mibs/packetflux/PACKETFLUX-SITEMONITOR
Normal file
75
mibs/packetflux/PACKETFLUX-SITEMONITOR
Normal file
@ -0,0 +1,75 @@
|
||||
PACKETFLUX-SITEMONITOR DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, Integer32, OBJECT-TYPE,
|
||||
Gauge32, TimeTicks
|
||||
FROM SNMPv2-SMI
|
||||
packetfluxMgmt
|
||||
FROM PACKETFLUX-SMI
|
||||
OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
TruthValue
|
||||
FROM SNMPv2-TC;
|
||||
|
||||
sitemonitor OBJECT IDENTIFIER ::= { packetfluxMgmt 1 }
|
||||
|
||||
analogInputEntry OBJECT-TYPE
|
||||
SYNTAX analogInputEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enclosure entry."
|
||||
INDEX { analogInputId }
|
||||
::= { sitemonitor 27 }
|
||||
|
||||
analogInputId OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The id of the analog input."
|
||||
::= { analogInputEntry 1 }
|
||||
|
||||
analogInputDescr OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is the description of this Analog I/O. It can be read and written. The description is limited to 16 characters. We recommend either leaving it as is, or setting it to a better description of what is connected to this I/O point."
|
||||
::= { analogInputEntry 2 }
|
||||
|
||||
analogInputSlot OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is the Slot (Module) number for this Analog I/O. It corresponds to the Slot number in the Expansion Module table. 0 is the base unit, 1 is the first Expansion unit, and so on. It should be noted that the slot number will not necessarily correspond to the physical arrangement of expansion modules."
|
||||
::= { analogInputEntry 3 }
|
||||
|
||||
analogInputPosition OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is the Position Number of this Analog I/O. It will be the same for all identical modules. For instance, position 0 of an analog output module will always correspond to the first analog output. The relation between position and the exact I/O is documented in each expansion module's documentation."
|
||||
::= { analogInputEntry 4 }
|
||||
|
||||
analogInputValue OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This read-write value contains the actual status of the Analog I/O. When reading this value, it will typically correspond to the current status of the Analog I/O. For outputs, writing a value to this OID will cause the output to change to match that value. For inputs, writing to this value will have no effect. It should be noted that many Analog I/O modules will require additional math before the value is usable. For some modules, the value is in tenths or hundredths of the expected unit (for instance voltage might be read as 240 or 2400 for 24 volts)"
|
||||
::= { analogInputEntry 5 }
|
||||
|
||||
analogInputPowerOnValue OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This read-write value contains the status which the Analog Output is set to upon power on. For instance, if you write a value of '100' to this OID, upon power on, the corresponding output will be set to '100'."
|
||||
::= { analogInputEntry 6 }
|
||||
|
||||
|
||||
|
||||
END
|
34
mibs/packetflux/PACKETFLUX-SMI
Normal file
34
mibs/packetflux/PACKETFLUX-SMI
Normal file
@ -0,0 +1,34 @@
|
||||
PACKETFLUX-SMI DEFINITIONS ::= BEGIN
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, enterprises, OBJECT-IDENTITY
|
||||
FROM SNMPv2-SMI;
|
||||
|
||||
packetflux MODULE-IDENTITY
|
||||
LAST-UPDATED "201306041631Z"
|
||||
ORGANIZATION "PacketFlux Technologies"
|
||||
CONTACT-INFO "custsvc@packetflux.com
|
||||
http://www.packetflux.com"
|
||||
DESCRIPTION "SMI MIB for PacketFlux Technologies"
|
||||
|
||||
REVISION "201306041631Z"
|
||||
DESCRIPTION "initial version of this module"
|
||||
REVISION "201306042158Z"
|
||||
DESCRIPTION "Correct MIB ID"
|
||||
::= { enterprises 32050 }
|
||||
|
||||
|
||||
packetfluxProducts OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION "packetfluxProducts is the root OBJECT IDENTIFIER
|
||||
for products released by packetflux technologies."
|
||||
::= { packetflux 1 }
|
||||
|
||||
packetfluxMgmt OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION "This is the main subtree for all packetflux product
|
||||
management mibs."
