OBJECT IDENTIFIER ::= { snr-erd-pro-mini 1 }
|
||||
sensesstate OBJECT IDENTIFIER ::= { snr-erd-pro-mini 2 }
|
||||
management OBJECT IDENTIFIER ::= { snr-erd-pro-mini 3 }
|
||||
counters OBJECT IDENTIFIER ::= { snr-erd-pro-mini 8 }
|
||||
options OBJECT IDENTIFIER ::= { snr-erd-pro-mini 10 }
|
||||
|
||||
snrSensors OBJECT IDENTIFIER ::= { measurements 1 }
|
||||
temperatureSensors OBJECT IDENTIFIER ::= { snrSensors 1 }
|
||||
powerSensors OBJECT IDENTIFIER ::= { snrSensors 2 }
|
||||
alarmSensCnts OBJECT IDENTIFIER ::= { counters 2 }
|
||||
|
||||
erdproMiniTraps OBJECT IDENTIFIER ::= { snr-erd-pro-mini 0 }
|
||||
|
||||
|
||||
-- measurements
|
||||
|
||||
voltageSensor OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { measurements 2 }
|
||||
|
||||
|
||||
-- snrSensors
|
||||
|
||||
serialS1 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { snrSensors 10 }
|
||||
|
||||
serialS2 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { snrSensors 11 }
|
||||
|
||||
serialS3 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { snrSensors 12 }
|
||||
|
||||
serialS4 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { snrSensors 13 }
|
||||
|
||||
serialS5 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { snrSensors 14 }
|
||||
|
||||
serialS6 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { snrSensors 15 }
|
||||
|
||||
serialS7 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { snrSensors 16 }
|
||||
|
||||
serialS8 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { snrSensors 17 }
|
||||
|
||||
serialS9 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { snrSensors 18 }
|
||||
|
||||
serialS10 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { snrSensors 19 }
|
||||
|
||||
|
||||
|
||||
-- temperatureSensors
|
||||
|
||||
temperatureS1 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensors 1 }
|
||||
|
||||
temperatureS2 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensors 2 }
|
||||
|
||||
temperatureS3 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensors 3 }
|
||||
|
||||
temperatureS4 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensors 4 }
|
||||
|
||||
temperatureS5 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensors 5 }
|
||||
|
||||
temperatureS6 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensors 6 }
|
||||
|
||||
temperatureS7 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensors 7 }
|
||||
|
||||
temperatureS8 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensors 8 }
|
||||
|
||||
temperatureS9 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensors 9 }
|
||||
|
||||
temperatureS10 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { temperatureSensors 10 }
|
||||
|
||||
|
||||
-- powerSensors
|
||||
|
||||
voltageS1 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 1 }
|
||||
|
||||
currentS1 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 2 }
|
||||
|
||||
voltageS2 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 4 }
|
||||
|
||||
currentS2 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 5 }
|
||||
|
||||
voltageS3 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 7 }
|
||||
|
||||
currentS3 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 8 }
|
||||
|
||||
voltageS4 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 10 }
|
||||
|
||||
currentS4 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 11 }
|
||||
|
||||
voltageS5 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 13 }
|
||||
|
||||
currentS5 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 14 }
|
||||
|
||||
voltageS6 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 16 }
|
||||
|
||||
currentS6 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 17 }
|
||||
|
||||
voltageS7 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 19 }
|
||||
|
||||
currentS7 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 20 }
|
||||
|
||||
voltageS8 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 22 }
|
||||
|
||||
currentS8 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 23 }
|
||||
|
||||
voltageS9 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 25 }
|
||||
|
||||
currentS9 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 26 }
|
||||
|
||||
voltageS10 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 28 }
|
||||
|
||||
currentS10 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { powerSensors 29 }
|
||||
|
||||
|
||||
-- sensesstate
|
||||
|
||||
alarmSensor1 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
high (1),
|
||||
low (0)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesstate 1 }
