POWER-ATTRIBUTES-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE,
|
||||
mib-2,
|
||||
Integer32, Unsigned32
|
||||
FROM SNMPv2-SMI
|
||||
MODULE-COMPLIANCE,
|
||||
OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
UnitMultiplier
|
||||
FROM ENERGY-OBJECT-MIB
|
||||
entPhysicalIndex
|
||||
FROM ENTITY-MIB;
|
||||
|
||||
powerAttributesMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "201502090000Z" -- 9 February 2015
|
||||
ORGANIZATION "IETF EMAN Working Group"
|
||||
CONTACT-INFO
|
||||
"WG charter:
|
||||
http://datatracker.ietf.org/wg/eman/charter/
|
||||
|
||||
Mailing Lists:
|
||||
General Discussion: eman@ietf.org
|
||||
|
||||
To Subscribe:
|
||||
https://www.ietf.org/mailman/listinfo/eman
|
||||
|
||||
Archive:
|
||||
http://www.ietf.org/mail-archive/web/eman
|
||||
|
||||
Editors:
|
||||
|
||||
Mouli Chandramouli
|
||||
Cisco Systems, Inc.
|
||||
Sarjapur Outer Ring Road
|
||||
Bangalore 560103
|
||||
India
|
||||
Phone: +91 80 4429 2409
|
||||
Email: moulchan@cisco.com
|
||||
|
||||
Brad Schoening
|
||||
44 Rivers Edge Drive
|
||||
Little Silver, NJ 07739
|
||||
United States
|
||||
Email: brad.schoening@verizon.net
|
||||
|
||||
Juergen Quittek
|
||||
NEC Europe Ltd.
|
||||
NEC Laboratories Europe
|
||||
Network Research Division
|
||||
Kurfuersten-Anlage 36
|
||||
Heidelberg 69115
|
||||
Germany
|
||||
Phone: +49 6221 4342-115
|
||||
Email: quittek@neclab.eu
|
||||
|
||||
Thomas Dietz
|
||||
NEC Europe Ltd.
|
||||
NEC Laboratories Europe
|
||||
Network Research Division
|
||||
Kurfuersten-Anlage 36
|
||||
69115 Heidelberg
|
||||
Germany
|
||||
Phone: +49 6221 4342-128
|
||||
Email: Thomas.Dietz@nw.neclab.eu
|
||||
|
||||
Benoit Claise
|
||||
Cisco Systems, Inc.
|
||||
De Kleetlaan 6a b1
|
||||
Degem 1831
|
||||
Belgium
|
||||
Phone: +32 2 704 5622
|
||||
Email: bclaise@cisco.com"
|
||||
DESCRIPTION
|
||||
"Copyright (c) 2015 IETF Trust and the persons identified as
|
||||
authors of the code. All rights reserved.
|
||||
|
||||
Redistribution and use in source and binary forms, with or
|
||||
without modification, is permitted pursuant to, and subject
|
||||
to the license terms contained in, the Simplified BSD License
|
||||
set forth in Section 4.c of the IETF Trust's Legal Provisions
|
||||
Relating to IETF Documents
|
||||
(http://trustee.ietf.org/license-info).
|
||||
|
||||
This MIB is used to report AC power attributes in devices.
|
||||
The table is a sparse augmentation of the eoPowerTable table
|
||||
from the energyObjectMib module. Both three-phase and
|
||||
single-phase power configurations are supported.
|
||||
|
||||
As a requirement for this MIB module, RFC 7461 SHOULD be
|
||||
implemented.
|
||||
|
||||
Module Compliance of ENTITY-MIB v4 with respect to
|
||||
entity4CRCompliance MUST be supported which requires
|
||||
implementation of four MIB objects: entPhysicalIndex,
|
||||
entPhysicalClass, entPhysicalName, and entPhysicalUUID."
