NETGEAR-POWER-ETHERNET-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- Copyright Netgear Inc (2003-2015) All rights reserved.
|
||||
|
||||
-- This SNMP Management Information Specification
|
||||
-- embodies Netgear Inc's confidential and proprietary
|
||||
-- intellectual property. Netgear Inc retains all title
|
||||
-- and ownership in the Specification including any revisions.
|
||||
|
||||
-- This Specification is supplied "AS IS", Netgear Inc
|
||||
-- makes no warranty, either expressed or implied,
|
||||
-- as to the use, operation, condition, or performance of the
|
||||
-- Specification.
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32 FROM SNMPv2-SMI
|
||||
TruthValue FROM SNMPv2-TC
|
||||
ng7000managedswitch FROM NETGEAR-REF-MIB
|
||||
DisplayString FROM RFC1213-MIB
|
||||
pethPsePortEntry, pethMainPseEntry FROM POWER-ETHERNET-MIB;
|
||||
|
||||
|
||||
fastPathpowerEthernetMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "201803020000Z" -- 02 Mar 2018 12:00:00 GMT
|
||||
ORGANIZATION "Netgear Inc"
|
||||
CONTACT-INFO ""
|
||||
|
||||
DESCRIPTION
|
||||
"This MIB Augments the POWER-ETHERNET-MIB created by the IETF Ethernet
|
||||
Interfaces and Hub MIB Working Group for managing Power Source
|
||||
Equipment (PSE). The objects in this MIB are intended to provide
|
||||
additional objects for reporting information available to the hardware
|
||||
on this platform which are not represented in the draft MIB."
|
||||
|
||||
-- Revision history.
|
||||
REVISION
|
||||
"201803020000Z" -- 02 Mar 2018 12:00:00 GMT
|
||||
DESCRIPTION
|
||||
"Deprecated agentPethPoeMainPseThresholdPower and
|
||||
agentPethPoeMainPseUsageThreshold objects from
|
||||
agentPethPoeMainPseObjects group as threshold
|
||||
should be maintained for unit (system) instead of per slot.
|
||||
Threshold Power is not present in agentPethPseTable, hence
|
||||
added agentPethPseThresholdPower in agentPethPseTable."
|
||||
REVISION
|
||||
"201801250000Z" -- 25 Jan 2018 12:00:00 GMT
|
||||
DESCRIPTION
|
||||
"agentPethPoeMainPseObjects Group is added to get/set the
|
||||
PoE System Data for all slots in a unit."
|
||||
REVISION
|
||||
"201503130000Z" -- 13 Mar 2015 12:00:00 GMT
|
||||
DESCRIPTION
|
||||
"agentPethPsePowerManagementMode object description is updated."
|
||||
REVISION
|
||||
"201404160000Z" -- 16 Apr 2014 12:00:00 GMT
|
||||
DESCRIPTION
|
||||
"Upoe support added in new object agentPethHighPowerMode."
|
||||
REVISION
|
||||
"201101260000Z" -- 26 Jan 2011 12:00:00 GMT
|
||||
DESCRIPTION
|
||||
"Postal address updated."
|
||||
REVISION
|
||||
"200708191200Z" -- 17 Aug 2007 12:00:00 GMT
|
||||
DESCRIPTION
|
||||
"PoE support for BCM59101 added."
|
||||
REVISION
|
||||
"200705230000Z" -- 23 May 2007 12:00:00 GMT
|
||||
DESCRIPTION
|
||||
"Netgear branding related changes."
|
||||
REVISION
|
||||
"200311101200Z" -- 10 Nov 2003 12:00:00 GMT
|
||||
DESCRIPTION
|
||||
"Initial revision."
|
||||
::= { ng7000managedswitch 15 }
|
||||
|
||||
agentPethObjects OBJECT IDENTIFIER ::= { fastPathpowerEthernetMIB 1 }
|
||||
|
||||
agentPethPsePortTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AgentPethPsePortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table of per-port information and configuration objects relating
|
||||
to the power status of each port."