|
||||
|
||||
alarmSensor2 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
high (1),
|
||||
low (0)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesstate 2 }
|
||||
|
||||
uSensor OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
no (1),
|
||||
yes (0)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { sensesstate 5 }
|
||||
|
||||
|
||||
-- management
|
||||
|
||||
smart1State OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
on (1),
|
||||
off (0),
|
||||
reset (2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { management 1 }
|
||||
|
||||
smart2State OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
on (1),
|
||||
off (0),
|
||||
reset (2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { management 2 }
|
||||
|
||||
smart1ResetTime OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { management 5 }
|
||||
|
||||
smart2ResetTime OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { management 6 }
|
||||
|
||||
|
||||
-- counters
|
||||
|
||||
alarmSensor1cnt OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { alarmSensCnts 1 }
|
||||
|
||||
alarmSensor2cnt OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { alarmSensCnts 2 }
|
||||
|
||||
|
||||
|
||||
-- options
|
||||
|
||||
dataType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
integer (0),
|
||||
float (1),
|
||||
ufloat (2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "qwerty"
|
||||
::= { options 1 }
|
||||
|
||||
|
||||
-- Traps
|
||||
|
||||
aSense1Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 1 }
|
||||
|
||||
aSense1Release NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 2 }
|
||||
|
||||
aSense2Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 3 }
|
||||
|
||||
aSense2Release NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 4 }
|
||||
|
||||
uSenseAlarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 9 }
|
||||
|
||||
uSenseRelease NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 10 }
|
||||
|
||||
smart1ThermoOn NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 13 }
|
||||
|
||||
smart1ThermoOff NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 14 }
|
||||
|
||||
smart2ThermoOn NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 15 }
|
||||
|
||||
smart2ThermoOff NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 16 }
|
||||
|
||||
tempSensorAlarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 29 }
|
||||
|
||||
tempSensorRelease NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 30 }
|
||||
|
||||
voltSensorAlarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 31 }
|
||||
|
||||
voltSensorRelease NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 32 }
|
||||
|
||||
task1Done NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 36 }
|
||||
|
||||
task2Done NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 37 }
|
||||
|
||||
task3Done NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 38 }
|
||||
|
||||
task4Done NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 39 }
|
||||
|
||||
pingLost NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 45 }
|
||||
|
||||
batteryChargeLow NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Check the text of message"
|
||||
::= { erdproMiniTraps 47 }
|
||||
|
||||
|
||||
erdProMiniTrapGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS
|
||||
{
|
||||
aSense1Alarm,
|
||||
aSense1Release,
|
||||
aSense2Alarm,
|
||||
aSense2Release,
|
||||
uSenseAlarm,
|
||||
uSenseRelease,
|
||||
smart1ThermoOn,
|
||||
smart1ThermoOff,
|
||||
smart2ThermoOn,
|
||||
smart2ThermoOff,
|
||||
tempSensorAlarm,
|
||||
tempSensorRelease,
|
||||
voltSensorAlarm,
|
||||
voltSensorRelease,
|
||||
task1Done,
|
||||
task2Done,
|
||||
task3Done,
|
||||
task4Done,
|
||||
pingLost,
|
||||
batteryChargeLow
|
||||
}
|
||||
|
||||
STATUS current
|
||||
|
||||
DESCRIPTION
|
||||
|
||||
" "
|
||||
|
||||
::= { snr-erd-pro-mini 99 }
|
||||
|
||||
END
|
||||
|
934
mibs/snr/SNR-ERD-Project
Normal file
934
mibs/snr/SNR-ERD-Project
Normal file
@ -0,0 +1,934 @@
|
||||
SNR-ERD-Project DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
enterprises, IpAddress, Counter
|
||||
FROM RFC1155-SMI
|
||||
DisplayString
|
||||
FROM RFC1213-MIB
|
||||
NOTIFICATION-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
;
|
||||
|
||||
snr MODULE-IDENTITY
|
||||
LAST-UPDATED "201504291200Z"
|
||||
ORGANIZATION "NAG "
|
||||
CONTACT-INFO "erd@nag.ru"
|
||||
DESCRIPTION
|
||||
"The MIB module for SNR-ERD"
|
||||
REVISION "201504291200Z"
|
||||
DESCRIPTION
|
||||
"Initial revision."
