initial commit; version 22.5.12042
This commit is contained in:
729
mibs/rfc/IEEE8021-ST-MIB
Normal file
729
mibs/rfc/IEEE8021-ST-MIB
Normal file
@ -0,0 +1,729 @@
|
||||
IEEE8021-ST-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- =============================================================
|
||||
-- MIB for support of the Scheduled Traffic Enhancements
|
||||
-- for IEEE 802.1Q Bridges.
|
||||
-- =============================================================
|
||||
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE,
|
||||
Unsigned32,
|
||||
Counter64
|
||||
FROM SNMPv2-SMI
|
||||
TEXTUAL-CONVENTION,
|
||||
TruthValue
|
||||
FROM SNMPv2-TC
|
||||
MODULE-COMPLIANCE,
|
||||
OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
ieee802dot1mibs
|
||||
FROM IEEE8021-TC-MIB
|
||||
ieee8021BridgeBaseComponentId,
|
||||
ieee8021BridgeBasePort
|
||||
FROM IEEE8021-BRIDGE-MIB
|
||||
;
|
||||
|
||||
ieee8021STMib MODULE-IDENTITY
|
||||
LAST-UPDATED "201806210000Z" -- June 21, 2018
|
||||
ORGANIZATION "IEEE 802.1 Working Group"
|
||||
CONTACT-INFO
|
||||
" WG-URL: http://www.ieee802.org/1/
|
||||
WG-EMail: stds-802-1-L@ieee.org
|
||||
|
||||
Contact: IEEE 802.1 Working Group Chair
|
||||
Postal: C/O IEEE 802.1 Working Group
|
||||
IEEE Standards Association
|
||||
445 Hoes Lane
|
||||
Piscataway
|
||||
NJ 08854
|
||||
USA
|
||||
E-mail: stds-802-1-L@ieee.org"
|
||||
DESCRIPTION
|
||||
"The Bridge MIB module for managing devices that support
|
||||
the Scheduled Traffic Enhancements
|
||||
for IEEE 802.1Q Bridges.
|
||||
|
||||
Unless otherwise indicated, the references in this MIB
|
||||
module are to IEEE Std 802.1Q.
|
||||
|
||||
Copyright (C) IEEE (2018).
|
||||
This version of this MIB module is part of IEEE Std 802.1Q;
|
||||
see the draft itself for full legal notices."
|
||||
|
||||
REVISION "201806210000Z" -- June 21, 2018
|
||||
DESCRIPTION
|
||||
"Published as part of IEEE Std 802.1Q 2017 revision.
|
||||
Cross references updated and corrected."
|
||||
|
||||
REVISION "201608150000Z" -- August 15, 2016
|
||||
DESCRIPTION
|
||||
"Revised to include Set-And-Hold-MAC and
|
||||
Set-And-Release-MAC in the description of
|
||||
ieee8021STAdminControlList and
|
||||
ieee8021STOperControlList.
|
||||
Published as part of IEEE Std 802.1Qbu."
|
||||
|
||||
REVISION "201602190000Z" -- February 19, 2016
|
||||
DESCRIPTION
|
||||
"Initial version published as part of IEEE Std 802.1Qbv."
|
||||
|
||||
::= { ieee802dot1mibs 30 }
|
||||
|
||||
-- =============================================================
|
||||
-- Textual Conventions
|
||||
-- =============================================================
|
||||
|
||||
IEEE8021STTrafficClassValue ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "d"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A traffic class value.
|
||||
This is the numerical value associated with a traffic
|
||||
class in a Bridge. Larger values are associated with
|
||||
higher priority traffic classes."
|
||||
REFERENCE "12.29.1"
|
||||
SYNTAX Unsigned32 (0..7)
|
||||
|
||||
IEEE8021STPTPtimeValue ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A PTPtime value, represented as a 48-bit unsigned integer
|
||||
number of seconds and a 32-bit unsigned integer number of
|
||||
nanoseconds.
|
||||
The first 6 octets represent the number of seconds: the
|
||||
first octet is the most significant
|
||||
octet of the 48-bit seconds value and the sixth octet
|
||||
is the least significant octet of the seconds value.