|
||||
REVISION "201502090000Z" -- 9 February 2015
|
||||
DESCRIPTION
|
||||
"Initial version, published as RFC 7460"
|
||||
::= { mib-2 230 }
|
||||
|
||||
powerAttributesMIBConform OBJECT IDENTIFIER
|
||||
::= { powerAttributesMIB 0 }
|
||||
|
||||
powerAttributesMIBObjects OBJECT IDENTIFIER
|
||||
::= { powerAttributesMIB 1 }
|
||||
|
||||
-- Objects
|
||||
|
||||
eoACPwrAttributesTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EoACPwrAttributesEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains power attributes measurements for
|
||||
supported entPhysicalIndex entities. It is a sparse
|
||||
extension of the eoPowerTable."
|
||||
::= { powerAttributesMIBObjects 1 }
|
||||
|
||||
eoACPwrAttributesEntry OBJECT-TYPE
|
||||
SYNTAX EoACPwrAttributesEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is a sparse extension of the eoPowerTable with
|
||||
entries for power attributes measurements or
|
||||
configuration. Each measured value corresponds to an
|
||||
attribute in IEC 61850-7-4 for non-phase measurements
|
||||
within the object MMXN."
|
||||
INDEX { entPhysicalIndex }
|
||||
::= { eoACPwrAttributesTable 1 }
|
||||
|
||||
EoACPwrAttributesEntry ::= SEQUENCE {
|
||||
eoACPwrAttributesConfiguration INTEGER,
|
||||
eoACPwrAttributesAvgVoltage Integer32,
|
||||
eoACPwrAttributesAvgCurrent Unsigned32,
|
||||
eoACPwrAttributesFrequency Integer32,
|
||||
eoACPwrAttributesPowerUnitMultiplier UnitMultiplier,
|
||||
eoACPwrAttributesPowerAccuracy Integer32,
|
||||
eoACPwrAttributesTotalActivePower Integer32,
|
||||
eoACPwrAttributesTotalReactivePower Integer32,
|
||||
eoACPwrAttributesTotalApparentPower Integer32,
|
||||
eoACPwrAttributesTotalPowerFactor Integer32,
|
||||
eoACPwrAttributesThdCurrent Integer32,
|
||||
eoACPwrAttributesThdVoltage Integer32
|
||||
}
|
||||
|
||||
eoACPwrAttributesConfiguration OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
sngl(1),
|
||||
del(2),
|
||||
wye(3)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Configuration describes the physical configurations of
|
||||
the power supply lines:
|
||||
|
||||
* alternating current, single phase (SNGL)
|
||||
* alternating current, three-phase delta (DEL)
|
||||
* alternating current, three-phase Y (WYE)
|
||||
|
||||
Three-phase configurations can be either connected in a
|
||||
triangular delta (DEL) or star Y (WYE) system. WYE
|
||||
systems have a shared neutral voltage, while DEL systems
|
||||
do not. Each phase is offset 120 degrees to each other."
|
||||
::= { eoACPwrAttributesEntry 1 }
|
||||
|
||||
eoACPwrAttributesAvgVoltage OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "0.1 Volt AC"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A measured value for average of the voltage measured
|
||||
over an integral number of AC cycles. For a three-phase
|
||||
system, this is the average voltage (V1+V2+V3)/3. IEC
|
||||
61850-7-4 measured value attribute 'Vol'."
|
||||
::= { eoACPwrAttributesEntry 2 }
|
||||
|
||||
eoACPwrAttributesAvgCurrent OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
UNITS "amperes"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A measured value for average of the current measured
|
||||
over an integral number of AC cycles. For a three-phase
|
||||
system, this is the average current (I1+I2+I3)/3. IEC
|
||||
61850-7-4 attribute 'Amp'."
|
||||
::= { eoACPwrAttributesEntry 3 }
|
||||
|
||||
eoACPwrAttributesFrequency OBJECT-TYPE
|
||||
SYNTAX Integer32 (4500..6500)
|
||||
UNITS "0.01 hertz"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A measured value for the basic frequency of the AC
|
||||
circuit. IEC 61850-7-4 attribute 'Hz'."
|
||||
::= { eoACPwrAttributesEntry 4 }
|
||||
|
||||
eoACPwrAttributesPowerUnitMultiplier OBJECT-TYPE
|
||||
SYNTAX UnitMultiplier
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The magnitude of watts for the usage value in
|
||||
eoACPwrAttributesTotalActivePower,
|
||||
eoACPwrAttributesTotalReactivePower,
|
||||
and eoACPwrAttributesTotalApparentPower measurements.
