initial commit; version 22.5.12042
This commit is contained in:
382
mibs/intel/INTEL-COMMON-BMC-MIB
Executable file
382
mibs/intel/INTEL-COMMON-BMC-MIB
Executable file
@ -0,0 +1,382 @@
|
||||
--/******************************************************************************
|
||||
--*
|
||||
--* INTEL CORPORATION PROPRIETARY INFORMATION
|
||||
--* This software is supplied under the terms of a license agreement or
|
||||
--* nondisclosure agreement with Intel Corporation and may not be copied
|
||||
--* or disclosed except in accordance with the terms of that agreement.
|
||||
--* Copyright (c) 2001 Intel Corporation. All Rights Reserved.
|
||||
--*
|
||||
--*
|
||||
--******************************************************************************/
|
||||
|
||||
--/******************************************************************************
|
||||
-- *
|
||||
-- * Revision History:
|
||||
-- *
|
||||
-- * GAE - 01/24/11 Timer Expired watchdog 2, Power supply presence,
|
||||
-- * Power unit, SMI timeout, Drive slot.
|
||||
-- * GAE - 03/24/09 Changed "Thurley" to "Common."
|
||||
-- * edy - 10/13/08 removed unneeded variables
|
||||
-- *
|
||||
-- *****************************************************************************/
|
||||
|
||||
INTEL-COMMON-BMC-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- Title : BMC 1.0 MIB file.
|
||||
|
||||
IMPORTS
|
||||
enterprises
|
||||
FROM RFC1155-SMI
|
||||
TRAP-TYPE
|
||||
FROM RFC-1215;
|
||||
|
||||
-- textual conventions
|
||||
-- MODULE IDENTIFICATION
|
||||
--
|
||||
-- COMMENT: module-identity, last-updated, etc are MIB keywords, but are v2
|
||||
-- BMC Alerting MODULE-IDENTITY
|
||||
-- LAST-UPDATED "January 24, 2011"
|
||||
-- ORGANIZATION "Intel Corporation"
|
||||
-- CONTACT-INFO
|
||||
-- " Server Management Firmware Development,
|
||||
-- Intel Corporation, JF5
|
||||
-- Hillsboro, OR 97124"
|
||||
-- DESCRIPTION
|
||||
-- "This is the MIB file for the Embedded Server Management SNMP Agent."
|
||||
|
||||
wired-for-management OBJECT IDENTIFIER ::= {enterprises 3183}
|
||||
pet OBJECT IDENTIFIER ::= {wired-for-management 1}
|
||||
--**************************************************************************
|
||||
--* Notifications (using SNMPv1 TRAP-TYPE constructs for maximum
|
||||
--* compatibility with deployed SNMP managers).
|
||||
--**************************************************************************
|
||||
|
||||
pet-events OBJECT IDENTIFIER ::= {pet 1}
|
||||
--**************************************************************************
|
||||
-- Temperature Sensor Events (2 of them)
|
||||
--**************************************************************************
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (010107h == 65799)
|
||||
tempUpperNonCriticalGoingHigh TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Temperature sensor crossed upper non-critical threshold, going high."
|
||||
::= 65799
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (010109h == 65801)
|
||||
tempUpperCriticalGoingHigh TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Temperature sensor crossed upper critical threshold, going high."
|
||||
::= 65801
|
||||
|
||||
|
||||
--**************************************************************************
|
||||
-- Voltage Sensor Events (4 of them)
|
||||
--**************************************************************************
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (020100h == 131328)
|
||||
voltageLowerNonCriticalGoingLow TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Voltage sensor crossed lower non-critical threshold, going low."
|
||||
|
||||
::= 131328
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (020102h == 131330)
|
||||
voltageLowerCriticalGoingLow TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Voltage sensor crossed lower critical threshold, going low."
|
||||
::= 131330
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (020107h == 131335)
|
||||
voltageUpperNonCriticalGoingHigh TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Voltage sensor crossed upper non-critical threshold, going high."
|
||||
::= 131335
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (020109h == 131337)
|
||||
voltageUpperCriticalGoingHigh TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Voltage sensor crossed upper critical threshold, going high."
|
||||
::= 131337
|
||||
|
||||
|
||||
--**************************************************************************
|
||||
-- Fan Failure Events (2 of them)
|
||||
--**************************************************************************
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (040100h == 262400)
|
||||
fanFailureLowerNonCriticalGoingLow TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Fan sensor crossed lower non-critical threshold, going low."
|
||||
::= 262400
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (040102h == 262402)
|
||||
fanFailureLowerCriticalGoingLow TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Fan sensor crossed lower critical threshold, going low."
|
||||
|
||||
::= 262402
|
||||
|
||||
|
||||
--**************************************************************************
|
||||
-- Chassis Intrusion Event
|
||||
--**************************************************************************
|
||||
|
||||
-- Event Sensor Type 05h, Event Type 6fh, Event Offset 00h (056f00h == 356096)
|
||||
chassisIntrusionEvent TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"A Chassis Intrusion assertion event."
|
||||
|
||||
::= 356096
|
||||
|
||||
-- Event Sensor Type 05h, Event Type 6fh, Event Offset 04h (056f04h == 356100)
|
||||
chassisIntrusionEventLANLeashLost TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"A Chassis Intrusion LAN leash lost assertion event."
|
||||
|
||||
::= 356100
|
||||
--**************************************************************************
|
||||
-- Power Supply Fault Events (5 of them)
|
||||
--**************************************************************************
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (086F00h == 552704)
|
||||
powerSupplyPresence TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Power supply presence event."