|
||||
::= { enterprises 40418 }
|
||||
|
||||
|
||||
snr-erd OBJECT IDENTIFIER ::= { snr 2 }
|
||||
snr-erd-project OBJECT IDENTIFIER ::= { snr-erd 7 }
|
||||
|
||||
measurements OBJECT IDENTIFIER ::= { snr-erd-project 1 }
|
||||
|
||||
dio OBJECT IDENTIFIER ::= { snr-erd-project 2 }
|
||||
options OBJECT IDENTIFIER ::= { snr-erd-project 10 }
|
||||
diffparams OBJECT IDENTIFIER ::= { snr-erd-project 11 }
|
||||
|
||||
|
||||
oneWire OBJECT IDENTIFIER ::= { measurements 1 }
|
||||
sp OBJECT IDENTIFIER ::= { measurements 30 }
|
||||
|
||||
upsStatus OBJECT IDENTIFIER ::= { diffparams 1 }
|
||||
|
||||
-- pid OBJECT IDENTIFIER ::= { diffparams 10 }
|
||||
|
||||
traps OBJECT IDENTIFIER ::= { snr-erd-project 0 }
|
||||
|
||||
crit OBJECT IDENTIFIER ::= { options 10 }
|
||||
|
||||
-- measurements
|
||||
|
||||
adc1Sensor OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "ADC1 sensor value"
|
||||
::= { measurements 2 }
|
||||
|
||||
adc2Sensor OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "ADC2 sensor value"
|
||||
::= { measurements 3 }
|
||||
|
||||
uSenseSensor OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "USense sensor value"
|
||||
::= { measurements 4 }
|
||||
|
||||
temperatureDHT OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "DHT temperature value"
|
||||
::= { measurements 8 }
|
||||
|
||||
humidityDHT OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "DHT humidity value"
|
||||
::= { measurements 9 }
|
||||
|
||||
-- dtsTable
|
||||
|
||||
dtsTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF dtsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "A list of temperature sensors values"
|
||||
::= { oneWire 1 }
|
||||
|
||||
dtsEntry OBJECT-TYPE
|
||||
SYNTAX dtsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "An entry (conceptual row) in the dtsTable"
|
||||
INDEX { dtsId }
|
||||
::= { dtsTable 1 }
|
||||
|
||||
dtsEntry ::=
|
||||
SEQUENCE {
|
||||
dtsId UInteger32,
|
||||
dtsName OctetString,
|
||||
dtsTemp Integer
|
||||
}
|
||||
|
||||
dtsId OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Temperature sensor id"
|
||||
::= { dtsEntry 1 }
|
||||
|
||||
dtsName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Name (max 20)"
|
||||
::= { dtsEntry 2 }
|
||||
|
||||
dtsTemp OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Temperature value"
|
||||
::= { dtsEntry 3 }
|
||||
|
||||
-- shuntTable
|
||||
|
||||
shuntTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF shuntEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A list of SNR-SHUNT values"
|
||||
::= { oneWire 2 }
|
||||
|
||||
shuntEntry OBJECT-TYPE
|
||||
SYNTAX shuntEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry (conceptual row) in the shuntTable"
|
||||
INDEX { pwrSensIdent }
|
||||
::= { shuntTable 1 }
|
||||
|
||||
shuntEntry ::=
|
||||
SEQUENCE {
|
||||
shuntId UInteger32,
|
||||
shuntName OctetString,
|
||||
shuntTemp Integer,
|
||||
shuntVolt Integer,
|
||||
shuntCurrent Integer,
|
||||
shuntCapacity Integer,
|
||||
shuntChrgCap Integer,
|
||||
shuntDischCap Integer,
|
||||
shuntEndOfChrg OctetString,
|
||||
shuntDiscn OctetString,
|
||||
shuntBatLive TimeTicks,
|
||||
shuntDischTime TimeTicks
|
||||
}
|
||||
|
||||
shuntId OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"SNR-SHUNT id"
|
||||
::= { shuntEntry 1 }
|
||||
|
||||
shuntName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Name (max 20)"
|
||||
::= { shuntEntry 2 }
|
||||
|
||||
shuntTemp OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Temperature value"
|
||||
::= { shuntEntry 3 }
|
||||
|
||||
shuntVolt OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Voltage"
|
||||
::= { shuntEntry 4 }
|
||||
|
||||
shuntCurrent OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Current"
|
||||
