initial commit; version 22.5.12042
This commit is contained in:
689
mibs/rfc/GMPLS-LABEL-STD-MIB
Normal file
689
mibs/rfc/GMPLS-LABEL-STD-MIB
Normal file
@ -0,0 +1,689 @@
|
||||
GMPLS-LABEL-STD-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Integer32
|
||||
FROM SNMPv2-SMI -- RFC 2578
|
||||
MODULE-COMPLIANCE, OBJECT-GROUP
|
||||
FROM SNMPv2-CONF -- RFC 2580
|
||||
RowStatus, StorageType
|
||||
FROM SNMPv2-TC -- RFC 2579
|
||||
InterfaceIndexOrZero
|
||||
FROM IF-MIB -- RFC 2863
|
||||
IndexIntegerNextFree
|
||||
FROM DIFFSERV-MIB -- RFC 3289
|
||||
MplsLabel, mplsStdMIB
|
||||
FROM MPLS-TC-STD-MIB -- RFC 3811
|
||||
GmplsLabelTypeTC, GmplsFreeformLabelTC
|
||||
FROM GMPLS-TC-STD-MIB -- RFC 4801
|
||||
;
|
||||
|
||||
gmplsLabelStdMIB MODULE-IDENTITY
|
||||
LAST-UPDATED
|
||||
"200702270000Z" -- 27 February 2007 00:00:00 GMT
|
||||
ORGANIZATION
|
||||
"IETF Common Control and Measurement Plane (CCAMP) Working Group"
|
||||
CONTACT-INFO
|
||||
" Thomas D. Nadeau
|
||||
Cisco Systems, Inc.
|
||||
Email: tnadeau@cisco.com
|
||||
|
||||
Adrian Farrel
|
||||
Old Dog Consulting
|
||||
Email: adrian@olddog.co.uk
|
||||
|
||||
Comments about this document should be emailed directly to the
|
||||
CCAMP working group mailing list at ccamp@ops.ietf.org."
|
||||
DESCRIPTION
|
||||
"Copyright (C) The IETF Trust (2007). This version of
|
||||
this MIB module is part of RFC 4803; see the RFC itself for
|
||||
full legal notices.
|
||||
|
||||
This MIB module contains managed object definitions for labels
|
||||
within GMPLS systems as defined in
|
||||
Generalized Multi-Protocol Label Switching (GMPLS) Signaling
|
||||
Functional Description, Berger, L. (Editor), RFC 3471,
|
||||
January 2003."
|
||||
REVISION
|
||||
"200702270000Z" -- 27 February 2007 00:00:00 GMT
|
||||
DESCRIPTION
|
||||
"Initial version issued as part of RFC 4803."
|
||||
::= { mplsStdMIB 16 }
|
||||
|
||||
-- no notifications are currently defined.
|
||||
|
||||
gmplsLabelObjects OBJECT IDENTIFIER ::= { gmplsLabelStdMIB 1 }
|
||||
gmplsLabelConformance OBJECT IDENTIFIER ::= { gmplsLabelStdMIB 2 }
|
||||
|
||||
gmplsLabelIndexNext OBJECT-TYPE
|
||||
SYNTAX IndexIntegerNextFree
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object contains an unused value for gmplsLabelIndex,
|
||||
or a zero to indicate that no unused value exists or is
|
||||
available.
|
||||
|
||||
A management application wishing to create a row in the
|
||||
gmplsLabelTable may read this object and then attempt to
|
||||
create a row in the table. If row creation fails (because
|
||||
another application has already created a row with the
|
||||
supplied index), the management application should read this
|
||||
object again to get a new index value.
|
||||
|
||||
When a row is created in the gmplsLabelTable with the
|
||||
gmplsLabelIndex value held by this object, an implementation
|
||||
MUST change the value in this object."
