initial commit; version 22.5.12042
This commit is contained in:
577
mibs/netinsight/NETI-COMMON-MIB
Normal file
577
mibs/netinsight/NETI-COMMON-MIB
Normal file
@ -0,0 +1,577 @@
|
||||
NETI-COMMON-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- -------------------------------------------------------------
|
||||
-- The common OIDs and definitions in the Net Insight
|
||||
-- enterprise MIB
|
||||
-- -------------------------------------------------------------
|
||||
|
||||
IMPORTS
|
||||
TEXTUAL-CONVENTION
|
||||
FROM SNMPv2-TC
|
||||
enterprises, MODULE-IDENTITY
|
||||
FROM SNMPv2-SMI;
|
||||
|
||||
|
||||
-- -------------------------------------------------------------
|
||||
-- The enterprise OID
|
||||
-- -------------------------------------------------------------
|
||||
|
||||
netinsight MODULE-IDENTITY
|
||||
LAST-UPDATED
|
||||
"201410231300Z"
|
||||
ORGANIZATION
|
||||
"Net Insight AB"
|
||||
CONTACT-INFO
|
||||
"Net Insight AB
|
||||
Box 42093
|
||||
SE-126 14 Stockholm
|
||||
Sweden
|
||||
Tel +46-8-685 0400
|
||||
info@netinsight.net"
|
||||
DESCRIPTION
|
||||
"Common definitions for the Net Insight MIB tree.
|
||||
This in the `root' in the Net Insight MIB tree."
|
||||
|
||||
REVISION
|
||||
"201410231300Z"
|
||||
DESCRIPTION
|
||||
"Added object for new unit Nimbra VA 220: nimbraVA220."
|
||||
|
||||
REVISION
|
||||
"201404011000Z"
|
||||
DESCRIPTION
|
||||
"Added NETI-TRUNK-MIB."
|
||||
|
||||
REVISION
|
||||
"201310100900Z"
|
||||
DESCRIPTION
|
||||
"Added object for new unit: nimbra390."
|
||||
|
||||
REVISION
|
||||
"201306031100Z"
|
||||
DESCRIPTION
|
||||
"Replaced NETI-EVENT-MIB with NETI-EVT-MIB."
|
||||
|
||||
REVISION
|
||||
"201301301300Z"
|
||||
DESCRIPTION
|
||||
"Added object for new units: nimbraVA210.
|
||||
Added root for new mib NETI-VA-INET-TRANSPORT-MIB.
|
||||
|
||||
Added object for new unit: nimbra640.
|
||||
|
||||
Added objects for new boards:
|
||||
nimbra340ModuleTypesAccess8xSDI,
|
||||
nimbra680ModuleTypesSwitch160Gbps,
|
||||
nimbra680ModuleTypesAccess8xVideo,
|
||||
nimbra680ModuleTypesAccess8xASIAES,
|
||||
nimbra680ModuleTypesAccess2x10GbE"
|
||||
|
||||
REVISION
|
||||
"201209121100Z"
|
||||
DESCRIPTION
|
||||
"Added object for new unit: nimbra240."
|
||||
|
||||
REVISION
|
||||
"201203220920Z"
|
||||
DESCRIPTION
|
||||
"Added object for new unit: nimbra310."
|
||||
|
||||
REVISION
|
||||
"201203161300Z"
|
||||
DESCRIPTION
|
||||
"Corrected root object to nimbra230 mibs."
|
||||
|
||||
REVISION
|
||||
"201103251400Z"
|
||||
DESCRIPTION
|
||||
"Added object for new units:
|
||||
nimbra230 and nimbra320.
|
||||
|
||||
Added object for new MIB:
|
||||
netiNvMIB"
|
||||
|
||||
REVISION
|
||||
"201011100800Z"
|
||||
DESCRIPTION
|
||||
"Added object for new unit:
|
||||
nimbra380
|
||||
|
||||
Added object for new board:
|
||||
nimbra380ModuleTypesAccess8xGbE"
|
||||
|
||||
REVISION
|
||||
"201002041500Z"
|
||||
DESCRIPTION
|
||||
"Added objects for new units:
|
||||
nimbra130,
|
||||
nimbra360Gold
|
||||
|
||||
Added objects for new thermometers:
|
||||
nimbraOneThermometer,
|
||||
nimbra340Thermometer,
|
||||
nimbra680Thermometer
|
||||
|
||||
Added objects for new boards:
|
||||
nimbraOneModuleTypesAuxGPIO,
|
||||
nimbra340ModuleTypesAuxGPIO,
|
||||
nimbraOneModuleTypesTrunk3xIP,
|
||||
nimbra340ModuleTypesTrunk3xIP,
|
||||
nimbra680ModuleTypesIfTrunk6xIP,
|
||||
nimbraOneModuleTypesTrunkAccess4xDS3E3,
|
||||
nimbra340ModuleTypesTrunkAccess4xDS3E3,
|
||||
nimbra680ModuleTypesAccess8xJPEG2000"
|
||||
|
||||
REVISION
|
||||
"200812191400Z"
|
||||
DESCRIPTION
|
||||
"Added Nimbra Vision group nimbravision."
