@ -0,0 +1,78 @@
|
||||
MELLANOX-POWER-CYCLE-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
NOTIFICATION-TYPE, MODULE-IDENTITY, OBJECT-TYPE, Integer32
|
||||
FROM SNMPv2-SMI
|
||||
mellanoxPowerCycle
|
||||
FROM MELLANOX-SMI-MIB;
|
||||
|
||||
-- Mellanox Power Cycle MIB
|
||||
|
||||
mellanoxPowerCycleMib MODULE-IDENTITY
|
||||
LAST-UPDATED "201806040000Z"
|
||||
ORGANIZATION
|
||||
"Mellanox Technologies, Inc."
|
||||
CONTACT-INFO
|
||||
"
|
||||
Mellanox Technologies, Inc.
|
||||
350 Oakmead Parkway, Suite 100
|
||||
Sunnyvale, CA 94085
|
||||
Tel: 408-970-3400
|
||||
Fax: 408-970-3403
|
||||
E-mail: info@mellanox.com
|
||||
"
|
||||
DESCRIPTION
|
||||
"Mellanox PowerCycle MIB"
|
||||
|
||||
REVISION "201806040000Z"
|
||||
DESCRIPTION
|
||||
"Added planned reload traps"
|
||||
::= { mellanoxPowerCycle 1 }
|
||||
|
||||
mellanoxPowerCycleMibObjects OBJECT IDENTIFIER ::= { mellanoxPowerCycleMib 1 }
|
||||
|
||||
mellanoxPowerCycleCmd OBJECT IDENTIFIER ::= { mellanoxPowerCycleMibObjects 2 }
|
||||
|
||||
mellanoxPowerCycleNotifications OBJECT IDENTIFIER ::= { mellanoxPowerCycleMibObjects 3 }
|
||||
|
||||
mellanoxPowerCycleCmdExecute OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
mellanoxPowerCycleCmdExecuteReload (1),
|
||||
mellanoxPowerCycleCmdExecuteReloadDiscard (2),
|
||||
mellanoxPowerCycleCmdExecuteReloadForce (3),
|
||||
mellanoxPowerCycleCmdExecuteReloadSlave (4)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The operation to execute
|
||||
Setting this value will initiate the operation"
|
||||
::= { mellanoxPowerCycleCmd 1 }
|
||||
|
||||
mellanoxPowerCycleCmdStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The status of the operation:
|
||||
0: No operation
|
||||
1-100: progress percentage
|
||||
101: success
|
||||
>200: failure"
|
||||
::= { mellanoxPowerCycleCmd 2 }
|
||||
|
||||
mellanoxPowerCycleCmdStatusString OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"String value describing the operation status or error"
|
||||
::= { mellanoxPowerCycleCmd 3 }
|
||||
|
||||
mellanoxPowerCyclePlannedReload NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Device has resumed after a planned reload operation"
|
||||
::= { mellanoxPowerCycleNotifications 1 }
|
||||
|
||||
END
|