|
||||
::= { gmplsLabelObjects 1 }
|
||||
|
||||
gmplsLabelTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF GmplsLabelEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Table of GMPLS Labels. This table allows the representation
|
||||
of the more complex label forms required for GMPLS that cannot
|
||||
be held within the TEXTUAL-CONVENTION MplsLabel; that is, labels
|
||||
that cannot be encoded within 32 bits. It is, nevertheless, also
|
||||
capable of holding 32-bit labels or regular MPLS Labels if
|
||||
desired.
|
||||
|
||||
Each entry in this table represents an individual GMPLS Label
|
||||
value. The representation of Labels in tables in other MIB
|
||||
modules may be achieved by a referrence to an entry in this
|
||||
table by means of a row pointer into this table. The indexing
|
||||
of this table provides for arbitrary indexing and also for
|
||||
concatenation of labels.
|
||||
|
||||
For an example of label concatenation, see RFC 3945, section 7.1.
|
||||
In essence, a GMPLS Label may be composite in order to identify
|
||||
a set of resources in the data plane. Practical examples are
|
||||
timeslots and wavelength sets (which are not contiguous like
|
||||
wavebands).
|
||||
|
||||
The indexing mechanism allows multiple entries in this table to
|
||||
be seen as a sequence of labels that should be concatenated.
|
||||
Ordering is potentially very sensitive for concatenation."
|
||||
REFERENCE
|
||||
"1. Generalized Multiprotocol Label Switching (GMPLS)
|
||||
Architecture, RFC 3945, section 7.1."
|
||||
::= { gmplsLabelObjects 2 }
|
||||
|
||||
gmplsLabelEntry OBJECT-TYPE
|
||||
SYNTAX GmplsLabelEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in this table represents a single label value. There
|
||||
are three indexes into the table.
|
||||
|
||||
- The interface index may be helpful to distinguish which
|
||||
labels are in use on which interfaces or to handle cases
|
||||
where there are a very large number of labels in use in the
|
||||
system. When label representation is desired to apply to the
|
||||
whole system or when it is not important to distinguish
|
||||
labels by their interfaces, this index MAY be set to zero.
|
||||
|
||||
- The label index provides a way of identifying the label.
|
||||
|
||||
- The label sub-index is only used for concatenated labels. It
|
||||
identifies each component label. When non-concatenated labels
|
||||
are used, this index SHOULD be set to zero.
|
||||
|
||||
A storage type object is supplied to control the storage type
|
||||
for each entry, but implementations should note that the storage
|
||||
type of conceptual rows in other tables that include row
|
||||
pointers to an entry in this table SHOULD dictate the storage
|
||||
type of the rows in this table where the row in the other table
|
||||
is more persistent."
|
||||
INDEX {
|
||||
gmplsLabelInterface,
|
||||
gmplsLabelIndex,
|
||||
gmplsLabelSubindex }
|
||||
::= { gmplsLabelTable 1 }
|
||||
|
||||
GmplsLabelEntry ::= SEQUENCE {
|
||||
gmplsLabelInterface InterfaceIndexOrZero,
|
||||
gmplsLabelIndex Unsigned32,
|
||||
gmplsLabelSubindex Unsigned32,
|
||||
gmplsLabelType GmplsLabelTypeTC,
|
||||
gmplsLabelMplsLabel MplsLabel,
|
||||
gmplsLabelPortWavelength Unsigned32,
|
||||
gmplsLabelFreeform GmplsFreeformLabelTC,
|
||||
gmplsLabelSonetSdhSignalIndex Integer32,
|
||||
gmplsLabelSdhVc Integer32,
|
||||
gmplsLabelSdhVcBranch Integer32,
|
||||
gmplsLabelSonetSdhBranch Integer32,
|
||||
gmplsLabelSonetSdhGroupBranch Integer32,
|
||||
gmplsLabelWavebandId Unsigned32,
|
||||
gmplsLabelWavebandStart Unsigned32,
|
||||
gmplsLabelWavebandEnd Unsigned32,
|
||||
gmplsLabelStorageType StorageType,
|
||||
gmplsLabelRowStatus RowStatus
|
||||
}
|
||||
|
||||
gmplsLabelInterface OBJECT-TYPE
|
||||
SYNTAX InterfaceIndexOrZero
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The interface on which this label is used. If this object is set
|
||||
to zero, the label MUST have applicability across the
|
||||
whole system and not be limited to a single interface."