|
||||
|
||||
REVISION
|
||||
"200812121300Z"
|
||||
DESCRIPTION
|
||||
"Updated comments.
|
||||
Corrected date on previous revision (wrong year)."
|
||||
|
||||
REVISION
|
||||
"200810151200Z"
|
||||
DESCRIPTION
|
||||
"Added object for new board:
|
||||
nimbra680ModuleTypesAccess8x3Gbps"
|
||||
|
||||
REVISION
|
||||
"200806191000Z"
|
||||
DESCRIPTION
|
||||
"Added objects for new unit:
|
||||
nimbra688"
|
||||
|
||||
REVISION
|
||||
"200707311500Z"
|
||||
DESCRIPTION
|
||||
"Added objects for new boards:
|
||||
nimbraOneModuleTypesAccess8xAESEBU,
|
||||
nimbra340ModuleTypesAccess8xAESEBU,
|
||||
nimbra680ModuleTypesSwitch80Gbps,
|
||||
nimbra680ModuleTypesAccess8xHDSDI,
|
||||
nimbra680ModuleTypesAccess8xGbE,
|
||||
nimbra680ModuleTypesAccess8xASI,
|
||||
nimbra680ModuleTypesAuxGPIO"
|
||||
|
||||
REVISION
|
||||
"200701261100Z"
|
||||
DESCRIPTION
|
||||
"Added object for Nimbra 360 trunk."
|
||||
|
||||
REVISION
|
||||
"200608170830Z"
|
||||
DESCRIPTION
|
||||
"Added objects for Nimbra 340HD:
|
||||
nimbra340HD, nimbra340ModuleTypesAccessHDSDI.
|
||||
Added object for Nimbra 360."
|
||||
|
||||
REVISION
|
||||
"200512150000Z"
|
||||
DESCRIPTION
|
||||
"Added objects for Nimbra 340.
|
||||
Added new PIU objects for Nimbra One.
|
||||
Removed of obsoleted and never used objects.
|
||||
Reformatted text."
|
||||
|
||||
REVISION
|
||||
"200303250000Z"
|
||||
DESCRIPTION
|
||||
"Added objects that is used by entPhysicalVendorType in ENTITY-MIB
|
||||
described in RFC2737:
|
||||
|
||||
nimbraOneModuleTypesDtm622
|
||||
nimbraOneModuleTypesAccessGigabitEthernet
|
||||
nimbraOneModuleTypesAccessASIRight
|
||||
nimbraOneModuleTypesAccessASILeft"
|
||||
::= {enterprises 2928}
|
||||
|
||||
-- -------------------------------------------------------------
|
||||
-- Textual conventions
|
||||
-- -------------------------------------------------------------
|
||||
|
||||
FaultStatus ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Shows the status of a fault that causes an alarm.
|
||||
Each fault should have its own variable and this
|
||||
OID is used as the identifier of the alarm.
|
||||
|
||||
ok
|
||||
The fault is not present and the alarm is not raised.
|
||||
|
||||
fault
|
||||
The fault is present and and alarm is raised."
|
||||
SYNTAX INTEGER {
|
||||
ok(1),
|
||||
fault(2) }
|
||||
|
||||
|
||||
-- -------------------------------------------------------------
|
||||
-- Product definitions. The OID's are for identifying the agent
|
||||
-- software and used in sysObjectID in the MIB-II Systems Group.