|
||||
For three-phase power systems, this will also include
|
||||
eoACPwrAttributesWyeActivePower,
|
||||
eoACPwrAttributesWyeReactivePower, and
|
||||
eoACPwrAttributesWyeApparentPower."
|
||||
::= { eoACPwrAttributesEntry 5 }
|
||||
|
||||
eoACPwrAttributesPowerAccuracy OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..10000)
|
||||
UNITS "hundredths of percent"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates a percentage value, in hundredths of a
|
||||
percent, representing the presumed accuracy of active,
|
||||
reactive, and apparent power usage reporting. For
|
||||
example, 1010 means the reported usage is accurate to +/-
|
||||
10.1 percent. This value is zero if the accuracy is
|
||||
unknown.
|
||||
|
||||
ANSI and IEC define the following accuracy classes for
|
||||
power measurement: IEC 62053-22 & 60044-1 class 0.1, 0.2,
|
||||
0.5, 1, & 3.
|
||||
ANSI C12.20 class 0.2 & 0.5"
|
||||
::= { eoACPwrAttributesEntry 6 }
|
||||
|
||||
eoACPwrAttributesTotalActivePower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "watts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A measured value of the actual power delivered to or
|
||||
consumed by the load. IEC 61850-7-4 attribute 'TotW'."
|
||||
::= { eoACPwrAttributesEntry 7 }
|
||||
|
||||
eoACPwrAttributesTotalReactivePower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "volt-amperes reactive"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A measured value of the reactive portion of the apparent
|
||||
power. IEC 61850-7-4 attribute 'TotVAr'."
|
||||
::= { eoACPwrAttributesEntry 8 }
|
||||
|
||||
eoACPwrAttributesTotalApparentPower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "volt-amperes"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A measured value of the voltage and current that
|
||||
determines the apparent power. The apparent power is the
|
||||
vector sum of real and reactive power.
|
||||
|
||||
Note: watts and volt-amperes are equivalent units and may
|
||||
be combined. IEC 61850-7-4 attribute 'TotVA'."
|
||||
::= { eoACPwrAttributesEntry 9 }
|
||||
|
||||
eoACPwrAttributesTotalPowerFactor OBJECT-TYPE
|
||||
SYNTAX Integer32 (-10000..10000)
|
||||
UNITS "hundredths"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A measured value ratio of the real power flowing to the
|
||||
load versus the apparent power. It is dimensionless and
|
||||
expressed here as a percentage value in hundredths. A power
|
||||
factor of 100% indicates there is no inductance load and
|
||||
thus no reactive power. A Power Factor can be positive or
|
||||
negative, where the sign should be in lead/lag (IEEE)
|
||||
form. IEC 61850-7-4 attribute 'TotPF'."
|
||||
::= { eoACPwrAttributesEntry 10 }
|
||||
|
||||
eoACPwrAttributesThdCurrent OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..10000)
|
||||
UNITS "hundredths of percent"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A calculated value for the current total harmonic
|
||||
distortion (THD). Method of calculation is not
|
||||
specified. IEC 61850-7-4 attribute 'ThdAmp'."
|
||||
::= { eoACPwrAttributesEntry 11 }
|
||||
|
||||
eoACPwrAttributesThdVoltage OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..10000)
|
||||
UNITS "hundredths of percent"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A calculated value for the voltage total harmonic
|
||||
distortion (THD). The method of calculation is not
|
||||
specified. IEC 61850-7-4 attribute 'ThdVol'."
|
||||
::= { eoACPwrAttributesEntry 12 }
|
||||
|
||||
eoACPwrAttributesDelPhaseTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EoACPwrAttributesDelPhaseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This optional table describes three-phase power attributes
|
||||
measurements in a DEL configuration with phase-to-phase
|
||||
|
||||
power attributes measurements. Entities having single
|
||||
phase power shall not have any entities. This is a
|
||||
sparse extension of the eoACPwrAttributesTable.
|
||||
|
||||
These attributes correspond to measurements related to
|
||||
the IEC 61850-7.4 MMXU phase and measured harmonic or
|
||||
interharmonics related to the MHAI phase."