|
||||
::= { packetflux 2 }
|
||||
|
||||
|
||||
END
|
||||
|
643
mibs/packetflux/PACKETFLUX-STANDBYPOWER
Normal file
643
mibs/packetflux/PACKETFLUX-STANDBYPOWER
Normal file
@ -0,0 +1,643 @@
|
||||
PACKETFLUX-STANDBYPOWER DEFINITIONS ::= BEGIN
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, Integer32, OBJECT-TYPE,
|
||||
Gauge32, TimeTicks
|
||||
FROM SNMPv2-SMI
|
||||
packetfluxMgmt
|
||||
FROM PACKETFLUX-SMI
|
||||
OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
TruthValue
|
||||
FROM SNMPv2-TC;
|
||||
|
||||
standbypower MODULE-IDENTITY
|
||||
LAST-UPDATED "201306041649Z"
|
||||
ORGANIZATION "PacketFlux Technologies"
|
||||
CONTACT-INFO "custsvc@packetflux.com
|
||||
http://www.packetflux.com"
|
||||
DESCRIPTION "MIB for the PacketFlux Standby Power Controller"
|
||||
|
||||
REVISION "201306041649Z"
|
||||
DESCRIPTION "initial version of this module"
|
||||
::= { packetfluxMgmt 2 }
|
||||
|
||||
|
||||
powercontrollerstate OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
onprimarypower( 1 ),
|
||||
startingstandby( 2 ),
|
||||
transferringtostandby( 3 ),
|
||||
onstandbypower( 4 ),
|
||||
transferringtoprimary( 5 )
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The status of the standby power controller."
|
||||
::= { standbypower 1 }
|
||||
|
||||
transferswitchstate OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
primary( 1 ),
|
||||
transfertostandby1( 2 ),
|
||||
transfertostandby2( 3 ),
|
||||
transfertostandby3( 4 ),
|
||||
standby( 5 ),
|
||||
transfertoprimary1( 6 ),
|
||||
transfertoprimary2( 7 ),
|
||||
transfertoprimary3( 8 )
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The current state in the transfer sequence."
|
||||
::= { standbypower 2 }
|
||||
|
||||
standbypowerstate OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
stopped( 1 ),
|
||||
prepare1( 2 ),
|
||||
prepare2( 3 ),
|
||||
prepare3( 4 ),
|
||||
startup1( 5 ),
|
||||
startup2( 6 ),
|
||||
startup3( 7 ),
|
||||
checkrun( 8 ),
|
||||
reprepare1( 9 ),
|
||||
reprepare2( 10 ),
|
||||
reprepare3( 11 ),
|
||||
warmup1( 12 ),
|
||||
warmup2( 13 ),
|
||||
warmup3( 14 ),
|
||||
verifyrun( 15 ),
|
||||
running( 16 ),
|
||||
cooldown1( 17 ),
|
||||
cooldown2( 18 ),
|
||||
cooldown3( 19 ),
|
||||
shutdown1( 20 ),
|
||||
shutdown2( 21 ),
|
||||
shutdown3( 22 ),
|
||||
verifystopped( 23 ),
|
||||
postshutdown1( 24 ),
|
||||
postshutdown2( 25 ),
|
||||
postshutdown3( 26 )
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The current state in the standby power sequence."
|
||||
::= { standbypower 3 }
|
||||
|
||||
ac1voltage OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The voltage of the AC input AC1 in 1/10ths of
|
||||
a volt."
|
||||
::= { standbypower 4 }
|
||||
|
||||
ac1frequency OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The frequency of the AC input AC1 in 1/100ths
|
||||
of a Hertz."
|
||||
::= { standbypower 5 }
|
||||
|
||||
ac2voltage OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The voltage of the AC input AC2 in 1/10ths of
|
||||
a volt."
|
||||
::= { standbypower 6 }
|
||||
|
||||
ac2frequency OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The frequency of the AC input AC2 in 1/100ths
|
||||
of a Hertz."
|
||||
::= { standbypower 7 }
|
||||
|
||||
mtr1voltage OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The voltage of the DC input Mtr1 in 1/10ths of
|
||||
a volt."
|
||||
::= { standbypower 8 }
|
||||
|
||||
mtr2voltage OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The voltage of the DC input Mtr2 in 1/10ths of
|
||||
a volt."
|
||||
::= { standbypower 9 }
|
||||
|
||||
pwr1voltage OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The voltage of the DC input Pwr3 in 1/10ths of
|
||||
a volt."
|
||||
::= { standbypower 10 }
|
||||
|
||||
pwr2voltage OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The voltage of the DC input Pwr2 in 1/10ths of
|
||||
a volt."