|
||||
-- -------------------------------------------------------------
|
||||
netiReg OBJECT IDENTIFIER ::= {netinsight 1}
|
||||
|
||||
nimbraOne OBJECT IDENTIFIER ::= {netiReg 1} -- deprecated
|
||||
nimbra101 OBJECT IDENTIFIER ::= {netiReg 2} -- deprecated
|
||||
nimbra210 OBJECT IDENTIFIER ::= {netiReg 3} -- deprecated
|
||||
nimbra220 OBJECT IDENTIFIER ::= {netiReg 4} -- deprecated
|
||||
nimbra290 OBJECT IDENTIFIER ::= {netiReg 5} -- deprecated
|
||||
nimbraTwo OBJECT IDENTIFIER ::= {netiReg 6} -- deprecated
|
||||
netiRegGeneric OBJECT IDENTIFIER ::= {netiReg 7} -- for use as root for objects independent of type
|
||||
nimbra291 OBJECT IDENTIFIER ::= {netiReg 8} -- deprecated
|
||||
nimbra340 OBJECT IDENTIFIER ::= {netiReg 9}
|
||||
nimbra680 OBJECT IDENTIFIER ::= {netiReg 10}
|
||||
nimbra340HD OBJECT IDENTIFIER ::= {netiReg 11}
|
||||
nimbra360 OBJECT IDENTIFIER ::= {netiReg 12}
|
||||
nimbra360Gold OBJECT IDENTIFIER ::= {nimbra360 1} -- Is subclass of Nimbra 360
|
||||
nimbra688 OBJECT IDENTIFIER ::= {netiReg 13}
|
||||
nimbra130 OBJECT IDENTIFIER ::= {netiReg 14}
|
||||
nimbra380 OBJECT IDENTIFIER ::= {netiReg 15}
|
||||
nimbra230 OBJECT IDENTIFIER ::= {netiReg 16}
|
||||
nimbra320 OBJECT IDENTIFIER ::= {netiReg 17}
|
||||
nimbra140 OBJECT IDENTIFIER ::= {netiReg 18}
|
||||
nimbra310 OBJECT IDENTIFIER ::= {netiReg 19}
|
||||
nimbra240 OBJECT IDENTIFIER ::= {netiReg 20}
|
||||
nimbra640 OBJECT IDENTIFIER ::= {netiReg 21}
|
||||
nimbraVA210 OBJECT IDENTIFIER ::= {netiReg 22}
|
||||
nimbraVA210FV OBJECT IDENTIFIER ::= {nimbraVA210 1}
|
||||
nimbraVA210DCV1 OBJECT IDENTIFIER ::= {nimbraVA210 2}
|
||||
nimbraVA210DCV2 OBJECT IDENTIFIER ::= {nimbraVA210 3}
|
||||
nimbra390 OBJECT IDENTIFIER ::= {netiReg 23}
|
||||
nimbraVA220 OBJECT IDENTIFIER ::= {netiReg 25}
|
||||
|
||||
|
||||
|
||||
|
||||
-- -------------------------------------------------------------
|
||||
-- Product definitions. The OID's are for identifying the
|
||||
-- type of physical entity and is used in entPhysicalVendorType
|
||||
-- in the ENTITY-MIB Physical Table.
|
||||
-- -------------------------------------------------------------
|
||||
|
||||
--
|
||||
-- NimbraOne
|
||||
-- (obsoleted since GX4.12.0)
|
||||
--
|
||||
|
||||
nimbraOneChassisTypes OBJECT IDENTIFIER ::= {nimbraOne 1}
|
||||
nimbraOneBaseUnit OBJECT IDENTIFIER ::= {nimbraOneChassisTypes 1}
|
||||
nimbraOneBackplaneTypes OBJECT IDENTIFIER ::= {nimbraOne 2}
|
||||
nimbraOneBackplane OBJECT IDENTIFIER ::= {nimbraOneBackplaneTypes 1}
|
||||
nimbraOneContainerTypes OBJECT IDENTIFIER ::= {nimbraOne 3}
|
||||
nimbraOneSlot OBJECT IDENTIFIER ::= {nimbraOneContainerTypes 1}
|
||||
nimbraOnePowerSupplyTypes OBJECT IDENTIFIER ::= {nimbraOne 4}
|
||||
nimbraOnePowerSupply OBJECT IDENTIFIER ::= {nimbraOnePowerSupplyTypes 1}
|
||||
nimbraOneFanTypes OBJECT IDENTIFIER ::= {nimbraOne 5}
|
||||
nimbraOneFan OBJECT IDENTIFIER ::= {nimbraOneFanTypes 1}
|
||||
nimbraOneModuleTypes OBJECT IDENTIFIER ::= {nimbraOne 6} -- Plug-In Units
|
||||
|
||||
|
||||
-- Management modules (Node Controller)
|
||||
nimbraOneModuleTypesMgmt OBJECT IDENTIFIER ::= {nimbraOneModuleTypes 1}
|
||||
nimbraOneModuleTypesMgmtControlModule OBJECT IDENTIFIER ::= {nimbraOneModuleTypesMgmt 1}
|
||||
|
||||
|
||||
-- Trunk modules
|
||||
nimbraOneModuleTypesDtm OBJECT IDENTIFIER ::= {nimbraOneModuleTypes 2}
|
||||
|
||||
-- (obsoleted since GX3.3.2)
|
||||
nimbraOneModuleTypesDtm850ShortHaulRight OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 1} -- MAU850
|
||||
nimbraOneModuleTypesDtm850ShortHaulLeft OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 2} -- MAU850
|
||||
nimbraOneModuleTypesDtm850LongHaulRight OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 3} -- MAU850
|
||||
nimbraOneModuleTypesDtm850LongHaulLeft OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 4} -- MAU850
|
||||
nimbraOneModuleTypesDtm1000ShortHaulRight OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 5} -- MAU1000
|
||||
nimbraOneModuleTypesDtm1000ShortHaulLeft OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 6} -- MAU1000