|
||||
::= 552704
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (086F01h == 552705)
|
||||
powerSupplyFailure TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Power supply failure event."
|
||||
::= 552705
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (086F02h == 552706)
|
||||
powerSupplyPredictiveFailure TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Power supply predictive failure asserted event."
|
||||
::= 552706
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (086F03h == 552707)
|
||||
powerSupplyACLost TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Power supply A/C lost event."
|
||||
::= 552707
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (086F06h == 552710)
|
||||
powerSupplyConfigurationError TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Power supply configuration error event."
|
||||
::= 552710
|
||||
|
||||
--**************************************************************************
|
||||
-- Uncorrectable ECC Error Event
|
||||
--**************************************************************************
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (0C6F01h == 814849)
|
||||
uncorrectableECCError TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Uncorrectable ECC error event."
|
||||
|
||||
::= 814849
|
||||
|
||||
--**************************************************************************
|
||||
-- POST Error Event
|
||||
--**************************************************************************
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (0F6F00h == 1011456)
|
||||
postError TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Power On Self Test (POST) error event."
|
||||
|
||||
::= 1011456
|
||||
|
||||
--**************************************************************************
|
||||
-- Processor Failure Events (4 of them)
|
||||
--**************************************************************************
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (076F01h == 487169)
|
||||
thermalTripError TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Thermal Trip error event."
|
||||
::= 487169
|
||||
|
||||
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (076F07h == 487175)
|
||||
cpuPresence TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Processor Presence"
|
||||
|
||||
::= 487175
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (070301h == 459521)
|
||||
procDisabledError TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"CATERR Event Detected."
|
||||
::= 459521
|
||||
|
||||
--**************************************************************************
|
||||
-- Critical Interrupt Events (1 of them)
|
||||
--**************************************************************************
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (136F00h == 1273600)
|
||||
fatalNMIError TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Front Panel NMI Assertion event."
|
||||
::= 1273600
|
||||
|
||||
--**************************************************************************
|
||||
-- Watchdog 2 Events (5 of them)
|
||||
--**************************************************************************
|
||||
-- Event Sensor Type, Event Type, Event Offset (236F00h == 2322176)
|
||||
timerExpired TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Timer expired event."
|
||||
::= 2322176
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (236F01h == 2322177)
|
||||
hardReset TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Hard reset event."
|
||||
::= 2322177
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (236F02h == 2322178)
|
||||
powerDown TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Power down event."
|
||||
::= 2322178
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (236F03h == 2322179)
|
||||
powerReset TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Power Reset event"
|
||||
::= 2322179
|
||||
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (236F08h == 2322184)
|
||||
timerInterrupt TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Timer Interrupt event."
|
||||
::= 2322184
|
||||
|
||||
--**************************************************************************
|
||||
-- System Event
|
||||
--**************************************************************************
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (126F01h == 1208065)
|
||||
oemSystemBootEvent TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"OEM System Boot event."
|
||||
::= 1208065
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (106F02h == 1076994)
|
||||
selLogAreaReset TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Log area reset / cleared"
|
||||
::=1076994
|
||||
|
||||
|
||||
--**************************************************************************
|
||||
-- SMI Timeout
|
||||
--**************************************************************************
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (03F301h == 258817)
|
||||
smiTimeoutError TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"SMI Timeout Assertion event."
|
||||
::= 258817
|
||||
|
||||
--**************************************************************************
|
||||
-- Drive Slot (Bay) Offsets (4)
|
||||
--**************************************************************************
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (0D6F00h == 880384)
|
||||
drivePresence TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Drive Presence event."
|
||||
::= 880384
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (0D6F01h == 880385)
|
||||
driveFault TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Drive Fault event."
|
||||
::= 880385
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (0D6F02h == 880386)
|
||||
drivePredictiveFailure TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Drive Predictive Failure event."
|
||||
::= 880386
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (0D6F07h == 880391)
|
||||
driveRebuild TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Drive Rebuild event."
|
||||
::= 880391
|
||||
|
||||
--**************************************************************************
|
||||
-- Power Unit Offsets (4)
|
||||
--**************************************************************************
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (096F00h == 618240)
|
||||
powerOffPowerUnit TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Power Unit Power Off event."
|
||||
::= 618240
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (096F04h == 618244)
|
||||
acLostPowerUnit TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Power Unit AC Lost event."
|
||||
::= 618244
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (096F05h == 618245)
|
||||
softPowerControlPowerUnit TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Power Unit Soft Power Control Failure event."
|
||||
::= 618245
|
||||
|
||||
-- Event Sensor Type, Event Type, Event Offset (096F06h == 618246)
|
||||
powerUnitFailure TRAP-TYPE
|
||||
ENTERPRISE pet-events
|
||||
DESCRIPTION
|
||||
"Power Unit Failure event."
|
||||
::= 618246
|
||||
|
||||
END
|
1529
mibs/intel/INTEL-LAN-ADAPTERS-MIB
Normal file
1529
mibs/intel/INTEL-LAN-ADAPTERS-MIB
Normal file
File diff suppressed because it is too large
Load Diff
3717
mibs/intel/INTEL-SERVER-BASEBOARD7
Executable file
3717
mibs/intel/INTEL-SERVER-BASEBOARD7
Executable file
File diff suppressed because it is too large
Load Diff
Reference in New Issue
Block a user