|
||||
::= { gmplsLabelEntry 1 }
|
||||
|
||||
gmplsLabelIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..4294967295)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An arbitrary index into the table to identify a label.
|
||||
|
||||
Note that implementations that are representing 32-bit labels
|
||||
within this table MAY choose to align this index with the value
|
||||
of the label, and this may result in the use of the value zero
|
||||
since it represents a valid label value. Such implementation
|
||||
should be aware of the implications of sparsely populated
|
||||
|
||||
tables.
|
||||
|
||||
A management application may read the gmplsLabelIndexNext
|
||||
object to find a suitable value for this object."
|
||||
::= { gmplsLabelEntry 2 }
|
||||
|
||||
gmplsLabelSubindex OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..4294967295)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"In conjunction with gmplsLabelInterface and gmplsLabelIndex,
|
||||
this object uniquely identifies this row. This sub-index allows
|
||||
a single GMPLS Label to be defined as a concatenation of labels.
|
||||
This is particularly useful in TDM.
|
||||
|
||||
The ordering of sub-labels is strict with the sub-label with
|
||||
the lowest gmplsLabelSubindex appearing first. Note that all
|
||||
sub-labels of a single GMPLS Label must share the same
|
||||
gmplsLabelInterface and gmplsLabelIndex values. For labels that
|
||||
are not composed of concatenated sub-labels, this value SHOULD
|
||||
be set to zero."
|
||||
::= { gmplsLabelEntry 3 }
|
||||
|
||||
gmplsLabelType OBJECT-TYPE
|
||||
SYNTAX GmplsLabelTypeTC
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identifies the type of this label. Note that this object does
|
||||
not determine whether MPLS or GMPLS signaling is in use: a value
|
||||
of gmplsMplsLabel(1) denotes that an MPLS Packet Label is
|
||||
present in the gmplsLabelMplsLabel object and encoded using the
|
||||
MplsLabel TEXTUAL-CONVENTION (may be a 20-bit MPLS Label, a 10-
|
||||
or 23-bit Frame Relay Label, or an Asynchronous Transfer Mode
|
||||
(ATM) Label), but does not describe whether this is signaled
|
||||
using MPLS or GMPLS.
|
||||
|
||||
The value of this object helps determine which of the following
|
||||
objects are valid. This object cannot be modified if
|
||||
gmplsLabelRowStatus is active(1)."
|
||||
REFERENCE
|
||||
"1. Generalized Multi-Protocol Label Switching (GMPLS) Signaling
|
||||
Functional Description, RFC 3471, section 3."
|
||||
::= { gmplsLabelEntry 4 }
|
||||
|
||||
gmplsLabelMplsLabel OBJECT-TYPE
|
||||
SYNTAX MplsLabel
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of an MPLS Label (that is a Packet Label) if this
|
||||
table is used to store it. This may be used in MPLS systems even
|
||||
though the label values can be adequately stored in the MPLS MIB
|
||||
modules (MPLS-LSR-STD-MIB and MPLS-TE-STD-MIB). Furthermore, in
|
||||
mixed MPLS and GMPLS systems, it may be advantageous to store all
|
||||
labels in a single label table. Lastly, in GMPLS systems where
|
||||
Packet Labels are used (that is in systems that use GMPLS
|
||||
signaling and GMPLS Labels for packet switching), it may be
|
||||
desirable to use this table.
|
||||
|
||||
This object is only valid if gmplsLabelType is set
|
||||
to gmplsMplsLabel(1). This object cannot be modified if
|
||||
gmplsLabelRowStatus is active(1)."
|
||||
REFERENCE
|
||||
"1. MPLS Label Stack Encoding, RFC 3032."