|
||||
::= { powerAttributesMIBObjects 2 }
|
||||
|
||||
eoACPwrAttributesDelPhaseEntry OBJECT-TYPE
|
||||
SYNTAX EoACPwrAttributesDelPhaseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry describes power measurements of a phase in a
|
||||
DEL three-phase power. Three entries are required for each
|
||||
supported entPhysicalIndex entry. Voltage measurements
|
||||
are provided relative to each other.
|
||||
|
||||
For phase-to-phase measurements, the
|
||||
eoACPwrAttributesDelPhaseIndex is compared against the
|
||||
following phase at +120 degrees. Thus, the possible
|
||||
values are:
|
||||
|
||||
eoACPwrAttributesDelPhaseIndex Next Phase Angle
|
||||
0 120
|
||||
120 240
|
||||
240 0
|
||||
"
|
||||
INDEX { entPhysicalIndex, eoACPwrAttributesDelPhaseIndex }
|
||||
::= { eoACPwrAttributesDelPhaseTable 1}
|
||||
|
||||
EoACPwrAttributesDelPhaseEntry ::= SEQUENCE {
|
||||
eoACPwrAttributesDelPhaseIndex Integer32,
|
||||
eoACPwrAttributesDelPhaseToNextPhaseVoltage Integer32,
|
||||
eoACPwrAttributesDelThdPhaseToNextPhaseVoltage Integer32
|
||||
}
|
||||
|
||||
eoACPwrAttributesDelPhaseIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..359)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A phase angle typically corresponding to 0, 120, 240."
|
||||
::= { eoACPwrAttributesDelPhaseEntry 1 }
|
||||
|
||||
eoACPwrAttributesDelPhaseToNextPhaseVoltage OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "0.1 Volt AC"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A measured value of phase to next phase voltages, where
|
||||
the next phase is IEC 61850-7-4 attribute 'PPV'."
|
||||
::= { eoACPwrAttributesDelPhaseEntry 2 }
|
||||
|
||||
eoACPwrAttributesDelThdPhaseToNextPhaseVoltage OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..10000)
|
||||
UNITS "hundredths of percent"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A calculated value for the voltage total harmonic
|
||||
distortion for phase to next phase. Method of calculation
|
||||
is not specified. IEC 61850-7-4 attribute 'ThdPPV'."
|
||||
::= { eoACPwrAttributesDelPhaseEntry 3 }
|
||||
|
||||
eoACPwrAttributesWyePhaseTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EoACPwrAttributesWyePhaseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This optional table describes three-phase power attributes
|
||||
measurements in a WYE configuration with phase-to-neutral
|
||||
power attributes measurements. Entities having single
|
||||
phase power shall not have any entities. This is a sparse
|
||||
extension of the eoACPwrAttributesTable.
|
||||
|
||||
These attributes correspond to measurements related to
|
||||
the IEC 61850-7.4 MMXU phase and measured harmonic or
|
||||
interharmonics related to the MHAI phase."
|
||||
::= { powerAttributesMIBObjects 3 }
|
||||
|
||||
eoACPwrAttributesWyePhaseEntry OBJECT-TYPE
|
||||
SYNTAX EoACPwrAttributesWyePhaseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table describes measurements of a phase in a WYE
|
||||
three-phase power system. Three entries are required for
|
||||
each supported entPhysicalIndex entry. Voltage
|
||||
measurements are relative to neutral.
|
||||
|
||||
Each entry describes power attributes of one phase of a
|
||||
WYE three-phase power system."
|
||||
INDEX { entPhysicalIndex, eoACPwrAttributesWyePhaseIndex }
|
||||
::= { eoACPwrAttributesWyePhaseTable 1}
|
||||
|
||||
EoACPwrAttributesWyePhaseEntry ::= SEQUENCE {
|
||||
eoACPwrAttributesWyePhaseIndex Integer32,
|
||||
eoACPwrAttributesWyePhaseToNeutralVoltage Integer32,
|
||||
eoACPwrAttributesWyeCurrent Integer32,
|
||||
eoACPwrAttributesWyeActivePower Integer32,
|
||||
eoACPwrAttributesWyeReactivePower Integer32,
|
||||
eoACPwrAttributesWyeApparentPower Integer32,
|
||||
eoACPwrAttributesWyePowerFactor Integer32,
|
||||
eoACPwrAttributesWyeThdCurrent Integer32,
|
||||
eoACPwrAttributesWyeThdPhaseToNeutralVoltage Integer32
|
||||
}
|
||||
|
||||
eoACPwrAttributesWyePhaseIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..359)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A phase angle typically corresponding to 0, 120, 240."