::= { shuntEntry 5 }
|
||||
|
||||
shuntChrgLvl OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Battery charge level (0..100%)"
|
||||
::= { shuntEntry 6 }
|
||||
|
||||
shuntChrgCap OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Charge capacity"
|
||||
::= { shuntEntry 7 }
|
||||
|
||||
shuntDischCap OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Discharge capacity"
|
||||
::= { shuntEntry 8 }
|
||||
|
||||
shuntEndOfChrg OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"End of charge time"
|
||||
::= { shuntEntry 9 }
|
||||
|
||||
shuntDiscn OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Disconnect time"
|
||||
::= { shuntEntry 10 }
|
||||
|
||||
shuntBatLive OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Battery using period"
|
||||
::= { shuntEntry 11 }
|
||||
|
||||
shuntDischTime OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Time to full discharge"
|
||||
::= { shuntEntry 12 }
|
||||
|
||||
|
||||
-- wirelessSensors
|
||||
|
||||
rfshtpTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF rfshtpEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A list of wireless sensors values"
|
||||
::= { measurements 10 }
|
||||
|
||||
rfshtpEntry OBJECT-TYPE
|
||||
SYNTAX rfshtpEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry (conceptual row)
|
||||
in the wrlssSensTable"
|
||||
INDEX { wrlssSensIdent }
|
||||
::= { rfshtpTable 1 }
|
||||
|
||||
rfshtpEntry ::=
|
||||
SEQUENCE {
|
||||
rfshtpId OctetString,
|
||||
rfshtpName OctetString,
|
||||
rfshtpTemp Integer,
|
||||
rfshtpHum Integer,
|
||||
rfshtpPres Integer
|
||||
}
|
||||
|
||||
rfshtpId OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Wireless sensor id"
|
||||
::= { rfshtpEntry 1 }
|
||||
|
||||
rfshtpName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Name (max 20)"
|
||||
::= { rfshtpEntry 2 }
|
||||
|
||||
rfshtpTemp OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Temperature value"
|
||||
::= { rfshtpEntry 3 }
|
||||
|
||||
rfshtpHum OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Humidity value"
|
||||
::= { rfshtpEntry 4 }
|
||||
|
||||
rfshtpPres OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Pressure value"
|
||||
::= { rfshtpEntry 5 }
|
||||
|
||||
-- sp
|
||||
|
||||
rsshtpTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF rsshtpEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "A list of SNR-RSsensor-H/T/P values"
|
||||
::= { sp 1 }
|
||||
|
||||
rsshtpEntry OBJECT-TYPE
|
||||
SYNTAX rsshtpEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "An entry (conceptual row)
|
||||
in the rsshtpTable"
|
||||
INDEX { rsshtpIdent }
|
||||
::= { rsshtpTable 1 }
|
||||
|
||||
rsshtpEntry ::= SEQUENCE
|
||||
{
|
||||
rsshtpIdent OctetString,
|
||||
rsshtpName OctetString,
|
||||
rsshtpTemp1 Integer,
|
||||
rsshtpHum Integer,
|
||||
rsshtpTemp2 Integer,
|
||||
rsshtpPssr Integer,
|
||||
}
|
||||
|
||||
rsshtpIdent OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "SNR-RSsensor-H/T/P id"
|
||||
::= { rsshtpEntry 1 }
|
||||
|
||||
rsshtpName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Name (max 20)"
|
||||
::= { rsshtpEntry 2 }
|
||||
|
||||
rsshtpTemp1 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Temperature value 1"
|
||||
::= { rsshtpEntry 3 }
|
||||
|
||||
rsshtpHum OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Humidity value"
|
||||
::= { rsshtpEntry 4 }
|
||||
|
||||
rsshtpTemp2 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Temperature value 2"
|
||||
::= { rsshtpEntry 5 }
|
||||
|
||||
rsshtpPssr OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Pressure value"
|
||||
::= { rsshtpEntry 6 }
|
||||
|
||||
|
||||
rsshtp1WTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF rsshtp1WEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "A list of temperature sensors