|
||||
nimbraOneModuleTypesDtm1000LongHaulRight OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 7} -- MAU1000
|
||||
nimbraOneModuleTypesDtm1000LongHaulLeft OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 8} -- MAU1000
|
||||
nimbraOneModuleTypesDtm150Right OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 9} -- MAU150
|
||||
nimbraOneModuleTypesDtm150Left OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 10} -- MAU150
|
||||
nimbraOneModuleTypesDtm622 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 11} -- MAU600
|
||||
|
||||
-- (obsoleted since GX4.12.0)
|
||||
nimbraOneModuleTypesTrunk1Gbps OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 12} -- MAU1000
|
||||
nimbraOneModuleTypesTrunkDS3 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 13} -- MAU50
|
||||
nimbraOneModuleTypesTrunkOC3 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 14} -- MAU150
|
||||
nimbraOneModuleTypesTrunk4xOC3 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 15} -- MAU155
|
||||
nimbraOneModuleTypesTrunkOC12 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 16} -- MAU600
|
||||
nimbraOneModuleTypesTrunkOC48 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 17} -- MAU2500
|
||||
nimbraOneModuleTypesTrunk3xIP OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 18} -- IP/Ethernet
|
||||
|
||||
|
||||
-- Access modules
|
||||
nimbraOneModuleTypesAccess OBJECT IDENTIFIER ::= {nimbraOneModuleTypes 3}
|
||||
|
||||
-- (obsoleted since GX3.2.2)
|
||||
nimbraOneModuleTypesAccessE1Right OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 1} -- E1
|
||||
nimbraOneModuleTypesAccessE1Left OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 2} -- E1
|
||||
nimbraOneModuleTypesAccessT1Right OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 3} -- T1
|
||||
nimbraOneModuleTypesAccessT1Left OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 4} -- T1
|
||||
nimbraOneModuleTypesAccessVideo270Right OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 5} -- SDI
|
||||
nimbraOneModuleTypesAccessVideo270Left OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 6} -- SDI
|
||||
nimbraOneModuleTypesAccessEthernet8pRight OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 7} -- FEC
|
||||
nimbraOneModuleTypesAccessEthernet8pLeft OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 8} -- FEC
|
||||
nimbraOneModuleTypesAccessGigabitEthernet OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 9} -- GEC
|
||||
nimbraOneModuleTypesAccessASIRight OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 11} -- ASI
|
||||
nimbraOneModuleTypesAccessASILeft OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 12} -- ASI
|
||||
|
||||
-- (obsoleted since GX4.12.0)
|
||||
nimbraOneModuleTypesAccessGbE OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 13} -- GEC
|
||||
nimbraOneModuleTypesAccess8xEth OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 14} -- FEC
|
||||
nimbraOneModuleTypesAccessASI OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 15} -- ASI
|
||||
nimbraOneModuleTypesAccessSDI OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 16} -- SDI
|
||||
nimbraOneModuleTypesAccess4xOC3 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 17} -- SAC155
|
||||
nimbraOneModuleTypesAccessE1 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 18} -- T1
|
||||
nimbraOneModuleTypesAccessT1 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 19} -- E1
|
||||
nimbraOneModuleTypesAccess8xASI OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 20} -- 8x ASI
|
||||
nimbraOneModuleTypesAccess8xAESEBU OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 21} -- 8x AES/EBU
|
||||
|
||||
|
||||
-- Trunk and Access modules
|
||||
nimbraOneModuleTypesTrunkAccess OBJECT IDENTIFIER ::= {nimbraOneModuleTypes 4}
|
||||
|
||||
nimbraOneModuleTypesTrunkAccess4xDS3E3 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesTrunkAccess 1} -- 4x DS3/E3
|
||||
|
||||
|
||||
-- Auxillary Modules
|
||||