|
||||
::= { eoACPwrAttributesWyePhaseEntry 1 }
|
||||
|
||||
eoACPwrAttributesWyePhaseToNeutralVoltage OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "0.1 Volt AC"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A measured value of phase to neutral voltage. IEC
|
||||
61850-7-4 attribute 'PNV'."
|
||||
::= { eoACPwrAttributesWyePhaseEntry 2 }
|
||||
|
||||
eoACPwrAttributesWyeCurrent OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "0.1 amperes AC"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A measured value of phase currents. IEC 61850-7-4
|
||||
attribute 'A'."
|
||||
::= { eoACPwrAttributesWyePhaseEntry 3 }
|
||||
|
||||
eoACPwrAttributesWyeActivePower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "watts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A measured value of the actual power delivered to or
|
||||
consumed by the load with the magnitude indicated
|
||||
separately in eoPowerUnitMultiplier. IEC 61850-7-4
|
||||
attribute 'W'."
|
||||
::= { eoACPwrAttributesWyePhaseEntry 4 }
|
||||
|
||||
eoACPwrAttributesWyeReactivePower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "volt-amperes reactive"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A measured value of the reactive portion of the apparent
|
||||
power with the magnitude of indicated separately in
|
||||
eoPowerUnitMultiplier. IEC 61850-7-4 attribute 'VAr'."
|
||||
::= { eoACPwrAttributesWyePhaseEntry 5 }
|
||||
|
||||
eoACPwrAttributesWyeApparentPower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "volt-amperes"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A measured value of the voltage and current determines
|
||||
the apparent power with the indicated separately in
|
||||
eoPowerUnitMultiplier. Active plus reactive power equals
|
||||
the total apparent power.
|
||||
|
||||
Note: Watts and volt-amperes are equivalent units and may
|
||||
be combined. IEC 61850-7-4 attribute 'VA'."
|
||||
::= { eoACPwrAttributesWyePhaseEntry 6 }
|
||||
|
||||
eoACPwrAttributesWyePowerFactor OBJECT-TYPE
|
||||
SYNTAX Integer32 (-10000..10000)
|
||||
UNITS "hundredths"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A measured value ratio of the real power flowing to the
|
||||
load versus the apparent power for this phase. IEC
|
||||
61850-7-4 attribute 'PF'. Power Factor can be positive or
|
||||
negative where the sign should be in lead/lag (IEEE)
|
||||
form."
|
||||
::= { eoACPwrAttributesWyePhaseEntry 7 }
|
||||
|
||||
eoACPwrAttributesWyeThdCurrent OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..10000)
|
||||
UNITS "hundredths of percent"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A calculated value for the voltage total harmonic
|
||||
distortion (THD) for phase to phase. Method of
|
||||
calculation is not specified.
|
||||
IEC 61850-7-4 attribute 'ThdA'."
|
||||
::= { eoACPwrAttributesWyePhaseEntry 8 }
|
||||
|
||||
eoACPwrAttributesWyeThdPhaseToNeutralVoltage OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..10000)
|
||||
UNITS "hundredths of percent"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A calculated value of the voltage total harmonic
|
||||
distortion (THD) for phase to neutral. IEC 61850-7-4
|
||||
attribute 'ThdPhV'."
|
||||
::= { eoACPwrAttributesWyePhaseEntry 9 }
|
||||
|
||||
-- Conformance
|
||||
powerAttributesMIBCompliances OBJECT IDENTIFIER
|
||||
::= { powerAttributesMIB 2 }
|
||||
|
||||
powerAttributesMIBGroups OBJECT IDENTIFIER
|
||||
::= { powerAttributesMIB 3 }
|
||||
|
||||
powerAttributesMIBFullCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"When this MIB is implemented with support for read-
|
||||
create, then such an implementation can claim full
|
||||
compliance. Such devices can then be both monitored and
|
||||
configured with this MIB.