|
||||
DEFVAL { 0 }
|
||||
::= { gmplsLabelEntry 5 }
|
||||
|
||||
gmplsLabelPortWavelength OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of a Port or Wavelength Label when carried as a
|
||||
Generalized Label. Only valid if gmplsLabelType is set to
|
||||
gmplsPortWavelengthLabel(2). This object cannot be modified if
|
||||
gmplsLabelRowStatus is active(1)."
|
||||
REFERENCE
|
||||
"1. Generalized Multi-Protocol Label Switching (GMPLS) Signaling
|
||||
Functional Description, RFC 3471, section 3.2.1.1."
|
||||
DEFVAL { 0 }
|
||||
::= { gmplsLabelEntry 6 }
|
||||
|
||||
gmplsLabelFreeform OBJECT-TYPE
|
||||
SYNTAX GmplsFreeformLabelTC
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of a Freeform Generalized Label that does not conform
|
||||
to one of the standardized label encodings or that an
|
||||
implementation chooses to represent as an octet string without
|
||||
further decoding. Only valid if gmplsLabelType is set to
|
||||
gmplsFreeformLabel(3). This object cannot be modified
|
||||
if gmplsLabelRowStatus is active(1)."
|
||||
REFERENCE
|
||||
"1. Generalized Multi-Protocol Label Switching (GMPLS) Signaling
|
||||
Functional Description, RFC 3471, section 3.2."
|
||||
DEFVAL { '00'h }
|
||||
::= { gmplsLabelEntry 7 }
|
||||
|
||||
gmplsLabelSonetSdhSignalIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..4095)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Signal Index value (S) of a SONET or SDH Generalized Label.
|
||||
Zero indicates that this field is non-significant. Only valid if
|
||||
gmplsLabelType is set to gmplsSonetLabel(4) or gmplsSdhLabel(5).
|
||||
This object cannot be modified if gmplsLabelRowStatus is
|
||||
active(1)."
|
||||
REFERENCE
|
||||
"1. Generalized Multi-Protocol Label Switching (GMPLS) Extensions
|
||||
for Synchronous Optical Network (SONET) and Synchronous
|
||||
Digital Hierarchy (SDH) Control, RFC 4606, section 3."
|
||||
DEFVAL { 0 }
|
||||
::= { gmplsLabelEntry 8 }
|
||||
|
||||
gmplsLabelSdhVc OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..15)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The VC Indicator (U) of an SDH Generalized Label. Zero indicates
|
||||
that this field is non-significant. Only valid if gmplsLabelType
|
||||
is set to gmplsSdhLabel(5). This object cannot be modified if
|
||||
gmplsLabelRowStatus is active(1)."
|
||||
REFERENCE
|
||||
"1. Generalized Multi-Protocol Label Switching (GMPLS) Extensions
|
||||
for Synchronous Optical Network (SONET) and Synchronous
|
||||
Digital Hierarchy (SDH) Control, RFC 4606, section 3."
|
||||
DEFVAL { 0 }
|
||||
::= { gmplsLabelEntry 9 }
|
||||
|
||||
gmplsLabelSdhVcBranch OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..15)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The VC Branch Indicator (K) of an SDH Generalized Label. Zero
|
||||
indicates that this field is non-significant. Only valid if
|
||||
gmplsLabelType is set to gmplsSdhLabel(5). This
|
||||
object cannot be modified if gmplsLabelRowStatus is active(1)."
|
||||
REFERENCE
|
||||
"1. Generalized Multi-Protocol Label Switching (GMPLS) Extensions
|
||||
for Synchronous Optical Network (SONET) and Synchronous
|
||||
Digital Hierarchy (SDH) Control, RFC 4606, section 3."
|
||||
DEFVAL { 0 }
|
||||
::= { gmplsLabelEntry 10 }
|
||||
|
||||
gmplsLabelSonetSdhBranch OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..15)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Branch Indicator (L) of a SONET or SDH Generalized Label.