nimbraOneModuleTypesAux OBJECT IDENTIFIER ::= {nimbraOneModuleTypes 5}
|
||||
|
||||
nimbraOneModuleTypesAuxGPIO OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAux 1} -- GPIO Alarm Module
|
||||
|
||||
|
||||
-- Thermometers
|
||||
nimbraOneThermometerTypes OBJECT IDENTIFIER ::= {nimbraOne 7}
|
||||
nimbraOneThermometer OBJECT IDENTIFIER ::= {nimbraOneThermometerTypes 1}
|
||||
|
||||
|
||||
--
|
||||
-- Nimbra290
|
||||
-- (obsoleted since GX3.2.8)
|
||||
--
|
||||
nimbra290ChassisTypes OBJECT IDENTIFIER ::= {nimbra290 1}
|
||||
nimbra290BaseUnit OBJECT IDENTIFIER ::= {nimbra290ChassisTypes 1}
|
||||
nimbra290PowerSupplyTypes OBJECT IDENTIFIER ::= {nimbra290 2}
|
||||
nimbra290PowerUnit OBJECT IDENTIFIER ::= {nimbra290PowerSupplyTypes 1}
|
||||
nimbra290FanTypes OBJECT IDENTIFIER ::= {nimbra290 3}
|
||||
nimbra290Fan OBJECT IDENTIFIER ::= {nimbra290FanTypes 1}
|
||||
|
||||
|
||||
--
|
||||
-- Nimbra340
|
||||
--
|
||||
|
||||
nimbra340ChassisTypes OBJECT IDENTIFIER ::= {nimbra340 1}
|
||||
nimbra340ContainerTypes OBJECT IDENTIFIER ::= {nimbra340 3}
|
||||
nimbra340PowerSupplyTypes OBJECT IDENTIFIER ::= {nimbra340 4}
|
||||
nimbra340FanTypes OBJECT IDENTIFIER ::= {nimbra340 5}
|
||||
nimbra340ModuleTypes OBJECT IDENTIFIER ::= {nimbra340 6} -- Plug-In Units
|
||||
|
||||
|
||||
-- Management modules (Built-in Node Controller)
|
||||
nimbra340ModuleTypesMgmt OBJECT IDENTIFIER ::= {nimbra340ModuleTypes 1}
|
||||
nimbra340ModuleTypesMgmtControlModule OBJECT IDENTIFIER ::= {nimbra340ModuleTypesMgmt 1}
|
||||
|
||||
|
||||
-- Trunk modules for N340, N360 and N380
|
||||
nimbra340ModuleTypesDtm OBJECT IDENTIFIER ::= {nimbra340ModuleTypes 2}
|
||||
|
||||
nimbra340ModuleTypesTrunk1Gbps OBJECT IDENTIFIER ::= {nimbra340ModuleTypesDtm 1} -- MAU1000
|
||||
nimbra340ModuleTypesTrunkDS3 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesDtm 2} -- MAU50
|
||||
nimbra340ModuleTypesTrunkOC3 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesDtm 3} -- MAU150
|
||||
nimbra340ModuleTypesTrunk4xOC3 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesDtm 4} -- MAU155
|
||||
nimbra340ModuleTypesTrunkOC12 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesDtm 5} -- MAU600
|
||||
nimbra340ModuleTypesTrunkOC48 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesDtm 6} -- MAU2500
|
||||
nimbra340ModuleTypesTrunk3xIP OBJECT IDENTIFIER ::= {nimbra340ModuleTypesDtm 7} -- 3xIP/Ethernet
|
||||
|
||||
|
||||
-- Access modules for N340, N360 and N380
|
||||
nimbra340ModuleTypesAccess OBJECT IDENTIFIER ::= {nimbra340ModuleTypes 3}
|
||||
|
||||
nimbra340ModuleTypesAccessGbE OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 1} -- GEC
|
||||
nimbra340ModuleTypesAccess8xEth OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 2} -- FEC
|
||||
nimbra340ModuleTypesAccessASI OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 3} -- ASI
|
||||
nimbra340ModuleTypesAccessSDI OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 4} -- SD SDI
|
||||
nimbra340ModuleTypesAccess4xOC3 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 5} -- SAC155
|
||||
nimbra340ModuleTypesAccessE1 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 6} -- T1
|
||||
nimbra340ModuleTypesAccessT1 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 7} -- E1
|
||||
nimbra340ModuleTypesAccess8xASI OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 8} -- 8x ASI
|
||||
nimbra340ModuleTypesAccessHDSDI OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 9} -- HD SDI
|
||||
nimbra340ModuleTypesAccess8xAESEBU OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 10} -- 8x AES/EBU
|
||||
nimbra340ModuleTypesAccess8xSDI OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 11} -- 8x SDI
|
||||
|
||||
|
||||
|
||||
-- Built in modules for N340, N360 and N380. These modules are not
|
||||
-- plug-in units, but are still modeled as such. Becase the N340, N360
|
||||
-- and N380 are all variants that differs only on the set of these
|
||||
-- fixed built-in modules, these fixed modules are grouped together
|
||||
-- with the N340 modules.