|
||||
are connected to SNR-RSsensor-H/T/P"
|
||||
::= { sp 100 }
|
||||
|
||||
rsshtp1WEntry OBJECT-TYPE
|
||||
SYNTAX rsshtp1WEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "An entry (conceptual row)
|
||||
in the rsshtp1WTable"
|
||||
INDEX { rsshtp1WIdent }
|
||||
::= { rsshtp1WTable 1 }
|
||||
|
||||
rsshtp1WEntry ::= SEQUENCE
|
||||
{
|
||||
rsshtp1WIdent UInteger32,
|
||||
rsshtp1WName OctetString,
|
||||
rsshtp1WTemp Integer,
|
||||
rsshtp1WMaster OctetString
|
||||
}
|
||||
|
||||
rsshtp1WIdent OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Temperature sensor id"
|
||||
::= { rsshtp1WEntry 1 }
|
||||
|
||||
rsshtp1WName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Name (max 20)"
|
||||
::= { rsshtp1WEntry 2 }
|
||||
|
||||
rsshtp1WTemp OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Temperature value"
|
||||
::= { rsshtp1WEntry 3 }
|
||||
|
||||
rsshtp1WMaster OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Name of the SNR-RSsensor-H/T/P
|
||||
which this temperature sensor
|
||||
is connected to"
|
||||
::= { rsshtp1WEntry 4 }
|
||||
|
||||
-- dio
|
||||
|
||||
diTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF diEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "A list of digital inputs values"
|
||||
::= { dio 1 }
|
||||
|
||||
diEntry OBJECT-TYPE
|
||||
SYNTAX diEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "An entry (conceptual row)
|
||||
in the diTable"
|
||||
::= { diTable 1 }
|
||||
|
||||
diEntry ::= SEQUENCE
|
||||
{
|
||||
diName OctetString,
|
||||
diAlarmName OctetString,
|
||||
diState Integer,
|
||||
diCnt Counter
|
||||
}
|
||||
|
||||
diName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Digital input name"
|
||||
::= { diEntry 1 }
|
||||
|
||||
diAlarmName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Alarm name"
|
||||
::= { diEntry 2 }
|
||||
|
||||
diState OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
low (0),
|
||||
high (1),
|
||||
off (2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Digital input state"
|
||||
::= { diEntry 3 }
|
||||
|
||||
diCnt OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Digital input impulse counter"
|
||||
::= { diEntry 4 }
|
||||
|
||||
|
||||
doTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF doEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "A list of digital outputs values"
|
||||
::= { dio 2 }
|
||||
|
||||
doEntry OBJECT-TYPE
|
||||
SYNTAX doEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "An entry (conceptual row)
|
||||
in the doTable"
|
||||
::= { doTable 1 }
|
||||
|
||||
doEntry ::= SEQUENCE
|
||||
{
|
||||
doName OctetString,
|
||||
doState Integer,
|
||||
doResetTime Integer
|
||||
}
|
||||
|
||||
doName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Digital output name"
|
||||
::= { doEntry 1 }
|
||||
|
||||
doState OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
off (0),
|
||||
on (1),
|
||||
reload (2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Digital output state"
|
||||
::= { doEntry 2 }
|
||||
|
||||
doResetDelay OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Reload period (sec)"
|
||||
::= { doEntry 3 }
|
||||
|
||||
uSenseState OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
off (0),
|
||||
on (1)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Voltage sensor state"
|
||||
::= { dio 3 }
|
||||
|
||||
-- options
|
||||
|
||||
dataType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
integer (0),
|
||||
float (1),
|
||||
ufloat (2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Values data type"
|
||||
::= { options 1 }
|
||||
|
||||
-- crit
|
||||
|
||||
tempCrit OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Critical temperature.