|
||||
Zero indicates that this field is non-significant. Only valid
|
||||
gmplsLabelType is set to gmplsSonetLabel(4) or
|
||||
gmplsSdhLabel(5). This object cannot be modified if
|
||||
gmplsLabelRowStatus is active(1)."
|
||||
REFERENCE
|
||||
"1. Generalized Multi-Protocol Label Switching (GMPLS) Extensions
|
||||
for Synchronous Optical Network (SONET) and Synchronous
|
||||
Digital Hierarchy (SDH) Control, RFC 4606, section 3."
|
||||
DEFVAL { 0 }
|
||||
::= { gmplsLabelEntry 11 }
|
||||
|
||||
gmplsLabelSonetSdhGroupBranch OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..15)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Group Branch Indicator (M) of a SONET or SDH Generalized
|
||||
Label. Zero indicates that this field is non-significant.
|
||||
Only valid if gmplsLabelType is set to gmplsSonetLabel(4) or
|
||||
gmplsSdhLabel(5). This object cannot be modified if
|
||||
gmplsLabelRowStatus is active(1)."
|
||||
REFERENCE
|
||||
"1. Generalized Multi-Protocol Label Switching (GMPLS) Extensions
|
||||
for Synchronous Optical Network (SONET) and Synchronous
|
||||
Digital Hierarchy (SDH) Control, RFC 4606, section 3."
|
||||
DEFVAL { 0 }
|
||||
::= { gmplsLabelEntry 12 }
|
||||
|
||||
gmplsLabelWavebandId OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The waveband identifier component of a Waveband Label. Only
|
||||
valid if gmplsLabelType is set to gmplsWavebandLabel(6). This
|
||||
object cannot be modified if gmplsLabelRowStatus is active(1)."
|
||||
REFERENCE
|
||||
"1. Generalized Multi-Protocol Label Switching (GMPLS) Signaling
|
||||
Functional Description, RFC 3471, section 3.3."
|
||||
DEFVAL { 0 }
|
||||
::= { gmplsLabelEntry 13 }
|
||||
|
||||
gmplsLabelWavebandStart OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The starting label component of a Waveband Label. Only valid if
|
||||
gmplsLabelType is set to gmplsWavebandLabel(6). This object
|
||||
cannot be modified if gmplsLabelRowStatus is active(1)."
|
||||
REFERENCE
|
||||
"1. Generalized Multi-Protocol Label Switching (GMPLS) Signaling
|
||||
Functional Description, RFC 3471, section 3.3."
|
||||
DEFVAL { 0 }
|
||||
::= { gmplsLabelEntry 14 }
|
||||
|
||||
gmplsLabelWavebandEnd OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The end label component of a Waveband Label. Only valid if
|
||||
gmplsLabelType is set to gmplsWavebandLabel(6). This object
|
||||
cannot be modified if gmplsLabelRowStatus is active(1)."
|
||||
REFERENCE
|
||||
"1. Generalized Multi-Protocol Label Switching (GMPLS) Signaling
|
||||
Functional Description, RFC 3471, section 3.3."
|
||||
DEFVAL { 0 }
|
||||
::= { gmplsLabelEntry 15 }
|
||||
|
||||
gmplsLabelStorageType OBJECT-TYPE
|
||||
SYNTAX StorageType
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the storage type for this row. The
|
||||
agent MUST ensure that this object's value remains consistent
|
||||
with the storage type of any rows in other tables that contain
|
||||
pointers to this row. In particular, the storage type of this
|
||||
row must be at least as permanent as that of any row that points
|
||||
to it.
|
||||
Conceptual rows having the value 'permanent' need not
|
||||
allow write-access to any columnar objects in the row."
|
||||
REFERENCE
|
||||
"1. Textual Conventions for SMIv2, STD 58, RFC 2579, section 2."
|
||||
DEFVAL { volatile }
|
||||
::= { gmplsLabelEntry 16 }
|
||||
|
||||
gmplsLabelRowStatus OBJECT-TYPE
|
||||
SYNTAX RowStatus
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable is used to create, modify, and/or delete a row in
|
||||
this table. When a row in this table has a row in the active(1)
|
||||
state, no objects in this row can be modified except the
|
||||
gmplsLabelRowStatus and gmplsLabelStorageType.