|
||||
The remaining octets, 7 through 10, represent the
|
||||
number of nanoseconds: the seventh octet
|
||||
is the most significant octet of the 32-bit nanoseconds
|
||||
value and the tenth octet is the
|
||||
least significant octet of the nanoseconds value."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
SYNTAX OCTET STRING (SIZE(10))
|
||||
|
||||
|
||||
-- =============================================================
|
||||
-- subtrees in the ST MIB
|
||||
-- =============================================================
|
||||
|
||||
ieee8021STNotifications
|
||||
OBJECT IDENTIFIER ::= { ieee8021STMib 0 }
|
||||
|
||||
ieee8021STObjects
|
||||
OBJECT IDENTIFIER ::= { ieee8021STMib 1 }
|
||||
|
||||
ieee8021STConformance
|
||||
OBJECT IDENTIFIER ::= { ieee8021STMib 2 }
|
||||
|
||||
ieee8021STMaxSDUSubtree
|
||||
OBJECT IDENTIFIER ::= { ieee8021STObjects 1 }
|
||||
|
||||
ieee8021STParameters
|
||||
OBJECT IDENTIFIER ::= { ieee8021STObjects 2 }
|
||||
|
||||
-- =============================================================
|
||||
-- The ieee8021STMaxSDUSubtree subtree
|
||||
-- This subtree defines the objects necessary for the management
|
||||
-- of the max SDU size parameters for each traffic class on a Port.
|
||||
-- =============================================================
|
||||
|
||||
-- =============================================================
|
||||
-- the ieee8021STMaxSDUTable
|
||||
-- =============================================================
|
||||
|
||||
ieee8021STMaxSDUTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF Ieee8021STMaxSDUEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table containing a set of max SDU
|
||||
parameters, one for each traffic class.
|
||||
All writeable objects in this table must be
|
||||
persistent over power up restart/reboot."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STMaxSDUSubtree 1 }
|
||||
|
||||
ieee8021STMaxSDUEntry OBJECT-TYPE
|
||||
SYNTAX Ieee8021STMaxSDUEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A list of objects containing Max SDU size
|
||||
for each traffic class supported by the Port."
|
||||
INDEX { ieee8021BridgeBaseComponentId,
|
||||
ieee8021BridgeBasePort,
|
||||
ieee8021STTrafficClass }
|
||||
::= { ieee8021STMaxSDUTable 1 }
|
||||
|
||||
Ieee8021STMaxSDUEntry ::=
|
||||
SEQUENCE {
|
||||
ieee8021STTrafficClass
|
||||
IEEE8021STTrafficClassValue,
|
||||
ieee8021STMaxSDU
|
||||
Unsigned32,
|
||||
ieee8021TransmissionOverrun
|
||||
Counter64
|
||||
}
|
||||
|
||||
ieee8021STTrafficClass OBJECT-TYPE
|
||||
SYNTAX IEEE8021STTrafficClassValue
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The traffic class number associated with the row of
|
||||
the table.
|
||||
|
||||
A row in this table is created for each traffic class
|
||||
that is supported by the Port"
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STMaxSDUEntry 1 }
|
||||
|
||||
|
||||
ieee8021STMaxSDU OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
UNITS "octets"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of the MaxSDU parameter for the traffic class.
|
||||
This value is represented as an unsigned integer. A value
|
||||
of 0 is interpreted as the max SDU size supported by
|
||||
the underlying MAC.
|
||||
|
||||
The default value of the MaxSDU parameter is 0.
|
||||
|
||||
The value of this object MUST be retained across
|
||||
reinitializations of the management system."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
DEFVAL { 0 }
|
||||
::= { ieee8021STMaxSDUEntry 2}
|
||||
|
||||
|
||||
ieee8021TransmissionOverrun OBJECT-TYPE
|
||||
SYNTAX Counter64
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A counter of transmission overrun events, where
|
||||
a PDU is still being transmitted by a MAC at the
|
||||
time when the transmission gate for the queue closed."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1, 12.29.1.1.2"
|
||||
DEFVAL { 0 }
|
||||
::= { ieee8021STMaxSDUEntry 3}
|
||||
|
||||
|
||||
-- =============================================================
|
||||
-- The ieee8021STParameters subtree
|
||||
-- This subtree defines the objects necessary for the management
|
||||
-- of the traffic scheduling mechanism for IEEE Std 802.1Q.