|
||||
From -55 to +125<32>C"
|
||||
::= { crit 10 }
|
||||
|
||||
humCrit OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Critical humidity.
|
||||
From 0 to 100%"
|
||||
::= { crit 20 }
|
||||
|
||||
adcCritMin OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "ADC IN critical min"
|
||||
::= { crit 30 }
|
||||
|
||||
adcCritMax OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "ADC IN critical max"
|
||||
::= { crit 31 }
|
||||
|
||||
-- diffparams
|
||||
|
||||
-- upsStatus
|
||||
|
||||
statusUPS OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
fail (1),
|
||||
ok (0),
|
||||
unknown (2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "UPS status"
|
||||
::= { upsStatus 1 }
|
||||
|
||||
batteryVoltageUPS OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Battery voltage value"
|
||||
::= { upsStatus 2 }
|
||||
|
||||
temperatureUPS OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Temperature value"
|
||||
::= { upsStatus 3 }
|
||||
|
||||
inputVoltageUPS OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Input voltage value"
|
||||
::= { upsStatus 4 }
|
||||
|
||||
outputVoltageUPS OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Output voltage value"
|
||||
::= { upsStatus 5 }
|
||||
|
||||
currentUPS OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Current value"
|
||||
::= { upsStatus 6 }
|
||||
|
||||
lastBatteryChangeUPS OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Last battery change date and time.
|
||||
APC only"
|
||||
::= { upsStatus 7 }
|
||||
|
||||
-- Traps
|
||||
|
||||
DI1Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Input 1 Alarm fires"
|
||||
::= { traps 1 }
|
||||
|
||||
DI1Release NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Input 1 Alarm released"
|
||||
::= { traps 2 }
|
||||
|
||||
DI2Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Input 2 Alarm fires"
|
||||
::= { traps 3 }
|
||||
|
||||
DI2Release NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Input 2 Alarm released"
|
||||
::= { traps 4 }
|
||||
|
||||
DI3Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Input 3 Alarm fires"
|
||||
::= { traps 5 }
|
||||
|
||||
DI3Release NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Input 3 Alarm released"
|
||||
::= { traps 6 }
|
||||
|
||||
DI4Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Input 4 Alarm fires"
|
||||
::= { traps 7 }
|
||||
|
||||
DI4Release NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Input 4 Alarm released"
|
||||
::= { traps 8 }
|
||||
|
||||
DI5Alarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Input 5 Alarm fires"
|
||||
::= { traps 9 }
|
||||
|
||||
DI5Release NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Input 5 Alarm released"
|
||||
::= { traps 10 }
|
||||
|
||||
uSenseAlarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Signifies that Phase sensor
|
||||
Alarm fires"
|
||||
::= { traps 11 }
|
||||
|
||||
uSenseRelease NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Signifies that Phase sensor
|
||||
Alarm released"
|
||||
::= { traps 12 }
|
||||
|
||||
reloutOn NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Signifies that Rele was swithed on
|
||||
by Thermostat or Gigrostat mode"
|
||||
::= { traps 13 }
|
||||
|
||||
reloutOff NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Signifies that Rele was swithed off
|
||||
by Thermostat or Gigrostat mode"
|
||||
::= { traps 14 }
|
||||
|
||||
DO1On NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Signifies that Output 1 was swithed on
|
||||
by Thermostat or Gigrostat mode"
|
||||
::= { traps 15 }
|
||||
|
||||
DO1Off NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Signifies that Output 1 was swithed off
|
||||
by Thermostat or Gigrostat mode"
|
||||
::= { traps 16 }
|
||||
|
||||
DO2On NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Signifies that Output 2 was swithed on
|
||||
by Thermostat or Gigrostat mode"
|
||||
::= { traps 17 }
|
||||
|
||||