|
||||
|
||||
-- Trunk modules
|
||||
nimbra360ModuleTypesDtm OBJECT IDENTIFIER ::= {nimbra340ModuleTypes 4}
|
||||
nimbra360ModuleTypesTrunkFunction OBJECT IDENTIFIER ::= {nimbra360ModuleTypesDtm 1} -- STM module
|
||||
|
||||
|
||||
-- Auxillary Modules
|
||||
nimbra340ModuleTypesAux OBJECT IDENTIFIER ::= {nimbra340ModuleTypes 5}
|
||||
nimbra340ModuleTypesAuxGPIO OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAux 1} -- GPIO Alarm Module
|
||||
|
||||
|
||||
-- Trunk and Access modules
|
||||
nimbra340ModuleTypesTrunkAccess OBJECT IDENTIFIER ::= {nimbra340ModuleTypes 6}
|
||||
nimbra340ModuleTypesTrunkAccess4xDS3E3 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesTrunkAccess 1} -- 4x DS3/E3
|
||||
|
||||
|
||||
-- Access Modules built-in on N380
|
||||
nimbra380ModuleTypesAccess OBJECT IDENTIFIER ::= {nimbra340ModuleTypes 7 }
|
||||
nimbra380ModuleTypesAccess8xGbE OBJECT IDENTIFIER ::= {nimbra380ModuleTypesAccess 1}
|
||||
|
||||
|
||||
-- Thermometers built-in
|
||||
nimbra340ThermometerTypes OBJECT IDENTIFIER ::= {nimbra340 7}
|
||||
nimbra340Thermometer OBJECT IDENTIFIER ::= {nimbra340ThermometerTypes 1}
|
||||
|
||||
|
||||
|
||||
|
||||
--
|
||||
-- Nimbra 680
|
||||
--
|
||||
|
||||
nimbra680ChassisTypes OBJECT IDENTIFIER ::= {nimbra680 1}
|
||||
nimbra680ContainerTypes OBJECT IDENTIFIER ::= {nimbra680 3}
|
||||
nimbra680PowerSupplyTypes OBJECT IDENTIFIER ::= {nimbra680 4}
|
||||
nimbra680FanTypes OBJECT IDENTIFIER ::= {nimbra680 5}
|
||||
nimbra680ModuleTypes OBJECT IDENTIFIER ::= {nimbra680 6} -- Plug-In Units
|
||||
|
||||
|
||||
-- Power
|
||||
nimbra680PowerSupplyTypesPCU OBJECT IDENTIFIER ::= {nimbra680PowerSupplyTypes 1} -- DC/DC converter
|
||||
nimbra680PowerSupplyTypesPSU OBJECT IDENTIFIER ::= {nimbra680PowerSupplyTypes 2} -- Rectifier
|
||||
|
||||
|
||||
-- Fans
|
||||
nimbra680FanTypesFan OBJECT IDENTIFIER ::= {nimbra680FanTypes 1}
|
||||
|
||||
|
||||
-- Management modules
|
||||
nimbra680ModuleTypesMgmt OBJECT IDENTIFIER ::= {nimbra680ModuleTypes 1}
|
||||
|
||||
nimbra680ModuleTypesMgmtControlModule OBJECT IDENTIFIER ::= {nimbra680ModuleTypesMgmt 1}
|
||||
|
||||
|
||||
-- Interface modules
|
||||
nimbra680ModuleTypesIf OBJECT IDENTIFIER ::= {nimbra680ModuleTypes 2}
|
||||
|
||||
nimbra680ModuleTypesIfTrunk4xOC3 OBJECT IDENTIFIER ::= {nimbra680ModuleTypesIf 1}
|
||||
nimbra680ModuleTypesIfTrunk4xOC12 OBJECT IDENTIFIER ::= {nimbra680ModuleTypesIf 2}
|
||||
nimbra680ModuleTypesIfTrunk2xOC48 OBJECT IDENTIFIER ::= {nimbra680ModuleTypesIf 3}
|
||||
nimbra680ModuleTypesIfTrunk4xOC48 OBJECT IDENTIFIER ::= {nimbra680ModuleTypesIf 4}
|
||||
nimbra680ModuleTypesIfTrunkOC192 OBJECT IDENTIFIER ::= {nimbra680ModuleTypesIf 5}
|
||||