|
||||
-- =============================================================
|
||||
|
||||
-- =============================================================
|
||||
-- the ieee8021STParametersTable
|
||||
-- =============================================================
|
||||
|
||||
ieee8021STParametersTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF Ieee8021STParametersEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table that contains the per-port manageable parameters for
|
||||
traffic scheduling.
|
||||
|
||||
For a given Port, a row in the table exists.
|
||||
|
||||
All writable objects in this table must be
|
||||
persistent over power up restart/reboot."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParameters 1 }
|
||||
|
||||
ieee8021STParametersEntry OBJECT-TYPE
|
||||
SYNTAX Ieee8021STParametersEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A list of objects that contains the manageable parameters for
|
||||
traffic scheduling for a port."
|
||||
INDEX { ieee8021BridgeBaseComponentId,
|
||||
ieee8021BridgeBasePort
|
||||
}
|
||||
::= { ieee8021STParametersTable 1 }
|
||||
|
||||
Ieee8021STParametersEntry ::=
|
||||
SEQUENCE {
|
||||
ieee8021STGateEnabled
|
||||
TruthValue,
|
||||
ieee8021STAdminGateStates
|
||||
OCTET STRING,
|
||||
ieee8021STOperGateStates
|
||||
OCTET STRING,
|
||||
ieee8021STAdminControlListLength
|
||||
Unsigned32,
|
||||
ieee8021STOperControlListLength
|
||||
Unsigned32,
|
||||
ieee8021STAdminControlList
|
||||
OCTET STRING,
|
||||
ieee8021STOperControlList
|
||||
OCTET STRING,
|
||||
ieee8021STAdminCycleTimeNumerator
|
||||
Unsigned32,
|
||||
ieee8021STAdminCycleTimeDenominator
|
||||
Unsigned32,
|
||||
ieee8021STOperCycleTimeNumerator
|
||||
Unsigned32,
|
||||
ieee8021STOperCycleTimeDenominator
|
||||
Unsigned32,
|
||||
ieee8021STAdminCycleTimeExtension
|
||||
Unsigned32,
|
||||
ieee8021STOperCycleTimeExtension
|
||||
Unsigned32,
|
||||
ieee8021STAdminBaseTime
|
||||
IEEE8021STPTPtimeValue,
|
||||
ieee8021STOperBaseTime
|
||||
IEEE8021STPTPtimeValue,
|
||||
ieee8021STConfigChange
|
||||
TruthValue,
|
||||
ieee8021STConfigChangeTime
|
||||
IEEE8021STPTPtimeValue,
|
||||
ieee8021STTickGranularity
|
||||
Unsigned32,
|
||||
ieee8021STCurrentTime
|
||||
IEEE8021STPTPtimeValue,
|
||||
ieee8021STConfigPending
|
||||
TruthValue,
|
||||
ieee8021STConfigChangeError
|
||||
Counter64,
|
||||
ieee8021STSupportedListMax
|
||||
Unsigned32
|
||||
}
|
||||
|
||||
ieee8021STGateEnabled OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The GateEnabled parameter determines whether traffic scheduling
|
||||
is active (true) or inactive (false).
|
||||
|
||||
The value of this object MUST be retained across
|
||||
reinitializations of the management system."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
DEFVAL { false }
|
||||
::= { ieee8021STParametersEntry 1 }
|
||||
|
||||
ieee8021STAdminGateStates OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(1))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The administrative value of the GateStates parameter for the Port.
|
||||
The bits of the octet represent the gate states for the
|
||||
corresponding traffic classes; the MS bit corresponds to traffic class 7,
|
||||
the LS bit to traffic class 0. A bit value of 0 indicates closed; a
|
||||
bit value of 1 indicates open.
|
||||
|
||||
The value of this object MUST be retained across
|
||||
reinitializations of the management system."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 2 }
|
||||
|
||||
ieee8021STOperGateStates OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(1))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The operational value of the GateStates parameter for the Port.