|
||||
::= { agentPethObjects 1 }
|
||||
|
||||
agentPethPsePortEntry OBJECT-TYPE
|
||||
SYNTAX AgentPethPsePortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects providing additional power information
|
||||
and control parameters for the specified port."
|
||||
AUGMENTS { pethPsePortEntry }
|
||||
::= { agentPethPsePortTable 1 }
|
||||
|
||||
AgentPethPsePortEntry ::= SEQUENCE {
|
||||
agentPethPowerLimit
|
||||
Gauge32,
|
||||
agentPethOutputPower
|
||||
Gauge32,
|
||||
agentPethOutputCurrent
|
||||
Gauge32,
|
||||
agentPethOutputVolts
|
||||
Gauge32,
|
||||
agentPethTemperature
|
||||
Gauge32,
|
||||
agentPethPowerLimitType
|
||||
INTEGER,
|
||||
agentPethHighPowerEnable
|
||||
TruthValue,
|
||||
agentPethPowerDetectionType
|
||||
INTEGER,
|
||||
agentPethFaultStatus
|
||||
INTEGER,
|
||||
agentPethPortReset
|
||||
INTEGER,
|
||||
agentPethPowerLimitMin
|
||||
Gauge32,
|
||||
agentPethPowerLimitMax
|
||||
Gauge32
|
||||
}
|
||||
|
||||
agentPethPowerLimit OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
UNITS "Milliwatts"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The configured maximum power this port can provide to an
|
||||
attached device measured in Milliwatts."
|
||||
::= { agentPethPsePortEntry 1 }
|
||||
|
||||
agentPethOutputPower OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
UNITS "Milliwatts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The power this port is supplying to an attached device measured
|
||||
in Milliwatts."
|
||||
::= { agentPethPsePortEntry 2 }
|
||||
|
||||
agentPethOutputCurrent OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
UNITS "Milliamps"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current this port is supplying to an attached device measured
|
||||
in Milliamps."
|
||||
::= { agentPethPsePortEntry 3 }
|
||||
|
||||
agentPethOutputVolts OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
UNITS "Volts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The voltage this port is supplying to an attached device measured
|
||||
in Volts."
|
||||
::= { agentPethPsePortEntry 4 }
|
||||
|
||||
agentPethTemperature OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
UNITS "DEGREES"
|
||||
MAX-ACCESS read-only
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"The temperature measured at this port of the PoE Controller. It is
|
||||
measured in degree celcius."
|
||||
::= { agentPethPsePortEntry 5 }
|
||||
|
||||
agentPethPowerLimitType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
dot3af(1),
|
||||
user(2),
|
||||
none(3)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Describes or controls the maximum power that a port can deliver.
|
||||
A value of dot3af(1) means that the port power limit is as per
|
||||
the dot3af class of the PD attached.
|
||||
A value of user(2) means that the port power limit is equal to the value
|
||||
specified by agentPethPowerLimit"
|
||||
REFERENCE
|
||||
"Broadcom 5910X programmers guide, IEEE Std 802.3af Section 30.9.1.1.6"
|
||||
::= { agentPethPsePortEntry 6 }
|
||||
|
||||
agentPethHighPowerEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"true (1) The PSE port can deliver power up to 32Watts.
|
||||
false(2) The PSE port can deliver power up to 18Watts"
|
||||
REFERENCE
|
||||
"Broadcom 5910X programmers guide"
|
||||
|
||||
::= { agentPethPsePortEntry 7 }
|
||||
|
||||
agentPethPowerDetectionType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(0),
|
||||
legacy(1),
|
||||
fourPtdot3afonly(2),
|
||||
fourPtdot3afandlegacy(3),
|
||||
twoPtdot3afonly(4),
|
||||
twoPtdot3afandlegacy(5)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Describes PD detection mechanism performed by the PSE port.
|
||||
A value of none(0) means no detection is done.