|
||||
|
||||
The gmplsLabelType object does not have a default and must be
|
||||
set before a row can become active. The corresponding label
|
||||
objects (dependent on the value of gmplsLabelType) should also
|
||||
be set unless they happen to need to use the specified default
|
||||
values as follows:
|
||||
|
||||
gmplsLabelType setting objects to be set
|
||||
--------------------------------------------------------------
|
||||
gmplsMplsLabel(1) gmplsLabelMplsLabel
|
||||
|
||||
gmplsPortWavelengthLabel(2) gmplsLabelPortWavelength
|
||||
|
||||
gmplsFreeformLabel(3) gmplsLabelFreeform
|
||||
|
||||
gmplsSonetLabel(4) gmplsLabelSonetSdhSignalIndex
|
||||
gmplsLabelSdhVc
|
||||
gmplsLabelSdhVcBranch
|
||||
gmplsLabelSonetSdhBranch
|
||||
gmplsLabelSonetSdhGroupBranch
|
||||
|
||||
gmplsSdhLabel(5) gmplsLabelSonetSdhSignalIndex
|
||||
gmplsLabelSdhVc
|
||||
gmplsLabelSdhVcBranch
|
||||
gmplsLabelSonetSdhBranch
|
||||
gmplsLabelSonetSdhGroupBranch
|
||||
|
||||
gmplsWavebandLabel(6) gmplsLabelWavebandId
|
||||
gmplsLabelWavebandStart
|
||||
gmplsLabelWavebandEnd"
|
||||
::= { gmplsLabelEntry 17 }
|
||||
|
||||
gmplsLabelGroups
|
||||
OBJECT IDENTIFIER ::= { gmplsLabelConformance 1 }
|
||||
|
||||
gmplsLabelCompliances
|
||||
OBJECT IDENTIFIER ::= { gmplsLabelConformance 2 }
|
||||
|
||||
gmplsLabelModuleReadOnlyCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Compliance requirement for implementations that only provide
|
||||
read-only support for GMPLS-LABEL-STD-MIB. Such devices can then
|
||||
be monitored but cannot be configured using this MIB module."
|
||||
|
||||
MODULE -- this module
|
||||
|
||||
-- The mandatory groups have to be implemented by LSRs claiming
|
||||
-- support for this MIB module. This MIB module is, however, not
|
||||
-- mandatory for a working implementation of a GMPLS LSR with full
|
||||
-- MIB support if the GMPLS Labels in use can be represented within
|
||||
-- a 32-bit quantity.
|
||||
|
||||
MANDATORY-GROUPS {
|
||||
gmplsLabelTableGroup
|
||||
}
|
||||
|
||||
GROUP gmplsLabelPacketGroup
|
||||
DESCRIPTION
|
||||
"This group extends gmplsLabelTableGroup for implementations that
|
||||
support Packet Labels. It is optional for implementations that
|
||||
do not support Packet Labels."
|
||||
|
||||
GROUP gmplsLabelPortWavelengthGroup
|
||||
DESCRIPTION
|
||||
"This group extends gmplsLabelTableGroup for implementations that
|
||||
support Port and Wavelength Labels. It is optional for
|
||||
implementations that do not support Wavelength Labels."
|
||||
|
||||
GROUP gmplsLabelFreeformGroup
|
||||
DESCRIPTION
|
||||
"This group extends gmplsLabelTableGroup for implementations that
|
||||
support Freeform Labels. It is optional for implementations that
|
||||
do not support Freeform Labels."
|
||||
|
||||
GROUP gmplsLabelSonetSdhGroup
|
||||
DESCRIPTION
|
||||
"This group extends gmplsLabelTableGroup for implementations that
|
||||
support SONET or SDH Labels. It is optional for implementations
|
||||
that do not support SONET or SDH Labels."