|
||||
The bits of the octet represent the gate states for the
|
||||
corresponding traffic classes; the MS bit corresponds to traffic class 7,
|
||||
the LS bit to traffic class 0. A bit value of 0 indicates closed; a
|
||||
bit value of 1 indicates open."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 3 }
|
||||
|
||||
ieee8021STAdminControlListLength OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The administrative value of the ListMax parameter for the Port.
|
||||
The integer value indicates the number of entries (TLVs) in the
|
||||
AdminControlList.
|
||||
|
||||
The value of this object MUST be retained across
|
||||
reinitializations of the management system."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 4 }
|
||||
|
||||
ieee8021STOperControlListLength OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The operational value of the ListMax parameter for the Port.
|
||||
The integer value indicates the number of entries (TLVs) in the
|
||||
OperControlList."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 5 }
|
||||
|
||||
ieee8021STAdminControlList OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The administrative value of the ControlList parameter for the Port.
|
||||
The octet string value represents the contents of the control list as
|
||||
an ordered list of entries, each encoded as a TLV, as follows.
|
||||
The first octet of each TLV is interpreted as an
|
||||
unsigned integer representing a gate operation name:
|
||||
0: SetGateStates
|
||||
1: Set-And-Hold-MAC
|
||||
2: Set-And-Release-MAC
|
||||
3-255: Reserved for future gate operations
|
||||
|
||||
The second octet of the TLV is the length field,
|
||||
interpreted as an unsigned integer, indicating the number of
|
||||
octets of the value that follows the length. A length of
|
||||
zero indicates that there is no value
|
||||
(i.e., the gate operation has no parameters).
|
||||
|
||||
The third through (3 + length -1)th octets encode the
|
||||
parameters of the gate operation, in the order that they
|
||||
appear in the definition of the operation
|
||||
in Table 8-6. Two parameter types are currently defined:
|
||||
|
||||
- GateState:
|
||||
A GateState parameter is encoded in a single octet.
|
||||
The bits of the octet represent the gate states for the
|
||||
corresponding traffic classes; the MS bit corresponds
|
||||
to traffic class 7,
|
||||
the LS bit to traffic class 0. A bit value of 0 indicates
|
||||
closed; a bit value of 1 indicates open.
|
||||
|
||||
- TimeInterval:
|
||||
A TimeInterval is encoded in 4 octets as a 32-bit
|
||||
unsigned integer, representing a number of nanoseconds.
|
||||
The first octet encodes the most significant 8 bits of the
|
||||
integer, and the fourth octet encodes the least
|
||||
significant 8 bits.
|
||||
|
||||
The value of this object MUST be retained across
|
||||
reinitializations of the management system."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 6 }
|
||||
|
||||
ieee8021STOperControlList OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The operational value of the ListMax parameter for the Port.
|
||||
The octet string value represents the contents of the control list as
|
||||
an ordered list of TLVs, as follows.
|
||||
The first octet of each TLV is interpreted as a gate operation name:
|
||||
0: SetGateStates
|
||||
1: Set-And-Hold-MAC
|
||||
2: Set-And-Release-MAC
|
||||
3-255: Reserved for future gate operations
|
||||
|
||||
The second octet of the TLV is the length field,
|
||||
interpreted as an unsigned integer,
|
||||
indicating the number of octets of the value that follows
|
||||
the length. A length of zero indicates that there is no value
|
||||
(i.e., the gate operation has no parameters).
|
||||
|
||||
The third through (3 + length -1)th octets encode the
|
||||
parameters of the gate operation, in the order that they
|
||||
appear in the definition of the operation
|
||||
in Table 8-6. Two parameter types are currently defined:
|
||||
|
||||
- GateState:
|
||||
A GateState parameter is encoded in a single octet.
|
||||
The bits of the octet represent the gate states for the
|
||||
corresponding traffic classes; the MS bit corresponds to
|
||||
traffic class 7, the LS bit to traffic class 0.
|
||||
A bit value of 0 indicates closed; a
|
||||
bit value of 1 indicates open.