|
||||
::= { standbypower 11 }
|
||||
|
||||
shuntvoltage OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The voltage of the DC input Shunt in 1/10ths of
|
||||
a millivolt. Can be negative."
|
||||
::= { standbypower 12 }
|
||||
|
||||
temperature OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The temperature of the onboard temperature sensor
|
||||
in 1/10ths of a degree centigrade."
|
||||
::= { standbypower 13 }
|
||||
|
||||
recentunsuccessfulstarts OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "The number of times the standby power source was
|
||||
not successfully started. This counter resets
|
||||
upon a successful start. It can also be reset
|
||||
via the web interface or by writing 0 to this
|
||||
object."
|
||||
::= { standbypower 14 }
|
||||
|
||||
totalunsuccessfulstarts OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "The number of times the standby power source was
|
||||
not successfully started. This counter DOES NOT
|
||||
reset upon a successful start. It can be reset
|
||||
via the web interface or by writing 0 to this
|
||||
object."
|
||||
::= { standbypower 15 }
|
||||
|
||||
recentstalls OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "The number of times the standby power source has
|
||||
stalled. This counter resets upon a clean shutdown.
|
||||
It can also be reset via the web interface or
|
||||
by writing 0 to this object."
|
||||
::= { standbypower 16 }
|
||||
|
||||
totalstalls OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "The number of times the standby power source has
|
||||
stalled. This counter DOES NOT reset upon a clean
|
||||
shutdown. It can be reset via the web interface
|
||||
or by writing 0 to this object."
|
||||
::= { standbypower 17 }
|
||||
|
||||
numberofstarts OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "The number of times the secondary power source
|
||||
has started. This counter increments when the
|
||||
standby sequence reaches the running state. This
|
||||
counter can be reset via the web interface or
|
||||
by writing 0 to this object."
|
||||
::= { standbypower 18 }
|
||||
|
||||
numberoftransfers OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "The number of times the power has transfered from
|
||||
primary to standby, or back. A complete transfer
|
||||
cycle from primary to standby and back to primary
|
||||
will increment this counter twice. This counter
|
||||
can be reset via the web interface or by writing
|
||||
0 to this object."
|
||||
::= { standbypower 19 }
|
||||
|
||||
currenttimeonprimary OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "The amount of time the transfer switch has been
|
||||
in the primary state (position) since the most
|
||||
recent transfer to that state. This timer resets
|
||||
to zero when the transfer switch leaves the primary
|
||||
state (position). This timer can be reset via
|
||||
the web interface or by writing 0 to this object."
|
||||
::= { standbypower 20 }
|
||||
|
||||
totaltimeonprimary OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "The amount of time the transfer switch has been
|
||||
in the primary state (position) since power on
|
||||
or the last reset of this counter. This timer
|
||||
does not automatically reset. This timer can
|
||||
be reset via the web interface or by writing
|
||||
0 to this object."
|
||||
::= { standbypower 21 }
|
||||
|
||||
currenttimeonstandby OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "The amount of time the transfer switch has been
|
||||
in the standby state (position) since the most
|
||||
recent transfer to that state. This timer resets
|
||||
to zero when the transfer switch leaves the primary
|
||||
state (position). This timer can be reset via
|
||||
the web interface or by writing 0 to this object."
|
||||
::= { standbypower 22 }
|
||||
|
||||
totaltimeonstandby OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "The amount of time the transfer switch has been
|
||||
in the standby state (position) since power on
|
||||
or the last reset of this counter. This timer
|
||||
does not automatically reset. This timer can
|
||||
be reset via the web interface or by writing
|
||||
0 to this object."
|
||||
::= { standbypower 23 }
|
||||
|
||||
currentstandbyruntime OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "The amount of time the standby power source has
|
||||
been running during it's current run. This timer
|
||||
resets to zero when the standby power source
|
||||
shuts down. This timer can be reset via the web
|
||||
interface or by writing 0 to this object."
|
||||
::= { standbypower 24 }
|
||||
|
||||
totalstandbyruntime OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "The amount of time the standby power source has
|
||||
been running since power on or the last reset
|
||||
of this counter. This timer does not automatically
|
||||
reset. This timer can be reset via the web interface
|
||||
or by writing 0 to this object."
|
||||
::= { standbypower 25 }
|
||||
|
||||
laststandbyrun OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "The amount of time since the standby power source
|
||||
ran last. This timer resets upon start of the
|
||||
standby power source and starts timing upon shutdown
|
||||
of the standby power source. This timer can be
|
||||
reset via the web interface or by writing 0 to
|
||||
this object."