DO2Off NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Signifies that Output 2 was swithed off
|
||||
by Thermostat or Gigrostat mode"
|
||||
::= { traps 18 }
|
||||
|
||||
DO3On NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Signifies that Output 3 was swithed on
|
||||
by Thermostat or Gigrostat mode"
|
||||
::= { traps 19 }
|
||||
|
||||
DO3Off NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Signifies that Output 3 was swithed off
|
||||
by Thermostat or Gigrostat mode"
|
||||
::= { traps 20 }
|
||||
|
||||
DO4On NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Signifies that Output 4 was swithed on
|
||||
by Thermostat or Gigrostat mode"
|
||||
::= { traps 21 }
|
||||
|
||||
DO4Off NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Signifies that Output 4 was swithed off
|
||||
by Thermostat or Gigrostat mode"
|
||||
::= { traps 22 }
|
||||
|
||||
DO5On NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Signifies that Output 5 was swithed on
|
||||
by Thermostat or Gigrostat mode"
|
||||
::= { traps 23 }
|
||||
|
||||
DO5Off NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Signifies that Output 5 was swithed off
|
||||
by Thermostat or Gigrostat mode"
|
||||
::= { traps 24 }
|
||||
|
||||
tempSensorAlarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Temperature alarm"
|
||||
::= { traps 29 }
|
||||
|
||||
tempSensorRelease NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Temperature release"
|
||||
::= { traps 30 }
|
||||
|
||||
adcSensorAlarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Voltage sensor alarm"
|
||||
::= { traps 31 }
|
||||
|
||||
adcSensorRelease NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Voltage sensor release"
|
||||
::= { traps 32 }
|
||||
|
||||
humSensorAlarm NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Humidity alarm"
|
||||
::= { traps 33 }
|
||||
|
||||
humSensorRelease NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Humidity release"
|
||||
::= { traps 34 }
|
||||
|
||||
task1Done NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Task 1 done"
|
||||
::= { traps 36 }
|
||||
|
||||
task2Done NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Task 2 done"
|
||||
::= { traps 37 }
|
||||
|
||||
task3Done NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Task 3 done"
|
||||
::= { traps 38 }
|
||||
|
||||
task4Done NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Task 4 done"
|
||||
::= { traps 39 }
|
||||
|
||||
pingLost NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Ping lost"
|
||||
::= { traps 45 }
|
||||
|
||||
batteryChargeLow NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "Battery charge is low"
|
||||
::= { traps 47 }
|
||||
|
||||
upsUtilityFail NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "UPS utility fail"
|
||||
::= { traps 50 }
|
||||
|
||||
upsUtilityOk NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION "UPS utility OK"
|
||||
::= { traps 51 }
|
||||
|
||||
-- erd4Group
|
||||
|
||||
erd4Group NOTIFICATION-GROUP
|
||||
NOTIFICATIONS
|
||||
{
|
||||
DI1Alarm,
|
||||
DI1Release,
|
||||
DI2Alarm,
|
||||
DI2Release,
|
||||
DI3Alarm,
|
||||
DI3Release,
|
||||
DI4Alarm,
|
||||
DI4Release,
|
||||
DI5Alarm,
|
||||
DI5Release,
|
||||
uSenseAlarm,
|
||||
uSenseRelease,
|
||||
reloutOn,
|
||||
reloutOff,
|
||||
DO1On,
|
||||
DO1Off,
|
||||
DO2On,
|
||||
DO2Off,
|
||||
DO3On,
|
||||
DO3Off,
|
||||
DO4On,
|
||||
DO4Off,
|
||||
DO5On,
|
||||
DO5Off,
|
||||
tempSensorAlarm,
|
||||
tempSensorRelease,
|
||||
adcSensorAlarm,
|
||||
adcSensorRelease,
|
||||
humSensorAlarm,
|
||||
humSensorRelease,
|
||||
task1Done,
|
||||
task2Done,
|
||||
task3Done,
|
||||
task4Done,
|
||||
pingLost,
|
||||
batteryChargeLow,
|
||||
upsUtilityFail,
|
||||
upsUtilityOk
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION "Notifications"
|
||||
::= { snr-erd-project 99 }
|
||||
|
||||
END
|
25325
mibs/snr/SNR-SWITCH-MIB
Normal file
25325
mibs/snr/SNR-SWITCH-MIB
Normal file
File diff suppressed because it is too large
Load Diff
Reference in New Issue
Block a user