|
||||
|
||||
Module Compliance of RFC 6933 with respect to
|
||||
entity4CRCompliance MUST be supported which requires
|
||||
implementation of four MIB objects: entPhysicalIndex,
|
||||
entPhysicalClass, entPhysicalName, and entPhysicalUUID."
|
||||
REFERENCE
|
||||
"RFC 6933: Entity MIB (Version 4)"
|
||||
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS {
|
||||
powerACPwrAttributesMIBTableGroup
|
||||
}
|
||||
|
||||
GROUP powerACPwrAttributesOptionalMIBTableGroup
|
||||
DESCRIPTION
|
||||
"A compliant implementation does not have
|
||||
to implement."
|
||||
|
||||
GROUP powerACPwrAttributesDelPhaseMIBTableGroup
|
||||
DESCRIPTION
|
||||
"A compliant implementation does not have to implement."
|
||||
|
||||
GROUP powerACPwrAttributesWyePhaseMIBTableGroup
|
||||
DESCRIPTION
|
||||
"A compliant implementation does not have to implement."
|
||||
::= { powerAttributesMIBCompliances 1 }
|
||||
|
||||
-- Units of Conformance
|
||||
|
||||
powerACPwrAttributesMIBTableGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
-- Note that object entPhysicalIndex is NOT
|
||||
-- included since it is not-accessible
|
||||
eoACPwrAttributesAvgVoltage,
|
||||
eoACPwrAttributesAvgCurrent,
|
||||
eoACPwrAttributesFrequency,
|
||||
eoACPwrAttributesPowerUnitMultiplier,
|
||||
eoACPwrAttributesPowerAccuracy,
|
||||
eoACPwrAttributesTotalActivePower,
|
||||
eoACPwrAttributesTotalReactivePower,
|
||||
eoACPwrAttributesTotalApparentPower,
|
||||
eoACPwrAttributesTotalPowerFactor
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This group contains the collection of all the power
|
||||
attributes objects related to the Energy Object."
|
||||
::= { powerAttributesMIBGroups 1 }
|
||||
|
||||
powerACPwrAttributesOptionalMIBTableGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
eoACPwrAttributesConfiguration,
|
||||
eoACPwrAttributesThdCurrent,
|
||||
eoACPwrAttributesThdVoltage
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This group contains the collection of all the power
|
||||
attributes objects related to the Energy Object."
|
||||
::= { powerAttributesMIBGroups 2 }
|
||||
|
||||
powerACPwrAttributesDelPhaseMIBTableGroup OBJECT-GROUP
|
||||
|
||||
OBJECTS {
|
||||
-- Note that object entPhysicalIndex and
|
||||
-- eoACPwrAttributesDelPhaseIndex are NOT
|
||||
-- included since they are not-accessible
|
||||
eoACPwrAttributesDelPhaseToNextPhaseVoltage,
|
||||
eoACPwrAttributesDelThdPhaseToNextPhaseVoltage
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This group contains the collection of all power
|
||||
attributes of a phase in a DEL three-phase power system."
|
||||
::= { powerAttributesMIBGroups 3 }
|
||||
|
||||
powerACPwrAttributesWyePhaseMIBTableGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
-- Note that object entPhysicalIndex and
|
||||
-- eoACPwrAttributesWyePhaseIndex are NOT
|
||||
-- included since they are not-accessible
|
||||
eoACPwrAttributesWyePhaseToNeutralVoltage,
|
||||
eoACPwrAttributesWyeCurrent,
|
||||
eoACPwrAttributesWyeActivePower,
|
||||
eoACPwrAttributesWyeReactivePower,
|
||||
eoACPwrAttributesWyeApparentPower,
|
||||
eoACPwrAttributesWyePowerFactor,
|
||||
eoACPwrAttributesWyeThdPhaseToNeutralVoltage,
|
||||
eoACPwrAttributesWyeThdCurrent
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This group contains the collection of all power
|
||||
attributes of a phase in a WYE three-phase power system."
|
||||
::= { powerAttributesMIBGroups 4 }
|
||||
|
||||