|
||||
::= { standbypower 26 }
|
||||
|
||||
laststandbygracefulstop OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "The amount of time since standby power source
|
||||
was gracefully shutdown. This timer resets and
|
||||
starts timing upon graceful shutdown of the standby
|
||||
power source. This timer can be reset via the
|
||||
web interface or by writing 0 to this object."
|
||||
::= { standbypower 27 }
|
||||
|
||||
laststandbyunsuccessfulstart OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "The amount of time since the last failed start
|
||||
of the standby power source . This timer resets
|
||||
and starts timing upon a unsuccessful start of
|
||||
the power source. This timer can be reset via
|
||||
the web interface or by writing 0 to this object."
|
||||
::= { standbypower 28 }
|
||||
|
||||
laststandbyfailure OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "The amount of time since the stall or failure
|
||||
while running of the standby power source . This
|
||||
timer resets and starts timing upon a stall/failure
|
||||
of the power source. This timer can be reset
|
||||
via the web interface or by writing 0 to this
|
||||
object."
|
||||
::= { standbypower 29 }
|
||||
|
||||
switch1closed OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the Switch 1 input is closed (shorted/on).
|
||||
False(2) if it is open."
|
||||
::= { standbypower 30 }
|
||||
|
||||
switch2closed OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the Switch 2 input is closed (shorted/on).
|
||||
False(2) if it is open."
|
||||
::= { standbypower 31 }
|
||||
|
||||
switch3closed OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the Switch 3 input is closed (shorted/on).
|
||||
False(2) if it is open."
|
||||
::= { standbypower 32 }
|
||||
|
||||
switch4closed OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the Switch 4 input is closed (shorted/on).
|
||||
False(2) if it is open."
|
||||
::= { standbypower 33 }
|
||||
|
||||
switch5closed OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the Switch 5 input is closed (shorted/on).
|
||||
False(2) if it is open."
|
||||
::= { standbypower 34 }
|
||||
|
||||
enabled OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the enable input is closed (shorted/on).
|
||||
False(2) if it is open."
|
||||
::= { standbypower 35 }
|
||||
|
||||
relay1on OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the Relay 1 ouput is on (C and NO connected).
|
||||
False(2) if it is off (C and NC connected)."
|
||||
::= { standbypower 36 }
|
||||
|
||||
relay2on OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the Relay 2 ouput is on (C and NO connected).
|
||||
False(2) if it is off (C and NC connected)."
|
||||
::= { standbypower 37 }
|
||||
|
||||
relay3on OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the Relay 3 ouput is on (C and NO connected).
|
||||
False(2) if it is off (C and NC connected)."
|
||||
::= { standbypower 38 }
|
||||
|
||||
relay4on OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the Relay 4 ouput is on (C and NO connected).
|
||||
False(2) if it is off (C and NC connected)."
|
||||
::= { standbypower 39 }
|
||||
|
||||
relay5on OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the Relay 5 output is on (C and NO
|
||||
connected). False(2) if it is off (C and NC connected)."
|
||||
::= { standbypower 40 }
|
||||
|
||||
relay6on OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the Relay 6 output is on (C and NO
|
||||
connected). False(2) if it is off (C and NC connected)."
|
||||
::= { standbypower 41 }
|
||||
|
||||
relay7on OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the Relay 7 output is on (C and NO
|
||||
connected). False(2) if it is off (C and NC connected)."
|
||||
::= { standbypower 42 }
|
||||
|
||||
ruleswitchstandby OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the switch to standby rule is true.
|
||||
False(2) if it is not."
|
||||
::= { standbypower 43 }
|
||||
|
||||
rulereturnprimary OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the return to primary rule is true.
|
||||
False(2) if it is not."
|
||||
::= { standbypower 44 }
|
||||
|
||||
rulestandbygood OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the standby power good rule is true.
|
||||
False(2) if it is not."
|
||||
::= { standbypower 45 }
|
||||
|
||||
rulestopstandby OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the stop standby and consider it failed
|
||||
rule is true. False(2) if it is not."
|
||||
::= { standbypower 46 }
|
||||
|
||||
ruleexercisestandby OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the exercise standby without transfer
|
||||
rule is true. False(2) if it is not."
|
||||
::= { standbypower 47 }
|
||||
|
||||
webcontrol1 OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the webcontrol 1 virtual toggle switch
|
||||
is in the on position. False(2) if it is not.