|
||||
|
||||
- TimeInterval:
|
||||
A TimeInterval is encoded in 4 octets as a 32-bit
|
||||
unsigned integer, representing
|
||||
a number of nanoseconds. The first octet encodes the
|
||||
most significant 8 bits of the integer, and the fourth
|
||||
octet encodes the least significant 8 bits."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 7 }
|
||||
|
||||
ieee8021STAdminCycleTimeNumerator OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The administrative value of the numerator of the CycleTime
|
||||
parameter for the Port.
|
||||
The numerator and denominator together represent the cycle time as
|
||||
a rational number of seconds.
|
||||
|
||||
The value of this object MUST be retained across
|
||||
reinitializations of the management system."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 8 }
|
||||
|
||||
ieee8021STAdminCycleTimeDenominator OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The administrative value of the denominator of the
|
||||
CycleTime parameter for the Port.
|
||||
The numerator and denominator together represent the cycle time as
|
||||
a rational number of seconds.
|
||||
|
||||
The value of this object MUST be retained across
|
||||
reinitializations of the management system."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 9 }
|
||||
|
||||
ieee8021STOperCycleTimeNumerator OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The operational value of the numerator of the
|
||||
CycleTime parameter for the Port.
|
||||
The numerator and denominator together represent the cycle
|
||||
time as a rational number of seconds."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 10 }
|
||||
|
||||
ieee8021STOperCycleTimeDenominator OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The operational value of the denominator of the
|
||||
CycleTime parameter for the Port.
|
||||
The numerator and denominator together represent the
|
||||
cycle time as a rational number of seconds."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 11 }
|
||||
|
||||
ieee8021STAdminCycleTimeExtension OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
UNITS "nanoseconds"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The administrative value of the CycleTimeExtension
|
||||
parameter for the Port.
|
||||
The value is an unsigned integer number of nanoseconds.
|
||||
|
||||
The value of this object MUST be retained across
|
||||
reinitializations of the management system."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 12 }
|
||||
|
||||
ieee8021STOperCycleTimeExtension OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
UNITS "nanoseconds"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The operational value of the CycleTimeExtension parameter for the Port.
|
||||
The value is an unsigned integer number of nanoseconds."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 13 }
|
||||
|
||||
ieee8021STAdminBaseTime OBJECT-TYPE
|
||||
SYNTAX IEEE8021STPTPtimeValue
|
||||
UNITS "PTP time"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The administrative value of the BaseTime parameter for the Port.
|
||||
The value is a representation of a PTPtime value,
|
||||
consisting of a 48-bit integer
|
||||
number of seconds and a 32-bit integer number of nanoseconds.
|
||||
|
||||
The value of this object MUST be retained across
|
||||
reinitializations of the management system."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 14 }
|
||||
|
||||
ieee8021STOperBaseTime OBJECT-TYPE
|
||||
SYNTAX IEEE8021STPTPtimeValue
|
||||
UNITS "PTP time"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The operationsl value of the BaseTime parameter for the Port.
|
||||
The value is a representation of a PTPtime value,
|
||||
consisting of a 48-bit integer
|
||||
number of seconds and a 32-bit integer number of nanoseconds."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 15 }
|
||||
|
||||
ieee8021STConfigChange OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The ConfigChange parameter signals the start of a
|
||||
configuration change
|
||||
when it is set to TRUE. This should only be done
|
||||
when the various administrative parameters
|
||||
are all set to appropriate values."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 16 }
|
||||
|
||||
ieee8021STConfigChangeTime OBJECT-TYPE
|
||||
SYNTAX IEEE8021STPTPtimeValue
|
||||
UNITS "PTP time"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The PTPtime at which the next config change is scheduled to occur.
|
||||
The value is a representation of a PTPtime value,
|
||||
consisting of a 48-bit integer
|
||||
number of seconds and a 32-bit integer number of nanoseconds.
|
||||
|
||||
The value of this object MUST be retained across
|
||||
reinitializations of the management system."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 17 }
|
||||
|
||||
ieee8021STTickGranularity OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The granularity of the cycle time clock, represented as an
|
||||
unsigned number of tenths of nanoseconds.
|
||||
|
||||
The value of this object MUST be retained across
|
||||
reinitializations of the management system."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 18 }
|
||||
|
||||
ieee8021STCurrentTime OBJECT-TYPE
|
||||
SYNTAX IEEE8021STPTPtimeValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current time, in PTPtime, as maintained by the local system.