|
||||
A value of legacy(1) means only legacy capacitive detection scheme is
|
||||
used.
|
||||
A value of 4ptdot3afonly(2) means that IEEE 802.3af 4point detection scheme
|
||||
is used.
|
||||
A value of 4ptdot3afandlegacy(3) means that IEEE 802.3af 4point detection scheme
|
||||
is used and when that fails to detect a connected PD, legacity capacitive detection
|
||||
is used.
|
||||
A value of 2ptdot3afonly(4) means that IEEE 802.3af 2point detection scheme
|
||||
is used.
|
||||
A value of 2ptdot3afandlegacy(5)means that IEEE 802.3af 2point detection scheme
|
||||
is used and when that fails to detect a connected PD, legacity capacitive detection
|
||||
is used.
|
||||
The value 'none' can not be forcibly set by the administrator."
|
||||
REFERENCE
|
||||
"Broadcom 5910X programmers guide, IEEE Std 802.3af Section 30.9.1.1.6"
|
||||
::= { agentPethPsePortEntry 8 }
|
||||
|
||||
agentPethFaultStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(0),
|
||||
mpsAbsent(1),
|
||||
short(2),
|
||||
overload(3),
|
||||
powerDenied(4),
|
||||
thermalShutdown(5),
|
||||
startupFailure(6)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Describes the error description when the pse port is in fault status.
|
||||
A value of none(0) specifies that the pse port is not in any error state.
|
||||
A value of mpsAbsent(1) specifies that the pse port has detected and absence
|
||||
of main power supply.
|
||||
A value of short(2) specifies that the pse port has detected a short circuit
|
||||
condition.
|
||||
A value of overload(3) specifies that the pd connected to the pse port had tried
|
||||
to draw more power than permissible by the hardware.
|
||||
A value of powerDenied(4) specifies that the pse port has been denied power
|
||||
because of shortage of power or due to administrative action.
|
||||
A value of thermalShutdown(5) specifies that the thermal threshold has exceeded
|
||||
for the pse port.
|
||||
A value of startupFailure(6) as fault status indicates that the port does not have
|
||||
sufficient voltage."
|
||||
REFERENCE
|
||||
"Broadcom 5910X programmers guide, IEEE Std 802.3af"
|
||||
|
||||
::= { agentPethPsePortEntry 9 }
|
||||
|
||||
agentPethPortReset OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(0),
|
||||
reset(1)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A value of reset(1) is used to move the pse port dot3af state to idle. A
|
||||
read on this object will always return the value none(0). The value none(0)
|
||||
can not be forcibly set by the administrtor."
|
||||
REFERENCE
|
||||
"Broadcom 5910X programmers guide, IEEE Std 802.3af"
|
||||
::= { agentPethPsePortEntry 10 }
|
||||
|
||||
agentPethPowerLimitMin OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
UNITS "Milliwatts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The minimum power this port can be configured to provide, measured in Milliwatts."
|
||||
::= { agentPethPsePortEntry 11 }
|
||||
|
||||
agentPethPowerLimitMax OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
UNITS "Milliwatts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The maximum power this port can be configured to provide, measured in Milliwatts."
|
||||
::= { agentPethPsePortEntry 12 }
|
||||
|
||||
|
||||
-- Main objects
|
||||
agentPethMainPseObjects OBJECT IDENTIFIER ::= { agentPethObjects 2 }
|
||||
|
||||
agentPethMainPseTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AgentPethMainPseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table of objects that display and control attributes
|
||||
of the main power source in a PSE device. Ethernet
|
||||
switches are one example of boxes that would support
|
||||
these objects.
|
||||
Values of all read-write objects in this table are
|
||||
persistent at restart/reboot."