|
||||
This value can be written to affect the position
|
||||
of the toggle switch."
|
||||
::= { standbypower 48 }
|
||||
|
||||
webcontrol2 OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the webcontrol 2 virtual toggle switch
|
||||
is in the on position. False(2) if it is not.
|
||||
This value can be written to affect the position
|
||||
of the toggle switch."
|
||||
::= { standbypower 49 }
|
||||
|
||||
webcontrol3 OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the webcontrol 3 virtual toggle switch
|
||||
is in the on position. False(2) if it is not.
|
||||
This value can be written to affect the position
|
||||
of the toggle switch."
|
||||
::= { standbypower 50 }
|
||||
|
||||
webcontrol4 OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the webcontrol 4 virtual toggle switch
|
||||
is in the on position. False(2) if it is not.
|
||||
This value can be written to affect the position
|
||||
of the toggle switch."
|
||||
::= { standbypower 51 }
|
||||
|
||||
webcontrol5 OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the webcontrol 5 virtual toggle switch
|
||||
is in the on position. False(2) if it is not.
|
||||
This value can be written to affect the position
|
||||
of the toggle switch."
|
||||
::= { standbypower 52 }
|
||||
|
||||
webcontrol6 OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the webcontrol 6 virtual toggle switch
|
||||
is in the on position. False(2) if it is not.
|
||||
This value can be written to affect the position
|
||||
of the toggle switch."
|
||||
::= { standbypower 53 }
|
||||
|
||||
webcontrol7 OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the webcontrol 7 virtual toggle switch
|
||||
is in the on position. False(2) if it is not.
|
||||
This value can be written to affect the position
|
||||
of the toggle switch."
|
||||
::= { standbypower 54 }
|
||||
|
||||
webcontrol8 OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "True(1) if the webcontrol 8 virtual toggle switch
|
||||
is in the on position. False(2) if it is not.
|
||||
This value can be written to affect the position
|
||||
of the toggle switch."
|
||||
::= { standbypower 55 }
|
||||
|
||||
standbypowerConformance OBJECT IDENTIFIER ::= { standbypower 256 }
|
||||
|
||||
standbypowerGroups OBJECT IDENTIFIER ::= { standbypowerConformance 1 }
|
||||
|
||||
packetfluxStandbypowerAllObjects OBJECT-GROUP
|
||||
OBJECTS {
|
||||
powercontrollerstate,
|
||||
transferswitchstate,
|
||||
standbypowerstate,
|
||||
ac1voltage,
|
||||
ac1frequency,
|
||||
ac2voltage,
|
||||
ac2frequency,
|
||||
mtr1voltage,
|
||||
mtr2voltage,
|
||||
pwr1voltage,
|
||||
pwr2voltage,
|
||||
shuntvoltage,
|
||||
temperature,
|
||||
recentunsuccessfulstarts,
|
||||
totalunsuccessfulstarts,
|
||||
recentstalls,
|
||||
totalstalls,
|
||||
numberofstarts,
|
||||
numberoftransfers,
|
||||
currenttimeonprimary,
|
||||
totaltimeonprimary,
|
||||
currenttimeonstandby,
|
||||
totaltimeonstandby,
|
||||
currentstandbyruntime,
|
||||
totalstandbyruntime,
|
||||
laststandbyrun,
|
||||
laststandbygracefulstop,
|
||||
laststandbyunsuccessfulstart,
|
||||
laststandbyfailure,
|
||||
switch1closed,
|
||||
switch2closed,
|
||||
switch3closed,
|
||||
switch4closed,
|
||||
switch5closed,
|
||||
enabled,
|
||||
relay1on,
|
||||
relay2on,
|
||||
relay3on,
|
||||
relay4on,
|
||||
relay5on,
|
||||
relay6on,
|
||||
relay7on,
|
||||
ruleswitchstandby,
|
||||
rulereturnprimary,
|
||||
rulestandbygood,
|
||||
rulestopstandby,
|
||||
ruleexercisestandby,
|
||||
webcontrol1,
|
||||
webcontrol2,
|
||||
webcontrol3,
|
||||
webcontrol4,
|
||||
webcontrol5,
|
||||
webcontrol6,
|
||||
webcontrol7,
|
||||
webcontrol8
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION "This automatically created object group contains
|
||||
all those objects that do not belong to any other
|
||||
OBJECT-GROUP"
|
||||
::= { standbypowerGroups 1 }
|
||||
|
||||
|
||||
END
|
||||
|