|
||||
The value is a representation of a PTPtime value,
|
||||
consisting of a 48-bit integer
|
||||
number of seconds and a 32-bit integer number of nanoseconds."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 19 }
|
||||
|
||||
ieee8021STConfigPending OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of the ConfigPending state machine variable.
|
||||
The value is TRUE if a configuration change is in progress
|
||||
but has not yet completed."
|
||||
REFERENCE "8.6.8.4, 8.6.9.4, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 20 }
|
||||
|
||||
ieee8021STConfigChangeError OBJECT-TYPE
|
||||
SYNTAX Counter64
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A counter of the number of times that a re-configuration
|
||||
of the traffic schedule has been requested with the old
|
||||
schedule still running and the requested base time was
|
||||
in the past."
|
||||
REFERENCE "8.6.8.4, 8.6.9.3, 8.6.9.1.1, 12.29.1"
|
||||
::= { ieee8021STParametersEntry 21 }
|
||||
|
||||
ieee8021STSupportedListMax OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The maximum value supported by this Port of the
|
||||
AdminControlListLength and OperControlListLength
|
||||
parameters."
|
||||
REFERENCE "12.29.1.5"
|
||||
::= { ieee8021STParametersEntry 22 }
|
||||
|
||||
|
||||
-- =============================================================
|
||||
-- IEEE8021 FQTSS MIB - Conformance Information
|
||||
-- =============================================================
|
||||
|
||||
ieee8021STCompliances
|
||||
OBJECT IDENTIFIER ::= { ieee8021STConformance 1 }
|
||||
ieee8021STGroups
|
||||
OBJECT IDENTIFIER ::= { ieee8021STConformance 2 }
|
||||
|
||||
-- =============================================================
|
||||
-- units of conformance
|
||||
-- =============================================================
|
||||
|
||||
-- =============================================================
|
||||
-- the ieee8021STObjectsGroup group
|
||||
-- =============================================================
|
||||
|
||||
ieee8021STObjectsGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
ieee8021STMaxSDU,
|
||||
ieee8021TransmissionOverrun,
|
||||
ieee8021STGateEnabled,
|
||||
ieee8021STAdminGateStates,
|
||||
ieee8021STOperGateStates,
|
||||
ieee8021STAdminControlListLength,
|
||||
ieee8021STOperControlListLength,
|
||||
ieee8021STAdminControlList,
|
||||
ieee8021STOperControlList,
|
||||
ieee8021STAdminCycleTimeNumerator,
|
||||
ieee8021STAdminCycleTimeDenominator,
|
||||
ieee8021STOperCycleTimeNumerator,
|
||||
ieee8021STOperCycleTimeDenominator,
|
||||
ieee8021STAdminCycleTimeExtension,
|
||||
ieee8021STOperCycleTimeExtension,
|
||||
ieee8021STAdminBaseTime,
|
||||
ieee8021STOperBaseTime,
|
||||
ieee8021STConfigChange,
|
||||
ieee8021STConfigChangeTime,
|
||||
ieee8021STTickGranularity,
|
||||
ieee8021STCurrentTime,
|
||||
ieee8021STConfigPending,
|
||||
ieee8021STConfigChangeError,
|
||||
ieee8021STSupportedListMax
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Objects that allow management of scheduled traffic."
|
||||
::= { ieee8021STGroups 1 }
|
||||
|
||||
|
||||
-- =============================================================
|
||||
-- compliance statements
|
||||
-- =============================================================
|
||||
|
||||
ieee8021STCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for devices supporting
|
||||
scheduled traffic.
|
||||
|
||||
Support of the objects defined in this MIB module
|
||||
also requires support of the IEEE8021-BRIDGE-MIB; the
|
||||
provisions of 17.3.2 apply to implementations claiming
|
||||
support of this MIB. "
|
||||
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS {
|
||||
ieee8021STObjectsGroup
|
||||
}
|
||||
|
||||
::= { ieee8021STCompliances 1 }
|
||||
|
||||
END
|
Reference in New Issue
Block a user