|
||||
|
||||
GROUP gmplsLabelWavebandGroup
|
||||
DESCRIPTION
|
||||
"This group extends gmplsLabelTableGroup for implementations that
|
||||
support Waveband Labels. It is optional for implementations that
|
||||
do not support Waveband Labels."
|
||||
OBJECT gmplsLabelType
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT gmplsLabelMplsLabel
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT gmplsLabelPortWavelength
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT gmplsLabelFreeform
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT gmplsLabelSonetSdhSignalIndex
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT gmplsLabelSdhVc
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT gmplsLabelSdhVcBranch
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT gmplsLabelSonetSdhBranch
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT gmplsLabelSonetSdhGroupBranch
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT gmplsLabelWavebandId
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
OBJECT gmplsLabelWavebandStart
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT gmplsLabelWavebandEnd
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT gmplsLabelStorageType
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT gmplsLabelRowStatus
|
||||
SYNTAX RowStatus { active(1) }
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required, and active(1) is
|
||||
the only status that needs to be supported."
|
||||
::= { gmplsLabelCompliances 1 }
|
||||
|
||||
gmplsLabelModuleFullCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Compliance statement for agents that support the complete
|
||||
GMPLS-LABEL-STD-MIB module.
|
||||
|
||||
The mandatory groups have to be implemented by GMPLS LSRs
|
||||
claiming support for this MIB module. This MIB module is,
|
||||
however, not mandatory for a working implementation of a GMPLS
|
||||
LSR with full MIB support if the GMPLS Labels in use can be
|
||||
represented within a 32-bit quantity."
|
||||
|
||||
MODULE -- this module
|
||||
|
||||
MANDATORY-GROUPS {
|
||||
gmplsLabelTableGroup
|
||||
}
|
||||
::= { gmplsLabelCompliances 2 }
|
||||
|
||||
gmplsLabelTableGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
gmplsLabelIndexNext,
|
||||
gmplsLabelType,
|
||||
gmplsLabelStorageType,
|
||||
gmplsLabelRowStatus
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Necessary, but not sufficient, set of objects to implement label
|
||||
table support. In addition, depending on the type of labels
|
||||
supported, the following other groups defined below are
|
||||
mandatory:
|
||||
|
||||
gmplsLabelWavebandGroup and/or
|
||||
gmplsLabelPacketGroup and/or
|
||||
gmplsLabelPortWavelengthGroup and/or
|
||||
gmplsLabelFreeformGroup and/or
|
||||
gmplsLabelSonetSdhGroup."
|
||||
::= { gmplsLabelGroups 1 }
|
||||
|
||||
gmplsLabelPacketGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
gmplsLabelMplsLabel
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Object needed to implement Packet (MPLS) Labels."
|
||||
::= { gmplsLabelGroups 2 }
|
||||
|
||||
gmplsLabelPortWavelengthGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
gmplsLabelPortWavelength
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Object needed to implement Port and Wavelength Labels."
|
||||
::= { gmplsLabelGroups 3 }
|
||||
|
||||
gmplsLabelFreeformGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
gmplsLabelFreeform
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Object needed to implement Freeform Labels."
|
||||
::= { gmplsLabelGroups 4 }
|
||||
|
||||
gmplsLabelSonetSdhGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
gmplsLabelSonetSdhSignalIndex,
|
||||
gmplsLabelSdhVc,
|
||||
gmplsLabelSdhVcBranch,
|
||||
gmplsLabelSonetSdhBranch,
|
||||
gmplsLabelSonetSdhGroupBranch
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Objects needed to implement SONET and SDH Labels."
|
||||
::= { gmplsLabelGroups 5 }
|
||||
|
||||
gmplsLabelWavebandGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
gmplsLabelWavebandId,
|
||||
gmplsLabelWavebandStart,
|
||||
gmplsLabelWavebandEnd
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Objects needed to implement Waveband Labels."
|
||||
::= { gmplsLabelGroups 6 }
|
||||
|
||||
END
|