nimbra680ModuleTypesIfTrunk6xIP OBJECT IDENTIFIER ::= {nimbra680ModuleTypesIf 6}
|
||||
|
||||
|
||||
-- Switch modules
|
||||
nimbra680ModuleTypesSwitch OBJECT IDENTIFIER ::= {nimbra680ModuleTypes 3}
|
||||
|
||||
nimbra680ModuleTypesSwitch40Gbps OBJECT IDENTIFIER ::= {nimbra680ModuleTypesSwitch 1}
|
||||
nimbra680ModuleTypesSwitch80Gbps OBJECT IDENTIFIER ::= {nimbra680ModuleTypesSwitch 2}
|
||||
nimbra680ModuleTypesSwitch160Gbps OBJECT IDENTIFIER ::= {nimbra680ModuleTypesSwitch 3}
|
||||
|
||||
|
||||
-- Access Modules
|
||||
nimbra680ModuleTypesAccess OBJECT IDENTIFIER ::= {nimbra680ModuleTypes 4}
|
||||
|
||||
nimbra680ModuleTypesAccess8xHDSDI OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAccess 1} -- 8x HD/SD SDI
|
||||
nimbra680ModuleTypesAccess8xGbE OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAccess 2} -- 8x GbE
|
||||
nimbra680ModuleTypesAccess8xASI OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAccess 3} -- 8x ASI
|
||||
nimbra680ModuleTypesAccess8x3Gbps OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAccess 4} -- 8x 3G
|
||||
nimbra680ModuleTypesAccess8xJPEG2000 OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAccess 5} -- 8x JPEG2000
|
||||
nimbra680ModuleTypesAccess8xVideo OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAccess 6} -- 8x Video
|
||||
nimbra680ModuleTypesAccess8xASIAES OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAccess 7} -- 8x ASI/AES
|
||||
nimbra680ModuleTypesAccess2x10GbE OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAccess 8} -- 2x 10GbE
|
||||
|
||||
|
||||
-- Auxillary Modules
|
||||
nimbra680ModuleTypesAux OBJECT IDENTIFIER ::= {nimbra680ModuleTypes 5}
|
||||
|
||||
nimbra680ModuleTypesAuxGPIO OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAux 1} -- GPIO Alarm Module
|
||||
|
||||
|
||||
-- Thermometers
|
||||
nimbra680ThermometerTypes OBJECT IDENTIFIER ::= {nimbra680 7}
|
||||
|
||||
nimbra680Thermometer OBJECT IDENTIFIER ::= {nimbra680ThermometerTypes 1}
|
||||
|
||||
|
||||
-- -------------------------------------------------------------
|
||||
-- The MIB tree
|
||||
-- -------------------------------------------------------------
|
||||
|
||||
-- Mib tree for generic MIBs. Objects and events not associated
|
||||
-- with a specific product.
|
||||
netiGeneric OBJECT IDENTIFIER ::= {netinsight 2}
|
||||
-- MIBs assigned in the generic subtree:
|
||||
-- NETI-EVENT-MIB netiEventMIB ::= { netiGeneric 1 }
|
||||
-- NETI-ETH-MIB netiEthMIB ::= { netiGeneric 2 }
|
||||
-- NETI-TRUNK-MIB netiTrunkMIB ::= { netiGeneric 3 }
|
||||
-- NETI-VA-INET-TRANSPORT-MIB netiVaInetTrspMIB ::= { netiGeneric 4 }
|
||||
|
||||
|
||||
-- Product specific mibs. Objects and events associated with a
|
||||
-- specific product.