|
||||
::= { agentPethMainPseObjects 1 }
|
||||
|
||||
agentPethMainPseEntry OBJECT-TYPE
|
||||
SYNTAX AgentPethMainPseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A set of objects that display and control the Main
|
||||
power of a PSE. "
|
||||
AUGMENTS { pethMainPseEntry }
|
||||
::= { agentPethMainPseTable 1 }
|
||||
|
||||
AgentPethMainPseEntry ::= SEQUENCE {
|
||||
agentPethMainPseLegacy
|
||||
TruthValue
|
||||
}
|
||||
|
||||
agentPethMainPseLegacy OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable/Disable Legacy device detection. The
|
||||
value true(1) means legacy devices are detected; the
|
||||
value false(2) means legacy devices are not detected."
|
||||
::= { agentPethMainPseEntry 1 }
|
||||
|
||||
agentPethPseTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AgentPethPseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table of per-unit information and configuration objects relating
|
||||
to the power configurtion for the entire pse unit."
|
||||
::= { agentPethObjects 3 }
|
||||
|
||||
agentPethPseEntry OBJECT-TYPE
|
||||
SYNTAX AgentPethPseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects providing additional power information
|
||||
and control parameters for the specified pse unit."
|
||||
AUGMENTS { pethMainPseEntry }
|
||||
::= { agentPethPseTable 1 }
|
||||
|
||||
AgentPethPseEntry ::= SEQUENCE {
|
||||
agentPethPsePowerManagementMode
|
||||
|
||||
INTEGER
|
||||
,
|
||||
agentPethPseThresholdPower
|
||||
Gauge32
|
||||
}
|
||||
|
||||
agentPethPsePowerManagementMode OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(0),
|
||||
dynamic(1),
|
||||
static(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Describes or controls the power management algorithm used by the pse
|
||||
to deliver power to the requesting PDsthat a pds.
|
||||
A value of dynamic(1) means that power consumption of each port
|
||||
is measured and calculated in real-time.
|
||||
A value of static(2) means that power allocated for each port depends
|
||||
on the type of power threshold configured on the port."
|
||||
REFERENCE
|
||||
"Broadcom 5910X programmers guide"
|
||||
|
||||
::= { agentPethPseEntry 1 }
|
||||
|
||||
agentPethPseThresholdPower OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
UNITS "Watts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Measured usage power expressed in Watts."
|
||||
::= { agentPethPseEntry 6 }
|
||||
|
||||
agentPethPoeMainPseObjects OBJECT IDENTIFIER ::= { agentPethObjects 4 }
|
||||
agentPethPoeMainPseTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AgentPethPoeMainPseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table of objects that display and control attributes
|
||||
of the main power source in a PSE device. Ethernet
|
||||
switches are one example of boxes that would support
|
||||
these objects.
|
||||
Values of all read-write objects in this table are
|
||||
persistent at restart/reboot."
|
||||
::= { agentPethPoeMainPseObjects 1 }
|
||||
|
||||
agentPethPoeMainPseEntry OBJECT-TYPE
|
||||
SYNTAX AgentPethPoeMainPseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A set of objects that display and control the Main
|
||||
power of a PSE. "
|
||||
INDEX { agentPethPoeMainPseGroupIndex, agentPethPoeMainPseSlotIndex }
|
||||
::= { agentPethPoeMainPseTable 1 }
|
||||
|
||||
AgentPethPoeMainPseEntry ::= SEQUENCE {
|
||||
agentPethPoeMainPseGroupIndex
|
||||
Integer32,
|
||||
agentPethPoeMainPseSlotIndex
|
||||
Integer32,
|
||||
agentPethPoeMainPsePower
|
||||
Gauge32,
|
||||
agentPethPoeMainPseOperStatus
|
||||
INTEGER,
|
||||
agentPethPoeMainPseThresholdPower
|
||||
Gauge32,
|
||||
agentPethPoeMainPseConsumptionPower
|
||||
Gauge32,
|
||||
agentPethPoeMainPseUsageThreshold
|
||||
Integer32,
|
||||
agentPethPoeMainPseFWImageVersion
|
||||
OCTET STRING,
|
||||
agentPethPoePsePowerManagementMode
|
||||
INTEGER,
|
||||
agentPethPoePseCardModel
|
||||
DisplayString,
|
||||
agentPethPoePseCardHost
|
||||
DisplayString,
|
||||
agentPethPoePseCardStatus
|
||||
INTEGER
|
||||
}
|
||||
agentPethPoeMainPseGroupIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable uniquely identifies the group to which
|
||||
power Ethernet PSE is connected. Group means (box in
|
||||
the stack, module in a rack) and the value 1 MUST be
|
||||
used for non-modular devices. Furthermore, the same
|
||||
value MUST be used in this variable, pethPsePortGroupIndex,
|
||||
and pethNotificationControlGroupIndex to refer to a
|
||||
given box in a stack or module in a rack."