|
||||
netiProducts OBJECT IDENTIFIER ::= {netinsight 3}
|
||||
nimbravision OBJECT IDENTIFIER ::= {netiProducts 1}
|
||||
-- MIBs assigned in the nimbravision subtree
|
||||
-- NETI-NV-ALARM-MIB netiNvAlarmMIB ::= { nimbravision 1 }
|
||||
-- NETI-NV-MIB netiNvMIB ::= { nimbravision 2 }
|
||||
prodNimbra230 OBJECT IDENTIFIER ::= {netiProducts 2}
|
||||
-- nimbra230MIB ::= { netiProducts 2 }
|
||||
-- nimbra140MIB ::= { netiProducts 3 }
|
||||
|
||||
|
||||
|
||||
-- Agent implementation profiles/capabilities
|
||||
netiCaps OBJECT IDENTIFIER ::= {netinsight 4}
|
||||
|
||||
|
||||
-- Requirement specifications
|
||||
netiReqs OBJECT IDENTIFIER ::= {netinsight 5}
|
||||
|
||||
|
||||
-- -------------------------------------------------------------
|
||||
-- Experimental MIBs, initially for objects and events
|
||||
-- under development. The structure is the same as for
|
||||
-- netiGeneric above.
|
||||
-- -------------------------------------------------------------
|
||||
-- MIBs assigned in the experimental generic subtree:
|
||||
-- NETI-ACCOUNTING-MIB ::= { netiExperimentalGeneric 1 } - deprecated
|
||||
-- NETI-ALARM-MIB netiAlarmMIB ::= { netiExperimentalGeneric 2 } - deprecated
|
||||
-- NETI-DLE-MIB netiDLEMIB ::= { netiExperimentalGeneric 3 } - deprecated
|
||||
-- NETI-DTM-MIB netiDTMMIB ::= { netiExperimentalGeneric 4 }
|
||||
-- NETI-TUNNEL-MIB netiTunnelMIB ::= { netiExperimentalGeneric 5 } - deprecated
|
||||
-- NETI-SYSTEM-MIB netiSystemMIB ::= { netiExperimentalGeneric 6 } - deprecated
|
||||
-- NETI-CONFIG-MIB netiConfigMIB ::= { netiExperimentalGeneric 7 }
|
||||
-- NETI-ALARM-MIB2 netiAlarmMIB2 ::= { netiExperimentalGeneric 8 } - deprecated
|
||||
-- NETI-IPOD-MIB netiIpodMIB ::= { netiExperimentalGeneric 9 } - deprecated
|
||||
-- NETI-ENTITY-MIB netiEntityMIB ::= { netiExperimentalGeneric 10 } - deprecated
|
||||
-- NETI-ETS-MIB netiEtsMIB ::= { netiExperimentalGeneric 11 } - deprecated
|
||||
-- NETI-ETHCONF-MIB netiEthConfMIB ::= { netiExperimentalGeneric 12 } - deprecated
|
||||
-- NETI-PACKW-MIB netiPackWMIB ::= { netiExperimentalGeneric 13 } - deprecated
|
||||
-- NETI-CHMGR-MIB netiChmgrMIB ::= { netiExperimentalGeneric 14 }
|
||||
-- NETI-DLT-MIB netiDltMIB ::= { netiExperimentalGeneric 15 } - deprecated
|
||||
-- NETI-ITS-MIB netiItsMIB ::= { netiExperimentalGeneric 16 }
|
||||
-- NETI-PM-MIB netiPMMIB ::= { netiExperimentalGeneric 17 }
|
||||
|
||||
netiExperimental OBJECT IDENTIFIER ::= {netinsight 6}
|
||||
netiExperimentalReg OBJECT IDENTIFIER ::= {netiExperimental 1}
|
||||
netiExperimentalGeneric OBJECT IDENTIFIER ::= {netiExperimental 2}
|
||||
netiExperimentalProducts OBJECT IDENTIFIER ::= {netiExperimental 3}
|
||||
netiExperimentalCaps OBJECT IDENTIFIER ::= {netiExperimental 4}
|
||||
netiExperimentalReqs OBJECT IDENTIFIER ::= {netiExperimental 5}
|
||||
|
||||
END
|