|
||||
::= { agentPethPoeMainPseEntry 1 }
|
||||
|
||||
agentPethPoeMainPseSlotIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable uniquely identifies the slot in an unit."
|
||||
::= { agentPethPoeMainPseEntry 2 }
|
||||
|
||||
agentPethPoeMainPsePower OBJECT-TYPE
|
||||
SYNTAX Gauge32 (1..65535)
|
||||
UNITS "Watts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The nominal power of the PSE expressed in Watts."
|
||||
::= { agentPethPoeMainPseEntry 3 }
|
||||
|
||||
agentPethPoeMainPseOperStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
on(1),
|
||||
off(2),
|
||||
faulty(3)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The operational status of the main PSE."
|
||||
::= { agentPethPoeMainPseEntry 4 }
|
||||
|
||||
agentPethPoeMainPseThresholdPower OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
UNITS "Watts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"Measured usage power expressed in Watts. This object is deprecated as
|
||||
per slot Threshold is no longer supported"
|
||||
::= { agentPethPoeMainPseEntry 5 }
|
||||
|
||||
agentPethPoeMainPseConsumptionPower OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
UNITS "Milliwatts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Measured usage power expressed in Watts."
|
||||
::= { agentPethPoeMainPseEntry 6 }
|
||||
|
||||
agentPethPoeMainPseUsageThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..99)
|
||||
UNITS "%"
|
||||
MAX-ACCESS read-write
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"The usage threshold expressed in percents for
|
||||
comparing the measured power and initiating
|
||||
an alarm if the threshold is exceeded. This
|
||||
object is deprecated as per slot Usage Threshold
|
||||
is no longer supported."
|
||||
::= { agentPethPoeMainPseEntry 7 }
|
||||
|
||||
agentPethPoeMainPseFWImageVersion OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(256))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Version of the PoE controller's FW image."
|
||||
::= { agentPethPoeMainPseEntry 8 }
|
||||
|
||||
agentPethPoePsePowerManagementMode OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(0),
|
||||
dynamic(1),
|
||||
static(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Describes or controls the power management algorithm used by the pse
|
||||
to deliver power to the requesting PDs. A value of dynamic(1)
|
||||
means that power consumption of each port is measured and calculated in
|
||||
real-time. A value of static(2) means that power allocated for each port
|
||||
depends on the type of power threshold configured on the port."
|
||||
REFERENCE
|
||||
"Broadcom 5910X programmers guide"
|
||||
::= { agentPethPoeMainPseEntry 9 }
|
||||
|
||||
agentPethPoePseCardModel OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(1..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Displays the PoE daughther card model at PSE side."
|
||||
::= { agentPethPoeMainPseEntry 10 }
|
||||
|
||||
agentPethPoePseCardHost OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(1..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Displays the board which hosts the PoE daughther card at PSE side."
|
||||
::= { agentPethPoeMainPseEntry 11 }
|
||||
|
||||
agentPethPoePseCardStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
absent-or-failed(0),
|
||||
running(1)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Displays running status of the PoE daughther card at PSE side. The value
|
||||
absent-or-failed(0) means that the card is either not present or some error
|
||||
has occurred. The value running(1) means that card is present and working fine."
|
||||
::= { agentPethPoeMainPseEntry 12 }
|
||||
|
||||
END
|